pump / backend /app /models /parallel.py
Codex
Deploy efficiency estimate fix cf55248
aec7019
Raw History Blame Contribute Delete
5.38 kB
"""并联泵组模型(复用文档 2.1 PumpGroupParallelModel 规格)。
- 系统管阻特性:H = H_static + S·Q_total²。
- 并联工作点:在扬程 H 处各泵流量相加 = 系统流量,brentq 求解耦合工作点。
- SEC(单位供水能耗,kWh/m³)= 总输入功率 / 总流量。
"""
from __future__ import annotations
from dataclasses import dataclass, field
from scipy.optimize import brentq
from .pump_curve import PumpCurveModel
@dataclass
class OperatingPoint:
Q_total: float # 总流量 m³/h
H: float # 工作扬程 m
P_total: float # 总输入功率 kW
spec_energy: float # SEC kWh/m³
per_pump: dict # {pump_id: {"Q":, "H":, "P":, "eta":, "freq":}}
feasible: bool = True
reason: str | None = None
residual: float = 0.0
@dataclass
class PumpGroupParallelModel:
pumps: dict # {id: PumpCurveModel}
static_head: float = 12.0
pipe_resistance: float = 2.6e-4 # S,Q 单位 m³/h
level_ref: float | None = None # 静扬程参考液位 (m);给了则扬程随液位变化
def static_at(self, level: float | None) -> float:
"""无出口压力表时的几何静扬程估计:液位越低静扬程越大。
Hst(level) = static_head + (level_ref - level);level 或 level_ref 缺省则取 static_head。"""
if level is None or self.level_ref is None:
return self.static_head
return self.static_head + (self.level_ref - level)
def system_head(self, Q_total: float, level: float | None = None) -> float:
return self.static_at(level) + self.pipe_resistance * Q_total * Q_total
def system_flow(self, H: float, level: float | None = None) -> float:
"""系统曲线反解:给定扬程对应的输送流量。"""
hst = self.static_at(level)
if H <= hst:
return 0.0
return ((H - hst) / self.pipe_resistance) ** 0.5
def group_flow_at_head(self, H: float, active: dict) -> float:
"""active={id: freq}:给定扬程 H,各在运泵流量之和。"""
return sum(self.pumps[pid].flow_at_head(H, f) for pid, f in active.items())
def solve(self, active: dict, level: float | None = None) -> OperatingPoint:
"""求并联工作点。active={pump_id: freq_hz}。level 给定则按液位估计静扬程
(无出口压力表时的扬程估计)。无在运泵返回零点。"""
hst = self.static_at(level)
if not active:
return OperatingPoint(0.0, hst, 0.0, 0.0, {})
# 在扬程 H 上求解:群泵流量(H) == 系统流量(H)
max_shutoff = max(self.pumps[pid].shutoff_head(f) for pid, f in active.items())
lo, hi = hst + 1e-6, max_shutoff - 1e-6
if hi <= lo: # 泵抬不动静扬程 → 无流量
return OperatingPoint(
0.0, hst, 0.0, 0.0, {}, feasible=False,
reason="pump_head_below_static_head",
)
def resid(H):
return self.group_flow_at_head(H, active) - self.system_flow(H, level)
# resid 在 lo 处 >0(低扬程群泵能出更多流量),hi 处 <0
r_lo, r_hi = resid(lo), resid(hi)
if r_lo * r_hi > 0:
# 仅在区间内存在真实变号时才接受根;不能拿边界点冒充工作点。
H = self._scan_root(resid, lo, hi)
if H is None:
return OperatingPoint(
0.0, hst, 0.0, 0.0, {}, feasible=False,
reason="no_pump_system_curve_intersection",
residual=float(min(abs(r_lo), abs(r_hi))),
)
else:
H = float(brentq(resid, lo, hi, xtol=1e-3))
per_pump, P_total, Q_total = {}, 0.0, 0.0
operating_range_ok = True
for pid, f in active.items():
pm = self.pumps[pid]
q = pm.flow_at_head(H, f)
if q < pm.q_min(f) - 1e-6 or q > pm.q_max(f) + 1e-6:
operating_range_ok = False
p = pm.input_power(q, f)
p = 0.0 if p != p else p # nan → 0
per_pump[pid] = {"Q": q, "H": H, "P": p, "eta": pm.eta(q, f), "freq": f}
Q_total += q
P_total += p
sec = P_total / Q_total if Q_total > 1e-6 else 0.0
curve_residual = Q_total - self.system_flow(H, level)
tolerance = max(0.5, Q_total * 1e-3)
feasible = (abs(curve_residual) <= tolerance and Q_total > 1e-6
and operating_range_ok)
return OperatingPoint(
Q_total, H, P_total, sec, per_pump,
feasible=feasible,
reason=(None if feasible else
"outside_verified_pump_curve_range" if not operating_range_ok else
"pump_system_curve_residual_too_large"),
residual=float(curve_residual),
)
@staticmethod
def _scan_root(fn, lo, hi, n=200):
import numpy as np
xs = np.linspace(lo, hi, n)
prev_x, prev_y = xs[0], fn(xs[0])
for x in xs[1:]:
y = fn(x)
if prev_y == 0:
return float(prev_x)
if prev_y * y < 0:
return float(brentq(fn, prev_x, x, xtol=1e-3))
prev_x, prev_y = x, y
return None