dnamodel commited on
Commit
e0ec008
·
verified ·
1 Parent(s): 123a632

Use the public BREST-AI model name

Browse files
Files changed (2) hide show
  1. README.md +2 -2
  2. SHA256SUMS +1 -1
README.md CHANGED
@@ -13,7 +13,7 @@ tags:
13
 
14
  # BREST-AI: three-year breast cancer risk from screening mammograms
15
 
16
- This release provides the **published BREST-AI v1, 16-bit, four-view model** developed at the University of Warwick with NHS and academic collaborators. It estimates an examination-level three-year risk score from a screening mammogram. The model uses a ResNeXt-50 encoder and attentional feature fusion.
17
 
18
  **Paper:** Wei J, Zhou X, Santeramo R, et al. *BREST-AI: Three-year breast cancer risk prediction from screening mammograms*. npj Breast Cancer (2026). [doi:10.1038/s41523-026-01069-x](https://doi.org/10.1038/s41523-026-01069-x).
19
 
@@ -41,7 +41,7 @@ The repository supplies the model definition and checks the downloaded weights a
41
 
42
  Use the repository's documented DICOM preprocessing to produce breast-aligned 2048 × 2048 grayscale 16-bit PNGs. Select `paper-hologic` for 16-bit rendering with Lanczos resizing, or `paper-siemens` to reproduce the original Siemens route of 8-bit rendering expanded to uint16 followed by NumPy bilinear resizing. Both profiles use a fixed background seed of 42. Inference divides pixels by 65535, repeats the grayscale channel three times, resizes to 1792 × 1792 using the original Kornia bilinear antialiased resize, and normalises with mean 0.0856 and standard deviation 0.1687 per channel. Right-breast flipping belongs to DICOM preprocessing; inference does not flip the prepared images again.
43
 
44
- Each examination requires one image for each of **left CC, right CC, left MLO and right MLO**, in that network order. The CSV supplies `ClientID`, `path`, `ViewPosition` and `ImageLaterality`; `EpisodeID` distinguishes repeat examinations. The loader validates and orders these views. Outcome labels are optional for prediction. For an original v1 evaluation CSV whose rows are already ordered, `--preserve_row_order` reproduces the original loader without sorting historical view tags.
45
 
46
  The output is the sigmoid of one examination-level risk logit. Population calibration is required before interpreting it as an absolute three-year probability. Its value is not the probability that an MRI will detect a cancer immediately.
47
 
 
13
 
14
  # BREST-AI: three-year breast cancer risk from screening mammograms
15
 
16
+ This release provides the **BREST-AI 16-bit, four-view model** developed at the University of Warwick with NHS and academic collaborators. It estimates an examination-level three-year risk score from a screening mammogram. The model uses a ResNeXt-50 encoder and attentional feature fusion.
17
 
18
  **Paper:** Wei J, Zhou X, Santeramo R, et al. *BREST-AI: Three-year breast cancer risk prediction from screening mammograms*. npj Breast Cancer (2026). [doi:10.1038/s41523-026-01069-x](https://doi.org/10.1038/s41523-026-01069-x).
19
 
 
41
 
42
  Use the repository's documented DICOM preprocessing to produce breast-aligned 2048 × 2048 grayscale 16-bit PNGs. Select `paper-hologic` for 16-bit rendering with Lanczos resizing, or `paper-siemens` to reproduce the original Siemens route of 8-bit rendering expanded to uint16 followed by NumPy bilinear resizing. Both profiles use a fixed background seed of 42. Inference divides pixels by 65535, repeats the grayscale channel three times, resizes to 1792 × 1792 using the original Kornia bilinear antialiased resize, and normalises with mean 0.0856 and standard deviation 0.1687 per channel. Right-breast flipping belongs to DICOM preprocessing; inference does not flip the prepared images again.
43
 
44
+ Each examination requires one image for each of **left CC, right CC, left MLO and right MLO**, in that network order. The CSV supplies `ClientID`, `path`, `ViewPosition` and `ImageLaterality`; `EpisodeID` distinguishes repeat examinations. The loader validates and orders these views. Outcome labels are optional for prediction. For an original evaluation CSV whose rows are already ordered, `--preserve_row_order` reproduces the original loader without sorting historical view tags.
45
 
46
  The output is the sigmoid of one examination-level risk logit. Population calibration is required before interpreting it as an absolute three-year probability. Its value is not the probability that an MRI will detect a cancer immediately.
47
 
SHA256SUMS CHANGED
@@ -1,5 +1,5 @@
1
  9bc0c7770ba62ac18dc3da1609b581048f166a483eec048bb9b839c083d7b04c LICENSE
2
- 18b46ae9b97bedeb587cea45281bf03d34e61b555f71c2c99ff93f4c7851c022 README.md
3
  766ab4f327e0a4c908eb4bdce743718b52fbb68b19e061d030ebd831182435eb brest-ai-v1.safetensors
4
  9a015953a3cbfea60eb5ab4a09568cc1aed36d5c35f162b428153a704f0c87ee config.json
5
  69557eaa0c9a681ee58b8ef66d68a684274a64faec0cc0fa63dba756e01d2c4d weights_manifest.json
 
1
  9bc0c7770ba62ac18dc3da1609b581048f166a483eec048bb9b839c083d7b04c LICENSE
2
+ 50a9b8df3eb859ee37335c7b40ae655208cfa3de338664d1892fb87146565ac6 README.md
3
  766ab4f327e0a4c908eb4bdce743718b52fbb68b19e061d030ebd831182435eb brest-ai-v1.safetensors
4
  9a015953a3cbfea60eb5ab4a09568cc1aed36d5c35f162b428153a704f0c87ee config.json
5
  69557eaa0c9a681ee58b8ef66d68a684274a64faec0cc0fa63dba756e01d2c4d weights_manifest.json