license: cc0-1.0
pretty_name: imaged Fourier ptychography data
task_categories:
- image-to-image
tags:
- fourier-ptychography
- computational-imaging
- microscopy
- raw-bayer
- usaf-1951
- raspberry-pi
size_categories:
- 1K<n<10K
viewer: false
---

# imaged Fourier ptychography data

Raw Fourier ptychographic microscopy (FPM) acquisitions from a low-cost Raspberry Pi
microscope: a Pi Camera Module v2 (Sony IMX219) with its stock lens, illuminated by a
145-LED ring array. Each study is a full single-wavelength acquisition: one raw Bayer
frame per LED, plus dark frames for most studies, with every capture's LED position and
exposure recorded.

The data is laid out to be loaded directly by
[`imaged`](https://github.com/rspcunningham/imaged), a PyTorch FPM reconstruction
library, but the format is plain JSON and NumPy, so any FPM code can use it.

## Studies

| Study | Sample | λ (nm) | Mag / NA | Frame (W×H) | Captures | Notes |
|---|---|---:|---|---|---|---|
| `20240709-005435-usaf-g7` | USAF target, to group 7 | 525 | 1.7 / 0.13 | 3296×2464 | 145 + 7 dark | float32, normalised per frame |
| `20240709-005435-malaria-carolina-9` | Malaria parasite slide | 525 | 1.7 / 0.13 | 3296×2464 | 145 | acquisition date unknown |
| `20250812-164017-usaf-g9` | USAF target, to group 9 | 525 | 2.81 / 0.18 | 2464×3296 | 145 + 7 dark | |
| `20250821-160234-usaf-g9-colour-red` | USAF target, to group 9 | 625 | 2.84 / 0.18 | 2464×3296 | 145 + 7 dark | red LEDs of an RGB run |
| `20250821-160234-usaf-g9-colour-green` | USAF target, to group 9 | 525 | 2.84 / 0.18 | 2464×3296 | 145 + 7 dark | green LEDs of an RGB run |
| `20250821-160234-usaf-g9-colour-blue` | USAF target, to group 9 | 470 | 2.84 / 0.18 | 2464×3296 | 145 + 7 dark | blue LEDs of an RGB run |
| `20260728-122052-usaf-g9` | USAF target, to group 9 | 525 | 2.7 / 0.15 | 1232×1232 | 145 + 7 dark | sensor crop, analog gain 5 |
| `20260902-144551-usaf-g9-analog-gain-1` | USAF target, to group 9 | 525 | 2.7 / 0.15 | 3280×2464 | 145 + 7 dark | analog gain 1 |
| `20261007-174403-usaf-g9-long-exposure` | USAF target, to group 9 | 525 | 2.7 / 0.15 | 3280×2464 | 145 + 7 dark | 4 s exposure throughout |
| `20261007-174946-usaf-g9-30um-defocus` | USAF target, to group 9 | 525 | 2.7 / 0.18 | 3280×2464 | 145 + 7 dark | sample defocused by 30 µm |

Study names are `<acquisition date-time>-<sample>[-<variant>]`. `usaf-g7` and `usaf-g9`
are two different USAF 1951 targets whose finest group is 7 or 9.

## Layout

```text
<study>/
├── info.json        # manifest: optics, Bayer layout, per-capture LED position and exposure
└── captures/*.npy   # one 2-D raw Bayer frame per capture, shape (height, width)
```

The full `info.json` schema is documented in
[`INFO_JSON_SCHEMA.md`](https://github.com/rspcunningham/imaged/blob/main/INFO_JSON_SCHEMA.md).
In short, all lengths are in metres and exposures in seconds. LED positions are relative
to the sample centre, with +z pointing from the sample to the LED array. Dark captures
have no LED position and match the `(channel, exposure)` pairs of the illuminated ones.
Free-form study details (sample, camera, gain, notes) live in `info.json` → `metadata`.

## Usage

Download one study (about 450 MB) and reconstruct it with `imaged`:

```bash
hf download rspcunningham/imaged-data --repo-type dataset \
  --include "20260728-122052-usaf-g9/*" --local-dir datasets
```

```python
from imaged import PtychStudy

study = PtychStudy.load("datasets/20260728-122052-usaf-g9", dark_subtraction="average_all")
study.captures          # [illumination, H, W] demosaiced, dark-subtracted, exposure-normalised
study.illumination_kx   # per-capture illumination spatial frequencies
```

## Known issues

- `20240709-005435-usaf-g7` frames are float32 in [0, 1] and appear to be normalised per
  image at acquisition, so relative brightness between LEDs is not preserved. Its
  `captured_at` timestamps are synthetic.
- `20240709-005435-malaria-carolina-9` has no recorded acquisition date; its timestamps
  were copied from the USAF study of the same era.
- The 2026 studies use the measured numerical aperture of 0.15 instead of the 0.18 the
  acquisition software recorded, except `20261007-174946-usaf-g9-30um-defocus`, which
  still carries 0.18.

## License

Released under [CC0 1.0](https://creativecommons.org/publicdomain/zero/1.0/): no rights
reserved. Attribution is appreciated but not required.