new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 17

EHRSHOT: An EHR Benchmark for Few-Shot Evaluation of Foundation Models

While the general machine learning (ML) community has benefited from public datasets, tasks, and models, the progress of ML in healthcare has been hampered by a lack of such shared assets. The success of foundation models creates new challenges for healthcare ML by requiring access to shared pretrained models to validate performance benefits. We help address these challenges through three contributions. First, we publish a new dataset, EHRSHOT, which contains deidentified structured data from the electronic health records (EHRs) of 6,739 patients from Stanford Medicine. Unlike MIMIC-III/IV and other popular EHR datasets, EHRSHOT is longitudinal and not restricted to ICU/ED patients. Second, we publish the weights of CLMBR-T-base, a 141M parameter clinical foundation model pretrained on the structured EHR data of 2.57M patients. We are one of the first to fully release such a model for coded EHR data; in contrast, most prior models released for clinical data (e.g. GatorTron, ClinicalBERT) only work with unstructured text and cannot process the rich, structured data within an EHR. We provide an end-to-end pipeline for the community to validate and build upon its performance. Third, we define 15 few-shot clinical prediction tasks, enabling evaluation of foundation models on benefits such as sample efficiency and task adaptation. Our model and dataset are available via a research data use agreement from the Stanford AIMI Center. Code to reproduce our results are available at our Github repo: https://github.com/som-shahlab/ehrshot-benchmark

  • 5 authors
·
Jul 5, 2023

Health system learning achieves generalist neuroimaging models

Frontier artificial intelligence (AI) models, such as OpenAI's GPT-5 and Meta's DINOv3, have advanced rapidly through training on internet-scale public data, yet such systems lack access to private clinical data. Neuroimaging, in particular, is underrepresented in the public domain due to identifiable facial features within MRI and CT scans, fundamentally restricting model performance in clinical medicine. Here, we show that frontier models underperform on neuroimaging tasks and that learning directly from uncurated data generated during routine clinical care at health systems, a paradigm we call health system learning, yields high-performance, generalist neuroimaging models. We introduce NeuroVFM, a visual foundation model trained on 5.24 million clinical MRI and CT volumes using a scalable volumetric joint-embedding predictive architecture. NeuroVFM learns comprehensive representations of brain anatomy and pathology, achieving state-of-the-art performance across multiple clinical tasks, including radiologic diagnosis and report generation. The model exhibits emergent neuroanatomic understanding and interpretable visual grounding of diagnostic findings. When paired with open-source language models through lightweight visual instruction tuning, NeuroVFM generates radiology reports that surpass frontier models in accuracy, clinical triage, and expert preference. Through clinically grounded visual understanding, NeuroVFM reduces hallucinated findings and critical errors, offering safer clinical decision support. These results establish health system learning as a paradigm for building generalist medical AI and provide a scalable framework for clinical foundation models.

The Patient is not a Moving Document: A World Model Training Paradigm for Longitudinal EHR

Large language models (LLMs) trained with next-word-prediction have achieved success as clinical foundation models. Representations from these language backbones yield strong linear probe performance across biomedical tasks, suggesting that patient semantics emerge from next-token prediction at scale. However, this paradigm treats patients as a document to be summarized rather than a dynamical system to be simulated; a patient's trajectory emerges from their state evolving under interventions and time, requiring models that simulate dynamics rather than predict tokens. To address this, we introduce SMB-Structure, a world model for structured EHR that grounds a joint-embedding prediction architecture (JEPA) with next-token prediction (SFT). SFT grounds our model to reconstruct future patient states in token space, while JEPA predicts those futures in latent space from the initial patient representation alone, forcing trajectory dynamics to be encoded before the next state is observed. We validate across two large-scale cohorts: Memorial Sloan Kettering (23,319 oncology patients; 323,000+ patient-years) and INSPECT (19,402 pulmonary embolism patients). Using a linear probe evaluated at multiple points along the disease trajectory, we demonstrate that our training paradigm learns embeddings that capture disease dynamics not recoverable by autoregressive baselines, enabling SMB-Structure to achieve competitive performance on complex tasks characterized by high patient heterogeneity. Model weights are available at https://huggingface.co/standardmodelbio/SMB-v1-1.7B-Structure.

  • 8 authors
·
Jan 29

Panacea: A foundation model for clinical trial search, summarization, design, and recruitment

Clinical trials are fundamental in developing new drugs, medical devices, and treatments. However, they are often time-consuming and have low success rates. Although there have been initial attempts to create large language models (LLMs) for clinical trial design and patient-trial matching, these models remain task-specific and not adaptable to diverse clinical trial tasks. To address this challenge, we propose a clinical trial foundation model named Panacea, designed to handle multiple tasks, including trial search, trial summarization, trial design, and patient-trial matching. We also assemble a large-scale dataset, named TrialAlign, of 793,279 trial documents and 1,113,207 trial-related scientific papers, to infuse clinical knowledge into the model by pre-training. We further curate TrialInstruct, which has 200,866 of instruction data for fine-tuning. These resources enable Panacea to be widely applicable for a range of clinical trial tasks based on user requirements. We evaluated Panacea on a new benchmark, named TrialPanorama, which covers eight clinical trial tasks. Our method performed the best on seven of the eight tasks compared to six cutting-edge generic or medicine-specific LLMs. Specifically, Panacea showed great potential to collaborate with human experts in crafting the design of eligibility criteria, study arms, and outcome measures, in multi-round conversations. In addition, Panacea achieved 14.42% improvement in patient-trial matching, 41.78% to 52.02% improvement in trial search, and consistently ranked at the top for five aspects of trial summarization. Our approach demonstrates the effectiveness of Panacea in clinical trials and establishes a comprehensive resource, including training data, model, and benchmark, for developing clinical trial foundation models, paving the path for AI-based clinical trial development.

  • 5 authors
·
Jun 25, 2024

Generalist Foundation Models Are Not Clinical Enough for Hospital Operations

Hospitals and healthcare systems rely on operational decisions that determine patient flow, cost, and quality of care. Despite strong performance on medical knowledge and conversational benchmarks, foundation models trained on general text may lack the specialized knowledge required for these operational decisions. We introduce Lang1, a family of models (100M-7B parameters) pretrained on a specialized corpus blending 80B clinical tokens from NYU Langone Health's EHRs and 627B tokens from the internet. To rigorously evaluate Lang1 in real-world settings, we developed the REalistic Medical Evaluation (ReMedE), a benchmark derived from 668,331 EHR notes that evaluates five critical tasks: 30-day readmission prediction, 30-day mortality prediction, length of stay, comorbidity coding, and predicting insurance claims denial. In zero-shot settings, both general-purpose and specialized models underperform on four of five tasks (36.6%-71.7% AUROC), with mortality prediction being an exception. After finetuning, Lang1-1B outperforms finetuned generalist models up to 70x larger and zero-shot models up to 671x larger, improving AUROC by 3.64%-6.75% and 1.66%-23.66% respectively. We also observed cross-task scaling with joint finetuning on multiple tasks leading to improvement on other tasks. Lang1-1B effectively transfers to out-of-distribution settings, including other clinical tasks and an external health system. Our findings suggest that predictive capabilities for hospital operations require explicit supervised finetuning, and that this finetuning process is made more efficient by in-domain pretraining on EHR. Our findings support the emerging view that specialized LLMs can compete with generalist models in specialized tasks, and show that effective healthcare systems AI requires the combination of in-domain pretraining, supervised finetuning, and real-world evaluation beyond proxy benchmarks.

newyorkuniversity New York University
·
Nov 17, 2025 3

Self-supervision drives representational convergence in medical foundation models more than clinical supervision

Medical image encoders from different groups are increasingly treated as interchangeable, on the assumption that scale and clinical supervision concentrate their representations onto a shared structure. Whether this convergence is real, what produces it, and whether it is clinically usable are untested, and the similarity measures behind such claims are fragile. We present a controlled dissection across 18 image and 7 text encoders, all open-weight and run locally, spanning 7M to 27B parameters and five imaging modalities, including 650,982 chest radiographs from six datasets. To isolate cause, we train encoders that vary only the objective under fixed data, architecture, and scale, and reproduce the effect in a synthetic model. Convergence is modest but above a random floor, driven by the self-supervised objective, not clinical supervision: matched self-supervised encoders aligned most (40.4% on chest radiography), with label-supervised (21.1%) and image-text (3.3%) far lower, and did not grow with size (Spearman 0.302, p=0.223) or capability. It is within-modality, does not reach clinical language, and does not reproduce how radiologists judge case similarity. Yet a linear classifier transfers across encoders and to five held-out hospitals, retaining about 85% of within-encoder performance. Convergence in medical imaging is therefore set by the pretraining objective, not inherited from scale or clinical supervision. Interoperability is accordingly something to design for through that objective, and to validate where the shared geometry is weakest, across patient subgroups and against clinical judgment.

  • 7 authors
·
Jul 21

Towards Brain MRI Foundation Models for the Clinic: Findings from the FOMO25 Challenge

Clinical deployment of automated brain MRI analysis faces a fundamental challenge: clinical data is heterogeneous and noisy, and high-quality labels are prohibitively costly to obtain. Self-supervised learning (SSL) can address this by leveraging the vast amounts of unlabeled data produced in clinical workflows to train robust foundation models that adapt out-of-domain with minimal supervision. However, the development of foundation models for brain MRI has been limited by small pretraining datasets and in-domain benchmarking focused on high-quality, research-grade data. To address this gap, we organized the FOMO25 challenge as a satellite event at MICCAI 2025. FOMO25 provided participants with a large pretraining dataset, FOMO60K, and evaluated models on data sourced directly from clinical workflows in few-shot and out-of-domain settings. Tasks covered infarct classification, meningioma segmentation, and brain age regression, and considered both models trained on FOMO60K (method track) and any data (open track). Nineteen foundation models from sixteen teams were evaluated using a standardized containerized pipeline. Results show that (a) self-supervised pretraining improves generalization on clinical data under domain shift, with the strongest models trained out-of-domain surpassing supervised baselines trained in-domain. (b) No single pretraining objective benefits all tasks: MAE favors segmentation, hybrid reconstruction-contrastive objectives favor classification, and (c) strong performance was achieved by small pretrained models, and improvements from scaling model size and training duration did not yield reliable benefits.

A Vision-Language Foundation Model for Zero-shot Clinical Collaboration and Automated Concept Discovery in Dermatology

Medical foundation models have shown promise in controlled benchmarks, yet widespread deployment remains hindered by reliance on task-specific fine-tuning. Here, we introduce DermFM-Zero, a dermatology vision-language foundation model trained via masked latent modelling and contrastive learning on over 4 million multimodal data points. We evaluated DermFM-Zero across 20 benchmarks spanning zero-shot diagnosis and multimodal retrieval, achieving state-of-the-art performance without task-specific adaptation. We further evaluated its zero-shot capabilities in three multinational reader studies involving over 1,100 clinicians. In primary care settings, AI assistance enabled general practitioners to nearly double their differential diagnostic accuracy across 98 skin conditions. In specialist settings, the model significantly outperformed board-certified dermatologists in multimodal skin cancer assessment. In collaborative workflows, AI assistance enabled non-experts to surpass unassisted experts while improving management appropriateness. Finally, we show that DermFM-Zero's latent representations are interpretable: sparse autoencoders unsupervisedly disentangle clinically meaningful concepts that outperform predefined-vocabulary approaches and enable targeted suppression of artifact-induced biases, enhancing robustness without retraining. These findings demonstrate that a foundation model can provide effective, safe, and transparent zero-shot clinical decision support.

  • 31 authors
·
Feb 10

Context Clues: Evaluating Long Context Models for Clinical Prediction Tasks on EHRs

Foundation Models (FMs) trained on Electronic Health Records (EHRs) have achieved state-of-the-art results on numerous clinical prediction tasks. However, most existing EHR FMs have context windows of <1k tokens. This prevents them from modeling full patient EHRs which can exceed 10k's of events. Recent advancements in subquadratic long-context architectures (e.g., Mamba) offer a promising solution. However, their application to EHR data has not been well-studied. We address this gap by presenting the first systematic evaluation of the effect of context length on modeling EHR data. We find that longer context models improve predictive performance -- our Mamba-based model surpasses the prior state-of-the-art on 9/14 tasks on the EHRSHOT prediction benchmark. For clinical applications, however, model performance alone is insufficient -- robustness to the unique properties of EHR is crucial. Thus, we also evaluate models across three previously underexplored properties of EHR data: (1) the prevalence of "copy-forwarded" diagnoses which creates artificial repetition of tokens within EHR sequences; (2) the irregular time intervals between EHR events which can lead to a wide range of timespans within a context window; and (3) the natural increase in disease complexity over time which makes later tokens in the EHR harder to predict than earlier ones. Stratifying our EHRSHOT results, we find that higher levels of each property correlate negatively with model performance, but that longer context models are more robust to more extreme levels of these properties. Our work highlights the potential for using long-context architectures to model EHR data, and offers a case study for identifying new challenges in modeling sequential data motivated by domains outside of natural language. We release our models and code at: https://github.com/som-shahlab/long_context_clues

  • 8 authors
·
Dec 9, 2024

Current Pathology Foundation Models are unrobust to Medical Center Differences

Pathology Foundation Models (FMs) hold great promise for healthcare. Before they can be used in clinical practice, it is essential to ensure they are robust to variations between medical centers. We measure whether pathology FMs focus on biological features like tissue and cancer type, or on the well known confounding medical center signatures introduced by staining procedure and other differences. We introduce the Robustness Index. This novel robustness metric reflects to what degree biological features dominate confounding features. Ten current publicly available pathology FMs are evaluated. We find that all current pathology foundation models evaluated represent the medical center to a strong degree. Significant differences in the robustness index are observed. Only one model so far has a robustness index greater than one, meaning biological features dominate confounding features, but only slightly. A quantitative approach to measure the influence of medical center differences on FM-based prediction performance is described. We analyze the impact of unrobustness on classification performance of downstream models, and find that cancer-type classification errors are not random, but specifically attributable to same-center confounders: images of other classes from the same medical center. We visualize FM embedding spaces, and find these are more strongly organized by medical centers than by biological factors. As a consequence, the medical center of origin is predicted more accurately than the tissue source and cancer type. The robustness index introduced here is provided with the aim of advancing progress towards clinical adoption of robust and reliable pathology FMs.

  • 3 authors
·
Jan 29, 2025 2

Towards Robust Foundation Models for Digital Pathology

Biomedical Foundation Models (FMs) are rapidly transforming AI-enabled healthcare research and entering clinical validation. However, their susceptibility to learning non-biological technical features -- including variations in surgical/endoscopic techniques, laboratory procedures, and scanner hardware -- poses risks for clinical deployment. We present the first systematic investigation of pathology FM robustness to non-biological features. Our work (i) introduces measures to quantify FM robustness, (ii) demonstrates the consequences of limited robustness, and (iii) proposes a framework for FM robustification to mitigate these issues. Specifically, we developed PathoROB, a robustness benchmark with three novel metrics, including the robustness index, and four datasets covering 28 biological classes from 34 medical centers. Our experiments reveal robustness deficits across all 20 evaluated FMs, and substantial robustness differences between them. We found that non-robust FM representations can cause major diagnostic downstream errors and clinical blunders that prevent safe clinical adoption. Using more robust FMs and post-hoc robustification considerably reduced (but did not yet eliminate) the risk of such errors. This work establishes that robustness evaluation is essential for validating pathology FMs before clinical adoption and demonstrates that future FM development must integrate robustness as a core design principle. PathoROB provides a blueprint for assessing robustness across biomedical domains, guiding FM improvement efforts towards more robust, representative, and clinically deployable AI systems that prioritize biological information over technical artifacts.

  • 12 authors
·
Jul 22, 2025

Generalist versus Specialist Vision Foundation Models for Ocular Disease and Oculomics

Medical foundation models, pre-trained with large-scale clinical data, demonstrate strong performance in diverse clinically relevant applications. RETFound, trained on nearly one million retinal images, exemplifies this approach in applications with retinal images. However, the emergence of increasingly powerful and multifold larger generalist foundation models such as DINOv2 and DINOv3 raises the question of whether domain-specific pre-training remains essential, and if so, what gap persists. To investigate this, we systematically evaluated the adaptability of DINOv2 and DINOv3 in retinal image applications, compared to two specialist RETFound models, RETFound-MAE and RETFound-DINOv2. We assessed performance on ocular disease detection and systemic disease prediction using two adaptation strategies: fine-tuning and linear probing. Data efficiency and adaptation efficiency were further analysed to characterise trade-offs between predictive performance and computational cost. Our results show that although scaling generalist models yields strong adaptability across diverse tasks, RETFound-DINOv2 consistently outperforms these generalist foundation models in ocular-disease detection and oculomics tasks, demonstrating stronger generalisability and data efficiency. These findings suggest that specialist retinal foundation models remain the most effective choice for clinical applications, while the narrowing gap with generalist foundation models suggests that continued data and model scaling can deliver domain-relevant gains and position them as strong foundations for future medical foundation models.

  • 23 authors
·
Sep 3, 2025

Anatomical Foundation Models for Brain MRIs

Deep Learning (DL) in neuroimaging has become increasingly relevant for detecting neurological conditions and neurodegenerative disorders. One of the most predominant biomarkers in neuroimaging is represented by brain age, which has been shown to be a good indicator for different conditions, such as Alzheimer's Disease. Using brain age for weakly supervised pre-training of DL models in transfer learning settings has also recently shown promising results, especially when dealing with data scarcity of different conditions. On the other hand, anatomical information of brain MRIs (e.g. cortical thickness) can provide important information for learning good representations that can be transferred to many downstream tasks. In this work, we propose AnatCL, an anatomical foundation model for brain MRIs that i.) leverages anatomical information in a weakly contrastive learning approach, and ii.) achieves state-of-the-art performances across many different downstream tasks. To validate our approach we consider 12 different downstream tasks for the diagnosis of different conditions such as Alzheimer's Disease, autism spectrum disorder, and schizophrenia. Furthermore, we also target the prediction of 10 different clinical assessment scores using structural MRI data. Our findings show that incorporating anatomical information during pre-training leads to more robust and generalizable representations. Pre-trained models can be found at: https://github.com/EIDOSLAB/AnatCL.

  • 4 authors
·
Aug 7, 2024

PathOrchestra: A Comprehensive Foundation Model for Computational Pathology with Over 100 Diverse Clinical-Grade Tasks

The complexity and variability inherent in high-resolution pathological images present significant challenges in computational pathology. While pathology foundation models leveraging AI have catalyzed transformative advancements, their development demands large-scale datasets, considerable storage capacity, and substantial computational resources. Furthermore, ensuring their clinical applicability and generalizability requires rigorous validation across a broad spectrum of clinical tasks. Here, we present PathOrchestra, a versatile pathology foundation model trained via self-supervised learning on a dataset comprising 300K pathological slides from 20 tissue and organ types across multiple centers. The model was rigorously evaluated on 112 clinical tasks using a combination of 61 private and 51 public datasets. These tasks encompass digital slide preprocessing, pan-cancer classification, lesion identification, multi-cancer subtype classification, biomarker assessment, gene expression prediction, and the generation of structured reports. PathOrchestra demonstrated exceptional performance across 27,755 WSIs and 9,415,729 ROIs, achieving over 0.950 accuracy in 47 tasks, including pan-cancer classification across various organs, lymphoma subtype diagnosis, and bladder cancer screening. Notably, it is the first model to generate structured reports for high-incidence colorectal cancer and diagnostically complex lymphoma-areas that are infrequently addressed by foundational models but hold immense clinical potential. Overall, PathOrchestra exemplifies the feasibility and efficacy of a large-scale, self-supervised pathology foundation model, validated across a broad range of clinical-grade tasks. Its high accuracy and reduced reliance on extensive data annotation underline its potential for clinical integration, offering a pathway toward more efficient and high-quality medical services.

  • 27 authors
·
Mar 31, 2025

Medical Hallucinations in Foundation Models and Their Impact on Healthcare

Foundation Models that are capable of processing and generating multi-modal data have transformed AI's role in medicine. However, a key limitation of their reliability is hallucination, where inaccurate or fabricated information can impact clinical decisions and patient safety. We define medical hallucination as any instance in which a model generates misleading medical content. This paper examines the unique characteristics, causes, and implications of medical hallucinations, with a particular focus on how these errors manifest themselves in real-world clinical scenarios. Our contributions include (1) a taxonomy for understanding and addressing medical hallucinations, (2) benchmarking models using medical hallucination dataset and physician-annotated LLM responses to real medical cases, providing direct insight into the clinical impact of hallucinations, and (3) a multi-national clinician survey on their experiences with medical hallucinations. Our results reveal that inference techniques such as Chain-of-Thought (CoT) and Search Augmented Generation can effectively reduce hallucination rates. However, despite these improvements, non-trivial levels of hallucination persist. These findings underscore the ethical and practical imperative for robust detection and mitigation strategies, establishing a foundation for regulatory policies that prioritize patient safety and maintain clinical integrity as AI becomes more integrated into healthcare. The feedback from clinicians highlights the urgent need for not only technical advances but also for clearer ethical and regulatory guidelines to ensure patient safety. A repository organizing the paper resources, summaries, and additional information is available at https://github.com/mitmedialab/medical hallucination.

  • 25 authors
·
Feb 25, 2025

SoftTiger: A Clinical Foundation Model for Healthcare Workflows

We introduce SoftTiger, a clinical large language model (CLaM) designed as a foundation model for healthcare workflows. The narrative and unstructured nature of clinical notes is a major obstacle for healthcare intelligentization. We address a critical problem of structuring clinical notes into clinical data, according to international interoperability standards. We collect and annotate data for three subtasks, namely, international patient summary, clinical impression and medical encounter. We then supervised fine-tuned a state-of-the-art LLM using public and credentialed clinical data. The training is orchestrated in a way that the target model can first support basic clinical tasks such as abbreviation expansion and temporal information extraction, and then learn to perform more complex downstream clinical tasks. Moreover, we address several modeling challenges in the healthcare context, e.g., extra long context window. Our blind pairwise evaluation shows that SoftTiger outperforms other popular open-source models and GPT-3.5, comparable to Gemini-pro, with a mild gap from GPT-4. We believe that LLMs may become a step-stone towards healthcare digitalization and democratization. Therefore, we publicly release SoftTiger models at scales of 13 billion and 70 billion parameters, as well as datasets and code for our innovative scalable evaluation, hopefully, making a significant contribution to the healthcare industry.

  • 5 authors
·
Feb 29, 2024

ChestX-Reasoner: Advancing Radiology Foundation Models with Reasoning through Step-by-Step Verification

Recent advances in reasoning-enhanced large language models (LLMs) and multimodal LLMs (MLLMs) have significantly improved performance in complex tasks, yet medical AI models often overlook the structured reasoning processes inherent in clinical practice. In this work, we present ChestX-Reasoner, a radiology diagnosis MLLM designed to leverage process supervision mined directly from clinical reports, reflecting the step-by-step reasoning followed by radiologists. We construct a large dataset by extracting and refining reasoning chains from routine radiology reports. Our two-stage training framework combines supervised fine-tuning and reinforcement learning guided by process rewards to better align model reasoning with clinical standards. We introduce RadRBench-CXR, a comprehensive benchmark featuring 59K visual question answering samples with 301K clinically validated reasoning steps, and propose RadRScore, a metric evaluating reasoning factuality, completeness, and effectiveness. ChestX-Reasoner outperforms existing medical and general-domain MLLMs in both diagnostic accuracy and reasoning ability, achieving 16%, 5.9%, and 18% improvements in reasoning ability compared to the best medical MLLM, the best general MLLM, and its base model, respectively, as well as 3.3%, 24%, and 27% improvements in outcome accuracy. All resources are open-sourced to facilitate further research in medical reasoning MLLMs.

  • 6 authors
·
Apr 29, 2025

EHRMamba: Towards Generalizable and Scalable Foundation Models for Electronic Health Records

Transformers have significantly advanced the modeling of Electronic Health Records (EHR), yet their deployment in real-world healthcare is limited by several key challenges. Firstly, the quadratic computational cost and insufficient context length of these models pose significant obstacles for hospitals in processing the extensive medical histories typical in EHR data. Additionally, existing models employ separate finetuning for each clinical task, complicating maintenance in healthcare environments. Moreover, these models focus exclusively on either clinical prediction or EHR forecasting, lacking the flexibility to perform well across both. To overcome these limitations, we introduce EHRMamba, a robust foundation model built on the Mamba architecture. EHRMamba can process sequences up to four times longer than previous models due to its linear computational cost. We also introduce a novel approach to Multitask Prompted Finetuning (MTF) for EHR data, which enables EHRMamba to simultaneously learn multiple clinical tasks in a single finetuning phase, significantly enhancing deployment and cross-task generalization. Furthermore, our model leverages the HL7 FHIR data standard to simplify integration into existing hospital systems. Alongside EHRMamba, we open-source Odyssey, a toolkit designed to support the development and deployment of EHR foundation models, with an emphasis on data standardization and interpretability. Our evaluations on the MIMIC-IV dataset demonstrate that EHRMamba advances state-of-the-art performance across 6 major clinical tasks and excels in EHR forecasting, marking a significant leap forward in the field.

  • 4 authors
·
May 23, 2024

Prostate-Specific Foundation Models for Enhanced Detection of Clinically Significant Cancer

Accurate prostate cancer diagnosis remains challenging. Even when using MRI, radiologists exhibit low specificity and significant inter-observer variability, leading to potential delays or inaccuracies in identifying clinically significant cancers. This leads to numerous unnecessary biopsies and risks of missing clinically significant cancers. Here we present prostate vision contrastive network (ProViCNet), prostate organ-specific vision foundation models for Magnetic Resonance Imaging (MRI) and Trans-Rectal Ultrasound imaging (TRUS) for comprehensive cancer detection. ProViCNet was trained and validated using 4,401 patients across six institutions, as a prostate cancer detection model on radiology images relying on patch-level contrastive learning guided by biopsy confirmed radiologist annotations. ProViCNet demonstrated consistent performance across multiple internal and external validation cohorts with area under the receiver operating curve values ranging from 0.875 to 0.966, significantly outperforming radiologists in the reader study (0.907 versus 0.805, p<0.001) for mpMRI, while achieving 0.670 to 0.740 for TRUS. We also integrated ProViCNet with standard PSA to develop a virtual screening test, and we showed that we can maintain the high sensitivity for detecting clinically significant cancers while more than doubling specificity from 15% to 38% (p<0.001), thereby substantially reducing unnecessary biopsies. These findings highlight that ProViCNet's potential for enhancing prostate cancer diagnosis accuracy and reduce unnecessary biopsies, thereby optimizing diagnostic pathways.

  • 17 authors
·
Feb 1, 2025

CellVTA: Enhancing Vision Foundation Models for Accurate Cell Segmentation and Classification

Cell instance segmentation is a fundamental task in digital pathology with broad clinical applications. Recently, vision foundation models, which are predominantly based on Vision Transformers (ViTs), have achieved remarkable success in pathology image analysis. However, their improvements in cell instance segmentation remain limited. A key challenge arises from the tokenization process in ViTs, which substantially reduces the spatial resolution of input images, leading to suboptimal segmentation quality, especially for small and densely packed cells. To address this problem, we propose CellVTA (Cell Vision Transformer with Adapter), a novel method that improves the performance of vision foundation models for cell instance segmentation by incorporating a CNN-based adapter module. This adapter extracts high-resolution spatial information from input images and injects it into the ViT through a cross-attention mechanism. Our method preserves the core architecture of ViT, ensuring seamless integration with pretrained foundation models. Extensive experiments show that CellVTA achieves 0.538 mPQ on the CoNIC dataset and 0.506 mPQ on the PanNuke dataset, which significantly outperforms the state-of-the-art cell segmentation methods. Ablation studies confirm the superiority of our approach over other fine-tuning strategies, including decoder-only fine-tuning and full fine-tuning. Our code and models are publicly available at https://github.com/JieZheng-ShanghaiTech/CellVTA.

  • 4 authors
·
Apr 1, 2025

VisionUnite: A Vision-Language Foundation Model for Ophthalmology Enhanced with Clinical Knowledge

The need for improved diagnostic methods in ophthalmology is acute, especially in the underdeveloped regions with limited access to specialists and advanced equipment. Therefore, we introduce VisionUnite, a novel vision-language foundation model for ophthalmology enhanced with clinical knowledge. VisionUnite has been pretrained on an extensive dataset comprising 1.24 million image-text pairs, and further refined using our proposed MMFundus dataset, which includes 296,379 high-quality fundus image-text pairs and 889,137 simulated doctor-patient dialogue instances. Our experiments indicate that VisionUnite outperforms existing generative foundation models such as GPT-4V and Gemini Pro. It also demonstrates diagnostic capabilities comparable to junior ophthalmologists. VisionUnite performs well in various clinical scenarios including open-ended multi-disease diagnosis, clinical explanation, and patient interaction, making it a highly versatile tool for initial ophthalmic disease screening. VisionUnite can also serve as an educational aid for junior ophthalmologists, accelerating their acquisition of knowledge regarding both common and underrepresented ophthalmic conditions. VisionUnite represents a significant advancement in ophthalmology, with broad implications for diagnostics, medical education, and understanding of disease mechanisms. The source code is at https://github.com/HUANGLIZI/VisionUnite.

  • 8 authors
·
Aug 5, 2024

MM-DINOv2: Adapting Foundation Models for Multi-Modal Medical Image Analysis

Vision foundation models like DINOv2 demonstrate remarkable potential in medical imaging despite their origin in natural image domains. However, their design inherently works best for uni-modal image analysis, limiting their effectiveness for multi-modal imaging tasks that are common in many medical fields, such as neurology and oncology. While supervised models perform well in this setting, they fail to leverage unlabeled datasets and struggle with missing modalities, a frequent challenge in clinical settings. To bridge these gaps, we introduce MM-DINOv2, a novel and efficient framework that adapts the pre-trained vision foundation model DINOv2 for multi-modal medical imaging. Our approach incorporates multi-modal patch embeddings, enabling vision foundation models to effectively process multi-modal imaging data. To address missing modalities, we employ full-modality masking, which encourages the model to learn robust cross-modality relationships. Furthermore, we leverage semi-supervised learning to harness large unlabeled datasets, enhancing both the accuracy and reliability of medical predictions. Applied to glioma subtype classification from multi-sequence brain MRI, our method achieves a Matthews Correlation Coefficient (MCC) of 0.6 on an external test set, surpassing state-of-the-art supervised approaches by +11.1%. Our work establishes a scalable and robust solution for multi-modal medical imaging tasks, leveraging powerful vision foundation models pre-trained on natural images while addressing real-world clinical challenges such as missing data and limited annotations.

TUM-AIMED AIMED
·
Sep 8, 2025

Pillar-0: A New Frontier for Radiology Foundation Models

Radiology plays an integral role in modern medicine, yet rising imaging volumes have far outpaced workforce growth. Foundation models offer a path toward assisting with the full spectrum of radiology tasks, but existing medical models remain limited: they process volumetric CT and MRI as low-fidelity 2D slices, discard critical grayscale contrast information, and lack evaluation frameworks that reflect real clinical practice. We introduce Pillar-0, a radiology foundation model pretrained on 42,990 abdomen-pelvis CTs, 86,411 chest CTs, 14,348 head CTs, and 11,543 breast MRIs from a large academic center, together with RATE, a scalable framework that extracts structured labels for 366 radiologic findings with near-perfect accuracy using LLMs. Across internal test sets of 14,230 abdomen-pelvis CTs, 10,646 chest CTs, 4,906 head CTs, and 1,585 breast MRIs, Pillar-0 establishes a new performance frontier, achieving mean AUROCs of 86.4, 88.0, 90.1, and 82.9, outperforming MedGemma (Google), MedImageInsight (Microsoft), Lingshu (Alibaba), and Merlin (Stanford) by 7.8-15.8 AUROC points and ranking best in 87.2\% (319/366) tasks. Pillar-0 similarly outperforms all baselines in an external validation on the Stanford Abdominal CT dataset, including Merlin (82.2 vs 80.6 AUROC). Pillar-0 extends to tasks beyond its pretraining, such as long-horizon lung cancer risk prediction, where it improves upon the state-of-the-art Sybil by 3.0 C-index points on NLST, and generalizes with gains of 5.9 (MGH) and 1.9 (CGMH). In brain hemorrhage detection, Pillar-0 obtained a >95 AUROC when using only 1/20th of the data of the next most sample efficient baseline. Pillar-0 and RATE together provide an open, clinically rigorous foundation for building high-performance radiology systems, enabling applications that were previously infeasible due to computational, data, and evaluation constraints.

YalaLab Yala Lab
·
Nov 21, 2025 2

Boosting Pathology Foundation Models via Few-shot Prompt-tuning for Rare Cancer Subtyping

Rare cancers comprise 20-25% of all malignancies but face major diagnostic challenges due to limited expert availability-especially in pediatric oncology, where they represent over 70% of cases. While pathology vision-language (VL) foundation models show promising zero-shot capabilities for common cancer subtyping, their clinical performance for rare cancers remains limited. Existing multi-instance learning (MIL) methods rely only on visual features, overlooking cross-modal knowledge and compromising interpretability critical for rare cancer diagnosis. To address this limitation, we propose PathPT, a novel framework that fully exploits the potential of vision-language pathology foundation models through spatially-aware visual aggregation and task-specific prompt tuning. Unlike conventional MIL, PathPT converts WSI-level supervision into fine-grained tile-level guidance by leveraging the zero-shot capabilities of VL models, thereby preserving localization on cancerous regions and enabling cross-modal reasoning through prompts aligned with histopathological semantics. We benchmark PathPT on eight rare cancer datasets(four adult and four pediatric) spanning 56 subtypes and 2,910 WSIs, as well as three common cancer datasets, evaluating four state-of-the-art VL models and four MIL frameworks under three few-shot settings. Results show that PathPT consistently delivers superior performance, achieving substantial gains in subtyping accuracy and cancerous region grounding ability. This work advances AI-assisted diagnosis for rare cancers, offering a scalable solution for improving subtyping accuracy in settings with limited access to specialized expertise.

  • 14 authors
·
Aug 21, 2025

Test-Time Adaptation for EEG Foundation Models: A Systematic Study under Real-World Distribution Shifts

Electroencephalography (EEG) foundation models have shown strong potential for learning generalizable representations from large-scale neural data, yet their clinical deployment is hindered by distribution shifts across clinical settings, devices, and populations. Test-time adaptation (TTA) offers a promising solution by enabling models to adapt to unlabeled target data during inference without access to source data, a valuable property in healthcare settings constrained by privacy regulations and limited labeled data. However, its effectiveness for EEG remains largely underexplored. In this work, we introduce NeuroAdapt-Bench, a systematic benchmark for evaluating test-time adaptation methods on EEG foundation models under realistic distribution shifts. We evaluate representative TTA approaches from other domains across multiple pretrained foundation models, diverse downstream tasks, and heterogeneous datasets spanning in-distribution, out-of-distribution, and extreme modality shifts (e.g., Ear-EEG). Our results show that standard TTA methods yield inconsistent gains and often degrade performance, with gradient-based approaches particularly prone to heavy degradation. In contrast, optimization-free methods demonstrate greater stability and more reliable improvements. These findings highlight the limitations of existing TTA techniques in EEG, provide guidance for future development, and underscore the need for domain-specific adaptation strategies.

  • 3 authors
·
Apr 17 2

Beyond Classification: A Cough Regression Benchmark for Respiratory Acoustic Foundation Models

Respiratory acoustic foundation models (FMs) excel at cough classification, yet their ability to predict continuous health quantities from cough audio remains largely unexplored, despite the clinical value of passive age, BMI, and disease probability estimation in settings where physical measurements are unavailable. We introduce the multi-model, multi-target cough regression benchmark evaluating five FMs (OPERA-CT, OPERA-CE, OPERA-GT, HeAR, M2D+Resp) across six targets on three datasets under subject-disjoint protocols, comparing linear, MLP-small, and full MLP regression heads. MLP-small beats the mean-predictor baseline on all tasks and linear probing in 23 of 30 model x task cases, with full MLP overfitting on small clinical data but recovering on larger sets, revealing a dataset size x head-capacity trade-off. HeAR leads within-dataset age regression on Coswara (9.12 yr MAE); its CIDRZ result is excluded from headline claims owing to possible HeAR-CIDRZ pretraining overlap. OPERA-GT is favored over OPERA-CT on age in all three datasets, with the CIDRZ margin within seed variance, extending a generative-pretraining advantage from breath to cough. HeAR and M2D+Resp reach near-full performance at N = 50 samples while OPERA models require N = 400. Cross-dataset transfer is strongly asymmetric as large diverse data generalises to small clinical populations (CoughVID to CIDRZ: -0.17 yr) but not vice versa (CIDRZ to Coswara: +2.43 yr, +26.6%).

Can Generalist Foundation Models Outcompete Special-Purpose Tuning? Case Study in Medicine

Generalist foundation models such as GPT-4 have displayed surprising capabilities in a wide variety of domains and tasks. Yet, there is a prevalent assumption that they cannot match specialist capabilities of fine-tuned models. For example, most explorations to date on medical competency benchmarks have leveraged domain-specific training, as exemplified by efforts on BioGPT and Med-PaLM. We build on a prior study of GPT-4's capabilities on medical challenge benchmarks in the absence of special training. Rather than using simple prompting to highlight the model's out-of-the-box capabilities, we perform a systematic exploration of prompt engineering. We find that prompting innovation can unlock deeper specialist capabilities and show that GPT-4 easily tops prior leading results for medical benchmarks. The prompting methods we explore are general purpose, and make no specific use of domain expertise, removing the need for expert-curated content. Our experimental design carefully controls for overfitting during the prompt engineering process. We introduce Medprompt, based on a composition of several prompting strategies. With Medprompt, GPT-4 achieves state-of-the-art results on all nine of the benchmark datasets in the MultiMedQA suite. The method outperforms leading specialist models such as Med-PaLM 2 by a significant margin with an order of magnitude fewer calls to the model. Steering GPT-4 with Medprompt achieves a 27% reduction in error rate on the MedQA dataset over the best methods to date achieved with specialist models and surpasses a score of 90% for the first time. Beyond medical problems, we show the power of Medprompt to generalize to other domains and provide evidence for the broad applicability of the approach via studies of the strategy on exams in electrical engineering, machine learning, philosophy, accounting, law, nursing, and clinical psychology.

  • 18 authors
·
Nov 27, 2023

EEGDash Corpus: A Training-Ready Public Corpus for EEG Foundation Models

Foundation models for electroencephalography (EEG) are pretrained on tens of thousands of hours of recordings, and their accuracy grows with that amount. Such data is hard to assemble. The largest sources are clinical archives that cannot be redistributed, and the public sources are spread over several archives, file formats, and licences. We release eegdash-corpus-v0, a training-ready corpus of 77 public EEG datasets, as the gated Hugging Face dataset EEGDash/eegdash-corpus-v0 with the SHA-256 of every file. REVE, the largest published EEG foundation model, names 89 datasets as its pretraining corpus. Twelve cannot be redistributed: four clinical archives that hold 82% of its hours, and eight under no-derivatives licences. The corpus holds the 76 others that REVE's sampling rate allows and one more from REVE's release card: 77 datasets, 14,075 hours from 7,272 subjects, 5.0 million 10-second samples and 6.21 billion tokens per epoch. Every dataset is fetched through EEGDash, converted once with REVE's recipe, and stored in its own buckets of a chunked Zarr store with its licence recorded beside it, so a model can train on the whole store or on any subset of datasets. To test that the store pretrains a model, we retrain REVE-Base from scratch twice with the authors' code, changed only in how it reads data, and score it on seven public OpenEEGBench tasks. It reaches 0.331 under linear probing and 0.273 after fine-tuning, against 0.333 and 0.325 for the released model and 0.200 and 0.205 for an untrained encoder. The converter, the conversion reports, and the loader changes are released with the corpus.

  • 3 authors
·
Nov 3

Large-scale Training of Foundation Models for Wearable Biosignals

Tracking biosignals is crucial for monitoring wellness and preempting the development of severe medical conditions. Today, wearable devices can conveniently record various biosignals, creating the opportunity to monitor health status without disruption to one's daily routine. Despite widespread use of wearable devices and existing digital biomarkers, the absence of curated data with annotated medical labels hinders the development of new biomarkers to measure common health conditions. In fact, medical datasets are usually small in comparison to other domains, which is an obstacle for developing neural network models for biosignals. To address this challenge, we have employed self-supervised learning using the unlabeled sensor data collected under informed consent from the large longitudinal Apple Heart and Movement Study (AHMS) to train foundation models for two common biosignals: photoplethysmography (PPG) and electrocardiogram (ECG) recorded on Apple Watch. We curated PPG and ECG datasets from AHMS that include data from ~141K participants spanning ~3 years. Our self-supervised learning framework includes participant level positive pair selection, stochastic augmentation module and a regularized contrastive loss optimized with momentum training, and generalizes well to both PPG and ECG modalities. We show that the pre-trained foundation models readily encode information regarding participants' demographics and health conditions. To the best of our knowledge, this is the first study that builds foundation models using large-scale PPG and ECG data collected via wearable consumer devices x2013 prior works have commonly used smaller-size datasets collected in clinical and experimental settings. We believe PPG and ECG foundation models can enhance future wearable devices by reducing the reliance on labeled data and hold the potential to help the users improve their health.

  • 6 authors
·
Dec 8, 2023

A Multimodal Vision Foundation Model for Clinical Dermatology

Diagnosing and treating skin diseases require advanced visual skills across domains and the ability to synthesize information from multiple imaging modalities. While current deep learning models excel at specific tasks like skin cancer diagnosis from dermoscopic images, they struggle to meet the complex, multimodal requirements of clinical practice. Here, we introduce PanDerm, a multimodal dermatology foundation model pretrained through self-supervised learning on over 2 million real-world skin disease images from 11 clinical institutions across 4 imaging modalities. We evaluated PanDerm on 28 diverse benchmarks, including skin cancer screening, risk stratification, differential diagnosis of common and rare skin conditions, lesion segmentation, longitudinal monitoring, and metastasis prediction and prognosis. PanDerm achieved state-of-the-art performance across all evaluated tasks, often outperforming existing models when using only 10% of labeled data. We conducted three reader studies to assess PanDerm's potential clinical utility. PanDerm outperformed clinicians by 10.2% in early-stage melanoma detection through longitudinal analysis, improved clinicians' skin cancer diagnostic accuracy by 11% on dermoscopy images, and enhanced non-dermatologist healthcare providers' differential diagnosis by 16.5% across 128 skin conditions on clinical photographs. These results demonstrate PanDerm's potential to improve patient care across diverse clinical scenarios and serve as a model for developing multimodal foundation models in other medical specialties, potentially accelerating the integration of AI support in healthcare. The code can be found at https://github.com/SiyuanYan1/PanDerm.

  • 25 authors
·
Oct 19, 2024

Surg$Σ$: A Spectrum of Large-Scale Multimodal Data and Foundation Models for Surgical Intelligence

Surgical intelligence has the potential to improve the safety and consistency of surgical care, yet most existing surgical AI frameworks remain task-specific and struggle to generalize across procedures and institutions. Although multimodal foundation models, particularly multimodal large language models, have demonstrated strong cross-task capabilities across various medical domains, their advancement in surgery remains constrained by the lack of large-scale, systematically curated multimodal data. To address this challenge, we introduce SurgΣ, a spectrum of large-scale multimodal data and foundation models for surgical intelligence. At the core of this framework lies SurgΣ-DB, a large-scale multimodal data foundation designed to support diverse surgical tasks. SurgΣ-DB consolidates heterogeneous surgical data sources (including open-source datasets, curated in-house clinical collections and web-source data) into a unified schema, aiming to improve label consistency and data standardization across heterogeneous datasets. SurgΣ-DB spans 6 clinical specialties and diverse surgical types, providing rich image- and video-level annotations across 18 practical surgical tasks covering understanding, reasoning, planning, and generation, at an unprecedented scale (over 5.98M conversations). Beyond conventional multimodal conversations, SurgΣ-DB incorporates hierarchical reasoning annotations, providing richer semantic cues to support deeper contextual understanding in complex surgical scenarios. We further provide empirical evidence through recently developed surgical foundation models built upon SurgΣ-DB, illustrating the practical benefits of large-scale multimodal annotations, unified semantic design, and structured reasoning annotations for improving cross-task generalization and interpretability.

  • 16 authors
·
Mar 16

MedPMC: A Systematic Framework for Scaling High-Fidelity Medical Multimodal Data for Foundation Models

Medicine is inherently multimodal, requiring clinicians to synthesize information across diverse data streams. Yet the development of multimodal foundation models is constrained by limited access to large-scale, high-quality clinical data. Although PubMed Central (PMC) offers a complementary source of expert-authored image-text data, existing PMC-derived resources remain limited in fidelity, reproducibility, and clinical validation. We introduce MedPMC, an automated, continuously updatable framework that transforms permissively licensed literature into high-fidelity infrastructure for medical multimodal models. Applied to 6.1 million PMC articles, MedPMC curated 11 million medical image-text pairs. Component evaluations showed strong performance for initial screening (F1 = 93.2), multi-panel figure detection (F1 = 96.5), figure separation (mAP = 89.8), caption separation and alignment (F1 = 81.4; ROUGE-L = 85.3), and medical figure classification (F1 = 96.5). Manual review by five annotators, three with medical training, found 95.3% of MedPMC images medically relevant, versus 19.7% in a prior PMC-derived dataset. Across 26 benchmarks spanning 11 specialties, a MedPMC-trained CLIP-style model improved average zero-shot AUC by 7.1 percentage points over the strongest architecture-matched biomedical CLIP baseline despite using fewer than half as many image-text pairs. As the vision encoder in a multimodal large language model, it improved medical visual question-answering by 1.9 and 16.9 percentage points across two benchmarks. In 10,524 Yale New Haven Health System dermatology photographs, it improved morphology-to-image retrieval Recall@5 by 11.7 percentage points. These findings show that high-fidelity literature curation strengthens medical multimodal foundation models across benchmark and clinical settings. We publicly release the framework, corpus, benchmarks, and pretrained models.

Location-Aware Fine-Grained Representation Learning for Medical Vision Foundation Models

Fine-grained visual representations are essential for medical image analysis, particularly when diagnostically relevant evidence is subtle and spatially localized. Modern transformer-based medical vision encoders must therefore learn patch-level representations that are both clinically meaningful and spatially consistent. Without these properties, large vision-language models (LVLMs) operate on an ambiguous visual foundation, limiting their ability to generate clinically reliable and spatially grounded responses. However, existing training strategies for medical vision encoders rarely achieve both objectives. Image-text alignment provides clinically meaningful supervision primarily at the image level, leaving the spatial localization of diagnostic evidence weakly constrained. In contrast, self-supervised learning promotes spatial consistency but lacks the semantic supervision needed to distinguish visually similar yet clinically distinct regions. To address this gap, we present LoFi, a medical vision foundation model built on location-aware fine-grained representation learning. LoFi trains a vision encoder with a lightweight large language model under grounding and grounded captioning objectives. Because these objectives require predicting location from clinical text and vice versa, spatial consistency emerges without any explicit patch-level regularization. To enable training at scale, we construct MedG, a large-scale medical grounding dataset of 4.48M image-text-box triplets curated from 84 datasets spanning 7 modalities. Across phrase grounding, visual question answering, and region-based organ classification under perturbations, LoFi consistently outperforms general-purpose and medical vision foundation models as well as state-of-the-art LVLMs. Code is available at https://github.com/myeongkyunkang/lofi-medg.

  • 3 authors
·
Aug 1

Do 3D Medical Foundation Models See Through MRI Artifacts? A Controlled Study of Representation Robustness

Self-supervised 3D medical foundation models are increasingly used as general-purpose feature extractors, yet their sensitivity to MRI artifacts remains poorly understood. We present a controlled evaluation of representation robustness across five pretrained 3D encoders spanning different architectures, objectives, pretraining domains, and dataset scales. Using BraTS-Africa cases with four MRI sequences, we generate seven frequency- and image-domain artifacts at five predefined corruption settings. Robustness is assessed using linear centered kernel alignment (CKA), RankMe, and UMAP, complemented by an independent segmentation-consistency analysis. We find that robustness is strongly model- and artifact-dependent. 3DINO exhibits the most consistently stable representations, while BrainIAC is highly sensitive to several corruptions; NeuroVFM, BrainFM, and Neuro-SimCLR show intermediate but distinct artifact-specific profiles. Across many conditions, CKA decreases substantially while RankMe remains comparatively stable, indicating that artifacts often distort representation geometry without causing dimensional collapse. Segmentation consistency also degrades under corruption, particularly for ghosting and Rician noise, but aligns only partially with representation-level robustness. These findings show that larger-scale or domain-specific pretraining alone does not guarantee artifact invariance and motivate explicit robustness evaluation before deploying 3D foundation models in heterogeneous MRI settings.

  • 3 authors
·
Aug 5

OpenMEDLab: An Open-source Platform for Multi-modality Foundation Models in Medicine

The emerging trend of advancing generalist artificial intelligence, such as GPTv4 and Gemini, has reshaped the landscape of research (academia and industry) in machine learning and many other research areas. However, domain-specific applications of such foundation models (e.g., in medicine) remain untouched or often at their very early stages. It will require an individual set of transfer learning and model adaptation techniques by further expanding and injecting these models with domain knowledge and data. The development of such technologies could be largely accelerated if the bundle of data, algorithms, and pre-trained foundation models were gathered together and open-sourced in an organized manner. In this work, we present OpenMEDLab, an open-source platform for multi-modality foundation models. It encapsulates not only solutions of pioneering attempts in prompting and fine-tuning large language and vision models for frontline clinical and bioinformatic applications but also building domain-specific foundation models with large-scale multi-modal medical data. Importantly, it opens access to a group of pre-trained foundation models for various medical image modalities, clinical text, protein engineering, etc. Inspiring and competitive results are also demonstrated for each collected approach and model in a variety of benchmarks for downstream tasks. We welcome researchers in the field of medical artificial intelligence to continuously contribute cutting-edge methods and models to OpenMEDLab, which can be accessed via https://github.com/openmedlab.

  • 20 authors
·
Feb 27, 2024

Neural State Prediction: Obstructing Shortcut Learning in EEG Foundation Models

EEG foundation models increasingly use masked prediction to learn from unlabeled recordings, but optimizing this objective does not ensure transferable neural representations. A central challenge is that stable positional cues and local correlations can make masked regions predictable without integrating distributed neural context. To reduce this reliance on low-information prediction paths, we introduce Neural State Prediction (NSP), a latent-predictive framework that constrains both the prediction target and the available context. NSP uses a Target Encoder updated by an exponential moving average (EMA) to define latent supervision. Identity residualization removes additive effects associated with channel identity and relative time from the targets, while topology-separated context excludes their immediate spatial and temporal neighborhood from the visible input. We pretrain NSP on 2.2 million EEG segments from TUEG and evaluate it across 30 downstream datasets spanning clinical diagnosis, sleep staging, emotion recognition, motor imagery, event-related potentials, cognitive-state decoding, and language retrieval. Under full-parameter multi-task fine-tuning on EEG-FM-Bench, NSP achieves 63.94 macro balanced accuracy across 14 datasets, exceeding the strongest evaluated baseline by 2.35 percentage points. Controlled component ablations assess the contribution of each mechanism, while matched context controls and held-out interventions characterize the role of context geometry, signal content, and positional information. Jointly designing latent targets and their context offers a promising direction for EEG foundation models that learn from distributed signal structure.

  • 5 authors
·
Sep 25

Dino U-Net: Exploiting High-Fidelity Dense Features from Foundation Models for Medical Image Segmentation

Foundation models pre-trained on large-scale natural image datasets offer a powerful paradigm for medical image segmentation. However, effectively transferring their learned representations for precise clinical applications remains a challenge. In this work, we propose Dino U-Net, a novel encoder-decoder architecture designed to exploit the high-fidelity dense features of the DINOv3 vision foundation model. Our architecture introduces an encoder built upon a frozen DINOv3 backbone, which employs a specialized adapter to fuse the model's rich semantic features with low-level spatial details. To preserve the quality of these representations during dimensionality reduction, we design a new fidelity-aware projection module (FAPM) that effectively refines and projects the features for the decoder. We conducted extensive experiments on seven diverse public medical image segmentation datasets. Our results show that Dino U-Net achieves state-of-the-art performance, consistently outperforming previous methods across various imaging modalities. Our framework proves to be highly scalable, with segmentation accuracy consistently improving as the backbone model size increases up to the 7-billion-parameter variant. The findings demonstrate that leveraging the superior, dense-pretrained features from a general-purpose foundation model provides a highly effective and parameter-efficient approach to advance the accuracy of medical image segmentation. The code is available at https://github.com/yifangao112/DinoUNet.

  • 5 authors
·
Aug 28, 2025

Computational Pathology at Health System Scale -- Self-Supervised Foundation Models from Three Billion Images

Recent breakthroughs in self-supervised learning have enabled the use of large unlabeled datasets to train visual foundation models that can generalize to a variety of downstream tasks. While this training paradigm is well suited for the medical domain where annotations are scarce, large-scale pre-training in the medical domain, and in particular pathology, has not been extensively studied. Previous work in self-supervised learning in pathology has leveraged smaller datasets for both pre-training and evaluating downstream performance. The aim of this project is to train the largest academic foundation model and benchmark the most prominent self-supervised learning algorithms by pre-training and evaluating downstream performance on large clinical pathology datasets. We collected the largest pathology dataset to date, consisting of over 3 billion images from over 423 thousand microscopy slides. We compared pre-training of visual transformer models using the masked autoencoder (MAE) and DINO algorithms. We evaluated performance on six clinically relevant tasks from three anatomic sites and two institutions: breast cancer detection, inflammatory bowel disease detection, breast cancer estrogen receptor prediction, lung adenocarcinoma EGFR mutation prediction, and lung cancer immunotherapy response prediction. Our results demonstrate that pre-training on pathology data is beneficial for downstream performance compared to pre-training on natural images. Additionally, the DINO algorithm achieved better generalization performance across all tasks tested. The presented results signify a phase change in computational pathology research, paving the way into a new era of more performant models based on large-scale, parallel pre-training at the billion-image scale.

  • 13 authors
·
Oct 10, 2023

OrganLens: Organ-Specific Representation Learning for CT Foundation Models

A CT examination captures multiple organs, but many biomedical questions concern abnormalities, prognosis, or longitudinal change in a specific organ. These questions require a separate representation for each organ within the same CT volume. Existing CT foundation models commonly produce a single volume-level representation, while recent anatomy-aware methods either encode pre-separated organ volumes or explicitly disentangle images into organ token groups. The former may remove clinically relevant surrounding context, while the latter does not condition a shared encoder on a selected organ before its features are formed. We introduce OrganLens for organ-specific representation learning through self-supervision. An organ identity conditions a shared CT encoder, while organ-specific distillation and anatomy-mask supervision shape features for anatomy-weighted pooling into organ-specific representations. At inference, the shared model produces 11 organ-specific representations without external segmentation masks. We evaluate OrganLens on CT-RATE, RAD-ChestCT, INSPECT, and NLST across diverse acquisitions and downstream evaluations. Relative to CT-pretrained DINOv2, heart representations raise CT-RATE cardiomegaly AUROC from 0.910 to 0.953, while lung representations improve the Harrell C-index for NLST lung-cancer mortality by 14.2\%. The global representation reaches INSPECT Recall@10 of 33.09\% and 32.04\% for text-to-image and image-to-text retrieval, respectively. Across organ-related tasks, anatomically matched representations provide stronger task-relevant signal, while the global representation retains broad utility. OrganLens offers a scalable approach to organ-specific CT representation learning with a shared encoder. More broadly, it provides the medical research community with a reusable framework for studying organ-specific disease across cohorts and clinical endpoints.

  • 5 authors
·
Jul 27

GigaPath-Flash and GigaTIME-Flash: Efficient Pathology Foundation Models for Whole-Slide and Tumor Microenvironment Analysis

Foundation models have emerged as a driving force in computational pathology, with the potential to transform cancer diagnosis, prognosis, and treatment selection by learning transferable representations from large-scale histopathology data. A growing landscape of pathology foundation models now spans diverse data sources, architectures, and downstream applications. However, most pretrained models operate only at the image-tile level, use restrictive licenses, and remain computationally expensive, limiting large-scale slide-level clinical and research use. Here, we introduce GigaPath-Flash and GigaTIME-Flash, efficient models for whole-slide pathology AI and spatial proteomics prediction. GigaPath-Flash combines a 22M-parameter ViT-S tile encoder with a 21M-parameter LongNet slide encoder, both pretrained on large-scale real-world histopathology data. Its compact tile encoder is distilled from the billion-parameter GigaPath (ViT-g) teacher and shared by both models. GigaPath-Flash retains 97% of GigaPath's average slide-level performance with 50x less compute. GigaTIME-Flash extends this backbone to predict the tumor immune microenvironment directly from routine H&E images. It surpasses the original CNN-based GigaTIME in prediction quality while running 6x faster and using 8x less GPU memory. Together with GigaPath and GigaTIME, these models form an open-weight, Apache-2.0-licensed family pretrained on large-scale real-world clinical data. By releasing all models and weights, we provide accessible building blocks for computational pathology, immuno-oncology, and precision health.

  • 30 authors
·
Jul 21

MIPHEI-ViT: Multiplex Immunofluorescence Prediction from H&E Images using ViT Foundation Models

Histopathological analysis is a cornerstone of cancer diagnosis, with Hematoxylin and Eosin (H&E) staining routinely acquired for every patient to visualize cell morphology and tissue architecture. On the other hand, multiplex immunofluorescence (mIF) enables more precise cell type identification via proteomic markers, but has yet to achieve widespread clinical adoption due to cost and logistical constraints. To bridge this gap, we introduce MIPHEI (Multiplex Immunofluorescence Prediction from H&E), a U-Net-inspired architecture that integrates state-of-the-art ViT foundation models as encoders to predict mIF signals from H&E images. MIPHEI targets a comprehensive panel of markers spanning nuclear content, immune lineages (T cells, B cells, myeloid), epithelium, stroma, vasculature, and proliferation. We train our model using the publicly available ORION dataset of restained H&E and mIF images from colorectal cancer tissue, and validate it on two independent datasets. MIPHEI achieves accurate cell-type classification from H&E alone, with F1 scores of 0.88 for Pan-CK, 0.57 for CD3e, 0.56 for SMA, 0.36 for CD68, and 0.30 for CD20, substantially outperforming both a state-of-the-art baseline and a random classifier for most markers. Our results indicate that our model effectively captures the complex relationships between nuclear morphologies in their tissue context, as visible in H&E images and molecular markers defining specific cell types. MIPHEI offers a promising step toward enabling cell-type-aware analysis of large-scale H&E datasets, in view of uncovering relationships between spatial cellular organization and patient outcomes.

  • 5 authors
·
May 15, 2025

MedHEB: Benchmarking Medical Embeddings Across Heterogeneous Clinical Evidence

Clinical evidence is inherently relational: medical images are interpreted with prior studies, cross-modal examinations, reports, and localized findings, and retrieving relevant evidence is therefore central to clinical interpretation. Recent foundation models increasingly encode these heterogeneous sources into shared embedding spaces, yet existing embedding evaluation often focuses on isolated matches, leaving unclear whether current models retrieve relevant evidence across changes in modality, appearance, and granularity. We introduce MedHEB, a unified benchmark with 107 retrieval tasks from 54 datasets, including both in-distribution and held-out-source evaluation, across three axes: evidence form (2D images, 3D volumes, text), pairing type (image--image, image--text, text--text, and modality-bridging visual matching), and relevance granularity (global, question-conditioned, region-level). Under a single ranking protocol, MedHEB varies clinically relevant evidence definitions to test whether embedding proximity remains meaningful across heterogeneous evidence, including modality-bridging visual retrieval and region-level text-to-region retrieval. Across representative models, performance is uneven across retrieval families: models strong on conventional image--text or text--text retrieval are less reliable on modality-bridging and region-level tasks. Current embedding spaces capture some clinical relationships well but do not yet provide balanced retrieval across heterogeneous evidence. We further provide MedEmb, an MLLM-based reference embedding model trained on the MedHEB ID split, as a reproducible baseline for unified 2D--3D--text medical retrieval. We release MedHEB with preprocessing scripts, evaluation code, access manifests, and MedEmb to support research on clinically meaningful medical embeddings.

  • 9 authors
·
Nov 1

Glyph: An Interpretability Engine for AI-Driven Scientific Discovery in Clinical Data

Automated scientific discovery has the potential to advance understanding of disease mechanisms and accelerate identification of early disease markers. Manual data annotation is infeasible at population scale, motivating methods that automatically extract pre-defined phenotypes in multimodal and unstructured clinical data. Such pre-defined feature sets determine and limit which associations these approaches can discover. This limitation extends to agentic AI systems that use these tools to query population-scale data. In contrast, foundation models (FMs) trained on large volumes of clinical data can perform tasks beyond their training objectives. This suggests their latent embeddings may represent novel or unexplored features that could yield insights into disease mechanisms, yet such latent features remain difficult to interpret. To address this challenge, we introduce Glyph, an automated multistage framework that extracts features from multimodal and unstructured clinical data using FMs and sparse autoencoders, interprets them as coded clinical concepts, and evaluates their value for clinical scientific discovery. We applied Glyph to abdominal CT volumes, CT radiology reports and laboratory measurements from 41,628 patients across different institutions. We identified 397 predictive concepts supported by 4,463 Bonferroni-significant associations. Moreover, a majority of discovered associations were automatically reproducible in held-out cohorts across different sites. Glyph concepts provided complementary associations to literature-derived markers, leading to gains in predictive power. We envision that interpretability can extend beyond a mechanistic understanding of neural networks to connecting implicitly learned features with clinical knowledge and establishing their significance for patient outcomes. We release Glyph at https://github.com/StanfordMIMI/Glyph.

  • 22 authors
·
Nov 5

PRISM: A Multi-Modal Generative Foundation Model for Slide-Level Histopathology

Foundation models in computational pathology promise to unlock the development of new clinical decision support systems and models for precision medicine. However, there is a mismatch between most clinical analysis, which is defined at the level of one or more whole slide images, and foundation models to date, which process the thousands of image tiles contained in a whole slide image separately. The requirement to train a network to aggregate information across a large number of tiles in multiple whole slide images limits these models' impact. In this work, we present a slide-level foundation model for H&E-stained histopathology, PRISM, that builds on Virchow tile embeddings and leverages clinical report text for pre-training. Using the tile embeddings, PRISM produces slide-level embeddings with the ability to generate clinical reports, resulting in several modes of use. Using text prompts, PRISM achieves zero-shot cancer detection and sub-typing performance approaching and surpassing that of a supervised aggregator model. Using the slide embeddings with linear classifiers, PRISM surpasses supervised aggregator models. Furthermore, we demonstrate that fine-tuning of the PRISM slide encoder yields label-efficient training for biomarker prediction, a task that typically suffers from low availability of training data; an aggregator initialized with PRISM and trained on as little as 10% of the training data can outperform a supervised baseline that uses all of the data.

  • 22 authors
·
May 16, 2024

Free Lunch in Medical Image Foundation Model Pre-training via Randomized Synthesis and Disentanglement

Medical image foundation models (MIFMs) have demonstrated remarkable potential for a wide range of clinical tasks, yet their development is constrained by the scarcity, heterogeneity, and high cost of large-scale annotated datasets. Here, we propose RaSD (Randomized Synthesis and Disentanglement), a scalable framework for pre-training MIFMs entirely on synthetic data. By modeling anatomical structures and appearance variations with randomized Gaussian distributions, RaSD exposes models to sufficient multi-scale structural and appearance perturbations, forcing them to rely on invariant and task-relevant anatomical cues rather than dataset-specific textures, thereby enabling robust and transferable representation learning. We pre-trained RaSD on 1.2 million 3D volumes and 9.6 million 2D images, and extensively evaluated the resulting models across 6 imaging modalities, 48 datasets, and 56 downstream tasks. Across all evaluated downstream tasks, RaSD consistently outperforms training-from-scratch models, achieves the best performance on 17 tasks, and remains comparable to models pre-trained on large real datasets in most others. These results demonstrate that the capacity of synthetic data alone to drive robust representation learning. Our findings establish a paradigm shift in medical AI, demonstrating that synthetic data can serve as a "free lunch" for scalable, privacy-preserving, and clinically generalizable foundation models.

  • 6 authors
·
Feb 11

Streamline pathology foundation model by cross-magnification distillation

Foundation models (FM) have transformed computational pathology but remain computationally prohibitive for clinical deployment due to their massive parameter counts and high-magnification processing requirements. Here, we introduce XMAG, a lightweight FM developed through corss-magnification distillation that transfers knowledge from state-of-the-art 20x magnification teacher to an efficient 5x magnification student architecture. XMAG employs a compact backbone and operates entirely at 5x, requiring 11.3 times fewer patches per whole slide image (WSI) compared to existing approaches. Our Novel distillation framework incorporates dual-level knowledge transfer, aligning both global image representations and local spatial token mapping. We trained XMAG on 3.49 million images curated from publicly available datasets and evaluated performance across six clinically relevant histopathology analysis tasks spanning multiple cancer types. XMAG achieved diagnostic accuracy within 1% of substantially larger foundation models while delivering 30-fold processing acceleration, reaching 8.8 WSIs per minute processing speed. Our cross-institutional validation confirmed robust generalization. Further, we developed an end-to-end training strategy to further boost our model's performance to approach the larger FMs' performance. These results establish cross-magnification distillation as a viable approach for deploying FM capabilities in resource-constrained clinical environments, potentially enabling real-time pathology AI integration.

  • 5 authors
·
Mar 10

Towards A Generalizable Pathology Foundation Model via Unified Knowledge Distillation

Foundation models pretrained on large-scale datasets are revolutionizing the field of computational pathology (CPath). The generalization ability of foundation models is crucial for the success in various downstream clinical tasks. However, current foundation models have only been evaluated on a limited type and number of tasks, leaving their generalization ability and overall performance unclear. To address this gap, we established a most comprehensive benchmark to evaluate the performance of off-the-shelf foundation models across six distinct clinical task types, encompassing a total of 39 specific tasks. Our findings reveal that existing foundation models excel at certain task types but struggle to effectively handle the full breadth of clinical tasks. To improve the generalization of pathology foundation models, we propose a unified knowledge distillation framework consisting of both expert and self knowledge distillation, where the former allows the model to learn from the knowledge of multiple expert models, while the latter leverages self-distillation to enable image representation learning via local-global alignment. Based on this framework, a Generalizable Pathology Foundation Model (GPFM) is pretrained on a large-scale dataset consisting of 190 million images from around 86,000 public H&E whole slides across 34 major tissue types. Evaluated on the established benchmark, GPFM achieves an impressive average rank of 1.36, with 29 tasks ranked 1st, while the the second-best model, UNI, attains an average rank of 2.96, with only 4 tasks ranked 1st. The superior generalization of GPFM demonstrates its exceptional modeling capabilities across a wide range of clinical tasks, positioning it as a new cornerstone for feature representation in CPath.

  • 16 authors
·
Jul 25, 2024

Learning Robust Visual Features in Computed Tomography Enables Efficient Transfer Learning for Clinical Tasks

There is substantial interest in developing artificial intelligence systems to support radiologists across tasks ranging from segmentation to report generation. Existing computed tomography (CT) foundation models have largely focused on building generalist vision-language systems capable of tasks such as question answering and report generation. However, training reliable vision-language systems requires paired image-text data at a scale that remains unavailable in CT. Moreover, adapting the underlying visual representations to downstream tasks typically requires partial or full backbone fine-tuning, a computationally demanding process inaccessible to many research groups. Instead, foundation models should prioritise learning robust visual representations that enable efficient transfer to new tasks with minimal labelled data and without backbone fine-tuning. We present VoxelFM, a 3D CT foundation model trained with self-distillation using the DINO framework, which learns semantically rich features without language supervision. We evaluated VoxelFM across seven categories of clinically relevant downstream tasks using frozen backbone representations with lightweight probes: classification, regression, survival analysis, instance retrieval, localisation, segmentation, and report generation. VoxelFM matched or outperformed four existing CT foundation models across all task categories. Despite receiving no language supervision during pre-training, VoxelFM surpassed models explicitly trained with language-alignment objectives, including on report generation. Our results indicate that current CT foundation models perform significantly better as feature extractors for lightweight probes rather than as vision encoders for vision-language models. Model weights and training code are publicly available.

  • 5 authors
·
Apr 4

MOOZY: A Patient-First Foundation Model for Computational Pathology

Computational pathology needs whole-slide image (WSI) foundation models that transfer across diverse clinical tasks, yet current approaches remain largely slide-centric, often depend on private data and expensive paired-report supervision, and do not explicitly model relationships among multiple slides from the same patient. We present MOOZY, a patient-first pathology foundation model in which the patient case, not the individual slide, is the core unit of representation. MOOZY explicitly models dependencies across all slides from the same patient via a case transformer during pretraining, combining multi-stage open self-supervision with scaled low-cost task supervision. In Stage 1, we pretrain a vision-only slide encoder on 77,134 public slide feature grids using masked self-distillation. In Stage 2, we align these representations with clinical semantics using a case transformer and multi-task supervision over 333 tasks from 56 public datasets, including 205 classification and 128 survival tasks across four endpoints. Across eight held-out tasks with five-fold frozen-feature probe evaluation, MOOZY achieves best or tied-best performance on most metrics and improves macro averages over TITAN by +7.37%, +5.50%, and +7.83% and over PRISM by +8.83%, +10.70%, and +9.78% for weighted F1, weighted ROC-AUC, and balanced accuracy, respectively. MOOZY is also parameter efficient with 85.77M parameters, 14x smaller than GigaPath. These results demonstrate that open, reproducible patient-level pretraining yields transferable embeddings, providing a practical path toward scalable patient-first histopathology foundation models.

Unified Multi-Foundation-Model Slide Representation for Pan-Cancer Recognition and Text-Guided Tumor Localization

The expanding ecosystem of pathology foundation models has produced powerful but fragmented tile-level representations, limiting their use in clinical tasks that require unified slide-level reasoning and interpretable linkage to clinically meaningful information. We present ASTRA, a pan-cancer framework that integrates heterogeneous foundation-model representations into a shared slide-level representation space and semantically grounds that space using structured pathology annotation fields, including classification category, cancer type, and anatomic site. ASTRA combines sparse mixture-of-experts contextualization, masked multi-model reconstruction, and contrastive alignment to structured pathology prompts to learn slide representations that support 4-category classification, 3-class solid tumor typing, 16-class cancer typing, and text-guided tumor localization without pixel-level supervision. Developed on a CHTN cohort of 10,359 whole-slide images (WSIs) spanning 16 tumor types, ASTRA consistently improves pan-cancer classification across four pathology foundation-model backbones, achieving up to 97.8% macro-AUC for 4-category classification, 99.7% for 3-class solid tumor typing, and 99.2% for 16-class cancer typing. For tumor localization, ASTRA achieves a mean Dice of 0.897 on an annotated in-domain CHTN subset (n = 380) spanning 16 cancer types and 0.738 on an external TCGA cohort (n = 1,686) spanning four cancer types. These results demonstrate that minimal structured pathology annotation fields derived from slide-level metadata can provide effective semantic supervision for unified slide representation learning, enabling both pan-cancer prediction and weakly supervised tumor localization within a single framework.

  • 9 authors
·
Apr 20

CureAgent: A Training-Free Executor-Analyst Framework for Clinical Reasoning

Current clinical agent built on small LLMs, such as TxAgent suffer from a Context Utilization Failure, where models successfully retrieve biomedical evidence due to supervised finetuning but fail to ground their diagnosis in that information. In this work, we propose the Executor-Analyst Framework, a modular architecture that decouples the syntactic precision of tool execution from the semantic robustness of clinical reasoning. By orchestrating specialized TxAgents (Executors) with long-context foundation models (Analysts), we mitigate the reasoning deficits observed in monolithic models. Beyond simple modularity, we demonstrate that a Stratified Ensemble strategy significantly outperforms global pooling by preserving evidentiary diversity, effectively addressing the information bottleneck. Furthermore, our stress tests reveal critical scaling insights: (1) a Context-Performance Paradox, where extending reasoning contexts beyond 12k tokens introduces noise that degrades accuracy; and (2) the Curse of Dimensionality in action spaces, where expanding toolsets necessitates hierarchical retrieval strategies. Crucially, our approach underscores the potential of training-free architectural engineering, achieving state-of-the-art performance on CURE-Bench without the need for expensive end-to-end finetuning. This provides a scalable, agile foundation for the next generation of trustworthy AI-driven therapeutics. Code has been released on https://github.com/June01/CureAgent.

  • 2 authors
·
Dec 4, 2025

Triad: Vision Foundation Model for 3D Magnetic Resonance Imaging

Vision foundation models (VFMs) are pre-trained on extensive image datasets to learn general representations for diverse types of data. These models can subsequently be fine-tuned for specific downstream tasks, significantly boosting performance across a broad range of applications. However, existing vision foundation models that claim to be applicable to various clinical tasks are mostly pre-trained on 3D computed tomography (CT), which benefits from the availability of extensive 3D CT databases. Significant differences between CT and magnetic resonance imaging (MRI) in imaging principles, signal characteristics, and data distribution may hinder their practical performance and versatility in MRI-specific applications. Here, we propose Triad, a vision foundation model for 3D MRI. Triad adopts a widely used autoencoder architecture to learn robust representations from 131,170 3D MRI volumes and uses organ-independent imaging descriptions to constrain the semantic distribution of the visual modality. The above pre-training dataset is called Triad-131K, which is currently the largest 3D MRI pre-training dataset. We evaluate Triad across three tasks, namely, organ/tumor segmentation, organ/cancer classification, and medical image registration, in two data modalities (within-domain and out-of-domain) settings using 25 downstream datasets. By initializing models with Triad's pre-trained weights, nnUNet-Triad improves segmentation performance by 2.51% compared to nnUNet-Scratch across 17 datasets. Swin-B-Triad achieves a 3.97% improvement over Swin-B-Scratch in classification tasks across five datasets. SwinUNETR-Triad improves by 4.00% compared to SwinUNETR-Scratch in registration tasks across two datasets. Our study demonstrates that pre-training can improve performance when the data modalities and organs of upstream and downstream tasks are consistent.

  • 8 authors
·
Feb 22, 2025

CheXagent: Towards a Foundation Model for Chest X-Ray Interpretation

Chest X-rays (CXRs) are the most frequently performed imaging test in clinical practice. Recent advances in the development of vision-language foundation models (FMs) give rise to the possibility of performing automated CXR interpretation, which can assist physicians with clinical decision-making and improve patient outcomes. However, developing FMs that can accurately interpret CXRs is challenging due to the (1) limited availability of large-scale vision-language datasets in the medical image domain, (2) lack of vision and language encoders that can capture the complexities of medical data, and (3) absence of evaluation frameworks for benchmarking the abilities of FMs on CXR interpretation. In this work, we address these challenges by first introducing CheXinstruct - a large-scale instruction-tuning dataset curated from 28 publicly-available datasets. We then present CheXagent - an instruction-tuned FM capable of analyzing and summarizing CXRs. To build CheXagent, we design a clinical large language model (LLM) for parsing radiology reports, a vision encoder for representing CXR images, and a network to bridge the vision and language modalities. Finally, we introduce CheXbench - a novel benchmark designed to systematically evaluate FMs across 8 clinically-relevant CXR interpretation tasks. Extensive quantitative evaluations and qualitative reviews with five expert radiologists demonstrate that CheXagent outperforms previously-developed general- and medical-domain FMs on CheXbench tasks. Furthermore, in an effort to improve model transparency, we perform a fairness evaluation across factors of sex, race and age to highlight potential performance disparities. Our project is at https://stanford-aimi.github.io/chexagent.html.

  • 17 authors
·
Jan 22, 2024 2

Derm1M: A Million-scale Vision-Language Dataset Aligned with Clinical Ontology Knowledge for Dermatology

The emergence of vision-language models has transformed medical AI, enabling unprecedented advances in diagnostic capability and clinical applications. However, progress in dermatology has lagged behind other medical domains due to the lack of standard image-text pairs. Existing dermatological datasets are limited in both scale and depth, offering only single-label annotations across a narrow range of diseases instead of rich textual descriptions, and lacking the crucial clinical context needed for real-world applications. To address these limitations, we present Derm1M, the first large-scale vision-language dataset for dermatology, comprising 1,029,761 image-text pairs. Built from diverse educational resources and structured around a standard ontology collaboratively developed by experts, Derm1M provides comprehensive coverage for over 390 skin conditions across four hierarchical levels and 130 clinical concepts with rich contextual information such as medical history, symptoms, and skin tone. To demonstrate Derm1M potential in advancing both AI research and clinical application, we pretrained a series of CLIP-like models, collectively called DermLIP, on this dataset. The DermLIP family significantly outperforms state-of-the-art foundation models on eight diverse datasets across multiple tasks, including zero-shot skin disease classification, clinical and artifacts concept identification, few-shot/full-shot learning, and cross-modal retrieval. Our dataset and code will be public.

Monash Monash University
·
Mar 19, 2025 2

EXAONE Path 2.5: Pathology Foundation Model with Multi-Omics Alignment

Cancer progression arises from interactions across multiple biological layers, especially beyond morphological and across molecular layers that remain invisible to image-only models. To capture this broader biological landscape, we present EXAONE Path 2.5, a pathology foundation model that jointly models histologic, genomic, epigenetic and transcriptomic modalities, producing an integrated patient representation that reflects tumor biology more comprehensively. Our approach incorporates three key components: (1) multimodal SigLIP loss enabling all-pairwise contrastive learning across heterogeneous modalities, (2) a fragment-aware rotary positional encoding (F-RoPE) module that preserves spatial structure and tissue-fragment topology in WSI, and (3) domain-specialized internal foundation models for both WSI and RNA-seq to provide biologically grounded embeddings for robust multimodal alignment. We evaluate EXAONE Path 2.5 against six leading pathology foundation models across two complementary benchmarks: an internal real-world clinical dataset and the Patho-Bench benchmark covering 80 tasks. Our framework demonstrates high data and parameter efficiency, achieving on-par performance with state-of-the-art foundation models on Patho-Bench while exhibiting the highest adaptability in the internal clinical setting. These results highlight the value of biologically informed multimodal design and underscore the potential of integrated genotype-to-phenotype modeling for next-generation precision oncology.

  • 7 authors
·
Dec 15, 2025

A Foundation Model for Wearable Movement Data in Mental Health Research

Wearable movement data is collected by nearly all commercially available smartwatches and is a valuable resource for mental health research, reflecting fine-grained temporal behavioral trends. Despite its promise, the development of foundation models for health wearable modeling remains limited when compared to clinical image and text analysis. We designed transformers with patch embeddings and used self-supervised masked autoencoder pretraining on minute-level week-long actigraphy (physical activity intensity measurement) sequences to develop and evaluate the Pretrained Actigraphy Transformer (PAT). PAT is an open-source foundation model for wearable movement time series that combines week-long temporal modeling, psychiatric outcome evaluation, and reproducibility on public data. Pretrained on data from 21,538 U.S. participants in a nationally representative cohort from the National Health and Nutrition Examination Survey (NHANES), PAT consistently outperformed non-foundation-model baselines across mental health prediction tasks-including benzodiazepine and SSRI use, depression, and sleep abnormalities. During the benzodiazepine medication usage prediction task, PAT demonstrated the largest improvement over non-foundational deep learning models commonly used for time-series modeling (i.e., 55.6% improvement over the LSTM, 21.4% improvement over the 1-D CNN, 14.8% improvement over the ConvLSTM). Beyond predictive accuracy, PAT provides interpretable attention maps highlighting specific periods of daily activity most important for clinical predictions, offering model transparency and potential clinical insights. The results suggest that PAT offers an easy-to-deploy, adaptable and scalable solution to advance clinical insight from wearable sensor data for researchers and clinicians. GitHub: https://github.com/njacobsonlab/Pretrained-Actigraphy-Transformer/

  • 5 authors
·
May 29

FEMBA on the Edge: Physiologically-Aware Pre-Training, Quantization, and Deployment of a Bidirectional Mamba EEG Foundation Model on an Ultra-low Power Microcontroller

Objective: To enable continuous, long-term neuro-monitoring on wearable devices by overcoming the computational bottlenecks of Transformer-based Electroencephalography (EEG) foundation models and the quantization challenges inherent to State-Space Models (SSMs). Methods: We present FEMBA, a bidirectional Mamba architecture pre-trained on over 21,000 hours of EEG. We introduce a novel Physiologically-Aware pre-training objective, consisting of a reconstruction with low-pass filtering, to prioritize neural oscillations over high-frequency artifacts. To address the activation outliers common in SSMs, we employ Quantization-Aware Training (QAT) to compress the model to 2-bit weights. The framework is deployed on a parallel ultra-low-power RISC-V microcontroller (GAP9) using a custom double-buffered memory streaming scheme. Results: The proposed low-pass pre-training improves downstream AUROC on TUAB from 0.863 to 0.893 and AUPR from 0.862 to 0.898 compared to the best contrastive baseline. QAT successfully compresses weights with negligible performance loss, whereas standard post-training quantization degrades accuracy by approximately 30\%. The embedded implementation achieves deterministic real-time inference (1.70~s per 5~s window) and reduces the memory footprint by 74\% (to approx2~MB), achieving competitive accuracy with up to 27times fewer FLOPs than Transformer benchmarks. Conclusion: FEMBA demonstrates that Mamba-based foundation models can be effectively quantized and deployed on extreme-edge hardware without sacrificing the representation quality required for robust clinical analysis. Significance: This work establishes the first full-stack framework for deploying large-scale EEG foundation models on ultra-low-power wearables, facilitating continuous, SSM based monitoring for epilepsy and sleep disorders.

  • 6 authors
·
Mar 17

OrthoDiffusion: A Generalizable Multi-Task Diffusion Foundation Model for Musculoskeletal MRI Interpretation

Musculoskeletal disorders represent a significant global health burden and are a leading cause of disability worldwide. While MRI is essential for accurate diagnosis, its interpretation remains exceptionally challenging. Radiologists must identify multiple potential abnormalities within complex anatomical structures across different imaging planes, a process that requires significant expertise and is prone to variability. We developed OrthoDiffusion, a unified diffusion-based foundation model designed for multi-task musculoskeletal MRI interpretation. The framework utilizes three orientation-specific 3D diffusion models, pre-trained in a self-supervised manner on 15,948 unlabeled knee MRI scans, to learn robust anatomical features from sagittal, coronal, and axial views. These view-specific representations are integrated to support diverse clinical tasks, including anatomical segmentation and multi-label diagnosis. Our evaluation demonstrates that OrthoDiffusion achieves excellent performance in the segmentation of 11 knee structures and the detection of 8 knee abnormalities. The model exhibited remarkable robustness across different clinical centers and MRI field strengths, consistently outperforming traditional supervised models. Notably, in settings where labeled data was scarce, OrthoDiffusion maintained high diagnostic precision using only 10\% of training labels. Furthermore, the anatomical representations learned from knee imaging proved highly transferable to other joints, achieving strong diagnostic performance across 11 diseases of the ankle and shoulder. These findings suggest that diffusion-based foundation models can serve as a unified platform for multi-disease diagnosis and anatomical segmentation, potentially improving the efficiency and accuracy of musculoskeletal MRI interpretation in real-world clinical workflows.

  • 11 authors
·
Feb 23

A texture-based framework for foundational ultrasound models

Ultrasound is the most widely used medical imaging modality, yet the images it produces are fundamentally unique, arising from tissue-dependent scattering, reflection, and speed-of-sound variations that produce a constrained set of characteristic textures that differ markedly from natural-image statistics. These acoustically driven patterns make ultrasound challenging for algorithms originally designed for natural images. To bridge this gap, the field has increasingly turned to foundation models, hoping to leverage their generalization capabilities. However, these models often falter in ultrasound applications because they are not designed for ultrasound physics, they are merely trained on ultrasound data. Therefore, it is essential to integrate ultrasound-specific domain knowledge into established learning frameworks. We achieve this by reformulating self-supervised learning as a texture-analysis problem, introducing texture ultrasound semantic analysis (TUSA). Using TUSA, models learn to leverage highly scalable contrastive methods to extract true domain-specific representations directly from simple B-mode images. We train a TUSA model on a combination of open-source, simulated, and in vivo data. The latent space is compared to several larger foundation models, demonstrating that our approach gives TUSA models better generalizability for difficult downstream tasks on unique online datasets as well as a clinical eye dataset collected for this study. Our model achieves higher accuracy in detecting COVID (70%), spinal hematoma (100%) and vitreous hemorrhage (97%) and correlates more closely with quantitative parameters like liver steatosis (r = 0.83), ejection fraction (r = 0.63), and oxygen saturation (r = 0.38). We open-source the model weights and training script: https://github.com/talg2324/tusa

  • 3 authors
·
Jan 31

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

Progress in AI-based retinal image analysis has advanced with foundation models, yet evaluating their reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging analysis, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark for evaluating retinal fundus models that considers vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted through supervised fine-tuning with low-rank adaptation (LoRA). Results show that no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. These findings demonstrate that retinal model evaluation is inherently multidimensional. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards

  • 7 authors
·
Sep 26

PRISM2: Unlocking Multi-Modal General Pathology AI with Clinical Dialogue

Recent rapid progress in the field of computational pathology has been enabled by foundation models. These models are beginning to move beyond encoding image patches towards whole-slide understanding but their clinical utility remains limited. In this work, we present PRISM2, a multimodal slide-level foundation model trained on data from 700,000 diagnostic specimen-report pairs, the largest vision (2.3 million whole slide images) and language (14M question-answer pairs) histopathology dataset to date. By learning through clinical-dialogue supervision, PRISM2 aligns histomorphologic features with the language of diagnostic reasoning, producing slide-level representations that support both direct diagnostic question-answering and transferable embeddings for downstream tasks. Without additional training, PRISM2 matches or exceeds the cancer-detection performance of clinical-grade products. This is observed without loss of generality on other tasks, where PRISM2 achieves top performance. Finally, using survival prediction as the example, we show that task-specific finetuning with a large dataset can outperform task-specific models, further improving performance. These results demonstrate how language-supervised pretraining provides a scalable, clinically grounded signal for learning generalizable pathology representations, bridging human diagnostic reasoning and foundation-model performance.

  • 19 authors
·
Oct 30, 2025

A Disease-Centric Vision-Language Foundation Model for Precision Oncology in Kidney Cancer

The non-invasive assessment of increasingly incidentally discovered renal masses is a critical challenge in urologic oncology, where diagnostic uncertainty frequently leads to the overtreatment of benign or indolent tumors. In this study, we developed and validated RenalCLIP using a dataset of 27,866 CT scans from 8,809 patients across nine Chinese medical centers and the public TCIA cohort, a visual-language foundation model for characterization, diagnosis and prognosis of renal mass. The model was developed via a two-stage pre-training strategy that first enhances the image and text encoders with domain-specific knowledge before aligning them through a contrastive learning objective, to create robust representations for superior generalization and diagnostic precision. RenalCLIP achieved better performance and superior generalizability across 10 core tasks spanning the full clinical workflow of kidney cancer, including anatomical assessment, diagnostic classification, and survival prediction, compared with other state-of-the-art general-purpose CT foundation models. Especially, for complicated task like recurrence-free survival prediction in the TCIA cohort, RenalCLIP achieved a C-index of 0.726, representing a substantial improvement of approximately 20% over the leading baselines. Furthermore, RenalCLIP's pre-training imparted remarkable data efficiency; in the diagnostic classification task, it only needs 20% training data to achieve the peak performance of all baseline models even after they were fully fine-tuned on 100% of the data. Additionally, it achieved superior performance in report generation, image-text retrieval and zero-shot diagnosis tasks. Our findings establish that RenalCLIP provides a robust tool with the potential to enhance diagnostic accuracy, refine prognostic stratification, and personalize the management of patients with kidney cancer.

  • 20 authors
·
Aug 22, 2025

Towards Context-Aware Clinical Motion Understanding in Daily Living at Home: Freezing of Gait Detection with Egocentric Vision

Understanding motion in daily living requires context beyond kinematics, because similar inertial patterns during activities of daily living (ADLs) can reflect intentional stopping, object interaction, or pathological movement impairment. Egocentric vision provides task-related context that may help disambiguate these cases. We investigate this challenge through freezing of gait (FOG) detection in Parkinson's disease (PD), a symptom strongly influenced by contextual factors during ADLs. Using synchronized egocentric video, wearable IMUs, and expert-annotated FOG labels collected from 13 PD participants in their homes, we evaluate frozen representations from pretrained ego-video and time-series foundation models, alongside an IMU-based TCN trained from scratch, under leave-one-subject-out evaluation. The IMU-based TCN achieved the strongest event-detection performance, reaching 42.3 F1 and 83.0 AUROC, compared with 32.6 F1 and 77.2 AUROC for V-JEPA2 ego-video features. Although ego-video alone did not outperform IMU-based sensing, it showed above-chance discrimination, and qualitative analyses suggest that egocentric vision may capture FOG-relevant information independent of IMUs. Together, these results support the use of pretrained ego-video representations to add contextual information to wearable-sensor-based clinical motion understanding in daily living.

  • 8 authors
·
Aug 12

A Multimodal Knowledge-enhanced Whole-slide Pathology Foundation Model

Remarkable strides in computational pathology have been made in the task-agnostic foundation model that advances the performance of a wide array of downstream clinical tasks. Despite the promising performance, there are still several challenges. First, prior works have resorted to either vision-only or image-caption data, disregarding pathology reports with more clinically authentic information from pathologists and gene expression profiles which respectively offer distinct knowledge for versatile clinical applications. Second, the current progress in pathology FMs predominantly concentrates on the patch level, where the restricted context of patch-level pretraining fails to capture whole-slide patterns. Even recent slide-level FMs still struggle to provide whole-slide context for patch representation. In this study, for the first time, we develop a pathology foundation model incorporating three levels of modalities: pathology slides, pathology reports, and gene expression data, which resulted in 26,169 slide-level modality pairs from 10,275 patients across 32 cancer types, amounting to over 116 million pathological patch images. To leverage these data for CPath, we propose a novel whole-slide pretraining paradigm that injects the multimodal whole-slide context into the patch representation, called Multimodal Self-TAught PRetraining (mSTAR). The proposed paradigm revolutionizes the pretraining workflow for CPath, enabling the pathology FM to acquire the whole-slide context. To the best of our knowledge, this is the first attempt to incorporate three modalities at the whole-slide context for enhancing pathology FMs. To systematically evaluate the capabilities of mSTAR, we built the largest spectrum of oncological benchmark, spanning 7 categories of oncological applications in 15 types of 97 practical oncological tasks.

  • 19 authors
·
Jul 22, 2024

Loud or Silent? A Reusable Framework for Per-Modality Failure Analysis in Multimodal Clinical AI

Multimodal clinical models are usually judged on accuracy with every modality present, but deployment removes modalities; an echocardiogram is often unavailable where an ECG is routine. Two questions then matter beyond the size of the accuracy loss: which modality was responsible, and whether the model fails loudly or silently once that modality is dropped. The distinction is per-example and modality-level, and is separate from post-hoc feature attribution (e.g. SHAP). Models are replaced often; the evaluation that answers these questions is reused. We present a model-agnostic modality-failure framework: given N modality embeddings, any mask-aware probe, and labels, it returns a per-example failure taxonomy, a per-modality complementarity matrix that attributes error to modalities, and a loud-vs-silent dropout profile separating monitorable failures from those that pass unflagged far from the decision boundary, using only deployment-observable signals. We release it as a small, unit-tested harness and validate it against planted ground truth. Across seeds it recovers that planted modality dominance and complementary subset, reports per-modality loud-vs-silent rates, and scales to a three-modality complementarity matrix; because the planted structure is known by construction, this validates recovery of per-example attribution rather than clinical performance. We then instantiate the framework on frozen EchoJEPA and HuBERT-ECG embeddings for LVEF and the EF <= 40% HFrEF gate over a paired MIMIC-IV cohort, where on the held-out test split (n = 245) dropping echo nearly doubles error. The narrow echo-to-ECG overlap that bounds cohort size is itself a deployment finding for cardiac foundation models. All of our work can be found at https://github.com/criticaldata/PRIMED-AI.

CT-$Δ$Bench: A Benchmark for Longitudinal 3D Medical Imaging Difference Reporting with Vision-Language Models

In medical imaging, the clinical value of Computed Tomography (CT) lies not only in depicting current disease status, but crucially in enabling longitudinal comparison of serial scans to determine disease evolution, a process that underpins response assessment, recurrence detection, and ongoing patient management. Yet, despite this central role of temporal comparison in clinical decision-making, existing medical foundation models remain largely confined to single-study understanding, leaving temporally grounded cross-examination insufficiently addressed. To address this gap, we study longitudinal imaging difference reporting, a task in which a model takes two temporally separated scans from the same patient and generates a clinically meaningful report describing interval changes between them. We introduce CT-ΔBench, a dedicated benchmark for this task with patient-level splitting to prevent information leakage. To better evaluate this task beyond surface-level text similarity, we further develop change-aware metrics specifically designed to capture clinically meaningful longitudinal changes, and conduct an independent physician validation to assess the reliability of the synthesized references and event extraction pipeline. We also compare direct paired-CT reasoning with an indirect two-stage pipeline that first generates single-timepoint reports and then performs textual differencing. Finally, we propose DeltaMed, a baseline model for direct paired-CT difference reporting, and train it on the benchmark training set. Together, these contributions lay the groundwork for temporally aware medical foundation models that better reflect real-world longitudinal clinical reasoning.

  • 4 authors
·
Aug 11

Project Imaging-X: A Survey of 1000+ Open-Access Medical Imaging Datasets for Foundation Model Development

Foundation models have demonstrated remarkable success across diverse domains and tasks, primarily due to the thrive of large-scale, diverse, and high-quality datasets. However, in the field of medical imaging, the curation and assembling of such medical datasets are highly challenging due to the reliance on clinical expertise and strict ethical and privacy constraints, resulting in a scarcity of large-scale unified medical datasets and hindering the development of powerful medical foundation models. In this work, we present the largest survey to date of medical image datasets, covering over 1,000 open-access datasets with a systematic catalog of their modalities, tasks, anatomies, annotations, limitations, and potential for integration. Our analysis exposes a landscape that is modest in scale, fragmented across narrowly scoped tasks, and unevenly distributed across organs and modalities, which in turn limits the utility of existing medical image datasets for developing versatile and robust medical foundation models. To turn fragmentation into scale, we propose a metadata-driven fusion paradigm (MDFP) that integrates public datasets with shared modalities or tasks, thereby transforming multiple small data silos into larger, more coherent resources. Building on MDFP, we release an interactive discovery portal that enables end-to-end, automated medical image dataset integration, and compile all surveyed datasets into a unified, structured table that clearly summarizes their key characteristics and provides reference links, offering the community an accessible and comprehensive repository. By charting the current terrain and offering a principled path to dataset consolidation, our survey provides a practical roadmap for scaling medical imaging corpora, supporting faster data discovery, more principled dataset creation, and more capable medical foundation models.

Discrete Neural Interlingua for Ontology-Agnostic EHR Modeling

EHR foundation models promise scalable clinical prediction across health systems, yet their deployment is constrained by a tokenization bottleneck. The same clinical concept can appear as different ontology codes, local identifiers, synonyms, or free-text descriptions, which standard EHR tokenizers treat as unrelated symbols. A model trained on MIMIC-III with a closed-vocabulary tokenizer can use only 13% of eICU events. We introduce MEDIATOR, a discrete ontology-agnostic tokenizer that maps any clinical concept expressed as text into a shared vector-quantized codebook, turning EHR harmonization into open-vocabulary tokenization without manual mappings or a fixed vocabulary. Trained with synonym supervision and guided by enriched concept descriptions, code co-occurrence, and relation graphs, MEDIATOR collapses equivalent expressions while organizing distinct concepts in a medically meaningful discrete space. Used as the token interface of an EHR Transformer, MEDIATOR improves mean AUPRC over the strongest prior tokenizer by 4.0 points (8% relative) on 20 MIMIC-III tasks and by 8.6 points (29% relative) in zero-shot transfer to 14 eICU tasks, where it uses all events. The transfer gain combines coverage and representation, as MEDIATOR remains the best tokenizer under identical inputs (+1.0 and +1.9 points on operational and subcohort-mortality tasks). Same-encoder controls show that the text encoder drives in-domain accuracy, while the learned objectives of MEDIATOR drive transfer robustness and entity-linking quality. MEDIATOR also enables transferable attribution across hospitals.

  • 9 authors
·
Oct 18

From Given to Gathered Evidence: Agentic Learning for Longitudinal Medical Reasoning

Foundation models can serve as clinical agents through tool-use harnesses. However, conventional medical benchmarks assess reasoning over preselected evidence rather than the ability to seek it across clinical records and longitudinal imaging. We propose CASE: a series of role-specific Clinical Agents for Seeking Evidence, together with a tool-use harness and an agentic post-training framework for compact vision-language policy models. We further introduce a longitudinal multimodal benchmark built on UK Biobank, comprising 50,401 clinical questions derived from real-world ICD-10-coded diagnoses of 4,739 participants. Each question links to a patient-specific environment containing clinical context and multi-sequence MRI from baseline and follow-up visits, where agents autonomously select which visits, organs, modalities, slices, and specialist tools to inspect and compare. Supervised fine-tuning transfers evidence-seeking workflows from 14,734 frontier-model interaction trajectories, followed by agentic reinforcement learning on the learner's own environment interactions. Privileged on-policy self-distillation and rubric-based LLM feedback refine evidence-to-conclusion reasoning without prescribing tool sequences. Experiments show that CASE moves beyond question-answer imitation toward transferable investigation policies, strengthening evidence-grounded longitudinal reasoning. Under matched evaluation conditions, our Qwen3-VL-8B based agent achieves over 16% and 10% relative improvements in answer accuracy over GPT-5.4 and Claude Opus 4.8. Code will be available at https://github.com/VinyehShaw/CASE.

CASE-Bench CASE
·
Sep 29 2

Phikon-v2, A large and public feature extractor for biomarker prediction

Gathering histopathology slides from over 100 publicly available cohorts, we compile a diverse dataset of 460 million pathology tiles covering more than 30 cancer sites. Using this dataset, we train a large self-supervised vision transformer using DINOv2 and publicly release one iteration of this model for further experimentation, coined Phikon-v2. While trained on publicly available histology slides, Phikon-v2 surpasses our previously released model (Phikon) and performs on par with other histopathology foundation models (FM) trained on proprietary data. Our benchmarks include eight slide-level tasks with results reported on external validation cohorts avoiding any data contamination between pre-training and evaluation datasets. Our downstream training procedure follows a simple yet robust ensembling strategy yielding a +1.75 AUC increase across tasks and models compared to one-shot retraining (p<0.001). We compare Phikon (ViT-B) and Phikon-v2 (ViT-L) against 14 different histology feature extractors, making our evaluation the most comprehensive to date. Our result support evidences that DINOv2 handles joint model and data scaling better than iBOT. Also, we show that recent scaling efforts are overall beneficial to downstream performance in the context of biomarker prediction with GigaPath and H-Optimus-0 (two ViT-g with 1.1B parameters each) standing out. However, the statistical margins between the latest top-performing FMs remain mostly non-significant; some even underperform on specific indications or tasks such as MSI prediction - deposed by a 13x smaller model developed internally. While latest foundation models may exhibit limitations for clinical deployment, they nonetheless offer excellent grounds for the development of more specialized and cost-efficient histology encoders fueling AI-guided diagnostic tools.

  • 4 authors
·
Sep 13, 2024

PathMoE: Interpretable Multimodal Interaction Experts for Pediatric Brain Tumor Classification

Accurate classification of pediatric central nervous system tumors remains challenging due to histological complexity and limited training data. While pathology foundation models have advanced whole-slide image (WSI) analysis, they often fail to leverage the rich, complementary information found in clinical text and tissue microarchitecture. To this end, we propose PathMoE, an interpretable multimodal framework that integrates H\&E slides, pathology reports, and nuclei-level cell graphs via an interaction-aware mixture-of-experts architecture built on state-of-the-art foundation models for each modality. By training specialized experts to capture modality uniqueness, redundancy, and synergy, PathMoE employs an input-dependent gating mechanism that dynamically weights these interactions, providing sample-level interpretability. We evaluate our framework on two dataset-specific classification tasks on an internal pediatric brain tumor dataset (PBT) and external TCGA datasets. PathMoE improves macro-F1 from 0.762 to 0.799 (+0.037) on PBT when integrating WSI, text, and graph modalities; on TCGA, augmenting WSI with graph knowledge improves macro-F1 from 0.668 to 0.709 (+0.041). These results demonstrate significant performance gains over state-of-the-art image-only baselines while revealing the specific modality interactions driving individual predictions. This interpretability is particularly critical for rare tumor subtypes, where transparent model reasoning is essential for clinical trust and diagnostic validation.

  • 13 authors
·
Mar 1

Dolphin v1.0 Technical Report

Ultrasound is crucial in modern medicine but faces challenges like operator dependence, image noise, and real-time scanning, hindering AI integration. While large multimodal models excel in other medical imaging areas, they struggle with ultrasound's complexities. To address this, we introduce Dolphin v1.0 (V1) and its reasoning-augmented version, Dolphin R1-the first large-scale multimodal ultrasound foundation models unifying diverse clinical tasks in a single vision-language framework.To tackle ultrasound variability and noise, we curated a 2-million-scale multimodal dataset, combining textbook knowledge, public data, synthetic samples, and general corpora. This ensures robust perception, generalization, and clinical adaptability.The Dolphin series employs a three-stage training strategy: domain-specialized pretraining, instruction-driven alignment, and reinforcement-based refinement. Dolphin v1.0 delivers reliable performance in classification, detection, regression, and report generation. Dolphin R1 enhances diagnostic inference, reasoning transparency, and interpretability through reinforcement learning with ultrasound-specific rewards.Evaluated on U2-Bench across eight ultrasound tasks, Dolphin R1 achieves a U2-score of 0.5835-over twice the second-best model (0.2968) setting a new state of the art. Dolphin v1.0 also performs competitively, validating the unified framework. Comparisons show reasoning-enhanced training significantly improves diagnostic accuracy, consistency, and interpretability, highlighting its importance for high-stakes medical AI.

  • 19 authors
·
Sep 30, 2025 1

LuMamba: Latent Unified Mamba for Electrode Topology-Invariant and Efficient EEG Modeling

Electroencephalography (EEG) enables non-invasive monitoring of brain activity across clinical and neurotechnology applications, yet building foundation models for EEG remains challenging due to differing electrode topologies and computational scalability, as Transformer architectures incur quadratic sequence complexity. As a joint solution, we propose LuMamba (Latent Unified Mamba), a self-supervised framework combining topology-invariant encodings with linear-complexity state-space modeling, using LUNA's learned-query cross-attention mechanism for channel unification~luna, and FEMBA's bidirectional Mamba blocks for efficient temporal modeling~femba. Within this architecture, we provide the first systematic investigation of the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA) for biosignal learning. Pre-trained on over 21,000 hours of unlabeled EEG from the TUEG corpus, LuMamba is evaluated on five downstream tasks spanning abnormality detection, artifact recognition, and mental condition classification across electrode configurations ranging from 16 to 26 channels. In the pre-training objective, masked reconstruction alone yields structured but less generalizable representations, while LeJEPA alone produces diffuse embeddings; combining both objectives achieves the most robust performance. With only 4.6M parameters, LuMamba attains 80.99\% balanced accuracy on TUAB and achieves state-of-art performance on Alzheimer's detection (0.97 AUPR), while requiring 377times fewer FLOPS than state-of-art models at equivalent sequence lengths and scaling to 12times longer sequences before reaching typical GPU memory limits. Code is available at https://github.com/pulp-bio/biofoundation

TRACE: Grounding Time Series in Context for Multimodal Embedding and Retrieval

The ubiquity of dynamic data in domains such as weather, healthcare, and energy underscores a growing need for effective interpretation and retrieval of time-series data. These data are inherently tied to domain-specific contexts, such as clinical notes or weather narratives, making cross-modal retrieval essential not only for downstream tasks but also for developing robust time-series foundation models by retrieval-augmented generation (RAG). Despite the increasing demand, time-series retrieval remains largely underexplored. Existing methods often lack semantic grounding, struggle to align heterogeneous modalities, and have limited capacity for handling multi-channel signals. To address this gap, we propose TRACE, a generic multimodal retriever that grounds time-series embeddings in aligned textual context. TRACE enables fine-grained channel-level alignment and employs hard negative mining to facilitate semantically meaningful retrieval. It supports flexible cross-modal retrieval modes, including Text-to-Timeseries and Timeseries-to-Text, effectively linking linguistic descriptions with complex temporal patterns. By retrieving semantically relevant pairs, TRACE enriches downstream models with informative context, leading to improved predictive accuracy and interpretability. Beyond a static retrieval engine, TRACE also serves as a powerful standalone encoder, with lightweight task-specific tuning that refines context-aware representations while maintaining strong cross-modal alignment. These representations achieve state-of-the-art performance on downstream forecasting and classification tasks. Extensive experiments across multiple domains highlight its dual utility, as both an effective encoder for downstream applications and a general-purpose retriever to enhance time-series models.

  • 8 authors
·
Jun 10, 2025

Neural Codecs as Biosignal Tokenizers

Neurophysiological recordings such as electroencephalography (EEG) offer accessible and minimally invasive means of estimating physiological activity for applications in healthcare, diagnostic screening, and even immersive entertainment. However, these recordings yield high-dimensional, noisy time-series data that typically require extensive pre-processing and handcrafted feature extraction to reveal meaningful information. Recently, there has been a surge of interest in applying representation learning techniques from large pre-trained (foundation) models to effectively decode and interpret biosignals. We discuss the challenges posed for incorporating such methods and introduce BioCodec, an alternative representation learning framework inspired by neural codecs to capture low-level signal characteristics in the form of discrete tokens. Pre-trained on thousands of EEG hours, BioCodec shows efficacy across multiple downstream tasks, ranging from clinical diagnostic tasks and sleep physiology to decoding speech and motor imagery, particularly in low-resource settings. Additionally, we provide a qualitative analysis of codebook usage and estimate the spatial coherence of codebook embeddings from EEG connectivity. Notably, we also document the suitability of our method to other biosignal data, i.e., electromyographic (EMG) signals. Overall, the proposed approach provides a versatile solution for biosignal tokenization that performs competitively with state-of-the-art models. The source code and model checkpoints are shared.

  • 7 authors
·
Oct 10, 2025

Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation

Vision-grounded medical report generation aims to produce clinically accurate descriptions of medical images, anchored in explicit visual evidence to improve interpretability and facilitate integration into clinical workflows. However, existing methods often rely on separately trained detection modules that require extensive expert annotations, introducing high labeling costs and limiting generalizability due to pathology distribution bias across datasets. To address these challenges, we propose Self-Supervised Anatomical Consistency Learning (SS-ACL) -- a novel and annotation-free framework that aligns generated reports with corresponding anatomical regions using simple textual prompts. SS-ACL constructs a hierarchical anatomical graph inspired by the invariant top-down inclusion structure of human anatomy, organizing entities by spatial location. It recursively reconstructs fine-grained anatomical regions to enforce intra-sample spatial alignment, inherently guiding attention maps toward visually relevant areas prompted by text. To further enhance inter-sample semantic alignment for abnormality recognition, SS-ACL introduces a region-level contrastive learning based on anatomical consistency. These aligned embeddings serve as priors for report generation, enabling attention maps to provide interpretable visual evidence. Extensive experiments demonstrate that SS-ACL, without relying on expert annotations, (i) generates accurate and visually grounded reports -- outperforming state-of-the-art methods by 10\% in lexical accuracy and 25\% in clinical efficacy, and (ii) achieves competitive performance on various downstream visual tasks, surpassing current leading visual foundation models by 8\% in zero-shot visual grounding.

  • 6 authors
·
Sep 30, 2025

SegMoTE: Token-Level Mixture of Experts for Medical Image Segmentation

Medical image segmentation is vital for clinical diagnosis and quantitative analysis, yet remains challenging due to the heterogeneity of imaging modalities and the high cost of pixel-level annotations. Although general interactive segmentation models like SAM have achieved remarkable progress, their transfer to medical imaging still faces two key bottlenecks: (i) the lack of adaptive mechanisms for modality- and anatomy-specific tasks, which limits generalization in out-of-distribution medical scenarios; and (ii) current medical adaptation methods fine-tune on large, heterogeneous datasets without selection, leading to noisy supervision, higher cost, and negative transfer. To address these issues, we propose SegMoTE, an efficient and adaptive framework for medical image segmentation. SegMoTE preserves SAM's original prompt interface, efficient inference, and zero-shot generalization while introducing only a small number of learnable parameters to dynamically adapt across modalities and tasks. In addition, we design a progressive prompt tokenization mechanism that enables fully automatic segmentation, significantly reducing annotation dependence. Trained on MedSeg-HQ, a curated dataset less than 1% of existing large-scale datasets, SegMoTE achieves SOTA performance across diverse imaging modalities and anatomical tasks. It represents the first efficient, robust, and scalable adaptation of general segmentation models to the medical domain under extremely low annotation cost, advancing the practical deployment of foundation vision models in clinical applications.

  • 8 authors
·
Feb 21

Me LLaMA: Foundation Large Language Models for Medical Applications

Recent large language models (LLMs) such as ChatGPT and LLaMA have shown great promise in many AI applications. However, their performance on medical tasks is suboptimal and can be improved by training on extensive domain-specific datasets. This study introduces Me LLaMA, a medical LLM family that includes foundation models - Me LLaMA 13/70B, along with their chat-enhanced versions - Me LLaMA 13/70B-chat, developed through continual pre-training and instruction tuning of LLaMA2 using large medical datasets. Our domain-specific data suite for training and evaluation includes a large-scale, continual pre-training dataset with 129B tokens, an instruction tuning dataset with 214k samples, and a new medical evaluation benchmark (MIBE) across six tasks with 12 datasets. Our extensive evaluation using the MIBE shows that Me LLaMA models achieve overall better performance than existing open-source medical LLMs in zero-shot, few-shot and supervised learning abilities. Their zero-shot performance is comparable with ChatGPT across 7 out of 8 datasets, with a slight variance of within 3%, and yet falls short when compared to GPT-4. In addition, we investigated the catastrophic forgetting problem, and our results show that Me LLaMA models outperform other open-source medical LLMs in mitigating this issue. Me LLaMA is one of the largest open-source medical foundation LLMs that use both biomedical and clinical data. It exhibits superior performance across both general and medical tasks compared to other open-source medical LLMs, rendering it an attractive choice for medical AI applications. We release our models, datasets, and evaluation scripts at: https://github.com/BIDS-Xu-Lab/Me-LLaMA.

  • 16 authors
·
Feb 20, 2024

BrainWave: A Brain Signal Foundation Model for Clinical Applications

Neural electrical activity is fundamental to brain function, underlying a range of cognitive and behavioral processes, including movement, perception, decision-making, and consciousness. Abnormal patterns of neural signaling often indicate the presence of underlying brain diseases. The variability among individuals, the diverse array of clinical symptoms from various brain disorders, and the limited availability of diagnostic classifications, have posed significant barriers to formulating reliable model of neural signals for diverse application contexts. Here, we present BrainWave, the first foundation model for both invasive and non-invasive neural recordings, pretrained on more than 40,000 hours of electrical brain recordings (13.79 TB of data) from approximately 16,000 individuals. Our analysis show that BrainWave outperforms all other competing models and consistently achieves state-of-the-art performance in the diagnosis and identification of neurological disorders. We also demonstrate robust capabilities of BrainWave in enabling zero-shot transfer learning across varying recording conditions and brain diseases, as well as few-shot classification without fine-tuning, suggesting that BrainWave learns highly generalizable representations of neural signals. We hence believe that open-sourcing BrainWave will facilitate a wide range of clinical applications in medicine, paving the way for AI-driven approaches to investigate brain disorders and advance neuroscience research.

  • 7 authors
·
Sep 28

Specialist vision-language models for clinical ophthalmology

Clinicians spend a significant amount of time reviewing medical images and transcribing their findings regarding patient diagnosis, referral and treatment in text form. Vision-language models (VLMs), which automatically interpret images and summarize their findings as text, have enormous potential to alleviate clinical workloads and increase patient access to high-quality medical care. While foundational models have stirred considerable interest in the medical community, it is unclear whether their general capabilities translate to real-world clinical utility. In this work, we show that foundation VLMs markedly underperform compared to practicing ophthalmologists on specialist tasks crucial to the care of patients with age-related macular degeneration (AMD). To address this, we initially identified the essential capabilities required for image-based clinical decision-making, and then developed a curriculum to selectively train VLMs in these skills. The resulting model, RetinaVLM, can be instructed to write reports that significantly outperform those written by leading foundation medical VLMs in disease staging (F1 score of 0.63 vs. 0.11) and patient referral (0.67 vs. 0.39), and approaches the diagnostic performance of junior ophthalmologists (who achieve 0.77 and 0.78 on the respective tasks). Furthermore, in a reader study involving two senior ophthalmologists with up to 32 years of experience, RetinaVLM's reports were found to be similarly correct (78.6% vs. 82.1%) and complete (both 78.6%) as reports written by junior ophthalmologists with up to 10 years of experience. These results demonstrate that our curriculum-based approach provides a blueprint for specializing generalist foundation medical VLMs to handle real-world clinical tasks.

  • 16 authors
·
Jul 11, 2024