220c87b 7a3215f 9ec8d34 fe40b87 9ec8d34 fe40b87 9ec8d34 7a3215f 9ec8d34 7a3215f 9ec8d34 7a3215f 220c87b 7a3215f 220c87b 314c3d8 220c87b 314c3d8 220c87b | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 | # Pitcher direction from two floor points
Motion API 1.14.0 · SAM 3D Body and GVHMR · 19 October 2026
## Automatic direction (default)
Updated 30 October 2026. Normal motion uploads omit `pitcher_vector`,
`pitcher_source`, and `pitcher_floor_points`. Both SAM and GVHMR now run
`automatic_body_swing_direction_v2` on their corrected 3D body tracks before
calculating/exporting measurements. The old home-plate detector is no longer
called. There are no new request fields, downloads, or user prompts.
The estimator uses shoulders, hips, and both wrists. It finds a stable loaded
setup before a hand-speed peak, projects the setup hip line onto the horizontal
plane, and resolves its direction using the loaded hand side. Both wrists must
then move across toward the other side while the hips and shoulders turn in the
same swing direction. Several consecutive setup and extension frames must agree.
V2 selects the latest five consecutive loaded setup frames that pass the existing
12-degree stability check. A longer preparation stretch can include a walk-in or
gradual body turn; its total angular spread no longer invalidates a later stable
setup. The reference uses the local interval, so earlier preparation does not
bias its heading. The selected interval and the longer search interval are both
recorded. Backward loading peaks still fail the forward-motion check; neither
that check nor the stability threshold was relaxed.
Separate accepted swings must agree within 20 degrees. Missing/rejected points,
filter boundaries, model sequence breaks, and timestamp gaps cannot connect a
setup to a later swing. Cropped feet are allowed: stride never defines the axis.
Handedness and camera intrinsics are not inputs to this estimator. Relative
movement checks do not require a physical scale or original recording speed.
An accepted vertical reference is still needed. GeoCalib supplies it when omitted;
an explicit up vector also works. Camera movement declared or detected by
refinement blocks this reference. Acceptance does not declare the camera fixed or
bypass existing camera-stability, timing, scale, or reviewed-event requirements.
On acceptance, `coordinates.pitcher_estimation` contains `automatic: true`,
`status: estimated`, the method, setup/peak/extension frame indices, turn angles,
hand progress, agreement checks and assumptions. `reference_kind` is
`estimated_batting_direction`; `target_alignment_verified` is false. Effective
`pipeline.calculation_inputs` receive the vector and generated source; submitted
`pipeline.inputs` stay unchanged. Replay and measurements use that same vector.
When the axis is used, the coordinate frame is `estimated_batting_axes`, with
positive X named `estimated_hitting_direction`. Relevant measurements carry
`pitcher_reference_estimated_from_body_motion` and `target_alignment_unverified`.
Explicit vectors and manual floor selections retain precedence.
**Limits:** this is a deterministic body-motion heuristic, not a trained baseball
direction model. It assumes the setup hip line approximately follows the intended
hitting direction. Open/closed setups, unusual drills, inaccurate model depth,
and movement that resembles a swing can bias or fool it. Body motion alone cannot
verify the actual direction to an unseen pitcher. A clipped swing without a clear
setup or extension, conflicting repetitions, or missing vertical leaves the
direction null; normal motion export continues. Do not interpret this axis as
independent evidence that the athlete's setup is aligned correctly with a target.
`accuracy_validated` stays false and `confidence` stays null. `reliable` means
the engineering acceptance checks passed, not a calibrated accuracy probability.
Synthetic tests cover both batting sides, camera rotations, missing evidence,
motion conflicts, and replay consistency. Independently labelled real videos
are still required to measure accuracy and false positives.
## Optional manual override
Use the existing `/v1/motion-analyses` upload and `/revisions` routes. Select a
decoded source frame and two points **on the same level floor**: first near the
batter, then farther along the floor toward the pitcher. They need not be at
the pitcher's feet. Their order defines the positive direction; reversing the
points reverses the vector. This is a field direction, not the ball trajectory.
## Request
Add `pitcher_floor_points` to the multipart form's `options` JSON. Example for
an **illustrative 1920 × 1080 source**, with illustrative calibration values;
use the actual camera's calibration rather than copying these numbers:
```json
{
"model": "gvhmr",
"annotated_videos": true,
"camera_stability": "fixed_verified",
"camera": {
"fx": 1100,
"fy": 1050,
"cx": 925,
"cy": 500,
"source": "Calibration procedure and recording configuration",
"calibration_status": "calibrated",
"distortion": [0, 0, 0, 0, 0]
},
"pitcher_floor_points": {
"source_frame_index": 40,
"near_batter": [650, 893.75],
"toward_pitcher": [1291.666666667, 762.5],
"selection_uncertainty_px": 2,
"up_sensitivity_deg": 1
}
}
```
Use `"model":"sam3d"` for SAM; every other field and response stays the same.
Omit `up_vector`/`up_source` to use the existing automatic GeoCalib estimate.
Alternatively supply the known camera-space up vector and its source. An
unreliable or missing up reference leaves the floor direction unknown.
| Field | Contract |
| --- | --- |
| `pitcher_floor_points` | Optional object; omit/null when no selection is available. |
| `source_frame_index` | Required, zero-based decoded **source** frame index, integer ≥ 0. Both points belong to this frame. |
| `near_batter` | Required `[x,y]`, upright original source-image pixels, first point. |
| `toward_pitcher` | Required `[x,y]`, same frame/pixel convention, second point. |
| `selection_uncertainty_px` | Optional positive perturbation radius per pixel coordinate; default 2 source pixels, maximum 25. Increase for coarse selections. This is a sensitivity assumption, not measured click accuracy. |
| `up_sensitivity_deg` | Optional positive up-direction perturbation angle; default 1°, maximum 30°. For estimated up, the calculation uses at least the model uncertainty plus frame disagreement; this field cannot lower that test. |
| `camera.calibration_status` | New motion-only field: `unknown` (default), `estimated`, or `calibrated`. Floor direction requires `calibrated`; set this only for calibration that applies to this recording's upright image, crop, resolution, zoom and lens configuration. |
| `camera.fx/fy/cx/cy/source` | Existing camera calibration fields. Focal lengths and principal point are in upright source-image pixels. A source description is required. |
| `camera.distortion` | Existing optional Brown–Conrady `[k1,k2,p1,p2,k3]`. Omitted/null means a pinhole assumption; use it only when appropriate for the calibrated source. |
| `pitcher_vector/pitcher_source` | Existing manual override. When supplied, it wins over floor points, even if floor points/calibration would be unusable. Original values and magnitude stay unchanged. |
`calibration_status` does not change existing body reconstruction or up
estimation. Older motion requests continue to work, defaulting it to `unknown`;
they cannot silently promote a guessed focal length into floor calibration.
For this manual floor-point path, SAM/GVHMR body-model intrinsics and GeoCalib's
internal focal estimate are not substituted for the required declared calibration. This option belongs to the
motion API; legacy SAM/coaching request contracts remain separate.
## Frontend coordinate mapping
Use `source_video.display_width/display_height` and the upright source frame.
Coordinates are **not** CSS pixels, raw rotated-file pixels, the skeleton's
3D coordinates, or the smaller annotated-video dimensions. Account for preview
scaling, cropping, and letterboxing:
```text
x_source = (x_in_preview - content_left) * source_width / content_width
y_source = (y_in_preview - content_top) * source_height / content_height
```
Undo any frontend-only mirror transform before sending coordinates. The backend
does not mirror selections. Select the source-frame index using the returned
frame records and actual source/video timestamps; do not calculate it from
`currentTime * FPS`, because the recording can have variable frame timing.
Both points must come from the same displayed frame and actually touch the floor,
not a knee, elevated tee, distant wall, or projected line above the ground.
To add or correct points after an analysis, submit:
```json
{
"options": {
"pitcher_floor_points": {
"source_frame_index": 40,
"near_batter": [650, 893.75],
"toward_pitcher": [1291.666666667, 762.5]
},
"pitcher_vector": null,
"pitcher_source": null
}
}
```
Send this to `POST /v1/motion-analyses/{job_id}/revisions`. Clearing a previous
manual vector is necessary to enable floor estimation. Existing calibration and
other recording facts are inherited. The parent stays immutable. Point-only
changes can reuse verified native inference; calibration changes may require
new inference. To remove the selection, revise `pitcher_floor_points` to null.
## Response
Read the completed manifest's `coordinates`. The following is an illustrative
excerpt; actual vectors and diagnostics depend on the recording and selection:
```json
{
"pitcher_vector": [0.8320502943, 0, 0.5547001962],
"pitcher_source": "Two user-selected floor points at source frame 40; calibrated ray-plane intersection with level floor and camera above floor (estimated)",
"pitcher_vector_frame": "upright_camera_x_right_y_down_z_away",
"pitcher_estimation": {
"status": "estimated",
"method": "two_floor_points_ray_plane_v1",
"applied": true,
"reliable": true,
"confidence": null,
"accuracy_validated": false,
"reason_code": null
}
}
```
The full `pitcher_estimation` also repeats its vector/source. Additional
diagnostics are present when their validation stage was reached; they are
optional for unknown results:
- `selection` and `source_frame`: original selection, actual source-frame index,
dimensions, PTS/time base and video timestamp.
- `camera_calibration`, `up_vector_used`, `up_reference_status`: inputs used by
the geometry. The up vector here is normalized for calculation.
- `ray_floor_incidence_deg`, `pixel_separation_px`,
`maximum_undistortion_residual_px`: geometric checks.
- `up_sensitivity_deg_used`, `maximum_direction_deviation_deg`,
`evaluated_scenarios`, `sensitivity_kind`, and `limits`: sensitivity diagnostics
and the acceptance thresholds.
- `assumptions`, `floor_points_verified_by_backend: false`,
`calibration_accuracy_verified_by_backend: false`, and the implementation hash.
Display **Estimated pitcher direction** for `status: estimated`. Derived vectors
are normalized and in camera axes **x right, y down, z away**. They are not in
the rotated skeleton/export axes. `reliable: true` means the conditional
engineering checks passed; it is not a probability or independent accuracy
validation. Keep `confidence: null` as unknown, not 0%.
For `provided`, display **User-supplied pitcher direction**. The vector/source
remain exact, `method` is `caller_supplied`, and `reliable` is null. For `unknown`,
both effective vector and source are null, `applied/reliable` are false, and
`reason_code` explains why. Do not turn the 2D arrow into a substitute vector.
Older cached manifests may omit these new keys. Treat an absent reference as
unknown and offer a new analysis/revision; do not rewrite an immutable result.
Original validated facts remain in `pipeline.inputs`; the derived vector/source
are added only to `pipeline.calculation_inputs`. The same reference is included
as `pitcher_reference` in measurement and quality artifacts. Measurement summaries
and series contain `pitcher_reference_status`; available field-axis-dependent
summaries carry `pitcher_reference_estimated_from_floor_points`.
Accepted direction sets the measurement/export X axis toward the pitcher. The
existing frame identifier `declared_field_axes` remains for compatibility;
`pitcher_estimation.status` records whether that field axis was derived or
manually provided. Measurements and public-artifact reproduction use the same
effective reference. Physical clock, body-point quality, scale, reviewed events,
and other measurement guards still apply. This direction does not provide ground
positions, camera height, floor distances, or a calibrated ground trajectory.
## Calculation and rejection checks
Undistort the two pixels using the supplied calibration, then form optical rays
`r = [x_normalized, y_normalized, 1]`. With normalized camera-up `u` and a camera
at positive unknown height `h` above the level floor, the floor plane is
`u·X = -h`. Each hit is `X = -h*r/(u·r)`. Therefore:
```text
q_near = -r_near / dot(u, r_near)
q_toward = -r_toward / dot(u, r_toward)
pitcher_vector = normalize(q_toward - q_near)
```
Height cancels, while perspective and the first-to-second sign are retained.
Subtracting raw pixel positions or projecting a 2D arrow onto the floor is not
this calculation. Pixel/ray and distortion conventions follow the
[OpenCV camera model](https://docs.opencv.org/4.x/d9/d0c/group__calib3d.html).
Acceptance requires fixed verified camera orientation, no observed static-camera
conflict, a valid source index, consistent source dimensions, in-image points
at least 10 pixels apart, declared calibrated intrinsics, plausible focal/principal
point values, finite monotonic distortion geometry, ≤ 0.1-pixel undistortion
round-trip error, and both floor rays at least 3° below the horizon.
The backend perturbs each click coordinate by its selection uncertainty and
samples an up-direction cone at 16 azimuths plus its center: 289 combined
scenarios. Every sampled ray must still hit a well-conditioned visible floor;
the maximum direction change must be ≤ 10°. These are engineering gates, not
guaranteed error bounds. A consistent wrong calibration, wrong up direction,
sloping/nonplanar floor, or a tap on an elevated object can still produce a wrong
direction. The backend cannot establish those facts from two clicks.
Common unknown reasons:
| `reason_code` | FE action |
| --- | --- |
| `floor_points_not_supplied` | Offer the two-point selection. |
| `floor_source_frame_out_of_range` | Re-select a source frame from this recording. |
| `floor_points_outside_source_image` | Correct preview-to-source coordinate mapping. |
| `floor_point_uncertainty_outside_source_image` | Select points farther from image borders. |
| `floor_points_too_close` | Select floor points farther apart. |
| `floor_points_not_below_horizon` | Select visible floor below the horizon; check up/calibration. |
| `floor_points_too_near_horizon` | Choose nearer, better-conditioned floor points. |
| `camera_not_fixed_for_pitcher_reference` | Verify a fixed recording or re-record with a fixed camera. |
| `source_image_dimensions_changed` | Supply a recording/calibration with consistent source dimensions. |
| `pitcher_camera_calibration_missing` | Provide applicable camera calibration. |
| `pitcher_camera_calibration_unverified` | Use verified calibration; do not relabel guessed intrinsics. |
| `pitcher_camera_calibration_implausible` | Check focal lengths, principal point, crop and resolution. |
| `camera_undistortion_unreliable`, `camera_distortion_not_monotonic` | Check the lens model/calibration. |
| `pitcher_up_reference_unknown`, `pitcher_up_reference_unreliable`, `pitcher_up_uncertainty_unknown` | Resolve the up reference before estimating direction. |
| `floor_direction_uncertainty_unreliable`, `floor_direction_uncertainty_too_high` | Use a better-separated selection away from the horizon; check up/calibration. |
| `floor_direction_geometry_failed`, `invalid_direction_geometry` | Recheck the selection and calibration. |
Geometrically unusable inputs leave this reference unknown without failing an
otherwise usable motion analysis. Malformed JSON/options still return 422;
ordinary upload, native-model, queue and artifact errors keep their existing
semantics. Capabilities expose `pitcher_direction_from_floor_points`.
|