File size: 8,240 Bytes
91f5a2b
 
 
ed1c7c4
 
91f5a2b
 
ed1c7c4
91f5a2b
ed1c7c4
91f5a2b
 
 
ed1c7c4
91f5a2b
 
ed1c7c4
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
 
 
91f5a2b
ed1c7c4
 
 
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
 
 
 
 
 
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
 
 
 
 
91f5a2b
ed1c7c4
 
 
91f5a2b
ed1c7c4
 
 
 
 
 
91f5a2b
ed1c7c4
 
 
 
 
 
 
 
 
 
 
 
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
 
 
 
91f5a2b
ed1c7c4
 
 
 
91f5a2b
 
ed1c7c4
 
 
 
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
91f5a2b
ed1c7c4
 
 
 
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
91f5a2b
ed1c7c4
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
91f5a2b
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
 
 
 
91f5a2b
 
ed1c7c4
91f5a2b
ed1c7c4
 
 
 
 
91f5a2b
ed1c7c4
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
---
license: cc-by-4.0
pretty_name: AET-Bench
size_categories:
- n<1K
tags:
- atomic-electron-tomography
- electron-microscopy
- haadf-stem
- tomography
- 3d-reconstruction
- 4d-imaging
- materials-science
- benchmark
---

# AET-Bench: Pixel-Accurate Atomic Tomography Is Not Atom-Accurate

**NeurIPS 2026, Evaluations and Datasets Track**

Zicheng Liu<sup>1</sup>, Wenzhuo Ma<sup>2</sup>, Jintao Chen<sup>3</sup>, Di Huang<sup>1,2,4,5,\*</sup>

<sup>1</sup>BCC Lab, Hangzhou International Innovation Institute, Beihang University, Hangzhou, China<br>
<sup>2</sup>Shenzhen Loop Area Institute, Shenzhen, China<br>
<sup>3</sup>Zhejiang University, Hangzhou, China<br>
<sup>4</sup>Zhejiang Industrial Big Data and Robot Intelligent System Key Laboratory, Hangzhou Innovation Institute, Beihang University, Hangzhou, China<br>
<sup>5</sup>State Key Laboratory of Complex and Critical Software Environment, Beihang University, Beijing, China<br>
<sup>\*</sup>Corresponding author: Di Huang (dhuang@buaa.edu.cn)

[Paper (OpenReview)](https://openreview.net/forum?id=GmdQ25dIWq) ·
[Code (GitHub)](https://github.com/pone7/4D-ATE) ·
[Leaderboards](SUMMARY.md)

## Overview

Atomic electron tomography (AET) aims to recover the 3D positions, chemical
species, and temporal trajectories of individual atoms, yet reconstructions
are usually scored with voxel metrics such as PSNR, SSIM, and FSC. AET-Bench
is a dataset and benchmark for **atom-first** evaluation: it scores
reconstructions by the atoms, species, and trajectories scientists actually
use. On the Mono tier, the method with the best voxel similarity (MLEM, SSIM
0.946) is not the one that recovers the most atoms (FISTA-TV, 96.9% atom
recall at SSIM 0.506), and 4D Gaussian reconstructions with SSIM 0.94 keep
only about 15% of atom identities over time.

## Tiers

| Tier | Samples | Data | Reference | Evaluation focus |
|---|---|---|---|---|
| Mono | 410 (50 canonical) | Analytical HAADF-style projections, single-element FCC nanoparticles | Atom coordinates | Localization |
| Bi | 240 (30 canonical) | Analytical, binary-alloy nanoparticles | Coordinates + species | Chemistry |
| 4D | 10 | Time-varying Cu trajectories, 10 phases each | Coordinates + atom IDs | Trajectories, identity persistence |
| Multislice | 3 | abTEM multislice simulation (Cu, Pt) | Coordinates + species | Forward-model mismatch (pilot) |
| Real | 26 | Experimental tilt series from published records | Reference atom models | Reference agreement |
| Brownian-Pt | 66 | Dynamic Pt nanocrystal frames | Dynamic reference models | 4D tracking |

The paper's leaderboards use the canonical base samples of Mono and Bi; the
additional samples (ids with an `-sNN` suffix) are size and orientation
variants for development and ablation.

Each sample provides the tilt series, projection angles, physical calibration,
metadata, and the available references (volume, atom coordinates, species
labels, temporal identities). Within a tilt series, every seventh projection
is reserved for validation (60 fitting / 11 validation projections for a
71-angle series); there is no sample-level train/test split, because every
sample is an evaluation sample.

## Files

| File | Content |
|---|---|
| `aet-bench-<tier>.tar` / `.tar.part-NNN` | Tier archives (mono, bi, sim4d, multislice, real, brownian_pt) |
| `aet-bench-samples.csv` | One row per sample: tier, element, atom count, number of angles, paths inside the archive |
| `results.jsonl` | Full benchmark result log (one JSON row per method run) |
| `aet-bench-results.csv` | Flat CSV view of `results.jsonl` |
| `SUMMARY.md` | Leaderboards for every tier, computed with the paper's aggregation rules |
| `aet-bench-release-manifest.json` | File sizes and SHA256 for every uploaded file |
| `croissant.json` | Croissant 1.0 metadata with Responsible AI fields |
| `SHA256SUMS`, `ORIGINAL_ARCHIVE_SHA256SUMS` | Checksums of uploaded files and of reassembled archives |

### Reassembling split archives

Some tier archives are split into parts to keep individual Hub files below the
recommended size. Concatenate the parts in lexical order, check the SHA256,
then extract:

```bash
cat aet-bench-bi.tar.part-* > aet-bench-bi.tar
sha256sum aet-bench-bi.tar   # 6661b6b85c267e28010d479e854a95a84cf5bab8dde45cc0ed6a247b7a85b3e2
```

```bash
cat aet-bench-mono.tar.part-* > aet-bench-mono.tar
sha256sum aet-bench-mono.tar # 926adcfb2fc73c1d62b8c44befc9963540899f55a07669022da99c0376674602
```

```bash
cat aet-bench-real.tar.part-* > aet-bench-real.tar
sha256sum aet-bench-real.tar # 7e433949b0c53d739b594bf724d4505e7e348b7ca1113e0838da630ae242e43d
```

## Using the benchmark

The evaluation harness, method wrappers, and metrics are at
<https://github.com/pone7/4D-ATE>:

```bash
conda env create -f environment.yml && conda activate aet-bench
python scripts/run_benchmark.py --subset mono --sample Cu-0165-00 --method wbp --task T1
```

To reproduce the paper's tables and `SUMMARY.md` from `results.jsonl`:

```bash
python scripts/paper/aggregate_results.py --results results.jsonl --out paper_results.json
python scripts/paper/make_summary_md.py --agg paper_results.json --out SUMMARY.md
```

## Provenance

Simulated tiers (Mono, Bi, 4D, Multislice) are generated with ASE nanoparticle
construction, an analytical Z<sup>γ</sup> forward model, and abTEM multislice
simulation; the generating scripts are in the code repository. The Real tier is
converted from published experimental records:

| Source | DOI |
|---|---|
| Zr–ZrO₂ nanoparticles | [10.5281/zenodo.12742309](https://doi.org/10.5281/zenodo.12742309) |
| MPEA2 high-entropy alloy | [10.5281/zenodo.17310133](https://doi.org/10.5281/zenodo.17310133) |
| Pt Brownian tomography | [10.5281/zenodo.15531575](https://doi.org/10.5281/zenodo.15531575) |
| RESIRE datasets | [10.5281/zenodo.7819857](https://doi.org/10.5281/zenodo.7819857) |
| AlSiYb alloy | [10.5281/zenodo.2578866](https://doi.org/10.5281/zenodo.2578866) |
| PdPt core–shell (Zhou group) | [10.5281/zenodo.7733503](https://doi.org/10.5281/zenodo.7733503) |
| PdPt core–shell (Yang group) | [10.5281/zenodo.8245312](https://doi.org/10.5281/zenodo.8245312) |
| NiPt multi-grained catalyst | [10.5281/zenodo.15321070](https://doi.org/10.5281/zenodo.15321070) |
| AuPd icosahedral nanoparticles | [10.5281/zenodo.14677350](https://doi.org/10.5281/zenodo.14677350) |

The Brownian-Pt tier uses synthetic projections of published Pt
reconstructions. Please also cite the original records when you use the Real
or Brownian-Pt tiers.

## Limitations

* Real-tier scores measure agreement with experimentally derived reference
  models, not ground-truth accuracy; near-zero recall there is a
  reference-agreement failure, not proof that the atoms are unrecoverable.
* The Multislice tier has three samples and is a pilot: it supports a
  direction-of-effect claim, not a ranking.
* The analytical forward model does not capture dynamical scattering, and the
  data are biased toward inorganic metal and oxide nanoparticles imaged with
  HAADF-STEM.
* All public samples carry their references; a held-out private evaluation
  split for a public leaderboard is planned.

## Citation

```bibtex
@inproceedings{liu2026aetbench,
  title     = {{AET-Bench}: Pixel-Accurate Atomic Tomography Is Not Atom-Accurate},
  author    = {Liu, Zicheng and Ma, Wenzhuo and Chen, Jintao and Huang, Di},
  booktitle = {Advances in Neural Information Processing Systems (NeurIPS), Evaluations and Datasets Track},
  year      = {2026}
}
```

## License

The dataset is released under
[CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The code is released
under the MIT License.

## Acknowledgments

This research was supported by the Ningbo Science and Technology Project
(Grant No. 2025Z058), the Postdoctoral Innovative Talent Support Program of the
China Postdoctoral Science Foundation (Grant No. BX2026462), the China
Postdoctoral Science Foundation General Program (Grant No. 2026M794682), the
Priority-Funded Postdoctoral Research Project of Zhejiang Province (Grant No.
ZJ2026116), the Research Program of State Key Laboratory of Complex and
Critical Software Environment, and the Fundamental Research Funds for the
Central Universities.