Add data/vlm_run/raw
Browse filesThis view is limited to 50 files because it contains too many changes. See raw diff
- data/vlm_run/raw/pass_a/DEN170022-p17-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170022-p18-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170022-p18-t1__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170022-p18-t1__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN170022-p20-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170022-p22-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170073-p11-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170073-p11-t1__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170073-p14-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170073-p15-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN170073-p15-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN170073-p16-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p11-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p11-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN180005-p12-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p12-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN180005-p15-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p16-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p16-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN180005-p16-t1__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p16-t2__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p16-t2__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN180005-p20-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p21-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN180005-p21-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN180005-p22-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN190040-p11-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN190040-p11-t1__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN190040-p6-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN190040-p6-t1__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN190040-p7-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN190040-p7-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/DEN230023-p5-t0__primary.json +8 -0
- data/vlm_run/raw/pass_a/DEN230023-p5-t0__secondpass.json +8 -0
- data/vlm_run/raw/pass_a/DEN240047-p10-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN240047-p12-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN240047-p14-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN240047-p14-t1__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN240047-p16-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN240047-p4-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN250007-p2-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/DEN250007-p3-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/K141069-p4-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/K141069-p4-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/K141069-p5-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/K141069-p5-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/K141069-p6-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/K141069-p6-t0__secondpass.json +31 -0
- data/vlm_run/raw/pass_a/K141069-p7-t0__primary.json +46 -0
- data/vlm_run/raw/pass_a/K141069-p7-t0__secondpass.json +31 -0
data/vlm_run/raw/pass_a/DEN170022-p17-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 4.463,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "fbc18399d531c5b1e9ef9efea3a75664",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639174,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"Table 1. Reader experience\", \"columns\": [\"Years experience\", \"Breast imaging\", \"Breast MRI\"], \"rows\": [[\"0 \u2013 5\", \"6\", \"8\"], [\"5 \u2013 10\", \"4\", \"7\"], [\"Greater than 10\", \"9\", \"4\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 2059,
|
| 21 |
+
"completion_tokens": 90,
|
| 22 |
+
"total_tokens": 2149,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 1396,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 90,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170022-p18-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 5.574,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "374f594ac5533d93ae7bbf11c17e33de",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639176,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"positive call)\", \"columns\": [\"\", \"1st READ\", \"2nd READ\", \"2nd READ \u2013 1st READ\\nDifference\", \"2nd READ \u2013 1st READ\\n95% CI\"], \"rows\": [[\"Sensitivity\", \"90.4\", \"94.2\", \"3.8\", \"[0.8, 7.4]\"], [\"Specificity\", \"28.6\", \"27.6\", \"-1.0\", \"[-6.5, 4.3]\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 2280,
|
| 21 |
+
"completion_tokens": 138,
|
| 22 |
+
"total_tokens": 2418,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 1617,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 138,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170022-p18-t1__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 5.324,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "e2f499a6064ef03766f0201663a50772",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639175,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"positive call)\", \"columns\": [\"\", \"1st READ\", \"2nd READ\", \"2nd READ \\u2013 1st READ\", \"Difference\", \"95% CI\"], \"rows\": [[\"Sensitivity\", \"79.7\", \"84.8\", \"5.1\", \"[-0.9, 10.9]\"], [\"Specificity\", \"52.2\", \"51.7\", \"-0.5\", \"[-7.3, 6.0]\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 2280,
|
| 21 |
+
"completion_tokens": 137,
|
| 22 |
+
"total_tokens": 2417,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 1617,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 137,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170022-p18-t1__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 14.027,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb108-1b94c27a432310ab0afdf967-chatcmpl-3cc9222",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639177,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"\", \"1st READ\", \"2nd READ\", \"Difference\", \"95% CI\"], \"rows\": [[\"Sensitivity\", \"79.7\", \"84.8\", \"5.1\", \"[-0.9, 10.9]\"], [\"Specificity\", \"52.2\", \"51.7\", \"-0.5\", \"[-7.3, 6.0]\"]], \"header_present\": true}], \"warnings\": [\"The header is two-tiered: '2nd READ \u2013 1st READ' is a merged super-header spanning the 'Difference' and '95% CI' sub-columns; the header was flattened into a single column list.\", \"The first column's header cell is empty (blank) in the image.\", \"Partial text 'positive call)' is visible above the table, cut off at the top of the crop; it appears to be the tail end of a caption or title and was not used as the caption.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "The image shows a table with a header row. The header has a two-level structure: \"1st READ\", \"2nd READ\", \"2nd READ \u2013 1st READ\" (spanning two sub-columns: \"Difference\" and \"95% CI\"). The first column header cell appears empty (the top-left cell is blank/black).\n\nColumns: [\"\", \"1st READ\", \"2nd READ\", \"Difference\", \"95% CI\"] \u2014 but the \"2nd READ \u2013 1st READ\" is a super-header spanning Difference and 95% CI. I should represent columns as printed. Perhaps columns: [\"\", \"1st READ\", \"2nd READ\", \"2nd READ \u2013 1st READ Difference\", \"2nd READ \u2013 1st READ 95% CI\"]? Rule says transcribe exactly what's printed. The header has two rows. I could flatten: first column empty, then \"1st READ\", \"2nd READ\", \"Difference\", \"95% CI\", and note the super-header in warnings. Or include the super-header text in the column names.\n\nI'll use columns: [\"\", \"1st READ\", \"2nd READ\", \"2nd READ \u2013 1st READ Difference\", \"2nd READ \u2013 1st READ 95% CI\"] and add a warning about the two-tier header flattening. Actually, maybe better to keep exact printed text: columns [\"\", \"1st READ\", \"2nd READ\", \"Difference\", \"95% CI\"] with warning that \"Difference\" and \"95% CI\" are sub-columns under a merged super-header \"2nd READ \u2013 1st READ\". That preserves exact transcription.\n\nRows:\nSensitivity: 79.7, 84.8, 5.1, [-0.9, 10.9]\nSpecificity: 52.2, 51.7, -0.5, [-7.3, 6.0]\n\nThere's text above the table: \"positive call)\" \u2014 likely a caption fragment cut off. Caption could be \"positive call)\" but it's partial. I'll set caption to null and note the partial text in warnings, or include it. It's a fragment of a caption/title cut off at top. I'll set caption null and warn.\n\nHeader present: true.\n\nThe dash in \"2nd READ \u2013 1st READ\" is an en dash. Transcribe as \"\u2013\".\n\nWarnings: two-tier header flattened; partial caption text \"positive call)\" visible above table, cut off; first column header cell is empty.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 2816,
|
| 23 |
+
"total_tokens": 3571,
|
| 24 |
+
"completion_tokens": 755,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN170022-p20-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 11.298,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "ee971ea0f56858fcc02a44eb63ff1bd7",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639181,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Identified Risks to Health\", \"Mitigation Measures\"], \"rows\": [[\"Incorrect lesion(s) characterization leading to false positive results may result in incorrect patient management with possible adverse effects such as unnecessary treatment, unnecessary additional medical imaging and/or unnecessary additional diagnostic workup such as biopsy.\", \"Certain design verification and validation activities identified in special control (1)\\nCertain labeling information identified in special control (2)\"], [\"Incorrect lesion(s) characterization leading to false negative results may lead to complications, including incorrect diagnosis and delay in disease management.\", \"Certain design verification and validation activities identified in special control (1)\\nCertain labeling information identified in special control (2)\"], [\"The device could be misused to analyze images from an unintended patient population or on images acquired with incompatible imaging hardware or incompatible image acquisition parameters, leading to inappropriate diagnostic information being displayed to the user.\", \"Certain design verification and validation activities identified in special control (1)\\nCertain labeling information identified in special control (2)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3185,
|
| 21 |
+
"completion_tokens": 229,
|
| 22 |
+
"total_tokens": 3414,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2522,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 229,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170022-p22-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 22.271,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "b15f559fd59976d0432cf76cf5c095b5",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639192,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [],\n \"rows\": [\n [\n \"Summary of Other Factors\",\n \"The study was enriched and individual readers in practice may not experience a significant improvement in diagnosing breast cancer lesions.\"\n ],\n [\n \"Conclusions\\nDo the probable benefits outweigh the probable risks?\",\n \"Yes, the probable benefits outweigh the probable risks, given the combination of required general controls and the special controls established for this device. The Special Controls will sufficiently assist in managing risks associated with incorrect lesion(s) characterization, application of the device results to the wrong patient population, analysis of incompatible images, and/or device failure by insuring proper performance and use of the device.\\n\\nBy providing a systematic automated analysis of a multiple factors in reviewing breast MRI lesions, the device may marginally improve diagnostic performance and consistency in evaluating a multitude of clinical factors. The QuantX analytics calculate the morphological and enhancement characteristics of a breast lesion the QuantX package uses pattern recognition techniques and displays similar lesions from a fixed database of biopsy-proven non-cancer and cancer. A user will be able to view and interpret the lesion characteristics and similar cases during their diagnosis of a patient\u2019s breast lesions.\\n\\nBy demonstrating an ability to assist users in the classification of breast MRI lesions as BIRADS 2, or 3 or 4a, the device may provide improved diagnostic accuracy as assessed by an improvement in AUC. In particular, secondary analyses suggest improved sensitivity based on BI-RADS 3 as the cut-point without decreased specificity for some readers.\\n\\nThe device provides information that may be useful in the characterization of breast abnormalities, but does not replace the physician. The physician determines the diagnosis and the information provided by the device is unlikely to decrease diagnostic performance of the user. Not all users may experience a substantial improvement in diagnostic performance based on the use of the device. However, the device is not likely to lead to a substantial decline in reader performance either.\\n\\nTherefore, given the available information concerning the benefits, risks, and supporting data; the probable benefits outweigh the probable risks, given the combination of required general controls and special controls established for this device.\"\n ]\n ],\n \"header_present\": false\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3156,
|
| 21 |
+
"completion_tokens": 479,
|
| 22 |
+
"total_tokens": 3635,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2493,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 479,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170073-p11-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 6.561,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "7635acd8106fcc092f69bacd24555fcd",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639177,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [\"Standard of Care (N=44)\", \"Time to Notification of Specialist for LVO cases (mins)\"],\n \"rows\": [\n [\"Average [95% CI]\", \"58.72 [46.21, 71.23]\"],\n [\"Median\", \"51.50\"],\n [\"Standard Deviation\", \"41.14\"]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3173,
|
| 21 |
+
"completion_tokens": 128,
|
| 22 |
+
"total_tokens": 3301,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2510,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 128,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170073-p11-t1__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 5.729,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "b6c8dd16dbf8bcf4ba161e2ff59580e5",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639176,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [\"Viz ContaCT (N=44)\", \"Time to Notification of Specialist for LVO cases (mins)\"],\n \"rows\": [\n [\"Average [95% CI]\", \"7.32 [5.51, 9.13]\"],\n [\"Median\", \"5.60\"],\n [\"Standard Deviation\", \"5.95\"]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3173,
|
| 21 |
+
"completion_tokens": 125,
|
| 22 |
+
"total_tokens": 3298,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2510,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 125,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170073-p14-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 20.139,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "d9ee837d4adfa64eb3aa712ca78ffc5e",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639190,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Identified Risks\", \"Mitigation Measures\"], \"rows\": [[\"Failure to prioritize images for review with positive findings may result in incorrect and/or delayed patient management\", \"Certain design verification and validation activities identified in special control (1)\\nCertain labeling information identified in special control (2)\"], [\"Positive notifications may result in deprioritization of review of images from other patients.\", \"Certain design verification and validation activities identified in special control (1)\\nCertain labeling information identified in special control (2)\"], [\"The device could be misused to analyze images from an unintended patient population or on images acquired with incompatible imaging hardware or incompatible image acquisition parameters, leading to inappropriate notifications being displayed to the user.\", \"Certain design verification and validation activities identified in special control (1)\\nCertain labeling information identified in special control (2)\"], [\"Device failure could lead to the absence of results, delay of results or incorrect results, which could likewise lead to inaccurate patient assessment.\", \"Certain design verification and validation activities identified in special control (1)\\nCertain labeling information identified in special control (2)\"], [\"The triage and notification outputs of the device are inappropriately used for primary interpretation or\", \"Certain design verification and validation activities identified in special control (1)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3156,
|
| 21 |
+
"completion_tokens": 286,
|
| 22 |
+
"total_tokens": 3442,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2493,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 286,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170073-p15-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 29.327,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "dc867596af524fbf60034e6f0da80dd6",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639199,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": \"Summary\",\n \"columns\": [\"Summary of the Benefit(s)\", \"Summary of the Risk(s)\"],\n \"rows\": [\n [\n \"In Viz.AI's study the average and median CTA-to-notification times were 58.72 minutes and 51.50 minutes, respectively, for the Standard of Care (two-sided 95% confidence interval for the mean: [46.21, 71.23]. The average and median CTA-to-notification times were 7.32 minutes and 5.60 minutes, respectively, for ContaCT (two-sided 95% confidence interval for the mean: [5.51, 9.13]). This is also lower than the average time to notification of 66 minutes reported in literature for LVO's diagnosed with CT Angiogram. The notification is informed by the software algorithm with a sensitivity and specificity are 87.8% (81.2% - 92.5%) and 89.6% (83.7% - 93.9%), respectively. The clinical benefit is that the device identifies patients who may benefit from rapid intervention by a neurovascular specialist. The clinical benefit is that a patient may be eligible for use of mechanical thrombectomy and/or tPA administration. By using one or both of these techniques, a substantial relative volume of brain may be able to be saved by timely intervention. From an overall US public health perspective, by treating ischemic stroke of large vessels more aggressively, as is now done for acute coronary artery occlusion, the resulting amount of disability from ischemic stroke, which remains a major cause of US disability in both men and women can potentially be significantly decreased.\",\n \"There are no major risks for the device because the device operates in parallel to the current usual standard of care. Minor risks include: \u2022 Failure to prioritize images for review with positive findings may result in incorrect and/or delayed patient management. \u2022 Positive notifications may result in deprioritisation of review of images from other patients. \u2022 The device could be misused to analyse images from an unintended patient population or on images acquired with incompatible imaging hardware or incompatible image acquisition parameters, leading to inappropriate notifications being displayed to the user. \u2022 Device failure could lead to the absence of results, delay of results or incorrect results, which could likewise lead to inaccurate patient assessment. \u2022 The triage and notification outputs of the device are inappropriately used for primary interpretation or as an adjunct for diagnosis outside the intended use of the device.\"\n ]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3165,
|
| 21 |
+
"completion_tokens": 569,
|
| 22 |
+
"total_tokens": 3734,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2502,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 569,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN170073-p15-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 25.98,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb11f-0286e0a51ebd99d747acef53-chatcmpl-1c59525",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639201,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Summary\"], \"rows\": [[\"Summary of the Benefit(s)\", \"In Viz.AI's study the average and median CTA-to-notification times were 58.72 minutes and 51.50 minutes, respectively, for the Standard of Care (two-sided 95% confidence interval for the mean: [46.21, 71.23]. The average and median CTA-to-notification times were 7.32 minutes and 5.60 minutes, respectively, for ContaCT (two-sided 95% confidence interval for the mean: [5.51, 9.13]). This is also lower than the average time to notification of 66 minutes reported in literature for LVO's diagnosed with CT Angiogram. The notification is informed by the software algorithm with a sensitivity and specificity are 87.8% (81.2% - 92.5%) and 89.6% (83.7% - 93.9%), respectively.\\nThe clinical benefit is that the device identifies patients who may benefit from rapid intervention by a neurovascular specialist. The clinical benefit is that a patient may be eligible for use of mechanical thrombectomy and/or tPA administration. By using one or both of these techniques, a substantial relative volume of brain may be able to be saved by timely intervention.\\nFrom an overall US public health perspective, by treating ischemic stroke of large vessels more aggressively, as is now done for acute coronary artery occlusion, the resulting amount of disability from ischemic stroke, which remains a major cause of US disability in both men and women can potentially be significantly decreased.\"], [\"Summary of the Risk(s)\", \"There are no major risks for the device because the device operates in parallel to the current usual standard of care.\\n\\nMinor risks include:\\n\u2022 Failure to prioritize images for review with positive findings may result in incorrect and/or delayed patient management.\\n\u2022 Positive notifications may result in deprioritisation of review of images from other patients.\\n\u2022 The device could be misused to analyse images from an unintended patient population or on images acquired with incompatible imaging hardware or incompatible image acquisition parameters, leading to inappropriate notifications being displayed to the user.\\n\u2022 Device failure could lead to the absence of results, delay of results or incorrect results, which could likewise lead to inaccurate patient assessment.\\n\u2022 The triage and notification outputs of the device are inappropriately used for primary interpretation or as an adjunct for diagnosis outside the intended use of the device.\"]], \"header_present\": true}], \"warnings\": [\"The printed header is a single merged cell 'Summary' spanning the full table width (both columns), while each body row contains 2 cells (a row-label cell and a text cell); rows therefore have more cells than the single printed header, transcribed as printed per rules.\", \"In the Benefit(s) text, the phrase '(two-sided 95% confidence interval for the mean: [46.21, 71.23].' appears in the source without a visible closing parenthesis before the period; transcribed exactly as printed.\", \"Numeric values embedded in the narrative text (e.g., 58.72, 51.50, [46.21, 71.23], 7.32, 5.60, [5.51, 9.13], 66, 87.8% (81.2% - 92.5%), 89.6% (83.7% - 93.9%)) are part of prose paragraphs within a single table cell, not separate tabular columns.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "The image shows a table with a header row \"Summary\" spanning, and two rows: \"Summary of the Benefit(s)\" and \"Summary of the Risk(s)\". The left column contains the row labels, the right column contains long text.\n\nStructure: It appears to be a 2-column table. The header row has \"Summary\" centered across both columns (merged). Actually the header \"Summary\" appears to span the whole width. So header_present: true, columns: [\"Summary\"]? But the body has two columns. Hmm.\n\nThe header row is a single merged cell \"Summary\" spanning both columns. The body rows have two cells each: label and text.\n\nHow to represent? Options: columns: [\"Summary\"] with rows having 2 cells each \u2014 mismatch. Or treat header as two columns where the second is empty? The printed header is just \"Summary\" spanning. Rule 8 says don't force alignment; transcribe as printed and flag mismatch.\n\nI think best: columns: [\"Summary\"], header_present: true, rows each with 2 cells, and a warning that the header is a single merged cell spanning two columns while body rows have 2 cells.\n\nAlternatively, columns could be [\"Summary\", \"\"] \u2014 but that fabricates. Better to keep [\"Summary\"] and warn.\n\nCaption: null (no caption visible).\n\nTranscribe the text exactly. Let me transcribe the benefit text:\n\n\"In Viz.AI's study the average and median CTA-to-notification times were 58.72 minutes and 51.50 minutes, respectively, for the Standard of Care (two-sided 95% confidence interval for the mean: [46.21, 71.23]. The average and median CTA-to-notification times were 7.32 minutes and 5.60 minutes, respectively, for ContaCT (two-sided 95% confidence interval for the mean: [5.51, 9.13]). This is also lower than the average time to notification of 66 minutes reported in literature for LVO's diagnosed with CT Angiogram. The notification is informed by the software algorithm with a sensitivity and specificity are 87.8% (81.2% - 92.5%) and 89.6% (83.7% - 93.9%), respectively.\n\nThe clinical benefit is that the device identifies patients who may benefit from rapid intervention by a neurovascular specialist. The clinical benefit is that a patient may be eligible for use of mechanical thrombectomy and/or tPA administration. By using one or both of these techniques, a substantial relative volume of brain may be able to be saved by timely intervention.\n\nFrom an overall US public health perspective, by treating ischemic stroke of large vessels more aggressively, as is now done for acute coronary artery occlusion, the resulting amount of disability from ischemic stroke, which remains a major cause of US disability in both men and women can potentially be significantly decreased.\"\n\nNote: the text has \"(two-sided 95% confidence interval for the mean: [46.21, 71.23].\" \u2014 appears missing closing paren in the original; transcribe as printed. Actually looking: \"for the Standard of Care (two-sided 95% confidence interval for the mean: [46.21, 71.23]. The average...\" \u2014 yes it seems the closing parenthesis is missing before the period. I'll transcribe as printed. Hmm, it could be \"[46.21, 71.23].\" \u2014 I'll keep as printed.\n\nRisk text:\n\n\"There are no major risks for the device because the device operates in parallel to the current usual standard of care.\n\nMinor risks include:\n\n\u2022 Failure to prioritize images for review with positive findings may result in incorrect and/or delayed patient management.\n\u2022 Positive notifications may result in deprioritisation of review of images from other patients.\n\u2022 The device could be misused to analyse images from an unintended patient population or on images acquired with incompatible imaging hardware or incompatible image acquisition parameters, leading to inappropriate notifications being displayed to the user.\n\u2022 Device failure could lead to the absence of results, delay of results or incorrect results, which could likewise lead to inaccurate patient assessment.\n\u2022 The triage and notification outputs of the device are inappropriately used for primary interpretation or as an adjunct for diagnosis outside the intended use of the device.\"\n\nShould I keep bullet characters? I'll include them as \"\u2022 \" within the text, or use newlines. I'll keep the text with newlines and bullet markers.\n\nWarnings: header is a merged single cell \"Summary\" spanning two columns; body rows have 2 cells each, so row cell count (2) differs from header column count (1). Also note possible missing closing parenthesis in the benefit text transcribed as printed.\n\nunreadable: false.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 16246,
|
| 23 |
+
"total_tokens": 17993,
|
| 24 |
+
"completion_tokens": 1747,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN170073-p16-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 18.692,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "0960dde220e0df8fdf950ab09194f663",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639189,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [],\n \"rows\": [\n [\n \"Summary of Other Factors\",\n \"The device only notifies the neurovascular specialist. Beyond that it is up the regional healthcare delivery system to get the patient the neurovascular specialist in the neurovascular interventional suite/operating room. If adequately treated in time the patient will have no residual neurological deficit. In some cases there may be a small residual neurological deficit. If the disease is untreated, there may be loss of speech, recognition of words, movement of the arms and/or legs, normal bowel and bladder control, or other neurologic functions resulting potentially in long term disability.\"\n ],\n [\n \"Conclusions\\nDo the probable benefits outweigh the probable risks?\",\n \"Yes. The benefit of ContaCT, namely, early identification and notification of a specialist significantly outweighs the minimal risk of a small amount of the specialists time needed to review and disregard a false positive. In the case of a false negative, the standard of care workflow prevails, so there is no risk compared to standard of care for the patient. In general, there is no direct risk to the patient as this is a notification only, software only device. There are no significant risks which have not been mitigated via clinical testing and labelling. Therefore, given the available information concerning the benefits, risks, and supporting data, the probable benefits for the device outweighs the probable risks, given the combination of general controls and special controls established for this device.\"\n ]\n ],\n \"header_present\": false\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3144,
|
| 21 |
+
"completion_tokens": 345,
|
| 22 |
+
"total_tokens": 3489,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2481,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 345,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p11-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 10.121,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "fef4b65b275c1d249c16109626a272ce",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639180,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Performance Metric\", \"Estimate\", \"90%\", \"95%\"], \"rows\": [[\"Sensitivity\", \"0.921\", \"(0.892, 0.942)\", \"(0.886, 0.946)\"], [\"Specificity\", \"0.902\", \"(0.882, 0.919)\", \"(0.877, 0.922)\"], [\"PPV\", \"0.813\", \"(0.777, 0.844)\", \"(0.769, 0.850)\"], [\"NPV\", \"0.961\", \"(0.946, 0.972)\", \"(0.943, 0.973)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3193,
|
| 21 |
+
"completion_tokens": 209,
|
| 22 |
+
"total_tokens": 3402,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2530,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 209,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p11-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 9.993,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb10d-3ca34af32f039aa32889a8bb-chatcmpl-e873831",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639183,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Performance Metric\", \"Estimate\", \"90%\", \"95%\"], \"rows\": [[\"Sensitivity\", \"0.921\", \"(0.892, 0.942)\", \"(0.886, 0.946)\"], [\"Specificity\", \"0.902\", \"(0.882, 0.919)\", \"(0.877, 0.922)\"], [\"PPV\", \"0.813\", \"(0.777, 0.844)\", \"(0.769, 0.850)\"], [\"NPV\", \"0.961\", \"(0.946, 0.972)\", \"(0.943, 0.973)\"]], \"header_present\": true}], \"warnings\": [\"The table has a two-level header: a super-header 'Wilson's Confidence Intervals' spans the '90%' and '95%' columns; the columns list uses the lower-level header row only.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "The image shows a table with a two-level header. Top row: empty cell spanning first two columns, then \"Wilson's Confidence Intervals\" spanning two columns. Second header row: \"Performance Metric\", \"Estimate\", \"90%\", \"95%\".\n\nRows:\n- Sensitivity | 0.921 | (0.892, 0.942) | (0.886, 0.946)\n- Specificity | 0.902 | (0.882, 0.919) | (0.877, 0.922)\n- PPV | 0.813 | (0.777, 0.844) | (0.769, 0.850)\n- NPV | 0.961 | (0.946, 0.972) | (0.943, 0.973)\n\nHeader present: true. Columns: [\"Performance Metric\", \"Estimate\", \"90%\", \"95%\"]. I should note the super-header \"Wilson's Confidence Intervals\" spans the 90% and 95% columns \u2014 could add a warning or include in caption. Caption is null (no caption visible). I could note the merged header in warnings.\n\nNo goals/targets visible. No chart. All readable.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 5454,
|
| 23 |
+
"total_tokens": 5931,
|
| 24 |
+
"completion_tokens": 477,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p12-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 35.007,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "70b2a7d2440fd8e217823e902feac0e8",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639205,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [\"Subgroup\", \"View\", \"Characteristic\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"],\n \"rows\": [\n [\"PA\", \"Post-Surgical: No\", \"0.904 (0.832, 0.947)\", \"0.934 (0.902, 0.955)\", \"0.805 (0.724, 0.867)\", \"0.970 (0.945, 0.984)\"],\n [\"PA\", \"Post-Surgical: Yes\", \"0.920 (0.864, 0.954)\", \"0.779 (0.698, 0.844)\", \"0.829 (0.762, 0.880)\", \"0.893 (0.820, 0.939)\"],\n [\"PA\", \"Age < 80\", \"0.908 (0.863, 0.940)\", \"0.897 (0.866, 0.922)\", \"0.813 (0.759, 0.857)\", \"0.952 (0.928, 0.969)\"],\n [\"PA\", \"Age \u2265 80\", \"0.950 (0.804, 0.989)\", \"0.800 (0.591, 0.917)\", \"0.864 (0.703, 0.944)\", \"0.923 (0.718, 0.983)\"],\n [\"LAT\", \"Post-Surgical: No\", \"0.940 (0.874, 0.973)\", \"0.951 (0.925, 0.968)\", \"0.818 (0.736, 0.879)\", \"0.985 (0.968, 0.993)\"],\n [\"LAT\", \"Post-Surgical: Yes\", \"0.921 (0.855, 0.959)\", \"0.750 (0.658, 0.824)\", \"0.795 (0.716, 0.857)\", \"0.900 (0.818, 0.947)\"],\n [\"LAT\", \"Age < 80\", \"0.925 (0.878, 0.955)\", \"0.912 (0.883, 0.934)\", \"0.804 (0.746, 0.851)\", \"0.969 (0.949, 0.981)\"],\n [\"LAT\", \"Age \u2265 80\", \"1.000 (0.787, 1.000)\", \"0.875 (0.684, 0.958)\", \"0.833 (0.601, 0.943)\", \"1.000 (0.838, 1.000)\"]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3173,
|
| 21 |
+
"completion_tokens": 812,
|
| 22 |
+
"total_tokens": 3985,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2510,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 812,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p12-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 63.295,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb12c-26e5807f4579c0a107d33c1a-chatcmpl-2b96025",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639213,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"View\", \"Characteristic\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"], \"rows\": [[\"PA\", \"Post-Surgical: No\", \"0.904 (0.832, 0.947)\", \"0.934 (0.902, 0.955)\", \"0.805 (0.724, 0.867)\", \"0.970 (0.945, 0.984)\"], [\"PA\", \"Post-Surgical: Yes\", \"0.920 (0.864, 0.954)\", \"0.779 (0.698, 0.844)\", \"0.829 (0.762, 0.880)\", \"0.893 (0.820, 0.939)\"], [\"PA\", \"Age < 80\", \"0.908 (0.863, 0.940)\", \"0.897 (0.866, 0.922)\", \"0.813 (0.759, 0.857)\", \"0.952 (0.928, 0.969)\"], [\"PA\", \"Age \u2265 80\", \"0.950 (0.804, 0.989)\", \"0.800 (0.591, 0.917)\", \"0.864 (0.703, 0.944)\", \"0.923 (0.718, 0.983)\"], [\"LAT\", \"Post-Surgical: No\", \"0.940 (0.874, 0.973)\", \"0.951 (0.925, 0.968)\", \"0.818 (0.736, 0.879)\", \"0.985 (0.968, 0.993)\"], [\"LAT\", \"Post-Surgical: Yes\", \"0.921 (0.855, 0.959)\", \"0.750 (0.658, 0.824)\", \"0.795 (0.716, 0.857)\", \"0.900 (0.818, 0.947)\"], [\"LAT\", \"Age < 80\", \"0.925 (0.878, 0.955)\", \"0.912 (0.883, 0.934)\", \"0.804 (0.746, 0.851)\", \"0.969 (0.949, 0.981)\"], [\"LAT\", \"Age \u2265 80\", \"1.000 (0.787, 1.000)\", \"0.875 (0.684, 0.958)\", \"0.833 (0.601, 0.943)\", \"1.000 (0.838, 1.000)\"]], \"header_present\": true}], \"warnings\": [\"Table caption is cut off at the top of the crop; only a partial '1' (likely 'Table 1 ...') is visible, so caption is set to null.\", \"Two-tier header: a super-header row prints 'Subgroup' (spanning the View and Characteristic columns) and 'Performance Metric (90% Wilson's CI)' (spanning Sensitivity, Specificity, PPV, NPV). The second header row was used as the column names.\", \"The 'View' values 'PA' and 'LAT' are vertically merged cells each spanning 4 rows; the label was propagated down into every covered row per instructions.\", \"Glyph artifact normalized: the Characteristic values printed as 'Age : 80' (rows 4 and 8) use a broken glyph for the greater-than-or-equal sign; transcribed semantically as 'Age \u2265 80'.\", \"Each metric cell contains an estimate with its 90% Wilson's CI on a second line; these were kept intact as single string cells, e.g. '0.904 (0.832, 0.947)'.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "Let me analyze the image carefully.\n\nThe table has a two-row header:\n- Row 1: \"Subgroup\" (spanning two columns) | \"Performance Metric (90% Wilson's CI)\" (spanning four columns)\n- Row 2: \"View\" | \"Characteristic\" | \"Sensitivity\" | \"Specificity\" | \"PPV\" | \"NPV\"\n\nSo the columns are: View, Characteristic, Sensitivity, Specificity, PPV, NPV\n\nRows:\n1. PA | Post-Surgical: No | 0.904 (0.832, 0.947) | 0.934 (0.902, 0.955) | 0.805 (0.724, 0.867) | 0.970 (0.945, 0.984)\n2. PA (merged) | Post-Surgical: Yes | 0.920 (0.864, 0.954) | 0.779 (0.698, 0.844) | 0.829 (0.762, 0.880) | 0.893 (0.820, 0.939)\n3. PA (merged) | Age < 80 | 0.908 (0.863, 0.940) | 0.897 (0.866, 0.922) | 0.813 (0.759, 0.857) | 0.952 (0.928, 0.969)\n4. PA (merged) | Age \u2265 80 (shown as \"Age : 80\" with a glyph artifact - likely \"Age \u2265 80\") | 0.950 (0.804, 0.989) | 0.800 (0.591, 0.917) | 0.864 (0.703, 0.944) | 0.923 (0.718, 0.983)\n5. LAT | Post-Surgical: No | 0.940 (0.874, 0.973) | 0.951 (0.925, 0.968) | 0.818 (0.736, 0.879) | 0.985 (0.968, 0.993)\n6. LAT (merged) | Post-Surgical: Yes | 0.921 (0.855, 0.959) | 0.750 (0.658, 0.824) | 0.795 (0.716, 0.857) | 0.900 (0.818, 0.947)\n7. LAT (merged) | Age < 80 | 0.925 (0.878, 0.955) | 0.912 (0.883, 0.934) | 0.804 (0.746, 0.851) | 0.969 (0.949, 0.981)\n8. LAT (merged) | Age \u2265 80 (shown as \"Age : 80\") | 1.000 (0.787, 1.000) | 0.875 (0.684, 0.958) | 0.833 (0.601, 0.943) | 1.000 (0.838, 1.000)\n\nThe \"Age : 80\" appears to be a glyph artifact of \"Age \u2265 80\" - the \"\u2265\" symbol rendered as \":\" or similar. Per rule 6, I should transcribe the correct semantic value \"Age \u2265 80\" and flag the normalization in warnings.\n\nThe \"PA\" label spans rows 1-4, and \"LAT\" spans rows 5-8. Per rule 2, propagate down.\n\nThe header: there's a two-tier header. The top tier has \"Subgroup\" spanning View+Characteristic and \"Performance Metric (90% Wilson's CI)\" spanning the four metric columns. The second tier has the actual column names. I'll use the second tier as columns since those are the actual column headers. I could note the super-header in warnings or caption.\n\nCaption: There's a partial \"1\" at the top - likely \"Table 1\" cut off. The caption is cut off, so I'll set caption to null or note it. Actually there's a \"1\" visible at top center, suggesting the caption \"Table 1...\" is cut off. I'll set caption to null and add a warning.\n\nHeader present: true.\n\nColumns: [\"View\", \"Characteristic\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"]\n\nWarnings:\n- \"Age : 80\" normalized to \"Age \u2265 80\" (glyph artifact)\n- Caption cut off at top (only \"1\" visible, likely \"Table 1\")\n- Super-header row \"Subgroup\" / \"Performance Metric (90% Wilson's CI)\" spans column groups; used second header row as columns.\n- Merged cells PA/LAT propagated down.\n\nLet me double check numbers from the image:\n\nRow 1 (PA, Post-Surgical: No): Sensitivity 0.904 (0.832, 0.947); Specificity 0.934 (0.902, 0.955); PPV 0.805 (0.724, 0.867); NPV 0.970 (0.945, 0.984). \u2713\n\nRow 2 (PA, Post-Surgical: Yes): 0.920 (0.864, 0.954); 0.779 (0.698, 0.844); 0.829 (0.762, 0.880); 0.893 (0.820, 0.939). \u2713\n\nRow 3 (PA, Age < 80): 0.908 (0.863, 0.940); 0.897 (0.866, 0.922); 0.813 (0.759, 0.857); 0.952 (0.928, 0.969). \u2713\n\nRow 4 (PA, Age \u2265 80): 0.950 (0.804, 0.989); 0.800 (0.591, 0.917); 0.864 (0.703, 0.944); 0.923 (0.718, 0.983). \u2713\n\nRow 5 (LAT, Post-Surgical: No): 0.940 (0.874, 0.973); 0.951 (0.925, 0.968); 0.818 (0.736, 0.879); 0.985 (0.968, 0.993). \u2713\n\nRow 6 (LAT, Post-Surgical: Yes): 0.921 (0.855, 0.959); 0.750 (0.658, 0.824); 0.795 (0.716, 0.857); 0.900 (0.818, 0.947). \u2713\n\nRow 7 (LAT, Age < 80): 0.925 (0.878, 0.955); 0.912 (0.883, 0.934); 0.804 (0.746, 0.851); 0.969 (0.949, 0.981). \u2713\n\nRow 8 (LAT, Age \u2265 80): 1.000 (0.787, 1.000); 0.875 (0.684, 0.958); 0.833 (0.601, 0.943); 1.000 (0.838, 1.000). \u2713\n\nFormat the estimate cells as single strings: \"0.904 (0.832, 0.947)\".\n\nJSON output.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 13646,
|
| 23 |
+
"total_tokens": 16113,
|
| 24 |
+
"completion_tokens": 2467,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p15-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 12.507,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "bd4f9322b6eadd0f7150af3f39870492",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639183,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [\"Model\", \"Modality\", \"AUC\", \"Std. Error\", \"OD Aided \u2013 OD Unaided\", \"Std. Error\", \"p-value\", \"95% Lower CL\", \"95% Upper CL\"],\n \"rows\": [\n [\"ROC AUC Full Model\", \"OD - Aided\", \"0.889\", \"0.029\", \"0.049\", \"0.013\", \"0.0056\", \"0.019\", \"0.080\"],\n [\"ROC AUC Full Model\", \"OD - Unaided\", \"0.840\", \"0.029\", \"-\", \"-\", \"-\", \"-\", \"-\"]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3113,
|
| 21 |
+
"completion_tokens": 198,
|
| 22 |
+
"total_tokens": 3311,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2450,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 198,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p16-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 12.615,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "958e4e755553a2f09a3488f107e382de",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639183,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Modality\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"], \"rows\": [[\"OD-Aided\", \"0.803\\n(0.785, 0.819)\", \"0.914\\n(0.903, 0.924)\", \"0.883\\n(0.868, 0.896)\", \"0.853\\n(0.839, 0.865)\"], [\"OD-Unaided\", \"0.747\\n(0.728, 0.765)\", \"0.889\\n(0.876, 0.900)\", \"0.844\\n(0.826, 0.859)\", \"0.814\\n(0.800, 0.828)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3176,
|
| 21 |
+
"completion_tokens": 233,
|
| 22 |
+
"total_tokens": 3409,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2513,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 233,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p16-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 11.252,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb10f-7e3a8b364f9130dc223efeac-chatcmpl-3e423cc",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639185,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Modality\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"], \"rows\": [[\"OD-Aided\", \"0.803 (0.785, 0.819)\", \"0.914 (0.903, 0.924)\", \"0.883 (0.868, 0.896)\", \"0.853 (0.839, 0.865)\"], [\"OD-Unaided\", \"0.747 (0.728, 0.765)\", \"0.889 (0.876, 0.900)\", \"0.844 (0.826, 0.859)\", \"0.814 (0.800, 0.828)\"]], \"header_present\": true}], \"warnings\": [\"Table has a two-tier header: a super-header 'Estimate (95% Wilson's CI)' spans the four metric columns (Sensitivity, Specificity, PPV, NPV) above the printed column names; the column names row was used as 'columns'.\", \"In each data cell the point estimate and the 95% CI were printed on two separate lines; they were combined into a single 'estimate (lo, hi)' string per cell per instructions.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "The image shows a table with a two-row header. The top header row has an empty cell over \"Modality\" and a merged cell \"Estimate (95% Wilson's CI)\" spanning the four metric columns. The second header row has: Modality, Sensitivity, Specificity, PPV, NPV.\n\nRows:\n- OD-Aided: 0.803 (0.785, 0.819), 0.914 (0.903, 0.924), 0.883 (0.868, 0.896), 0.853 (0.839, 0.865)\n- OD-Unaided: 0.747 (0.728, 0.765), 0.889 (0.876, 0.900), 0.844 (0.826, 0.859), 0.814 (0.800, 0.828)\n\nEach cell contains estimate on one line and CI on the next line. Per rule 3, keep \"estimate (lo, hi)\" as one string cell. So each cell: \"0.803 (0.785, 0.819)\" etc.\n\nColumns: [\"Modality\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"]. Header present: true. The top merged header \"Estimate (95% Wilson's CI)\" is a super-header; I could note it in warnings or include it. The columns should be the actual column headers. I'll note the super-header in warnings.\n\nCaption: null (no caption visible).\n\nWarnings: mention the super-header row \"Estimate (95% Wilson's CI)\" spanning the four metric columns; mention that estimate and CI were printed on separate lines within each cell and combined into a single string.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 4621,
|
| 23 |
+
"total_tokens": 5265,
|
| 24 |
+
"completion_tokens": 644,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p16-t1__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 10.263,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "62605ed43d5f1dedc024c7feb060f256",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639180,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Modality\", \"TP\", \"TN\", \"FP\", \"FN\"], \"rows\": [[\"OD-Aided\", \"1715\", \"2436\", \"228\", \"421\"], [\"OD-Unaided\", \"1596\", \"2368\", \"296\", \"540\"], [\"Total\", \"3311\", \"4804\", \"524\", \"961\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 2620,
|
| 21 |
+
"completion_tokens": 128,
|
| 22 |
+
"total_tokens": 2748,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 1957,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 128,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p16-t2__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 19.725,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "519b5cc5d064c5c1c220b1c32de41289",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639190,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"views are available in a case:\", \"columns\": [\"Modality\", \"Number (Type) of Views\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"], \"rows\": [[\"OD - Aided\", \"2 (PA + LAT)\", \"0.810 (0.782, 0.835)\", \"0.915 (0.897, 0.930)\", \"0.871 (0.845, 0.893)\", \"0.872 (0.852, 0.889)\"], [\"OD - Unaided\", \"2 (PA + LAT)\", \"0.732 (0.700, 0.761)\", \"0.898 (0.879, 0.914)\", \"0.835 (0.806, 0.860)\", \"0.825 (0.803, 0.845)\"], [\"OD - Aided\", \"3 (PA + LAT + OBL)\", \"0.798 (0.776, 0.819)\", \"0.914 (0.899, 0.927)\", \"0.890 (0.871, 0.907)\", \"0.839 (0.820, 0.856)\"], [\"OD - Unaided\", \"3 (PA + LAT + OBL)\", \"0.757 (0.733, 0.779)\", \"0.882 (0.865, 0.898)\", \"0.849 (0.827, 0.868)\", \"0.806 (0.786, 0.824)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3207,
|
| 21 |
+
"completion_tokens": 450,
|
| 22 |
+
"total_tokens": 3657,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2544,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 450,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p16-t2__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 43.285,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb117-73a748f44250a2de2fa1b133-chatcmpl-ed74540",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639193,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"views are available in a case:\", \"columns\": [\"Modality\", \"Number (Type) of Views\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"], \"rows\": [[\"OD - Aided\", \"2 (PA + LAT)\", \"0.810 (0.782, 0.835)\", \"0.915 (0.897, 0.930)\", \"0.871 (0.845, 0.893)\", \"0.872 (0.852, 0.889)\"], [\"OD - Unaided\", \"2 (PA + LAT)\", \"0.732 (0.700, 0.761)\", \"0.898 (0.879, 0.914)\", \"0.835 (0.806, 0.860)\", \"0.825 (0.803, 0.845)\"], [\"OD - Aided\", \"3 (PA + LAT + OBL)\", \"0.798 (0.776, 0.819)\", \"0.914 (0.899, 0.927)\", \"0.890 (0.871, 0.907)\", \"0.839 (0.820, 0.856)\"], [\"OD - Unaided\", \"3 (PA + LAT + OBL)\", \"0.757 (0.733, 0.779)\", \"0.882 (0.865, 0.898)\", \"0.849 (0.827, 0.868)\", \"0.806 (0.786, 0.824)\"]], \"header_present\": true}], \"warnings\": [\"The table has a two-tier header: a super-header 'Estimate (95% Wilson's CI)' spans the Sensitivity, Specificity, PPV, and NPV columns; the columns array contains the printed leaf-level headers only.\", \"The caption text 'views are available in a case:' is partially cut off at the top of the crop and appears to be the end of a longer sentence.\", \"Multi-line cell contents (e.g., 'Number (Type) of Views', 'OD - Unaided', '3 (PA + LAT + OBL)', and estimate values wrapped across two lines) were joined into single strings.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "Let me analyze the image carefully.\n\nThe image shows a table with a header structure:\n- Top row: empty cell spanning first two columns, then \"Estimate (95% Wilson's CI)\" spanning the last four columns\n- Second header row: \"Modality\", \"Number (Type) of Views\", \"Sensitivity\", \"Specificity\", \"PPV\", \"NPV\"\n\nRows:\n1. OD - Aided | 2 (PA + LAT) | 0.810 (0.782, 0.835) | 0.915 (0.897, 0.930) | 0.871 (0.845, 0.893) | 0.872 (0.852, 0.889)\n2. OD - Unaided | 2 (PA + LAT) | 0.732 (0.700, 0.761) | 0.898 (0.879, 0.914) | 0.835 (0.806, 0.860) | 0.825 (0.803, 0.845)\n3. OD - Aided | 3 (PA + LAT + OBL) | 0.798 (0.776, 0.819) | 0.914 (0.899, 0.927) | 0.890 (0.871, 0.907) | 0.839 (0.820, 0.856)\n4. OD - Unaided | 3 (PA + LAT + OBL) | 0.757 (0.733, 0.779) | 0.882 (0.865, 0.898) | 0.849 (0.827, 0.868) | 0.806 (0.786, 0.824)\n\nThere's text above the table: \"views are available in a case:\" which appears to be a caption fragment (cut off).\n\nThe header has two levels. The columns should be the leaf-level headers: Modality, Number (Type) of Views, Sensitivity, Specificity, PPV, NPV. The \"Estimate (95% Wilson's CI)\" is a super-header spanning the four metric columns.\n\nFor the columns array, I'll use the printed leaf headers. I could note the super-header in warnings.\n\nCaption: The visible text above is \"views are available in a case:\" \u2014 it's a fragment. I could set caption to that string or null. It's partially visible, so I'll include it as the caption text visible, perhaps noting it's truncated. Actually the rule says transcribe exactly what's printed. The caption fragment is \"views are available in a case:\". I'll include it and note truncation in warnings.\n\nHeader present: true.\n\nEach estimate cell should be kept intact as one string, e.g., \"0.810 (0.782, 0.835)\".\n\nWarnings: mention the two-tier header with \"Estimate (95% Wilson's CI)\" spanning Sensitivity/Specificity/PPV/NPV; caption appears truncated at top of crop.\n\nNo goals/targets visible. No chart. No unreadable cells.\n\nLet me construct the JSON.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 6794,
|
| 23 |
+
"total_tokens": 7945,
|
| 24 |
+
"completion_tokens": 1151,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p20-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 18.167,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "e2ae6dd79e00b0f7d34b92285d882e4d",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639188,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Identified Risks\", \"Identified Mitigation Measures\"], \"rows\": [[\"False positive results\", \"General controls and special controls (1) and (2).\"], [\"False negative results\", \"General controls and special controls (1) and (2).\"], [\"Device misuse (analyzing images from unintended patient population or of an unintended anatomical site; or images acquired with an unintended modality, incompatible imaging hardware, or incompatible image acquisition parameters) resulting in lower device performance (inappropriate detection/diagnosis information being displayed to the end user)\", \"General controls and special controls (1) and (2).\"], [\"Device failure could lead to absence of results, delay of results, or incorrect results, which can lead to delayed or inaccurate patient diagnosis\", \"General controls and special controls (1) and (2).\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3185,
|
| 21 |
+
"completion_tokens": 197,
|
| 22 |
+
"total_tokens": 3382,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2522,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 197,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p21-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 34.607,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "07022b3cd5cbd284fc5ba21667abfe0b",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639205,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": \"Summary\",\n \"columns\": [\"Summary of the Benefit(s)\", \"Summary of the Risk(s)\"],\n \"rows\": [\n [\n \"The clinical MRMC study demonstrated a statistically significant improvement in reader performance in detecting distal radius fracture in adult patients (as measured by the primary endpoint of the ROC Area Under the Curve) when aided with OsteoDetect as compared to performance at the same task without OsteoDetect, according to clinical standard of care.\\n\\nAUCaided - AUCunaided = 0.889 - 0.840 = 0.049 (two sided 95% confidence level [0.019,0.080])\\n\\nOsteoDetect-aided read performance also showed statistically significant improvement as measured by sensitivity, specificity, PPV, and NPV as compared with the unaided read performance. Specifically, Imagen's study demonstrated a device-aided sensitivity of 80.3% (two sided 95% confidence interval for the mean: [78.5%,81.9%]) and device-aided specificity of 91.4% (two sided 95% confidence interval for the mean: [90.3%,92.4%]). By comparison, the study demonstrated non-aided sensitivity and specificity of 74.7% [72.8%,76.5%] and 88.9% [87.6%,90.0%], respectively.\\n\\nEarlier detection of a distal radial fracture will allow earlier intervention, potentially allowing closed reduction and casting instead of open reduction, minimizing the risk of delayed pain and post-traumatic arthritis.\",\n \"There are minimal potential risks associated with use of the device, including:\\n\\n\u2022 The device could provide false positive results, which could contribute to the end user using this information to make a false positive diagnosis. Such a false positive diagnosis can result in unnecessary patient treatment or followup.\\n\\n\u2022 The device could provide false negative results, which could contribute to the end user using this information to make a false negative diagnosis. A false negative diagnosis could lead to delays in diagnosis and treatment of the fracture and increase the likelihood of negative outcomes such as incomplete fracture healing.\\n\\n\u2022 The device could be misused to analyze images from an unintended patient population or on images acquired with\"\n ]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3173,
|
| 21 |
+
"completion_tokens": 544,
|
| 22 |
+
"total_tokens": 3717,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2510,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 544,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p21-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 80.683,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb125-3af5ef7d58b9e95a06146e12-chatcmpl-666e467",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639207,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Summary\"], \"rows\": [[\"Summary of the Benefit(s)\", \"The clinical MRMC study demonstrated a statistically significant improvement in reader performance in detecting distal radius fracture in adult patients (as measured by the primary endpoint of the ROC Area Under the Curve) when aided with OsteoDetect as compared to performance at the same task without OsteoDetect, according to clinical standard of care.\\n\\nAUCaided - AUCunaided = 0.889 - 0.840= 0.049 (two sided 95% confidence level [0.019,0.080])\\n\\nOsteoDetect-aided read performance also showed statistically significant improvement as measured by sensitivity, specificity, PPV, and NPV as compared with the unaided read performance. Specifically, Imagen's study demonstrated a device-aided sensitivity of 80.3% (two sided 95% confidence interval for the mean: [78.5%,81.9%]) and device-aided specificity of 91.4% (two sided 95% confidence interval for the mean: [90.3%,92.4%]). By comparison, the study demonstrated non-aided sensitivity and specificity of 74.7% [72.8%,76.5%] and 88.9% [87.6%,90.0%], respectively.\\n\\nEarlier detection of a distal radial fracture will allow earlier intervention, potentially allowing closed reduction and casting instead of open reduction, minimizing the risk of delayed pain and post-traumatic arthritis.\"], [\"Summary of the Risk(s)\", \"There are minimal potential risks associated with use of the device, including:\\n\\n\u2022 The device could provide false positive results, which could contribute to the end user using this information to make a false positive diagnosis. Such a false positive diagnosis can result in unnecessary patient treatment or followup.\\n\\n\u2022 The device could provide false negative results, which could contribute to the end user using this information to make a false negative diagnosis. A false negative diagnosis could lead to delays in diagnosis and treatment of the fracture and increase the likelihood of negative outcomes such as incomplete fracture healing.\\n\\n\u2022 The device could be misused to analyze images from an unintended patient population or on images acquired with\"]], \"header_present\": true}], \"warnings\": [\"The header row is a single merged cell ('Summary') spanning both columns of the table; each data row contains 2 cells (a row-label cell and a content cell), so the row cell count (2) does not match the header cell count (1).\", \"The final bullet point in the 'Summary of the Risk(s)' row is cut off at the bottom of the crop; the visible text ends mid-sentence at '...on images acquired with' and the remainder of the cell content is not present in this crop.\", \"The equation in the 'Summary of the Benefit(s)' row is printed without a space before the second equals sign ('0.840= 0.049'); transcribed exactly as printed.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "Let me analyze this image. It's a table from an FDA regulatory PDF (looks like a De Novo decision summary for OsteoDetect by Imagen).\n\nThe table structure:\n- Header row: a single cell spanning both columns with \"Summary\" (gray background)\n- Row 1: \"Summary of the Benefit(s)\" | long text about clinical MRMC study\n- Row 2: \"Summary of the Risk(s)\" | text about minimal potential risks with bullet points\n\nThe header row appears to be a single merged cell \"Summary\" spanning both columns. So the table has 2 columns but the header is a single merged cell.\n\nLet me transcribe:\n\nHeader: \"Summary\" - this spans across both columns.\n\nRow 1:\n- Cell 1: \"Summary of the Benefit(s)\"\n- Cell 2: \"The clinical MRMC study demonstrated a statistically significant improvement in reader performance in detecting distal radius fracture in adult patients (as measured by the primary endpoint of the ROC Area Under the Curve) when aided with OsteoDetect as compared to performance at the same task without OsteoDetect, according to clinical standard of care.\\n\\nAUCaided - AUCunaided = 0.889 - 0.840= 0.049 (two sided 95% confidence level [0.019,0.080])\\n\\nOsteoDetect-aided read performance also showed statistically significant improvement as measured by sensitivity, specificity, PPV, and NPV as compared with the unaided read performance. Specifically, Imagen's study demonstrated a device-aided sensitivity of 80.3% (two sided 95% confidence interval for the mean: [78.5%,81.9%]) and device-aided specificity of 91.4% (two sided 95% confidence interval for the mean: [90.3%,92.4%]). By comparison, the study demonstrated non-aided sensitivity and specificity of 74.7% [72.8%,76.5%] and 88.9% [87.6%,90.0%], respectively.\\n\\nEarlier detection of a distal radial fracture will allow earlier intervention, potentially allowing closed reduction and casting instead of open reduction, minimizing the risk of delayed pain and post-traumatic arthritis.\"\n\nRow 2:\n- Cell 1: \"Summary of the Risk(s)\"\n- Cell 2: \"There are minimal potential risks associated with use of the device, including:\\n\\n\u2022 The device could provide false positive results, which could contribute to the end user using this information to make a false positive diagnosis. Such a false positive diagnosis can result in unnecessary patient treatment or followup.\\n\\n\u2022 The device could provide false negative results, which could contribute to the end user using this information to make a false negative diagnosis. A false negative diagnosis could lead to delays in diagnosis and treatment of the fracture and increase the likelihood of negative outcomes such as incomplete fracture healing.\\n\\n\u2022 The device could be misused to analyze images from an unintended patient population or on images acquired with\" (text cut off at bottom)\n\nThe last bullet is cut off at the bottom of the crop: \"The device could be misused to analyze images from an unintended patient population or on images acquired with\" \u2014 the text continues beyond the crop.\n\nNow, how to structure the JSON:\n\nThe header \"Summary\" is a merged cell spanning both columns. The columns would be... hmm. The header row has one cell \"Summary\" spanning 2 columns. So columns could be [\"Summary\"] with a note, or [\"Summary\", \"Summary\"]? \n\nPer rule 8, if rows don't have the same number of cells as the header, flag mismatch. The header has 1 cell (merged), rows have 2 cells each. I could represent columns as [\"Summary\"] and note that the header is a merged cell spanning both columns, with rows having 2 cells.\n\nAlternatively, I could treat the header as spanning and put columns: [\"Summary\", \"Summary\"]? That would be fabricating. Better: columns: [\"Summary\"], and rows with 2 cells each, with a warning about the mismatch/merged header.\n\nActually, another approach: since the header spans both columns, maybe represent it as columns: [\"Summary\"] and note in warnings that the header cell spans two columns and data rows contain two cells (row label + content).\n\nCaption: null (no caption visible).\n\nWarnings:\n- Header row is a single merged cell \"Summary\" spanning both columns; data rows have 2 cells each.\n- The last bullet point in the \"Summary of the Risk(s)\" row is cut off at the bottom of the crop; text ends mid-sentence at \"...on images acquired with\".\n- The text \"AUCaided - AUCunaided = 0.889 - 0.840= 0.049\" is printed without spaces around the second equals sign; transcribed as printed.\n\nHmm, also note \"0.840= 0.049\" \u2014 printed as \"0.840= 0.049\". I'll transcribe exactly.\n\nShould I include the full text in the cells? Yes, transcribe exactly what's printed.\n\nLet me write out the full text carefully.\n\nRow 1, cell 2 text:\n\n\"The clinical MRMC study demonstrated a statistically significant improvement in reader performance in detecting distal radius fracture in adult patients (as measured by the primary endpoint of the ROC Area Under the Curve) when aided with OsteoDetect as compared to performance at the same task without OsteoDetect, according to clinical standard of care.\n\nAUCaided - AUCunaided = 0.889 - 0.840= 0.049 (two sided 95% confidence level [0.019,0.080])\n\nOsteoDetect-aided read performance also showed statistically significant improvement as measured by sensitivity, specificity, PPV, and NPV as compared with the unaided read performance. Specifically, Imagen's study demonstrated a device-aided sensitivity of 80.3% (two sided 95% confidence interval for the mean: [78.5%,81.9%]) and device-aided specificity of 91.4% (two sided 95% confidence interval for the mean: [90.3%,92.4%]). By comparison, the study demonstrated non-aided sensitivity and specificity of 74.7% [72.8%,76.5%] and 88.9% [87.6%,90.0%], respectively.\n\nEarlier detection of a distal radial fracture will allow earlier intervention, potentially allowing closed reduction and casting instead of open reduction, minimizing the risk of delayed pain and post-traumatic arthritis.\"\n\nRow 2, cell 2 text:\n\n\"There are minimal potential risks associated with use of the device, including:\n\n\u2022 The device could provide false positive results, which could contribute to the end user using this information to make a false positive diagnosis. Such a false positive diagnosis can result in unnecessary patient treatment or followup.\n\n\u2022 The device could provide false negative results, which could contribute to the end user using this information to make a false negative diagnosis. A false negative diagnosis could lead to delays in diagnosis and treatment of the fracture and increase the likelihood of negative outcomes such as incomplete fracture healing.\n\n\u2022 The device could be misused to analyze images from an unintended patient population or on images acquired with\"\n\nThe last bullet is cut off mid-sentence.\n\nFor JSON, I'll use \\n\\n for paragraph breaks or just spaces? I'll use \"\\n\\n\" to preserve paragraph structure. Actually, to be safe, I could use single spaces or \\n. I'll use \"\\n\\n\" between paragraphs and \"\\n\u2022 \" for bullets. Let me keep it readable with \\n\\n.\n\nHeader present: true. Columns: [\"Summary\"]. But rows have 2 cells. Warning about that.\n\nAlternatively, I could consider the table as having 2 columns where the header spans. Some pipelines prefer columns to match row cell counts. But rule 7 says don't fabricate. The printed header is just \"Summary\" spanning. I'll set columns: [\"Summary\"] and add warning: \"Header row consists of a single merged cell 'Summary' spanning both columns; each data row contains 2 cells (a row-label cell and a content cell), so row cell count (2) does not match header cell count (1).\"\n\nunreadable: false.\n\nAlso note the numbers like \"0.889 - 0.840= 0.049\" \u2014 these are results, not goals. No acceptance goals here. No charts.\n\nAny OCR glyph issues? \"MRMC\" is fine. The text seems clean. No normalization needed.\n\nOne more check: \"AUCaided - AUCunaided = 0.889 - 0.840= 0.049 (two sided 95% confidence level [0.019,0.080])\" \u2014 yes that's what's printed.\n\nLet me build the JSON.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 17276,
|
| 23 |
+
"total_tokens": 19767,
|
| 24 |
+
"completion_tokens": 2491,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN180005-p22-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 38.743,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "d42ca7b0a6d3fef9d188cae998f5f03d",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639209,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [],\n \"rows\": [\n [\n \"incompatible imaging hardware or incompatible image acquisition parameters, leading to inappropriate information regarding the presence/location of a fracture being provided to the end user.\\n\\n\u2022 The device could fail and lead to absence of results, delay of results, or incorrect results, which can lead to delayed or inaccurate patient diagnosis\\n\\nHowever, based on the performance data and the application of general controls and special controls established for this device type, use of this device is unlikely to increase the rate of false negative or false positive diagnoses of distal radius fracture as compared with the current clinical standard of practice. Further, possible misuse of the device does not present additional risks compared with the misuse of other types of radiological image processing devices.\"\n ],\n [\n \"Summary of Other Factors\",\n \"Currently, injuries to the hand and wrist account for approximately 20% of visits to the emergency department, with a total of approximately 3.5 million hand and wrist injuries noted in 2009, for an incidence of 1130 injuries per 100,000 persons per year. (Hand (NY) 2012; 7:18-22) By detecting a potentially occult distal radial fracture earlier, pain, post-traumatic arthritis, and possible disability are alleviated, resulting in a potential significant improvement in US public health.\\n\\nThis software tool brings the expertise of musculoskeletal radiologists and orthopaedic surgeons specializing in hand surgery to emergency medicine physicians and physician assistants, family practice physicians, and internal medicine physicians. Therefore, subspecialty expertise is potentially available to emergency rooms across the country with the use of this software device.\"\n ],\n [\n \"Conclusions\\nDo the probable benefits outweigh the probable risks?\",\n \"The benefited population would include adult patients with clinically suspected distal radius fracture. This software potentially brings subspecialty expertise of musculoskeletal radiologists and orthopaedic surgeons specializing in hand and wrist surgery to physicians and physician assistants working in emergency rooms across the country.\\n\\nThe underlying statistics as discussed above justify that the performance of the device has been clinically validated in a fully crossed design. The 4 types of clinical providers (emergency medicine physicians, emergency medicine physician assistants, family medicine physicians, and internal medicine physicians) most likely to staff emergency rooms were separately evaluated, and all showed improvement in the detection of a distal radial fracture aided by the device. Given that the standard of care in 2018 is to cast and have a follow-up X-ray in 10-14 days or perform an MRI in cases where a distal radial fracture is clinically suspected in\"\n ]\n ],\n \"header_present\": false\n }\n ],\n \"warnings\": [\n \"Row 1 appears to lack a left-hand label cell; it may be a continuation from a prior row or section. Transcribed as-is without assuming a header or label.\",\n \"Row 2 and Row 3 contain multi-line text blocks spanning multiple paragraphs. These are transcribed as single cells per column as visually presented.\",\n \"The table appears to be a two-column layout with left column acting as row labels and right column as content. No explicit header row is visible in the crop, so header_present is set to false and columns array is empty per Rule 7.\"\n ],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3159,
|
| 21 |
+
"completion_tokens": 717,
|
| 22 |
+
"total_tokens": 3876,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2496,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 717,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN190040-p11-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 13.372,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "9f9b9bd51de79219123c35d9b74186c3",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639184,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [],\n \"rows\": [\n [\n \"Device Error \u2013 Failure to provide guidance on acquiring diagnostic-quality images or signals, leading to delay, prolonged examination, or additional unnecessary procedures, due to:\\n\u2022 Algorithm failure\\n\u2022 Hardware or software failure\",\n \"\u2022 Design verification and validation\\n\u2022 Labeling\"\n ],\n [\n \"User Error \u2013 Operator failure to follow the guidance provided by the device to acquire diagnostic-quality images or signals, leading to delay, prolonged examination, or additional unnecessary procedures, due to human error\",\n \"\u2022 Design verification and validation\\n\u2022 Labeling\"\n ]\n ],\n \"header_present\": false\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3173,
|
| 21 |
+
"completion_tokens": 166,
|
| 22 |
+
"total_tokens": 3339,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2510,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 166,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN190040-p11-t1__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 20.374,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "b472f6e7a665972bfe3ad93f296160b8",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639191,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": \"Benefit/Risk Summary\",\n \"columns\": [\"Summary of Benefits\", \"Summary of Risks\"],\n \"rows\": [\n [\n \"Summary of Benefits\",\n \"Echocardiography is a highly valuable method for assessment of various structural and functional characteristics of the heart. Additionally, with the development of point-of-care ultrasound imaging, echocardiography at the bedside could provide a valuable first line of cardiac assessment in settings outside of a traditional cardiology department, or hospitals. Caption Guidance is a tool to fulfill this important clinical need.\\n\\nEchocardiography is highly operator-dependent, and the training for echocardiography takes a significant amount of time, leading to a shortage of skilled cardiac sonographers. Caption Guidance provides a tool to enable non-cardiac sonographers to acquire standard echocardiography images that can be later reviewed by an expert cardiac healthcare professional. The pivotal study for non-users of cardiac ultrasound was significant and clinically meaningful.\\n\\nEchocardiography is a highly operator-dependent imaging modality, and there is variation of echocardiograms\u2019 quality. Caption Guidance is a tool to address the variability of echocardiograms\u2019 quality by providing a quantitative image quality metric.\"\n ],\n [\n \"Summary of Risks\",\n \"Low-quality images from software/algorithm error, hardware error, or user error, leading to additional unnecessary examinations, and/or delay of diagnosis.\"\n ]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3195,
|
| 21 |
+
"completion_tokens": 330,
|
| 22 |
+
"total_tokens": 3525,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2532,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 330,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN190040-p6-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 14.005,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "3bdc0d361ad28a7f320732066b1e5286",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639184,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"#\", \"Clinical Parameter\", \"% of Scans of Sufficient Quality (MRMC CI)\"], \"rows\": [[\"1\", \"Qualitative Visual Assessment of Left Ventricular Size\", \"98.8%\\n(96.7%, 100%)\"], [\"2\", \"Qualitative Visual Assessment of Global Left Ventricular Function\", \"98.8%\\n(96.7%, 100%)\"], [\"3\", \"Qualitative Visual Assessment of Right Ventricular Size\", \"92.5%\\n(88.1%, 96.9%)\"], [\"4\", \"Qualitative Visual Assessment of Non-Trivial Pericardial Effusion\", \"98.8%\\n(96.7%, 100%)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3176,
|
| 21 |
+
"completion_tokens": 191,
|
| 22 |
+
"total_tokens": 3367,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2513,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 191,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN190040-p6-t1__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 15.927,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "bd60c84702085b589bd11b79bf50e8d2",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639186,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"#\", \"Clinical Parameter\", \"% of Scans of Sufficient Quality (MRMC 95% CI)\"], \"rows\": [[\"1\", \"Qualitative visual assessment of inferior vena cava size\", \"57.5%\\n(41.5%, 73.5%)\"], [\"2\", \"Qualitative visual assessment of right ventricular function\", \"91.3%\\n(85.7%, 96.8%)\"], [\"3\", \"Qualitative visual assessment of left atrial size\", \"94.6%\\n(90.7%, 98.5%)\"], [\"4\", \"Qualitative visual assessment of aortic valve\", \"91.7%\\n(88.0%, 95.3%)\"], [\"5\", \"Qualitative visual assessment of mitral valve\", \"96.3%\\n(93.9%, 98.6%)\"], [\"6\", \"Qualitative visual assessment of tricuspid valve\", \"83.3%\\n(77.0%, 89.7%)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3185,
|
| 21 |
+
"completion_tokens": 260,
|
| 22 |
+
"total_tokens": 3445,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2522,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 260,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN190040-p7-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 17.403,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "ad97bec24044f9fbcadfa9b0232449b0",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639188,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"#\", \"View\", \"% of Clips of Diagnostic Quality [MRMC CI]\"], \"rows\": [[\"1\", \"PLAX\", \"92.1%\\n(87.9%, 96.3%)\"], [\"2\", \"PSAX-AV\", \"66.3%\\n(59.0%, 73.5%)\"], [\"3\", \"PSAX-MV\", \"75.8%\\n(70.7%, 80.9%)\"], [\"4\", \"PSAX-PM\", \"92.9%\\n(89.1%, 96.7%)\"], [\"5\", \"AP4\", \"88.8%\\n(81.5%, 96.0%)\"], [\"6\", \"AP5\", \"78.8%\\n(66.9%, 90.6%)\"], [\"7\", \"AP3\", \"80.0%\\n(70.4%, 89.7%)\"], [\"8\", \"AP2\", \"71.3%\\n(61.6%, 80.9%)\"], [\"9\", \"SubC4\", \"76.3%\\n(70.2%, 82.3%)\"], [\"10\", \"SC-IVC\", \"59.2%\\n(43.1%, 75.2%)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3202,
|
| 21 |
+
"completion_tokens": 329,
|
| 22 |
+
"total_tokens": 3531,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2539,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 329,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN190040-p7-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 27.844,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb114-6e0566b15c19861f3323320f-chatcmpl-7559101",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639191,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"#\", \"View\", \"% of Clips of Diagnostic Quality [MRMC CI]\"], \"rows\": [[\"1\", \"PLAX\", \"92.1% (87.9%, 96.3%)\"], [\"2\", \"PSAX-AV\", \"66.3% (59.0%, 73.5%)\"], [\"3\", \"PSAX-MV\", \"75.8% (70.7%, 80.9%)\"], [\"4\", \"PSAX-PM\", \"92.9% (89.1%, 96.7%)\"], [\"5\", \"AP4\", \"88.8% (81.5%, 96.0%)\"], [\"6\", \"AP5\", \"78.8% (66.9%, 90.6%)\"], [\"7\", \"AP3\", \"80.0% (70.4%, 89.7%)\"], [\"8\", \"AP2\", \"71.3% (61.6%, 80.9%)\"], [\"9\", \"SubC4\", \"76.3% (70.2%, 82.3%)\"], [\"10\", \"SC-IVC\", \"59.2% (43.1%, 75.2%)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "The image shows a table with three columns: \"#\", \"View\", and \"% of Clips of Diagnostic Quality [MRMC CI]\". There are 10 rows. Each row has a number, a view name, and a percentage with CI in parentheses. The header is present. No caption visible. The estimate with CI should be kept as one cell string, e.g., \"92.1% (87.9%, 96.3%)\".\n\nLet me transcribe:\n\n1 PLAX 92.1% (87.9%, 96.3%)\n2 PSAX-AV 66.3% (59.0%, 73.5%)\n3 PSAX-MV 75.8% (70.7%, 80.9%)\n4 PSAX-PM 92.9% (89.1%, 96.7%)\n5 AP4 88.8% (81.5%, 96.0%)\n6 AP5 78.8% (66.9%, 90.6%)\n7 AP3 80.0% (70.4%, 89.7%)\n8 AP2 71.3% (61.6%, 80.9%)\n9 SubC4 76.3% (70.2%, 82.3%)\n10 SC-IVC 59.2% (43.1%, 75.2%)\n\nHeader: \"#\", \"View\", \"% of Clips of Diagnostic Quality [MRMC CI]\"\n\nNo warnings needed really. Caption null. header_present true.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 9546,
|
| 23 |
+
"total_tokens": 10186,
|
| 24 |
+
"completion_tokens": 640,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/DEN230023-p5-t0__primary.json
ADDED
|
@@ -0,0 +1,8 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 23.545,
|
| 3 |
+
"status_code": 413,
|
| 4 |
+
"body": {
|
| 5 |
+
"error": "request entity too large"
|
| 6 |
+
},
|
| 7 |
+
"error": null
|
| 8 |
+
}
|
data/vlm_run/raw/pass_a/DEN230023-p5-t0__secondpass.json
ADDED
|
@@ -0,0 +1,8 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 4.741,
|
| 3 |
+
"status_code": 413,
|
| 4 |
+
"body": {
|
| 5 |
+
"error": "request entity too large"
|
| 6 |
+
},
|
| 7 |
+
"error": null
|
| 8 |
+
}
|
data/vlm_run/raw/pass_a/DEN240047-p10-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 37.225,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "1e4e523c7596179b94c7a254ebd8a78b",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639208,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [\n \"Study Population\",\n \"Exams\",\n \"Discrimination: AUC(5) [95% CIs]\",\n \"Calibration: GND Test Statistic\",\n \"Calibration: Non-centrality parameter\",\n \"Calibration: P value\"\n ],\n \"rows\": [\n [\n \"Formally-Tested Endpoints\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Total Study Population\",\n \"77,511\",\n \"0.70 [0.69, 0.72]\",\n \"21.70\",\n \"121.25\",\n \"< .0001\"\n ],\n [\n \"Excluding Current Cancers\",\n \"77,072\",\n \"0.66 [0.66, 0.68]\",\n \"95.27\",\n \"132.08\",\n \"0.0174\"\n ],\n [\n \"Sub-group Analyses (Total Study Population)\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Race & Ethnicity\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Asian\",\n \"5,735\",\n \"0.72 [0.67, 0.77]\",\n \"13.45\",\n \"11.80\",\n \"0.1830\"\n ],\n [\n \"Black\",\n \"28,931\",\n \"0.67 [0.65, 0.69]\",\n \"24.81\",\n \"43.29\",\n \"0.0107\"\n ],\n [\n \"White\",\n \"34,743\",\n \"0.73 [0.71, 0.74]\",\n \"26.92\",\n \"56.06\",\n \"0.0016\"\n ],\n [\n \"Hispanic\",\n \"7,617\",\n \"0.70 [0.64, 0.75]\",\n \"7.99\",\n \"14.37\",\n \"0.0139\"\n ],\n [\n \"Age Group\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"<50\",\n \"20,156\",\n \"0.68 [0.66, 0.72]\",\n \"24.66\",\n \"34.43\",\n \"0.0498\"\n ],\n [\n \"\u226550, <65\",\n \"35,310\",\n \"0.69 [0.67, 0.71]\",\n \"9.33\",\n \"54.35\",\n \"0.0000\"\n ],\n [\n \"\u226565\",\n \"22,045\",\n \"0.68 [0.66, 0.70]\",\n \"46.80\",\n \"38.11\",\n \"0.5202\"\n ],\n [\n \"Breast Density\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Dense\",\n \"30,912\",\n \"0.69 [0.67, 0.71]\",\n \"26.17\",\n \"42.88\",\n \"0.0168\"\n ],\n [\n \"Not Dense\",\n \"44,627\",\n \"0.71 [0.69, 0.73]\",\n \"20.99\",\n \"83.14\",\n \"< .0001\"\n ],\n [\n \"Breast Implants\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Present\",\n \"1,738\",\n \"0.73 [0.59, 0.87]\",\n \"5.46\",\n \"2.08\",\n \"0.1153\"\n ],\n [\n \"Not Present\",\n \"75,773\",\n \"0.70 [0.69, 0.72]\",\n \"22.30\",\n \"119.48\",\n \"< .0001\"\n ],\n [\n \"Mammography Model\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Lorad Selenia\",\n \"22,093\",\n \"0.72 [0.70, 0.75]\",\n \"9.89\",\n \"42.04\",\n \"< .0001\"\n ],\n [\n \"Selenia Dimensions\",\n \"55,491\",\n \"0.70 [0.68, 0.72]\",\n \"29.01\",\n \"77.52\",\n \"< .0001\"\n ]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3165,
|
| 21 |
+
"completion_tokens": 1179,
|
| 22 |
+
"total_tokens": 4344,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2502,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 1179,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN240047-p12-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 32.054,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "c59a21ec9cded2a3da7bf3a12fe3c081",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639202,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [\n \"Study Population\",\n \"Exams\",\n \"AUC(5) [95% CIs]\",\n \"GND Test Statistic\",\n \"Non-centrality parameter\",\n \"P value\"\n ],\n \"rows\": [\n [\n \"Sub-group Analyses (Excluding Current Cancers)\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Race & Ethnicity\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Asian\",\n \"5,708\",\n \"0.69 [0.63, 0.77]\",\n \"23.27\",\n \"13.40\",\n \"0.5834\"\n ],\n [\n \"Black\",\n \"28,761\",\n \"0.63 [0.59, 0.66]\",\n \"61.04\",\n \"49.58\",\n \"0.5915\"\n ],\n [\n \"White\",\n \"34,521\",\n \"0.68 [0.66, 0.70]\",\n \"41.64\",\n \"62.84\",\n \"0.0209\"\n ],\n [\n \"Hispanic\",\n \"7,589\",\n \"0.67 [0.61, 0.73]\",\n \"23.46\",\n \"16.21\",\n \"0.4636\"\n ],\n [\n \"Age Group\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"<50\",\n \"20,091\",\n \"0.64 [0.60, 0.67]\",\n \"73.20\",\n \"38.84\",\n \"0.9622\"\n ],\n [\n \"\u226550, <65\",\n \"35,124\",\n \"0.65 [0.63, 0.68]\",\n \"56.09\",\n \"60.99\",\n \"0.1991\"\n ],\n [\n \"\u226565\",\n \"21,857\",\n \"0.64 [0.61, 0.66]\",\n \"69.98\",\n \"50.61\",\n \"0.7680\"\n ],\n [\n \"Breast Density\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Dense\",\n \"30,720\",\n \"0.65 [0.62, 0.67]\",\n \"31.47\",\n \"43.83\",\n \"0.0475\"\n ],\n [\n \"Not Dense\",\n \"44,383\",\n \"0.67 [0.65, 0.69]\",\n \"79.19\",\n \"90.53\",\n \"0.1466\"\n ],\n [\n \"Breast Implants\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Present\",\n \"1,733\",\n \"0.63 [0.49, 0.76]\",\n \"8.88\",\n \"2.50\",\n \"0.3508\"\n ],\n [\n \"Not Present\",\n \"75,339\",\n \"0.66 [0.65, 0.68]\",\n \"105.34\",\n \"135.85\",\n \"0.0394\"\n ],\n [\n \"Mammography Model\",\n \"\",\n \"\",\n \"\",\n \"\",\n \"\"\n ],\n [\n \"Lorad Selenia\",\n \"21,975\",\n \"0.68 [0.65, 0.71]\",\n \"55.57\",\n \"48.34\",\n \"0.4781\"\n ],\n [\n \"Selenia Dimensions\",\n \"55,164\",\n \"0.66 [0.64, 0.68]\",\n \"47.24\",\n \"82.14\",\n \"0.0035\"\n ]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3185,
|
| 21 |
+
"completion_tokens": 1025,
|
| 22 |
+
"total_tokens": 4210,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2522,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 1025,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN240047-p14-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 16.902,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "97af9e028e9ef69a7bedc1e763753517",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639187,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Decile\", \"Mean model prediction\", \"Observed Turnbull estimate\", \"Calibration error (95% CI)\"], \"rows\": [[\"1\", \"0.91%\", \"0.67%\", \"0.23% (0.01%, 0.45%)\"], [\"2\", \"1.14%\", \"1.19%\", \"-0.05% (-0.34%, 0.24%)\"], [\"3\", \"1.41%\", \"1.32%\", \"0.09% (-0.24%, 0.42%)\"], [\"4\", \"1.68%\", \"1.85%\", \"-0.17% (-0.52%, 0.18%)\"], [\"5\", \"1.99%\", \"2.54%\", \"-0.55% (-1.00%, -0.10%)\"], [\"6\", \"2.33%\", \"2.72%\", \"-0.39% (-0.94%, 0.16%)\"], [\"7\", \"2.91%\", \"3.20%\", \"-0.29% (-0.80%, 0.22%)\"], [\"8\", \"3.63%\", \"4.31%\", \"-0.68% (-1.27%, -0.09%)\"], [\"9\", \"4.48%\", \"4.94%\", \"-0.45% (-1.10%, 0.20%)\"], [\"10\", \"9.05%\", \"9.19%\", \"-0.14% (-0.87%, 0.59%)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3185,
|
| 21 |
+
"completion_tokens": 399,
|
| 22 |
+
"total_tokens": 3584,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2522,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 399,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN240047-p14-t1__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 18.089,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "e2c12b56dfa9c30b6598ca625865e956",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639188,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Decile\", \"Mean model prediction\", \"Observed Turnbull estimate\", \"Calibration error (95% CI)\"], \"rows\": [[\"1\", \"0.91%\", \"0.64%\", \"0.27% (0.05%, 0.49%)\"], [\"2\", \"1.14%\", \"1.08%\", \"0.06% (-0.23%, 0.35%)\"], [\"3\", \"1.41%\", \"1.10%\", \"0.31% (-0.02%, 0.64%)\"], [\"4\", \"1.68%\", \"1.80%\", \"-0.12% (-0.47%, 0.23%)\"], [\"5\", \"1.99%\", \"2.34%\", \"-0.35% (-0.76%, 0.06%)\"], [\"6\", \"2.32%\", \"2.37%\", \"-0.05% (-0.56%, 0.46%)\"], [\"7\", \"2.89%\", \"2.74%\", \"0.15% (-0.32%, 0.62%)\"], [\"8\", \"3.61%\", \"3.75%\", \"-0.14% (-0.75%, 0.47%)\"], [\"9\", \"4.45%\", \"4.24%\", \"0.21% (-0.42%, 0.84%)\"], [\"10\", \"8.65%\", \"5.73%\", \"2.92% (2.29%, 3.55%)\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3185,
|
| 21 |
+
"completion_tokens": 399,
|
| 22 |
+
"total_tokens": 3584,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2522,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 399,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN240047-p16-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 18.477,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "2916bcf4d0670a68960d426720e405a0",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639189,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Risks to Health\", \"Mitigation Measures\"], \"rows\": [[\"Device provides inaccurate risk discrimination and/or calibration contributing to:\\n\u2022 Falsely high risk output, leading to patients receiving unnecessary additional imaging or preventive risk reduction measures\\n\u2022 Falsely low risk output, leading to patients not receiving additional imaging or preventive risk reduction measures\", \"Clinical performance testing\\nSoftware verification, validation, and hazard analysis\\nLabeling\\nPostmarket monitoring plan\"], [\"Inconsistent device output due to differences in acquisition, equipment settings, or other factors affecting image selection or quality\", \"Clinical performance testing\\nSoftware verification, validation and hazard analysis\\nLabeling\\nPostmarket monitoring plan\"], [\"User misinterpretation of device result(s) contributing to:\\n\u2022 Inappropriate categorization of patient risk resulting in erroneous patient management decisions related to additional imaging or preventive risk reduction measures\\n\u2022 Overreliance on device output\\nPatient misinterpretation of device result(s) contributing to\\n\u2022 Considering low risk to be negligible which may contribute to not receiving standard-of-care screening or preventive risk reduction measures\", \"Labeling\\nPostmarket monitoring plan\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3161,
|
| 21 |
+
"completion_tokens": 255,
|
| 22 |
+
"total_tokens": 3416,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2498,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 255,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN240047-p4-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 15.391,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "c8db79019913688d4944db4d14f98b04",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639186,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Patient Demographics and Other Characteristics\", \"Training Dataset (number of exams)\"], \"rows\": [[\"Age\", \"\"], [\"Age < 50\", \"73,500\"], [\"50 \u2264 Age < 65\", \"208,865\"], [\"Age \u2265 65\", \"83,551\"], [\"Race\", \"\"], [\"White\", \"225,309\"], [\"Black\", \"20,862\"], [\"Asian\", \"9,230\"], [\"Indian\", \"553\"], [\"Hawaiian\", \"440\"], [\"Unknown\", \"109,654\"], [\"BI-RADS\", \"\"], [\"Positive\", \"32,928\"], [\"Negative\", \"244,940\"], [\"Unknown\", \"8,8045\"], [\"Breast Density\", \"\"], [\"Dense\", \"170,398\"], [\"Not Dense\", \"160,974\"], [\"Unknown\", \"34,544\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3165,
|
| 21 |
+
"completion_tokens": 256,
|
| 22 |
+
"total_tokens": 3421,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2502,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 256,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN250007-p2-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 7.661,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "a8e32be37c0d5bd09afd02cc31c7ad03",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639178,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Risks to Health\", \"Mitigation Measures\"], \"rows\": [[\"Inappropriate patient management due to inaccurate prediction of actual delivery date, whether significantly early or late\", \"Clinical performance testing\\nSoftware verification, validation, and hazard analysis\\nLabeling\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 2933,
|
| 21 |
+
"completion_tokens": 80,
|
| 22 |
+
"total_tokens": 3013,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2270,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 80,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/DEN250007-p3-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 12.841,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "f355a059cf80cd0530a63aa6aac90639",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639183,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"Risks to Health\", \"Mitigation Measures\"], \"rows\": [[\"Postmarket monitoring plan\", \"Postmarket monitoring plan\"], [\"Inappropriate patient management resulting from inconsistent device output due to differences in acquisitions, equipment settings, and other image input characteristics\", \"Clinical performance testing\\nSoftware verification, validation, and hazard analysis\\nLabeling\\nPostmarket monitoring plan\"], [\"User misinterpretation of the device\u2019s output as being directly reflective of the gestational age of the fetus, contributing to:\\n- Inappropriate patient management\\n- Overreliance on device output\", \"Labeling\\nDevice Characteristics\"]], \"header_present\": true}], \"warnings\": [], \"unreadable\": false}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3193,
|
| 21 |
+
"completion_tokens": 151,
|
| 22 |
+
"total_tokens": 3344,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2530,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 151,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p4-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 20.467,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "b9198e34c90ce5ece98197e2d3d789b2",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639191,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": \"510(k) Summary (As required by Section 21 CFR 807.92(c))\",\n \"columns\": [\"Field\", \"Value\"],\n \"rows\": [\n [\"Submitter:\", \"Imbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\"],\n [\"Contact Person:\", \"Jason Sheard\\nDirector of Operations\\nTelephone: 612-520-7360\\nEmail: jasonsheard@imbio.com\\n\\nImbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\"],\n [\"Date Prepared:\", \"August 14, 2014\"],\n [\"Trade Name:\", \"Imbio CT Lung Density Analysis Software\"],\n [\"Common/Usual Name:\", \"Software Accessory to a Computed Tomography Device\"],\n [\"Classification:\", \"21 CFR 892.1750\\nProduct Code 90 JAK, Class II\\nComputed tomography x-ray system\"],\n [\"Product Code:\", \"90 JAK, Class II\"],\n [\"Manufacturer:\", \"Imbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\"],\n [\"Establishment Registration:\", \"N/A\"],\n [\"Predicate Device:\", \"Manufacturer: VIDA Diagnostics\\nTrade name: VIDA Pulmonary Workstation 2 (PW2)\\n510(k) Number: K083227\\nDate Cleared: November 18, 2008\"]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3165,
|
| 21 |
+
"completion_tokens": 389,
|
| 22 |
+
"total_tokens": 3554,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2502,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 389,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p4-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 28.807,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb118-5e8937f16bd540ae4b9af93e-chatcmpl-f710592",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639195,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"510(k) Summary (As required by Section 21 CFR 807.92(c))\", \"columns\": [], \"rows\": [[\"Submitter:\", \"Imbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\"], [\"Contact Person:\", \"Jason Sheard\\nDirector of Operations\\nTelephone: 612-520-7360\\nEmail: jasonsheard@imbio.com\\n\\nImbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\"], [\"Date Prepared:\", \"August 14, 2014\"], [\"Trade Name:\", \"Imbio CT Lung Density Analysis Software\"], [\"Common/Usual Name:\", \"Software Accessory to a Computed Tomography Device\"], [\"Classification:\", \"21 CFR 892.1750\\nProduct Code 90 JAK, Class II\\nComputed tomography x-ray system\"], [\"Product Code:\", \"90 JAK, Class II\"], [\"Manufacturer:\", \"Imbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\"], [\"Establishment Registration:\", \"N/A\"], [\"Predicate Device:\", \"Manufacturer: VIDA Diagnostics\\nTrade name: VIDA Pulmonary Workstation 2 (PW2)\\n510(k) Number: K083227\\nDate Cleared: November 18, 2008\"]], \"header_present\": false}], \"warnings\": [\"No printed column header row in this crop; the top row is a spanning title ('510(k) Summary (As required by Section 21 CFR 807.92(c))') and was captured as the caption. Table is a two-column label/value layout; per instructions columns is empty and header_present is false.\", \"Several value cells contain multiple printed lines; line breaks are preserved as newline characters within the single cell string.\", \"The 'Predicate Device' value cell contains its own printed sub-labels (Manufacturer:, Trade name:, 510(k) Number:, Date Cleared:) which were transcribed as printed within the single cell.\", \"The email address 'jasonsheard@imbio.com' is printed as a hyperlink; transcribed as plain text.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "The image shows a 510(k) Summary table. It's a two-column layout: label column and value column. There's a title row \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" which spans both columns \u2014 that's more like a caption/title.\n\nThe table has no printed header row with column names \u2014 the first row is a title. The rows are label-value pairs. Per rule 7, if no header row is visibly printed, set header_present: false and columns: []. But wait \u2014 the first row \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" is a title spanning the table. I could treat it as a caption.\n\nLet me structure: caption = \"510(k) Summary (As required by Section 21 CFR 807.92(c))\". header_present = false, columns = []. Rows are the label-value pairs.\n\nRows:\n1. Submitter: | Imbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\n2. Contact Person: | Jason Sheard\\nDirector of Operations\\nTelephone: 612-520-7360\\nEmail: jasonsheard@imbio.com\\n\\nImbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\n3. Date Prepared: | August 14, 2014\n4. Trade Name: | Imbio CT Lung Density Analysis Software\n5. Common/Usual Name: | Software Accessory to a Computed Tomography Device\n6. Classification: | 21 CFR 892.1750\\nProduct Code 90 JAK, Class II\\nComputed tomography x-ray system\n7. Product Code: | 90 JAK, Class II\n8. Manufacturer: | Imbio LLC\\n227 Colfax Ave N, Suite 144\\nMinneapolis MN 55405 USA\n9. Establishment Registration: | N/A\n10. Predicate Device: | Manufacturer: VIDA Diagnostics\\nTrade name: VIDA Pulmonary Workstation 2 (PW2)\\n510(k) Number: K083227\\nDate Cleared: November 18, 2008\n\nFor multi-line cells, I'll join with newline characters \"\\n\" in the string.\n\nWarnings: note that the table has no printed header; the title row treated as caption. Also note the Predicate Device cell contains sub-labels. Maybe note multi-line cells preserved with newlines.\n\nThe email is a hyperlink but text is readable: jasonsheard@imbio.com.\n\nI'll produce JSON.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 16748,
|
| 23 |
+
"total_tokens": 17760,
|
| 24 |
+
"completion_tokens": 1012,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p5-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 21.857,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "cef86ee8b046940168293701c4685aed",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639192,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": \"510(k) Summary (As required by Section 21 CFR 807.92(c))\",\n \"columns\": [\"Device Description\", \"Intended Use\"],\n \"rows\": [\n [\n \"The Imbio CT Lung Density Analysis Software (Imbio LDA) is a set of image post-processing algorithms that perform image segmentation, registration, thresholding, and classification on CT images of human lungs. The algorithms within the Imbio CT Lung Density Analysis Software are combined into a single command-line executable program that may be run directly from the command-line or through scripting. The Imbio CT Lung Density Analysis Software program performs segmentation, then registration, then thresholding and classification. The program reads in DICOM datasets, processes the data, then writes output DICOM files to a specified directory. The Imbio CT Lung Density Analysis Software is a command-line software application that analyzes DICOM CT lung image datasets and generates reports and DICOM output that show the lungs segmented and overlaid with color-codings representing the results of its thresholding and classification rules. It has simple file management functions for input and output, and separate modules that implement the CT image-processing algorithms. Imbio CT Lung Density Analysis Software does not interface directly with any CT or data collection equipment; instead the software imports data files previously generated by such equipment.\",\n \"The Imbio CT Lung Density Analysis Software provides reproducible CT values for pulmonary tissue, which is essential for providing quantitative support for diagnosis and follow up examinations. The Imbio CT Lung Density Analysis Software can be used to support the physician in the diagnosis and documentation of pulmonary tissue images (e.g., abnormalities) from CT thoracic datasets. Three-D segmentation and isolation of sub-compartments, volumetric analysis, density evaluations, and reporting tools are provided.\"\n ]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3213,
|
| 21 |
+
"completion_tokens": 405,
|
| 22 |
+
"total_tokens": 3618,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2550,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 405,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p5-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 31.515,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb11a-4e88ae1d0977d3bc4689b7d3-chatcmpl-3182a20",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639195,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"510(k) Summary (As required by Section 21 CFR 807.92(c))\", \"columns\": [], \"rows\": [[\"Device Description\", \"The Imbio CT Lung Density Analysis Software (Imbio LDA) is a set of image post-processing algorithms that perform image segmentation, registration, thresholding, and classification on CT images of human lungs. The algorithms within the Imbio CT Lung Density Analysis Software are combined into a single command-line executable program that may be run directly from the command-line or through scripting. The Imbio CT Lung Density Analysis Software program performs segmentation, then registration, then thresholding and classification. The program reads in DICOM datasets, processes the data, then writes output DICOM files to a specified directory. The Imbio CT Lung Density Analysis Software is a command-line software application that analyzes DICOM CT lung image datasets and generates reports and DICOM output that show the lungs segmented and overlaid with color-codings representing the results of its thresholding and classification rules. It has simple file management functions for input and output, and separate modules that implement the CT image-processing algorithms. Imbio CT Lung Density Analysis Software does not interface directly with any CT or data collection equipment; instead the software imports data files previously generated by such equipment.\"], [\"Intended Use\", \"The Imbio CT Lung Density Analysis Software provides reproducible CT values for pulmonary tissue, which is essential for providing quantitative support for diagnosis and follow up examinations. The Imbio CT Lung Density Analysis Software can be used to support the physician in the diagnosis and documentation of pulmonary tissue images (e.g., abnormalities) from CT thoracic datasets. Three-D segmentation and isolation of sub-compartments, volumetric analysis, density evaluations, and reporting tools are provided.\"]], \"header_present\": false}], \"warnings\": [\"The top banner row '510(k) Summary (As required by Section 21 CFR 807.92(c))' spans the full table width and was captured as the caption; no column header row is printed in this crop, so header_present is false and columns is empty.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "The image shows a 510(k) Summary table with a header row \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" spanning the top, then two rows: \"Device Description\" and \"Intended Use\" with long text in the right column.\n\nThe header row appears to be a title/caption-like row spanning both columns. It's a single cell spanning the table width. Should I treat it as a header? It says \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" \u2014 this is more like a caption/title. The table itself has two columns: label and content, but no printed column headers like \"Section\" / \"Description\". So header_present should be false, columns: []. The top banner could be the caption.\n\nRows:\n1. [\"Device Description\", \"The Imbio CT Lung Density Analysis Software (Imbio LDA) is a set of image post-processing algorithms that perform image segmentation, registration, thresholding, and classification on CT images of human lungs. The algorithms within the Imbio CT Lung Density Analysis Software are combined into a single command-line executable program that may be run directly from the command-line or through scripting. The Imbio CT Lung Density Analysis Software program performs segmentation, then registration, then thresholding and classification. The program reads in DICOM datasets, processes the data, then writes output DICOM files to a specified directory. The Imbio CT Lung Density Analysis Software is a command-line software application that analyzes DICOM CT lung image datasets and generates reports and DICOM output that show the lungs segmented and overlaid with color-codings representing the results of its thresholding and classification rules. It has simple file management functions for input and output, and separate modules that implement the CT image-processing algorithms. Imbio CT Lung Density Analysis Software does not interface directly with any CT or data collection equipment; instead the software imports data files previously generated by such equipment.\"]\n\n2. [\"Intended Use\", \"The Imbio CT Lung Density Analysis Software provides reproducible CT values for pulmonary tissue, which is essential for providing quantitative support for diagnosis and follow up examinations. The Imbio CT Lung Density Analysis Software can be used to support the physician in the diagnosis and documentation of pulmonary tissue images (e.g., abnormalities) from CT thoracic datasets. Three-D segmentation and isolation of sub-compartments, volumetric analysis, density evaluations, and reporting tools are provided.\"]\n\nCaption: \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" \u2014 it's a banner row. I'll use it as caption.\n\nWarnings: note that the top banner row spans both columns and was treated as caption; no column headers printed.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 15740,
|
| 23 |
+
"total_tokens": 16754,
|
| 24 |
+
"completion_tokens": 1014,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p6-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 16.662,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "a71bd4b1d0087dfdf57e8a7f21818ef3",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639187,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3217,
|
| 21 |
+
"completion_tokens": 20,
|
| 22 |
+
"total_tokens": 3237,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2554,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 20,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p6-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 96.958,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb114-0aa5cfb72f981a86533de143-chatcmpl-ce6caa3",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639190,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": null, \"columns\": [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\"], \"rows\": [[\"Summary of Technical Comparisons\", \"Similarities:\\nBoth the predicate device and the Imbio CT Lung Density Analysis Software are software applications that import CT DICOM data files, analyze them, and produce reports with quantitative and graphical results. The functionality of Imbio CT Lung Density Analysis Software is substantially equivalent to the predicate device. Direct quantitative comparisons using the same CT lung scans yielded similar results.\\n\\nDifferences:\\nThe Imbio Lung Density Analysis Software provides a command-line interface, while the predicate device provides a graphic user interface. The Imbio Lung Density Analysis Software provides automated registration of the Inspiration / Expiration image pairs, while this registration is manual (i.e., visually performed by the radiologist) with the predicate device. The predicate device provides an interactive visualization of the reconstructed three-dimensional volume, low-density cluster analysis, and an airway report. These features are not part of the Imbio CT Lung Density Analysis Software. These differences do not affect the efficacy and safety of the Imbio CT Lung Density Analysis Software.\"], [\"Non-Clinical Testing\", \"The following testing was conducted on Imbio CT Lung Density Analysis Software by analyzing CT datasets available upon request from the COPDGene study (www.copdgene.org) and the DIR-Lab (www.dir-lab.com):\\n\u2022 Direct predicate comparison for scan processing completion, segmentation, and thresholding. This was done to verify that the software functions according to its specifications and to support substantial equivalence.\\n\u2022 Software verification and validation testing for each requirement specification.\\n\u2022 Software verification and validation testing for each algorithmic function.\\n\u2022 Software verification and validation testing at the unit, integration, and system level\\n\\nThe following quality assurance measures were applied during software development:\\n\u2022 Software Development Life Cycle\\n\u2022 Software Risk Assessment.\\n\u2022 Risk Assessment of Off-the-Shelf (OTS) Software.\\n\u2022 Software Configuration Management and Version Control.\\n\u2022 Software issue tracking and resolution.\"]], \"header_present\": true}], \"warnings\": [\"The header row is a single merged cell spanning the full table width ('510(k) Summary (As required by Section 21 CFR 807.92(c))'), while each body row contains 2 cells (a left label cell and a right content cell); cell counts therefore differ between the header and the body rows.\", \"The URL 'www.dir-lab.com' is printed split across a line break as 'www.dir-' / 'lab.com'; it has been transcribed joined as 'www.dir-lab.com'.\", \"Bullet list items within the 'Non-Clinical Testing' content cell are transcribed inline using '\u2022' characters separated by newlines.\", \"Page footer text ('227 Colfax Avenue North, Suite 144, Minneapolis MN 55405' and 'www.imbio.com') and the company logo at the top of the page are outside the table region and were excluded.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "Let me analyze this image. It's a page from a 510(k) Summary document. The page contains a table-like structure with a header row \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" and then rows with left-column labels and right-column content.\n\nThe structure appears to be a two-column table:\n- Header: \"510(k) Summary\" | \"(As required by Section 21 CFR 807.92(c))\"\n- Row 1: \"Summary of Technical Comparisons\" | [long text with Similarities and Differences]\n- Row 2: \"Non-Clinical Testing\" | [long text with bullets]\n\nThe header row is a gray bar spanning the full width: \"510(k) Summary (As required by Section 21 CFR 807.92(c))\". This looks like a single cell spanning both columns, or it could be two cells. Visually it's one continuous gray bar. The text \"510(k) Summary\" is bold, followed by \"(As required by Section 21 CFR 807.92(c))\".\n\nThis is a typical 510(k) summary layout where the table has section labels in the left column and content in the right column. The header \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" spans the whole width.\n\nHow should I transcribe this? The table has:\n- A header row that spans both columns (single cell spanning). \n- Two body rows, each with 2 cells.\n\nGiven the rules, I should transcribe what's printed. The header appears to be a single spanning cell. But the columns structure... Let me think.\n\nOption 1: Treat header as one row with a single cell spanning: columns could be [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\"] and rows would have 2 cells each, causing mismatch. That would trigger rule 8 warnings.\n\nOption 2: Treat the table as 2-column with header cells \"510(k) Summary\" and \"(As required by Section 21 CFR 807.92(c))\". But visually the header is a merged cell spanning both columns. The text \"(As required by Section 21 CFR 807.92(c))\" starts right after \"510(k) Summary\" in the left portion, not aligned to the second column. Actually looking at the image, \"510(k) Summary\" is at the left, and \"(As required by Section 21 CFR 807.92(c))\" follows immediately after it, both within the left portion of the header bar. The header bar spans the full width but the text is all on the left side.\n\nHmm. The most faithful transcription: the header is a single merged cell. I could represent it as columns: [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\"] with header_present: true, and note that body rows have 2 cells while header spans as one cell \u2014 flag mismatch in warnings.\n\nAlternatively, represent the table as two columns with the header text in the first column and empty second column. But that fabricates structure.\n\nActually, let me reconsider. The visible structure: there's a vertical line separating the left label column from the right content column. The header gray bar spans across both columns without a vertical divider visible in the header. So the header is one cell spanning two columns.\n\nI think the cleanest representation faithful to the print:\n- caption: null (no caption printed; the header is part of the table)\n- columns: [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\"] \u2014 as a single spanning header cell\n- rows: each body row has 2 cells\n- header_present: true\n- warnings: note that the header is a single cell spanning both columns while body rows contain 2 cells each.\n\nOr should I make columns have 2 entries? Rule 7 says don't fabricate headers. The header text is printed, so it's not fabrication. But splitting it into two columns would be fabricating alignment. I'll keep it as one column header and flag the mismatch.\n\nNow the content:\n\nRow 1 left cell: \"Summary of Technical Comparisons\"\nRow 1 right cell: \n\"Similarities:\nBoth the predicate device and the Imbio CT Lung Density Analysis Software are software applications that import CT DICOM data files, analyze them, and produce reports with quantitative and graphical results. The functionality of Imbio CT Lung Density Analysis Software is substantially equivalent to the predicate device. Direct quantitative comparisons using the same CT lung scans yielded similar results.\n\nDifferences:\nThe Imbio Lung Density Analysis Software provides a command-line interface, while the predicate device provides a graphic user interface. The Imbio Lung Density Analysis Software provides automated registration of the Inspiration / Expiration image pairs, while this registration is manual (i.e., visually performed by the radiologist) with the predicate device. The predicate device provides an interactive visualization of the reconstructed three-dimensional volume, low-density cluster analysis, and an airway report. These features are not part of the Imbio CT Lung Density Analysis Software. These differences do not affect the efficacy and safety of the Imbio CT Lung Density Analysis Software.\"\n\nRow 2 left cell: \"Non-Clinical Testing\"\nRow 2 right cell:\n\"The following testing was conducted on Imbio CT Lung Density Analysis Software by analyzing CT datasets available upon request from the COPDGene study (www.copdgene.org) and the DIR-Lab (www.dir-lab.com):\n\u2022 Direct predicate comparison for scan processing completion, segmentation, and thresholding. This was done to verify that the software functions according to its specifications and to support substantial equivalence.\n\u2022 Software verification and validation testing for each requirement specification.\n\u2022 Software verification and validation testing for each algorithmic function.\n\u2022 Software verification and validation testing at the unit, integration, and system level\n\nThe following quality assurance measures were applied during software development:\n\u2022 Software Development Life Cycle\n\u2022 Software Risk Assessment.\n\u2022 Risk Assessment of Off-the-Shelf (OTS) Software.\n\u2022 Software Configuration Management and Version Control.\n\u2022 Software issue tracking and resolution.\"\n\nNote the URL \"www.dir-lab.com\" is split across lines as \"www.dir-\" / \"lab.com\" \u2014 hyphenated line break. Should I join it? The printed text shows \"www.dir-lab.com\" split across lines with a hyphen. The hyphen is part of the URL (\"dir-lab\"), so joining as \"www.dir-lab.com\" is correct. Actually the line break shows \"(www.dir-\" then \"lab.com)\". Since \"dir-lab\" contains a hyphen naturally, the joined form is \"www.dir-lab.com\". I'll transcribe it joined and maybe note the line-break join in warnings. Actually, it's ambiguous whether the hyphen is a line-break hyphen or part of the URL. DIR-Lab's website is www.dir-lab.com, so the hyphen is part of the URL. I'll join and flag the normalization in warnings per rule 6-ish.\n\nAlso the footer \"227 Colfax Avenue North, Suite 144, Minneapolis MN 55405\" and \"www.imbio.com\" are outside the table (page footer), so exclude them. The Imbio logo at top is also outside.\n\nShould the cell content preserve line breaks? I'll use \\n within the string to preserve paragraph structure. That's reasonable.\n\nLet me decide on the header representation. I'll go with:\n\ncolumns: [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\"]\n\nWait \u2014 but is the header really one cell? The gray bar spans the full width. There's no vertical divider in the gray bar. So yes, one merged cell. I'll represent columns as a single-element array and flag that body rows have 2 cells (label + content) while the header is a single merged cell spanning both columns.\n\nAlternatively, I could present columns as [\"\", \"\"] \u2014 no, that's bad.\n\nHmm, another approach: treat the table as having 2 columns where the header row is [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\", \"\"] \u2014 but that invents an empty cell. The single-element approach with a warning is more faithful.\n\nActually, let me reconsider whether \"510(k) Summary\" and \"(As required by Section 21 CFR 807.92(c))\" might be two separate cells. Looking at the image: the gray header bar \u2014 \"510(k) Summary\" in bold at left, then \"(As required by Section 21 CFR 807.92(c))\" in regular weight right after. There's no vertical line between them. The vertical column divider below starts below the header. So it's one merged cell. Confirmed.\n\nWarnings to include:\n1. Header row is a single merged cell spanning both columns; body rows have 2 cells each (label column + content column), so cell counts differ from the header.\n2. The URL \"www.dir-lab.com\" was printed split across a line break as \"www.dir-\" / \"lab.com\"; transcribed joined as \"www.dir-lab.com\".\n3. Maybe note that bullets are preserved as \"\u2022\" characters within cell text.\n\nNo acceptance goals, no charts, no unreadable values.\n\nunreadable: false.\n\nLet me write the JSON. Keep text exact. Check punctuation:\n\n\"Similarities:\" \u2014 bold. Then paragraph: \"Both the predicate device and the Imbio CT Lung Density Analysis Software are software applications that import CT DICOM data files, analyze them, and produce reports with quantitative and graphical results. The functionality of Imbio CT Lung Density Analysis Software is substantially equivalent to the predicate device. Direct quantitative comparisons using the same CT lung scans yielded similar results.\"\n\nNote double space after \"results.\" before \"The\" \u2014 I'll normalize to single space; not worth a warning.\n\n\"Differences:\" \u2014 \"The Imbio Lung Density Analysis Software provides a command-line interface, while the predicate device provides a graphic user interface. The Imbio Lung Density Analysis Software provides automated registration of the Inspiration / Expiration image pairs, while this registration is manual (i.e., visually performed by the radiologist) with the predicate device. The predicate device provides an interactive visualization of the reconstructed three-dimensional volume, low-density cluster analysis, and an airway report. These features are not part of the Imbio CT Lung Density Analysis Software. These differences do not affect the efficacy and safety of the Imbio CT Lung Density Analysis Software.\"\n\nNon-Clinical Testing cell:\n\"The following testing was conducted on Imbio CT Lung Density Analysis Software by analyzing CT datasets available upon request from the COPDGene study (www.copdgene.org) and the DIR-Lab (www.dir-lab.com):\n\u2022 Direct predicate comparison for scan processing completion, segmentation, and thresholding. This was done to verify that the software functions according to its specifications and to support substantial equivalence.\n\u2022 Software verification and validation testing for each requirement specification.\n\u2022 Software verification and validation testing for each algorithmic function.\n\u2022 Software verification and validation testing at the unit, integration, and system level\n\nThe following quality assurance measures were applied during software development:\n\u2022 Software Development Life Cycle\n\u2022 Software Risk Assessment.\n\u2022 Risk Assessment of Off-the-Shelf (OTS) Software.\n\u2022 Software Configuration Management and Version Control.\n\u2022 Software issue tracking and resolution.\"\n\nNote: \"system level\" has no trailing period in the image. Correct.\n\nCaption: null.\n\nNow format JSON strictly. Use \\n for newlines within strings.\n\nOne more consideration: should the left-column labels be treated as row headers and thus the \"columns\" only describe content? No \u2014 simplest faithful approach as decided.\n\nFinal JSON:\n\n{\n \"tables\": [\n {\n \"caption\": null,\n \"columns\": [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\"],\n \"rows\": [\n [\"Summary of Technical Comparisons\", \"Similarities:\\nBoth the predicate device ...\"],\n [\"Non-Clinical Testing\", \"The following testing ...\"]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [\n \"The header row is a single merged cell spanning the full table width ('510(k) Summary (As required by Section 21 CFR 807.92(c))'), while each body row contains 2 cells (a left label cell and a right content cell); cell counts therefore differ between the header and body rows.\",\n \"The URL 'www.dir-lab.com' is printed split across a line break as 'www.dir-' / 'lab.com'; it has been transcribed joined as 'www.dir-lab.com'.\",\n \"Bullet list items within the 'Non-Clinical Testing' content cell are transcribed inline using '\u2022' characters and newlines.\"\n ],\n \"unreadable\": false\n}\n\nThat looks good.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 17322,
|
| 23 |
+
"total_tokens": 20620,
|
| 24 |
+
"completion_tokens": 3298,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p7-t0__primary.json
ADDED
|
@@ -0,0 +1,46 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 21.089,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "8d463955fd204a7896f60350b1f39d98",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639191,
|
| 8 |
+
"model": "qwen/qwen3-vl-235b-a22b-instruct",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\n \"tables\": [\n {\n \"caption\": \"510(k) Summary (As required by Section 21 CFR 807.92(c))\",\n \"columns\": [\"Section\", \"Content\"],\n \"rows\": [\n [\n \"Design Validation\",\n \"Design validation was performed using the Imbio CT Lung Density Analysis Software in actual and simulated use settings. The results support substantial equivalence to the predicate device and demonstrate that the Imbio CT Lung Density Analysis Software is safe for its intended use.\"\n ],\n [\n \"Clinical Testing\",\n \"This technology is not new, therefore a clinical study was not considered necessary prior to release. Additionally, there was no clinical testing required to support the medical device as the indications for use is equivalent to the predicate device. The substantial equivalence of the device is supported by the non-clinical testing.\"\n ],\n [\n \"Conclusion:\",\n \"We conclude that the results of testing show the Imbio CT Lung Density Analysis Software to be substantially equivalent to the predicate device. The Imbio CT Lung Density Analysis Software has the same technological characteristics as the predicate device in that it has a similar intended use, same general operating principle, and same technology. The specific details of the predicate device may vary from those of Imbio CT Lung Density Analysis Software, but testing shows that similar results are produced. It has been shown in this 510(k) submission that the differences between the Imbio CT Lung Density Analysis Software and the VIDA PW2 (K0832277) do not raise any questions regarding safety and effectiveness. The Imbio CT Lung Density Analysis Software, as designed and manufactured, is substantially equivalent to, and as safe and effective as, the referenced predicate device.\"\n ]\n ],\n \"header_present\": true\n }\n ],\n \"warnings\": [],\n \"unreadable\": false\n}"
|
| 15 |
+
},
|
| 16 |
+
"finish_reason": "stop"
|
| 17 |
+
}
|
| 18 |
+
],
|
| 19 |
+
"usage": {
|
| 20 |
+
"prompt_tokens": 3161,
|
| 21 |
+
"completion_tokens": 389,
|
| 22 |
+
"total_tokens": 3550,
|
| 23 |
+
"prompt_tokens_details": {
|
| 24 |
+
"audio_tokens": 0,
|
| 25 |
+
"cached_tokens": 0,
|
| 26 |
+
"cache_write_tokens": 0,
|
| 27 |
+
"cache_creation_input_tokens": 0,
|
| 28 |
+
"cache_read_input_tokens": 0,
|
| 29 |
+
"text_tokens": 663,
|
| 30 |
+
"image_tokens": 2498,
|
| 31 |
+
"video_tokens": 0
|
| 32 |
+
},
|
| 33 |
+
"completion_tokens_details": {
|
| 34 |
+
"audio_tokens": 0,
|
| 35 |
+
"reasoning_tokens": 0,
|
| 36 |
+
"accepted_prediction_tokens": 0,
|
| 37 |
+
"rejected_prediction_tokens": 0,
|
| 38 |
+
"text_tokens": 389,
|
| 39 |
+
"image_tokens": 0,
|
| 40 |
+
"video_tokens": 0
|
| 41 |
+
}
|
| 42 |
+
},
|
| 43 |
+
"system_fingerprint": ""
|
| 44 |
+
},
|
| 45 |
+
"error": null
|
| 46 |
+
}
|
data/vlm_run/raw/pass_a/K141069-p7-t0__secondpass.json
ADDED
|
@@ -0,0 +1,31 @@
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 |
+
{
|
| 2 |
+
"latency_s": 30.085,
|
| 3 |
+
"status_code": 200,
|
| 4 |
+
"body": {
|
| 5 |
+
"id": "Root=1-6a6eb119-1d4ae81f11fb419939b09d86-chatcmpl-6eb3ab3",
|
| 6 |
+
"object": "chat.completion",
|
| 7 |
+
"created": 1785639196,
|
| 8 |
+
"model": "accounts/fireworks/models/kimi-k3",
|
| 9 |
+
"choices": [
|
| 10 |
+
{
|
| 11 |
+
"index": 0,
|
| 12 |
+
"message": {
|
| 13 |
+
"role": "assistant",
|
| 14 |
+
"content": "{\"tables\": [{\"caption\": \"510(k) Summary (As required by Section 21 CFR 807.92(c))\", \"columns\": [], \"rows\": [[\"Design Validation\", \"Design validation was performed using the Imbio CT Lung Density Analysis Software in actual and simulated use settings. The results support substantial equivalence to the predicate device and demonstrate that the Imbio CT Lung Density Analysis Software is safe for its intended use.\"], [\"Clinical Testing\", \"This technology is not new, therefore a clinical study was not considered necessary prior to release. Additionally, there was no clinical testing required to support the medical device as the indications for use is equivalent to the predicate device. The substantial equivalence of the device is supported by the non-clinical testing.\"], [\"Conclusion:\", \"We conclude that the results of testing show the Imbio CT Lung Density Analysis Software to be substantially equivalent to the predicate device.\\n\\nThe Imbio CT Lung Density Analysis Software has the same technological characteristics as the predicate device in that it has a similar intended use, same general operating principle, and same technology. The specific details of the predicate device may vary from those of Imbio CT Lung Density Analysis Software, but testing shows that similar results are produced.\\n\\nIt has been shown in this 510(k) submission that the differences between the Imbio CT Lung Density Analysis Software and the VIDA PW2 (K0832277) do not raise any questions regarding safety and effectiveness. The Imbio CT Lung Density Analysis Software, as designed and manufactured, is substantially equivalent to, and as safe and effective as, the referenced predicate device.\"]], \"header_present\": false}], \"warnings\": [\"The top row '510(k) Summary (As required by Section 21 CFR 807.92(c))' is a title banner spanning both columns, not a printed column header; it was captured as the caption and header_present was set to false. No column headers are printed in this crop.\", \"The 'Conclusion:' row's right cell contains multiple paragraphs; paragraph breaks were preserved as newline characters within the single cell string.\"], \"unreadable\": false}",
|
| 15 |
+
"reasoning_content": "Let me analyze the image. It's a 510(k) Summary table with a header row \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" which spans the full width. Then there are rows with two columns: a label column (Design Validation, Clinical Testing, Conclusion:) and a content column.\n\nThe header row appears to be a single cell spanning both columns: \"510(k) Summary (As required by Section 21 CFR 807.92(c))\". This is more of a title/caption row than a column header. But it is printed in the table as a header-like row.\n\nHow to structure this? The table has two columns visually (label and description). The header row spans both columns. There's no printed column header like \"Section\" / \"Description\". \n\nOptions:\n1. Treat \"510(k) Summary (As required by Section 21 CFR 807.92(c))\" as caption, and header_present: false, columns: [].\n2. Treat it as a header row with one column.\n\nThe header row is a title banner, not column headers. Per rule 7, don't fabricate column names. The visible \"header\" is a title spanning the table. I think the best approach: caption = \"510(k) Summary (As required by Section 21 CFR 807.92(c))\", header_present = false, columns = [], rows = the three rows each with 2 cells.\n\nActually, could also set columns to [\"510(k) Summary (As required by Section 21 CFR 807.92(c))\"] but that would misrepresent. The banner spans both columns, so it's a caption/title. I'll use caption.\n\nRows:\n1. [\"Design Validation\", \"Design validation was performed using the Imbio CT Lung Density Analysis Software in actual and simulated use settings. The results support substantial equivalence to the predicate device and demonstrate that the Imbio CT Lung Density Analysis Software is safe for its intended use.\"]\n2. [\"Clinical Testing\", \"This technology is not new, therefore a clinical study was not considered necessary prior to release. Additionally, there was no clinical testing required to support the medical device as the indications for use is equivalent to the predicate device. The substantial equivalence of the device is supported by the non-clinical testing.\"]\n3. [\"Conclusion:\", \"We conclude that the results of testing show the Imbio CT Lung Density Analysis Software to be substantially equivalent to the predicate device.\\n\\nThe Imbio CT Lung Density Analysis Software has the same technological characteristics as the predicate device in that it has a similar intended use, same general operating principle, and same technology. The specific details of the predicate device may vary from those of Imbio CT Lung Density Analysis Software, but testing shows that similar results are produced.\\n\\nIt has been shown in this 510(k) submission that the differences between the Imbio CT Lung Density Analysis Software and the VIDA PW2 (K0832277) do not raise any questions regarding safety and effectiveness. The Imbio CT Lung Density Analysis Software, as designed and manufactured, is substantially equivalent to, and as safe and effective as, the referenced predicate device.\"]\n\nShould I join paragraphs with newlines or spaces? I'll use \"\\n\\n\" to preserve paragraph breaks, or just spaces. Either is fine; I'll use \"\\n\\n\".\n\nWarnings: header row spans both columns as a title banner; treated as caption. No column headers printed.\n\nunreadable: false.",
|
| 16 |
+
"tools": null
|
| 17 |
+
},
|
| 18 |
+
"finish_reason": "stop"
|
| 19 |
+
}
|
| 20 |
+
],
|
| 21 |
+
"usage": {
|
| 22 |
+
"prompt_tokens": 15236,
|
| 23 |
+
"total_tokens": 16401,
|
| 24 |
+
"completion_tokens": 1165,
|
| 25 |
+
"prompt_tokens_details": {
|
| 26 |
+
"cached_tokens": 0
|
| 27 |
+
}
|
| 28 |
+
}
|
| 29 |
+
},
|
| 30 |
+
"error": null
|
| 31 |
+
}
|