static/COU.md
CHANGED
|
@@ -1,7 +1,14 @@
|
|
| 1 |
|
| 2 |
# Context of Use (COU)
|
| 3 |
|
| 4 |
-
The Color Hazard and RISk calculator (CHRIS) is (proposed to be) qualified to conduct screening level risk assessments
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 |
|
| 6 |
Because CHRIS only addresses CAs, a favorable outcome by CHRIS does not imply acceptable biological risk for the final finished form of a medical device. CHRIS is also not intended to establish device classification or identify biocompatibility requirements. However, in addition to providing guidance to device manufacturers on acceptable levels of CA in a particular device, CHRIS can potentially be used to:
|
| 7 |
|
|
|
|
| 1 |
|
| 2 |
# Context of Use (COU)
|
| 3 |
|
| 4 |
+
The Color Hazard and RISk calculator (CHRIS) is (proposed to be) qualified to conduct screening level risk assessments
|
| 5 |
+
to aid in the biocompatibility evaluation of polymeric medical device components that contain color additives (CAs)[^1].
|
| 6 |
+
These assessments can assist device manufacturers by providing instantaneous feedback on whether the presence of CAs or
|
| 7 |
+
other additives and impurities associated with CAs in a device would require additional justification and/or testing to
|
| 8 |
+
demonstrate acceptable biological risk. The output of CHRIS is a conservative margin of safety (MOS = toxicological
|
| 9 |
+
safety limit ÷ exposure dose) value for a CA (and associated additives and impurities) contained within a polymeric
|
| 10 |
+
medical device component. Based on the MOS value, the calculator determines if further assessment of one or more
|
| 11 |
+
biocompatibility endpoints is necessary for the CA and/or associated impurities.
|
| 12 |
|
| 13 |
Because CHRIS only addresses CAs, a favorable outcome by CHRIS does not imply acceptable biological risk for the final finished form of a medical device. CHRIS is also not intended to establish device classification or identify biocompatibility requirements. However, in addition to providing guidance to device manufacturers on acceptable levels of CA in a particular device, CHRIS can potentially be used to:
|
| 14 |
|
templates/index.html
CHANGED
|
@@ -3,8 +3,8 @@
|
|
| 3 |
<head>
|
| 4 |
<meta charset="UTF-8">
|
| 5 |
<title>CHRIS</title>
|
| 6 |
-
<script src="https://ajax.googleapis.com/ajax/libs/jquery/3.5.1/jquery.min.js"></script>
|
| 7 |
-
<script src="https://maxcdn.bootstrapcdn.com/bootstrap/3.4.1/js/bootstrap.min.js"></script>
|
| 8 |
<style>
|
| 9 |
body {font-family: Arial, Helvetica, sans-serif;}
|
| 10 |
|
|
@@ -137,8 +137,6 @@ function caCheck() {
|
|
| 137 |
|
| 138 |
<!-- Polymer matrix input section -->
|
| 139 |
|
| 140 |
-
<polymer>
|
| 141 |
-
|
| 142 |
<h3> Polymer matrix <button type="button" class="Info_btn" data-toggle="modal" data-target="#PolymerModal">ⓘ</button> </h3>
|
| 143 |
Matrix: <select name="polymer">
|
| 144 |
<option value="{{polymers[0]}}" selected>{{polymers[0]}}</option>
|
|
@@ -171,11 +169,9 @@ Density (g/cm<sup>3</sup>): <input name="density" id="density" step="any" value=
|
|
| 171 |
|
| 172 |
</div>
|
| 173 |
</div>
|
| 174 |
-
</polymer>
|
| 175 |
|
| 176 |
<!-- Device characteristics input section -->
|
| 177 |
|
| 178 |
-
<device>
|
| 179 |
<h3> Device characteristics <button type=button class="Info_btn" data-toggle="modal" data-target="#DeviceModal">ⓘ</button> </h3>
|
| 180 |
Exposed surface area (cm<sup>2</sup>):
|
| 181 |
<input name="area" id="area" step="any" value="5.0" min="0.001" type="number"><br>
|
|
@@ -208,12 +204,8 @@ Density (g/cm<sup>3</sup>): <input name="density" id="density" step="any" value=
|
|
| 208 |
</div>
|
| 209 |
</div>
|
| 210 |
|
| 211 |
-
</device>
|
| 212 |
-
|
| 213 |
<!-- Assumptions input section -->
|
| 214 |
|
| 215 |
-
<assume>
|
| 216 |
-
|
| 217 |
<h3> Assumptions <button type=button class="Info_btn" data-toggle="modal" data-target="#AssumeModal">ⓘ</button> </h3>
|
| 218 |
Check all statements below that are applicable to your color additive containing component:<br><br>
|
| 219 |
<input type="checkbox" id="assume1" name="assume1" > The clinical use environment does not cause the polymer matrix to swell or degrade.<br>
|
|
@@ -246,9 +238,6 @@ Density (g/cm<sup>3</sup>): <input name="density" id="density" step="any" value=
|
|
| 246 |
</div>
|
| 247 |
</div>
|
| 248 |
|
| 249 |
-
</assume>
|
| 250 |
-
|
| 251 |
-
|
| 252 |
<h3> Exposure assessment </h3>
|
| 253 |
Click to screen your device: <button type="submit">Estimate exposure</button>
|
| 254 |
|
|
|
|
| 3 |
<head>
|
| 4 |
<meta charset="UTF-8">
|
| 5 |
<title>CHRIS</title>
|
| 6 |
+
<!---<script src="https://ajax.googleapis.com/ajax/libs/jquery/3.5.1/jquery.min.js"></script>
|
| 7 |
+
<script src="https://maxcdn.bootstrapcdn.com/bootstrap/3.4.1/js/bootstrap.min.js"></script>--->
|
| 8 |
<style>
|
| 9 |
body {font-family: Arial, Helvetica, sans-serif;}
|
| 10 |
|
|
|
|
| 137 |
|
| 138 |
<!-- Polymer matrix input section -->
|
| 139 |
|
|
|
|
|
|
|
| 140 |
<h3> Polymer matrix <button type="button" class="Info_btn" data-toggle="modal" data-target="#PolymerModal">ⓘ</button> </h3>
|
| 141 |
Matrix: <select name="polymer">
|
| 142 |
<option value="{{polymers[0]}}" selected>{{polymers[0]}}</option>
|
|
|
|
| 169 |
|
| 170 |
</div>
|
| 171 |
</div>
|
|
|
|
| 172 |
|
| 173 |
<!-- Device characteristics input section -->
|
| 174 |
|
|
|
|
| 175 |
<h3> Device characteristics <button type=button class="Info_btn" data-toggle="modal" data-target="#DeviceModal">ⓘ</button> </h3>
|
| 176 |
Exposed surface area (cm<sup>2</sup>):
|
| 177 |
<input name="area" id="area" step="any" value="5.0" min="0.001" type="number"><br>
|
|
|
|
| 204 |
</div>
|
| 205 |
</div>
|
| 206 |
|
|
|
|
|
|
|
| 207 |
<!-- Assumptions input section -->
|
| 208 |
|
|
|
|
|
|
|
| 209 |
<h3> Assumptions <button type=button class="Info_btn" data-toggle="modal" data-target="#AssumeModal">ⓘ</button> </h3>
|
| 210 |
Check all statements below that are applicable to your color additive containing component:<br><br>
|
| 211 |
<input type="checkbox" id="assume1" name="assume1" > The clinical use environment does not cause the polymer matrix to swell or degrade.<br>
|
|
|
|
| 238 |
</div>
|
| 239 |
</div>
|
| 240 |
|
|
|
|
|
|
|
|
|
|
| 241 |
<h3> Exposure assessment </h3>
|
| 242 |
Click to screen your device: <button type="submit">Estimate exposure</button>
|
| 243 |
|
templates/report.html
CHANGED
|
@@ -24,7 +24,8 @@ body {font-family: Arial, Helvetica, sans-serif;}
|
|
| 24 |
<h3>Exposure </h3>
|
| 25 |
|
| 26 |
<p>
|
| 27 |
-
<u> Diffusion calculation for {{chemName}} leaching from {{polymers[pIndex]}} estimates a worst case single day
|
|
|
|
| 28 |
<p>
|
| 29 |
|
| 30 |
<p>
|
|
@@ -38,7 +39,10 @@ M(\tau)= \left\{
|
|
| 38 |
\end{array} \right.
|
| 39 |
\]
|
| 40 |
|
| 41 |
-
where \( \tau= D t A^2 / V^2 \) and \( A \) and \( V \) are the surface area and volume of the polymer matrix,
|
|
|
|
|
|
|
|
|
|
| 42 |
</p>
|
| 43 |
|
| 44 |
<p>
|
|
@@ -54,13 +58,17 @@ where \( \tau= D t A^2 / V^2 \) and \( A \) and \( V \) are the surface area and
|
|
| 54 |
{% if assume[0] and assume[1] and assume[2] and assume[3] and assume[4] %}
|
| 55 |
|
| 56 |
<p>
|
| 57 |
-
<font color="green"> You have confirmed your system complies with the model assumptions and no further data are needed
|
|
|
|
| 58 |
</p>
|
| 59 |
|
| 60 |
{% else %}
|
| 61 |
|
| 62 |
<p>
|
| 63 |
-
<font color="red"> You have not confirmed compliance with one or more of the underlying assumptions upon which the
|
|
|
|
|
|
|
|
|
|
| 64 |
</p>
|
| 65 |
|
| 66 |
{% if not assume[0] %}
|
|
@@ -68,7 +76,8 @@ where \( \tau= D t A^2 / V^2 \) and \( A \) and \( V \) are the surface area and
|
|
| 68 |
{% endif %}
|
| 69 |
|
| 70 |
{% if not assume[1] %}
|
| 71 |
-
<font color="red"> • Any color additive particles/aggregates are much smaller than the smallest component dimension
|
|
|
|
| 72 |
{% endif %}
|
| 73 |
|
| 74 |
{% if not assume[2] %}
|
|
@@ -90,13 +99,15 @@ where \( \tau= D t A^2 / V^2 \) and \( A \) and \( V \) are the surface area and
|
|
| 90 |
{% if caIndex > 10 %}
|
| 91 |
|
| 92 |
<p>
|
| 93 |
-
The threshold for toxicological concern (TTC) for {{exposure}} contact is {{TTC}} mg. Based on the exposure estimation
|
|
|
|
| 94 |
</p>
|
| 95 |
|
| 96 |
{% if MOS >= 1 %}
|
| 97 |
|
| 98 |
<p>
|
| 99 |
-
<font color="green"> The MOS based on the mutagenic TTC is greater than one; therefore, no further analysis is needed
|
|
|
|
| 100 |
</p>
|
| 101 |
|
| 102 |
<p>
|
|
@@ -106,29 +117,37 @@ The threshold for toxicological concern (TTC) for {{exposure}} contact is {{TTC}
|
|
| 106 |
{% else %}
|
| 107 |
|
| 108 |
<p>
|
| 109 |
-
<font color="red"> The MOS based on the mutagenic TTC is less than one; therefore, further analysis is needed to
|
|
|
|
|
|
|
| 110 |
</p>
|
| 111 |
|
| 112 |
{% endif %}
|
| 113 |
|
| 114 |
{% else %}
|
| 115 |
|
| 116 |
-
The tolerable intake value for your color additive is {{TI}} mg/kg/day. Assuming a 50 kg patient, the tolerable
|
|
|
|
|
|
|
| 117 |
|
| 118 |
{% if MOS >= 1 %}
|
| 119 |
|
| 120 |
<p>
|
| 121 |
-
<font color="green"> The MOS based on the color additive specific TI is greater than one; therefore, no further analysis
|
|
|
|
| 122 |
</p>
|
| 123 |
|
| 124 |
<p>
|
| 125 |
-
<font color="red"> *Note*: This calculation assumes an adult patient population with a worst-case body weight of 50 kg.
|
|
|
|
|
|
|
| 126 |
</p>
|
| 127 |
|
| 128 |
{% else %}
|
| 129 |
|
| 130 |
<p>
|
| 131 |
-
<font color="red"> The MOS based on the color additive specific TI is less than one; therefore, further analysis is
|
|
|
|
| 132 |
</p>
|
| 133 |
|
| 134 |
{% endif %}
|
|
@@ -138,7 +157,10 @@ The tolerable intake value for your color additive is {{TI}} mg/kg/day. Assumin
|
|
| 138 |
{% if isCA == true %}
|
| 139 |
|
| 140 |
<p>
|
| 141 |
-
<font color="red"> *Note*: This assessment assumes that the color additive complies with all relevant medical device
|
|
|
|
|
|
|
|
|
|
| 142 |
</p>
|
| 143 |
|
| 144 |
{% endif %}
|
|
@@ -149,19 +171,27 @@ The tolerable intake value for your color additive is {{TI}} mg/kg/day. Assumin
|
|
| 149 |
|
| 150 |
{% if iMOS >= 1 %}
|
| 151 |
|
| 152 |
-
<font color="green"> The total color additive impurity level is {{impurity}} mg. When compared to TTC this results in
|
|
|
|
|
|
|
| 153 |
|
| 154 |
<p>
|
| 155 |
<font color="red"> *Note*: This assessment assumes that any impurities present are not in the cohort of concern. </font>
|
| 156 |
</p>
|
| 157 |
|
| 158 |
<p>
|
| 159 |
-
<font color="red"> *Note*: Users should review and confirm compliance of impurity levels with any relevant Code of
|
|
|
|
|
|
|
|
|
|
| 160 |
</p>
|
| 161 |
|
| 162 |
{% else %}
|
| 163 |
|
| 164 |
-
<font color="red"> The total color additive impurity level is {{impurity}} mg. When compared to TTC this results in
|
|
|
|
|
|
|
|
|
|
| 165 |
|
| 166 |
|
| 167 |
{% endif %}
|
|
|
|
| 24 |
<h3>Exposure </h3>
|
| 25 |
|
| 26 |
<p>
|
| 27 |
+
<u> Diffusion calculation for {{chemName}} leaching from {{polymers[pIndex]}} estimates a worst case single day
|
| 28 |
+
exposure = {{release}} mg. </u>
|
| 29 |
<p>
|
| 30 |
|
| 31 |
<p>
|
|
|
|
| 39 |
\end{array} \right.
|
| 40 |
\]
|
| 41 |
|
| 42 |
+
where \( \tau= D t A^2 / V^2 \) and \( A \) and \( V \) are the surface area and volume of the polymer matrix,
|
| 43 |
+
respectively, \( M_0 \) is total mass initially contained in the polymer, \( D \) is a conservative estimate of
|
| 44 |
+
the diffusion coefficient of the leachable within the polymer matrix, and \( t \) is time. Based on the input
|
| 45 |
+
provided, the calculation was based on the following values:
|
| 46 |
</p>
|
| 47 |
|
| 48 |
<p>
|
|
|
|
| 58 |
{% if assume[0] and assume[1] and assume[2] and assume[3] and assume[4] %}
|
| 59 |
|
| 60 |
<p>
|
| 61 |
+
<font color="green"> You have confirmed your system complies with the model assumptions and no further data are needed
|
| 62 |
+
to support using the exposure estimation provided by CHRIS in a submission to CDRH. </font>
|
| 63 |
</p>
|
| 64 |
|
| 65 |
{% else %}
|
| 66 |
|
| 67 |
<p>
|
| 68 |
+
<font color="red"> You have not confirmed compliance with one or more of the underlying assumptions upon which the
|
| 69 |
+
exposure calculation is based. Therefore, it may be necessary to provide a justification and supporting data for
|
| 70 |
+
why the results obtained for a system that may not comply with unchecked assumptions below are still valid if the
|
| 71 |
+
assessment is used to support a submission to CDRH: </font> <br>
|
| 72 |
</p>
|
| 73 |
|
| 74 |
{% if not assume[0] %}
|
|
|
|
| 76 |
{% endif %}
|
| 77 |
|
| 78 |
{% if not assume[1] %}
|
| 79 |
+
<font color="red"> • Any color additive particles/aggregates are much smaller than the smallest component dimension
|
| 80 |
+
(≤ 50x). <br> </font>
|
| 81 |
{% endif %}
|
| 82 |
|
| 83 |
{% if not assume[2] %}
|
|
|
|
| 99 |
{% if caIndex > 10 %}
|
| 100 |
|
| 101 |
<p>
|
| 102 |
+
The threshold for toxicological concern (TTC) for {{exposure}} contact is {{TTC}} mg. Based on the exposure estimation
|
| 103 |
+
this results in a margin of safety (MOS) of {{MOS}}.
|
| 104 |
</p>
|
| 105 |
|
| 106 |
{% if MOS >= 1 %}
|
| 107 |
|
| 108 |
<p>
|
| 109 |
+
<font color="green"> The MOS based on the mutagenic TTC is greater than one; therefore, no further analysis is needed
|
| 110 |
+
for systemic biocompatibility endpoints. </font>
|
| 111 |
</p>
|
| 112 |
|
| 113 |
<p>
|
|
|
|
| 117 |
{% else %}
|
| 118 |
|
| 119 |
<p>
|
| 120 |
+
<font color="red"> The MOS based on the mutagenic TTC is less than one; therefore, further analysis is needed to
|
| 121 |
+
address systemic biocompatibility endpoints. For example, a compound specific tolerable intake value could be
|
| 122 |
+
independently derived and compared to the exposure estimate provided above. </font>
|
| 123 |
</p>
|
| 124 |
|
| 125 |
{% endif %}
|
| 126 |
|
| 127 |
{% else %}
|
| 128 |
|
| 129 |
+
The tolerable intake value for your color additive is {{TI}} mg/kg/day. Assuming a 50 kg patient, the tolerable
|
| 130 |
+
exposure value would be {{50*TI}} mg/day. Based on the exposure estimation this results in a margin of safety (MOS)
|
| 131 |
+
of {{MOS}}.
|
| 132 |
|
| 133 |
{% if MOS >= 1 %}
|
| 134 |
|
| 135 |
<p>
|
| 136 |
+
<font color="green"> The MOS based on the color additive specific TI is greater than one; therefore, no further analysis
|
| 137 |
+
is needed for systemic biocompatibility endpoints. </font>
|
| 138 |
</p>
|
| 139 |
|
| 140 |
<p>
|
| 141 |
+
<font color="red"> *Note*: This calculation assumes an adult patient population with a worst-case body weight of 50 kg.
|
| 142 |
+
If the intended patient population of your device is different, please adjust the tolerable exposure calculation
|
| 143 |
+
accordingly. </font>
|
| 144 |
</p>
|
| 145 |
|
| 146 |
{% else %}
|
| 147 |
|
| 148 |
<p>
|
| 149 |
+
<font color="red"> The MOS based on the color additive specific TI is less than one; therefore, further analysis is
|
| 150 |
+
needed to address systemic biocompatibility endpoints. </font>
|
| 151 |
</p>
|
| 152 |
|
| 153 |
{% endif %}
|
|
|
|
| 157 |
{% if isCA == true %}
|
| 158 |
|
| 159 |
<p>
|
| 160 |
+
<font color="red"> *Note*: This assessment assumes that the color additive complies with all relevant medical device
|
| 161 |
+
specific guidance documents and all relevant Code of Federal Regulations (CFR) color additive listings, if they
|
| 162 |
+
exist for the color additive. Examples of CFR listings are provided in the
|
| 163 |
+
<a href="static/FAQ.html#how-does-chris-deal-with-color-additive-impurities" >FAQ</a>.</font>
|
| 164 |
</p>
|
| 165 |
|
| 166 |
{% endif %}
|
|
|
|
| 171 |
|
| 172 |
{% if iMOS >= 1 %}
|
| 173 |
|
| 174 |
+
<font color="green"> The total color additive impurity level is {{impurity}} mg. When compared to TTC this results in
|
| 175 |
+
an MOS = {{iMOS}}. Therefore, no further analysis is needed for the impact of impurities on systemic
|
| 176 |
+
biocompatibility endpoints. </font>
|
| 177 |
|
| 178 |
<p>
|
| 179 |
<font color="red"> *Note*: This assessment assumes that any impurities present are not in the cohort of concern. </font>
|
| 180 |
</p>
|
| 181 |
|
| 182 |
<p>
|
| 183 |
+
<font color="red"> *Note*: Users should review and confirm compliance of impurity levels with any relevant Code of
|
| 184 |
+
Federal Regulations (CFR) listings as part of the submission package, i.e. in addition to any output of CHRIS.
|
| 185 |
+
A list of relevant CFR listings is provided
|
| 186 |
+
<a href="static/FAQ.html#how-does-chris-deal-with-color-additive-impurities" >here</a>.</font>
|
| 187 |
</p>
|
| 188 |
|
| 189 |
{% else %}
|
| 190 |
|
| 191 |
+
<font color="red"> The total color additive impurity level is {{impurity}} mg. When compared to TTC this results in
|
| 192 |
+
an MOS = {{iMOS}}. Therefore, further analysis is needed to address the impact of impurities on systemic
|
| 193 |
+
biocompatibility endpoints. Guidance on alternative methods to address impurities is provided
|
| 194 |
+
<a href="static/FAQ.html#how-does-chris-deal-with-color-additive-impurities" >here</a>. </font>
|
| 195 |
|
| 196 |
|
| 197 |
{% endif %}
|