pump / backend /tests /test_curve.py
Codex
Deploy efficiency estimate fix cf55248
aec7019
Raw History Blame Contribute Delete
2.22 kB
import numpy as np
from app.models.pump_curve import PumpCurveModel
Q = [0, 40, 80, 120, 150, 180, 210]
H = [58.0, 56.5, 53.0, 47.0, 42.5, 36.0, 27.0]
E = [0.0, 0.42, 0.66, 0.79, 0.82, 0.78, 0.66]
def make():
return PumpCurveModel(1, Q, H, E, freq_nominal=50.0)
def test_head_monotonic_decreasing():
pm = make()
heads = [pm.head(q, 50.0) for q in range(0, 210, 10)]
# H-Q 在工作段应整体递减,不出现负值/振荡(not-a-knot 边界的价值)
assert all(heads[i] >= heads[i + 1] - 1e-6 for i in range(len(heads) - 1))
assert min(heads) > 0
def test_affinity_laws():
pm = make()
# 相似定律:40Hz 下 shutoff head ≈ 50Hz shutoff × (40/50)²
r = 40.0 / 50.0
assert abs(pm.shutoff_head(40.0) - pm.shutoff_head(50.0) * r * r) < 1e-6
# Q∝f:50Hz 的 BEP 流量 × r ≈ 40Hz BEP 流量
assert abs(pm.bep_flow(40.0) - pm.bep_flow(50.0) * r) < 1e-6
def test_flow_at_head_inverse():
pm = make()
q = 120.0
h = pm.head(q, 50.0)
q_back = pm.flow_at_head(h, 50.0)
assert abs(q_back - q) < 1.0 # 反解误差 < 1 m³/h
def test_bep_and_efficiency():
pm = make()
assert 130 < pm.bep_flow(50.0) < 170 # BEP 落在 150 附近
assert 0.75 < pm.eta_max <= 0.85
# 低速效率修正使 30Hz 峰值效率低于 50Hz
assert pm.eta(pm.bep_flow(30.0), 30.0) < pm.eta(pm.bep_flow(50.0), 50.0)
def test_input_power_positive():
pm = make()
p = pm.input_power(150.0, 50.0)
assert 15 < p < 45 # 45kW 泵在该工况点(150 m³/h,42.5m)的输入功率量级
def test_from_poly_matches_quadratic_and_gaussian():
# V1.0 参数形式:H=a0+a1Q+a2Q²,η 高斯
a0, a1, a2 = 58.0, 0.02, -7.0e-4
eta_max, q_bep, sigma = 0.82, 150.0, 95.0
pm = PumpCurveModel.from_poly(9, a0, a1, a2, q_max=210, eta_max=eta_max,
q_bep=q_bep, eta_sigma=sigma, freq_nominal=50.0)
# 扬程应还原二次多项式
for q in (0.0, 60.0, 150.0, 200.0):
assert abs(pm.head(q, 50.0) - (a0 + a1 * q + a2 * q * q)) < 0.5
# 高斯效率峰值落在 q_bep 附近
assert abs(pm.bep_flow(50.0) - q_bep) < 12
assert abs(pm.eta_max - eta_max) < 0.02