| """Solar Post-Processing and Capacity-Scaled Evaluation Pipeline. | |
| Converts dimensionless Capacity Factor (0.0 ~ 1.0) into physical Grid Units: | |
| 1. Power (kW) = CF * DC Capacity (kWp) | |
| 2. Inverter AC Clipping (derating if DC/AC ratio > 1.0) | |
| 3. Energy (kWh) = Power (kW) * Time Interval (hours) | |
| 4. Non-crossing Quantiles (P10 <= P50 <= P90) Power Scaling | |
| 5. Grid-Scale Error Metrics (kW and kWh scale MAE, RMSE, WAPE) | |
| """ | |
| from typing import Any, Optional | |
| import numpy as np | |
| from solarlab.geometry.solar_calculator import NIGHT_ZENITH_THRESHOLD_DEG | |
| def post_process_solar_predictions( | |
| capacity_factor: float | np.ndarray, | |
| capacity_kw: float | np.ndarray, | |
| sza_deg: Optional[float | np.ndarray] = None, | |
| interval_hours: float = 1.0, | |
| inverter_ac_kw: Optional[float | np.ndarray] = None, | |
| quantiles_cf: Optional[dict[str, float | np.ndarray]] = None, | |
| ) -> dict[str, Any]: | |
| """Apply physical post-processing and scale dimensionless predictions to physical units. | |
| Parameters | |
| ---------- | |
| capacity_factor : float or np.ndarray | |
| Model output capacity factor (0.0 ~ 1.0). | |
| capacity_kw : float or np.ndarray | |
| Installed DC solar capacity in kWp. | |
| sza_deg : float or np.ndarray, optional | |
| Solar zenith angle in degrees. If > 88°, power is forced to 0.0. | |
| interval_hours : float, default 1.0 | |
| Time interval (1.0 for hourly data, 0.5 for 30-min data). | |
| inverter_ac_kw : float or np.ndarray, optional | |
| Inverter AC maximum capacity limit. | |
| quantiles_cf : dict of str to float or ndarray, optional | |
| Predicted CF quantiles (e.g. {'P10': ..., 'P50': ..., 'P90': ...}). | |
| Returns | |
| ------- | |
| dict | |
| Dictionary containing physical post-processed outputs (power_kw, energy_kwh, etc.) | |
| """ | |
| cf_arr = np.clip(np.asarray(capacity_factor, dtype=np.float32), 0.0, 1.0) | |
| cap_arr = np.asarray(capacity_kw, dtype=np.float32) | |
| # 1. Night-time Zeroing Force | |
| if sza_deg is not None: | |
| sza_arr = np.asarray(sza_deg, dtype=np.float32) | |
| is_night = sza_arr > NIGHT_ZENITH_THRESHOLD_DEG | |
| cf_arr = np.where(is_night, 0.0, cf_arr) | |
| # 2. Power Conversion (kW) | |
| power_kw = cf_arr * cap_arr | |
| # 3. Inverter AC Limit Clipping | |
| if inverter_ac_kw is not None: | |
| inv_limit = np.asarray(inverter_ac_kw, dtype=np.float32) | |
| power_kw = np.minimum(power_kw, inv_limit) | |
| # Recalculate effective CF after inverter clipping | |
| cf_arr = np.where(cap_arr > 0, power_kw / cap_arr, 0.0) | |
| # 4. Energy Conversion (kWh) | |
| energy_kwh = power_kw * interval_hours | |
| # 5. Quantiles Scaling | |
| scaled_quantiles_power = {} | |
| scaled_quantiles_energy = {} | |
| if quantiles_cf: | |
| for q_name, q_val in quantiles_cf.items(): | |
| q_cf_clipped = np.clip(np.asarray(q_val, dtype=np.float32), 0.0, 1.0) | |
| if sza_deg is not None: | |
| q_cf_clipped = np.where(is_night, 0.0, q_cf_clipped) | |
| q_power = q_cf_clipped * cap_arr | |
| if inverter_ac_kw is not None: | |
| q_power = np.minimum(q_power, inv_limit) | |
| scaled_quantiles_power[q_name] = q_power | |
| scaled_quantiles_energy[q_name] = q_power * interval_hours | |
| is_scalar = np.ndim(capacity_factor) == 0 | |
| if is_scalar: | |
| return { | |
| "capacity_factor": float(np.round(cf_arr, 4)), | |
| "power_kw": float(np.round(power_kw, 3)), | |
| "energy_kwh": float(np.round(energy_kwh, 3)), | |
| "quantiles_power_kw": { | |
| k: float(np.round(v, 3)) for k, v in scaled_quantiles_power.items() | |
| }, | |
| "quantiles_energy_kwh": { | |
| k: float(np.round(v, 3)) for k, v in scaled_quantiles_energy.items() | |
| }, | |
| } | |
| return { | |
| "capacity_factor": cf_arr, | |
| "power_kw": power_kw, | |
| "energy_kwh": energy_kwh, | |
| "quantiles_power_kw": scaled_quantiles_power, | |
| "quantiles_energy_kwh": scaled_quantiles_energy, | |
| } | |
| def compute_capacity_scaled_metrics( | |
| y_true_cf: np.ndarray, | |
| y_pred_cf: np.ndarray, | |
| capacities_kw: np.ndarray, | |
| interval_hours: float = 1.0, | |
| ) -> dict[str, float]: | |
| """Compute grid-scale performance metrics in physical units (kW and kWh). | |
| Allows plant operators to directly view errors in tangible power and energy terms. | |
| """ | |
| y_true_cf = np.clip(np.asarray(y_true_cf, dtype=np.float64), 0.0, 1.0) | |
| y_pred_cf = np.clip(np.asarray(y_pred_cf, dtype=np.float64), 0.0, 1.0) | |
| capacities = np.asarray(capacities_kw, dtype=np.float64) | |
| # Actual and predicted power in kW | |
| p_true = y_true_cf * capacities | |
| p_pred = y_pred_cf * capacities | |
| # Actual and predicted energy in kWh | |
| e_true = p_true * interval_hours | |
| e_pred = p_pred * interval_hours | |
| # 1. Power-scale metrics (kW) | |
| mae_kw = float(np.mean(np.abs(p_true - p_pred))) | |
| rmse_kw = float(np.sqrt(np.mean((p_true - p_pred) ** 2))) | |
| sum_p_true = float(np.sum(p_true)) | |
| wape_kw_pct = float(np.sum(np.abs(p_true - p_pred)) / (sum_p_true + 1e-8)) * 100.0 | |
| # 2. Energy-scale metrics (kWh) | |
| mae_kwh = float(np.mean(np.abs(e_true - e_pred))) | |
| total_energy_true_kwh = float(np.sum(e_true)) | |
| total_energy_pred_kwh = float(np.sum(e_pred)) | |
| energy_bias_pct = ( | |
| float((total_energy_pred_kwh - total_energy_true_kwh) / (total_energy_true_kwh + 1e-8)) | |
| * 100.0 | |
| ) | |
| return { | |
| "mae_kw": round(mae_kw, 3), | |
| "rmse_kw": round(rmse_kw, 3), | |
| "wape_pct": round(wape_kw_pct, 2), | |
| "mae_kwh": round(mae_kwh, 3), | |
| "total_energy_true_kwh": round(total_energy_true_kwh, 1), | |
| "total_energy_pred_kwh": round(total_energy_pred_kwh, 1), | |
| "energy_bias_pct": round(energy_bias_pct, 2), | |
| } | |