Spaces:
Sleeping
Sleeping
File size: 10,750 Bytes
aec7019 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 | """现场数据接入配置:持久化、校验、密码隔离与默认点表。
配置文件放在 /data 卷中,容器重启后保留。OPC 密码单独存放且不通过
GET 接口返回,避免配置页面或日志意外泄露。
"""
from __future__ import annotations
import json
import os
import re
import shutil
import tempfile
from datetime import datetime, timezone
from functools import lru_cache
from pathlib import Path
from typing import Literal, Optional
from pydantic import BaseModel, Field, field_validator, model_validator
DataType = Literal["Boolean", "Int16", "Int32", "UInt16", "UInt32", "Float", "Double", "String"]
SourceMode = Literal["simulation", "opcua"]
class TagMapping(BaseModel):
key: str = Field(min_length=1, max_length=80)
label: str = Field(min_length=1, max_length=120)
node_id: str = Field(default="", max_length=300)
data_type: DataType = "Double"
unit: str = Field(default="", max_length=30)
scale: float = 1.0
offset: float = 0.0
enabled: bool = True
required: bool = False
writable: bool = False
@field_validator("key")
@classmethod
def validate_key(cls, value: str) -> str:
value = value.strip()
if not re.fullmatch(r"[A-Za-z][A-Za-z0-9_.-]*", value):
raise ValueError("点位键只能包含字母、数字、点、横线和下划线,并以字母开头")
return value
@field_validator("node_id")
@classmethod
def normalize_node_id(cls, value: str) -> str:
return value.strip()
class OpcConnectionConfig(BaseModel):
endpoint: str = "opc.tcp://opcua-sim:4840/biditech/server/"
security_policy: Literal[
"None", "Basic256Sha256", "Aes128_Sha256_RsaOaep", "Aes256_Sha256_RsaPss"
] = "None"
security_mode: Literal["None", "Sign", "SignAndEncrypt"] = "None"
username: str = Field(default="", max_length=120)
certificate_path: str = Field(default="", max_length=300)
private_key_path: str = Field(default="", max_length=300)
server_certificate_path: str = Field(default="", max_length=300)
sampling_interval_ms: int = Field(default=1000, ge=200, le=60000)
timeout_s: float = Field(default=5.0, ge=1.0, le=30.0)
reconnect_interval_s: float = Field(default=5.0, ge=1.0, le=300.0)
password_configured: bool = False
@field_validator("endpoint")
@classmethod
def validate_endpoint(cls, value: str) -> str:
value = value.strip()
if not value.startswith("opc.tcp://"):
raise ValueError("OPC UA 地址必须以 opc.tcp:// 开头")
return value
@model_validator(mode="after")
def validate_security(self):
if self.security_policy == "None" and self.security_mode != "None":
raise ValueError("安全策略为 None 时,安全模式也必须为 None")
if self.security_policy != "None":
if self.security_mode == "None":
raise ValueError("启用安全策略后必须选择 Sign 或 SignAndEncrypt")
if not self.certificate_path or not self.private_key_path:
raise ValueError("启用安全策略后必须填写客户端证书和私钥路径")
return self
class OpcConnectionUpdate(OpcConnectionConfig):
password: Optional[str] = Field(default=None, max_length=300, exclude=True)
class IntegrationConfig(BaseModel):
revision: int = 1
updated_at: str
source_mode: SourceMode = "simulation"
connection: OpcConnectionConfig = Field(default_factory=OpcConnectionConfig)
tags: list[TagMapping]
@model_validator(mode="after")
def validate_tags(self):
keys = [tag.key for tag in self.tags]
if len(keys) != len(set(keys)):
raise ValueError("点位键不能重复")
enabled_ids = [tag.node_id for tag in self.tags if tag.enabled and tag.node_id]
if len(enabled_ids) != len(set(enabled_ids)):
raise ValueError("已启用点位的 NodeId 不能重复")
missing = [tag.label for tag in self.tags if tag.required and tag.enabled and not tag.node_id]
if missing:
raise ValueError(f"必需点位缺少 NodeId:{', '.join(missing)}")
return self
class IntegrationConfigUpdate(BaseModel):
source_mode: SourceMode
connection: OpcConnectionUpdate
tags: list[TagMapping]
def _tag(
key: str,
label: str,
node_id: str,
data_type: DataType = "Double",
unit: str = "",
*,
required: bool = False,
writable: bool = False,
) -> TagMapping:
return TagMapping(
key=key,
label=label,
node_id=node_id,
data_type=data_type,
unit=unit,
required=required,
writable=writable,
)
def default_tags() -> list[TagMapping]:
base = "ns=2;s=PumpStation1."
tags = [
_tag("level", "集水井液位", base + "Level", unit="m", required=True),
_tag("totalFlow", "总管瞬时流量", base + "TotalFlow", unit="m³/h", required=True),
_tag("totalPower", "泵组总有功功率", base + "TotalPower", unit="kW"),
_tag("pressure", "总管压力", base + "Pressure", unit="MPa"),
_tag("writeEnable", "控制写使能", base + "WriteEnable", "Boolean", writable=True),
_tag("heartbeat", "控制心跳", base + "Heartbeat", "UInt32", writable=True),
]
for pid in range(1, 6):
prefix = base + f"Pump{pid}."
tags.extend(
[
_tag(f"pump{pid}.status", f"{pid}号泵运行状态", prefix + "Status", "Int32", required=True),
_tag(f"pump{pid}.freq", f"{pid}号泵运行频率", prefix + "Freq", unit="Hz"),
_tag(f"pump{pid}.current", f"{pid}号泵电流", prefix + "Current", unit="A"),
_tag(f"pump{pid}.power", f"{pid}号泵有功功率", prefix + "Power", unit="kW"),
_tag(f"pump{pid}.runHours", f"{pid}号泵累计运行时间", prefix + "RunHours", unit="h"),
_tag(
f"pump{pid}.freqSet",
f"{pid}号泵频率设定",
prefix + "FreqSet",
unit="Hz",
writable=True,
),
_tag(f"pump{pid}.cmd", f"{pid}号泵启停指令", prefix + "Cmd", "Int32", writable=True),
]
)
return tags
def utc_now() -> str:
return datetime.now(timezone.utc).isoformat()
def default_config() -> IntegrationConfig:
config = IntegrationConfig(updated_at=utc_now(), tags=default_tags())
default_endpoint = os.environ.get("BIDITECH_DEFAULT_OPCUA_ENDPOINT", "").strip()
if default_endpoint:
config.connection.endpoint = default_endpoint
config.source_mode = "opcua"
return config
class IntegrationConfigStore:
def __init__(self, config_path: Path, secret_path: Path):
self.config_path = Path(config_path)
self.secret_path = Path(secret_path)
def _password(self) -> str:
env_password = os.environ.get("OPCUA_PASSWORD")
if env_password is not None:
return env_password
if not self.secret_path.exists():
return ""
try:
payload = json.loads(self.secret_path.read_text(encoding="utf-8"))
return str(payload.get("password") or "")
except (OSError, ValueError, TypeError):
return ""
def get_password(self) -> str:
return self._password()
def load(self) -> IntegrationConfig:
if not self.config_path.exists():
config = default_config()
else:
config = IntegrationConfig.model_validate_json(
self.config_path.read_text(encoding="utf-8")
)
config.connection.password_configured = bool(self._password())
return config
def _atomic_json_write(self, path: Path, payload: dict) -> None:
path.parent.mkdir(parents=True, exist_ok=True)
fd, temp_name = tempfile.mkstemp(prefix=path.name + ".", suffix=".tmp", dir=path.parent)
try:
with os.fdopen(fd, "w", encoding="utf-8") as handle:
json.dump(payload, handle, ensure_ascii=False, indent=2)
handle.write("\n")
handle.flush()
os.fsync(handle.fileno())
os.replace(temp_name, path)
finally:
if os.path.exists(temp_name):
os.unlink(temp_name)
def save(self, update: IntegrationConfigUpdate) -> IntegrationConfig:
current = self.load()
password = update.connection.password
if password is not None:
self._atomic_json_write(self.secret_path, {"password": password})
try:
os.chmod(self.secret_path, 0o600)
except OSError:
pass
connection_payload = update.connection.model_dump(exclude={"password"})
connection_payload["password_configured"] = bool(
password if password is not None else self._password()
)
saved = IntegrationConfig(
revision=current.revision + 1,
updated_at=utc_now(),
source_mode=update.source_mode,
connection=OpcConnectionConfig(**connection_payload),
tags=update.tags,
)
if self.config_path.exists():
backup = self.config_path.with_suffix(self.config_path.suffix + ".bak")
shutil.copy2(self.config_path, backup)
self._atomic_json_write(self.config_path, saved.model_dump())
return self.load()
def reset(self) -> IntegrationConfig:
current = self.load()
reset_config = default_config()
reset_config.revision = current.revision + 1
if self.config_path.exists():
backup = self.config_path.with_suffix(self.config_path.suffix + ".bak")
shutil.copy2(self.config_path, backup)
self._atomic_json_write(self.config_path, reset_config.model_dump())
return self.load()
@lru_cache
def get_config_store() -> IntegrationConfigStore:
# Containers persist configuration in /data. Direct Windows runs use a
# project-local writable directory instead of the protected \data root.
default_data_dir = (
Path(__file__).resolve().parents[1] / "data"
if os.name == "nt"
else Path("/data")
)
config_path = Path(
os.environ.get(
"BIDITECH_INTEGRATION_CONFIG",
str(default_data_dir / "integration_config.json"),
)
)
secret_path = Path(
os.environ.get(
"BIDITECH_OPCUA_SECRET",
str(default_data_dir / "opcua_secret.json"),
)
)
return IntegrationConfigStore(config_path, secret_path)
|