new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 6

Label-Wording Augmentation in a Typed-Decision Encoder: Gains on Unfamiliar Words, Not on Abbreviations or Codes

Typed-decision models score options that the caller supplies at request time, so their accuracy depends on label wording that the model's developer does not control. We compare two releases of a 307M-parameter multilingual cross-encoder, Ru-Jev, trained on thirteen Russian-language tasks; the later release adds an augmentation that presents labels in several surface forms. Holding questions fixed and varying only how eighteen routing labels are worded, we evaluate ten label vocabularies, produced by three separate processes and checked for overlap with the training data, with five candidates per question and, for eight of them, also with eighteen. On held-out vocabularies made of ordinary or borrowed words (English-derived jargon, office slang, department names), the augmented release is more accurate in every setting, by up to 0.24. Eleven of these fourteen gains survive a Holm correction (slang with eighteen candidates and descriptive sentences with five do not), and for jargon on all labels the label-level interval excludes zero in both settings. On abbreviations and opaque codes it gives no usable gain: on abbreviations it is not better, and worse on the clean slice, and on opaque codes both releases stay at or below chance once labels related to training options are removed. In most cells where accuracy rises, the risk-coverage area falls, but with eighteen candidates confident errors rise on jargon and slang. On two datasets neither release saw, accuracy moves by -8.4 and +5.6 points. We also report four evaluation hazards from comparing the two releases.

  • 1 authors
·
Nov 4

SliceBridge: context-consistent repair of corrupted slice intervals in T1-weighted MRI

Structural magnetic resonance imaging (MRI) images are sometimes corrupted over a contiguous set of slices, where acquisition, motion, hardware, or reconstruction effects leave a single slice or short interval inconsistent with its neighbors while the rest of the image remains usable. Such localized corruption can bias downstream morphometric analysis, yet discarding or reacquiring an otherwise usable image is costly. We formulate this as an image restoration problem: given the location of the affected interval, reconstruct those slices from the surrounding anatomical and imaging context. We propose SliceBridge, a framework for restoring corrupted slice intervals in T1-weighted MRI using rectified flow matching conditioned on the surrounding intact slices and their relative slice positions. Through-plane consistency is encouraged by coupling the slices within the interval through interval-correlated initial noise, a shared flow time, and synchronized sampling. The restored interval is then inserted back, leaving all other slices unchanged. We trained and validated the model on 9,877 T1-weighted brain MRI volumes from four datasets and evaluated it on 581 external subjects using clean interval withholding and controlled corruptions. Compared with a matched model that reconstructed target slices independently, SliceBridge reduced error in slice-to-slice changes within repaired intervals by 32.9%-41.3% across interval lengths and achieved higher SSIM at every interval length. In controlled-corruption cases, SliceBridge reduced the median error in regional brain volume estimates produced by a downstream segmentation model from 1.95% in corrupted volumes to 1.05%.