Spaces:
Running on T4
Running on T4
File size: 7,522 Bytes
2426de8 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 | # Measured swing details and measurement coverage
Read **`product.objective_feedback`** from the existing `/product` endpoint.
Combined products use `schema_version: "1.2"`. Engine result, timing and coach
contracts remain unchanged. Annotated swing clips still appear in `product.swings`.
The main screen now uses engine calculations and recording timestamps. Gemini
supplies optional short visual notes; it does not supply the displayed numbers,
grades, coverage percentage, faults or drills. Model/event accuracy remains
unvalidated: a reproducible calculation can still depend on a mistaken detection.
## What gets measured
The fixed `objective-details-v1` definition requests seven values per swing:
| Feature | Key | Calculation and meaning |
| --- | --- | --- |
| Load and timing | `load_to_swing_ms` | Detected backward hand preparation to detected forward hand movement, using capture timestamps. |
| Load and timing | `foot_down_to_swing_ms` | Forward hand start minus estimated front-foot landing. Signed: positive is after landing. If the sensitivity interval crosses zero, the order is unresolved. |
| Load and timing | `swing_duration_ms` | Forward hand start to separately observed ball interaction, or calibrated closest approach for a miss. Arm extension cannot supply the end. |
| Load and timing | `early_late_shift_ms` | Timing-only correction of recorded bat/ball paths when the necessary calibrated geometry is available. A one-camera projected near miss cannot supply it. |
| Hips and shoulders | `hip_shoulder_separation_foot_plant_deg` | Accepted 3D hip/shoulder landmark-line separation at foot settling. This is a landmark construction, not a clinically validated axial rotation. |
| Bat path and contact | `bat_image_axis_rotation_deg` | Signed change of independently detected 2D shaft directions across forward-hand-start to arm-extension frames. Fixed camera and a unique shaft in every frame are required. Positive is counterclockwise on screen. |
| Bat path and contact | `contact_capture_time_s` | Midpoint of the independently supported ball-interaction time interval in the original recording. The full interval is included. |
The bat-shaft value is **image-plane geometry**, not 3D attack angle, barrel path,
bat speed or contact quality. Its axis is undirected (modulo 180 degrees), and
unsampled rotations cannot be resolved. Missing shafts, competing detections,
an unverified camera or an ambiguous direction jump withhold the value.
## Coverage is availability, not a performance grade
```text
coverage = round(100 × available requested values / applicable requested values)
```
The aggregate counts measurement/swing pairs across **all detected swings**, not
just those Gemini reviewed. Each swing also has its own coverage breakdown.
For example, one available value out of seven gives **14% measurement coverage**.
It does not mean the player has a bad swing. Two clear Gemini comments cannot
create a 100/100 score. Extra reference values, moments and visual notes do not
increase coverage.
Exclude genuinely inapplicable values: landing time for a no-step swing, contact
time for a confirmed miss, timing correction for a hit, and incoming-pitch timing
correction for tee practice. Missing evidence remains in the denominator. Zero
is a legitimate available measurement. No applicable values gives a null coverage
percentage rather than an invented zero.
## Shape the app should read
```json
{
"schema_version": "1.2",
"objective_feedback": {
"schema_version": "1.0",
"calculation_version": "objective-details-v1",
"source": "engine_measurements",
"coverage": {
"name": "Measurement coverage",
"basis": "available_requested_measurements",
"definition_version": "objective-details-v1",
"value": 14,
"unit": "%",
"available_count": 1,
"applicable_count": 7,
"requested_count": 7,
"not_applicable_count": 0,
"unavailable_count": 6,
"explanation": "1 of 7 applicable measurements available (14%).",
"meaning": "Measurement availability only. This does not rate the swing or establish measurement accuracy."
}
}
}
```
That is a response excerpt. The complete report also includes
`median_capture_frame_interval_ms`, `notice` and `reps`. Every rep contains:
- `rep`, matching the existing annotated clip's rep number.
- `coverage`, using the same availability-count shape.
- `features[]`, with `key`, `label` and `measurements[]`.
- `moments[]`, with the original frame, capture time, playback time, time inside
its preview clip, method, and an explicit `is_contact_proxy` flag.
- `references[]`, extra projected/legacy estimates excluded from coverage.
Every measurement contains `key`, `label`, `value`, `unit`, `status`, `display`,
`explanation`, `basis`, `method`, `evidence_frame_ids`, `interval`,
`interval_kind`, `reason_code`, `accuracy_validated: false` and
`judgment_eligible: false`. `status` is `estimated`, `unavailable` or
`not_applicable`. Do not convert null into zero.
Example: a landing-to-hand interval may be `333.333 ms`, displayed as
`333 ms`, with `interval: [300, 366.667]` and `interval_kind: "frame_sensitivity"`.
The range tests moving the event frames; it is not a validated accuracy bound.
Displaying milliseconds does not establish one-millisecond detection precision.
`evidence_frame_ids` refer to full engine frames. Only frames also listed in
`product.evidence.frames` have an image URL; do not invent URLs for unsampled
frames. Event `clip_playback_time_s` can be used to seek the annotated preview.
## Main screen and Gemini text
Show `objective_feedback.coverage` under the label **Measurement coverage**.
Show each rep's three feature sections using each item's `display` and
`explanation`. Keep source frames and intervals accessible. The explanations are
generated by code from the actual values, not invented by the language model.
Show `references` separately. In particular:
- Legacy stride percentages use projected body-height scaling, not calibrated
physical height or ground-plane stride distance.
- Legacy center-of-mass drift is a hip-midpoint reference, not whole-body center of mass.
- A knee angle at the lead-arm-extension proxy is not a confirmed knee angle at ball contact.
Gemini notes remain in `visual_review.features`. New reviews use
`text_style_version: "specific-observations-v2"`. Notes identify a body part,
direction and visible sequence using sampled frame references. They are visual
estimates and appear below the measured details. `rating`, `priority` and
`drill` are null in this mode. The old `visual_review.score` shape remains for
compatibility, with `value: null` and
`reason_code: "replaced_by_measurement_coverage"` for completed new reviews.
Do not display the previous experimental grade.
Measurement-based `coaching` remains available separately. Its Mechanics score
may remain null when no qualified benchmark comparison is available.
For a retained older product, explicitly call
`POST /v1/analyses/{job_id}/video-review` to build the new breakdown and refresh
the visual notes. This preserves measurements and clip hashes; image review uses
Gemini quota. A completed current-style report is returned unchanged on retries.
Existing current reports keep their measured breakdown during image-only retries.
The authenticated `/v1/objective-feedback-schema` endpoint and
[objective-feedback.schema.json](objective-feedback.schema.json) publish the
complete report structure.
|