Robert Elder commited on
Commit
ecaf168
·
1 Parent(s): 2db31a7

more Echo updates

Browse files
color3_module/colors.py CHANGED
@@ -192,9 +192,9 @@ def app_post():
192
  #print(release_list, file=sys.stderr)
193
  frac_list = [str(SigFigs(r/amount*100,2))+'%' for r in release_list]
194
  release_list = [SigFigs(r,2) for r in release_list]
195
- df_rel = pd.DataFrame(np.transpose([tlist,release_list,frac_list]),columns=['Exposure time (days)',f'Cumulative release ({units})','Cumulative release (%)'])
196
- df_rel['Exposure time (days)'] = df_rel['Exposure time (days)'].astype(float)
197
- release_table = df_rel.sort_values(by='Exposure time (days)').to_html(index=False)
198
 
199
  MOS = SigFigs(MOS, 2)
200
  diff = SigFigs(diff, 2)
 
192
  #print(release_list, file=sys.stderr)
193
  frac_list = [str(SigFigs(r/amount*100,2))+'%' for r in release_list]
194
  release_list = [SigFigs(r,2) for r in release_list]
195
+ df_rel = pd.DataFrame(np.transpose([tlist,release_list,frac_list]),columns=['Exposure duration (days)',f'Cumulative exposure ({units})','Cumulative exposure (%)'])
196
+ df_rel['Exposure duration (days)'] = df_rel['Exposure duration (days)'].astype(float)
197
+ release_table = df_rel.sort_values(by='Exposure duration (days)').to_html(index=False)
198
 
199
  MOS = SigFigs(MOS, 2)
200
  diff = SigFigs(diff, 2)
color3_module/templates/color3_report.html CHANGED
@@ -114,7 +114,7 @@ where \( \tau= D t A^2 / V^2 \) and \( A \) and \( V \) are the surface area and
114
  <p>
115
 
116
  <p>
117
- It can be helpful to examine the cumulative amount released over various exposure times. For example, the 30-day cumulative exposure may be compared to the TSL<sub>&le;30 d</sub> as recommended in ISO 10993-17:2023. Note that this calculation assumes a single device is used for the entire duration. If multiple devices are used concurrently or sequentially (e.g., daily replacement), this should be accounted for during toxicological risk assessment.
118
  </p>
119
 
120
  <div>
 
114
  <p>
115
 
116
  <p>
117
+ It can be helpful to examine the cumulative amount released over various exposure durations. For example, the 30-day cumulative exposure may be compared to the TSL<sub>&le;30 d</sub> as recommended in ISO 10993-17:2023. Note that this calculation assumes a single device is used for the entire duration. If multiple devices are used concurrently or sequentially (e.g., daily replacement), this should be accounted for during toxicological risk assessment.
118
  </p>
119
 
120
  <div>
exposure3_module/exposure.py CHANGED
@@ -166,9 +166,9 @@ def exp_post():
166
  #print(release_list, file=sys.stderr)
167
  frac_list = [str(SigFigs(r/amount*100,2))+'%' for r in release_list]
168
  release_list = [SigFigs(r,2) for r in release_list]
169
- df_rel = pd.DataFrame(np.transpose([tlist,release_list,frac_list]),columns=['Exposure time (days)',f'Cumulative release ({units})','Cumulative release (%)'])
170
- df_rel['Exposure time (days)'] = df_rel['Exposure time (days)'].astype(float)
171
- release_table = df_rel.sort_values(by='Exposure time (days)').to_html(index=False)
172
 
173
  release = SigFigs(release, 2)
174
  MOS = SigFigs(MOS, 2)
 
166
  #print(release_list, file=sys.stderr)
167
  frac_list = [str(SigFigs(r/amount*100,2))+'%' for r in release_list]
168
  release_list = [SigFigs(r,2) for r in release_list]
169
+ df_rel = pd.DataFrame(np.transpose([tlist,release_list,frac_list]),columns=['Exposure duration (days)',f'Cumulative exposure ({units})','Cumulative exposure (%)'])
170
+ df_rel['Exposure duration (days)'] = df_rel['Exposure duration (days)'].astype(float)
171
+ release_table = df_rel.sort_values(by='Exposure duration (days)').to_html(index=False)
172
 
173
  release = SigFigs(release, 2)
174
  MOS = SigFigs(MOS, 2)
exposure3_module/templates/exposure3_report.html CHANGED
@@ -110,7 +110,7 @@ where \( \tau= D t A^2 / V^2 \) and \( A \) and \( V \) are the surface area and
110
  </p>
111
 
112
  <p>
113
- It can be helpful to examine the cumulative amount released over various exposure times. For example, the 30-day cumulative exposure may be compared to the TSL<sub>&le;30 d</sub> as recommended in ISO 10993-17:2023. Note that this calculation assumes a single device is used for the entire duration. If multiple devices are used concurrently or sequentially (e.g., daily replacement), this should be accounted for during toxicological risk assessment.
114
  </p>
115
 
116
  <div>
 
110
  </p>
111
 
112
  <p>
113
+ It can be helpful to examine the cumulative amount released over various exposure durations. For example, the 30-day cumulative exposure may be compared to the TSL<sub>&le;30 d</sub> as recommended in ISO 10993-17:2023. Note that this calculation assumes a single device is used for the entire duration. If multiple devices are used concurrently or sequentially (e.g., daily replacement), this should be accounted for during toxicological risk assessment.
114
  </p>
115
 
116
  <div>