File size: 6,056 Bytes
e610755 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 | ---
license: cc-by-nc-4.0
language:
- en
pretty_name: "Checking a Stereo Calibration on Ordinary Footage (Field Note #04)"
tags:
- robotics
- physical-ai
- egocentric
- stereo-vision
- camera-calibration
- fisheye
- epipolar-geometry
- kalibr
- opencv
- evaluation
task_categories:
- other
size_categories:
- n<1K
configs:
- config_name: default
data_files:
- split: train
path: data/evaluation_summary.csv
---
# Checking a Stereo Calibration on Ordinary Footage
**Origin Data Lab · Technical Field Note #04 · 23 October 2026**
[](https://origindatalab.io/technical-field-notes/stereo-calibration-check.html)


> **Short answer.** You can check whether a stereo calibration fits a device and capture mode using ordinary footage, without a target. On a 120 s, 1600×1200 head-mounted stereo recording, a Kalibr calibration from the same capture mode gave a **median angular epipolar error of 0.41 px** on 19,386 unfiltered matches; a calibration of the same camera family from a different (16:9) mode gave **1.83 px**. Two common checks can mislead on wide-angle lenses (see below).
**Code and issues:** [GitHub — origin-data-lab/stereo-calibration-validation](https://github.com/origin-data-lab/stereo-calibration-validation)
**Full article:** [Technical Field Note #04 — Checking a Stereo Calibration on Ordinary Footage](https://origindatalab.io/technical-field-notes/stereo-calibration-check.html)
---
## Key results
| Result | Value |
|---|---:|
| Median angular epipolar error, mode-matched calibration, no adjustment | **0.41 px** (19,386 matches, 29 frame pairs) |
| Same matches, calibration from a different capture mode | **1.83 px** |
| Stereo-rotation correction requested by the data | **< 0.02°** per axis |
| Deliberate 0.1° pitch error | median rises to **0.76 px** |
| Rectified vertical residual, 0–20° vs 75–90° field angle | **0.50 px → 4.05 px** (angular metric stays **0.46 px**) |
| `cv2.fisheye.undistortPoints` (OpenCV 5.0, defaults) | exact to ~**74°**; **4.5°** wrong at 80°, **8.0°** at 85° for this lens |
All values are from the evaluated recording and configuration; they are not universal guarantees.
## Two traps on wide-angle stereo
**1. Rectified vertical residuals inflate toward the image edge.** Projecting wide-angle rays onto a flat rectified image stretches the periphery (roughly 1/cos² of the angle), so a correct calibration looks wrong at the edges. Use an angular metric, or restrict rectified checks to the central field of view.
**2. OpenCV's default fisheye un-projection clamps the distorted angle at π/2.** With a positive k₁, θd reaches π/2 before the true ray angle reaches 90°, and every point beyond returns at the wrong angle. Run `tools/fisheye_roundtrip_check.py` with your own coefficients to see where this happens for your lens.
## Tools
```bash
pip install opencv-python numpy scipy pyyaml
# 1. Validate a Kalibr pinhole-equidistant stereo calibration on ordinary stereo footage
python tools/validate_stereo_calib.py --left left.mp4 --right right.mp4 \
--camchain camchain.yaml --scale 2 --out result.json
# --scale = video resolution / calibration resolution
# 2. Find where OpenCV's fisheye un-projection breaks for your coefficients
python tools/fisheye_roundtrip_check.py --camchain camchain.yaml --cam cam0 --scale 2
python tools/fisheye_roundtrip_check.py --k 0.12 0 0 0 --f 480 --cx 800 --cy 600
```
## Repository contents
| Path | Contents |
|---|---|
| `tools/validate_stereo_calib.py` | Target-free stereo calibration check (angular epipolar error, field-angle breakdown, held-out rotation fit) |
| `tools/fisheye_roundtrip_check.py` | OpenCV fisheye round-trip test |
| `results/` | Measured results behind the article (JSON) |
| `data/evaluation_summary.csv` | Key numbers as a table (shown in the Dataset Viewer) |
| `figures/` | Figures used in the article |
The device calibration parameters and the source recording are not published in this repository.
## What this check does not verify
- **Baseline length / metric scale** — absent from the epipolar constraint.
- **Metric depth accuracy** — requires targets at measured distances.
- **Camera–IMU calibration** — time shift and extrinsics need a separate test.
## Cite
```bibtex
@misc{origindatalab2026fieldnote04,
author = {{Origin Data Lab}},
title = {Checking a Stereo Calibration on Ordinary Footage},
howpublished = {Technical Field Note \#04},
year = {2026},
url = {https://origindatalab.io/technical-field-notes/stereo-calibration-check.html}
}
```
Or:
```
Origin Data Lab (2026). Checking a Stereo Calibration on Ordinary Footage. Technical Field Note #04.
https://origindatalab.io/technical-field-notes/stereo-calibration-check.html
```
## License
- Code in `tools/`: MIT
- Text, results and figures: [CC BY-NC 4.0](https://creativecommons.org/licenses/by-nc/4.0/) — free to share and adapt for non-commercial use with attribution to Origin Data Lab.
## Related
- [All Technical Field Notes](https://origindatalab.io/technical-field-notes/)
- [한국어 — 스테레오 캘리브레이션 검증 (Field Note #04)](https://origindatalab.io/ko/technical-field-notes/stereo-calibration-check.html)
- [#03 Stereo + IMU Egocentric Capture](https://origindatalab.io/technical-field-notes/stereo-imu-egocentric-sample.html) · [dataset card](https://huggingface.co/datasets/origindatalab/stereo-imu-egocentric-evaluation)
---
**Origin Data Lab** — real-world data production for Physical AI and robotics · [origindatalab.io](https://origindatalab.io) · [contact@origindatalab.io](mailto:contact@origindatalab.io)
Need per-device, per-capture-mode stereo calibration validated on your own footage? [Contact us](https://origindatalab.io/contact.html).
|