File size: 57,340 Bytes
6a98735 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 | id,study_id,comparison_group,microphone,mic_category,mic_type,condition,distance_cm,asr_engine,statistic,wer_pct,price_amount,price_currency,price_basis,price_source_url,price_checked,note,source_authors,source_year,source_title,source_venue,source_url,source_limits,wer_gap_to_group_best_pts
1,alander-2025,alander-2025:quiet,Poly Blackwire C5210T,headset,"Headset, wired USB boom",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.96,121.34,EUR,reseller-stated list,https://www.huntoffice.ie/headsets~connection_type=usb-c,2026-11-23,Price is for the current Blackwire 5210 USB-C; equivalence to the tested unit assumed,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.0
2,alander-2025,alander-2025:quiet,Philips SpeechOne PSM6500 series,headset,"Headset, wireless dictation",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.99,618.0,USD,reseller-stated list,https://www.tvps.com/wireless-dictation-headsets/,2026-11-23,PSM6500,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.03
3,alander-2025,alander-2025:quiet,Olympus RecMic DR-2200,handheld_dictation,"Handheld dictation, wired",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.0,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.04
4,alander-2025,alander-2025:quiet,Philips SpeechMike Premium Touch SMP3700/3800,handheld_dictation,"Handheld dictation, wired USB",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.19,423.0,USD,manufacturer list,https://www.dictation.philips.com/us/products/desktop-dictation/,2026-11-23,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.23
5,alander-2025,alander-2025:quiet,Philips SpeechMike wireless,handheld_dictation,"Handheld dictation, wireless",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.26,497.0,USD,manufacturer list,https://www.dictation.philips.com/us/products/desktop-dictation/,2026-11-23,Thesis prints 'SMP400'; SMP4000 assumed,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.3
6,alander-2025,alander-2025:quiet,Olympus RM-4100S,handheld_dictation,"Handheld dictation, wired",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.4,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.44
7,alander-2025,alander-2025:quiet,iPhone 11,phone,"Phone, built-in",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.51,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.55
8,alander-2025,alander-2025:quiet,Logitech H340,headset,"Headset, wired USB boom",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.65,24.99,USD,manufacturer list,https://www.logitech.com/en-us/shop/p/h340-usb-pc-noise-cancelling-mic,2026-11-23,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.69
9,alander-2025,alander-2025:quiet,JBL Tune 520BT,headset,"Headphones, Bluetooth, built-in mic",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",7.48,59.95,USD,manufacturer list,https://www.jbl.com/TUNE520BT.html,2026-11-23,Regular price; another variant on the page is 69.95,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",3.52
10,alander-2025,alander-2025:quiet,HP 255 G8 laptop mic,laptop,"Laptop, built-in",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",11.63,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",7.67
11,alander-2025,alander-2025:quiet,"Logitech USB headset (older, unnamed)",headset,"Headset, wired USB",quiet,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",13.7,,,,,,Very inconsistent results,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",9.74
12,alander-2025,alander-2025:phase 3: no distraction,Philips SpeechOne PSM6500 series,headset,"Headset, wireless dictation",phase 3: no distraction,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.41,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.04
13,alander-2025,alander-2025:phase 3: fan level 1,Philips SpeechOne PSM6500 series,headset,"Headset, wireless dictation",phase 3: fan level 1,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",17.89,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",14.57
14,alander-2025,alander-2025:phase 3: fan level 2 (strongest),Philips SpeechOne PSM6500 series,headset,"Headset, wireless dictation",phase 3: fan level 2 (strongest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",52.87,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",48.0
15,alander-2025,alander-2025:phase 3: noise level 5,Philips SpeechOne PSM6500 series,headset,"Headset, wireless dictation",phase 3: noise level 5,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.8,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.51
16,alander-2025,alander-2025:phase 3: noise level 6 (loudest),Philips SpeechOne PSM6500 series,headset,"Headset, wireless dictation",phase 3: noise level 6 (loudest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",12.25,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",7.29
17,alander-2025,alander-2025:phase 3: no distraction,Olympus RecMic DR-2200,handheld_dictation,"Handheld dictation, wired",phase 3: no distraction,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.37,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.0
18,alander-2025,alander-2025:phase 3: fan level 1,Olympus RecMic DR-2200,handheld_dictation,"Handheld dictation, wired",phase 3: fan level 1,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.59,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",1.27
19,alander-2025,alander-2025:phase 3: fan level 2 (strongest),Olympus RecMic DR-2200,handheld_dictation,"Handheld dictation, wired",phase 3: fan level 2 (strongest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",19.32,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",14.45
20,alander-2025,alander-2025:phase 3: noise level 5,Olympus RecMic DR-2200,handheld_dictation,"Handheld dictation, wired",phase 3: noise level 5,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.85,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.56
21,alander-2025,alander-2025:phase 3: noise level 6 (loudest),Olympus RecMic DR-2200,handheld_dictation,"Handheld dictation, wired",phase 3: noise level 6 (loudest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",8.44,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",3.48
22,alander-2025,alander-2025:phase 3: no distraction,Poly Blackwire C5210T,headset,"Headset, wired USB boom",phase 3: no distraction,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.14,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.77
23,alander-2025,alander-2025:phase 3: fan level 1,Poly Blackwire C5210T,headset,"Headset, wired USB boom",phase 3: fan level 1,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",96.15,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",92.83
24,alander-2025,alander-2025:phase 3: fan level 2 (strongest),Poly Blackwire C5210T,headset,"Headset, wired USB boom",phase 3: fan level 2 (strongest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",99.17,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",94.3
25,alander-2025,alander-2025:phase 3: noise level 5,Poly Blackwire C5210T,headset,"Headset, wired USB boom",phase 3: noise level 5,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.15,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.86
26,alander-2025,alander-2025:phase 3: noise level 6 (loudest),Poly Blackwire C5210T,headset,"Headset, wired USB boom",phase 3: noise level 6 (loudest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.96,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.0
27,alander-2025,alander-2025:phase 3: no distraction,Philips SpeechMike Premium Touch SMP3700/3800,handheld_dictation,"Handheld dictation, wired USB",phase 3: no distraction,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.78,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.41
28,alander-2025,alander-2025:phase 3: fan level 1,Philips SpeechMike Premium Touch SMP3700/3800,handheld_dictation,"Handheld dictation, wired USB",phase 3: fan level 1,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.32,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.0
29,alander-2025,alander-2025:phase 3: fan level 2 (strongest),Philips SpeechMike Premium Touch SMP3700/3800,handheld_dictation,"Handheld dictation, wired USB",phase 3: fan level 2 (strongest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",4.87,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.0
30,alander-2025,alander-2025:phase 3: noise level 5,Philips SpeechMike Premium Touch SMP3700/3800,handheld_dictation,"Handheld dictation, wired USB",phase 3: noise level 5,,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",3.29,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",0.0
31,alander-2025,alander-2025:phase 3: noise level 6 (loudest),Philips SpeechMike Premium Touch SMP3700/3800,handheld_dictation,"Handheld dictation, wired USB",phase 3: noise level 6 (loudest),,Dragon Medical One,"mean WER, average of stages 1 and 2 (Table 9)",9.52,,,,,,,Sanna Alander,2025,Comparing Microphones Used in Medical Dictation Based on Speech Recognition Accuracy and Usability,"Master's thesis, Aalto University",https://aaltodoc.aalto.fi/handle/123456789/135659,"Two speakers in stage 1, six in stage 2, two in phase 3; stages 2-3 replayed SpeechOne recordings through a Bose SoundLink Mini; distance not tested. Thesis is CC BY-NC-SA 4.0; only numeric results are cited here.",4.56
32,bradford-2022,bradford-2022:script,Saramonic SmartMic,plug_in_phone,Compact plug-in phone mic,"script reading, 5 ft",152,Google Cloud ASR,mean WER,10.7,25.0,USD,price in study,https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,,Type is general knowledge; paper says only that it used an AUX port,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",0.0
33,bradford-2022,bradford-2022:group-task,Saramonic SmartMic,plug_in_phone,Compact plug-in phone mic,"group task, overlapping speech, 5 ft",152,Google Cloud ASR,mean WER,58.1,,,,,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",5.4
34,bradford-2022,bradford-2022:script,Audio-Technica U891Rb,boundary,"Boundary, cardioid condenser","script reading, 5 ft",152,Google Cloud ASR,mean WER,11.2,349.0,USD,manufacturer list,https://www.audio-technica.com/en-us/u891rb,2026-11-23,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",0.5
35,bradford-2022,bradford-2022:group-task,Audio-Technica U891Rb,boundary,"Boundary, cardioid condenser","group task, overlapping speech, 5 ft",152,Google Cloud ASR,mean WER,52.7,,,,,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",0.0
36,bradford-2022,bradford-2022:script,Audio-Technica U891RbO,boundary,"Boundary, omni condenser","script reading, 5 ft",152,Google Cloud ASR,mean WER,11.2,319.0,USD,price in study,https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",0.5
37,bradford-2022,bradford-2022:group-task,Audio-Technica U891RbO,boundary,"Boundary, omni condenser","group task, overlapping speech, 5 ft",152,Google Cloud ASR,mean WER,53.0,,,,,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",0.3
38,bradford-2022,bradford-2022:script,Audio-Technica ATR2100x-USB,handheld_dynamic,"Handheld dynamic, cardioid USB/XLR","script reading, 5 ft",152,Google Cloud ASR,mean WER,11.5,99.0,USD,price in study,https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,,Discontinued,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",0.8
39,bradford-2022,bradford-2022:group-task,Audio-Technica ATR2100x-USB,handheld_dynamic,"Handheld dynamic, cardioid USB/XLR","group task, overlapping speech, 5 ft",152,Google Cloud ASR,mean WER,57.7,,,,,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",5.0
40,bradford-2022,bradford-2022:script,Blue Yeti,desktop_condenser,Desktop USB condenser (omni mode),"script reading, 5 ft",152,Google Cloud ASR,mean WER,11.7,139.99,USD,manufacturer list,https://www.logitechg.com/en-us/shop/p/yeti-premium-usb-microphone,2026-11-23,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",1.0
41,bradford-2022,bradford-2022:group-task,Blue Yeti,desktop_condenser,Desktop USB condenser (omni mode),"group task, overlapping speech, 5 ft",152,Google Cloud ASR,mean WER,61.3,,,,,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",8.6
42,bradford-2022,bradford-2022:script,MXL AC-404,boundary,"Boundary USB, 3-capsule, 180 degrees","script reading, 5 ft",152,Google Cloud ASR,mean WER,12.0,99.95,USD,price in study,https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",1.3
43,bradford-2022,bradford-2022:group-task,MXL AC-404,boundary,"Boundary USB, 3-capsule, 180 degrees","group task, overlapping speech, 5 ft",152,Google Cloud ASR,mean WER,60.2,,,,,,,"Mariah Bradford, Paige Hansen, Ross Beveridge, Nikhil Krishnaswamy, Nathaniel Blanchard",2022,A deep dive into microphone hardware for recording collaborative group work,Educational Data Mining 2022 (poster),https://educationaldatamining.org/edm2022/proceedings/2022.EDM-posters.65/index.html,"One ASR engine; differences within one SD; Blue Yeti used in omni mode. Authors' overall pick was the MXL AC-404, for noise robustness and price.",7.5
44,tran-2026,tran-2026:AWS General,Blue Yeti,desktop_condenser,Desktop USB condenser,"two-person conversation, quiet, AWS General",46,AWS General,median WER,16.7,139.99,USD,manufacturer list,https://www.logitechg.com/en-us/shop/p/yeti-premium-usb-microphone,2026-11-23,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
45,tran-2026,tran-2026:AWS General,Sony ICD-UX533,voice_recorder,Portable voice recorder,"two-person conversation, quiet, AWS General",46,AWS General,median WER,16.7,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
46,tran-2026,tran-2026:AWS General,Samsung Galaxy S7,phone,"Phone, built-in","two-person conversation, quiet, AWS General",46,AWS General,median WER,16.8,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.1
47,tran-2026,tran-2026:AWS General,MacBook Pro 2017,laptop,"Laptop, built-in","two-person conversation, quiet, AWS General",46,AWS General,median WER,16.7,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
48,tran-2026,tran-2026:AWS General,Aputure A.lav,lavalier,Lavalier / clip-on,"two-person conversation, quiet, AWS General",,AWS General,median WER,16.8,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.1
49,tran-2026,tran-2026:AWS Medical,Blue Yeti,desktop_condenser,Desktop USB condenser,"two-person conversation, quiet, AWS Medical",46,AWS Medical,median WER,16.8,139.99,USD,manufacturer list,https://www.logitechg.com/en-us/shop/p/yeti-premium-usb-microphone,2026-11-23,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
50,tran-2026,tran-2026:AWS Medical,Sony ICD-UX533,voice_recorder,Portable voice recorder,"two-person conversation, quiet, AWS Medical",46,AWS Medical,median WER,16.8,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
51,tran-2026,tran-2026:AWS Medical,Samsung Galaxy S7,phone,"Phone, built-in","two-person conversation, quiet, AWS Medical",46,AWS Medical,median WER,16.9,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.1
52,tran-2026,tran-2026:AWS Medical,MacBook Pro 2017,laptop,"Laptop, built-in","two-person conversation, quiet, AWS Medical",46,AWS Medical,median WER,16.8,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
53,tran-2026,tran-2026:AWS Medical,Aputure A.lav,lavalier,Lavalier / clip-on,"two-person conversation, quiet, AWS Medical",,AWS Medical,median WER,16.9,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.1
54,tran-2026,tran-2026:Azure Whisper,Blue Yeti,desktop_condenser,Desktop USB condenser,"two-person conversation, quiet, Azure Whisper",46,Azure Whisper,median WER,17.6,139.99,USD,manufacturer list,https://www.logitechg.com/en-us/shop/p/yeti-premium-usb-microphone,2026-11-23,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
55,tran-2026,tran-2026:Azure Whisper,Sony ICD-UX533,voice_recorder,Portable voice recorder,"two-person conversation, quiet, Azure Whisper",46,Azure Whisper,median WER,17.9,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.3
56,tran-2026,tran-2026:Azure Whisper,Samsung Galaxy S7,phone,"Phone, built-in","two-person conversation, quiet, Azure Whisper",46,Azure Whisper,median WER,17.7,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.1
57,tran-2026,tran-2026:Azure Whisper,MacBook Pro 2017,laptop,"Laptop, built-in","two-person conversation, quiet, Azure Whisper",46,Azure Whisper,median WER,17.6,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
58,tran-2026,tran-2026:Azure Whisper,Aputure A.lav,lavalier,Lavalier / clip-on,"two-person conversation, quiet, Azure Whisper",,Azure Whisper,median WER,17.9,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.3
59,tran-2026,tran-2026:Azure General,Blue Yeti,desktop_condenser,Desktop USB condenser,"two-person conversation, quiet, Azure General",46,Azure General,median WER,18.4,139.99,USD,manufacturer list,https://www.logitechg.com/en-us/shop/p/yeti-premium-usb-microphone,2026-11-23,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.1
60,tran-2026,tran-2026:Azure General,Sony ICD-UX533,voice_recorder,Portable voice recorder,"two-person conversation, quiet, Azure General",46,Azure General,median WER,18.3,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
61,tran-2026,tran-2026:Azure General,Samsung Galaxy S7,phone,"Phone, built-in","two-person conversation, quiet, Azure General",46,Azure General,median WER,18.3,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
62,tran-2026,tran-2026:Azure General,MacBook Pro 2017,laptop,"Laptop, built-in","two-person conversation, quiet, Azure General",46,Azure General,median WER,18.3,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
63,tran-2026,tran-2026:Azure General,Aputure A.lav,lavalier,Lavalier / clip-on,"two-person conversation, quiet, Azure General",,Azure General,median WER,18.5,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.2
64,tran-2026,tran-2026:Google General,Blue Yeti,desktop_condenser,Desktop USB condenser,"two-person conversation, quiet, Google General",46,Google General,median WER,19.7,139.99,USD,manufacturer list,https://www.logitechg.com/en-us/shop/p/yeti-premium-usb-microphone,2026-11-23,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.3
65,tran-2026,tran-2026:Google General,Sony ICD-UX533,voice_recorder,Portable voice recorder,"two-person conversation, quiet, Google General",46,Google General,median WER,19.4,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
66,tran-2026,tran-2026:Google General,Samsung Galaxy S7,phone,"Phone, built-in","two-person conversation, quiet, Google General",46,Google General,median WER,19.6,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.2
67,tran-2026,tran-2026:Google General,MacBook Pro 2017,laptop,"Laptop, built-in","two-person conversation, quiet, Google General",46,Google General,median WER,19.7,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.3
68,tran-2026,tran-2026:Google General,Aputure A.lav,lavalier,Lavalier / clip-on,"two-person conversation, quiet, Google General",,Google General,median WER,22.0,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",2.6
69,tran-2026,tran-2026:Google Medical,Blue Yeti,desktop_condenser,Desktop USB condenser,"two-person conversation, quiet, Google Medical",46,Google Medical,median WER,20.6,139.99,USD,manufacturer list,https://www.logitechg.com/en-us/shop/p/yeti-premium-usb-microphone,2026-11-23,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.8
70,tran-2026,tran-2026:Google Medical,Sony ICD-UX533,voice_recorder,Portable voice recorder,"two-person conversation, quiet, Google Medical",46,Google Medical,median WER,19.8,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.0
71,tran-2026,tran-2026:Google Medical,Samsung Galaxy S7,phone,"Phone, built-in","two-person conversation, quiet, Google Medical",46,Google Medical,median WER,20.0,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.2
72,tran-2026,tran-2026:Google Medical,MacBook Pro 2017,laptop,"Laptop, built-in","two-person conversation, quiet, Google Medical",46,Google Medical,median WER,20.0,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",0.2
73,tran-2026,tran-2026:Google Medical,Aputure A.lav,lavalier,Lavalier / clip-on,"two-person conversation, quiet, Google Medical",,Google Medical,median WER,25.0,,,,,,,"Brian D. Tran, Di Hu, Seungjun Kim, Yawen Guo, Ramya Mangu, Tera L. Reynolds, Jennifer Elston Lafata, Ming Tai-Seale, Kai Zheng",2026,Does Recording Hardware Matter for Clinical Speech Recognition? Evaluating ASR Performance Across Consumer Devices,"Preprint, not peer reviewed",https://pmc.ncbi.nlm.nih.gov/articles/PMC13228836/,"Two speakers. Across engines, pooled medians ranged 16.7-20.7%.",5.2
74,tipaksorn-2025,tipaksorn-2025:all,Table condensers,desktop_condenser,Desktop condenser,12-15 cm,13.5,"Whisper large-v3, zero-shot",WER,48.37,,,,,,,Pattara Tipaksorn et al.,2025,LOTUSDIS: A Thai far-field meeting corpus for robust conversational ASR,arXiv:2509.18722,https://arxiv.org/abs/2509.18722,Device and distance change together; not a dictation task.,0.0
75,tipaksorn-2025,tipaksorn-2025:all,Lavaliers,lavalier,Lavalier / clip-on,12-15 cm,13.5,"Whisper large-v3, zero-shot",WER,51.95,,,,,,,Pattara Tipaksorn et al.,2025,LOTUSDIS: A Thai far-field meeting corpus for robust conversational ASR,arXiv:2509.18722,https://arxiv.org/abs/2509.18722,Device and distance change together; not a dictation task.,3.58
76,tipaksorn-2025,tipaksorn-2025:all,JBL speaker device,speakerphone,Tabletop speaker mic,2 m,200,"Whisper large-v3, zero-shot",WER,59.9,,,,,,,Pattara Tipaksorn et al.,2025,LOTUSDIS: A Thai far-field meeting corpus for robust conversational ASR,arXiv:2509.18722,https://arxiv.org/abs/2509.18722,Device and distance change together; not a dictation task.,11.53
77,tipaksorn-2025,tipaksorn-2025:all,Bluetooth speakerphone (3 m),speakerphone,"Speakerphone, Bluetooth",3 m,300,"Whisper large-v3, zero-shot",WER,117.03,,,,,,,Pattara Tipaksorn et al.,2025,LOTUSDIS: A Thai far-field meeting corpus for robust conversational ASR,arXiv:2509.18722,https://arxiv.org/abs/2509.18722,Device and distance change together; not a dictation task.,68.66
78,tipaksorn-2025,tipaksorn-2025:all,Bluetooth speakerphone (10 m),speakerphone,"Speakerphone, Bluetooth",10 m,1000,"Whisper large-v3, zero-shot",WER,125.52,,,,,,,Pattara Tipaksorn et al.,2025,LOTUSDIS: A Thai far-field meeting corpus for robust conversational ASR,arXiv:2509.18722,https://arxiv.org/abs/2509.18722,Device and distance change together; not a dictation task.,77.15
79,rosehill-2025,rosehill-2025:all,OnePlus Nord 3 5G,phone,"Phone, built-in",quiet,,OpenAI whisper-1,"WER, single take",4.13,,,,,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",0.0
80,rosehill-2025,rosehill-2025:all,UGreen CM564,gooseneck,Gooseneck USB,30 cm,30,OpenAI whisper-1,"WER, single take",4.44,18.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",0.31
81,rosehill-2025,rosehill-2025:all,Audio-Technica ATR4697,boundary,Boundary,80 cm,80,OpenAI whisper-1,"WER, single take",4.76,45.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",0.63
82,rosehill-2025,rosehill-2025:all,EMEET conference speakerphone,speakerphone,Speakerphone,quiet,,OpenAI whisper-1,"WER, single take",5.08,40.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",0.95
83,rosehill-2025,rosehill-2025:all,Samson Q2U,handheld_dynamic,"Handheld dynamic, cardioid USB/XLR",30 cm,30,OpenAI whisper-1,"WER, single take",5.4,70.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.27
84,rosehill-2025,rosehill-2025:all,OnePlus Nord 3 5G,phone,"Phone, built-in",Voicenotes MP3,,OpenAI whisper-1,"WER, single take",5.4,,,,,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.27
85,rosehill-2025,rosehill-2025:all,Audio-Technica ATR4697,boundary,Boundary,30 cm,30,OpenAI whisper-1,"WER, single take",5.4,45.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.27
86,rosehill-2025,rosehill-2025:all,Jabra Speak 510,speakerphone,Speakerphone,quiet,,OpenAI whisper-1,"WER, single take",5.4,110.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.27
87,rosehill-2025,rosehill-2025:all,Logitech C925e,webcam,"Webcam, built-in",30 cm,30,OpenAI whisper-1,"WER, single take",5.4,75.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.27
88,rosehill-2025,rosehill-2025:all,Maono Elf,lavalier,Lavalier / clip-on,quiet,,OpenAI whisper-1,"WER, single take",5.4,25.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.27
89,rosehill-2025,rosehill-2025:all,Logitech H390,headset,"Headset, wired USB boom",quiet,,OpenAI whisper-1,"WER, single take",5.71,30.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.58
90,rosehill-2025,rosehill-2025:all,OnePlus Nord 3 5G,phone,"Phone, built-in",ASR HQ recording,,OpenAI whisper-1,"WER, single take",5.71,,,,,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.58
91,rosehill-2025,rosehill-2025:all,Yealink BH72,headset,"Headset, wireless",vendor dongle,,OpenAI whisper-1,"WER, single take",6.03,160.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.9
92,rosehill-2025,rosehill-2025:all,Yealink BH72,headset,"Headset, wireless",generic Bluetooth adapter,,OpenAI whisper-1,"WER, single take",6.03,160.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.9
93,rosehill-2025,rosehill-2025:all,OnePlus Nord 3 5G,phone,"Phone, built-in",noisy market,,OpenAI whisper-1,"WER, single take",6.03,,,,,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.9
94,rosehill-2025,rosehill-2025:all,Sony ICD-UX570,voice_recorder,Portable voice recorder,MP3,,OpenAI whisper-1,"WER, single take",6.03,100.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",1.9
95,rosehill-2025,rosehill-2025:all,Audio-Technica ATR4750-USB,gooseneck,"Gooseneck USB, omni",quiet,,OpenAI whisper-1,"WER, single take",6.35,55.0,USD,author's approximate price,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,,,Daniel Rosehill,2025,One-Shot Transcription Microphone Eval,Personal benchmark,https://github.com/danielrosehill/One-Shot-Transcription-Microphone-Eval,"One take per condition; one word is 0.32 points, so the 4.13-6.35% spread is about seven words. An anecdotal data point, not a ranking.",2.22
|