mosta02 commited on
Commit
aa0d70b
Β·
verified Β·
1 Parent(s): 926241f

Upload centerline_extraction.py

Browse files
Files changed (1) hide show
  1. centerline_extraction.py +30 -5
centerline_extraction.py CHANGED
@@ -1438,6 +1438,30 @@ def label_aorta_vs_arteries(segments, all_bifurcations, point_to_segments, preco
1438
  else:
1439
  n_keep = 1
1440
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1441
  # ── Apply labels ────────────────────────────────────────────────────
1442
  for i, (c, avg_r) in enumerate(aorta_ranked):
1443
  seg = segments[c['seg_idx']]
@@ -1493,16 +1517,17 @@ def label_aorta_vs_arteries(segments, all_bifurcations, point_to_segments, preco
1493
 
1494
  # ── Step 4: Detect iliac cutoff from labeled topology ─────────────────────
1495
  # Strategy: after full labeling, the iliac cutoff is the lowest-Z validated
1496
- # junction that has at least one confirmed-Aorta arm AND at least one Artery
1497
- # arm. Using the minimum Z eliminates false matches at upper-aorta (thoracic
1498
- # or renal) junctions β€” those always sit at higher Z than the iliac Y.
 
 
1499
  iliac_cutoff = None
1500
  cutoff_candidates = []
1501
  for bif_id, (bif, connections) in valid_bifs.items():
1502
  seg_indices = [c['seg_idx'] for c in connections]
1503
  has_confirmed_aorta = any(segments[si].get('confirmed_aorta') for si in seg_indices)
1504
- has_artery = any(segments[si]['label'] == 'Artery' for si in seg_indices)
1505
- if has_confirmed_aorta and has_artery:
1506
  cutoff_candidates.append(bif)
1507
 
1508
  if cutoff_candidates:
 
1438
  else:
1439
  n_keep = 1
1440
 
1441
+ # ── Guard: confirmed-aorta threshold check ───────────────────────────
1442
+ # The gap analysis (3+ arms) can mis-promote an iliac leg to
1443
+ # confirmed_aorta when the ext-iliac→int-iliac gap > trunk→ext-iliac gap
1444
+ # (e.g. trunk=10, ext=7, int=3 β†’ gaps [3,4] β†’ n_keep=2, WRONG).
1445
+ # Fix: if any confirmed arm is among the top-n_keep group, every
1446
+ # non-confirmed arm we would keep must still satisfy the ratio check
1447
+ # relative to the confirmed arm's radius β€” the same guard used for 2-arm
1448
+ # junctions. This correctly reduces n_keep to 1 at the iliac Y while
1449
+ # leaving legitimate aorta-to-aorta continuations (ratio β‰₯ 0.75) intact.
1450
+ if n_keep > 1:
1451
+ r_conf_max = max(
1452
+ (r for c, r in aorta_ranked[:n_keep]
1453
+ if segments[c['seg_idx']].get('confirmed_aorta')),
1454
+ default=0,
1455
+ )
1456
+ if r_conf_max > 0:
1457
+ for i in range(n_keep - 1, 0, -1):
1458
+ c_i, r_i = aorta_ranked[i]
1459
+ if (not segments[c_i['seg_idx']].get('confirmed_aorta')
1460
+ and r_i < AORTA_CONTINUATION_RATIO * r_conf_max):
1461
+ n_keep = i
1462
+ break
1463
+ n_keep = max(1, n_keep)
1464
+
1465
  # ── Apply labels ────────────────────────────────────────────────────
1466
  for i, (c, avg_r) in enumerate(aorta_ranked):
1467
  seg = segments[c['seg_idx']]
 
1517
 
1518
  # ── Step 4: Detect iliac cutoff from labeled topology ─────────────────────
1519
  # Strategy: after full labeling, the iliac cutoff is the lowest-Z validated
1520
+ # junction that touches at least one confirmed-Aorta arm. The main trunk has
1521
+ # confirmed_aorta=True; its terminal junction (the iliac Y) is the most
1522
+ # caudal such junction. We intentionally do NOT require an Artery arm here β€”
1523
+ # if both iliac legs were mislabeled Aorta by BFS, has_artery would be False
1524
+ # and we'd fall through to a higher (wrong) junction.
1525
  iliac_cutoff = None
1526
  cutoff_candidates = []
1527
  for bif_id, (bif, connections) in valid_bifs.items():
1528
  seg_indices = [c['seg_idx'] for c in connections]
1529
  has_confirmed_aorta = any(segments[si].get('confirmed_aorta') for si in seg_indices)
1530
+ if has_confirmed_aorta:
 
1531
  cutoff_candidates.append(bif)
1532
 
1533
  if cutoff_candidates: