CHRISv1.py CHANGED
@@ -1,9 +1,7 @@
1
  import math
2
  import numpy as np
3
- from flask import Flask, render_template, request, Response
4
-
5
  from matplotlib.backends.backend_agg import FigureCanvasAgg as FigureCanvas
6
- from matplotlib.figure import Figure
7
  import matplotlib
8
  matplotlib.use('Agg')
9
  import matplotlib.pyplot as plt
@@ -13,7 +11,6 @@ import base64
13
  def sigfigs(number, n):
14
  return round(number, n - int(math.floor(math.log10(math.fabs(number)))) - 1)
15
 
16
-
17
  # Named polymer matrices and category numbers
18
  nPoly = 20
19
  PolyData = np.zeros((nPoly,), dtype=[('name', 'a75'), ('Category', 'i')])
 
1
  import math
2
  import numpy as np
3
+ from flask import Flask, render_template, request
 
4
  from matplotlib.backends.backend_agg import FigureCanvasAgg as FigureCanvas
 
5
  import matplotlib
6
  matplotlib.use('Agg')
7
  import matplotlib.pyplot as plt
 
11
  def sigfigs(number, n):
12
  return round(number, n - int(math.floor(math.log10(math.fabs(number)))) - 1)
13
 
 
14
  # Named polymer matrices and category numbers
15
  nPoly = 20
16
  PolyData = np.zeros((nPoly,), dtype=[('name', 'a75'), ('Category', 'i')])
static/exposure_COU.html ADDED
@@ -0,0 +1,33 @@
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
+ <h1 id="context-of-use-cou">Context of Use (COU)</h1>
2
+ <p>The bulk chemical module of the CHemical RISk calculator (CHRIS) is (proposed to be) qualified to conduct screening level risk assessments to aid in the biocompatibility evaluation of bulk additives and impurities in polymeric medical device components. These assessments can assist device manufacturers by providing instantaneous feedback on whether the presence of the bulk chemical would require additional justification and/or testing to demonstrate acceptable biological risk. The output of CHRIS is a conservative margin of safety (MOS = toxicological safety limit ÷ exposure dose) value for a bulk chemical contained within a polymeric medical device component. Based on the MOS value, the calculator determines if further assessment of one or more biocompatibility endpoints is necessary for the specific chemical.</p>
3
+ <p>Because CHRIS only addresses compounds with a distribution that is macroscopically homogeneous within the matrix, the tool can only be used to assess bulk additives and impurities. Therefore, only compounds that are introduced either intentionally or unintentionally during synthesis (e.g. residual monomers and oligomers, catalysts, initiators) or compounding (e.g. stabilizers, antioxidants, plasticizers) are within scope. Surface residuals from processing, cleaning, and sterilization are excluded. Also, CHRIS requires the total amount of the chemical to be established in advance, e.g. based on a certificate of analysis. Further CHRIS only addresses individual chemicals; therefore, a favorable outcome by CHRIS does not imply acceptable biological risk for the final finished form of a medical device. CHRIS is also not intended to establish device classification or identify biocompatibility requirements.</p>
4
+ <p>CHRIS provides clinically relevant, yet still conservative, exposure dose estimates using a physics-based transport model for polymeric systems where transport data are available to support the use of the model. The model applies worst-case boundary conditions for release of a substance from the polymer matrix and is based on four (4) primary assumptions:</p>
5
+ <ol type="1">
6
+ <li>The clinical use environment does not cause the polymer matrix to swell or degrade.</li>
7
+ <li>The chemical is homogeneously distributed throughout the polymer.</li>
8
+ <li>The total amount of the chemical is present in dilute concentrations (≤ 2 m/v %).</li>
9
+ <li>Any particles/aggregates of the chemical present in the polymer are much smaller than the smallest component dimension (≤ 50x).</li>
10
+ </ol>
11
+ <p>While these assumptions are typically valid for bulk additives and impurities in biostable polymers, users of CHRIS must confirm conformance to the underlying assumptions or provide supporting justification to ensure compliance for a given system. Further, CHRIS only enables system specific exposure estimates for nineteen (19) polymeric systems that are generally biostable (non-swelling and non-degrading). These polymers are listed below. To estimate chemical release based on the model, the diffusion coefficient of the chemical in the polymer matrix must be specified. For the nineteen (19) listed polymeric systems, a worst-case (upper bound) diffusion coefficient, as a function of molecular weight, has been established based on data from the literature. For polymer matrices that are not included in this list, CHRIS assigns an ultra-conservative diffusion coefficient that assumes the polymer has the properties of water. Note that the worst-case diffusion coefficient is only defined over a molecular weight range of 100 to 1100 g/mol. Therefore, for substances with a molecular weight &gt; 1100 g/mol, the value of the diffusion coefficient assuming a molecular weight of 1100 g/mol can be used as a conservative value; for substances with a molecular weight &lt; 100 g/mol, CHRIS currently cannot be used to estimate exposure.</p>
12
+ <ul>
13
+ <li>Silicone</li>
14
+ <li>Polyethylene (density &lt;= 0.94 g/cm<sup>3</sup>)</li>
15
+ <li>Polyethylene (density &gt; 0.94 g/cm<sup>3</sup>)</li>
16
+ <li>Polyethylene terephthalate</li>
17
+ <li>Polyurethane (polyether)</li>
18
+ <li>Polycarbonate</li>
19
+ <li>Polyoxymethylene</li>
20
+ <li>Poly(methyl methacrylate)</li>
21
+ <li>Acrylonitrile butadiene styrene</li>
22
+ <li>Polyether block amide</li>
23
+ <li>Polyamide</li>
24
+ <li>Polystyrene</li>
25
+ <li>Polyvinyl chloride</li>
26
+ <li>Polytetrafluoroethylene</li>
27
+ <li>Polypropylene</li>
28
+ <li>Polyvinyl acetate</li>
29
+ <li>Polybutylene terephthalate</li>
30
+ <li>Polyetheretherketone</li>
31
+ <li>Fluorinated ethylene propylene</li>
32
+ </ul>
33
+ <p>In the absence of adequate toxicological and exposure data for a chemical in a polymeric matrix, a toxicological risk assessment can be conducted for systemic biocompatibility endpoints by comparing the exposure estimate to an appropriate threshold of toxicological concern (TTC). This is the approach used by CHRIS in this module. The TTC values are based on systemic toxicity, thus CHRIS can address acute systemic toxicity, subacute/subchronic toxicity, genotoxicity, carcinogenicity, and reproductive and developmental toxicity. It does not, however, address cytotoxicity, sensitization, irritation, hemocompatibility, material mediated pyrogenicity, or implantation. Therefore, an MOS &gt;= 1 implies the chemical will not raise a safety concern with respect to only the systemic biocompatibility endpoints, provided the chemical is not within the cohort of concern, which is reflected in the output of CHRIS.</p>
static/exposure_COU.md ADDED
@@ -0,0 +1,36 @@
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
+ # Context of Use (COU)
2
+
3
+ The bulk chemical module of the CHemical RISk calculator (CHRIS) is (proposed to be) qualified to conduct screening level risk assessments to aid in the biocompatibility evaluation of bulk additives and impurities in polymeric medical device components. These assessments can assist device manufacturers by providing instantaneous feedback on whether the presence of the bulk chemical would require additional justification and/or testing to demonstrate acceptable biological risk. The output of CHRIS is a conservative margin of safety (MOS = toxicological safety limit ÷ exposure dose) value for a bulk chemical contained within a polymeric medical device component. Based on the MOS value, the calculator determines if further assessment of one or more biocompatibility endpoints is necessary for the specific chemical.
4
+
5
+ Because CHRIS only addresses compounds with a distribution that is macroscopically homogeneous within the matrix, the tool can only be used to assess bulk additives and impurities. Therefore, only compounds that are introduced either intentionally or unintentionally during synthesis (e.g. residual monomers and oligomers, catalysts, initiators) or compounding (e.g. stabilizers, antioxidants, plasticizers) are within scope. Surface residuals from processing, cleaning, and sterilization are excluded. Also, CHRIS requires the total amount of the chemical to be established in advance, e.g. based on a certificate of analysis. Further CHRIS only addresses individual chemicals; therefore, a favorable outcome by CHRIS does not imply acceptable biological risk for the final finished form of a medical device. CHRIS is also not intended to establish device classification or identify biocompatibility requirements.
6
+
7
+ CHRIS provides clinically relevant, yet still conservative, exposure dose estimates using a physics-based transport model for polymeric systems where transport data are available to support the use of the model. The model applies worst-case boundary conditions for release of a substance from the polymer matrix and is based on four (4) primary assumptions:
8
+
9
+ 1. The clinical use environment does not cause the polymer matrix to swell or degrade.
10
+ 1. The chemical is homogeneously distributed throughout the polymer.
11
+ 1. The total amount of the chemical is present in dilute concentrations (&le; 2 m/v %).
12
+ 1. Any particles/aggregates of the chemical present in the polymer are much smaller than the smallest component dimension (&le; 50x).
13
+
14
+ While these assumptions are typically valid for bulk additives and impurities in biostable polymers, users of CHRIS must confirm conformance to the underlying assumptions or provide supporting justification to ensure compliance for a given system. Further, CHRIS only enables system specific exposure estimates for nineteen (19) polymeric systems that are generally biostable (non-swelling and non-degrading). These polymers are listed below. To estimate chemical release based on the model, the diffusion coefficient of the chemical in the polymer matrix must be specified. For the nineteen (19) listed polymeric systems, a worst-case (upper bound) diffusion coefficient, as a function of molecular weight, has been established based on data from the literature. For polymer matrices that are not included in this list, CHRIS assigns an ultra-conservative diffusion coefficient that assumes the polymer has the properties of water. Note that the worst-case diffusion coefficient is only defined over a molecular weight range of 100 to 1100 g/mol. Therefore, for substances with a molecular weight > 1100 g/mol, the value of the diffusion coefficient assuming a molecular weight of 1100 g/mol can be used as a conservative value; for substances with a molecular weight < 100 g/mol, CHRIS currently cannot be used to estimate exposure.
15
+
16
+ * Silicone
17
+ * Polyethylene (density <= 0.94 g/cm<sup>3</sup>)
18
+ * Polyethylene (density > 0.94 g/cm<sup>3</sup>)
19
+ * Polyethylene terephthalate
20
+ * Polyurethane (polyether)
21
+ * Polycarbonate
22
+ * Polyoxymethylene
23
+ * Poly(methyl methacrylate)
24
+ * Acrylonitrile butadiene styrene
25
+ * Polyether block amide
26
+ * Polyamide
27
+ * Polystyrene
28
+ * Polyvinyl chloride
29
+ * Polytetrafluoroethylene
30
+ * Polypropylene
31
+ * Polyvinyl acetate
32
+ * Polybutylene terephthalate
33
+ * Polyetheretherketone
34
+ * Fluorinated ethylene propylene
35
+
36
+ In the absence of adequate toxicological and exposure data for a chemical in a polymeric matrix, a toxicological risk assessment can be conducted for systemic biocompatibility endpoints by comparing the exposure estimate to an appropriate threshold of toxicological concern (TTC). This is the approach used by CHRIS in this module. The TTC values are based on systemic toxicity, thus CHRIS can address acute systemic toxicity, subacute/subchronic toxicity, genotoxicity, carcinogenicity, and reproductive and developmental toxicity. It does not, however, address cytotoxicity, sensitization, irritation, hemocompatibility, material mediated pyrogenicity, or implantation. Therefore, an MOS >= 1 implies the chemical will not raise a safety concern with respect to only the systemic biocompatibility endpoints, provided the chemical is not within the cohort of concern, which is reflected in the output of CHRIS.
templates/exposure_index.html CHANGED
@@ -53,7 +53,7 @@ body {font-family: Arial, Helvetica, sans-serif;}
53
  </head>
54
 
55
  <header>
56
- <h2>CHemical RISk calculator (CHRIS) - Bulk chemical exposure</h2>
57
  </header>
58
 
59
  <p><strong>Disclaimer: This module only addresses risk associated with the bulk chemicals of known initial quantity.
@@ -61,6 +61,9 @@ body {font-family: Arial, Helvetica, sans-serif;}
61
  Further, a successful evaluation does not address local biocompatibility endpoints, and therefore additional testing
62
  may be needed despite a positive outcome. </strong></p>
63
 
 
 
 
64
  <body>
65
 
66
  <form method="POST">
@@ -163,7 +166,7 @@ Density (g/cm<sup>3</sup>): <input name="density" id="density" step="any" value=
163
  <div class="modal-body">
164
  <p><em>Exposed surface area</em> - Enter the patient contacting surface area of the component being evaluated in square centimeters.
165
  This includes both direct and indirect patient contact.</p>
166
- <p><em>Exposure type</em> - Select the appropriate exposure category: > 30 days = permanent, > 24 hours - 30 days = prolonged, &#8804; 24 hours = limited.
167
  For limited exposures (&#8804; 24 hours), please enter the maximum exposure time in hours.</p>
168
  </div>
169
  <div class="modal-footer">
@@ -198,11 +201,28 @@ Density (g/cm<sup>3</sup>): <input name="density" id="density" step="any" value=
198
  <h4 class="modal-title">Assumptions</h4>
199
  </div>
200
  <div class="modal-body">
201
- <p>The exposure model relies on assumptions that are typically valid for bulk solutes in polymeric device components. However, if any of the assumptions are violated the exposure calculation may not remain protective. Therefore, if the output of CHRIS is used to support a submission to CDRH, users must confirm conformance to the underlying assumptions or provide supporting justification. Examples of considerations when confirming conformance are provided below:</p>
202
- <p><em>Biostability of the matrix - </em> While many of the matrices listed within CHRIS will not appreciably swell or degrade in any physiological environment, this can not be generalized. For example, silicones may swell in lipid-rich environments. Chemical compatibility of the polymer matrix with the use environment can be assessed based on historical use and/or evaluation of swelling and/or degradation propensity in physiologically relevant media. </p>
203
- <p><em>Particle/aggregate size and distribution - </em> CHRIS relies on the color additive having a distribution that is macroscopically homogeneous within the matrix (e.g. CAs used for surface marking would be excluded); thus, any particles or aggregates must be small relative to the component and homogeneously distributed. This can be confirmed/justified through the use of particle coatings and/or dispersants in the concentrate to prevent aggregation and promote homogeneity, macroscopic observations of color uniformity, and/or microscopic observations to evaluate the potential for surface segregation phenomena, such as blooming.</p>
204
- <p><em>Dilute concentration - </em> The model relies on a concentration independent diffusion coefficient, which assumes any color additives are present only in dilute quantities. Confirming that the total amount of color additives present is &le; 2 m/v % is sufficient to conform with this assumption. It may be possible to justify that the CHRIS calculation for a dilute compound will remain protective if the total concentration is in excess of 2 m/v %, if the presence of additional compound could reasonably be expected to inhibit rather than promote diffusion, e.g. second phase particulates. </p>
205
- <p><em>Matrix stability - </em> The model parameters/transport properties are established using worst-case values reported in the literature. However, it is unclear if the reported values account for potential degradation (e.g. during sterilization) or other physicochemical changes (e.g. excessive plasticization) that may occur during manufacturing and negatively impact these values. Polymer stability can be confirmed/justified by evidence supporting that manufacturing (including sterilization) does not alter the matrix material of the final device. </p>
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
206
  </div>
207
  <div class="modal-footer">
208
  <button type="button" class="btn btn-default" data-dismiss="modal">Close</button>
 
53
  </head>
54
 
55
  <header>
56
+ <h2>CHemical RISk calculator (CHRIS) - Bulk chemicals</h2>
57
  </header>
58
 
59
  <p><strong>Disclaimer: This module only addresses risk associated with the bulk chemicals of known initial quantity.
 
61
  Further, a successful evaluation does not address local biocompatibility endpoints, and therefore additional testing
62
  may be needed despite a positive outcome. </strong></p>
63
 
64
+ For details on how to use CHRIS, please click the information icons next to each section header and read the
65
+ <a href="{{url_for('static', filename='exposure_COU.html')}}"> context of use (COU)</a>.
66
+
67
  <body>
68
 
69
  <form method="POST">
 
166
  <div class="modal-body">
167
  <p><em>Exposed surface area</em> - Enter the patient contacting surface area of the component being evaluated in square centimeters.
168
  This includes both direct and indirect patient contact.</p>
169
+ <p><em>Exposure type</em> - Select the appropriate exposure category: > 30 days = long-term, > 24 hours - 30 days = prolonged, &#8804; 24 hours = limited.
170
  For limited exposures (&#8804; 24 hours), please enter the maximum exposure time in hours.</p>
171
  </div>
172
  <div class="modal-footer">
 
201
  <h4 class="modal-title">Assumptions</h4>
202
  </div>
203
  <div class="modal-body">
204
+ <p>The exposure model relies on assumptions that are typically valid for bulk solutes in polymeric device components.
205
+ However, if any of the assumptions are violated the exposure calculation may not remain protective. Therefore,
206
+ if the output of CHRIS is used to support a submission to CDRH, users must confirm conformance to the underlying
207
+ assumptions or provide supporting justification. Examples of considerations when confirming conformance are provided below:</p>
208
+ <p><em>Biostability of the matrix - </em> While many of the matrices listed within CHRIS will not appreciably
209
+ swell or degrade in any physiological environment, this can not be generalized. For example, silicones may swell
210
+ in lipid-rich environments. Chemical compatibility of the polymer matrix with the use environment can be assessed based
211
+ on historical use and/or evaluation of swelling and/or degradation propensity in physiologically relevant media. </p>
212
+ <p><em>Particle/aggregate size and distribution - </em> Because CHRIS only addresses compounds with a distribution that is macroscopically
213
+ homogeneous within the matrix, the tool can only be used to assess bulk additives and impurities. Therefore, only compounds that are introduced
214
+ either intentionally or unintentionally during synthesis (e.g. residual monomers and oligomers, catalysts, initiators) or compounding (e.g. stabilizers,
215
+ antioxidants, plasticizers) are within scope. Surface residuals from processing, cleaning, and sterilization are excluded. Further,
216
+ any particles or aggregates must be small relative to the component and homogeneously distributed. This can be confirmed/justified microscopic
217
+ observations to evaluate the potential for surface segregation phenomena, such as blooming.</p>
218
+ <p><em>Dilute concentration - </em> The model relies on a concentration independent diffusion coefficient, which assumes the chemicals are present only in dilute
219
+ quantities. Confirming that the total amount of additives and impurities present is &le; 2 m/v % is sufficient to conform with this assumption.
220
+ It may be possible to justify that the CHRIS calculation for a dilute compound will remain protective if the total concentration is in excess of 2 m/v %,
221
+ if the presence of additional compound could reasonably be expected to inhibit rather than promote diffusion, e.g. second phase particulates. </p>
222
+ <p><em>Matrix stability - </em> The model parameters/transport properties are established using worst-case values reported in the literature.
223
+ However, it is unclear if the reported values account for potential degradation (e.g. during sterilization) or other physicochemical changes (e.g.
224
+ excessive plasticization) that may occur during manufacturing and negatively impact these values. Polymer stability can be confirmed/justified by
225
+ evidence supporting that manufacturing (including sterilization) does not alter the matrix material of the final device. </p>
226
  </div>
227
  <div class="modal-footer">
228
  <button type="button" class="btn btn-default" data-dismiss="modal">Close</button>
templates/exposure_report.html CHANGED
@@ -12,7 +12,7 @@ body {font-family: Arial, Helvetica, sans-serif;}
12
  </head>
13
 
14
  <header>
15
- <h2>Color Hazard and RISk calculator (CHRIS) Report </h2>
16
  </header>
17
 
18
  <body>
@@ -24,7 +24,7 @@ body {font-family: Arial, Helvetica, sans-serif;}
24
  <h3>Exposure </h3>
25
 
26
  <p>
27
- <u> Diffusion calculation for {{chemName}} leaching from {{polymers[pIndex]}} estimates a worst case single day exposure = {{release}} mg. </u>
28
  <p>
29
 
30
  <p>
 
12
  </head>
13
 
14
  <header>
15
+ <h2>CHemical RISk calculator (CHRIS) Report </h2>
16
  </header>
17
 
18
  <body>
 
24
  <h3>Exposure </h3>
25
 
26
  <p>
27
+ <u> Diffusion calculation for {{chemName}} leaching from {{polymers[pIndex]}} estimates the worst case single day exposure = {{release}} mg. </u>
28
  <p>
29
 
30
  <p>
templates/index.html CHANGED
@@ -56,10 +56,17 @@ body {font-family: Arial, Helvetica, sans-serif;}
56
  <h2>CHemical RISk calculator (CHRIS) - Color additives </h2>
57
  </header>
58
 
59
- <p><strong>Disclaimer: CHRIS only addresses risk associated with the presence of color additives and additives and impurities associated with the color additive. Therefore, a favorable outcome by CHRIS does not imply acceptable biological risk for the final finished form of a medical device. Further, a successful CHRIS evaluation does not address local biocompatibility endpoints, and therefore additional testing may be needed despite a positive outcome from CHRIS. Because there may be additional restrictions based on specific device guidance and code of federal regulation (CFR) listings, users should also review the relevant documents for their device type and color additive. </strong></p>
 
 
 
 
 
60
 
61
 
62
- <p> For details on how to use CHRIS, please read the <a href="{{url_for('static', filename='README.html')}}"> instructions.</a> and <a href="{{url_for('static', filename='COU.html')}}"> context of use (COU)</a>. Answers to frequently asked questions can be found <a href="{{url_for('static', filename='FAQ.html')}}"> here</a>.</p>
 
 
63
 
64
  <body>
65
 
@@ -198,7 +205,7 @@ Density (g/cm<sup>3</sup>): <input name="density" id="density" step="any" value=
198
  </div>
199
  <div class="modal-body">
200
  <p><em>Exposed surface area</em> - Enter the patient contacting surface area of the color additive containing component being evaluated in square centimeters. This includes both direct and indirect patient contact.</p>
201
- <p><em>Exposure type</em> - Select the appropriate exposure category: > 30 days = permanent, > 24 hours - 30 days = prolonged, &#8804; 24 hours = limited. For limited exposures (&#8804; 24 hours), please enter the maximum exposure time in hours.</p>
202
  </div>
203
  <div class="modal-footer">
204
  <button type="button" class="btn btn-default" data-dismiss="modal">Close</button>
 
56
  <h2>CHemical RISk calculator (CHRIS) - Color additives </h2>
57
  </header>
58
 
59
+ <p><strong>Disclaimer: This module only addresses risk associated with the presence of color additives and additives and impurities
60
+ associated with the color additive. Therefore, a favorable outcome does not imply acceptable biological risk for the final
61
+ finished form of a medical device. Further, a successful evaluation does not address local biocompatibility endpoints, and
62
+ therefore additional testing may be needed despite a positive outcome from CHRIS. Because there may be additional restrictions
63
+ based on specific device guidance and code of federal regulation (CFR) listings, users should also review the relevant documents
64
+ for their device type and color additive. </strong></p>
65
 
66
 
67
+ <p> For details on how to use CHRIS, please read the <a href="{{url_for('static', filename='README.html')}}"> instructions.</a> and
68
+ <a href="{{url_for('static', filename='COU.html')}}"> context of use (COU)</a>. Answers to frequently asked questions can be
69
+ found <a href="{{url_for('static', filename='FAQ.html')}}"> here</a>.</p>
70
 
71
  <body>
72
 
 
205
  </div>
206
  <div class="modal-body">
207
  <p><em>Exposed surface area</em> - Enter the patient contacting surface area of the color additive containing component being evaluated in square centimeters. This includes both direct and indirect patient contact.</p>
208
+ <p><em>Exposure type</em> - Select the appropriate exposure category: > 30 days = long-term, > 24 hours - 30 days = prolonged, &#8804; 24 hours = limited. For limited exposures (&#8804; 24 hours), please enter the maximum exposure time in hours.</p>
209
  </div>
210
  <div class="modal-footer">
211
  <button type="button" class="btn btn-default" data-dismiss="modal">Close</button>
templates/main.html CHANGED
@@ -11,13 +11,13 @@ body {font-family: Arial, Helvetica, sans-serif;}
11
  </head>
12
 
13
  <header>
14
- <h1>Chemical RISk calculator (CHRIS)</h1>
15
  </header>
16
 
17
  <body>
18
 
19
  <p>
20
- The Chemical RISk calculator (CHRIS) is a collection of modules to facilitate the use of physics based models to estimate exposure
21
  as part of toxicological risk assessment (TRA) of medical device polymers.
22
  </p>
23
 
@@ -25,8 +25,8 @@ as part of toxicological risk assessment (TRA) of medical device polymers.
25
 
26
  <p> Screening-level TRA for color additives - <a href="/color">here</a> </p>
27
 
28
- <p> Exposure estimation for bulk chemicals - <a href="/exposure">here</a> </p>
29
 
30
- <p> Estimation of total pool of a bulk chemical from extraction data - <a href="/extraction">here</a> </p>
31
 
32
  </body>
 
11
  </head>
12
 
13
  <header>
14
+ <h1>CHemical RISk calculator (CHRIS)</h1>
15
  </header>
16
 
17
  <body>
18
 
19
  <p>
20
+ The CHemical RISk calculator (CHRIS) is a collection of modules to facilitate the use of physics based models to estimate exposure
21
  as part of toxicological risk assessment (TRA) of medical device polymers.
22
  </p>
23
 
 
25
 
26
  <p> Screening-level TRA for color additives - <a href="/color">here</a> </p>
27
 
28
+ <p> Screening-level TRA for general bulk chemicals - <a href="/exposure">here</a> </p>
29
 
30
+ <p> Estimation of the total pool of a bulk chemical from extraction data (in development) </p>
31
 
32
  </body>
templates/report.html CHANGED
@@ -12,7 +12,7 @@ body {font-family: Arial, Helvetica, sans-serif;}
12
  </head>
13
 
14
  <header>
15
- <h2>Color Hazard and RISk calculator (CHRIS) Report </h2>
16
  </header>
17
 
18
  <body>
@@ -24,7 +24,7 @@ body {font-family: Arial, Helvetica, sans-serif;}
24
  <h3>Exposure </h3>
25
 
26
  <p>
27
- <u> Diffusion calculation for {{chemName}} leaching from {{polymers[pIndex]}} estimates a worst case single day exposure = {{release}} mg. </u>
28
  <p>
29
 
30
  <p>
 
12
  </head>
13
 
14
  <header>
15
+ <h2>CHemical RISk calculator (CHRIS) Report </h2>
16
  </header>
17
 
18
  <body>
 
24
  <h3>Exposure </h3>
25
 
26
  <p>
27
+ <u> Diffusion calculation for {{chemName}} leaching from {{polymers[pIndex]}} estimates the worst case single day exposure = {{release}} mg. </u>
28
  <p>
29
 