new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Nov 9

DeWave: Discrete EEG Waves Encoding for Brain Dynamics to Text Translation

The translation of brain dynamics into natural language is pivotal for brain-computer interfaces (BCIs). With the swift advancement of large language models, such as ChatGPT, the need to bridge the gap between the brain and languages becomes increasingly pressing. Current methods, however, require eye-tracking fixations or event markers to segment brain dynamics into word-level features, which can restrict the practical application of these systems. To tackle these issues, we introduce a novel framework, DeWave, that integrates discrete encoding sequences into open-vocabulary EEG-to-text translation tasks. DeWave uses a quantized variational encoder to derive discrete codex encoding and align it with pre-trained language models. This discrete codex representation brings forth two advantages: 1) it realizes translation on raw waves without marker by introducing text-EEG contrastive alignment training, and 2) it alleviates the interference caused by individual differences in EEG waves through an invariant discrete codex with or without markers. Our model surpasses the previous baseline (40.1 and 31.7) by 3.06% and 6.34%, respectively, achieving 41.35 BLEU-1 and 33.71 Rouge-F on the ZuCo Dataset. This work is the first to facilitate the translation of entire EEG signal periods without word-level order markers (e.g., eye fixations), scoring 20.5 BLEU-1 and 29.5 Rouge-1 on the ZuCo Dataset.

  • 5 authors
·
Sep 25, 2023

EEG2Rep: Enhancing Self-supervised EEG Representation Through Informative Masked Inputs

Self-supervised approaches for electroencephalography (EEG) representation learning face three specific challenges inherent to EEG data: (1) The low signal-to-noise ratio which challenges the quality of the representation learned, (2) The wide range of amplitudes from very small to relatively large due to factors such as the inter-subject variability, risks the models to be dominated by higher amplitude ranges, and (3) The absence of explicit segmentation in the continuous-valued sequences which can result in less informative representations. To address these challenges, we introduce EEG2Rep, a self-prediction approach for self-supervised representation learning from EEG. Two core novel components of EEG2Rep are as follows: 1) Instead of learning to predict the masked input from raw EEG, EEG2Rep learns to predict masked input in latent representation space, and 2) Instead of conventional masking methods, EEG2Rep uses a new semantic subsequence preserving (SSP) method which provides informative masked inputs to guide EEG2Rep to generate rich semantic representations. In experiments on 6 diverse EEG tasks with subject variability, EEG2Rep significantly outperforms state-of-the-art methods. We show that our semantic subsequence preserving improves the existing masking methods in self-prediction literature and find that preserving 50\% of EEG recordings will result in the most accurate results on all 6 tasks on average. Finally, we show that EEG2Rep is robust to noise addressing a significant challenge that exists in EEG data. Models and code are available at:https://github.com/Navidfoumani/EEG2Rep

  • 6 authors
·
Jun 17, 2024

A Simple Review of EEG Foundation Models: Datasets, Advancements and Future Perspectives

Electroencephalogram (EEG) signals play a crucial role in understanding brain activity and diagnosing neurological diseases. Because supervised EEG encoders are unable to learn robust EEG patterns and rely too heavily on expensive signal annotation, research has turned to general-purpose self-supervised EEG encoders, known as EEG-based models (EEG-FMs), to achieve robust and scalable EEG feature extraction. However, the readiness of early EEG-FMs for practical applications and the standards for long-term research progress remain unclear. Therefore, a systematic and comprehensive review of first-generation EEG-FMs is necessary to understand their current state-of-the-art and identify key directions for future EEG-FMs. To this end, this study reviews 14 early EEG-FMs and provides a critical comprehensive analysis of their methodologies, empirical findings, and unaddressed research gaps. This review focuses on the latest developments in EEG-based models (EEG-FMs), which have shown great potential for processing and analyzing EEG data. We discuss various EEG-FMs, including their architectures, pretraining strategies, pretraining and downstream datasets, and other details. This review also highlights challenges and future directions in the field, aiming to provide a comprehensive overview for researchers and practitioners interested in EEG analysis and related EEG-FM.

  • 4 authors
·
Apr 24, 2025

Boundary-Aware Context Grounding for A Low-Channel EEG Agent

Large language models (LLMs) can make scientific software easier to use. However, a general model does not automatically know which measurements a particular sensor can support, which algorithms are implemented in the current software, or which conclusions are justified by a computed result. These distinctions are especially important for low-channel electroencephalography (EEG), where sparse spatial coverage and variable signal quality make plausible but unsupported interpretations easy to produce. We present NeuraDock Agent, an open-source architecture that separates a deterministic local EEG engine from a hardware-aware language layer. The numerical engine parses recordings, performs quality control, executes reviewed spectral workflows, and writes machine-readable artifacts. The LLM receives only a compact, allowlisted summary and a versioned context pack. The context describes the seven-channel hardware, reviewed workflows, result fields, implementation boundaries, scientific limits, and reference cases. Raw EEG and dense per-sample arrays remain local We evaluate the system at three levels. First, 12 recordings produced identical structured results over ten numerical repetitions, and a complete Rest/Task run produced identical result, report, and figure hashes over three repetitions. Second, request-capture and failure-injection experiments confirmed the tested data boundary and preservation of local artifacts under HTTP, malformed-output, and connection failures. Third, a boundary-awareness benchmark tested 36 ordinary and adversarial questions under four context ablations and two LLMs, yielding 288 outputs.These results support hardware- and implementation-aware grounding as a practical mechanism for calibrating what an EEG agent accepts, qualifies, or refuses; they do not establish clinical validity or a validated absolute cognitive-load index.

  • 4 authors
·
Jun 24 2

Self-supervised EEG Representation Learning for Automatic Sleep Staging

Background: Deep learning models have shown great success in automating tasks in sleep medicine by learning from carefully annotated Electroencephalogram (EEG) data. However, effectively utilizing a large amount of raw EEG remains a challenge. Objective: In this paper, we aim to learn robust vector representations from massive unlabeled EEG signals, such that the learned vectorized features (1) are expressive enough to replace the raw signals in the sleep staging task; and (2) provide better predictive performance than supervised models in scenarios of fewer labels and noisy samples. Methods: We propose a self-supervised model, named Contrast with the World Representation (ContraWR), for EEG signal representation learning, which uses global statistics from the dataset to distinguish signals associated with different sleep stages. The ContraWR model is evaluated on three real-world EEG datasets that include both at-home and in-lab EEG recording settings. Results: ContraWR outperforms 4 recent self-supervised learning methods on the sleep staging task across 3 large EEG datasets. ContraWR also beats supervised learning when fewer training labels are available (e.g., 4% accuracy improvement when less than 2% data is labeled). Moreover, the model provides informative representative feature structures in 2D projection. Conclusions: We show that ContraWR is robust to noise and can provide high-quality EEG representations for downstream prediction tasks. The proposed model can be generalized to other unsupervised physiological signal learning tasks. Future directions include exploring task-specific data augmentations and combining self-supervised with supervised methods, building upon the initial success of self-supervised learning in this paper.

  • 4 authors
·
Feb 11, 2023

Large Brain Model for Learning Generic Representations with Tremendous EEG Data in BCI

The current electroencephalogram (EEG) based deep learning models are typically designed for specific datasets and applications in brain-computer interaction (BCI), limiting the scale of the models and thus diminishing their perceptual capabilities and generalizability. Recently, Large Language Models (LLMs) have achieved unprecedented success in text processing, prompting us to explore the capabilities of Large EEG Models (LEMs). We hope that LEMs can break through the limitations of different task types of EEG datasets, and obtain universal perceptual capabilities of EEG signals through unsupervised pre-training. Then the models can be fine-tuned for different downstream tasks. However, compared to text data, the volume of EEG datasets is generally small and the format varies widely. For example, there can be mismatched numbers of electrodes, unequal length data samples, varied task designs, and low signal-to-noise ratio. To overcome these challenges, we propose a unified foundation model for EEG called Large Brain Model (LaBraM). LaBraM enables cross-dataset learning by segmenting the EEG signals into EEG channel patches. Vector-quantized neural spectrum prediction is used to train a semantically rich neural tokenizer that encodes continuous raw EEG channel patches into compact neural codes. We then pre-train neural Transformers by predicting the original neural codes for the masked EEG channel patches. The LaBraMs were pre-trained on about 2,500 hours of various types of EEG signals from around 20 datasets and validated on multiple different types of downstream tasks. Experiments on abnormal detection, event type classification, emotion recognition, and gait prediction show that our LaBraM outperforms all compared SOTA methods in their respective fields. Our code is available at https://github.com/935963004/LaBraM.

  • 3 authors
·
May 28, 2024

Neural Codecs as Biosignal Tokenizers

Neurophysiological recordings such as electroencephalography (EEG) offer accessible and minimally invasive means of estimating physiological activity for applications in healthcare, diagnostic screening, and even immersive entertainment. However, these recordings yield high-dimensional, noisy time-series data that typically require extensive pre-processing and handcrafted feature extraction to reveal meaningful information. Recently, there has been a surge of interest in applying representation learning techniques from large pre-trained (foundation) models to effectively decode and interpret biosignals. We discuss the challenges posed for incorporating such methods and introduce BioCodec, an alternative representation learning framework inspired by neural codecs to capture low-level signal characteristics in the form of discrete tokens. Pre-trained on thousands of EEG hours, BioCodec shows efficacy across multiple downstream tasks, ranging from clinical diagnostic tasks and sleep physiology to decoding speech and motor imagery, particularly in low-resource settings. Additionally, we provide a qualitative analysis of codebook usage and estimate the spatial coherence of codebook embeddings from EEG connectivity. Notably, we also document the suitability of our method to other biosignal data, i.e., electromyographic (EMG) signals. Overall, the proposed approach provides a versatile solution for biosignal tokenization that performs competitively with state-of-the-art models. The source code and model checkpoints are shared.

  • 7 authors
·
Oct 10, 2025

hvEEGNet: exploiting hierarchical VAEs on EEG data for neuroscience applications

With the recent success of artificial intelligence in neuroscience, a number of deep learning (DL) models were proposed for classification, anomaly detection, and pattern recognition tasks in electroencephalography (EEG). EEG is a multi-channel time-series that provides information about the individual brain activity for diagnostics, neuro-rehabilitation, and other applications (including emotions recognition). Two main issues challenge the existing DL-based modeling methods for EEG: the high variability between subjects and the low signal-to-noise ratio making it difficult to ensure a good quality in the EEG data. In this paper, we propose two variational autoencoder models, namely vEEGNet-ver3 and hvEEGNet, to target the problem of high-fidelity EEG reconstruction. We properly designed their architectures using the blocks of the well-known EEGNet as the encoder, and proposed a loss function based on dynamic time warping. We tested the models on the public Dataset 2a - BCI Competition IV, where EEG was collected from 9 subjects and 22 channels. hvEEGNet was found to reconstruct the EEG data with very high-fidelity, outperforming most previous solutions (including our vEEGNet-ver3 ). Furthermore, this was consistent across all subjects. Interestingly, hvEEGNet made it possible to discover that this popular dataset includes a number of corrupted EEG recordings that might have influenced previous literature results. We also investigated the training behaviour of our models and related it with the quality and the size of the input EEG dataset, aiming at opening a new research debate on this relationship. In the future, hvEEGNet could be used as anomaly (e.g., artefact) detector in large EEG datasets to support the domain experts, but also the latent representations it provides could be used in other classification problems and EEG data generation.

  • 4 authors
·
Nov 20, 2023

Scaling Law in Neural Data: Non-Invasive Speech Decoding with 175 Hours of EEG Data

Brain-computer interfaces (BCIs) hold great potential for aiding individuals with speech impairments. Utilizing electroencephalography (EEG) to decode speech is particularly promising due to its non-invasive nature. However, recordings are typically short, and the high variability in EEG data has led researchers to focus on classification tasks with a few dozen classes. To assess its practical applicability for speech neuroprostheses, we investigate the relationship between the size of EEG data and decoding accuracy in the open vocabulary setting. We collected extensive EEG data from a single participant (175 hours) and conducted zero-shot speech segment classification using self-supervised representation learning. The model trained on the entire dataset achieved a top-1 accuracy of 48\% and a top-10 accuracy of 76\%, while mitigating the effects of myopotential artifacts. Conversely, when the data was limited to the typical amount used in practice (sim10 hours), the top-1 accuracy dropped to 2.5\%, revealing a significant scaling effect. Additionally, as the amount of training data increased, the EEG latent representation progressively exhibited clearer temporal structures of spoken phrases. This indicates that the decoder can recognize speech segments in a data-driven manner without explicit measurements of word recognition. This research marks a significant step towards the practical realization of EEG-based speech BCIs.

  • 6 authors
·
Jul 9, 2024

Multimodal LLMs Can Learn to Read Brain Signals: A Vision--Language Model for Unified Multi-Task EEG Decoding

Learning EEG representations that generalize across cognitive tasks, subjects, and recording conditions remains a key challenge in electroencephalography (EEG) decoding. Recent advances in foundation models have improved EEG decoding performance, yet a fundamental open question remains: how to effectively interface neural signals with these models to enable multi-task learning across datasets. To investigate this question, we introduce BraVista, a visual-language framework that encodes multichannel EEG signals as structured images and enables multi-task learning through instruction-conditioned vision-language models (VLMs). Our approach relies on continued post-training of a general-domain VLM, leveraging its visual and linguistic priors to adapt to neural signals without a separate large-scale EEG-specific pretraining stage. We evaluate BraVista on four datasets spanning sleep staging, emotion recognition, cognitive workload classification, and abnormal EEG detection, showing strong performance across these tasks. Further analyses show that the choice of EEG-to-image representation is critical to performance. Moreover, through controlled perturbations of the EEG signal, we observe a gradual performance degradation under increasing noise, suggesting that the model relies on EEG-relevant information rather than superficial visual patterns. Together, these findings establish structured visual representations as an effective and scalable interface between neural signals and general-domain foundation models for unified multi-task EEG decoding.

  • 3 authors
·
Oct 6

Laya: A LeJEPA Approach to EEG via Latent Prediction over Reconstruction

Electroencephalography (EEG) is a widely used tool for studying brain function, with applications in clinical neuroscience, diagnosis, and brain-computer interfaces (BCIs). Recent EEG foundation models trained on large unlabeled corpora aim to learn transferable representations, but their effectiveness remains unclear; reported improvements over smaller task-specific models are often modest, sensitive to downstream adaptation and fine-tuning strategies, and limited under linear probing. We hypothesize that one contributing factor is the reliance on signal reconstruction as the primary self-supervised learning (SSL) objective, which biases representations toward high-variance artifacts rather than task-relevant neural structure. To address this limitation, we explore an SSL paradigm based on Joint Embedding Predictive Architectures (JEPA), which learn by predicting latent representations instead of reconstructing raw signals. We introduce Laya, the first EEG foundation model based on LeJEPA. We show that latent prediction yields representations that encode semantic structure in EEG: Laya embeddings track clinically meaningful state changes such as seizure onset, are resilient to noise, and achieve the strongest mean clinical accuracy under frozen linear probing, with particular gains on tasks where relevant neural patterns are subtle and easily obscured by artifacts. Controlled ablations against matched MAE variants confirm that the choice of pretraining objective, rather than architecture or data, is the primary driver of these gains.

  • 5 authors
·
May 6

BrainBench: Benchmarking Large Language Models for Comprehensive EEG Understanding

Electroencephalography (EEG) analysis extends beyond assigning predefined labels to recordings; it requires workflows connecting natural-language instructions, signal processing, quantitative evidence, and scientific interpretation. We term this capability comprehensive EEG understanding. Existing evaluations, however, primarily target isolated decoding tasks or system-specific demonstrations, leaving the competence of large language models (LLMs) insufficiently quantified. We introduce , a unified benchmark for comprehensive, instruction-conditioned EEG understanding. It comprises four subsets---Foundational Analysis, Sleep Assessment, Neurocognitive Assessment, and Physiological Integration---covering 17 datasets, tasks, and over real-data instances. Given an instruction and EEG recordings with optional physiological signals, a system must perform the analysis and produce a scientifically grounded report and, when required, artifacts. Outputs are assessed through numerical, categorical, set, sequence, semantic, and artifact validation. We evaluate representative LLMs across more than 100K executions under two paradigms: autonomous code execution with CodeAct and structured agentic analysis with BrainAgent. Results vary substantially across models, subsets, difficulty levels, and execution paradigms, showing that EEG competence depends on the model and its operationalization. provides a reproducible testbed for advancing LLM-based EEG understanding. The code and benchmark will be released soon, with evaluation results continuously updated.

  • 7 authors
·
Aug 3

EEGDM: EEG Representation Learning via Generative Diffusion Model

While electroencephalogram (EEG) has been a crucial tool for monitoring the brain and diagnosing neurological disorders (e.g., epilepsy), learning meaningful representations from raw EEG signals remains challenging due to limited annotations and high signal variability. Recently, EEG foundation models (FMs) have shown promising potential by adopting transformer architectures and self-supervised pre-training methods from large language models (e.g., masked prediction) to learn representations from diverse EEG data, followed by fine-tuning on specific EEG tasks. Nonetheless, these large models often incurred high computational costs during both training and inference, with only marginal performance improvements as model size increases. In this work, we proposed EEG representation learning framework building upon Generative Diffusion Model (EEGDM). Specifically, we developed structured state-space model for diffusion pretraining (SSMDP) to better capture the temporal dynamics of EEG signals and trained the architecture using a Denoising Diffusion Probabilistic Model. The resulting latent EEG representations were then used for downstream classification tasks via our proposed latent fusion transformer (LFT). To evaluate our method, we used the multi-event Temple University EEG Event Corpus and compared EEGDM with current state-of-the-art approaches, including EEG FMs. Empirical results showed that our method outperformed existing methods while being approximately 19x more lightweight. These findings suggested that EEGDM offered a promising alternative to current FMs. Our code is available at: https://github.com/jhpuah/EEGDM.

  • 8 authors
·
Aug 13, 2025

Visual Decoding and Reconstruction via EEG Embeddings with Guided Diffusion

How to decode human vision through neural signals has attracted a long-standing interest in neuroscience and machine learning. Modern contrastive learning and generative models improved the performance of fMRI-based visual decoding and reconstruction. However, the high cost and low temporal resolution of fMRI limit their applications in brain-computer interfaces (BCIs), prompting a high need for EEG-based visual reconstruction. In this study, we present an EEG-based visual reconstruction framework. It consists of a plug-and-play EEG encoder called the Adaptive Thinking Mapper (ATM), which is aligned with image embeddings, and a two-stage EEG guidance image generator that first transforms EEG features into image priors and then reconstructs the visual stimuli with a pre-trained image generator. Our approach allows EEG embeddings to achieve superior performance in image classification and retrieval tasks. Our two-stage image generation strategy vividly reconstructs images seen by humans. Furthermore, we analyzed the impact of signals from different time windows and brain regions on decoding and reconstruction. The versatility of our framework is demonstrated in the magnetoencephalogram (MEG) data modality. We report that EEG-based visual decoding achieves SOTA performance, highlighting the portability, low cost, and high temporal resolution of EEG, enabling a wide range of BCI applications. The code of ATM is available at https://github.com/dongyangli-del/EEG_Image_decode.

  • 5 authors
·
Mar 12, 2024

Benchmarking ERP Analysis: Manual Features, Deep Learning, and Foundation Models

Event-related potential (ERP), a specialized paradigm of electroencephalographic (EEG), reflects neurological responses to external stimuli or events, generally associated with the brain's processing of specific cognitive tasks. ERP plays a critical role in cognitive analysis, the detection of neurological diseases, and the assessment of psychological states. Recent years have seen substantial advances in deep learning-based methods for spontaneous EEG and other non-time-locked task-related EEG signals. However, their effectiveness on ERP data remains underexplored, and many existing ERP studies still rely heavily on manually extracted features. In this paper, we conduct a comprehensive benchmark study that systematically compares traditional manual features (followed by a linear classifier), deep learning models, and pre-trained EEG foundation models for ERP analysis. We establish a unified data preprocessing and training pipeline and evaluate these approaches on two representative tasks, ERP stimulus classification and ERP-based brain disease detection, across 12 publicly available datasets. Furthermore, we investigate various patch-embedding strategies within advanced Transformer architectures to identify embedding designs that better suit ERP data. Our study provides a landmark framework to guide method selection and tailored model design for future ERP analysis. The code is available at https://github.com/DL4mHealth/ERP-Benchmark.

  • 5 authors
·
Jan 2

CLARA: Clinical Report Auto-completion

Generating clinical reports from raw recordings such as X-rays and electroencephalogram (EEG) is an essential and routine task for doctors. However, it is often time-consuming to write accurate and detailed reports. Most existing methods try to generate the whole reports from the raw input with limited success because 1) generated reports often contain errors that need manual review and correction, 2) it does not save time when doctors want to write additional information into the report, and 3) the generated reports are not customized based on individual doctors' preference. We propose {\it CL}inic{\it A}l {\it R}eport {\it A}uto-completion (CLARA), an interactive method that generates reports in a sentence by sentence fashion based on doctors' anchor words and partially completed sentences. CLARA searches for most relevant sentences from existing reports as the template for the current report. The retrieved sentences are sequentially modified by combining with the input feature representations to create the final report. In our experimental evaluation, CLARA achieved 0.393 CIDEr and 0.248 BLEU-4 on X-ray reports and 0.482 CIDEr and 0.491 BLEU-4 for EEG reports for sentence-level generation, which is up to 35% improvement over the best baseline. Also via our qualitative evaluation, CLARA is shown to produce reports which have a significantly higher level of approval by doctors in a user study (3.74 out of 5 for CLARA vs 2.52 out of 5 for the baseline).

  • 5 authors
·
Feb 26, 2020

Classification of BCI-EEG based on augmented covariance matrix

Objective: Electroencephalography signals are recorded as a multidimensional dataset. We propose a new framework based on the augmented covariance extracted from an autoregressive model to improve motor imagery classification. Methods: From the autoregressive model can be derived the Yule-Walker equations, which show the emergence of a symmetric positive definite matrix: the augmented covariance matrix. The state-of the art for classifying covariance matrices is based on Riemannian Geometry. A fairly natural idea is therefore to extend the standard approach using these augmented covariance matrices. The methodology for creating the augmented covariance matrix shows a natural connection with the delay embedding theorem proposed by Takens for dynamical systems. Such an embedding method is based on the knowledge of two parameters: the delay and the embedding dimension, respectively related to the lag and the order of the autoregressive model. This approach provides new methods to compute the hyper-parameters in addition to standard grid search. Results: The augmented covariance matrix performed noticeably better than any state-of-the-art methods. We will test our approach on several datasets and several subjects using the MOABB framework, using both within-session and cross-session evaluation. Conclusion: The improvement in results is due to the fact that the augmented covariance matrix incorporates not only spatial but also temporal information, incorporating nonlinear components of the signal through an embedding procedure, which allows the leveraging of dynamical systems algorithms. Significance: These results extend the concepts and the results of the Riemannian distance based classification algorithm.

  • 2 authors
·
Feb 9, 2023

From Video to EEG: Adapting Joint Embedding Predictive Architecture to Uncover Visual Concepts in Brain Signal Analysis

EEG signals capture brain activity with high temporal and low spatial resolution, supporting applications such as neurological diagnosis, cognitive monitoring, and brain-computer interfaces. However, effective analysis is hindered by limited labeled data, high dimensionality, and the absence of scalable models that fully capture spatiotemporal dependencies. Existing self-supervised learning (SSL) methods often focus on either spatial or temporal features, leading to suboptimal representations. To this end, we propose EEG-VJEPA, a novel adaptation of the Video Joint Embedding Predictive Architecture (V-JEPA) for EEG classification. By treating EEG as video-like sequences, EEG-VJEPA learns semantically meaningful spatiotemporal representations using joint embeddings and adaptive masking. To our knowledge, this is the first work that exploits V-JEPA for EEG classification and explores the visual concepts learned by the model. Evaluations on the publicly available Temple University Hospital (TUH) Abnormal EEG dataset show that EEG-VJEPA outperforms existing state-of-the-art models in classification accuracy. Beyond classification accuracy, EEG-VJEPA captures physiologically relevant spatial and temporal signal patterns, offering interpretable embeddings that may support human-AI collaboration in diagnostic workflows. These findings position EEG-VJEPA as a promising framework for scalable, trustworthy EEG analysis in real-world clinical settings.

  • 6 authors
·
Jul 4, 2025

LuMamba: Latent Unified Mamba for Electrode Topology-Invariant and Efficient EEG Modeling

Electroencephalography (EEG) enables non-invasive monitoring of brain activity across clinical and neurotechnology applications, yet building foundation models for EEG remains challenging due to differing electrode topologies and computational scalability, as Transformer architectures incur quadratic sequence complexity. As a joint solution, we propose LuMamba (Latent Unified Mamba), a self-supervised framework combining topology-invariant encodings with linear-complexity state-space modeling, using LUNA's learned-query cross-attention mechanism for channel unification~luna, and FEMBA's bidirectional Mamba blocks for efficient temporal modeling~femba. Within this architecture, we provide the first systematic investigation of the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA) for biosignal learning. Pre-trained on over 21,000 hours of unlabeled EEG from the TUEG corpus, LuMamba is evaluated on five downstream tasks spanning abnormality detection, artifact recognition, and mental condition classification across electrode configurations ranging from 16 to 26 channels. In the pre-training objective, masked reconstruction alone yields structured but less generalizable representations, while LeJEPA alone produces diffuse embeddings; combining both objectives achieves the most robust performance. With only 4.6M parameters, LuMamba attains 80.99\% balanced accuracy on TUAB and achieves state-of-art performance on Alzheimer's detection (0.97 AUPR), while requiring 377times fewer FLOPS than state-of-art models at equivalent sequence lengths and scaling to 12times longer sequences before reaching typical GPU memory limits. Code is available at https://github.com/pulp-bio/biofoundation

BIOT: Cross-data Biosignal Learning in the Wild

Biological signals, such as electroencephalograms (EEG), play a crucial role in numerous clinical applications, exhibiting diverse data formats and quality profiles. Current deep learning models for biosignals are typically specialized for specific datasets and clinical settings, limiting their broader applicability. Motivated by the success of large language models in text processing, we explore the development of foundational models that are trained from multiple data sources and can be fine-tuned on different downstream biosignal tasks. To overcome the unique challenges associated with biosignals of various formats, such as mismatched channels, variable sample lengths, and prevalent missing values, we propose a Biosignal Transformer (\method). The proposed \method model can enable cross-data learning with mismatched channels, variable lengths, and missing values by tokenizing diverse biosignals into unified "biosignal sentences". Specifically, we tokenize each channel into fixed-length segments containing local signal features, flattening them to form consistent "sentences". Channel embeddings and {\em relative} position embeddings are added to preserve spatio-temporal features. The \method model is versatile and applicable to various biosignal learning settings across different datasets, including joint pre-training for larger models. Comprehensive evaluations on EEG, electrocardiogram (ECG), and human activity sensory signals demonstrate that \method outperforms robust baselines in common settings and facilitates learning across multiple datasets with different formats. Use CHB-MIT seizure detection task as an example, our vanilla \method model shows 3\% improvement over baselines in balanced accuracy, and the pre-trained \method models (optimized from other data sources) can further bring up to 4\% improvements.

  • 3 authors
·
May 9, 2023

Enhancing Epileptic Seizure Detection with EEG Feature Embeddings

Epilepsy is one of the most prevalent brain disorders that disrupts the lives of millions worldwide. For patients with drug-resistant seizures, there exist implantable devices capable of monitoring neural activity, promptly triggering neurostimulation to regulate seizures, or alerting patients of potential episodes. Next-generation seizure detection systems heavily rely on high-accuracy machine learning-based classifiers to detect the seizure onset. Here, we propose to enhance the seizure detection performance by learning informative embeddings of the EEG signal. We empirically demonstrate, for the first time, that converting raw EEG signals to appropriate embeddings can significantly boost the performance of seizure detection algorithms. Importantly, we show that embedding features, which converts the raw EEG into an alternative representation, is beneficial for various machine learning models such as Logistic Regression, Multi-Layer Perceptron, Support Vector Machines, and Gradient Boosted Trees. The experiments were conducted on the CHB-MIT scalp EEG dataset. With the proposed EEG feature embeddings, we achieve significant improvements in sensitivity, specificity, and AUC score across multiple models. By employing this approach alongside an SVM classifier, we were able to attain state-of-the-art classification performance with a sensitivity of 100% and specificity of 99%, setting a new benchmark in the field.

  • 3 authors
·
Oct 28, 2023

REVE: A Foundation Model for EEG -- Adapting to Any Setup with Large-Scale Pretraining on 25,000 Subjects

Foundation models have transformed AI by reducing reliance on task-specific data through large-scale pretraining. While successful in language and vision, their adoption in EEG has lagged due to the heterogeneity of public datasets, which are collected under varying protocols, devices, and electrode configurations. Existing EEG foundation models struggle to generalize across these variations, often restricting pretraining to a single setup, resulting in suboptimal performance, in particular under linear probing. We present REVE (Representation for EEG with Versatile Embeddings), a pretrained model explicitly designed to generalize across diverse EEG signals. REVE introduces a novel 4D positional encoding scheme that enables it to process signals of arbitrary length and electrode arrangement. Using a masked autoencoding objective, we pretrain REVE on over 60,000 hours of EEG data from 92 datasets spanning 25,000 subjects, representing the largest EEG pretraining effort to date. REVE achieves state-of-the-art results on 10 downstream EEG tasks, including motor imagery classification, seizure detection, sleep staging, cognitive load estimation, and emotion recognition. With little to no fine-tuning, it demonstrates strong generalization, and nuanced spatio-temporal modeling. We release code, pretrained weights, and tutorials to support standardized EEG research and accelerate progress in clinical neuroscience.

  • 8 authors
·
Oct 24, 2025

Alljoined-1.6M: A Million-Trial EEG-Image Dataset for Evaluating Affordable Brain-Computer Interfaces

We present a new large-scale electroencephalography (EEG) dataset as part of the THINGS initiative, comprising over 1.6 million visual stimulus trials collected from 20 participants, and totaling more than twice the size of the most popular current benchmark dataset, THINGS-EEG2. Crucially, our data was recorded using a 32-channel consumer-grade wet electrode system costing ~$2.2k, around 27x cheaper than research-grade EEG systems typically used in cognitive neuroscience labs. Our work is one of the first open-source, large-scale EEG resource designed to closely reflect the quality of hardware that is practical to deploy in real-world, downstream applications of brain-computer interfaces (BCIs). We aim to explore the specific question of whether deep neural network-based BCI research and semantic decoding methods can be effectively conducted with such affordable systems, filling an important gap in current literature that is extremely relevant for future research. In our analysis, we not only demonstrate that decoding of high-level semantic information from EEG of visualized images is possible at consumer-grade hardware, but also that our data can facilitate effective EEG-to-Image reconstruction even despite significantly lower signal-to-noise ratios. In addition to traditional benchmarks, we also conduct analyses of EEG-to-Image models that demonstrate log-linear decoding performance with increasing data volume on our data, and discuss the trade-offs between hardware cost, signal fidelity, and the scale of data collection efforts in increasing the size and utility of currently available datasets. Our contributions aim to pave the way for large-scale, cost-effective EEG research with widely accessible equipment, and position our dataset as a unique resource for the democratization and development of effective deep neural models of visual cognition.

  • 8 authors
·
Aug 25, 2025

EEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces

Brain computer interfaces (BCI) enable direct communication with a computer, using neural activity as the control signal. This neural signal is generally chosen from a variety of well-studied electroencephalogram (EEG) signals. For a given BCI paradigm, feature extractors and classifiers are tailored to the distinct characteristics of its expected EEG control signal, limiting its application to that specific signal. Convolutional Neural Networks (CNNs), which have been used in computer vision and speech recognition, have successfully been applied to EEG-based BCIs; however, they have mainly been applied to single BCI paradigms and thus it remains unclear how these architectures generalize to other paradigms. Here, we ask if we can design a single CNN architecture to accurately classify EEG signals from different BCI paradigms, while simultaneously being as compact as possible. In this work we introduce EEGNet, a compact convolutional network for EEG-based BCIs. We introduce the use of depthwise and separable convolutions to construct an EEG-specific model which encapsulates well-known EEG feature extraction concepts for BCI. We compare EEGNet to current state-of-the-art approaches across four BCI paradigms: P300 visual-evoked potentials, error-related negativity responses (ERN), movement-related cortical potentials (MRCP), and sensory motor rhythms (SMR). We show that EEGNet generalizes across paradigms better than the reference algorithms when only limited training data is available. We demonstrate three different approaches to visualize the contents of a trained EEGNet model to enable interpretation of the learned features. Our results suggest that EEGNet is robust enough to learn a wide variety of interpretable features over a range of BCI tasks, suggesting that the observed performances were not due to artifact or noise sources in the data.

  • 6 authors
·
May 15, 2018

DIVER-1: Scaling Intracranial EEG Foundation Models for Transferable Representations

Intracranial EEG (iEEG) provides direct, millisecond-scale recordings of human neural activity, but reusable representation learning is difficult because electrode layouts, anatomical coverage, referencing schemes, and recording conditions vary across patients and centers. We introduce DIVER-1, a self-supervised iEEG foundation model for variable-input recordings that combines any-variate electrode-time attention, spatio-temporal resampling, input-conditioned positional embeddings, and multi-domain masked reconstruction without assuming a fixed electrode montage. We pretrain two variants, DIVER-1-0.1s and DIVER-1-1s, on 5,310 hours of ECoG and SEEG spanning 352k channel-hours, roughly 54x the BrainTreeBank-based pretraining volume. We evaluate DIVER-1 on two held-out benchmarks: Neuroprobe for naturalistic cognitive decoding and MAYO for seizure detection. On leakage-aware Neuroprobe, DIVER-1-0.1s outperforms prior evaluated iEEG foundation models despite using no BrainTreeBank recordings, the corpus underlying Neuroprobe, during pretraining; it also exceeds the linear spectrogram decoder in mean AUROC and remains competitive with stronger nonlinear baselines, a level prior evaluated iEEG foundation models did not reach. DIVER-1-1s also achieves the top AUROC on MAYO seizure detection. Finally, we conduct, to our knowledge, the first controlled compute-aware scaling study for self-supervised iEEG pretraining, sweeping data scale, subject count, training duration, and model size up to 1.8B parameters. Our results indicate a data-constrained regime: expanding unique recordings and training sufficiently long are more reliable scaling axes than increasing parameter count alone. Code is available at link.

  • 13 authors
·
May 22

EEG Foundation Challenge: From Cross-Task to Cross-Subject EEG Decoding

Current electroencephalogram (EEG) decoding models are typically trained on small numbers of subjects performing a single task. Here, we introduce a large-scale, code-submission-based competition comprising two challenges. First, the Transfer Challenge asks participants to build and test a model that can zero-shot decode new tasks and new subjects from their EEG data. Second, the Psychopathology factor prediction Challenge asks participants to infer subject measures of mental health from EEG data. For this, we use an unprecedented, multi-terabyte dataset of high-density EEG signals (128 channels) recorded from over 3,000 child to young adult subjects engaged in multiple active and passive tasks. We provide several tunable neural network baselines for each of these two challenges, including a simple network and demographic-based regression models. Developing models that generalise across tasks and individuals will pave the way for ML network architectures capable of adapting to EEG data collected from diverse tasks and individuals. Similarly, predicting mental health-relevant personality trait values from EEG might identify objective biomarkers useful for clinical diagnosis and design of personalised treatment for psychological conditions. Ultimately, the advances spurred by this challenge could contribute to the development of computational psychiatry and useful neurotechnology, and contribute to breakthroughs in both fundamental neuroscience and applied clinical research.

  • 19 authors
·
Jun 23, 2025

NeuroRVQ: Multi-Scale EEG Tokenization for Generative Large Brainwave Models

Electroencephalography (EEG) captures neural activity across multiple temporal and spectral scales, yielding signals that are rich but complex for representation learning. Recently, EEG foundation models trained to predict masked signal-tokens have shown promise for learning generalizable representations. However, their performance is hindered by their signal tokenization modules. Existing neural tokenizers fail to preserve high-frequency dynamics, limiting their ability to reconstruct EEG signals with high fidelity. We introduce NeuroRVQ, a scalable Large Brainwave Model (LBM) centered on a codebook-based tokenizer. Our tokenizer integrates: (i) multi-scale feature extraction modules that capture the full frequency neural spectrum; (ii) hierarchical residual vector quantization (RVQ) codebooks for high-resolution encoding; and, (iii) an EEG signal phase- and amplitude-aware loss function for efficient training. This design enables efficient EEG compression while supporting accurate reconstruction across all frequency bands, leading to robust generative masked modeling. Our empirical results demonstrate that NeuroRVQ achieves lower reconstruction error and outperforms existing LBMs on a variety of downstream tasks. More broadly, NeuroRVQ tokenizer establishes a strong prior for codebook-based general-purpose brainwave models, enabling advances in neural decoding, generative modeling and multimodal biosignal integration.

  • 7 authors
·
Oct 14, 2025

Deep comparisons of Neural Networks from the EEGNet family

Most of the Brain-Computer Interface (BCI) publications, which propose artificial neural networks for Motor Imagery (MI) Electroencephalography (EEG) signal classification, are presented using one of the BCI Competition datasets. However, these databases contain MI EEG data from less than or equal to 10 subjects . In addition, these algorithms usually include only bandpass filtering to reduce noise and increase signal quality. In this article, we compared 5 well-known neural networks (Shallow ConvNet, Deep ConvNet, EEGNet, EEGNet Fusion, MI-EEGNet) using open-access databases with many subjects next to the BCI Competition 4 2a dataset to acquire statistically significant results. We removed artifacts from the EEG using the FASTER algorithm as a signal processing step. Moreover, we investigated whether transfer learning can further improve the classification results on artifact filtered data. We aimed to rank the neural networks; therefore, next to the classification accuracy, we introduced two additional metrics: the accuracy improvement from chance level and the effect of transfer learning. The former can be used with different class-numbered databases, while the latter can highlight neural networks with sufficient generalization abilities. Our metrics showed that the researchers should not avoid Shallow ConvNet and Deep ConvNet because they can perform better than the later published ones from the EEGNet family.

  • 4 authors
·
Feb 17, 2023

CBraMod: A Criss-Cross Brain Foundation Model for EEG Decoding

Electroencephalography (EEG) is a non-invasive technique to measure and record brain electrical activity, widely used in various BCI and healthcare applications. Early EEG decoding methods rely on supervised learning, limited by specific tasks and datasets, hindering model performance and generalizability. With the success of large language models, there is a growing body of studies focusing on EEG foundation models. However, these studies still leave challenges: Firstly, most of existing EEG foundation models employ full EEG modeling strategy. It models the spatial and temporal dependencies between all EEG patches together, but ignores that the spatial and temporal dependencies are heterogeneous due to the unique structural characteristics of EEG signals. Secondly, existing EEG foundation models have limited generalizability on a wide range of downstream BCI tasks due to varying formats of EEG data, making it challenging to adapt to. To address these challenges, we propose a novel foundation model called CBraMod. Specifically, we devise a criss-cross transformer as the backbone to thoroughly leverage the structural characteristics of EEG signals, which can model spatial and temporal dependencies separately through two parallel attention mechanisms. And we utilize an asymmetric conditional positional encoding scheme which can encode positional information of EEG patches and be easily adapted to the EEG with diverse formats. CBraMod is pre-trained on a very large corpus of EEG through patch-based masked EEG reconstruction. We evaluate CBraMod on up to 10 downstream BCI tasks (12 public datasets). CBraMod achieves the state-of-the-art performance across the wide range of tasks, proving its strong capability and generalizability. The source code is publicly available at https://github.com/wjq-learning/CBraMod.

  • 8 authors
·
Nov 5, 2025

Protecting Intellectual Property of EEG-based Neural Networks with Watermarking

EEG-based neural networks, pivotal in medical diagnosis and brain-computer interfaces, face significant intellectual property (IP) risks due to their reliance on sensitive neurophysiological data and resource-intensive development. Current watermarking methods, particularly those using abstract trigger sets, lack robust authentication and fail to address the unique challenges of EEG models. This paper introduces a cryptographic wonder filter-based watermarking framework tailored for EEG-based neural networks. Leveraging collision-resistant hashing and public-key encryption, the wonder filter embeds the watermark during training, ensuring minimal distortion (leq 5% drop in EEG task accuracy) and high reliability (100\% watermark detection). The framework is rigorously evaluated against adversarial attacks, including fine-tuning, transfer learning, and neuron pruning. Results demonstrate persistent watermark retention, with classification accuracy for watermarked states remaining above 90\% even after aggressive pruning, while primary task performance degrades faster, deterring removal attempts. Piracy resistance is validated by the inability to embed secondary watermarks without severe accuracy loss ( >10% in EEGNet and CCNN models). Cryptographic hashing ensures authentication, reducing brute-force attack success probabilities. Evaluated on the DEAP dataset across models (CCNN, EEGNet, TSception), the method achieves >99.4% null-embedding accuracy, effectively eliminating false positives. By integrating wonder filters with EEG-specific adaptations, this work bridges a critical gap in IP protection for neurophysiological models, offering a secure, tamper-proof solution for healthcare and biometric applications. The framework's robustness against adversarial modifications underscores its potential to safeguard sensitive EEG models while maintaining diagnostic utility.

  • 3 authors
·
Feb 9, 2025

ArtifactGen: Benchmarking WGAN-GP vs Diffusion for Label-Aware EEG Artifact Synthesis

Artifacts in electroencephalography (EEG) -- muscle, eye movement, electrode, chewing, and shiver -- confound automated analysis yet are costly to label at scale. We study whether modern generative models can synthesize realistic, label-aware artifact segments suitable for augmentation and stress-testing. Using the TUH EEG Artifact (TUAR) corpus, we curate subject-wise splits and fixed-length multi-channel windows (e.g., 250 samples) with preprocessing tailored to each model (per-window min--max for adversarial training; per-recording/channel z-score for diffusion). We compare a conditional WGAN-GP with a projection discriminator to a 1D denoising diffusion model with classifier-free guidance, and evaluate along three axes: (i) fidelity via Welch band-power deltas (Deltadelta, Deltatheta, Deltaalpha, Deltabeta), channel-covariance Frobenius distance, autocorrelation L_2, and distributional metrics (MMD/PRD); (ii) specificity via class-conditional recovery with lightweight kNN/classifiers; and (iii) utility via augmentation effects on artifact recognition. In our setting, WGAN-GP achieves closer spectral alignment and lower MMD to real data, while both models exhibit weak class-conditional recovery, limiting immediate augmentation gains and revealing opportunities for stronger conditioning and coverage. We release a reproducible pipeline -- data manifests, training configurations, and evaluation scripts -- to establish a baseline for EEG artifact synthesis and to surface actionable failure modes for future work.

  • 2 authors
·
Sep 9, 2025

NeuroLM: A Universal Multi-task Foundation Model for Bridging the Gap between Language and EEG Signals

Recent advancements for large-scale pre-training with neural signals such as electroencephalogram (EEG) have shown promising results, significantly boosting the development of brain-computer interfaces (BCIs) and healthcare. However, these pre-trained models often require full fine-tuning on each downstream task to achieve substantial improvements, limiting their versatility and usability, and leading to considerable resource wastage. To tackle these challenges, we propose NeuroLM, the first multi-task foundation model that leverages the capabilities of Large Language Models (LLMs) by regarding EEG signals as a foreign language, endowing the model with multi-task learning and inference capabilities. Our approach begins with learning a text-aligned neural tokenizer through vector-quantized temporal-frequency prediction, which encodes EEG signals into discrete neural tokens. These EEG tokens, generated by the frozen vector-quantized (VQ) encoder, are then fed into an LLM that learns causal EEG information via multi-channel autoregression. Consequently, NeuroLM can understand both EEG and language modalities. Finally, multi-task instruction tuning adapts NeuroLM to various downstream tasks. We are the first to demonstrate that, by specific incorporation with LLMs, NeuroLM unifies diverse EEG tasks within a single model through instruction tuning. The largest variant NeuroLM-XL has record-breaking 1.7B parameters for EEG signal processing, and is pre-trained on a large-scale corpus comprising approximately 25,000-hour EEG data. When evaluated on six diverse downstream datasets, NeuroLM showcases the huge potential of this multi-task learning paradigm.

  • 4 authors
·
Mar 19, 2025

EEG-based Cross-Subject Driver Drowsiness Recognition with an Interpretable Convolutional Neural Network

In the context of electroencephalogram (EEG)-based driver drowsiness recognition, it is still challenging to design a calibration-free system, since EEG signals vary significantly among different subjects and recording sessions. Many efforts have been made to use deep learning methods for mental state recognition from EEG signals. However, existing work mostly treats deep learning models as black-box classifiers, while what have been learned by the models and to which extent they are affected by the noise in EEG data are still underexplored. In this paper, we develop a novel convolutional neural network combined with an interpretation technique that allows sample-wise analysis of important features for classification. The network has a compact structure and takes advantage of separable convolutions to process the EEG signals in a spatial-temporal sequence. Results show that the model achieves an average accuracy of 78.35% on 11 subjects for leave-one-out cross-subject drowsiness recognition, which is higher than the conventional baseline methods of 53.40%-72.68% and state-of-the-art deep learning methods of 71.75%-75.19%. Interpretation results indicate the model has learned to recognize biologically meaningful features from EEG signals, e.g., Alpha spindles, as strong indicators of drowsiness across different subjects. In addition, we also explore reasons behind some wrongly classified samples with the interpretation technique and discuss potential ways to improve the recognition accuracy. Our work illustrates a promising direction on using interpretable deep learning models to discover meaningful patterns related to different mental states from complex EEG signals.

  • 4 authors
·
May 30, 2021

DeeperBrain: A Neuro-Grounded EEG Foundation Model Towards Universal BCI

Electroencephalography (EEG) foundation models hold significant promise for universal Brain-Computer Interfaces (BCIs). However, existing approaches often rely on end-to-end fine-tuning and exhibit limited efficacy under frozen-probing protocols, lacking the intrinsic universality required for broad generalization. This limitation stems from adapting general-purpose sequence architectures that overlook the biophysical and dynamical principles of neural activity. To bridge this gap, we propose DeeperBrain, a neuro-grounded foundation model integrating domain-specific inductive biases into its model design and learning objectives. Architecturally, DeeperBrain incorporates a volume conduction-aware channel encoding to model spatial mixing via 3D geometry, and a neurodynamics-aware temporal encoding capturing slow adaptations using oscillatory and exponential bases. For pretraining, we introduce a dual-objective strategy combining Masked EEG Reconstruction (MER) for local fidelity and Neurodynamics Statistics Prediction (NSP). NSP enforces alignment with macroscopic brain states by predicting interpretable order parameters, including spectral power, functional connectivity, cross-frequency coupling, and dynamic complexity. Extensive experiments demonstrate that DeeperBrain achieves state-of-the-art or highly competitive performance under end-to-end fine-tuning. Crucially, it maintains superior efficacy under a rigorous frozen-probing protocol, verifying that embedding neuroscientific first principles endows learned representations with the intrinsic universality essential for universal BCI. The code will be publicly available.

  • 6 authors
·
Jan 5

EEGFormer: Towards Transferable and Interpretable Large-Scale EEG Foundation Model

Self-supervised learning has emerged as a highly effective approach in the fields of natural language processing and computer vision. It is also applicable to brain signals such as electroencephalography (EEG) data, given the abundance of available unlabeled data that exist in a wide spectrum of real-world medical applications ranging from seizure detection to wave analysis. The existing works leveraging self-supervised learning on EEG modeling mainly focus on pretraining upon each individual dataset corresponding to a single downstream task, which cannot leverage the power of abundant data, and they may derive sub-optimal solutions with a lack of generalization. Moreover, these methods rely on end-to-end model learning which is not easy for humans to understand. In this paper, we present a novel EEG foundation model, namely EEGFormer, pretrained on large-scale compound EEG data. The pretrained model cannot only learn universal representations on EEG signals with adaptable performance on various downstream tasks but also provide interpretable outcomes of the useful patterns within the data. To validate the effectiveness of our model, we extensively evaluate it on various downstream tasks and assess the performance under different transfer settings. Furthermore, we demonstrate how the learned model exhibits transferable anomaly detection performance and provides valuable interpretability of the acquired patterns via self-supervised learning.

  • 7 authors
·
Jan 11, 2024

DBConformer: Dual-Branch Convolutional Transformer for EEG Decoding

Electroencephalography (EEG)-based brain-computer interfaces (BCIs) transform spontaneous/evoked neural activity into control commands for external communication. While convolutional neural networks (CNNs) remain the mainstream backbone for EEG decoding, their inherently short receptive field makes it difficult to capture long-range temporal dependencies and global inter-channel relationships. Recent CNN-Transformer (Conformers) hybrids partially address this issue, but most adopt a serial design, resulting in suboptimal integration of local and global features, and often overlook explicit channel-wise modeling. To address these limitations, we propose DBConformer, a dual-branch convolutional Transformer network tailored for EEG decoding. It integrates a temporal Conformer to model long-range temporal dependencies and a spatial Conformer to extract inter-channel interactions, capturing both temporal dynamics and spatial patterns in EEG signals. A lightweight channel attention module further refines spatial representations by assigning data-driven importance to EEG channels. Extensive experiments on five motor imagery (MI) datasets and two seizure detection datasets under three evaluation settings demonstrate that DBConformer consistently outperforms 10 competitive baseline models, with over eight times fewer parameters than the high-capacity EEG Conformer baseline. Further, the visualization results confirm that the features extracted by DBConformer are physiologically interpretable and aligned with sensorimotor priors in MI. The superior performance and interpretability of DBConformer make it reliable for robust and explainable EEG decoding. Code is publicized at https://github.com/wzwvv/DBConformer.

  • 6 authors
·
Jun 26, 2025

Representation learning for improved interpretability and classification accuracy of clinical factors from EEG

Despite extensive standardization, diagnostic interviews for mental health disorders encompass substantial subjective judgment. Previous studies have demonstrated that EEG-based neural measures can function as reliable objective correlates of depression, or even predictors of depression and its course. However, their clinical utility has not been fully realized because of 1) the lack of automated ways to deal with the inherent noise associated with EEG data at scale, and 2) the lack of knowledge of which aspects of the EEG signal may be markers of a clinical disorder. Here we adapt an unsupervised pipeline from the recent deep representation learning literature to address these problems by 1) learning a disentangled representation using beta-VAE to denoise the signal, and 2) extracting interpretable features associated with a sparse set of clinical labels using a Symbol-Concept Association Network (SCAN). We demonstrate that our method is able to outperform the canonical hand-engineered baseline classification method on a number of factors, including participant age and depression diagnosis. Furthermore, our method recovers a representation that can be used to automatically extract denoised Event Related Potentials (ERPs) from novel, single EEG trajectories, and supports fast supervised re-mapping to various clinical labels, allowing clinicians to re-use a single EEG representation regardless of updates to the standardized diagnostic system. Finally, single factors of the learned disentangled representations often correspond to meaningful markers of clinical factors, as automatically detected by SCAN, allowing for human interpretability and post-hoc expert analysis of the recommendations made by the model.

  • 9 authors
·
Oct 28, 2020

LEAD: An EEG Foundation Model for Alzheimer's Disease Detection

Electroencephalography (EEG) provides a non-invasive, highly accessible, and cost-effective approach for detecting Alzheimer's disease (AD). However, existing methods, whether based on handcrafted feature engineering or standard deep learning, face three major challenges: 1) the lack of large-scale EEG-based AD datasets for robust representation learning and evaluation; 2) limited cross-subject generalizability; and 3) difficulty in adapting to highly heterogeneous data. To address these challenges, we curate the world's largest EEG-AD corpus to date, comprising 2,238 subjects. Leveraging this unique resource, we propose LEAD, the first foundation model for EEG-based AD detection. Specifically, we design a gated temporal-spatial Transformer that can adapt to EEG recordings with diverse lengths, channel configurations, and sampling rates. In addition, we introduce a subject-regularized training strategy to enhance end-to-end subject-level detection. We further employ medical contrastive learning to pre-train on 13 datasets, including 4 AD datasets and 9 non-AD neurological disorder datasets, and fine-tune/test the model on the other 5 AD datasets. LEAD achieves the best average ranking across all 20 evaluations on 5 downstream datasets, substantially outperforming existing approaches, including state-of-the-art (SOTA) EEG foundation models. These results strongly demonstrate the effectiveness of our proposed method and significant progress for EEG-based AD detection. Source code: https://github.com/DL4mHealth/LEAD

  • 5 authors
·
Sep 24

Decoding speech from non-invasive brain recordings

Decoding language from brain activity is a long-awaited goal in both healthcare and neuroscience. Major milestones have recently been reached thanks to intracranial devices: subject-specific pipelines trained on invasive brain responses to basic language tasks now start to efficiently decode interpretable features (e.g. letters, words, spectrograms). However, scaling this approach to natural speech and non-invasive brain recordings remains a major challenge. Here, we propose a single end-to-end architecture trained with contrastive learning across a large cohort of individuals to predict self-supervised representations of natural speech. We evaluate our model on four public datasets, encompassing 169 volunteers recorded with magneto- or electro-encephalography (M/EEG), while they listened to natural speech. The results show that our model can identify, from 3s of MEG signals, the corresponding speech segment with up to 72.5% top-10 accuracy out of 1,594 distinct segments (and 44% top-1 accuracy), and up to 19.1% out of 2,604 segments for EEG recordings -- hence allowing the decoding of phrases absent from the training set. Model comparison and ablation analyses show that these performances directly benefit from our original design choices, namely the use of (i) a contrastive objective, (ii) pretrained representations of speech and (iii) a common convolutional architecture simultaneously trained across several participants. Together, these results delineate a promising path to decode natural language processing in real time from non-invasive recordings of brain activity.

  • 5 authors
·
Aug 25, 2022 1

Learning Interpretable Representations Leads to Semantically Faithful EEG-to-Text Generation

Pretrained generative models have opened new frontiers in brain decoding by enabling the synthesis of realistic texts and images from non-invasive brain recordings. However, the reliability of such outputs remains questionable--whether they truly reflect semantic activation in the brain, or are merely hallucinated by the powerful generative models. In this paper, we focus on EEG-to-text decoding and address its hallucination issue through the lens of posterior collapse. Acknowledging the underlying mismatch in information capacity between EEG and text, we reframe the decoding task as semantic summarization of core meanings rather than previously verbatim reconstruction of stimulus texts. To this end, we propose the Generative Language Inspection Model (GLIM), which emphasizes learning informative and interpretable EEG representations to improve semantic grounding under heterogeneous and small-scale data conditions. Experiments on the public ZuCo dataset demonstrate that GLIM consistently generates fluent, EEG-grounded sentences without teacher forcing. Moreover, it supports more robust evaluation beyond text similarity, through EEG-text retrieval and zero-shot semantic classification across sentiment categories, relation types, and corpus topics. Together, our architecture and evaluation protocols lay the foundation for reliable and scalable benchmarking in generative brain decoding.

  • 3 authors
·
May 21, 2025

EEGDash Corpus: A Training-Ready Public Corpus for EEG Foundation Models

Foundation models for electroencephalography (EEG) are pretrained on tens of thousands of hours of recordings, and their accuracy grows with that amount. Such data is hard to assemble. The largest sources are clinical archives that cannot be redistributed, and the public sources are spread over several archives, file formats, and licences. We release eegdash-corpus-v0, a training-ready corpus of 77 public EEG datasets, as the gated Hugging Face dataset EEGDash/eegdash-corpus-v0 with the SHA-256 of every file. REVE, the largest published EEG foundation model, names 89 datasets as its pretraining corpus. Twelve cannot be redistributed: four clinical archives that hold 82% of its hours, and eight under no-derivatives licences. The corpus holds the 76 others that REVE's sampling rate allows and one more from REVE's release card: 77 datasets, 14,075 hours from 7,272 subjects, 5.0 million 10-second samples and 6.21 billion tokens per epoch. Every dataset is fetched through EEGDash, converted once with REVE's recipe, and stored in its own buckets of a chunked Zarr store with its licence recorded beside it, so a model can train on the whole store or on any subset of datasets. To test that the store pretrains a model, we retrain REVE-Base from scratch twice with the authors' code, changed only in how it reads data, and score it on seven public OpenEEGBench tasks. It reaches 0.331 under linear probing and 0.273 after fine-tuning, against 0.333 and 0.325 for the released model and 0.200 and 0.205 for an untrained encoder. The converter, the conversion reports, and the loader changes are released with the corpus.

  • 3 authors
·
Nov 3

NeuroBOLT: Resting-state EEG-to-fMRI Synthesis with Multi-dimensional Feature Mapping

Functional magnetic resonance imaging (fMRI) is an indispensable tool in modern neuroscience, providing a non-invasive window into whole-brain dynamics at millimeter-scale spatial resolution. However, fMRI is constrained by issues such as high operation costs and immobility. With the rapid advancements in cross-modality synthesis and brain decoding, the use of deep neural networks has emerged as a promising solution for inferring whole-brain, high-resolution fMRI features directly from electroencephalography (EEG), a more widely accessible and portable neuroimaging modality. Nonetheless, the complex projection from neural activity to fMRI hemodynamic responses and the spatial ambiguity of EEG pose substantial challenges both in modeling and interpretability. Relatively few studies to date have developed approaches for EEG-fMRI translation, and although they have made significant strides, the inference of fMRI signals in a given study has been limited to a small set of brain areas and to a single condition (i.e., either resting-state or a specific task). The capability to predict fMRI signals in other brain areas, as well as to generalize across conditions, remain critical gaps in the field. To tackle these challenges, we introduce a novel and generalizable framework: NeuroBOLT, i.e., Neuro-to-BOLD Transformer, which leverages multi-dimensional representation learning from temporal, spatial, and spectral domains to translate raw EEG data to the corresponding fMRI activity signals across the brain. Our experiments demonstrate that NeuroBOLT effectively reconstructs unseen resting-state fMRI signals from primary sensory, high-level cognitive areas, and deep subcortical brain regions, achieving state-of-the-art accuracy with the potential to generalize across varying conditions and sites, which significantly advances the integration of these two modalities.

  • 10 authors
·
Oct 6, 2024

Geometric Machine Learning on EEG Signals

Brain-computer interfaces (BCIs) offer transformative potential, but decoding neural signals presents significant challenges. The core premise of this paper is built around demonstrating methods to elucidate the underlying low-dimensional geometric structure present in high-dimensional brainwave data in order to assist in downstream BCI-related neural classification tasks. We demonstrate two pipelines related to electroencephalography (EEG) signal processing: (1) a preliminary pipeline removing noise from individual EEG channels, and (2) a downstream manifold learning pipeline uncovering geometric structure across networks of EEG channels. We conduct preliminary validation using two EEG datasets and situate our demonstration in the context of the BCI-relevant imagined digit decoding problem. Our preliminary pipeline uses an attention-based EEG filtration network to extract clean signal from individual EEG channels. Our primary pipeline uses a fast Fourier transform, a Laplacian eigenmap, a discrete analog of Ricci flow via Ollivier's notion of Ricci curvature, and a graph convolutional network to perform dimensionality reduction on high-dimensional multi-channel EEG data in order to enable regularizable downstream classification. Our system achieves competitive performance with existing signal processing and classification benchmarks; we demonstrate a mean test correlation coefficient of >0.95 at 2 dB on semi-synthetic neural denoising and a downstream EEG-based classification accuracy of 0.97 on distinguishing digit- versus non-digit- thoughts. Results are preliminary and our geometric machine learning pipeline should be validated by more extensive follow-up studies; generalizing these results to larger inter-subject sample sizes, different hardware systems, and broader use cases will be crucial.

  • 1 authors
·
Feb 7, 2025

NeuraDock Visual Cognitive Load Agent Tutorial: A Quality-Gated Open-Source EEG Workflow for Alpha Dynamics and Real-Time Applications

This tutorial paper provides a step-by-step, reproducible walkthrough of NeuraDock Agent, an open-source EEG agent focused on Alpha dynamics and visual cognitive-load analysis. The goal is practical: a reader should be able to install the agent, run EEG preprocessing and quality control, generate Alpha dynamics figures, perform within-subject Rest/Task visual cognitive-load comparison, run the public mini-dataset analyses and compare them with the reference validation summary, start an online dashboard, call the real-time API from an external application, and use the LLM interpretation layer to explain quality risks. Existing EEG toolkits provide excellent offline analysis, but assembling a real-time, quality-gated cognitive-load pipeline often requires manually bridging acquisition, custom QC, Alpha feature extraction, and a web API; this tutorial closes that offline-to-online gap. The tutorial uses a quality-gated workflow: downstream Alpha and workload metrics are computed only after preprocessing and QC gating rather than directly from raw EEG. In the included mini-dataset validation, the agent processed 18 recordings, generated 10 within-subject comparisons, observed task-related posterior Alpha suppression in 7 of 10 contrasts, estimated initial evidence of within-subject repeatability, and benchmarked local online API latency. The tutorial is intended for researchers, developers, and applied teams who want a transparent path from EEG files to real-time visual cognitive-load prototypes.

  • 4 authors
·
Jun 24 1

PhysioWave-T: Token-Efficient Wavelet Foundation Models for Biosignals

We present PhysioWave-T, a token-efficient wavelet foundation model family for EEG, ECG, and sEMG. Dynamic scale folding recombines J+1 wavelet subbands prior to tokenization, compressing sequence length from (J+1)CS to CS tokens for J levels, C channels, and S temporal patches. Route-specific front ends and learned channel-name embeddings allow one Transformer per modality to handle diverse montages and sampling rates, while unseen setups reuse the backbone via lightweight adapters. We pre-train a 30M-parameter EEG model on over 15M windows (19--128 channels), alongside ECG (30M) and sEMG (12M) encoders. Across four EEG routes, scale folding cuts Transformer latency by 4.0--7.2x and peak memory by 6.8--12.7x over scale expansion without accuracy loss. Our EEG encoder leads 8 of 9 metrics against BENDR, BIOT, LaBraM, and EEGPT, and surpasses LUNA-L on wearable seizure detection with fewer parameters. Reliability-aware latent fusion (RALF) further integrates summary tokens from independently pre-trained encoders via sample-adaptive weights. On SeizeIT2, RALF raises event sensitivity at 11 false alarms/h from 61.4% to 74.4% and window AUPRC from 0.321 to 0.399 over the best unimodal baseline, outperforming weighted-logit and concatenation fusion across all variants. PhysioWave-T also achieves state-of-the-art sEMG accuracies and top macro-F1 on PTB-XL Super and Chapman-Shaoxing. Code and models: https://github.com/ForeverBlue816/PhysioWave.

  • 5 authors
·
Nov 5

A portable solution for simultaneous human movement and mobile EEG acquisition: readiness potential for basketball free-throw shooting

Advances in wireless electroencephalography (EEG) technology promise to record brain-electrical activity in everyday situations. To better understand the relationship between brain activity and natural behavior, it is necessary to monitor human movement patterns. Here, we present a pocketable setup consisting of two smartphones to simultaneously capture human posture and EEG signals. We asked 26 basketball players to shoot 120 free throws each. First, we investigated whether our setup allows us to capture the readiness potential (RP) that precedes voluntary actions. Second, we investigated whether the RP differs between successful and unsuccessful free-throw attempts. The results confirmed the presence of the RP over fronto-central channels, with significant negative deflection at channel Cz, from -400 to 0 ms before movement onset (M pm SE: -6.54 pm 2.26 to -13.52 pm 2.42 μV; z = -2.53 to -3.92; FDR-corrected p = 0.049 to 0.003; r = 0.50 to 0.77). However, the amplitude of the RP was not related to shooting success (all FDR-corrected p > 0.05; maximum mean R^2 = 0.047, i.e., 4.7% explained variance). Preliminary exploratory pose analysis conducted offline indicated the presence of participant-specific variations in posture between successful and unsuccessful shots in 38.5% of participants (10/26), with 4.5% explained variance (maximum mean landmark R^2 = 0.045). We conclude that a highly portable, low-cost and lightweight acquisition setup, consisting of two smartphones and a head-mounted wireless EEG amplifier, is sufficient to monitor complex human movement patterns and associated brain dynamics outside the laboratory.

  • 6 authors
·
Jul 19 1

ERP-FM: A Foundation Model for Universal ERP Analysis

Foundation models have recently shown strong potential for learning generalizable EEG representations, yet their effectiveness for event-related potential (ERP) analysis remains unclear. In this work, we investigate two fundamental questions: 1) can foundation-model learning benefit ERP analysis, and what limits the transfer of existing EEG foundation models to ERP tasks? 2) can the complementary advantages of single-trial and averaged-trial ERP be integrated into a unified training pipeline? To study these questions, we curate a large-scale ERP corpus comprising 1,517,157 single-trial ERPs from 3,696 subjects across 38 datasets and 18 paradigms. Leveraging this corpus, we introduce ERP-FM, to the best of our knowledge, the first foundation model specifically developed for ERP representation learning. ERP-FM uses single-channel tokenization, temporal and spatial positional embeddings, and mixed masked autoencoding for large-scale single-trial pretraining. We compare our model against 17 existing methods on 12 downstream datasets covering ERP event/condition classification and neurological disease classification. Our model achieves the best overall average rank across all evaluated methods. Furthermore, our analyses reveal that both ERP and non-ERP EEG pretraining can provide transferable representations for ERP tasks, while fine-grained temporal tokenization is critical for effectively modeling transient ERP dynamics. We further find that single-trial and averaged-trial ERP play complementary rather than competing roles. Combining single-trial pretraining with averaged-trial downstream adaptation substantially improves neurological disease analysis. Overall, these findings establish an effective foundation-model training pipeline for ERP analysis and represent significant progress toward generalizable ERP representation learning. Source code: https://github.com/DL4mHealth/ERP-FM

  • 6 authors
·
Sep 25

EEG Foundation Models: Progresses, Benchmarking, and Open Problems

Electroencephalography (EEG) foundation models have recently emerged as a promising paradigm for brain-computer interfaces (BCIs), aiming to learn transferable neural representations from large-scale heterogeneous recordings. Despite rapid progresses, there lacks fair and comprehensive comparisons of existing EEG foundation models, due to inconsistent pre-training objectives, preprocessing choices, and downstream evaluation protocols. This paper fills this gap. We first review 50 representative models and organize their design choices into a unified taxonomic framework including data standardization, model architectures, and self-supervised pre-training strategies. We then evaluate 12 open-source foundation models and competitive specialist baselines across 13 EEG datasets spanning nine BCI paradigms. Emphasizing real-world deployments, we consider both cross-subject generalization under a leave-one-subject-out protocol and rapid calibration under a within-subject few-shot setting. We further compare full-parameter fine-tuning with linear probing to assess the transferability of pre-trained representations, and examine the relationship between model scale and downstream performance. Our results indicate that: 1) linear probing is frequently insufficient; 2) specialist models trained from scratch remain competitive across many tasks; and, 3) larger foundation models do not necessarily yield better generalization performance under current data regimes and training practices.

SzCORE as a benchmark: report from the seizure detection challenge at the 2025 AI in Epilepsy and Neurological Disorders Conference

Reliable automatic seizure detection from long-term EEG remains a challenge, as current machine learning models often fail to generalize across patients or clinical settings. Manual EEG review remains the clinical standard, underscoring the need for robust models and standardized evaluation. To rigorously assess algorithm performance, we organized a challenge using a private dataset of continuous EEG recordings from 65 subjects (4,360 hours). Expert neurophysiologists annotated the data, providing ground truth for seizure events. Participants were required to detect seizure onset and duration, with evaluation based on event-based metrics, including sensitivity, precision, F1-score, and false positives per day. The SzCORE framework ensured standardized evaluation. The primary ranking criterion was the event-based F1-score, reflecting clinical relevance by balancing sensitivity and false positives. The challenge received 30 submissions from 19 teams, with 28 algorithms evaluated. Results revealed wide variability in performance, with a top F1-score of 43% (sensitivity 37%, precision 45%), highlighting the ongoing difficulty of seizure detection. The challenge also revealed a gap between reported performance and real-world evaluation, emphasizing the importance of rigorous benchmarking. Compared to previous challenges and commercial systems, the best-performing algorithm in this contest showed improved performance. Importantly, the challenge platform now supports continuous benchmarking, enabling reproducible research, integration of new datasets, and clinical evaluation of seizure detection algorithms using a standardized framework.

  • 4 authors
·
May 19, 2025

CrossPT-EEG: A Benchmark for Cross-Participant and Cross-Time Generalization of EEG-based Visual Decoding

Exploring brain activity in relation to visual perception provides insights into the biological representation of the world. While functional magnetic resonance imaging (fMRI) and magnetoencephalography (MEG) have enabled effective image classification and reconstruction, their high cost and bulk limit practical use. Electroencephalography (EEG), by contrast, offers low cost and excellent temporal resolution, but its potential has been limited by the scarcity of large, high-quality datasets and by block-design experiments that introduce temporal confounds. To fill this gap, we present CrossPT-EEG, a benchmark for cross-participant and cross-time generalization of visual decoding from EEG. We collected EEG data from 16 participants while they viewed 4,000 images sampled from ImageNet, with image stimuli annotated at multiple levels of granularity. Our design includes two stages separated in time to allow cross-time generalization and avoid block-design artifacts. We also introduce benchmarks tailored to non-block design classification, as well as pre-training experiments to assess cross-time and cross-participant generalization. These findings highlight the dataset's potential to enhance EEG-based visual brain-computer interfaces, deepen our understanding of visual perception in biological systems, and suggest promising applications for improving machine vision models.

  • 4 authors
·
Dec 15, 2025

Continuous online sequence learning with an unsupervised neural network model

The ability to recognize and predict temporal sequences of sensory inputs is vital for survival in natural environments. Based on many known properties of cortical neurons, hierarchical temporal memory (HTM) sequence memory is recently proposed as a theoretical framework for sequence learning in the cortex. In this paper, we analyze properties of HTM sequence memory and apply it to sequence learning and prediction problems with streaming data. We show the model is able to continuously learn a large number of variable-order temporal sequences using an unsupervised Hebbian-like learning rule. The sparse temporal codes formed by the model can robustly handle branching temporal sequences by maintaining multiple predictions until there is sufficient disambiguating evidence. We compare the HTM sequence memory with other sequence learning algorithms, including statistical methods: autoregressive integrated moving average (ARIMA), feedforward neural networks: online sequential extreme learning machine (ELM), and recurrent neural networks: long short-term memory (LSTM) and echo-state networks (ESN), on sequence prediction problems with both artificial and real-world data. The HTM model achieves comparable accuracy to other state-of-the-art algorithms. The model also exhibits properties that are critical for sequence learning, including continuous online learning, the ability to handle multiple predictions and branching sequences with high order statistics, robustness to sensor noise and fault tolerance, and good performance without task-specific hyper- parameters tuning. Therefore the HTM sequence memory not only advances our understanding of how the brain may solve the sequence learning problem, but is also applicable to a wide range of real-world problems such as discrete and continuous sequence prediction, anomaly detection, and sequence classification.

  • 3 authors
·
Dec 16, 2015

MANAS-2: Constrained Reconstruction for EEG Foundation Models

Masked reconstruction is widely used for EEG foundation models, but optimizing reconstruction on low-SNR waveforms does not necessarily produce the most useful latent representation. We introduce MANAS-2, a new EEG foundation model that combines a Raw-Band Hybrid (RBH) masked autoencoder with Constrained Reconstruction (ConRec), a physics-motivated regularizer. RBH jointly reconstructs temporal waveform patches and compact spectral-band targets, while ConRec acts only on the temporal decoder output, penalizing differences in RMS energy between adjacent short windows of the reconstructed waveform. ConRec is intended to shape the encoder by biasing it toward the organization of oscillatory-envelope information. Across seven held-out EEG datasets, adding ConRec to an otherwise identical RBH model increases frozen ridge recovery of six-band spectral power from mean R^2=0.860 to 0.906 and recovery of inter-patch band-energy dynamics from R^2=0.283 to 0.354, while temporal waveform information remains highly recoverable from the frozen latents. Applied to a temporal-only masked autoencoder, ConRec also improves frozen downstream transfer and frequency-dependent latent geometry despite receiving no spectral targets: i.e., the effects of ConRec are architecture-independent. MANAS-2 also outperforms leading EEG Foundation Models on most downstream knowledge-transfer tasks. From the effects of ConRec, we see that a physically motivated constraint imposed through the decoder can make for a more spectrally organized and transferable latent space. MANAS-2 therefore provides a new EEG foundation model built around constrained reconstruction as a mechanism for shaping representation--rather than reconstruction--quality.

  • 8 authors
·
Sep 14

NeuroSonic: Conditional Flow Matching for EEG-to-Speech Reconstruction

Reconstructing continuous speech from scalp electroencephalography (EEG) remains fundamentally challenging. EEG provides a weak, spatially diffuse, and highly variable measurement of distributed cortical activity, whereas speech is organized as a coherent acoustic trajectory with strong harmonic and temporal structure. The resulting mismatch makes waveform regression unstable and causes stochastic multi-step generation to be sensitive to artifact-dependent conditioning and subject variability. We introduce NeuroSonic, a conditional flow-matching framework for EEG-to-speech reconstruction. Instead of predicting waveforms directly or refining them through stochastic denoising, NeuroSonic learns a deterministic probability-flow velocity field that transports a noise-corrupted acoustic state toward clean speech under EEG conditioning. EEG and audio are embedded into a shared token space and processed by a time-conditioned gated Transformer that parameterizes the transport ordinary differential equation. This formulation models trajectory evolution explicitly while avoiding iterative stochastic sampling. We evaluate NeuroSonic on the CineBrain and EAV benchmarks under cross-subject evaluation. Across both datasets, the proposed method improves distributional realism, spectral fidelity, and perceptual quality over representative GAN-, diffusion-, and mean-flow baselines, with up to a 26.3\% gain in overall perceptual quality. The performance gap is most evident in artifact-heavy segments, where conditioning variability is strongest. These findings indicate that deterministic conditional transport provides a stable and effective formulation for EEG-driven speech reconstruction. Code is available at https://github.com/Y-Research-SBU/NeuroSonic/ .

  • 6 authors
·
Jun 22

Pseudo-online framework for BCI evaluation: A MOABB perspective

Objective: BCI (Brain-Computer Interface) technology operates in three modes: online, offline, and pseudo-online. In the online mode, real-time EEG data is constantly analyzed. In offline mode, the signal is acquired and processed afterwards. The pseudo-online mode processes collected data as if they were received in real-time. The main difference is that the offline mode often analyzes the whole data, while the online and pseudo-online modes only analyze data in short time windows. Offline analysis is usually done with asynchronous BCIs, which restricts analysis to predefined time windows. Asynchronous BCI, compatible with online and pseudo-online modes, allows flexible mental activity duration. Offline processing tends to be more accurate, while online analysis is better for therapeutic applications. Pseudo-online implementation approximates online processing without real-time constraints. Many BCI studies being offline introduce biases compared to real-life scenarios, impacting classification algorithm performance. Approach: The objective of this research paper is therefore to extend the current MOABB framework, operating in offline mode, so as to allow a comparison of different algorithms in a pseudo-online setting with the use of a technology based on overlapping sliding windows. To do this will require the introduction of a idle state event in the dataset that takes into account all different possibilities that are not task thinking. To validate the performance of the algorithms we will use the normalized Matthews Correlation Coefficient (nMCC) and the Information Transfer Rate (ITR). Main results: We analyzed the state-of-the-art algorithms of the last 15 years over several Motor Imagery (MI) datasets composed by several subjects, showing the differences between the two approaches from a statistical point of view. Significance: The ability to analyze the performance of different algorithms in offline and pseudo-online modes will allow the BCI community to obtain more accurate and comprehensive reports regarding the performance of classification algorithms.

  • 2 authors
·
Aug 21, 2023

Neural State Prediction: Obstructing Shortcut Learning in EEG Foundation Models

EEG foundation models increasingly use masked prediction to learn from unlabeled recordings, but optimizing this objective does not ensure transferable neural representations. A central challenge is that stable positional cues and local correlations can make masked regions predictable without integrating distributed neural context. To reduce this reliance on low-information prediction paths, we introduce Neural State Prediction (NSP), a latent-predictive framework that constrains both the prediction target and the available context. NSP uses a Target Encoder updated by an exponential moving average (EMA) to define latent supervision. Identity residualization removes additive effects associated with channel identity and relative time from the targets, while topology-separated context excludes their immediate spatial and temporal neighborhood from the visible input. We pretrain NSP on 2.2 million EEG segments from TUEG and evaluate it across 30 downstream datasets spanning clinical diagnosis, sleep staging, emotion recognition, motor imagery, event-related potentials, cognitive-state decoding, and language retrieval. Under full-parameter multi-task fine-tuning on EEG-FM-Bench, NSP achieves 63.94 macro balanced accuracy across 14 datasets, exceeding the strongest evaluated baseline by 2.35 percentage points. Controlled component ablations assess the contribution of each mechanism, while matched context controls and held-out interventions characterize the role of context geometry, signal content, and positional information. Jointly designing latent targets and their context offers a promising direction for EEG foundation models that learn from distributed signal structure.

  • 5 authors
·
Sep 25

Tokenizing Single-Channel EEG with Time-Frequency Motif Learning

Foundation models are reshaping EEG analysis, yet an important problem of EEG tokenization remains a challenge. This paper presents TFM-Tokenizer, a novel tokenization framework that learns a vocabulary of time-frequency motifs from single-channel EEG signals and encodes them into discrete tokens. We propose a dual-path architecture with time-frequency masking to capture robust motif representations, and it is model-agnostic, supporting both lightweight transformers and existing foundation models for downstream tasks. Our study demonstrates three key benefits: Accuracy: Experiments on four diverse EEG benchmarks demonstrate consistent performance gains across both single- and multi-dataset pretraining settings, achieving up to 17% improvement in Cohen's Kappa over strong baselines. Generalization: Moreover, as a plug-and-play component, it consistently boosts the performance of diverse foundation models, including BIOT and LaBraM. Scalability: By operating at the single-channel level rather than relying on the strict 10-20 EEG system, our method has the potential to be device-agnostic. Experiments on ear-EEG sleep staging, which differs from the pretraining data in signal format, channel configuration, recording device, and task, show that our tokenizer outperforms baselines by 14%. A comprehensive token analysis reveals strong class-discriminative, frequency-aware, and consistent structure, enabling improved representation quality and interpretability. Code is available at https://github.com/Jathurshan0330/TFM-Tokenizer.

  • 4 authors
·
Feb 21, 2025

LaBraM at Scale: Scaling Data and Models for EEG Pretraining

LaBraM, an early EEG foundation model, demonstrated that large-scale EEG pretraining can yield strong representations for diverse downstream tasks. Building on this foundation, we expand pretraining data and model capacity while retaining its core encoder and objective. We train ten encoders with 5.8 million to 1.97 billion parameters on three EEG collections spanning 25,067 to 79,910 hours, adapting signal preparation and training to heterogeneous recordings. Across 23 tasks, Atom-L* reaches 59.05% mean balanced accuracy at its best evaluated full fine-tuning (Full-FT) checkpoint, 3.61 percentage points above the strongest baseline EEG foundation model. Quark-G leads linear probing (LP) at 54.33%, a 1.24-point margin. Both also lead average task rank. At the last evaluated checkpoints, larger encoders improve Full-FT more consistently than LP, and stronger LP does not guarantee stronger Full-FT. Preserving patch structure improves LP over average pooling. Data-fraction experiments suggest capacity-dependent saturation, while checkpoint trajectories show that downstream performance can decline as pretraining loss falls. Joint classification with a shared Qwen3 readout reaches 50.50% with Molecule-H and Qwen3-8B; increasing language-model size provides no consistent gain. These results demonstrate the value of scaling LaBraM and the importance of matching pretraining scale to downstream adaptation.

  • 6 authors
·
Nov 1

ChineseEEG-2: An EEG Dataset for Multimodal Semantic Alignment and Neural Decoding during Reading and Listening

EEG-based neural decoding requires large-scale benchmark datasets. Paired brain-language data across speaking, listening, and reading modalities are essential for aligning neural activity with the semantic representation of large language models (LLMs). However, such datasets are rare, especially for non-English languages. Here, we present ChineseEEG-2, a high-density EEG dataset designed for benchmarking neural decoding models under real-world language tasks. Building on our previous ChineseEEG dataset, which focused on silent reading, ChineseEEG-2 adds two active modalities: Reading Aloud (RA) and Passive Listening (PL), using the same Chinese corpus. EEG and audio were simultaneously recorded from four participants during ~10.7 hours of reading aloud. These recordings were then played to eight other participants, collecting ~21.6 hours of EEG during listening. This setup enables speech temporal and semantic alignment across the RA and PL modalities. ChineseEEG-2 includes EEG signals, precise audio, aligned semantic embeddings from pre-trained language models, and task labels. Together with ChineseEEG, this dataset supports joint semantic alignment learning across speaking, listening, and reading. It enables benchmarking of neural decoding algorithms and promotes brain-LLM alignment under multimodal language tasks, especially in Chinese. ChineseEEG-2 provides a benchmark dataset for next-generation neural semantic decoding.

  • 11 authors
·
Aug 5, 2025

FBCNet: A Multi-view Convolutional Neural Network for Brain-Computer Interface

Lack of adequate training samples and noisy high-dimensional features are key challenges faced by Motor Imagery (MI) decoding algorithms for electroencephalogram (EEG) based Brain-Computer Interface (BCI). To address these challenges, inspired from neuro-physiological signatures of MI, this paper proposes a novel Filter-Bank Convolutional Network (FBCNet) for MI classification. FBCNet employs a multi-view data representation followed by spatial filtering to extract spectro-spatially discriminative features. This multistage approach enables efficient training of the network even when limited training data is available. More significantly, in FBCNet, we propose a novel Variance layer that effectively aggregates the EEG time-domain information. With this design, we compare FBCNet with state-of-the-art (SOTA) BCI algorithm on four MI datasets: The BCI competition IV dataset 2a (BCIC-IV-2a), the OpenBMI dataset, and two large datasets from chronic stroke patients. The results show that, by achieving 76.20% 4-class classification accuracy, FBCNet sets a new SOTA for BCIC-IV-2a dataset. On the other three datasets, FBCNet yields up to 8% higher binary classification accuracies. Additionally, using explainable AI techniques we present one of the first reports about the differences in discriminative EEG features between healthy subjects and stroke patients. Also, the FBCNet source code is available at https://github.com/ravikiran-mane/FBCNet.

  • 8 authors
·
Mar 16, 2021

CodeBrain: Towards Decoupled Interpretability and Multi-Scale Architecture for EEG Foundation Model

Electroencephalography (EEG) provides real-time insights into brain activity and supports diverse applications in neuroscience. While EEG foundation models (EFMs) have emerged to address the scalability issues of task-specific models, current approaches still yield clinically uninterpretable and weakly discriminative representations, inefficiently capture global dependencies, and neglect important local neural events. We present CodeBrain, a two-stage EFM designed to fill this gap. In the first stage, we introduce the TFDual-Tokenizer, which decouples heterogeneous temporal and frequency EEG signals into discrete tokens, quadratically expanding the representation space to enhance discriminative power and offering domain-specific interpretability by suggesting potential links to neural events and spectral rhythms. In the second stage, we propose the multi-scale EEGSSM architecture, which combines structured global convolution with sliding window attention to efficiently capture both sparse long-range and local dependencies, reflecting the brain's small-world topology. Pretrained on the largest public EEG corpus, CodeBrain achieves strong generalization across 8 downstream tasks and 10 datasets under distribution shifts, supported by comprehensive ablations, scaling-law analyses, and interpretability evaluations. Both code and pretraining weights will be released in the future version.

  • 7 authors
·
Sep 24, 2025

Chirp Localization via Fine-Tuned Transformer Model: A Proof-of-Concept Study

Spectrograms are pivotal in time-frequency signal analysis, widely used in audio processing and computational neuroscience. Chirp-like patterns in electroencephalogram (EEG) spectrograms (marked by linear or exponential frequency sweep) are key biomarkers for seizure dynamics, but automated tools for their detection, localization, and feature extraction are lacking. This study bridges this gap by fine-tuning a Vision Transformer (ViT) model on synthetic spectrograms, augmented with Low-Rank Adaptation (LoRA) to boost adaptability. We generated 100000 synthetic spectrograms with chirp parameters, creating the first large-scale benchmark for chirp localization. These spectrograms mimic neural chirps using linear or exponential frequency sweep, Gaussian noise, and smoothing. A ViT model, adapted for regression, predicted chirp parameters. LoRA fine-tuned the attention layers, enabling efficient updates to the pre-trained backbone. Training used MSE loss and the AdamW optimizer, with a learning rate scheduler and early stopping to curb overfitting. Only three features were targeted: Chirp Start Time (Onset Time), Chirp Start Frequency (Onset Frequency), and Chirp End Frequency (Offset Frequency). Performance was evaluated via Pearson correlation between predicted and actual labels. Results showed strong alignment: 0.9841 correlation for chirp start time, with stable inference times (137 to 140s) and minimal bias in error distributions. This approach offers a tool for chirp analysis in EEG time-frequency representation, filling a critical methodological void.

  • 2 authors
·
Mar 24, 2025

FEMBA on the Edge: Physiologically-Aware Pre-Training, Quantization, and Deployment of a Bidirectional Mamba EEG Foundation Model on an Ultra-low Power Microcontroller

Objective: To enable continuous, long-term neuro-monitoring on wearable devices by overcoming the computational bottlenecks of Transformer-based Electroencephalography (EEG) foundation models and the quantization challenges inherent to State-Space Models (SSMs). Methods: We present FEMBA, a bidirectional Mamba architecture pre-trained on over 21,000 hours of EEG. We introduce a novel Physiologically-Aware pre-training objective, consisting of a reconstruction with low-pass filtering, to prioritize neural oscillations over high-frequency artifacts. To address the activation outliers common in SSMs, we employ Quantization-Aware Training (QAT) to compress the model to 2-bit weights. The framework is deployed on a parallel ultra-low-power RISC-V microcontroller (GAP9) using a custom double-buffered memory streaming scheme. Results: The proposed low-pass pre-training improves downstream AUROC on TUAB from 0.863 to 0.893 and AUPR from 0.862 to 0.898 compared to the best contrastive baseline. QAT successfully compresses weights with negligible performance loss, whereas standard post-training quantization degrades accuracy by approximately 30\%. The embedded implementation achieves deterministic real-time inference (1.70~s per 5~s window) and reduces the memory footprint by 74\% (to approx2~MB), achieving competitive accuracy with up to 27times fewer FLOPs than Transformer benchmarks. Conclusion: FEMBA demonstrates that Mamba-based foundation models can be effectively quantized and deployed on extreme-edge hardware without sacrificing the representation quality required for robust clinical analysis. Significance: This work establishes the first full-stack framework for deploying large-scale EEG foundation models on ultra-low-power wearables, facilitating continuous, SSM based monitoring for epilepsy and sleep disorders.

  • 6 authors
·
Mar 17

EEG-FM-Bench: A Comprehensive Benchmark for the Systematic Evaluation of EEG Foundation Models

Electroencephalography foundation models (EEG-FMs) have advanced brain signal analysis, but the lack of standardized evaluation benchmarks impedes model comparison and scientific progress. Current evaluations rely on inconsistent protocols that render cross-model comparisons unreliable, while a lack of diagnostic analyses obscures the internal mechanisms driving transfer efficiency and scaling behaviors. To address this, we introduce EEG-FM-Bench, a unified system for the standardized evaluation of EEG-FMs. The benchmark integrates 14 datasets across 10 paradigms and incorporates diverse experimental settings, including multiple fine-tuning strategies, task organizations, and classifier configurations, supported by tools for gradient and representation analysis. Our experiments and analysis reveal several critical insights: (1) multi-task learning acts as a critical regularizer to mitigate overfitting in data-scarce EEG contexts; (2) pre-training efficiency is currently limited by gradient conflicts between reconstruction objectives and downstream tasks; (3) model scaling deviates from typical laws, as compact architectures with domain-specific inductive biases consistently outperform significantly larger models. This benchmark enables fair comparison and reproducible analysis, shifting the field from fragmented results to interpretable advances. Code is available at https://github.com/xw1216/EEG-FM-Bench.

  • 5 authors
·
Feb 12

FEMBA: Efficient and Scalable EEG Analysis with a Bidirectional Mamba Foundation Model

Accurate and efficient electroencephalography (EEG) analysis is essential for detecting seizures and artifacts in long-term monitoring, with applications spanning hospital diagnostics to wearable health devices. Robust EEG analytics have the potential to greatly improve patient care. However, traditional deep learning models, especially Transformer-based architectures, are hindered by their quadratic time and memory complexity, making them less suitable for resource-constrained environments. To address these challenges, we present FEMBA (Foundational EEG Mamba + Bidirectional Architecture), a novel self-supervised framework that establishes new efficiency benchmarks for EEG analysis through bidirectional state-space modeling. Unlike Transformer-based models, which incur quadratic time and memory complexity, FEMBA scales linearly with sequence length, enabling more scalable and efficient processing of extended EEG recordings. Trained on over 21,000 hours of unlabeled EEG and fine-tuned on three downstream tasks, FEMBA achieves competitive performance in comparison with transformer models, with significantly lower computational cost. Specifically, it reaches 81.82% balanced accuracy (0.8921 AUROC) on TUAB and 0.949 AUROC on TUAR, while a tiny 7.8M-parameter variant demonstrates viability for resource-constrained devices. These results pave the way for scalable, general-purpose EEG analytics in both clinical and highlight FEMBA as a promising candidate for wearable applications.

PulpBio Pulp Platform Bio
·
Feb 10, 2025

BrainPro: Process-conditioned Pretraining with Topographic Retrieval for Large EEG Models

EEG foundation models are pretrained on heterogeneous corpora, but two challenges remain underexplored: (1) experimental protocols provide mental-process cues that are rarely used in masked pretraining, and (2) electrode montages vary across datasets, making spatial representations montage-dependent. Existing methods typically learn a single general-purpose representation and model spatial structure implicitly, limiting their ability to exploit process-related information under montage heterogeneity. We introduce BrainPro, a process-conditioned self-supervised pretraining framework that couples topographic retrieval with shared and process-associated representation learning. BrainPro maps dataset-specific montages to a universal channel-region template and retrieves channel- and region-level spatial filters to form a topographically aligned spatial basis. Over this basis, BrainPro learns a shared encoder for general EEG structure and additional affective, motor-related, and auxiliary residual branches for process-associated variation. Protocol-derived mental-process cues condition branch activation and region-weighted masked reconstruction, incorporating topographic spatial priors and process information. Across nine public BCI benchmarks, BrainPro achieves strong performance among evaluated baselines. Ablations, channel-drop analysis, encoder-configuration studies, and spatial-filter visualizations suggest that topographic retrieval and process-conditioned representation learning jointly improve EEG decoding. Our code is available at https://github.com/yi-ding-cs/BrainPro.

  • 9 authors
·
Oct 20

MODMA dataset: a Multi-modal Open Dataset for Mental-disorder Analysis

According to the World Health Organization, the number of mental disorder patients, especially depression patients, has grown rapidly and become a leading contributor to the global burden of disease. However, the present common practice of depression diagnosis is based on interviews and clinical scales carried out by doctors, which is not only labor-consuming but also time-consuming. One important reason is due to the lack of physiological indicators for mental disorders. With the rising of tools such as data mining and artificial intelligence, using physiological data to explore new possible physiological indicators of mental disorder and creating new applications for mental disorder diagnosis has become a new research hot topic. However, good quality physiological data for mental disorder patients are hard to acquire. We present a multi-modal open dataset for mental-disorder analysis. The dataset includes EEG and audio data from clinically depressed patients and matching normal controls. All our patients were carefully diagnosed and selected by professional psychiatrists in hospitals. The EEG dataset includes not only data collected using traditional 128-electrodes mounted elastic cap, but also a novel wearable 3-electrode EEG collector for pervasive applications. The 128-electrodes EEG signals of 53 subjects were recorded as both in resting state and under stimulation; the 3-electrode EEG signals of 55 subjects were recorded in resting state; the audio data of 52 subjects were recorded during interviewing, reading, and picture description. We encourage other researchers in the field to use it for testing their methods of mental-disorder analysis.

  • 26 authors
·
Feb 20, 2020

Test-Time Adaptation for EEG Foundation Models: A Systematic Study under Real-World Distribution Shifts

Electroencephalography (EEG) foundation models have shown strong potential for learning generalizable representations from large-scale neural data, yet their clinical deployment is hindered by distribution shifts across clinical settings, devices, and populations. Test-time adaptation (TTA) offers a promising solution by enabling models to adapt to unlabeled target data during inference without access to source data, a valuable property in healthcare settings constrained by privacy regulations and limited labeled data. However, its effectiveness for EEG remains largely underexplored. In this work, we introduce NeuroAdapt-Bench, a systematic benchmark for evaluating test-time adaptation methods on EEG foundation models under realistic distribution shifts. We evaluate representative TTA approaches from other domains across multiple pretrained foundation models, diverse downstream tasks, and heterogeneous datasets spanning in-distribution, out-of-distribution, and extreme modality shifts (e.g., Ear-EEG). Our results show that standard TTA methods yield inconsistent gains and often degrade performance, with gradient-based approaches particularly prone to heavy degradation. In contrast, optimization-free methods demonstrate greater stability and more reliable improvements. These findings highlight the limitations of existing TTA techniques in EEG, provide guidance for future development, and underscore the need for domain-specific adaptation strategies.

  • 3 authors
·
Apr 17 2

PyNoetic: A modular python framework for no-code development of EEG brain-computer interfaces

Electroencephalography (EEG)-based Brain-Computer Interfaces (BCIs) have emerged as a transformative technology with applications spanning robotics, virtual reality, medicine, and rehabilitation. However, existing BCI frameworks face several limitations, including a lack of stage-wise flexibility essential for experimental research, steep learning curves for researchers without programming expertise, elevated costs due to reliance on proprietary software, and a lack of all-inclusive features leading to the use of multiple external tools affecting research outcomes. To address these challenges, we present PyNoetic, a modular BCI framework designed to cater to the diverse needs of BCI research. PyNoetic is one of the very few frameworks in Python that encompasses the entire BCI design pipeline, from stimulus presentation and data acquisition to channel selection, filtering, feature extraction, artifact removal, and finally simulation and visualization. Notably, PyNoetic introduces an intuitive and end-to-end GUI coupled with a unique pick-and-place configurable flowchart for no-code BCI design, making it accessible to researchers with minimal programming experience. For advanced users, it facilitates the seamless integration of custom functionalities and novel algorithms with minimal coding, ensuring adaptability at each design stage. PyNoetic also includes a rich array of analytical tools such as machine learning models, brain-connectivity indices, systematic testing functionalities via simulation, and evaluation methods of novel paradigms. PyNoetic's strengths lie in its versatility for both offline and real-time BCI development, which streamlines the design process, allowing researchers to focus on more intricate aspects of BCI development and thus accelerate their research endeavors. Project Website: https://neurodiag.github.io/PyNoetic

MVCNet: Multi-View Contrastive Network for Motor Imagery Classification

Electroencephalography (EEG)-based brain-computer interfaces (BCIs) enable neural interaction by decoding brain activity for external communication. Motor imagery (MI) decoding has received significant attention due to its intuitive mechanism. However, most existing models rely on single-stream architectures and overlook the multi-view nature of EEG signals, leading to limited performance and generalization. We propose a multi-view contrastive network (MVCNet), a dual-branch architecture that parallelly integrates CNN and Transformer models to capture both local spatial-temporal features and global temporal dependencies. To enhance the informativeness of training data, MVCNet incorporates a unified augmentation pipeline across time, frequency, and spatial domains. Two contrastive modules are further introduced: a cross-view contrastive module that enforces consistency of original and augmented views, and a cross-model contrastive module that aligns features extracted from both branches. Final representations are fused and jointly optimized by contrastive and classification losses. Experiments on five public MI datasets across three scenarios demonstrate that MVCNet consistently outperforms seven state-of-the-art MI decoding networks, highlighting its effectiveness and generalization ability. MVCNet provides a robust solution for MI decoding by integrating multi-view information and dual-branch modeling, contributing to the development of more reliable BCI systems.

  • 5 authors
·
Feb 18, 2025

Epileptic seizure forecasting with long short-term memory (LSTM) neural networks

Objective: Forecasting epileptic seizures can reduce uncertainty for patients and allow preventative actions. While many models can predict the occurrence of seizures from features of the EEG, few models incorporate changes in features over time. Long Short-Term Memory (LSTM) neural networks are a machine learning architecture that can display temporal dynamics due to the recurrent connections. In this paper, we used LSTMs to monitor changes in EEG features over time to improve the accuracy of seizure forecasts and to alter the time window of the forecast. Methods: Long-term intracranial EEG recordings from eight patients from the NeuroVista dataset were used. A Fourier transform of 1-minute segments of EEG was fed into a Convolutional Neural Network (CNN). The outputs from the CNN were input to three different LSTM models at different time intervals: 1 minute, 1 hour and 1 day. The LSTM model outputs were used to predict seizure onset within a time window. The prediction and start of the time window were separated by the same length of time as the window. Window sizes tested included 2, 4, 10, 20 and 40 minutes. Results and Conclusion: Our model forecast seizure onsets well above a random predictor. Compared to other models using the same dataset, our model performed better for some patients and worse for others. Monitoring the change in EEG features over time allowed our model to produce good results over a range of different window sizes, which is an improvement on previous models and raises the possibility of altering the forecast to meet individual patient needs. Furthermore, a window size of 40 minutes provides a potential intervention time of 40 minutes, which is the first time an intervention time of more than 5 minutes have been forecast using long-term EEG recordings.

  • 7 authors
·
Sep 18, 2023

QualityFM: a Multimodal Physiological Signal Foundation Model with Self-Distillation for Signal Quality Challenges in Critically Ill Patients

Photoplethysmogram (PPG) and electrocardiogram (ECG) are commonly recorded in intesive care unit (ICU) and operating room (OR). However, the high incidence of poor, incomplete, and inconsistent signal quality, can lead to false alarms or diagnostic inaccuracies. The methods explored so far suffer from limited generalizability, reliance on extensive labeled data, and poor cross-task transferability. To overcome these challenges, we introduce QualityFM, a novel multimodal foundation model for these physiological signals, designed to acquire a general-purpose understanding of signal quality. Our model is pre-trained on an large-scale dataset comprising over 21 million 30-second waveforms and 179,757 hours of data. Our approach involves a dual-track architecture that processes paired physiological signals of differing quality, leveraging a self-distillation strategy where an encoder for high-quality signals is used to guide the training of an encoder for low-quality signals. To efficiently handle long sequential signals and capture essential local quasi-periodic patterns, we integrate a windowed sparse attention mechanism within our Transformer-based model. Furthermore, a composite loss function, which combines direct distillation loss on encoder outputs with indirect reconstruction loss based on power and phase spectra, ensures the preservation of frequency-domain characteristics of the signals. We pre-train three models with varying parameter counts (9.6 M to 319 M) and demonstrate their efficacy and practical value through transfer learning on three distinct clinical tasks: false alarm of ventricular tachycardia detection, the identification of atrial fibrillation and the estimation of arterial blood pressure (ABP) from PPG and ECG signals.

  • 3 authors
·
Sep 8, 2025