MajorProject / app.py
dwaynefernandes05's picture
initial commit
95b7e07
Raw History Blame Contribute Delete
20 kB
"""
RFP Cable Spec Matching — Gradio Prototype
Demonstrates Hybrid Retrieval across EXP1-EXP7 stress tests.
"""
import gradio as gr
import pandas as pd
import numpy as np
import json
import time
import re
from engine import (
HybridRetrievalEngine,
parse_spec_text,
extract_noise,
apply_numeric_perturbation,
apply_unit_variation,
apply_noise_injection,
apply_missing_params,
apply_partial_spec,
apply_positional_shift,
EXPERIMENT_DESCRIPTIONS,
build_product_catalog,
)
# ── Global engine (loaded once) ────────────────────────────────
print("Initialising retrieval engine...")
ENGINE = HybridRetrievalEngine(model_name='all-mpnet-base-v2')
print("Engine ready.")
# ── Sample RFP specs for demo button ───────────────────────────
SAMPLE_SPECS = [
{
"spec_text": "FRLS 11kV 3C 240sqmm Cu XLPE armoured cable as per IS 7098-2",
"voltage_rating": "11kV",
"core_count": "3",
"size_sqmm": "240.0",
"conductor": "Cu",
"insulation": "XLPE",
"armouring": "armoured",
"fire_rating": "FRLS",
"standards": "IS 7098-2",
"mandatory_specs": "voltage_rating;core_count;size_sqmm",
"label": "11kV 3C 240sqmm Cu XLPE FRLS Armoured",
},
{
"spec_text": "FR 1.1kV 4C 6sqmm Cu PVC unarmoured cable as per IS 694",
"voltage_rating": "1.1kV",
"core_count": "4",
"size_sqmm": "6.0",
"conductor": "Cu",
"insulation": "PVC",
"armouring": "unarmoured",
"fire_rating": "FR",
"standards": "IS 694",
"mandatory_specs": "voltage_rating",
"label": "1.1kV 4C 6sqmm Cu PVC FR Unarmoured",
},
{
"spec_text": "33kV 1C 300sqmm Al XLPE armoured cable as per IEC 60502-2",
"voltage_rating": "33kV",
"core_count": "1",
"size_sqmm": "300.0",
"conductor": "Al",
"insulation": "XLPE",
"armouring": "armoured",
"fire_rating": "",
"standards": "IEC 60502-2",
"mandatory_specs": "voltage_rating;size_sqmm",
"label": "33kV 1C 300sqmm Al XLPE Armoured",
},
]
EXPERIMENT_MODES = [
("🟢 Clean Baseline", "clean"),
("🔴 EXP1 — Numeric Perturbation", "numeric_perturbation"),
("🟡 EXP2 — Unit Variation", "unit_variation"),
("🟠 EXP3 — Missing Parameters", "missing_params"),
("🔵 EXP4 — In-Domain Noise", "noise_indomain"),
("🟣 EXP4 — Out-of-Domain Noise", "noise_outdomain"),
("⚫ EXP6 — Partial Spec", "partial_spec"),
("🔶 EXP7 — Positional Bias", "positional_end"),
]
EXP_CHOICES = [label for label, _ in EXPERIMENT_MODES]
EXP_KEY_MAP = {label: key for label, key in EXPERIMENT_MODES}
def build_rfp_dict(spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards, mandatory):
"""Assemble RFP dict from UI fields."""
# Parse from text if structured fields are empty
if not voltage and not cores and not size:
parsed = parse_spec_text(spec_text)
voltage = parsed['voltage_rating'] or voltage
cores = str(parsed['core_count']) or cores
size = str(parsed['size_sqmm']) or size
conductor = parsed['conductor_material'] or conductor
insulation = parsed['insulation_type'] or insulation
armouring = parsed['armouring_type'] or armouring
fire_rating= parsed['fire_rating'] or fire_rating
standards = parsed['standards_required'] or standards
return {
'spec_text_raw': spec_text,
'voltage_rating': voltage.strip(),
'core_count': cores.strip(),
'size_sqmm': size.strip(),
'conductor_material': conductor.strip(),
'insulation_type': insulation.strip(),
'armouring_type': armouring.strip(),
'fire_rating': fire_rating.strip(),
'sheath_material': '',
'standards_required': standards.strip(),
'mandatory_specs': mandatory.strip(),
}
def run_retrieval(spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards,
mandatory, experiment_mode, top_k):
"""Main inference function called by Gradio."""
if not spec_text.strip():
return "⚠️ Please enter a spec text.", "", "", pd.DataFrame()
rfp = build_rfp_dict(spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards, mandatory)
exp_key = EXP_KEY_MAP.get(experiment_mode, 'clean')
# Apply experiment transformation
if exp_key == 'numeric_perturbation':
rfp_exp = apply_numeric_perturbation(rfp)
elif exp_key == 'unit_variation':
rfp_exp = apply_unit_variation(rfp)
elif exp_key == 'missing_params':
rfp_exp = apply_missing_params(rfp, n_drop=2)
elif exp_key == 'noise_indomain':
rfp_exp = apply_noise_injection(rfp, 'in_domain')
elif exp_key == 'noise_outdomain':
rfp_exp = apply_noise_injection(rfp, 'out_of_domain')
elif exp_key == 'partial_spec':
rfp_exp = apply_partial_spec(rfp, level=2)
elif exp_key == 'positional_end':
rfp_exp = apply_positional_shift(rfp, position='end')
else:
rfp_exp = rfp
top_k = int(top_k)
results = ENGINE.retrieve(rfp_exp, top_k=top_k)
# Experiment info panel
exp_info = EXPERIMENT_DESCRIPTIONS[exp_key]
info_md = f"""### {exp_info['title']}
**What this tests:** {exp_info['description']}
**What changed in the spec:** `{exp_info['what_changes']}`
**Hybrid advantage:** _{exp_info['hybrid_advantage']}_
---
**Effective spec text sent to model:**
```
{rfp_exp['spec_text_raw'][:300]}{'...' if len(rfp_exp['spec_text_raw']) > 300 else ''}
```
"""
# Score breakdown (top result)
if results:
top = results[0]
latency = top['latency_ms']
score_md = f"""### Top Match: `{top['sku_id']}` — {top['product_name']}
| Score Component | Value | Weight |
|---|---|---|
| 🏗️ Structured | **{top['structured_score']:.3f}** | 50% |
| 🧠 Semantic (MiniLM) | **{top['semantic_score']:.3f}** | 30% |
| 📋 Standards | **{top['standards_score']:.3f}** | 20% |
| **🎯 Hybrid Total** | **{top['hybrid_score']:.3f}** | 100% |
⚡ **Latency:** {latency} ms
"""
else:
score_md = "No results found."
# Results table
rows = []
for r in results:
rows.append({
'Rank': r['rank'],
'SKU ID': r['sku_id'],
'Product': r['product_name'],
'Voltage': r['voltage_rating'],
'Cores': r['core_count'],
'Size (sqmm)': r['size_sqmm'],
'Conductor': r['conductor_material'],
'Insulation': r['insulation_type'],
'Armouring': r['armouring_type'],
'Fire Rating': r['fire_rating'],
'Standards': r['standards_complied'],
'🎯 Hybrid': f"{r['hybrid_score']:.3f}",
'🏗️ Struct': f"{r['structured_score']:.3f}",
'🧠 Semantic': f"{r['semantic_score']:.3f}",
'📋 Std': f"{r['standards_score']:.3f}",
})
df_results = pd.DataFrame(rows)
return info_md, score_md, df_results
def fill_sample(sample_idx):
"""Fill all form fields from a sample spec."""
s = SAMPLE_SPECS[int(sample_idx)]
return (
s["spec_text"],
s["voltage_rating"],
s["core_count"],
s["size_sqmm"],
s["conductor"],
s["insulation"],
s["armouring"],
s["fire_rating"],
s["standards"],
s["mandatory_specs"],
)
def auto_parse(spec_text):
"""Auto-fill structured fields from free text."""
parsed = parse_spec_text(spec_text)
return (
parsed['voltage_rating'],
str(parsed['core_count']) if parsed['core_count'] else '',
str(parsed['size_sqmm']) if parsed['size_sqmm'] else '',
parsed['conductor_material'],
parsed['insulation_type'],
parsed['armouring_type'],
parsed['fire_rating'],
parsed['standards_required'],
)
# ── Compare all experiments for one spec ──────────────────────
def compare_all_experiments(spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards, mandatory):
"""Run all 8 experiment modes and return a comparison table."""
if not spec_text.strip():
return pd.DataFrame(), "⚠️ Enter a spec first."
rfp_base = build_rfp_dict(spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards, mandatory)
experiments = {
'Clean Baseline': rfp_base,
'EXP1 Numeric Perturb': apply_numeric_perturbation(rfp_base),
'EXP2 Unit Variation': apply_unit_variation(rfp_base),
'EXP3 Missing Params': apply_missing_params(rfp_base),
'EXP4 In-Domain Noise': apply_noise_injection(rfp_base, 'in_domain'),
'EXP4 Out-Domain Noise': apply_noise_injection(rfp_base, 'out_of_domain'),
'EXP6 Partial Spec': apply_partial_spec(rfp_base),
'EXP7 Positional Bias': apply_positional_shift(rfp_base, 'end'),
}
rows = []
for exp_name, rfp_exp in experiments.items():
results = ENGINE.retrieve(rfp_exp, top_k=1)
if results:
r = results[0]
rows.append({
'Experiment': exp_name,
'Top-1 SKU': r['sku_id'],
'Top-1 Product': r['product_name'][:50],
'🎯 Hybrid': f"{r['hybrid_score']:.3f}",
'🏗️ Struct': f"{r['structured_score']:.3f}",
'🧠 Semantic': f"{r['semantic_score']:.3f}",
'📋 Std': f"{r['standards_score']:.3f}",
'⚡ ms': r['latency_ms'],
})
df = pd.DataFrame(rows)
summary = f"""### Comparison Summary
**Key Insight:** The 🏗️ Struct score stays stable across EXP1–EXP7 because it reads
structured columns (voltage_rating, core_count, size_sqmm etc.) — NOT the raw spec text.
The 🧠 Semantic score fluctuates when text is perturbed/noisy/partial — this is the SBERT
failure mode that the Hybrid model compensates for via the 50% structural weight.
"""
return df, summary
# ──────────────────────────────────────────────────────────────
# GRADIO UI
# ──────────────────────────────────────────────────────────────
CSS = """
.gradio-container { font-family: 'Inter', sans-serif; }
.tab-nav button { font-weight: 600; }
#title-block { text-align: center; padding: 10px 0 5px 0; }
.score-box { border-radius: 8px; }
"""
with gr.Blocks(css=CSS, title="RFP Cable Spec Matcher", theme=gr.themes.Soft()) as demo:
gr.HTML("""
<div id="title-block">
<h1>⚡ RFP Cable Specification Matcher</h1>
<p style="color:#555; font-size:0.95em;">
Hybrid Retrieval System &nbsp;|&nbsp; Structured (50%) + Semantic (30%) + Standards (20%)
&nbsp;|&nbsp; Experiments EXP1–EXP7
</p>
</div>
""")
with gr.Tabs():
# ── TAB 1: Single Query ──────────────────────────────
with gr.Tab("🔍 Single Query"):
with gr.Row():
with gr.Column(scale=2):
gr.Markdown("### 📋 RFP Specification Input")
spec_text = gr.Textbox(
label="Free-text Spec (spec_text_raw)",
placeholder="e.g. FRLS 11kV 3C 240sqmm Cu XLPE armoured cable as per IS 7098-2",
lines=3,
)
with gr.Row():
auto_parse_btn = gr.Button("🔄 Auto-Parse Fields", variant="secondary", size="sm")
gr.Markdown("")
gr.Markdown("#### Structured Fields *(used by Hybrid for stress-test immunity)*")
with gr.Row():
voltage = gr.Textbox(label="Voltage Rating", placeholder="e.g. 11kV")
cores = gr.Textbox(label="Core Count", placeholder="e.g. 3")
size = gr.Textbox(label="Size (sqmm)", placeholder="e.g. 240.0")
with gr.Row():
conductor = gr.Dropdown(["Cu", "Al", ""], label="Conductor", value="Cu")
insulation = gr.Dropdown(["XLPE", "PVC", "EPR", ""], label="Insulation", value="XLPE")
armouring = gr.Dropdown(["armoured", "unarmoured", ""], label="Armouring", value="armoured")
with gr.Row():
fire_rating = gr.Dropdown(["FRLS", "FR", "LSZH", ""], label="Fire Rating", value="FRLS")
standards = gr.Textbox(label="Standards Required", placeholder="e.g. IS 7098-2")
mandatory = gr.Textbox(
label="Mandatory Fields (semicolon-separated)",
placeholder="e.g. voltage_rating;core_count;size_sqmm",
value="voltage_rating;core_count"
)
gr.Markdown("#### Experiment Mode")
experiment_mode = gr.Radio(
choices=EXP_CHOICES,
value=EXP_CHOICES[0],
label="Select stress test to apply",
)
with gr.Row():
top_k_slider = gr.Slider(1, 10, value=5, step=1, label="Top-K results")
run_btn = gr.Button("🚀 Run Retrieval", variant="primary", size="lg")
gr.Markdown("---\n#### 📦 Load Sample Spec")
with gr.Row():
for i, s in enumerate(SAMPLE_SPECS):
gr.Button(f"Sample {i+1}: {s['label']}", size="sm").click(
fn=lambda idx=i: fill_sample(idx),
inputs=[],
outputs=[spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards, mandatory]
)
with gr.Column(scale=3):
gr.Markdown("### 📊 Results")
exp_info_md = gr.Markdown("*Run a query to see experiment info.*")
score_info_md = gr.Markdown("")
results_table = gr.DataFrame(label="Ranked Matches", wrap=True)
run_btn.click(
fn=run_retrieval,
inputs=[spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards,
mandatory, experiment_mode, top_k_slider],
outputs=[exp_info_md, score_info_md, results_table]
)
auto_parse_btn.click(
fn=auto_parse,
inputs=[spec_text],
outputs=[voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards]
)
# ── TAB 2: Compare All Experiments ──────────────────
with gr.Tab("📊 Compare All Experiments"):
gr.Markdown("""
### Run One Spec Across All 8 Experiment Modes
This shows exactly how Hybrid retrieval stays robust while SBERT-only would degrade.
Fill in a spec above (or load a sample) then click **Run Comparison**.
""")
compare_btn = gr.Button("▶️ Run All 8 Experiments", variant="primary")
compare_summary = gr.Markdown("")
compare_table = gr.DataFrame(label="Experiment Comparison", wrap=True)
compare_btn.click(
fn=compare_all_experiments,
inputs=[spec_text, voltage, cores, size, conductor,
insulation, armouring, fire_rating, standards, mandatory],
outputs=[compare_table, compare_summary]
)
# ── TAB 3: Experiment Reference ──────────────────────
with gr.Tab("📖 Experiment Reference"):
gr.Markdown("""
# Experiment Reference Guide
## System Architecture
**Hybrid Score = 0.50 × Structured + 0.30 × Semantic + 0.20 × Standards**
The structured score reads **structured columns** (`voltage_rating`, `core_count`, `size_sqmm`, etc.)
NOT the raw spec text — this is the core innovation.
---
## EXP1 — Numeric Sensitivity
**Dataset:** `rfp_specs_numeric_perturbation.csv`
Numbers in `spec_text_raw` are WRONG (11kV → 33kV, 240sqmm → 185sqmm, 3C → 4C).
Structured columns remain correct.
**Finding:** Hybrid Top-1 barely drops; SBERT drops >30 pts because it reads the text.
---
## EXP2 — Unit Variation
**Dataset:** `rfp_specs_unit_variation.csv`
Same meaning, different notation: `11kV` vs `11000V`, `sqmm` vs `mm²`, `3C` vs `3 Core`.
**Finding:** Hybrid is unit-aware by construction. SBERT is confused by token differences.
---
## EXP3 — Missing Parameters
**Dataset:** `rfp_specs_missing_specs.csv`
1–4 token types randomly dropped from `spec_text_raw`. Structured columns intact.
40.1% of rows drop at least one mandatory field.
**Finding:** Hybrid degrades minimally. SBERT loses critical embedding signal.
---
## EXP4 — Noise Injection
**Datasets:** In-domain (engineering boilerplate) + Out-of-domain (Bollywood/cricket)
~10 words prepended to spec text.
**Finding:** Out-of-domain noise hurts SBERT more; Hybrid unchanged (structured immune).
---
## EXP5 — Long Document Bias
**Dataset:** `rfp_specs_long_doc_noise.csv`
500–1300 word documents with spec buried inside (early/middle/late positions).
**Finding:** SBERT 512-token limit truncates long docs. Hybrid unaffected.
---
## EXP6 — Partial Specification
**Synthetic:** Generated in-notebook at 4/2/1 token completeness levels.
**Finding:** Hybrid maintains performance until Level 3 (1 token). SBERT drops at Level 2.
---
## EXP7 — Positional Bias
**Dataset:** `rfp_specs_positional_shift.csv`
Spec text placed at START, MIDDLE, or END of 22-31 word document.
**Finding:** SBERT has primacy bias. Hybrid structured score is position-invariant.
---
## Models Compared
| Model | Type | Notes |
|---|---|---|
| **Hybrid (MPNet)** | Structured + Semantic + Standards | Best overall across all 7 EXPs |
| MiniLM | SBERT only | Fast but sensitive to perturbations |
| TF-IDF | Lexical | Good for exact-match tokens |
| BM25 | Lexical | Probabilistic; better than TF-IDF on short queries |
*This prototype uses MiniLM for speed; the full system uses all-mpnet-base-v2.*
""")
# ── Footer ───────────────────────────────────────────────
gr.HTML("""
<div style="text-align:center; margin-top:20px; color:#888; font-size:0.85em;">
RFP Cable Spec Matcher &nbsp;|&nbsp; Major Project Prototype &nbsp;|&nbsp;
Hybrid Retrieval: Structured + Semantic + Standards
</div>
""")
if __name__ == "__main__":
demo.launch(share=False, server_name="0.0.0.0", server_port=7860)