Datasets:

ArXiv:
License:
File size: 3,969 Bytes
bc70d9d
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
---
pretty_name: "OpenH-RF — Technion Phantom Pre-Beamformed Channel Data"
license: cc-by-4.0
task_categories:
  - image-to-image
tags:
  - ultrasound
  - iq
  - openh-rf
  - beamforming
  - phantom
  - 3d
language:
  - en
size_categories:
  - n<1K
---

# OpenH-RF — Tissue-mimicking phantom pre-beamformed RF channel data

## Dataset Description

Pre-beamformed ultrasound **channel data** from a tissue-mimicking phantom,
acquired on the same 64-element phased-array sector scheme as the in-vivo
collection (180 transmit beams steered over ±45.13°, one image line per
transmit), for **calibration and verification**. Contains
resolvable point targets and an anechoic cyst — a clean reference for validating
beamforming and reconstruction. 12 frames, one acquisition.

## Dataset Contributor(s)

Sanketh Vedula, Ortal Senouf, Dean Zadok, Alex M. Bronstein (PI) —
Technion – Israel Institute of Technology. Primary contact: sanketh@campus.technion.ac.il.

## Dataset Creation Date

Source data 2018; converted to the OpenH-RF (zea) format 07/16/2026.

## License / Terms of Use

CC BY 4.0 (proposal §8).

## Intended Usage

Calibration and end-to-end verification of the beamforming/reconstruction
pipeline (point-target resolution, cyst contrast). Phantom tier (×1).

## Dataset Characterization

- **Data Collection Method:** phantom — tissue-mimicking phantom (Gammex 403GS LE,
  Gammex Inc., Middleton, WI, USA), acquired on the same scanner/probe as the
  in-vivo collection for calibration.
- **Labeling Method:** N/A (calibration target; known phantom geometry).
- **Acquisition system:** GE Vivid S70 scanner; GE 3Sc-RS 64-element phased-array
  probe, 0.30 mm pitch; sector scan, 180 transmit beams steered over ±45.13°
  (≈90.25° FOV), one image line per transmit; IQ demodulated at 3.44 MHz.

## Dataset Format

zea file format, a single HDF5 file `data/ph.hdf5`. Source complex samples
repackaged to `float32` I/Q (`n_ch = 2`), values verbatim. Carries
`metadata/subject/{id=ph, type=phantom}`, `metadata/credit`, probe model
(`probe.name = GE 3Sc-RS`) and scanner (`us_machine = GE Vivid S70`). ("phantom"
is recorded only as `subject.type`, not as an anatomy or label.)

## Dataset Quantification

**Current OpenH-RF release:** 1 HDF5 file; 659.95 MB (659,947,520 bytes) stored; root `zea_version` **0.1.4**. Sizes include all HDF5 contents and use decimal units (MB = 10^6 bytes, GB = 10^9 bytes, TB = 10^12 bytes), not decoded-array memory or original-source download sizes.

- **Frames / acquisitions:** 12 frames · 1 acquisition.
- **Stored HDF5 size:** 659.95 MB (659,947,520 bytes).

| Field | Shape | dtype | Units | Description |
|---|---|---|---|---|
| `data/raw_data` | `(12, 180, 696, 64, 2)` | float32 | a.u. | pre-BF channel IQ: frames × tx-lines × axial × elements × {I, Q} |
| `scan/sampling_frequency` | scalar | float32 | Hz | 3.333 MHz |
| `scan/center_frequency`, `demodulation_frequency` | scalar | float32 | Hz | 3.44 MHz |
| `scan/sound_speed` | scalar | float32 | m/s | 1540 |
| `scan/polar_angles` | `(180,)` | float32 | rad | ±45.13° steered lines |
| `probe/probe_geometry` | `(64, 3)` | float32 | m | element positions, 0.30 mm pitch |

## Subject Metadata

N/A — inanimate phantom (GAMMEX 403GS LE); `subject.type = phantom`.

## Data Validation

`reconstruct.py` reconstructs a B-mode from `raw_data` using the `zea.Pipeline`
in `pipeline.yaml` (delay-and-sum on a polar scanline grid → envelope →
normalization → log compression → sector scan conversion). Run:

```
python reconstruct.py data/ph.hdf5 --frame 6 --out bmode_ph.png
```

Reference output: `bmode_ph.png` — resolvable point targets and a well-defined
anechoic cyst at ~65 mm.

## Known Issues

- Same scan scheme and probe as the in-vivo bladder collection (GE
  tissue-harmonic); acquired as its calibration reference. GAMMEX 403GS LE.

## Ethical Considerations

None — inanimate phantom, no human or animal subjects.