new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Aug 4

DermDepth: Toward Monocular Metric Scale 3D Reconstruction Models for Dermatology

Dermatological practice routinely involves measuring and tracking lesion size, morphology and texture, as critical components of wound or skin cancer screening, monitoring and diagnosis. To accomplish this task, practitioners often image the skin surface with commonly available off-the-shelf camera sensors. This has led to an overwhelming research focus on 2D methods while these objectives naturally benefit from 3D information. In this paper, we demonstrate that dense monocular 3D reconstructions, metric scale measurements and rich surface normal texture estimates are achievable for both dermoscopic and macroscopic cases without the need for additional hardware or multiple captures. We present DermDepth, the first single-view metric scale 3D model for the dermatological domain and D-Synth, the first synthetic dermoscopic dataset with pixel-perfect 3D information. Our experiments show training DermDepth on D-Synth corrects metric scale error from over 16x to under 1.1x for real dermoscopic data, while preserving geometric quality and increasing texture richness. Fine-tuning on a small amount of real clinical samples generalizes our method across three real-world benchmarks spanning the few mm to hundred cm range, diverse skin-tones, chronic wound cases and produces measurements broadly consistent with disease size reported in medical literature. All code, data and models are available at https://github.com/hectorcarrion/dermdepth.

  • 2 authors
·
Jul 13

LegSegNet: A Public Deep Learning System for Lower Extremity CT Tissue Segmentation and Quantification

Lower extremity computed tomography (CT) contains clinically relevant information for body composition analysis, sarcopenia assessment, and musculoskeletal disease monitoring, but extracting these measurements at scale requires accurate tissue segmentation and an automated quantification workflow. Existing public segmentation tools are not designed for comprehensive lower extremity CT analysis, particularly for clinically important inter/intramuscular adipose tissue, and most public methods only provide mask prediction rather than an end-to-end quantification system. To address this problem, we present LegSegNet, a deep learning system for lower extremity CT tissue segmentation and body composition quantification. Given an input CT scan, LegSegNet segments bone, skeletal muscle, subcutaneous adipose tissue, and inter/intramuscular adipose tissue. It then computes quantitative tissue measurements for downstream analysis. We developed the segmentation model using 1,302 manually annotated CT slices and evaluated it on 900 held-out test slices, with all annotations reviewed by radiologists. We benchmark LegSegNet against a broad set of 2D segmentation methods, including CNN-based models, transformer-based models, and finetuned foundation models, and further evaluate its generalization on an external public CT dataset. LegSegNet achieves the best overall segmentation performance, with an average Dice score of 89.31 on the held-out test set. To our knowledge, LegSegNet is the first publicly available end-to-end system for lower extremity CT tissue segmentation and quantification, providing a practical evaluation tool for future computer vision research in medical image analysis. The code and model weights are available at: https://github.com/mazurowski-lab/LegSegNet

  • 7 authors
·
May 28

Standardized Benchmark Dataset for Localized Exposure to a Realistic Source at 10-90 GHz

The lack of freely available standardized datasets represents an aggravating factor during the development and testing the performance of novel computational techniques in exposure assessment and dosimetry research. This hinders progress as researchers are required to generate numerical data (field, power and temperature distribution) anew using simulation software for each exposure scenario. Other than being time consuming, this approach is highly susceptible to errors that occur during the configuration of the electromagnetic model. To address this issue, in this paper, the limited available data on the incident power density and resultant maximum temperature rise on the skin surface considering various steady-state exposure scenarios at 10-90 GHz have been statistically modeled. The synthetic data have been sampled from the fitted statistical multivariate distribution with respect to predetermined dosimetric constraints. We thus present a comprehensive and open-source dataset compiled of the high-fidelity numerical data considering various exposures to a realistic source. Furthermore, different surrogate models for predicting maximum temperature rise on the skin surface were fitted based on the synthetic dataset. All surrogate models were tested on the originally available data where satisfactory predictive performance has been demonstrated. A simple technique of combining quadratic polynomial and tensor-product spline surrogates, each operating on its own cluster of data, has achieved the lowest mean absolute error of 0.058 {\deg}C. Therefore, overall experimental results indicate the validity of the proposed synthetic dataset.

  • 3 authors
·
May 3, 2023

Colorimetric skin tone scale for improved accuracy and reduced perceptual bias of human skin tone annotations

Human image datasets used to develop and evaluate technology should represent the diversity of human phenotypes, including skin tone. Datasets that include skin tone information frequently rely on manual skin tone ratings based on the Fitzpatrick Skin Type (FST) or the Monk Skin Tone (MST) scales in lieu of the actual measured skin tone of the image dataset subjects. However, perceived skin tone is subject to known biases and skin tone appearance in digital images can vary substantially depending on the capture camera and environment, confounding manual ratings. Surprisingly, the relationship between skin-tone ratings and measured skin tone has not been explored. To close this research gap, we measured the relationship between skin tone ratings from existing scales (FST, MST) and skin tone values measured by a calibrated colorimeter. We also propose and assess a novel Colorimetric Skin Tone (CST) scale developed based on prior colorimetric measurements. Using experiments requiring humans to rate their own skin tone and the skin tone of subjects in images, we show that the new CST scale is more sensitive, consistent, and colorimetrically accurate. While skin tone ratings appeared to correct for some color variation across images, they introduced biases related to race and other factors. These biases must be considered before using manual skin-tone ratings in technology evaluations or for engineering decisions.

  • 7 authors
·
Oct 27, 2024

A Neural Anthropometer Learning from Body Dimensions Computed on Human 3D Meshes

Human shape estimation has become increasingly important both theoretically and practically, for instance, in 3D mesh estimation, distance garment production and computational forensics, to mention just a few examples. As a further specialization, Human Body Dimensions Estimation (HBDE) focuses on estimating human body measurements like shoulder width or chest circumference from images or 3D meshes usually using supervised learning approaches. The main obstacle in this context is the data scarcity problem, as collecting this ground truth requires expensive and difficult procedures. This obstacle can be overcome by obtaining realistic human measurements from 3D human meshes. However, a) there are no well established methods to calculate HBDs from 3D meshes and b) there are no benchmarks to fairly compare results on the HBDE task. Our contribution is twofold. On the one hand, we present a method to calculate right and left arm length, shoulder width, and inseam (crotch height) from 3D meshes with focus on potential medical, virtual try-on and distance tailoring applications. On the other hand, we use four additional body dimensions calculated using recently published methods to assemble a set of eight body dimensions which we use as a supervision signal to our Neural Anthropometer: a convolutional neural network capable of estimating these dimensions. To assess the estimation, we train the Neural Anthropometer with synthetic images of 3D meshes, from which we calculated the HBDs and observed that the network's overall mean estimate error is 20.89 mm (relative error of 2.84\%). The results we present are fully reproducible and establish a fair baseline for research on the task of HBDE, therefore enabling the community with a valuable method.

  • 2 authors
·
Oct 6, 2021

ATLAS: Decoupling Skeletal and Shape Parameters for Expressive Parametric Human Modeling

Parametric body models offer expressive 3D representation of humans across a wide range of poses, shapes, and facial expressions, typically derived by learning a basis over registered 3D meshes. However, existing human mesh modeling approaches struggle to capture detailed variations across diverse body poses and shapes, largely due to limited training data diversity and restrictive modeling assumptions. Moreover, the common paradigm first optimizes the external body surface using a linear basis, then regresses internal skeletal joints from surface vertices. This approach introduces problematic dependencies between internal skeleton and outer soft tissue, limiting direct control over body height and bone lengths. To address these issues, we present ATLAS, a high-fidelity body model learned from 600k high-resolution scans captured using 240 synchronized cameras. Unlike previous methods, we explicitly decouple the shape and skeleton bases by grounding our mesh representation in the human skeleton. This decoupling enables enhanced shape expressivity, fine-grained customization of body attributes, and keypoint fitting independent of external soft-tissue characteristics. ATLAS outperforms existing methods by fitting unseen subjects in diverse poses more accurately, and quantitative evaluations show that our non-linear pose correctives more effectively capture complex poses compared to linear models.

  • 10 authors
·
Aug 21, 2025 2

Deep Feature Deformation Weights

Handle-based mesh deformation is a classic paradigm in computer graphics which enables intuitive edits from sparse controls. Classical techniques are fast and precise, but require users to know ideal handle placement apriori, which can be unintuitive and inconsistent. Handle sets cannot be adjusted easily, as weights are typically optimized through energies defined by the handles. Modern data-driven methods, on the other hand, provide semantic edits but sacrifice fine-grained control and speed. We propose a technique that achieves the best of both worlds: deep feature proximity yields smooth, visual-aware deformation weights with no additional regularization. Importantly, these weights are computed in real-time for any surface point, unlike prior methods which require expensive optimization. We introduce barycentric feature distillation, an improved feature distillation pipeline which leverages the full visual signal from shape renders to make distillation complexity robust to mesh resolution. This enables high resolution meshes to be processed in minutes versus potentially hours for prior methods. We preserve and extend classical properties through feature space constraints and locality weighting. Our field representation enables automatic visual symmetry detection, which we use to produce symmetry-preserving deformations. We show a proof-of-concept application which can produce deformations for meshes up to 1 million faces in real-time on a consumer-grade machine. Project page at https://threedle.github.io/dfd.

  • 3 authors
·
Mar 24