| "id": "bad-boden-wasserfest", | |
| "roomType": "bad", | |
| "gilt": "boden", | |
| "anforderung": "wasserfest", | |
| "erlaubteMaterialien": [ | |
| "fliesen-hell", | |
| "fliesen-gruen", | |
| "fliesen-anthrazit", | |
| "naturstein", | |
| "beton" | |
| ], | |
| "severity": "hard", | |
| "quelle": "DIN 18534 (W2-I haeusliche Baeder) / SIA 271; Rutschhemmung: bfu 2.032 (GB2/B barfuss nass)", | |
| "status": "richtwert-verifiziert", | |
| "hinweis": "Bad-Boden muss wasserfest sein (Fliesen/Naturstein/Beton) – kein Parkett/Holz/Putz/Tapete. Rutschhemmung: Ziel bfu-Klasse GB2 (DIN 51097 B) fuer Dusch-/Nasszonen – erst prüfbar, wenn Materialien Produktdaten tragen." | |
| }, | |
| { | |
| "id": "bad-wand-nass-wasserfest", | |
| "roomType": "bad", | |
| "gilt": "wand-nass", | |
| "anforderung": "wasserfest", | |
| "minHoeheM": 2.0, | |
| "erlaubteMaterialien": [ | |
| "fliesen-hell", | |
| "fliesen-gruen", | |
| "fliesen-anthrazit", | |
| "naturstein" | |
| ], | |
| "severity": "hard", | |
| "quelle": "DIN 18534: Abdichtung >= 20 cm ueber hoechster Wasserentnahmestelle / SIA 271", | |
| "status": "richtwert-verifiziert", | |
| "hinweis": "Waende mit Wasser-/Abwasser-Anschluss (Dusche/Wanne/Lavabo) wasserfest verkleidet bis >= 2.0 m. DIN 18534: mind. 20 cm ueber Brausekopf – bei hohem Auslass (~2.05 m) eher 2.25 m oder raumhoch." | |
| }, | |
| { | |
| "id": "bad-wand-alle-sockel", | |
| "roomType": "bad", | |
| "gilt": "wand-alle", | |
| "anforderung": "wasserfest", | |
| "minHoeheM": 0.1, | |
| "erlaubteMaterialien": [ | |
| "fliesen-hell", | |
| "fliesen-gruen", | |
| "fliesen-anthrazit", | |
| "naturstein", | |
| "beton" | |
| ], | |
| "severity": "hard", | |
| "quelle": "Praxis – Spritzwasser-/Sockelschutz Nassraum / Richtwert", | |
| "status": "richtwert-plausibel", | |
| "hinweis": "Jede EXPLIZIT belegte Bad-Wand braucht ein wasserfestes Material am Boden (Sockel ≥ 0.1 m). Trockene Wände bleiben unbelegt (Client-Fallback), statt sie mit Putz/Tapete zu belegen." | |
| }, | |
| { | |
| "id": "kueche-boden-abwaschbar", | |
| "roomType": "kueche", | |
| "gilt": "boden", | |
| "anforderung": "abwaschbar", | |
| "erlaubteMaterialien": [ | |
| "fliesen-hell", | |
| "fliesen-gruen", | |
| "fliesen-anthrazit", | |
| "beton", | |
| "naturstein" | |
| ], | |
| "severity": "hard", | |
| "quelle": "Küchen-Detailkonzept / Praxis – strapazierfähiger, abwaschbarer Boden / Richtwert", | |
| "status": "richtwert-plausibel", | |
| "hinweis": "Küchenboden strapazierfähig/abwaschbar (Fliesen/Beton/Naturstein). Parkett-Eiche zwar praxisüblich, hier bewusst streng als Richtwert ausgeschlossen." | |
| }, | |
| { | |
| "id": "kueche-wand-spritzzone", | |
| "roomType": "kueche", | |
| "gilt": "wand-nass", | |
| "anforderung": "wasserfest", | |
| "minHoeheM": 1.5, | |
| "erlaubteMaterialien": [ | |
| "fliesen-hell", | |
| "fliesen-gruen", | |
| "fliesen-anthrazit", | |
| "naturstein", | |
| "beton" | |
| ], | |
| "severity": "hard", | |
| "quelle": "Fachpraxis Fliesenspiegel: Arbeitsplatte ~0.9 m + Nische ~0.6 m = OK ~1.5 m ab Boden; DIN 18534 W1-I", | |
| "status": "richtwert-verifiziert", | |
| "hinweis": "Waende mit Wasser-Anschluss (Spuele/Arbeitsflaeche) wasserfest bis >= 1.5 m ab Boden (Spritzzone endet an OK Fliesenspiegel ~1.5 m, nicht 1.2 m – unsere Zonen messen ab Boden). Greift ueber die Wasser-Fixpunkte der Spuele." | |
| } | |
| ] | |