1baf215 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 | """Randomized, constrained physical systems with reproducible common-noise snapshots.
Controls are power (kW) or valve/pump fractions, elapsed time is minutes.
The thermal integrator uses <=1-minute steps; tank and charge balance are exact.
"""
import copy
import numpy as np
from tfm.data.schema import FIELD_INDEX, FIELD_SPECS, NUM_FIELDS, SCHEMAS, role_fields
class PhysicalSimulator:
def __init__(self, family, seed):
if family not in SCHEMAS:
raise ValueError(f"Unknown family {family!r}; choose {tuple(SCHEMAS)}")
self.family = family
self.seed = int(seed)
self.rng = np.random.default_rng(seed)
self.schema = list(SCHEMAS[family])
r = self.rng
if family == "thermal":
two_node = bool(r.random() < 0.65)
self.parameters = {
"two_node": two_node,
"air_capacity": r.uniform(0.5, 3),
"mass_capacity": r.uniform(3, 20),
"envelope_conductance": r.uniform(0.08, 0.4),
"mass_conductance": r.uniform(0.2, 1.2),
"hvac_efficiency": r.uniform(0.8, 1.1),
"process_noise_std": r.uniform(0.005, 0.025),
"max_heating_power": r.uniform(4, 15),
"max_cooling_power": r.uniform(3, 14),
}
if not two_node:
self.schema.remove("mass_temp")
self.state = np.array([r.uniform(18, 26)] * (2 if two_node else 1) + [0.0])
elif family == "tank":
capacity = r.uniform(2, 20)
self.parameters = {
"capacity": capacity,
"leakage_rate": r.uniform(0.002, 0.025),
"inlet_efficiency": r.uniform(0.9, 1),
"process_noise_std": r.uniform(0.001, 0.008),
}
self.parameters.update(
max_pump_flow=r.uniform(2, 8),
valve_coefficient=r.uniform(0.4, 1.2),
heat_loss=r.uniform(0.005, 0.03),
pressure_head=r.uniform(60, 160),
)
self.state = np.array([r.uniform(0.2, 0.8) * capacity, r.uniform(12, 24), 0.0, 0.0])
else:
self.parameters = {
"capacity_kwh": r.uniform(5, 60),
"charge_efficiency": r.uniform(0.90, 0.99),
"discharge_efficiency": r.uniform(0.90, 0.99),
"self_discharge": r.uniform(0.0001, 0.001),
"thermal_capacity": r.uniform(0.1, 0.7),
"thermal_conductance": r.uniform(0.03, 0.15),
"resistance_loss": r.uniform(0.015, 0.06),
"process_noise_std": r.uniform(0.0001, 0.0005),
}
self.parameters.update(
nominal_voltage=r.uniform(24, 52), internal_resistance=r.uniform(0.01, 0.08)
)
soc = r.uniform(0.2, 0.8)
self.state = np.array(
[soc, r.uniform(18, 30), self.parameters["nominal_voltage"] * (0.9 + 0.2 * soc)]
)
self.step_count = 0
def _compact(self, values, role):
names = role_fields(self.schema, role)
if isinstance(values, dict):
if set(values) != set(names):
raise ValueError(f"{role} dictionary must contain exactly {names}")
a = np.array([values[n] for n in names], dtype=float)
else:
a = np.asarray(values, dtype=float)
if a.shape == (NUM_FIELDS,):
a = a[[FIELD_INDEX[n] for n in names]]
if a.shape != (len(names),) or not np.isfinite(a).all():
raise ValueError(f"{role} must be finite compact {names} or canonical vector")
if role == "action":
bounds = [
(FIELD_SPECS[FIELD_INDEX[n]].minimum, FIELD_SPECS[FIELD_INDEX[n]].maximum) for n in names
]
if any(not low <= value <= high for value, (low, high) in zip(a, bounds)):
raise ValueError(f"Control outside public actuator bounds: {names}")
return a
def step(self, action, exogenous, dt_minutes=15):
if not np.isfinite(dt_minutes) or not 0 < dt_minutes <= 1440:
raise ValueError("dt_minutes must be in (0,1440]")
a, e = self._compact(action, "action"), self._compact(exogenous, "exogenous")
p = self.parameters
dt = dt_minutes / 60
# A fixed draw per state/step allows counterfactual branches to share disturbances.
noise = self.rng.normal(size=len(self.state)) * p["process_noise_std"] * np.sqrt(dt)
if self.family == "thermal":
power = np.clip(a[0], -p["max_cooling_power"], p["max_heating_power"])
outside, solar, occupants = e
outside, solar, occupants = (
np.clip(outside, -30, 60),
np.clip(solar, 0, 5),
np.clip(occupants, 0, 3),
)
n = int(np.ceil(dt_minutes))
h = dt / n
for _ in range(n):
air = self.state[0]
flux = (
p["envelope_conductance"] * (outside - air)
+ p["hvac_efficiency"] * power
+ solar
+ occupants
)
if p["two_node"]:
mass_flux = p["mass_conductance"] * (self.state[1] - air)
self.state[:2] += h * np.array(
[(flux + mass_flux) / p["air_capacity"], -mass_flux / p["mass_capacity"]]
)
else:
self.state[0] += h * flux / p["air_capacity"]
self.state[:-1] = np.clip(self.state[:-1] + noise[:-1], -30, 70)
self.state[-1] += abs(power) * dt
elif self.family == "tank":
valve, pump = np.clip(a, 0, 1)
demand, inlet_temp = np.clip(e[0], 0, 10), np.clip(e[1], -5, 60)
incoming = pump * p["max_pump_flow"] * p["inlet_efficiency"]
outgoing = min(demand * valve * p["valve_coefficient"], self.state[0] / dt + incoming)
rate = incoming - outgoing
decay = np.exp(-p["leakage_rate"] * dt)
level = self.state[0] * decay + rate * (1 - decay) / p["leakage_rate"]
old_level = self.state[0]
self.state[0] = np.clip(level + noise[0], 0, p["capacity"])
mixing = 1 - np.exp(-incoming * dt / max(old_level, 0.05))
self.state[1] = np.clip(
self.state[1]
+ mixing * (inlet_temp - self.state[1])
+ p["heat_loss"] * dt * (20 - self.state[1])
+ noise[1],
-5,
80,
)
self.state[2] = max(0.0, outgoing)
self.state[3] = np.clip(
p["pressure_head"] * pump**2 + 9.81 * self.state[0] / p["capacity"], 0, 300
)
else:
power = np.clip(a[0], -20, 20)
ambient = np.clip(e[0], -30, 60)
thermal_derating = np.clip(1 - 0.002 * abs(self.state[1] - 25), 0.75, 1.0)
resistance_factor = (
1 + 0.018 * max(0.0, 25 - self.state[1]) + 0.006 * max(0.0, self.state[1] - 40)
)
resistance_derating = 1 + p["resistance_loss"] * resistance_factor
charge_efficiency = p["charge_efficiency"] * thermal_derating / resistance_derating
discharge_efficiency = p["discharge_efficiency"] * thermal_derating / resistance_derating
charge = power * charge_efficiency if power >= 0 else power / discharge_efficiency
soc = np.clip(
self.state[0] * (1 - p["self_discharge"] * dt) + charge * dt / p["capacity_kwh"] + noise[0],
0,
1,
)
# At charge boundaries only accepted energy produces resistive heating.
soc_without_charge = self.state[0] * (1 - p["self_discharge"] * dt)
stored_change = max(0.0, abs(soc - soc_without_charge) - abs(noise[0])) * p["capacity_kwh"] / dt
accepted = min(
abs(power),
stored_change / charge_efficiency if power >= 0 else stored_change * discharge_efficiency,
)
decay = np.exp(-p["thermal_conductance"] * dt / p["thermal_capacity"])
conversion_loss = (
accepted * (1 - charge_efficiency)
if power >= 0
else accepted * (1 / discharge_efficiency - 1)
)
heat = conversion_loss # all electrical conversion loss becomes heat; no double counting
equilibrium = ambient + heat / p["thermal_conductance"]
temp = equilibrium + (self.state[1] - equilibrium) * decay + noise[1]
voltage = (
p["nominal_voltage"] * (0.9 + 0.2 * soc)
+ power * 1000 / p["nominal_voltage"] * p["internal_resistance"] * resistance_factor
)
self.state = np.array([soc, np.clip(temp, -30, 80), np.clip(voltage, 10, 70)])
self.step_count += 1
return self.state.copy()
def snapshot(self):
return {
"version": 1,
"family": self.family,
"seed": self.seed,
"parameters": copy.deepcopy(self.parameters),
"schema": list(self.schema),
"state": self.state.copy(),
"rng_state": copy.deepcopy(self.rng.bit_generator.state),
"step_count": self.step_count,
}
def restore(self, snapshot):
if snapshot.get("version") != 1:
raise ValueError("Unsupported simulator snapshot version")
if snapshot["family"] != self.family or snapshot["schema"] != self.schema:
raise ValueError("Snapshot belongs to a different simulator schema")
state = np.asarray(snapshot["state"], dtype=float)
if state.shape != self.state.shape or not np.isfinite(state).all():
raise ValueError("Snapshot state must match finite simulator state shape")
restored_rng = np.random.default_rng()
restored_rng.bit_generator.state = copy.deepcopy(snapshot["rng_state"])
self.parameters = copy.deepcopy(snapshot["parameters"])
self.state = state.copy()
self.rng = restored_rng
self.seed = snapshot["seed"]
self.step_count = snapshot["step_count"]
def make_simulator(family, seed):
return PhysicalSimulator(family, seed)
def counterfactual_rollout(simulator, snapshot, actions, exogenous, dt_minutes=15):
"""Replay a branch from a snapshot; preserve caller state and noise stream."""
if len(actions) != len(exogenous):
raise ValueError("Actions and exogenous must have identical lengths")
original = simulator.snapshot()
try:
simulator.restore(snapshot)
states = [simulator.state.copy()]
states.extend(simulator.step(a, e, dt_minutes) for a, e in zip(actions, exogenous))
return np.asarray(states)
finally:
simulator.restore(original)
|