Spaces:
Runtime error
Runtime error
Fix: build SAM2 on CPU then .to(device) - Hydra construction fails under ZeroGPU CUDA emulation
Browse files- src/service/pipeline.py +8 -1
src/service/pipeline.py
CHANGED
|
@@ -57,7 +57,14 @@ florence_processor = AutoProcessor.from_pretrained(FLORENCE_ID, trust_remote_cod
|
|
| 57 |
clip_model = CLIPModel.from_pretrained(CLIP_ID).to(DEVICE)
|
| 58 |
clip_processor = CLIPProcessor.from_pretrained(CLIP_ID)
|
| 59 |
|
| 60 |
-
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 61 |
|
| 62 |
sd_pipe = StableDiffusionInpaintPipeline.from_pretrained(
|
| 63 |
SD_INPAINT_ID, torch_dtype=torch.float16
|
|
|
|
| 57 |
clip_model = CLIPModel.from_pretrained(CLIP_ID).to(DEVICE)
|
| 58 |
clip_processor = CLIPProcessor.from_pretrained(CLIP_ID)
|
| 59 |
|
| 60 |
+
# Construction sur CPU puis .to(DEVICE) explicite, plutot que
|
| 61 |
+
# device=DEVICE directement au constructeur : le chargement de SAM2 passe
|
| 62 |
+
# par Hydra (instantiate recursif + deepcopy de la config), qui echoue sous
|
| 63 |
+
# l'emulation CUDA de ZeroGPU (RuntimeError "tensors on cuda:0 (ZeroGPU) and
|
| 64 |
+
# cpu" pendant la construction). Un .to() simple sur le module deja construit
|
| 65 |
+
# est, lui, le pattern explicitement supporte par cette emulation.
|
| 66 |
+
sam2_predictor = SAM2ImagePredictor.from_pretrained(SAM2_ID, device="cpu")
|
| 67 |
+
sam2_predictor.model.to(DEVICE)
|
| 68 |
|
| 69 |
sd_pipe = StableDiffusionInpaintPipeline.from_pretrained(
|
| 70 |
SD_INPAINT_ID, torch_dtype=torch.float16
|