referencesource commited on
Commit
d81ce10
·
verified ·
1 Parent(s): 9c77446

mirror of https://referencesource.org/ex-classification-system-crosswalk/

Browse files
Files changed (2) hide show
  1. README.md +3 -2
  2. data/records.jsonl +73 -10
README.md CHANGED
@@ -23,9 +23,9 @@ Machine-readable: https://referencesource.org/ex-classification-system-crosswalk
23
  - **Last verified:** 2026-08-06
24
  - **Stale after:** 2028-08-05 (past this date, prefer the canonical copy —
25
  it re-verifies on a cadence this snapshot does not)
26
- - **Records:** 65
27
 
28
- Crosswalk between the two concurrent hazardous-area classification systems: the North American Class / Division system of NEC Articles 500 and 505 (NFPA 70) and the CSA code, against the Zone system of IEC 60079, ATEX and IECEx. Each record is one designation in one system with its stated counterpart in the other, covering area classification (Division 1 and 2 against Zone 0, 1, 2, 20, 21, 22), gas groups (A, B, C, D against IIA, IIB, IIC, IIB+H2), dust groups (E, F, G against IIIA, IIIB, IIIC), protection concepts (explosion-proof against Ex d, intrinsically safe against Ex i, purged/pressurized against Ex p, dust-ignition-proof against Ex t, non-incendive against Ex nA/Ex ec) with the IEC standard number for each, and temperature codes T1 to T6 with their maximum surface temperatures. Answers 'is ATEX Ex d IIB T4 the same as Class I Div 1 Group C', 'what does T2D mean and is there an IEC equivalent', 'Division 1 or Zone 1 which is stricter', 'NEC Group B IEC equivalent', and 'can I install Zone 1 equipment in a Division 1 area'. Three things the mapping gets wrong when stated as a simple table: NEC 500 has no Zone 0 equivalent so Division 1 spans Zone 0 and Zone 1 and is under-specified for Zone 0; the North American temperature codes T2A, T2B, T2C, T2D, T3A, T3B, T3C and T4A have no IEC counterpart at all; and publishers disagree on NEC Group B, giving it as IIC or as IIB+H2, which changes the required flameproof gap. Every counterpart is quoted from the page that stated it and attributed, so the disagreement is visible.
29
 
30
  ## Provenance — what every record carries
31
 
@@ -45,6 +45,7 @@ fact plus a short attributed quote linking back to the page that states it.
45
  ## Sources
46
 
47
  - https://exknowledge.com/pages/nec-500-vs-atex-iec.html
 
48
  - https://www.inframena.com/hazardous-area-classification-equivalency-guide/
49
  - https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
50
  - https://ldpi-inc.com/resources/classification-codes/class-1-locations/
 
23
  - **Last verified:** 2026-08-06
24
  - **Stale after:** 2028-08-05 (past this date, prefer the canonical copy —
25
  it re-verifies on a cadence this snapshot does not)
26
+ - **Records:** 128
27
 
28
+ Crosswalk between the two concurrent hazardous-area classification systems: the North American Class / Division system of NEC Articles 500 and 505 (NFPA 70) and the CSA code, against the Zone system of IEC 60079, ATEX and IECEx. Each record is one designation in one system with its stated counterpart in the other, covering area classification (Division 1 and 2 against Zone 0, 1, 2, 20, 21, 22), gas groups (A, B, C, D against IIA, IIB, IIC, IIB+H2), dust groups (E, F, G against IIIA, IIIB, IIIC), protection concepts (explosion-proof against Ex d, intrinsically safe against Ex i, purged/pressurized against Ex p, dust-ignition-proof against Ex t, non-incendive against Ex nA/Ex ec) with the IEC standard number for each, and temperature codes T1 to T6 with their maximum surface temperatures. It also carries the equipment marking codes themselves -- the NEC 500 bracket codes (XP), (IS), (NI), (DIP), (PX), (PY), (PZ) and the NFPA 496 purge Types X, Y and Z, against the NEC 505 and CEC Ex / AEx codes -- each with the country whose column printed it, the hazard class and division or zone it is approved for, and the ISA, UL, FM, NFPA or CSA standard behind it, because the same code means different standards either side of the border: (IS) is UL 913 / FM 3610 in the US and C22.2 No. 157 in Canada. Answers 'is ATEX Ex d IIB T4 the same as Class I Div 1 Group C', 'what does T2D mean and is there an IEC equivalent', 'Division 1 or Zone 1 which is stricter', 'NEC Group B IEC equivalent', and 'can I install Zone 1 equipment in a Division 1 area'. Three things the mapping gets wrong when stated as a simple table: NEC 500 has no Zone 0 equivalent so Division 1 spans Zone 0 and Zone 1 and is under-specified for Zone 0; the North American temperature codes T2A, T2B, T2C, T2D, T3A, T3B, T3C and T4A have no IEC counterpart at all; and publishers disagree on NEC Group B, giving it as IIC or as IIB+H2, which changes the required flameproof gap. Every counterpart is quoted from the page that stated it and attributed, so the disagreement is visible.
29
 
30
  ## Provenance — what every record carries
31
 
 
45
  ## Sources
46
 
47
  - https://exknowledge.com/pages/nec-500-vs-atex-iec.html
48
+ - https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf
49
  - https://www.inframena.com/hazardous-area-classification-equivalency-guide/
50
  - https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups
51
  - https://ldpi-inc.com/resources/classification-codes/class-1-locations/
data/records.jsonl CHANGED
@@ -1,4 +1,25 @@
1
  {"basis": "Risk gradation", "category": "system attribute", "derived_fields": ["category"], "id": "3-levels-zone-0-1-2-system-attribute-2-levels-div-1-div-2", "iec_designation": "3 levels (Zone 0, 1, 2)", "north_american_designation": "2 levels (Div 1, Div 2)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Risk gradation | 2 levels (Div 1, Div 2) | 3 levels (Zone 0, 1, 2) | 3 levels (Zone 0, 1, 2)", "url": "https://referencesource.org/ex-classification-system-crosswalk/3-levels-zone-0-1-2-system-attribute-2-levels-div-1-div-2/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2
  {"basis": "Flammable gases and vapors", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-1-2-gas-area-classification-class-i", "iec_designation": "Zone 0, 1, 2 (gas)", "north_american_designation": "Class I", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Class I | Flammable gases and vapors", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-1-2-gas-area-classification-class-i/", "verified_fields": ["basis", "north_american_designation"]}
3
  {"basis": "Continuous hazard", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-area-classification-class-i-division-1", "iec_designation": "Zone 0", "north_american_designation": "Class I Division 1", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Continuous hazard | Class I Division 1 | Zone 0", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-area-classification-class-i-division-1/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
4
  {"basis": "Frequent hazard", "category": "area classification", "derived_fields": ["category"], "id": "zone-1-area-classification-class-i-division-1", "iec_designation": "Zone 1", "north_american_designation": "Class I Division 1", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Frequent hazard | Class I Division 1 | Zone 1", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-1-area-classification-class-i-division-1/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
@@ -14,12 +35,37 @@
14
  {"basis": "Grain, flour, plastic dusts", "category": "dust group", "derived_fields": ["category"], "id": "dust-group-class-ii-group-g", "north_american_designation": "Class II, Group G", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "Class II, Group G", "url": "https://referencesource.org/ex-classification-system-crosswalk/dust-group-class-ii-group-g/", "verified_fields": ["north_american_designation"]}
15
  {"basis": "Dust classification", "category": "system attribute", "derived_fields": ["category"], "id": "zone-20-21-22-iiia-iiib-iiic-system-attribute-class-ii-groups-e-f-g", "iec_designation": "Zone 20, 21, 22 (IIIA, IIIB, IIIC)", "north_american_designation": "Class II Groups E, F, G", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Dust classification | Class II Groups E, F, G | Not covered | Zone 20, 21, 22 (IIIA, IIIB, IIIC)", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-20-21-22-iiia-iiib-iiic-system-attribute-class-ii-groups-e-f-g/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
16
  {"basis": "Ignitable fibers", "category": "area classification", "derived_fields": ["category"], "id": "area-classification-class-iii", "north_american_designation": "Class III", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Class III | Ignitable fibers", "url": "https://referencesource.org/ex-classification-system-crosswalk/area-classification-class-iii/", "verified_fields": ["basis", "north_american_designation"]}
 
17
  {"basis": "Fibers and flyings", "category": "dust group", "derived_fields": ["category"], "id": "iiia-dust-group-class-iii", "iec_designation": "IIIA", "north_american_designation": "Class III", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "Gas / dust group | Typical Substances | IIC | Acetylene | Class I, Group A | Acetylene | IIB + H2 | Hydrogen | Class I, Group B | Hydrogen | IIB | Ethylene | Class I, Group C | Ethylene | IIA | Propane | Class I, Group D | Propane | IIIC | Conductive dust | Class II, Group E | Combustible metal dust | IIIB | Non-conductive dust | Class II, Group F | Combustible carbonaceous dust | Class II, Group G | Combustible dusts not in group E or F | IIIA | Combustible flyings | Class III |", "url": "https://referencesource.org/ex-classification-system-crosswalk/iiia-dust-group-class-iii/", "verified_fields": ["iec_designation", "north_american_designation"]}
 
 
 
 
18
  {"basis": "Hazard present during normal operation", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-zone-1-area-classification-division-1", "iec_designation": "Zone 0 / Zone 1", "north_american_designation": "Division 1", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Division 1 | Hazard present during normal operation", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-zone-1-area-classification-division-1/", "verified_fields": ["basis", "north_american_designation"]}
 
19
  {"basis": "Explosive atmosphere likely during normal operation (10–1000 hrs/yr)", "category": "area classification", "derived_fields": ["category"], "id": "zone-1-zone-0-area-classification-division-1", "iec_designation": "Zone 1 (+ Zone 0)", "north_american_designation": "Division 1", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Division 1 | Zone 1 (+ Zone 0) | Explosive atmosphere likely during normal operation (10–1000 hrs/yr)", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-1-zone-0-area-classification-division-1/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
 
 
20
  {"basis": "Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)", "category": "area classification", "derived_fields": ["category"], "disagreements": [{"field": "basis", "versions": [{"as_of": "2026-08-06", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Division 2 | Zone 2 | Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)", "value": "Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)"}, {"as_of": "2026-08-06", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Division 2 | Hazard present only under abnormal conditions", "value": "Hazard present only under abnormal conditions"}]}], "id": "zone-2-area-classification-division-2", "iec_designation": "Zone 2", "north_american_designation": "Division 2", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Division 2 | Zone 2 | Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-2-area-classification-division-2/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
 
21
  {"basis": "Prevent dust ingress and limit surface temperature", "category": "protection concept", "derived_fields": ["category"], "id": "ex-t-dust-protection-by-enclosure-protection-concept-dust-ignition-proof", "iec_designation": "Ex t (Dust protection by enclosure)", "iec_standard": "IEC 60079-31", "north_american_designation": "Dust-ignition-proof", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Dust-ignition-proof | Ex t (Dust protection by enclosure) | IEC 60079-31 | Prevent dust ingress and limit surface temperature", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-t-dust-protection-by-enclosure-protection-concept-dust-ignition-proof/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
22
  {"basis": "Encapsulation", "category": "protection concept", "derived_fields": ["category"], "id": "ex-m-protection-concept-encapsulation", "iec_designation": "Ex m", "north_american_designation": "Encapsulation", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex m | Encapsulation", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-m-protection-concept-encapsulation/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
23
  {"basis": "Contain the explosion inside the enclosure", "category": "protection concept", "derived_fields": ["category"], "id": "ex-d-flameproof-protection-concept-explosion-proof-xp", "iec_designation": "Ex d (Flameproof)", "iec_standard": "IEC 60079-1", "north_american_designation": "Explosion-proof (XP)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Explosion-proof (XP) | Ex d (Flameproof) | IEC 60079-1 | Contain the explosion inside the enclosure", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-d-flameproof-protection-concept-explosion-proof-xp/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
24
  {"basis": "Protection concept", "category": "system attribute", "derived_fields": ["category"], "id": "iec-aligned-types-ex-d-ex-i-ex-e-etc-system-attribute-explosion-proof-xp-intrinsically-safe-is", "iec_designation": "IEC-aligned types (Ex d, Ex i, Ex e, etc.)", "north_american_designation": "Explosion-proof (XP), intrinsically safe (IS)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Protection concept | Explosion-proof (XP), intrinsically safe (IS) | IEC-aligned types (Ex d, Ex i, etc.) | IEC-aligned types (Ex d, Ex i, Ex e, etc.)", "url": "https://referencesource.org/ex-classification-system-crosswalk/iec-aligned-types-ex-d-ex-i-ex-e-etc-system-attribute-explosion-proof-xp-intrinsically-safe-is/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
25
  {"basis": "Flameproof enclosure", "category": "protection concept", "derived_fields": ["category"], "id": "ex-d-protection-concept-flameproof-enclosure", "iec_designation": "Ex d", "north_american_designation": "Flameproof enclosure", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex d | Flameproof enclosure", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-d-protection-concept-flameproof-enclosure/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
@@ -27,28 +73,37 @@
27
  {"basis": "Hydrogen", "category": "gas group", "derived_fields": ["category"], "id": "iic-gas-group-group-b", "iec_designation": "IIC", "north_american_designation": "Group B", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "Hydrogen | B | 520 | 968 | 6,000 PSI | IIC", "url": "https://referencesource.org/ex-classification-system-crosswalk/iic-gas-group-group-b/", "verified_fields": ["basis", "iec_designation"]}
28
  {"basis": "MESG <0.50 mm", "category": "gas group", "derived_fields": ["category"], "id": "iic-partially-iib-h-gas-group-group-b", "iec_designation": "IIC (partially IIB+H₂)", "north_american_designation": "Group B", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "B | IIC (partially IIB+H₂) | Hydrogen, butadiene | <0.50 mm", "url": "https://referencesource.org/ex-classification-system-crosswalk/iic-partially-iib-h-gas-group-group-b/", "verified_fields": ["iec_designation"]}
29
  {"basis": "MESG 0.50–0.90 mm", "category": "gas group", "derived_fields": ["category"], "disagreements": [{"field": "basis", "versions": [{"as_of": "2026-08-06", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "C | IIB | Ethylene, ethyl ether | 0.50–0.90 mm", "value": "MESG 0.50–0.90 mm"}, {"as_of": "2026-08-06", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "Ethylene | C | 450 | 842 | 1,200 PSI | IIB", "value": "Ethylene"}]}], "id": "iib-gas-group-group-c", "iec_designation": "IIB", "north_american_designation": "Group C", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "C | IIB | Ethylene, ethyl ether | 0.50–0.90 mm", "url": "https://referencesource.org/ex-classification-system-crosswalk/iib-gas-group-group-c/", "verified_fields": ["iec_designation"]}
 
30
  {"basis": "MESG >0.90 mm", "category": "gas group", "derived_fields": ["category"], "disagreements": [{"field": "basis", "versions": [{"as_of": "2026-08-06", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "D | IIA | Methane, propane, gasoline | >0.90 mm", "value": "MESG >0.90 mm"}, {"as_of": "2026-08-06", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "Gasoline | D | 280 | 536 | 600 PSI | IIA", "value": "Gasoline"}, {"as_of": "2026-08-06", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "D (Propane) | IIA", "value": "Propane"}]}], "id": "iia-gas-group-group-d", "iec_designation": "IIA", "north_american_designation": "Group D", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "D | IIA | Methane, propane, gasoline | >0.90 mm", "url": "https://referencesource.org/ex-classification-system-crosswalk/iia-gas-group-group-d/", "verified_fields": ["iec_designation"]}
31
- {"basis": "Metal dust", "category": "gas group", "derived_fields": ["category"], "id": "gas-group-group-e", "north_american_designation": "Group E", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "E | Metal dust", "url": "https://referencesource.org/ex-classification-system-crosswalk/gas-group-group-e/", "verified_fields": ["basis"]}
32
- {"basis": "Carbon dust", "category": "gas group", "derived_fields": ["category"], "id": "gas-group-group-f", "north_american_designation": "Group F", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "F | Carbon dust", "url": "https://referencesource.org/ex-classification-system-crosswalk/gas-group-group-f/", "verified_fields": ["basis"]}
33
- {"basis": "Grain / flour dust", "category": "gas group", "derived_fields": ["category"], "id": "gas-group-group-g", "north_american_designation": "Group G", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "G | Grain / flour dust", "url": "https://referencesource.org/ex-classification-system-crosswalk/gas-group-group-g/", "verified_fields": ["basis"]}
34
  {"basis": "Gas classification", "category": "system attribute", "derived_fields": ["category"], "id": "groups-iic-iib-iia-system-attribute-groups-a-b-c-d", "iec_designation": "Groups IIC, IIB, IIA", "north_american_designation": "Groups A, B, C, D", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Gas classification | Groups A, B, C, D | Groups IIC, IIB, IIA | Groups IIC, IIB, IIA", "url": "https://referencesource.org/ex-classification-system-crosswalk/groups-iic-iib-iia-system-attribute-groups-a-b-c-d/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
35
  {"basis": "Seal ignition source from atmosphere", "category": "protection concept", "derived_fields": ["category"], "id": "ex-nc-ex-m-protection-concept-hermetically-sealed", "iec_designation": "Ex nC / Ex m", "iec_standard": "IEC 60079-15 / -18", "north_american_designation": "Hermetically sealed", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Hermetically sealed | Ex nC / Ex m | IEC 60079-15 / -18 | Seal ignition source from atmosphere", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-nc-ex-m-protection-concept-hermetically-sealed/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
36
  {"basis": "Increased safety", "category": "protection concept", "derived_fields": ["category"], "id": "ex-e-protection-concept-increased-safety", "iec_designation": "Ex e", "north_american_designation": "Increased safety", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex e | Increased safety", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-e-protection-concept-increased-safety/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
37
  {"basis": "Intrinsic safety", "category": "protection concept", "derived_fields": ["category"], "id": "ex-i-protection-concept-intrinsically-safe", "iec_designation": "Ex i", "north_american_designation": "Intrinsically Safe", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex i | Intrinsic safety", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-i-protection-concept-intrinsically-safe/", "verified_fields": ["basis", "iec_designation"]}
38
  {"basis": "Limit energy below ignition threshold", "category": "protection concept", "derived_fields": ["category"], "id": "ex-i-ex-ia-ex-ib-protection-concept-intrinsically-safe-is", "iec_designation": "Ex i (Ex ia, Ex ib)", "iec_standard": "IEC 60079-11", "north_american_designation": "Intrinsically Safe (IS)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Intrinsically Safe (IS) | Ex i (Ex ia, Ex ib) | IEC 60079-11 | Limit energy below ignition threshold", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-i-ex-ia-ex-ib-protection-concept-intrinsically-safe-is/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
 
 
 
 
 
 
39
  {"basis": "Geographic use: USA, Canada vs EU, UK, most of the world", "category": "system attribute", "derived_fields": ["category"], "id": "atex-iecex-zone-system-attribute-nec-500-class-division", "iec_designation": "ATEX / IECEx (Zone)", "north_american_designation": "NEC 500 (Class/Division)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Geographic use | USA, Canada | USA, Canada | EU, UK, most of the world", "url": "https://referencesource.org/ex-classification-system-crosswalk/atex-iecex-zone-system-attribute-nec-500-class-division/"}
40
  {"basis": "Legal framework", "category": "system attribute", "derived_fields": ["category"], "id": "eu-directive-2014-34-eu-iecex-scheme-system-attribute-nfpa-70-adopted-by-ahjs", "iec_designation": "EU Directive 2014/34/EU / IECEx scheme", "north_american_designation": "NFPA 70 (adopted by AHJs)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Legal framework | NFPA 70 (adopted by AHJs) | NFPA 70 (adopted by AHJs) | EU Directive 2014/34/EU / IECEx scheme", "url": "https://referencesource.org/ex-classification-system-crosswalk/eu-directive-2014-34-eu-iecex-scheme-system-attribute-nfpa-70-adopted-by-ahjs/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
41
- {"basis": "Explosive atmosphere continuously or for long periods (>1000 hrs/yr)", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-area-classification-no-nec-500-equivalent", "iec_designation": "Zone 0", "north_american_designation": "(no NEC 500 equivalent)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Zone 0 | Explosive atmosphere continuously or for long periods (>1000 hrs/yr)", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-area-classification-no-nec-500-equivalent/", "verified_fields": ["basis", "iec_designation"]}
42
- {"basis": "Explosive atmosphere present continuously or for long periods", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-area-classification-no-nec-equivalent", "iec_designation": "Zone 0", "north_american_designation": "(no NEC equivalent)", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Zone 0 | Explosive atmosphere present continuously or for long periods", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-area-classification-no-nec-equivalent/", "verified_fields": ["basis", "iec_designation"]}
43
- {"basis": "Explosive atmosphere likely during normal operation", "category": "area classification", "derived_fields": ["category"], "id": "zone-1-area-classification-no-nec-equivalent", "iec_designation": "Zone 1", "north_american_designation": "(no NEC equivalent)", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Zone 1 | Explosive atmosphere likely during normal operation", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-1-area-classification-no-nec-equivalent/", "verified_fields": ["basis", "iec_designation"]}
44
- {"basis": "Explosive atmosphere unlikely in normal operation, only short duration eg. accidental leakage", "category": "area classification", "derived_fields": ["category"], "id": "zone-2-area-classification-no-nec-equivalent", "iec_designation": "Zone 2", "north_american_designation": "(no NEC equivalent)", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Zone 2 | Explosive atmosphere unlikely in normal operation, only short duration eg. accidental leakage", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-2-area-classification-no-nec-equivalent/", "verified_fields": ["basis", "iec_designation"]}
45
- {"basis": "Combustible dust present continuously", "category": "area classification", "derived_fields": ["category"], "id": "zone-20-area-classification-no-nec-equivalent", "iec_designation": "Zone 20", "north_american_designation": "(no NEC equivalent)", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Zone 20 | Combustible dust present continuously", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-20-area-classification-no-nec-equivalent/", "verified_fields": ["basis", "iec_designation"]}
46
- {"basis": "Dust likely during normal operation", "category": "area classification", "derived_fields": ["category"], "id": "zone-21-area-classification-no-nec-equivalent", "iec_designation": "Zone 21", "north_american_designation": "(no NEC equivalent)", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Zone 21 | Dust likely during normal operation", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-21-area-classification-no-nec-equivalent/", "verified_fields": ["basis", "iec_designation"]}
47
- {"basis": "Dust unlikely except briefly", "category": "area classification", "derived_fields": ["category"], "id": "zone-22-area-classification-no-nec-equivalent", "iec_designation": "Zone 22", "north_american_designation": "(no NEC equivalent)", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Zone 22 | Dust unlikely except briefly", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-22-area-classification-no-nec-equivalent/", "verified_fields": ["basis", "iec_designation"]}
48
  {"basis": "Normal operation cannot cause ignition", "category": "protection concept", "derived_fields": ["category"], "id": "ex-na-ex-ec-protection-concept-non-incendive", "iec_designation": "Ex nA / Ex ec", "iec_standard": "IEC 60079-15 / -7", "north_american_designation": "Non-incendive", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Non-incendive | Ex nA / Ex ec | IEC 60079-15 / -7 | Normal operation cannot cause ignition", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-na-ex-ec-protection-concept-non-incendive/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
49
  {"basis": "Certification body", "category": "system attribute", "derived_fields": ["category"], "id": "notified-bodies-atex-excbs-iecex-system-attribute-nrtls-ul-fm-csa", "iec_designation": "Notified Bodies (ATEX) / ExCBs (IECEx)", "north_american_designation": "NRTLs (UL, FM, CSA)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Certification body | NRTLs (UL, FM, CSA) | NRTLs | Notified Bodies (ATEX) / ExCBs (IECEx)", "url": "https://referencesource.org/ex-classification-system-crosswalk/notified-bodies-atex-excbs-iecex-system-attribute-nrtls-ul-fm-csa/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
50
  {"basis": "Pressurization", "category": "protection concept", "derived_fields": ["category"], "id": "ex-p-protection-concept-pressurization", "iec_designation": "Ex p", "north_american_designation": "Pressurization", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex p | Pressurization", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-p-protection-concept-pressurization/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
51
  {"basis": "Maintain positive pressure with inert gas", "category": "protection concept", "derived_fields": ["category"], "id": "ex-p-ex-px-ex-py-ex-pz-protection-concept-purged-pressurized", "iec_designation": "Ex p (Ex px, Ex py, Ex pz)", "iec_standard": "IEC 60079-2", "north_american_designation": "Purged/Pressurized", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Purged/Pressurized | Ex p (Ex px, Ex py, Ex pz) | IEC 60079-2 | Maintain positive pressure with inert gas", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-p-ex-px-ex-py-ex-pz-protection-concept-purged-pressurized/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
 
 
 
 
 
 
52
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T1 | T1 | 450 | 842", "value": "842"}], "basis": "Ignition temperature of gas / dust >450", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t1-temperature-code-t1", "iec_designation": "T1", "max_surface_temperature_c": "450", "north_american_designation": "T1", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "450 | T1 | >450", "url": "https://referencesource.org/ex-classification-system-crosswalk/t1-temperature-code-t1/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
53
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2 | T2 | 300 | 572", "value": "572"}], "basis": "Ignition temperature of gas / dust >300-450", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t2-temperature-code-t2", "iec_designation": "T2", "max_surface_temperature_c": "300", "north_american_designation": "T2", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "300 | T2 | >300-450", "url": "https://referencesource.org/ex-classification-system-crosswalk/t2-temperature-code-t2/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
54
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2A | | 280 | 536", "value": "536"}], "basis": "Ignition temperature of gas / dust >280-300", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "temperature-code-t2a", "max_surface_temperature_c": "280", "north_american_designation": "T2A", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "280 | T2A | >280-300", "url": "https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t2a/", "verified_fields": ["max_surface_temperature_c", "north_american_designation"]}
@@ -63,3 +118,11 @@
63
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T4A | | 120 | 248", "value": "248"}], "basis": "Ignition temperature of gas / dust >120-135", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "temperature-code-t4a", "max_surface_temperature_c": "120", "north_american_designation": "T4A", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "120 | T4A | >120-135", "url": "https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t4a/", "verified_fields": ["max_surface_temperature_c", "north_american_designation"]}
64
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T5 | T5 | 100 | 212", "value": "212"}], "basis": "Ignition temperature of gas / dust >100-135", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t5-temperature-code-t5", "iec_designation": "T5", "max_surface_temperature_c": "100", "north_american_designation": "T5", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "100 | T5 | >100-135", "url": "https://referencesource.org/ex-classification-system-crosswalk/t5-temperature-code-t5/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
65
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T6 | T6 | 85 | 185", "value": "185"}], "basis": "Ignition temperature of gas / dust >85-100", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t6-temperature-code-t6", "iec_designation": "T6", "max_surface_temperature_c": "85", "north_american_designation": "T6", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "85 | T6 | >85-100", "url": "https://referencesource.org/ex-classification-system-crosswalk/t6-temperature-code-t6/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
 
 
 
 
 
 
 
 
 
1
  {"basis": "Risk gradation", "category": "system attribute", "derived_fields": ["category"], "id": "3-levels-zone-0-1-2-system-attribute-2-levels-div-1-div-2", "iec_designation": "3 levels (Zone 0, 1, 2)", "north_american_designation": "2 levels (Div 1, Div 2)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Risk gradation | 2 levels (Div 1, Div 2) | 3 levels (Zone 0, 1, 2) | 3 levels (Zone 0, 1, 2)", "url": "https://referencesource.org/ex-classification-system-crosswalk/3-levels-zone-0-1-2-system-attribute-2-levels-div-1-div-2/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
2
+ {"basis": "Flame Proof", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-d", "iec_standard": "ISA 60079-1", "north_american_designation": "AEx d", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Flame Proof AEx d US Class I Zone 1 ISA 60079-1", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-d/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
3
+ {"basis": "Increased Safety", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-e", "iec_standard": "ISA 60079-7", "north_american_designation": "AEx e", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Increased Safety AEx e US Class I Zone 1 ISA 60079-7", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-e/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
4
+ {"basis": "Intrinsic Safety", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 0", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-ia", "iec_standard": "ISA 60079-11", "north_american_designation": "AEx ia", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Intrinsic Safety AEx ia US Class I Zone 0 ISA 60079-11", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-ia/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
5
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 20", "id": "us-protection-concept-aex-iad", "iec_standard": "ISA 61241-11", "north_american_designation": "AEx iaD", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx iaD US Zone 20 ISA 61241-11", "url": "https://referencesource.org/ex-classification-system-crosswalk/us-protection-concept-aex-iad/", "verified_fields": ["country", "division_or_zone", "iec_standard", "north_american_designation"]}
6
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-ib", "iec_standard": "ISA 60079-11", "north_american_designation": "AEx ib", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx ib US Class I Zone 1 ISA 60079-11", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-ib/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
7
+ {"basis": "Intrinsic Safety", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 21", "id": "us-protection-concept-aex-ibd", "iec_standard": "ISA 61241-11", "north_american_designation": "AEx ibD", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Intrinsic Safety AEx ibD US Zone 21 ISA 61241-11", "url": "https://referencesource.org/ex-classification-system-crosswalk/us-protection-concept-aex-ibd/", "verified_fields": ["basis", "country", "division_or_zone", "iec_standard", "north_american_designation"]}
8
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-m", "iec_standard": "ISA 60079-18", "north_american_designation": "AEx m", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx m US Class I Zone 1 ISA 60079-18", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-m/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
9
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 0", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-ma", "iec_standard": "ISA 60079-18", "north_american_designation": "AEx ma", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx ma US Class I Zone 0 ISA 60079-18", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-ma/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
10
+ {"category": "protection concept", "derived_fields": ["category"], "division_or_zone": "Zone 20", "id": "protection-concept-aex-mad", "iec_standard": "ISA 61241-18", "north_american_designation": "AEx maD", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx maD Zone 20 ISA 61241-18", "url": "https://referencesource.org/ex-classification-system-crosswalk/protection-concept-aex-mad/", "verified_fields": ["division_or_zone", "iec_standard", "north_american_designation"]}
11
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-mb", "iec_standard": "ISA 60079-18", "north_american_designation": "AEx mb", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx mb US Class I Zone 1 ISA 60079-18", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-mb/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
12
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 21", "id": "us-protection-concept-aex-mbd", "iec_standard": "ISA 61241-18", "north_american_designation": "AEx mbD", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx mbD US Zone 21 ISA 61241-18", "url": "https://referencesource.org/ex-classification-system-crosswalk/us-protection-concept-aex-mbd/", "verified_fields": ["country", "division_or_zone", "iec_standard", "north_american_designation"]}
13
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-na", "iec_standard": "ISA 60079-15", "north_american_designation": "AEx nA", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx nA US Class I Zone 2 ISA 60079-15", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-na/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
14
+ {"basis": "Enclosed Break", "category": "protection concept", "country": "US", "derived_fields": ["category"], "disagreements": [], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-nc", "iec_standard": "ISA 60079-15", "north_american_designation": "AEx nC", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Enclosed Break AEx nC US Class I Zone 2 ISA 60079-15", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-nc/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
15
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-nr", "iec_standard": "ISA 60079-15", "north_american_designation": "AEx nR", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx nR US Class I Zone 2 ISA 60079-15", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-nr/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
16
+ {"basis": "Oil Emmersion", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-o", "iec_standard": "ISA 60079-6", "north_american_designation": "AEx o", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Oil Emmersion AEx o US Class I Zone 1 ISA 60079-6", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-o/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
17
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 21", "id": "us-protection-concept-aex-pd", "iec_standard": "ISA 61241-2", "north_american_designation": "AEx pD", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx pD US Zone 21 ISA 61241-2", "url": "https://referencesource.org/ex-classification-system-crosswalk/us-protection-concept-aex-pd/", "verified_fields": ["country", "division_or_zone", "iec_standard", "north_american_designation"]}
18
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-px", "iec_standard": "ISA 60079-2", "north_american_designation": "AEx px", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx px US Class I Zone 1 ISA 60079-2", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-px/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
19
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-py", "iec_standard": "ISA 60079-2", "north_american_designation": "AEx py", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx py US Class I Zone 1 ISA 60079-2", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-py/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
20
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-pz", "iec_standard": "ISA 60079-2", "north_american_designation": "AEx pz", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx pz US Class I Zone 2 ISA 60079-2", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-pz/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
21
+ {"basis": "Power Filled", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-aex-q", "iec_standard": "ISA 60079-5", "north_american_designation": "AEx q", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Power Filled AEx q US Class I Zone 1 ISA 60079-5", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-aex-q/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
22
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 21", "id": "us-protection-concept-aex-td", "iec_standard": "ISA 60079-31", "north_american_designation": "AEx tD", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "AEx tD US Zone 21 ISA 60079-31", "url": "https://referencesource.org/ex-classification-system-crosswalk/us-protection-concept-aex-td/", "verified_fields": ["country", "division_or_zone", "iec_standard", "north_american_designation"]}
23
  {"basis": "Flammable gases and vapors", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-1-2-gas-area-classification-class-i", "iec_designation": "Zone 0, 1, 2 (gas)", "north_american_designation": "Class I", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Class I | Flammable gases and vapors", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-1-2-gas-area-classification-class-i/", "verified_fields": ["basis", "north_american_designation"]}
24
  {"basis": "Continuous hazard", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-area-classification-class-i-division-1", "iec_designation": "Zone 0", "north_american_designation": "Class I Division 1", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Continuous hazard | Class I Division 1 | Zone 0", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-area-classification-class-i-division-1/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
25
  {"basis": "Frequent hazard", "category": "area classification", "derived_fields": ["category"], "id": "zone-1-area-classification-class-i-division-1", "iec_designation": "Zone 1", "north_american_designation": "Class I Division 1", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Frequent hazard | Class I Division 1 | Zone 1", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-1-area-classification-class-i-division-1/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
 
35
  {"basis": "Grain, flour, plastic dusts", "category": "dust group", "derived_fields": ["category"], "id": "dust-group-class-ii-group-g", "north_american_designation": "Class II, Group G", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "Class II, Group G", "url": "https://referencesource.org/ex-classification-system-crosswalk/dust-group-class-ii-group-g/", "verified_fields": ["north_american_designation"]}
36
  {"basis": "Dust classification", "category": "system attribute", "derived_fields": ["category"], "id": "zone-20-21-22-iiia-iiib-iiic-system-attribute-class-ii-groups-e-f-g", "iec_designation": "Zone 20, 21, 22 (IIIA, IIIB, IIIC)", "north_american_designation": "Class II Groups E, F, G", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Dust classification | Class II Groups E, F, G | Not covered | Zone 20, 21, 22 (IIIA, IIIB, IIIC)", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-20-21-22-iiia-iiib-iiic-system-attribute-class-ii-groups-e-f-g/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
37
  {"basis": "Ignitable fibers", "category": "area classification", "derived_fields": ["category"], "id": "area-classification-class-iii", "north_american_designation": "Class III", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Class III | Ignitable fibers", "url": "https://referencesource.org/ex-classification-system-crosswalk/area-classification-class-iii/", "verified_fields": ["basis", "north_american_designation"]}
38
+ {"basis": "IEC considers fibers within the dust framework", "category": "dust group", "derived_fields": ["category"], "id": "dust-group-class-iii", "north_american_designation": "Class III", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Fiber hazards: NEC Class III (fibers/flyings) has no IEC equivalent. IEC considers fibers within the dust framework.", "url": "https://referencesource.org/ex-classification-system-crosswalk/dust-group-class-iii/", "verified_fields": ["basis", "north_american_designation"]}
39
  {"basis": "Fibers and flyings", "category": "dust group", "derived_fields": ["category"], "id": "iiia-dust-group-class-iii", "iec_designation": "IIIA", "north_american_designation": "Class III", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "Gas / dust group | Typical Substances | IIC | Acetylene | Class I, Group A | Acetylene | IIB + H2 | Hydrogen | Class I, Group B | Hydrogen | IIB | Ethylene | Class I, Group C | Ethylene | IIA | Propane | Class I, Group D | Propane | IIIC | Conductive dust | Class II, Group E | Combustible metal dust | IIIB | Non-conductive dust | Class II, Group F | Combustible carbonaceous dust | Class II, Group G | Combustible dusts not in group E or F | IIIA | Combustible flyings | Class III |", "url": "https://referencesource.org/ex-classification-system-crosswalk/iiia-dust-group-class-iii/", "verified_fields": ["iec_designation", "north_american_designation"]}
40
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class II", "id": "class-ii-us-protection-concept-dip", "iec_standard": "UL 1203", "north_american_designation": "(DIP)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(DIP) US Class II Division 1 UL 1203", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-us-protection-concept-dip/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
41
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class II", "id": "class-ii-ca-protection-concept-dip-a21", "iec_standard": "CSA E61241-1-1", "north_american_designation": "(DIP) A21", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(DIP) A21 CA Class II Division 1 CSA E61241-1-1", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-ca-protection-concept-dip-a21/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
42
+ {"category": "protection concept", "derived_fields": ["category"], "division_or_zone": "Division 2", "id": "protection-concept-dip-a22", "iec_standard": "CSA E61241-1-1", "north_american_designation": "(DIP) A22", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(DIP) A22 Division 2 CSA E61241-1-1", "url": "https://referencesource.org/ex-classification-system-crosswalk/protection-concept-dip-a22/", "verified_fields": ["division_or_zone", "iec_standard", "north_american_designation"]}
43
+ {"basis": "Division 1 equipment generally satisfies Category 2", "category": "equipment category", "derived_fields": ["category"], "id": "category-2-equipment-category-division-1", "iec_designation": "Category 2", "north_american_designation": "Division 1", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Map existing equipment to ATEX categories (Division 1 equipment generally satisfies Category 2; Division 2 satisfies Category 3)", "url": "https://referencesource.org/ex-classification-system-crosswalk/category-2-equipment-category-division-1/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
44
  {"basis": "Hazard present during normal operation", "category": "area classification", "derived_fields": ["category"], "id": "zone-0-zone-1-area-classification-division-1", "iec_designation": "Zone 0 / Zone 1", "north_american_designation": "Division 1", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Division 1 | Hazard present during normal operation", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-zone-1-area-classification-division-1/", "verified_fields": ["basis", "north_american_designation"]}
45
+ {"category": "area classification", "derived_fields": ["category"], "id": "zone-0-zone-20-area-classification-division-1", "iec_designation": "Zone 0 / Zone 20", "north_american_designation": "Division 1", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Division 1 Zone 0 / Zone 20", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-0-zone-20-area-classification-division-1/", "verified_fields": ["iec_designation", "north_american_designation"]}
46
  {"basis": "Explosive atmosphere likely during normal operation (10–1000 hrs/yr)", "category": "area classification", "derived_fields": ["category"], "id": "zone-1-zone-0-area-classification-division-1", "iec_designation": "Zone 1 (+ Zone 0)", "north_american_designation": "Division 1", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Division 1 | Zone 1 (+ Zone 0) | Explosive atmosphere likely during normal operation (10–1000 hrs/yr)", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-1-zone-0-area-classification-division-1/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
47
+ {"category": "area classification", "derived_fields": ["category"], "id": "zone-1-zone-21-area-classification-division-1", "iec_designation": "Zone 1 / Zone 21", "north_american_designation": "Division 1", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Division 1 Zone 1 / Zone 21", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-1-zone-21-area-classification-division-1/", "verified_fields": ["iec_designation", "north_american_designation"]}
48
+ {"basis": "Division 2 satisfies Category 3", "category": "equipment category", "derived_fields": ["category"], "id": "category-3-equipment-category-division-2", "iec_designation": "Category 3", "north_american_designation": "Division 2", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Map existing equipment to ATEX categories (Division 1 equipment generally satisfies Category 2; Division 2 satisfies Category 3)", "url": "https://referencesource.org/ex-classification-system-crosswalk/category-3-equipment-category-division-2/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
49
  {"basis": "Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)", "category": "area classification", "derived_fields": ["category"], "disagreements": [{"field": "basis", "versions": [{"as_of": "2026-08-06", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Division 2 | Zone 2 | Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)", "value": "Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)"}, {"as_of": "2026-08-06", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Division 2 | Hazard present only under abnormal conditions", "value": "Hazard present only under abnormal conditions"}]}], "id": "zone-2-area-classification-division-2", "iec_designation": "Zone 2", "north_american_designation": "Division 2", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Division 2 | Zone 2 | Explosive atmosphere not likely; only abnormal conditions (<10 hrs/yr)", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-2-area-classification-division-2/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
50
+ {"category": "area classification", "derived_fields": ["category"], "id": "zone-2-zone-22-area-classification-division-2", "iec_designation": "Zone 2 / Zone 22", "north_american_designation": "Division 2", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Division 2 Zone 2 / Zone 22", "url": "https://referencesource.org/ex-classification-system-crosswalk/zone-2-zone-22-area-classification-division-2/", "verified_fields": ["iec_designation", "north_american_designation"]}
51
  {"basis": "Prevent dust ingress and limit surface temperature", "category": "protection concept", "derived_fields": ["category"], "id": "ex-t-dust-protection-by-enclosure-protection-concept-dust-ignition-proof", "iec_designation": "Ex t (Dust protection by enclosure)", "iec_standard": "IEC 60079-31", "north_american_designation": "Dust-ignition-proof", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Dust-ignition-proof | Ex t (Dust protection by enclosure) | IEC 60079-31 | Prevent dust ingress and limit surface temperature", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-t-dust-protection-by-enclosure-protection-concept-dust-ignition-proof/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
52
  {"basis": "Encapsulation", "category": "protection concept", "derived_fields": ["category"], "id": "ex-m-protection-concept-encapsulation", "iec_designation": "Ex m", "north_american_designation": "Encapsulation", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex m | Encapsulation", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-m-protection-concept-encapsulation/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
53
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1 & 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex", "iec_standard": "CSA 60079-0", "north_american_designation": "Ex", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex CA Class I Division 1 & 2 CSA 60079-0", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
54
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Zone 20, 21, 22", "id": "us-protection-concept-ex", "iec_standard": "ISA 60079-0", "north_american_designation": "Ex", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex US Zone 20, 21, 22 ISA 60079-0", "url": "https://referencesource.org/ex-classification-system-crosswalk/us-protection-concept-ex/", "verified_fields": ["country", "division_or_zone", "iec_standard", "north_american_designation"]}
55
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-d", "iec_standard": "CSA 60079-1", "north_american_designation": "Ex d", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex d CA Class I Zone 1 CSA 60079-1", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-d/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
56
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-e", "iec_standard": "CSA E60079-7", "north_american_designation": "Ex e", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex e CA Class I Zone 1 CSA E60079-7", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-e/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
57
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 0", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-ia", "iec_standard": "CSA E60079-11", "north_american_designation": "EX ia", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "EX ia CA Class I Zone 0 CSA E60079-11", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-ia/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
58
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-ib", "iec_standard": "CSA E60079-11", "north_american_designation": "Ex ib", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex ib CA Class I Zone 1 CSA E60079-11", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-ib/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
59
+ {"basis": "Encapsulated", "category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-m", "iec_standard": "CSA E60079-18", "north_american_designation": "Ex m", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Encapsulated Ex m CA Class I Zone 1 CSA E60079-18", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-m/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
60
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-na", "iec_standard": "CSA E60079-15", "north_american_designation": "EX nA", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "EX nA CA Class I Zone 2 CSA E60079-15", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-na/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
61
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-nc", "iec_standard": "CSA E60079-15", "north_american_designation": "Ex nC", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex nC CA Class I Zone 2 CSA E60079-15", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-nc/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
62
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-nl", "iec_standard": "CSA E60079-15", "north_american_designation": "Ex nL", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex nL CA Class I Zone 2 CSA E60079-15", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-nl/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
63
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-nr", "iec_standard": "CSA E60079-15", "north_american_designation": "Ex nR", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex nR CA Class I Zone 2 CSA E60079-15", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-nr/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
64
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-o", "iec_standard": "CSA E60079-6", "north_american_designation": "EX o", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "EX o CA Class I Zone 1 CSA E60079-6", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-o/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
65
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-px", "iec_standard": "CSA E60079-2", "north_american_designation": "Ex px", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex px CA Class I Zone 1 CSA E60079-2", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-px/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
66
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-py", "iec_standard": "CSA E60079-2", "north_american_designation": "Ex py", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex py CA Class I Zone 1 CSA E60079-2", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-py/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
67
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-pz", "iec_standard": "CSA E60079-2", "north_american_designation": "Ex pz", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex pz CA Class I Zone 2 CSA E60079-2", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-pz/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
68
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Zone 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ex-q", "iec_standard": "CSA E60079-5", "north_american_designation": "Ex q", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Ex q CA Class I Zone 1 CSA E60079-5", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ex-q/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
69
  {"basis": "Contain the explosion inside the enclosure", "category": "protection concept", "derived_fields": ["category"], "id": "ex-d-flameproof-protection-concept-explosion-proof-xp", "iec_designation": "Ex d (Flameproof)", "iec_standard": "IEC 60079-1", "north_american_designation": "Explosion-proof (XP)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Explosion-proof (XP) | Ex d (Flameproof) | IEC 60079-1 | Contain the explosion inside the enclosure", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-d-flameproof-protection-concept-explosion-proof-xp/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
70
  {"basis": "Protection concept", "category": "system attribute", "derived_fields": ["category"], "id": "iec-aligned-types-ex-d-ex-i-ex-e-etc-system-attribute-explosion-proof-xp-intrinsically-safe-is", "iec_designation": "IEC-aligned types (Ex d, Ex i, Ex e, etc.)", "north_american_designation": "Explosion-proof (XP), intrinsically safe (IS)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Protection concept | Explosion-proof (XP), intrinsically safe (IS) | IEC-aligned types (Ex d, Ex i, etc.) | IEC-aligned types (Ex d, Ex i, Ex e, etc.)", "url": "https://referencesource.org/ex-classification-system-crosswalk/iec-aligned-types-ex-d-ex-i-ex-e-etc-system-attribute-explosion-proof-xp-intrinsically-safe-is/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
71
  {"basis": "Flameproof enclosure", "category": "protection concept", "derived_fields": ["category"], "id": "ex-d-protection-concept-flameproof-enclosure", "iec_designation": "Ex d", "north_american_designation": "Flameproof enclosure", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex d | Flameproof enclosure", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-d-protection-concept-flameproof-enclosure/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
 
73
  {"basis": "Hydrogen", "category": "gas group", "derived_fields": ["category"], "id": "iic-gas-group-group-b", "iec_designation": "IIC", "north_american_designation": "Group B", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "Hydrogen | B | 520 | 968 | 6,000 PSI | IIC", "url": "https://referencesource.org/ex-classification-system-crosswalk/iic-gas-group-group-b/", "verified_fields": ["basis", "iec_designation"]}
74
  {"basis": "MESG <0.50 mm", "category": "gas group", "derived_fields": ["category"], "id": "iic-partially-iib-h-gas-group-group-b", "iec_designation": "IIC (partially IIB+H₂)", "north_american_designation": "Group B", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "B | IIC (partially IIB+H₂) | Hydrogen, butadiene | <0.50 mm", "url": "https://referencesource.org/ex-classification-system-crosswalk/iic-partially-iib-h-gas-group-group-b/", "verified_fields": ["iec_designation"]}
75
  {"basis": "MESG 0.50–0.90 mm", "category": "gas group", "derived_fields": ["category"], "disagreements": [{"field": "basis", "versions": [{"as_of": "2026-08-06", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "C | IIB | Ethylene, ethyl ether | 0.50–0.90 mm", "value": "MESG 0.50–0.90 mm"}, {"as_of": "2026-08-06", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "Ethylene | C | 450 | 842 | 1,200 PSI | IIB", "value": "Ethylene"}]}], "id": "iib-gas-group-group-c", "iec_designation": "IIB", "north_american_designation": "Group C", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "C | IIB | Ethylene, ethyl ether | 0.50–0.90 mm", "url": "https://referencesource.org/ex-classification-system-crosswalk/iib-gas-group-group-c/", "verified_fields": ["iec_designation"]}
76
+ {"basis": "Methane (mining)", "category": "gas group", "derived_fields": ["category"], "id": "gas-group-group-d", "north_american_designation": "Group D", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Methane (mining) Group D", "url": "https://referencesource.org/ex-classification-system-crosswalk/gas-group-group-d/", "verified_fields": ["basis", "north_american_designation"]}
77
  {"basis": "MESG >0.90 mm", "category": "gas group", "derived_fields": ["category"], "disagreements": [{"field": "basis", "versions": [{"as_of": "2026-08-06", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "D | IIA | Methane, propane, gasoline | >0.90 mm", "value": "MESG >0.90 mm"}, {"as_of": "2026-08-06", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "Gasoline | D | 280 | 536 | 600 PSI | IIA", "value": "Gasoline"}, {"as_of": "2026-08-06", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "D (Propane) | IIA", "value": "Propane"}]}], "id": "iia-gas-group-group-d", "iec_designation": "IIA", "north_american_designation": "Group D", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "D | IIA | Methane, propane, gasoline | >0.90 mm", "url": "https://referencesource.org/ex-classification-system-crosswalk/iia-gas-group-group-d/", "verified_fields": ["iec_designation"]}
78
+ {"basis": "Combustible Metal Dusts", "category": "dust group", "derived_fields": ["category"], "disagreements": [{"field": "basis", "versions": [{"as_of": "2026-10-06", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Combustible Metal Dusts Group E", "value": "Combustible Metal Dusts"}, {"as_of": "2026-10-06", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "E | Metal dust", "value": "Metal dust"}]}], "id": "dust-group-group-e", "north_american_designation": "Group E", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Combustible Metal Dusts Group E", "url": "https://referencesource.org/ex-classification-system-crosswalk/dust-group-group-e/", "verified_fields": ["basis", "north_american_designation"]}
79
+ {"basis": "Carbon dust", "category": "dust group", "derived_fields": ["category"], "disagreements": [], "id": "dust-group-group-f", "north_american_designation": "Group F", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "F | Carbon dust", "url": "https://referencesource.org/ex-classification-system-crosswalk/dust-group-group-f/", "verified_fields": ["basis"]}
80
+ {"basis": "Grain / flour dust", "category": "dust group", "derived_fields": ["category"], "id": "dust-group-group-g", "north_american_designation": "Group G", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "G | Grain / flour dust", "url": "https://referencesource.org/ex-classification-system-crosswalk/dust-group-group-g/", "verified_fields": ["basis"]}
81
  {"basis": "Gas classification", "category": "system attribute", "derived_fields": ["category"], "id": "groups-iic-iib-iia-system-attribute-groups-a-b-c-d", "iec_designation": "Groups IIC, IIB, IIA", "north_american_designation": "Groups A, B, C, D", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Gas classification | Groups A, B, C, D | Groups IIC, IIB, IIA | Groups IIC, IIB, IIA", "url": "https://referencesource.org/ex-classification-system-crosswalk/groups-iic-iib-iia-system-attribute-groups-a-b-c-d/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
82
  {"basis": "Seal ignition source from atmosphere", "category": "protection concept", "derived_fields": ["category"], "id": "ex-nc-ex-m-protection-concept-hermetically-sealed", "iec_designation": "Ex nC / Ex m", "iec_standard": "IEC 60079-15 / -18", "north_american_designation": "Hermetically sealed", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Hermetically sealed | Ex nC / Ex m | IEC 60079-15 / -18 | Seal ignition source from atmosphere", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-nc-ex-m-protection-concept-hermetically-sealed/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
83
  {"basis": "Increased safety", "category": "protection concept", "derived_fields": ["category"], "id": "ex-e-protection-concept-increased-safety", "iec_designation": "Ex e", "north_american_designation": "Increased safety", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex e | Increased safety", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-e-protection-concept-increased-safety/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
84
  {"basis": "Intrinsic safety", "category": "protection concept", "derived_fields": ["category"], "id": "ex-i-protection-concept-intrinsically-safe", "iec_designation": "Ex i", "north_american_designation": "Intrinsically Safe", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex i | Intrinsic safety", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-i-protection-concept-intrinsically-safe/", "verified_fields": ["basis", "iec_designation"]}
85
  {"basis": "Limit energy below ignition threshold", "category": "protection concept", "derived_fields": ["category"], "id": "ex-i-ex-ia-ex-ib-protection-concept-intrinsically-safe-is", "iec_designation": "Ex i (Ex ia, Ex ib)", "iec_standard": "IEC 60079-11", "north_american_designation": "Intrinsically Safe (IS)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Intrinsically Safe (IS) | Ex i (Ex ia, Ex ib) | IEC 60079-11 | Limit energy below ignition threshold", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-i-ex-ia-ex-ib-protection-concept-intrinsically-safe-is/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
86
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-is", "iec_standard": "C22.2 No. 157", "north_american_designation": "(IS)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(IS) CA Class I Division 1 C22.2 No. 157", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-is/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
87
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-is", "iec_standard": "UL 913 / FM 3610", "north_american_designation": "(IS)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(IS) US Class I Division 1 UL 913 / FM 3610", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-is/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
88
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class II", "id": "class-ii-ca-protection-concept-is", "iec_standard": "CSA C22.2 No. 157", "north_american_designation": "(IS)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(IS) CA Class II Division 1 CSA C22.2 No. 157", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-ca-protection-concept-is/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
89
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class II", "id": "class-ii-us-protection-concept-is", "iec_standard": "UL 913 / FM 3610", "north_american_designation": "(IS)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(IS) US Class II Division 1 UL 913 / FM 3610", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-us-protection-concept-is/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
90
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class III", "id": "class-iii-ca-protection-concept-is", "iec_standard": "CSA C22.2 No. 157", "north_american_designation": "(IS)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(IS) CA Class III Division 1 CSA C22.2 No. 157", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-iii-ca-protection-concept-is/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
91
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class III", "id": "class-iii-us-protection-concept-is", "iec_standard": "UL 913 / FM 3610", "north_american_designation": "(IS)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(IS) US Class III Division 1 UL 913 / FM 3610", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-iii-us-protection-concept-is/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
92
  {"basis": "Geographic use: USA, Canada vs EU, UK, most of the world", "category": "system attribute", "derived_fields": ["category"], "id": "atex-iecex-zone-system-attribute-nec-500-class-division", "iec_designation": "ATEX / IECEx (Zone)", "north_american_designation": "NEC 500 (Class/Division)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Geographic use | USA, Canada | USA, Canada | EU, UK, most of the world", "url": "https://referencesource.org/ex-classification-system-crosswalk/atex-iecex-zone-system-attribute-nec-500-class-division/"}
93
  {"basis": "Legal framework", "category": "system attribute", "derived_fields": ["category"], "id": "eu-directive-2014-34-eu-iecex-scheme-system-attribute-nfpa-70-adopted-by-ahjs", "iec_designation": "EU Directive 2014/34/EU / IECEx scheme", "north_american_designation": "NFPA 70 (adopted by AHJs)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Legal framework | NFPA 70 (adopted by AHJs) | NFPA 70 (adopted by AHJs) | EU Directive 2014/34/EU / IECEx scheme", "url": "https://referencesource.org/ex-classification-system-crosswalk/eu-directive-2014-34-eu-iecex-scheme-system-attribute-nfpa-70-adopted-by-ahjs/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
94
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-ni", "iec_standard": "C22.2 No. 213", "north_american_designation": "(NI)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(NI) CA Class I Division 2 C22.2 No. 213", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-ni/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
95
+ {"basis": "Non-Incendive", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 2", "hazard_class": "Class I", "id": "class-i-us-protection-concept-ni", "iec_standard": "ISA 12.12.01/FM 3611", "north_american_designation": "(NI)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Non-Incendive (NI) US Class I Division 2 ISA 12.12.01/FM 3611", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-ni/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
96
+ {"basis": "Dust Protected", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 2", "hazard_class": "Class II", "id": "class-ii-us-protection-concept-ni", "iec_standard": "ISA 12.12.01 / FM 3611", "north_american_designation": "(NI)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Dust Protected (NI) US Class II Division 2 ISA 12.12.01 / FM 3611", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-us-protection-concept-ni/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
 
 
 
 
97
  {"basis": "Normal operation cannot cause ignition", "category": "protection concept", "derived_fields": ["category"], "id": "ex-na-ex-ec-protection-concept-non-incendive", "iec_designation": "Ex nA / Ex ec", "iec_standard": "IEC 60079-15 / -7", "north_american_designation": "Non-incendive", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Non-incendive | Ex nA / Ex ec | IEC 60079-15 / -7 | Normal operation cannot cause ignition", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-na-ex-ec-protection-concept-non-incendive/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
98
  {"basis": "Certification body", "category": "system attribute", "derived_fields": ["category"], "id": "notified-bodies-atex-excbs-iecex-system-attribute-nrtls-ul-fm-csa", "iec_designation": "Notified Bodies (ATEX) / ExCBs (IECEx)", "north_american_designation": "NRTLs (UL, FM, CSA)", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Certification body | NRTLs (UL, FM, CSA) | NRTLs | Notified Bodies (ATEX) / ExCBs (IECEx)", "url": "https://referencesource.org/ex-classification-system-crosswalk/notified-bodies-atex-excbs-iecex-system-attribute-nrtls-ul-fm-csa/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
99
  {"basis": "Pressurization", "category": "protection concept", "derived_fields": ["category"], "id": "ex-p-protection-concept-pressurization", "iec_designation": "Ex p", "north_american_designation": "Pressurization", "source": "https://www.inframena.com/hazardous-area-classification-equivalency-guide/", "source_quote": "Ex p | Pressurization", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-p-protection-concept-pressurization/", "verified_fields": ["basis", "iec_designation", "north_american_designation"]}
100
  {"basis": "Maintain positive pressure with inert gas", "category": "protection concept", "derived_fields": ["category"], "id": "ex-p-ex-px-ex-py-ex-pz-protection-concept-purged-pressurized", "iec_designation": "Ex p (Ex px, Ex py, Ex pz)", "iec_standard": "IEC 60079-2", "north_american_designation": "Purged/Pressurized", "source": "https://exknowledge.com/pages/nec-500-vs-atex-iec.html", "source_quote": "Purged/Pressurized | Ex p (Ex px, Ex py, Ex pz) | IEC 60079-2 | Maintain positive pressure with inert gas", "url": "https://referencesource.org/ex-classification-system-crosswalk/ex-p-ex-px-ex-py-ex-pz-protection-concept-purged-pressurized/", "verified_fields": ["basis", "iec_designation", "iec_standard", "north_american_designation"]}
101
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class II", "id": "class-ii-ca-protection-concept-px", "iec_standard": "NFPA 496", "north_american_designation": "(PX)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(PX) CA Class II Division 1 NFPA 496", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-ca-protection-concept-px/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
102
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class II", "id": "class-ii-us-protection-concept-px", "iec_standard": "NFPA 496 (FM 3620)", "north_american_designation": "(PX)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(PX) US Class II Division 1 NFPA 496 (FM 3620)", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-us-protection-concept-px/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
103
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class II", "id": "class-ii-ca-protection-concept-py", "iec_standard": "NFPA 496", "north_american_designation": "(PY)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(PY) CA Class II Division 1 NFPA 496", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-ca-protection-concept-py/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
104
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "hazard_class": "Class II", "id": "class-ii-us-protection-concept-py", "north_american_designation": "(PY)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(PY) US Class II", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-us-protection-concept-py/", "verified_fields": ["country", "hazard_class", "north_american_designation"]}
105
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 2", "hazard_class": "Class II", "id": "class-ii-ca-protection-concept-pz", "iec_standard": "NFPA 496", "north_american_designation": "(PZ)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(PZ) CA Class II Division 2 NFPA 496", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-ca-protection-concept-pz/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
106
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 2", "hazard_class": "Class II", "id": "class-ii-us-protection-concept-pz", "iec_standard": "NFPA 496 (FM 3620)", "north_american_designation": "(PZ)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(PZ) US Class II Division 2 NFPA 496 (FM 3620)", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-ii-us-protection-concept-pz/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
107
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T1 | T1 | 450 | 842", "value": "842"}], "basis": "Ignition temperature of gas / dust >450", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t1-temperature-code-t1", "iec_designation": "T1", "max_surface_temperature_c": "450", "north_american_designation": "T1", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "450 | T1 | >450", "url": "https://referencesource.org/ex-classification-system-crosswalk/t1-temperature-code-t1/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
108
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2 | T2 | 300 | 572", "value": "572"}], "basis": "Ignition temperature of gas / dust >300-450", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t2-temperature-code-t2", "iec_designation": "T2", "max_surface_temperature_c": "300", "north_american_designation": "T2", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "300 | T2 | >300-450", "url": "https://referencesource.org/ex-classification-system-crosswalk/t2-temperature-code-t2/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
109
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T2A | | 280 | 536", "value": "536"}], "basis": "Ignition temperature of gas / dust >280-300", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "temperature-code-t2a", "max_surface_temperature_c": "280", "north_american_designation": "T2A", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "280 | T2A | >280-300", "url": "https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t2a/", "verified_fields": ["max_surface_temperature_c", "north_american_designation"]}
 
118
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T4A | | 120 | 248", "value": "248"}], "basis": "Ignition temperature of gas / dust >120-135", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "temperature-code-t4a", "max_surface_temperature_c": "120", "north_american_designation": "T4A", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "120 | T4A | >120-135", "url": "https://referencesource.org/ex-classification-system-crosswalk/temperature-code-t4a/", "verified_fields": ["max_surface_temperature_c", "north_american_designation"]}
119
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T5 | T5 | 100 | 212", "value": "212"}], "basis": "Ignition temperature of gas / dust >100-135", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t5-temperature-code-t5", "iec_designation": "T5", "max_surface_temperature_c": "100", "north_american_designation": "T5", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "100 | T5 | >100-135", "url": "https://referencesource.org/ex-classification-system-crosswalk/t5-temperature-code-t5/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
120
  {"also_reported": [{"as_of": "2026-08-06", "field": "max_surface_temperature_f", "source": "https://ldpi-inc.com/resources/classification-codes/class-1-locations/", "source_quote": "T6 | T6 | 85 | 185", "value": "185"}], "basis": "Ignition temperature of gas / dust >85-100", "category": "temperature code", "derived_fields": ["category"], "disagreements": [], "id": "t6-temperature-code-t6", "iec_designation": "T6", "max_surface_temperature_c": "85", "north_american_designation": "T6", "source": "https://www.e2s.com/guide-for-hazardous-areas/gas-and-dust-groups", "source_quote": "85 | T6 | >85-100", "url": "https://referencesource.org/ex-classification-system-crosswalk/t6-temperature-code-t6/", "verified_fields": ["iec_designation", "max_surface_temperature_c", "north_american_designation"]}
121
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "hazard_class": "Class I", "id": "class-i-ca-protection-concept-type-x", "north_american_designation": "Type X", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Type X CA Class I", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-type-x/", "verified_fields": ["country", "hazard_class", "north_american_designation"]}
122
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-type-x", "iec_standard": "NFPA 496 (FM 3620)", "north_american_designation": "Type X", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Type X US Class I Division 1 NFPA 496 (FM 3620)", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-type-x/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
123
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-type-y", "iec_standard": "NFPA 496", "north_american_designation": "Type Y", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Type Y CA Class I Division 1 NFPA 496", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-type-y/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
124
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-type-y", "iec_standard": "NFPA 496 (FM 3620)", "north_american_designation": "Type Y", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Type Y US Class I Division 1 NFPA 496 (FM 3620)", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-type-y/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
125
+ {"basis": "Pressurized", "category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 2", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-type-z", "iec_standard": "NFPA 496", "north_american_designation": "Type Z", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Pressurized Type Z CA Class I Division 2 NFPA 496", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-type-z/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
126
+ {"category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 2", "hazard_class": "Class I", "id": "class-i-us-protection-concept-type-z", "iec_standard": "NFPA 496 (FM 3620)", "north_american_designation": "Type Z", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Type Z US Class I Division 2 NFPA 496 (FM 3620)", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-type-z/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
127
+ {"category": "protection concept", "country": "CA", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class I", "id": "class-i-ca-protection-concept-xp", "iec_standard": "C22.2 No. 30", "north_american_designation": "(XP)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "(XP) CA Class I Division 1 C22.2 No. 30", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-ca-protection-concept-xp/", "verified_fields": ["country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}
128
+ {"basis": "Explosion Proof", "category": "protection concept", "country": "US", "derived_fields": ["category"], "division_or_zone": "Division 1", "hazard_class": "Class I", "id": "class-i-us-protection-concept-xp", "iec_standard": "UL 1203", "north_american_designation": "(XP)", "source": "https://www.euroswitch.com/wp-content/uploads/euroswitch-hazardous-area-guide_V6.pdf", "source_quote": "Explosion Proof (XP) US Class I Division 1 UL 1203", "url": "https://referencesource.org/ex-classification-system-crosswalk/class-i-us-protection-concept-xp/", "verified_fields": ["basis", "country", "division_or_zone", "hazard_class", "iec_standard", "north_american_designation"]}