File size: 202,299 Bytes
a11dc31
1
[{"i":0,"id":"cfr/1910.1","section_id":"cfr/1910.1","title":"29 CFR 1910.1 Purpose and scope","heading":"Purpose and scope","text":"(a) Section 6(a) of the Williams-Steiger Occupational Safety and Health Act of 1970 (84 Stat. 1593) provides that \u201cwithout regard to chapter 5 of title 5, United States Code, or to the other subsections of this section, the Secretary shall, as soon as practicable during the period beginning with the effective date of this Act and ending 2 years after such date, by rule promulgate as an occupational safety or health standard any national concensus standard, and any established Federal standard, unless he determines that the promulgation of such a standard would not result in improved safety or health for specifically designated employees.\u201d The legislative purpose of this provision is to establish, as rapidly as possible and without regard to the rule-making provisions of the Administrative Procedure Act, standards with which industries are generally familiar, and on whose adoption interested and affected persons have already had an oppor","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1","vehicles":[]},{"i":1,"id":"cfr/1910.1000","section_id":"cfr/1910.1000","title":"29 CFR 1910.1000 Air contaminants","heading":"Air contaminants","text":"An employee's exposure to any substance listed in Tables Z-1, Z-2, or Z-3 of this section shall be limited in accordance with the requirements of the following paragraphs of this section. (a) Table Z-1 \u2014(1) Substances with limits preceded by \u201cC\u201d\u2014Ceiling Values. An employee's exposure to any substance in Table Z-1, the exposure limit of which is preceded by a \u201cC\u201d, shall at no time exceed the exposure limit given for that substance. If instantaneous monitoring is not feasible, then the ceiling shall be assessed as a 15-minute time weighted average exposure which shall not be exceeded at any time during the working day. (2) Other substances\u20148-hour Time Weighted Averages. An employee's exposure to any substance in Table Z-1, the exposure limit of which is not preceded by a \u201cC\u201d, shall not exceed the 8-hour Time Weighted Average given for that substance in any 8-hour work shift of a 40-hour work week. (b) Table Z-2. An employee's exposure to ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1000","vehicles":[]},{"i":2,"id":"cfr/1910.1001","section_id":"cfr/1910.1001","title":"29 CFR 1910.1001 Asbestos","heading":"Asbestos","text":"(a) Scope and application. (1) This section applies to all occupational exposures to asbestos in all industries covered by the Occupational Safety and Health Act, except as provided in paragraph (a)(2) and (3) of this section. (2) This section does not apply to construction work as defined in 29 CFR 1910.12(b). (Exposure to asbestos in construction work is covered by 29 CFR 1926.1101). (3) This section does not apply to ship repairing, shipbuilding and shipbreaking employments and related employments as defined in 29 CFR 1915.4. (Exposure to asbestos in these employments is covered by 29 CFR 1915.1001). (b) Definitions. Asbestos includes chrysotile, amosite, crocidolite, tremolite asbestos, anthophyllite asbestos, actinolite asbestos, and any of these minerals that have been chemically treated and/or altered. Asbestos-containing material (ACM) means any material containing more than 1% asbestos. Assistant Secretary means the Assistant S","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1001","vehicles":[]},{"i":3,"id":"cfr/1910.1002","section_id":"cfr/1910.1002","title":"29 CFR 1910.1002 Coal tar pitch volatiles; interpretation of term","heading":"Coal tar pitch volatiles; interpretation of term","text":"As used in \u00a7 1910.1000 (Table Z-1), coal tar pitch volatiles include the fused polycyclic hydrocarbons which volatilize from the distillation residues of coal, petroleum (excluding asphalt), wood, and other organic matter. Asphalt (CAS 8052-42-4, and CAS 64742-93-4) is not covered under the \u201ccoal tar pitch volatiles\u201d standard. [48 FR 2768, Jan. 21, 1983]","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1002","vehicles":[]},{"i":4,"id":"cfr/1910.1003","section_id":"cfr/1910.1003","title":"29 CFR 1910.1003 13 Carcinogens (4-Nitrobiphenyl, etc.)","heading":"13 Carcinogens (4-Nitrobiphenyl, etc.)","text":"(a) Scope and application. (1) This section applies to any area in which the 13 carcinogens addressed by this section are manufactured, processed, repackaged, released, handled, or stored, but shall not apply to transshipment in sealed containers, except for the labeling requirements under paragraphs (e)(2), (3) and (4) of this section. The 13 carcinogens are the following: 4-Nitrobiphenyl, Chemical Abstracts Service Register Number (CAS No.) 92933; alpha-Naphthylamine, CAS No. 134327; methyl chloromethyl ether, CAS No. 107302; 3,\u2032-Dichlorobenzidine (and its salts) CAS No. 91941; bis-Chloromethyl ether, CAS No. 542881; beta-Naphthylamine, CAS No. 91598; Benzidine, CAS No. 92875; 4-Aminodiphenyl, CAS No. 92671; Ethyleneimine, CAS No. 151564; beta-Propiolactone, CAS No. 57578; 2-Acetylaminofluorene, CAS No. 53963; 4-Dimethylaminoazo-benezene, CAS No. 60117; and N-Nitrosodimethylamine, CAS No. 62759. (2) This section shall not apply to the","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1003","vehicles":[]},{"i":5,"id":"cfr/1910.101","section_id":"cfr/1910.101","title":"29 CFR 1910.101 Compressed gases (general requirements)","heading":"Compressed gases (general requirements)","text":"(a) Inspection of compressed gas cylinders. Each employer shall determine that compressed gas cylinders under his control are in a safe condition to the extent that this can be determined by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous Materials Regulations of the Department of Transportation (49 CFR parts 171-179 and 14 CFR part 103). Where those regulations are not applicable, visual and other inspections shall be conducted in accordance with Compressed Gas Association Pamphlets C-6-1968 and C-8-1962, which is incorporated by reference as specified in \u00a7 1910.6. (b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in \u00a7 1910.6. (c) Safety relief device","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.101","vehicles":[]},{"i":6,"id":"cfr/1910.1017","section_id":"cfr/1910.1017","title":"29 CFR 1910.1017 Vinyl chloride","heading":"Vinyl chloride","text":"(a) Scope and application. (1) This section includes requirements for the control of employee exposure to vinyl chloride (chloroethene), Chemical Abstracts Service Registry No. 75014. (2) This section applies to the manufacture, reaction, packaging, repackaging, storage, handling or use of vinyl chloride or polyvinyl chloride, but does not apply to the handling or use of fabricated products made of polyvinyl chloride. (3) This section applies to the transportation of vinyl chloride or polyvinyl chloride except to the extent that the Department of Transportation may regulate the hazards covered by this section. (b) Definitions \u2014(1) Action level means a concentration of vinyl chloride of 0.5 ppm averaged over an 8-hour work day. (2) Assistant Secretary means the Assistant Secretary of Labor for Occupational Safety and Health, U.S. Department of Labor, or his designee. (3) Authorized person means any person specifically authorized by the e","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1017","vehicles":[]},{"i":7,"id":"cfr/1910.1018","section_id":"cfr/1910.1018","title":"29 CFR 1910.1018 Inorganic arsenic","heading":"Inorganic arsenic","text":"(a) Scope and application. This section applies to all occupational exposures to inorganic arsenic except that this section does not apply to employee exposures in agriculture or resulting from pesticide application, the treatment of wood with preservatives or the utilization of arsenically preserved wood. (b) Definitions. Action level means a concentration of inorganic arsenic of 5 micrograms per cubic meter of air (5 \u00b5g/m 3 ) averaged over any eight (8) hour period. Assistant Secretary means the Assistant Secretary of Labor for Occupational Safety and Health, U.S. Department of Labor, or designee. Authorized person means any person specifically authorized by the employer whose duties require the person to enter a regulated area, or any person entering such an area as a designated representative of employees for the purpose of exercising the right to observe monitoring and measuring procedures under paragraph (e) of this section. Direc","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1018","vehicles":[]},{"i":8,"id":"cfr/1910.102","section_id":"cfr/1910.102","title":"29 CFR 1910.102 Acetylene","heading":"Acetylene","text":"(a) Cylinders. Employers must ensure that the in-plant transfer, handling, storage, and use of acetylene in cylinders comply with the provisions of CGA Pamphlet G-1-2009 (\u201cAcetylene\u201d) (incorporated by reference, see \u00a7 1910.6). (b) Piped systems. (1) Employers must comply with Chapter 9 (\u201cAcetylene Piping\u201d) of NFPA 51A-2006 (\u201cStandard for Acetylene Charging Plants\u201d) (National Fire Protection Association, 2006 ed., 2006). (2) When employers can demonstrate that the facilities, equipment, structures, or installations used to generate acetylene or to charge (fill) acetylene cylinders were installed prior to February 16, 2006, these employers may comply with the provisions of Chapter 7 (\u201cAcetylene Piping\u201d) of NFPA 51A-2001 (\u201cStandard for Acetylene Charging Plants\u201d) (National Fire Protection Association, 2001 ed., 2001). (3) The provisions of \u00a7 1910.102(b)(2) also apply when the facilities, equipment, structures, or installations used to gene","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.102","vehicles":[]},{"i":9,"id":"cfr/1910.1020","section_id":"cfr/1910.1020","title":"29 CFR 1910.1020 Access to employee exposure and medical records","heading":"Access to employee exposure and medical records","text":"(a) Purpose. The purpose of this section is to provide employees and their designated representatives a right of access to relevant exposure and medical records; and to provide representatives of the Assistant Secretary a right of access to these records in order to fulfill responsibilities under the Occupational Safety and Health Act. Access by employees, their representatives, and the Assistant Secretary is necessary to yield both direct and indirect improvements in the detection, treatment, and prevention of occupational disease. Each employer is responsible for assuring compliance with this section, but the activities involved in complying with the access to medical records provisions can be carried out, on behalf of the employer, by the physician or other health care personnel in charge of employee medical records. Except as expressly provided, nothing in this section is intended to affect existing legal and ethical obligations con","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1020","vehicles":[]},{"i":10,"id":"cfr/1910.1024","section_id":"cfr/1910.1024","title":"29 CFR 1910.1024 Beryllium","heading":"Beryllium","text":"(a) Scope and application. (1) This standard applies to occupational exposure to beryllium in all forms, compounds, and mixtures in general industry, except those articles and materials exempted by paragraphs (a)(2) and (a)(3) of this standard. (2) This standard does not apply to articles, as defined in the Hazard Communication standard (HCS) (\u00a7 1910.1200(c)), that contain beryllium and that the employer does not process. (3) This standard does not apply to materials containing less than 0.1% beryllium by weight where the employer has objective data demonstrating that employee exposure to beryllium will remain below the action level as an 8-hour TWA under any foreseeable conditions. (b) Definitions. As used in this standard: Action level means a concentration of airborne beryllium of 0.1 micrograms per cubic meter of air (\u00b5g/m 3 ) calculated as an 8-hour time-weighted average (TWA). Airborne exposure and airborne exposure to beryllium m","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1024","vehicles":[]},{"i":11,"id":"cfr/1910.1025","section_id":"cfr/1910.1025","title":"29 CFR 1910.1025 Lead","heading":"Lead","text":"(a) Scope and application. (1) This section applies to all occupational exposure to lead, except as provided in paragraph (a)(2). (2) This section does not apply to the construction industry or to agricultural operations covered by 29 CFR part 1928. (b) Definitions. Action level means employee exposure, without regard to the use of respirators, to an airborne concentration of lead of 30 micrograms per cubic meter of air (30 \u00b5g/m 3 ) averaged over an 8-hour period. Assistant Secretary means the Assistant Secretary of Labor for Occupational Safety and Health, U.S. Department of Labor, or designee. Director means the Director, National Institute for Occupational Safety and Health (NIOSH), U.S. Department of Health, Education, and Welfare, or designee. Lead means metallic lead, all inorganic lead compounds, and organic lead soaps. Excluded from this definition are all other organic lead compounds. (c) Permissible exposure limit (PEL). (1) T","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1025","vehicles":[]},{"i":12,"id":"cfr/1910.1026","section_id":"cfr/1910.1026","title":"29 CFR 1910.1026 Chromium (VI)","heading":"Chromium (VI)","text":"(a) Scope. (1) This standard applies to occupational exposures to chromium (VI) in all forms and compounds in general industry, except: (2) Exposures that occur in the application of pesticides regulated by the Environmental Protection Agency or another Federal government agency (e.g., the treatment of wood with preservatives); (3) Exposures to portland cement; or (4) Where the employer has objective data demonstrating that a material containing chromium or a specific process, operation, or activity involving chromium cannot release dusts, fumes, or mists of chromium (VI) in concentrations at or above 0.5 \u00b5gm/m 3 as an 8-hour time-weighted average (TWA) under any expected conditions of use. (b) Definitions. For the purposes of this section the following definitions apply: Action level means a concentration of airborne chromium (VI) of 2.5 micrograms per cubic meter of air (2.5 \u00b5gm/m 3 ) calculated as an 8-hour time-weighted average (TWA","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1026","vehicles":[]},{"i":13,"id":"cfr/1910.1027","section_id":"cfr/1910.1027","title":"29 CFR 1910.1027 Cadmium","heading":"Cadmium","text":"(a) Scope. This standard applies to all occupational exposures to cadmium and cadmium compounds, in all forms, and in all industries covered by the Occupational Safety and Health Act, except the construction-related industries, which are covered under 29 CFR 1926.63. (b) Definitions. Action level (AL) is defined as an airborne concentration of cadmium of 2.5 micrograms per cubic meter of air (2.5 \u00b5g/m 3 ), calculated as an 8-hour time-weighted average (TWA). Assistant Secretary means the Assistant Secretary of Labor for Occupational Safety and Health, U.S. Department of Labor, or designee. Authorized person means any person authorized by the employer and required by work duties to be present in regulated areas or any person authorized by the OSH Act or regulations issued under it to be in regulated areas. Director means the Director of the National Institute for Occupational Safety and Health (NIOSH), U.S. Department of Health and Human","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1027","vehicles":[]},{"i":14,"id":"cfr/1910.1028","section_id":"cfr/1910.1028","title":"29 CFR 1910.1028 Benzene","heading":"Benzene","text":"(a) Scope and application. (1) This section applies to all occupational exposures to benzene. Chemical Abstracts Service Registry No. 71-43-2, except as provided in paragraphs (a)(2) and (a)(3) of this section. (2) This section does not apply to: (i) The storage, transportation, distribution, dispensing, sale or use of gasoline, motor fuels, or other fuels containing benzene subsequent to its final discharge from bulk wholesale storage facilities, except that operations where gasoline or motor fuels are dispensed for more than 4 hours per day in an indoor location are covered by this section. (ii) Loading and unloading operations at bulk wholesale storage facilities which use vapor control systems for all loading and unloading operations, except for the provisions of 29 CFR 1910.1200 as incorporated into this section and the emergency provisions of paragraphs (g) and (i)(4) of this section. (iii) The storage, transportation, distributio","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1028","vehicles":[]},{"i":15,"id":"cfr/1910.1029","section_id":"cfr/1910.1029","title":"29 CFR 1910.1029 Coke oven emissions","heading":"Coke oven emissions","text":"(a) Scope and application. This section applies to the control of employee exposure to coke oven emissions, except that this section shall not apply to working conditions with regard to which other Federal agencies exercise statutory authority to prescribe or enforce standards affecting occupational safety and health. (b) Definitions. For the purpose of this section: Authorized person means any person specifically authorized by the employer whose duties require the person to enter a regulated area, or any person entering such an area as a designated representative of employees for the purpose of exercising the opportunity to observe monitoring and measuring procedures under paragraph (n) of this section. Beehive oven means a coke oven in which the products of carbonization other than coke are not recovered, but are released into the ambient air. Coke oven means a retort in which coke is produced by the destructive distillation or carbon","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1029","vehicles":[]},{"i":16,"id":"cfr/1910.103","section_id":"cfr/1910.103","title":"29 CFR 1910.103 Hydrogen","heading":"Hydrogen","text":"(a) General \u2014(1) Definitions. As used in this section (i) Gaseous hydrogen system is one in which the hydrogen is delivered, stored and discharged in the gaseous form to consumer's piping. The system includes stationary or movable containers, pressure regulators, safety relief devices, manifolds, interconnecting piping and controls. The system terminates at the point where hydrogen at service pressure first enters the consumer's distribution piping. (ii) Approved\u2014Means, unless otherwise indicated, listed or approved by a nationally recognized testing laboratory. Refer to \u00a7 1910.7 for definition of nationally recognized testing laboratory. (iii) Listed\u2014See \u201capproved\u201d. (iv) ASME\u2014American Society of Mechanical Engineers. (v) DOT Specifications\u2014Regulations of the Department of Transportation published in 49 CFR Chapter I. (vi) DOT regulations\u2014See \u00a7 1910.103 (a)(1)(v). (2) Scope \u2014(i) Gaseous hydrogen systems. ( a ) Paragraph (b) of this sect","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.103","vehicles":[]},{"i":17,"id":"cfr/1910.1030","section_id":"cfr/1910.1030","title":"29 CFR 1910.1030 Bloodborne pathogens","heading":"Bloodborne pathogens","text":"(a) Scope and Application. This section applies to all occupational exposure to blood or other potentially infectious materials as defined by paragraph (b) of this section. (b) Definitions. For purposes of this section, the following shall apply: Assistant Secretary means the Assistant Secretary of Labor for Occupational Safety and Health, or designated representative. Blood means human blood, human blood components, and products made from human blood. Bloodborne Pathogens means pathogenic microorganisms that are present in human blood and can cause disease in humans. These pathogens include, but are not limited to, hepatitis B virus (HBV) and human immunodeficiency virus (HIV). Clinical Laboratory means a workplace where diagnostic or other screening procedures are performed on blood or other potentially infectious materials. Contaminated means the presence or the reasonably anticipated presence of blood or other potentially infectious","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1030","vehicles":[]},{"i":18,"id":"cfr/1910.104","section_id":"cfr/1910.104","title":"29 CFR 1910.104 Oxygen","heading":"Oxygen","text":"(a) Scope. This section applies to the installation of bulk oxygen systems on industrial and institutional consumer premises. This section does not apply to oxygen manufacturing plants or other establishments operated by the oxygen supplier or his agent for the purpose of storing oxygen and refilling portable containers, trailers, mobile supply trucks, or tank cars, nor to systems having capacities less than those stated in paragraph (b)(1) of this section. (b) Bulk oxygen systems \u2014(1) Definition. As used in this section: A bulk oxygen system is an assembly of equipment, such as oxygen storage containers, pressure regulators, safety devices, vaporizers, manifolds, and interconnecting piping, which has storage capacity of more than 13,000 cubic feet of oxygen, Normal Temperature and Pressure (NTP), connected in service or ready for service, or more than 25,000 cubic feet of oxygen (NTP) including unconnected reserves on hand at the site.","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.104","vehicles":[]},{"i":19,"id":"cfr/1910.1043","section_id":"cfr/1910.1043","title":"29 CFR 1910.1043 Cotton dust","heading":"Cotton dust","text":"(a) Scope and application. (1) This section, in its entirety, applies to the control of employee exposure to cotton dust in all workplaces where employees engage in yarn manufacturing, engage in slashing and weaving operations, or work in waste houses for textile operations. (2) This section does not apply to the handling or processing of woven or knitted materials; to maritime operations covered by 29 CFR Parts 1915 and 1918; to harvesting or ginning of cotton; or to the construction industry. (3) Only paragraphs (h) Medical surveillance, (k)(2) through (4) Recordkeeping\u2014Medical Records, and appendices B, C and D of this section apply in all work places where employees exposed to cotton dust engage in cottonseed processing or waste processing operations. (4) This section applies to yarn manufacturing and slashing and weaving operations exclusively using washed cotton (as defined by paragraph (n) of this section) only to the extent spec","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1043","vehicles":[]},{"i":20,"id":"cfr/1910.1044","section_id":"cfr/1910.1044","title":"29 CFR 1910.1044 1,2-dibromo-3-chloropropane","heading":"1,2-dibromo-3-chloropropane","text":"(a) Scope and application. (1) This section applies to occupational exposure to 1,2-dibromo-3-chloropropane (DBCP). (2) This section does not apply to: (i) Exposure to DBCP which results solely from the application and use of DBCP as a pesticide; or (ii) The storage, transportation, distribution or sale of DBCP in intact containers sealed in such a manner as to prevent exposure to DBCP vapors or liquid, except for the requirements of paragraphs (i), (n) and (o) of this section. (b) Definitions. Authorized person means any person required by his duties to be present in regulated areas and authorized to do so by his employer, by this section, or by the Act. Authorized person also includes any person entering such areas as a designated representative of employees exercising an opportunity to observe employee exposure monitoring. DBCP means 1,2-dibromo-3-chloropropane, Chemical Abstracts Service Registry Number 96-12-8, and includes all for","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1044","vehicles":[]},{"i":21,"id":"cfr/1910.1045","section_id":"cfr/1910.1045","title":"29 CFR 1910.1045 Acrylonitrile","heading":"Acrylonitrile","text":"(a) Scope and application. (1) This section applies to all occupational exposures to acrylonitrile (AN), Chemical Abstracts Service Registry No. 000107131, except as provided in paragraphs (a)(2) and (a)(3) of this section. (2) This section does not apply to exposures which result solely from the processing, use, and handling of the following materials: (i) ABS resins, SAN resins, nitrile barrier resins, solid nitrile elastomers, and acrylic and modacrylic fibers, when these listed materials are in the form of finished polymers, and products fabricated from such finished polymers; (ii) Materials made from and/or containing AN for which objective data is reasonably relied upon to demonstrate that the material is not capable of releasing AN in airborne concentrations in excess of 1 ppm as an eight (8)-hour time-weighted average, under the expected conditions of processing, use, and handling which will cause the greatest possible release; ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1045","vehicles":[]},{"i":22,"id":"cfr/1910.1047","section_id":"cfr/1910.1047","title":"29 CFR 1910.1047 Ethylene oxide","heading":"Ethylene oxide","text":"(a) Scope and application. (1) This section applies to all occupational exposures to ethylene oxide (EtO), Chemical Abstracts Service Registry No. 75-21-8, except as provided in paragraph (a)(2) of this section. (2) This section does not apply to the processing, use, or handling of products containing EtO where objective data are reasonably relied upon that demonstrate that the product is not capable of releasing EtO in airborne concentrations at or above the action level, and may not reasonably be foreseen to release EtO in excess of the excursion limit, under the expected conditions of processing, use, or handling that will cause the greatest possible release. (3) Where products containing EtO are exempted under paragraph (a)(2) of this section, the employer shall maintain records of the objective data supporting that exemption and the basis for the employer's reliance on the data, as provided in paragraph (k)(1) of this section. (b) ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1047","vehicles":[]},{"i":23,"id":"cfr/1910.1048","section_id":"cfr/1910.1048","title":"29 CFR 1910.1048 Formaldehyde","heading":"Formaldehyde","text":"(a) Scope and application. This standard applies to all occupational exposures to formaldehyde, i.e. from formaldehyde gas, its solutions, and materials that release formaldehyde. (b) Definitions. For purposes of this standard, the following definitions shall apply: Action level means a concentration of 0.5 part formaldehyde per million parts of air (0.5 ppm) calculated as an eight (8)-hour time-weighted average (TWA) concentration. Assistant Secretary means the Assistant Secretary of Labor for the Occupational Safety and Health Administration, U.S. Department of Labor, or designee. Authorized person means any person required by work duties to be present in regulated areas, or authorized to do so by the employer, by this section, or by the OSH Act of 1970. Director means the Director of the National Institute for Occupational Safety and Health, U.S. Department of Health and Human Services, or designee. Emergency is any occurrence, such ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1048","vehicles":[]},{"i":24,"id":"cfr/1910.105","section_id":"cfr/1910.105","title":"29 CFR 1910.105 Nitrous oxide","heading":"Nitrous oxide","text":"The piped systems for the in-plant transfer and distribution of nitrous oxide shall be designed, installed, maintained, and operated in accordance with Compressed Gas Association Pamphlet G-8.1-1964, which is incorporated by reference as specified in \u00a7 1910.6. [39 FR 23502, June 27, 1974, as amended at 61 FR 9237, Mar. 7, 1996]","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.105","vehicles":[]},{"i":25,"id":"cfr/1910.1050","section_id":"cfr/1910.1050","title":"29 CFR 1910.1050 Methylenedianiline","heading":"Methylenedianiline","text":"(a) Scope and application. (1) This section applies to all occupational exposures to MDA, Chemical Abstracts Service Registry No. 101-77-9, except as provided in paragraphs (a)(2) through (a)(7) of this section. (2) Except as provided in paragraphs (a)(8) and (e)(5) of this section, this section does not apply to the processing, use, and handling of products containing MDA where initial monitoring indicates that the product is not capable of releasing MDA in excess of the action level under the expected conditions of processing, use, and handling which will cause the greatest possible release; and where no \u201cdermal exposure to MDA\u201d can occur. (3) Except as provided in paragraph (a)(8) of this section, this section does not apply to the processing, use, and handling of products containing MDA where objective data are reasonably relied upon which demonstrate the product is not capable of releasing MDA under the expected conditions of proce","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1050","vehicles":[]},{"i":26,"id":"cfr/1910.1051","section_id":"cfr/1910.1051","title":"29 CFR 1910.1051 1,3-Butadiene","heading":"1,3-Butadiene","text":"(a) Scope and application. (1) This section applies to all occupational exposures to 1,3-Butadiene (BD), Chemical Abstracts Service Registry No. 106-99-0, except as provided in paragraph (a)(2) of this section. (2)(i) Except for the recordkeeping provisions in paragraph (m)(1) of this section, this section does not apply to the processing, use, or handling of products containing BD or to other work operations and streams in which BD is present where objective data are reasonably relied upon that demonstrate the work operation or the product or the group of products or operations to which it belongs may not reasonably be foreseen to release BD in airborne concentrations at or above the action level or in excess of the STEL under the expected conditions of processing, use, or handling that will cause the greatest possible release or in any plausible accident. (ii) This section also does not apply to work operations, products or streams wh","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1051","vehicles":[]},{"i":27,"id":"cfr/1910.1052","section_id":"cfr/1910.1052","title":"29 CFR 1910.1052 Methylene chloride","heading":"Methylene chloride","text":"This occupational health standard establishes requirements for employers to control occupational exposure to methylene chloride (MC). Employees exposed to MC are at increased risk of developing cancer, adverse effects on the heart, central nervous system and liver, and skin or eye irritation. Exposure may occur through inhalation, by absorption through the skin, or through contact with the skin. MC is a solvent which is used in many different types of work activities, such as paint stripping, polyurethane foam manufacturing, and cleaning and degreasing. Under the requirements of paragraph (d) of this section, each covered employer must make an initial determination of each employee's exposure to MC. If the employer determines that employees are exposed below the action level, the only other provisions of this section that apply are that a record must be made of the determination, the employees must receive information and training under","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1052","vehicles":[]},{"i":28,"id":"cfr/1910.1053","section_id":"cfr/1910.1053","title":"29 CFR 1910.1053 Respirable crystalline silica","heading":"Respirable crystalline silica","text":"(a) Scope and application. (1) This section applies to all occupational exposures to respirable crystalline silica, except: (i) Construction work as defined in 29 CFR 1910.12(b) (occupational exposures to respirable crystalline silica in construction work are covered under 29 CFR 1926.1153); (ii) Agricultural operations covered under 29 CFR part 1928; and (iii) Exposures that result from the processing of sorptive clays. (2) This section does not apply where the employer has objective data demonstrating that employee exposure to respirable crystalline silica will remain below 25 micrograms per cubic meter of air (25 \u00b5g/m 3 ) as an 8-hour time-weighted average (TWA) under any foreseeable conditions. (3) This section does not apply if the employer complies with 29 CFR 1926.1153 and: (i) The task performed is indistinguishable from a construction task listed on Table 1 in paragraph (c) of 29 CFR 1926.1153; and (ii) The task will not be per","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1053","vehicles":[]},{"i":29,"id":"cfr/1910.106","section_id":"cfr/1910.106","title":"29 CFR 1910.106 Flammable liquids","heading":"Flammable liquids","text":"(a) Definitions. As used in this section: (1) Aerosol shall mean a material which is dispensed from its container as a mist, spray, or foam by a propellant under pressure. (2) Atmospheric tank shall mean a storage tank which has been designed to operate at pressures from atmospheric through 0.5 p.s.i.g. (3) Automotive service station shall mean that portion of property where flammable liquids used as motor fuels are stored and dispensed from fixed equipment into the fuel tanks of motor vehicles and shall include any facilities available for the sale and service of tires, batteries, and accessories, and for minor automotive maintenance work. Major automotive repairs, painting, body and fender work are excluded. (4) Basement shall mean a story of a building or structure having one-half or more of its height below ground level and to which access for fire fighting purposes is unduly restricted. (5) Boiling point shall mean the boiling poin","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.106","vehicles":[]},{"i":30,"id":"cfr/1910.107","section_id":"cfr/1910.107","title":"29 CFR 1910.107 Spray finishing using flammable and combustible materials","heading":"Spray finishing using flammable and combustible materials","text":"(a) Definitions applicable to this section \u2014(1) Aerated solid powders. Aerated powders shall mean any powdered material used as a coating material which shall be fluidized within a container by passing air uniformly from below. It is common practice to fluidize such materials to form a fluidized powder bed and then dip the part to be coated into the bed in a manner similar to that used in liquid dipping. Such beds are also used as sources for powder spray operations. (2) Spraying area. Any area in which dangerous quantities of flammable vapors or mists, or combustible residues, dusts, or deposits are present due to the operation of spraying processes. (3) Spray booth. A power-ventilated structure provided to enclose or accommodate a spraying operation to confine and limit the escape of spray, vapor, and residue, and to safely conduct or direct them to an exhaust system. (4) Waterwash spray booth. A spray booth equipped with a water wash","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.107","vehicles":[]},{"i":31,"id":"cfr/1910.109","section_id":"cfr/1910.109","title":"29 CFR 1910.109 Explosives and blasting agents","heading":"Explosives and blasting agents","text":"(a) Definitions applicable to this section \u2014(1) Blasting agent. Blasting agent\u2014any material or mixture, consisting of a fuel and oxidizer, intended for blasting, not otherwise classified as an explosive and in which none of the ingredients are classified as an explosive, provided that the finished product, as mixed and packaged for use or shipment, cannot be detonated by means of a No. 8 test blasting cap when unconfined. (2) Explosive-actuated power devices. Explosive-actuated power device\u2014any tool or special mechanized device which is actuated by explosives, but not including propellant-actuated power devices. Examples of explosive-actuated power devices are jet tappers and jet perforators. (3) Explosive. Explosive\u2014any chemical compound, mixture, or device, the primary or common purpose of which is to function by explosion, i.e., with substantially instantaneous release of gas and heat, unless such compound, mixture, or device is othe","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.109","vehicles":[]},{"i":32,"id":"cfr/1910.1096","section_id":"cfr/1910.1096","title":"29 CFR 1910.1096 Ionizing radiation","heading":"Ionizing radiation","text":"(a) Definitions applicable to this section \u2014(1) Radiation includes alpha rays, beta rays, gamma rays, X-rays, neutrons, high-speed electrons, high-speed protons, and other atomic particles; but such term does not include sound or radio waves, or visible light, or infrared or ultraviolet light. (2) Radioactive material means any material which emits, by spontaneous nuclear disintegration, corpuscular or electromagnetic emanations. (3) Restricted area means any area access to which is controlled by the employer for purposes of protection of individuals from exposure to radiation or radioactive materials. (4) Unrestricted area means any area access to which is not controlled by the employer for purposes of protection of individuals from exposure to radiation or radioactive materials. (5) Dose means the quantity of ionizing radiation absorbed, per unit of mass, by the body or by any portion of the body. When the provisions in this section s","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1096","vehicles":[]},{"i":33,"id":"cfr/1910.11","section_id":"cfr/1910.11","title":"29 CFR 1910.11 Scope and purpose","heading":"Scope and purpose","text":"(a) The provisions of this subpart B adopt and extend the applicability of, established Federal standards in effect on April 28, 1971, with respect to every employer, employee, and employment covered by the Act. (b) It bears emphasis that only standards (i.e., substantive rules) relating to safety or health are adopted by any incorporations by reference of standards prescribed elsewhere in this chapter or this title. Other materials contained in the referenced parties are not adopted. Illustrations of the types of materials which are not adopted are these. The incorporations by reference of parts 1915, 1916, 1917, 1918 in \u00a7\u00a7 1910.13, 1910.14, 1910.15, and 1910.16 are not intended to include the discussion in those parts of the coverage of the Longshoremen's and Harbor Workers' Compensation Act or the penalty provisions of the Act. Similarly, the incorporation by reference of part 1926 in \u00a7 1910.12 is not intended to include references t","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.11","vehicles":[]},{"i":34,"id":"cfr/1910.110","section_id":"cfr/1910.110","title":"29 CFR 1910.110 Storage and handling of liquefied petroleum gases","heading":"Storage and handling of liquefied petroleum gases","text":"(a) Definitions applicable to this section. As used in this section: (1) API-ASME container\u2014A container constructed in accordance with the requirements of paragraph (b)(3)(iii) of this section. (2) ASME container\u2014A container constructed in accordance with the requirements of paragraph (b)(3)(i) of this section. (3) Container assembly\u2014An assembly consisting essentially of the container and fittings for all container openings, including shutoff valves, excess flow valves, liquid-level gaging devices, safety relief devices, and protective housing. (4) Containers\u2014All vessels, such as tanks, cylinders, or drums, used for transportation or storing liquefied petroleum gases. (5) DOT\u2014Department of Transportation. (6) DOT container\u2014A container constructed in accordance with the applicable requirements of 49 CFR chapter 1. (7) \u201cLiquified petroleum gases\u201d\u2014\u201cLPG\u201d and \u201cLP-Gas\u201d\u2014Any material which is composed predominantly of any of the following hydro","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.110","vehicles":[]},{"i":35,"id":"cfr/1910.111","section_id":"cfr/1910.111","title":"29 CFR 1910.111 Storage and handling of anhydrous ammonia","heading":"Storage and handling of anhydrous ammonia","text":"(a) General \u2014(1) Scope. (i) This standard is intended to apply to the design, construction, location, installation, and operation of anhydrous ammonia systems including refrigerated ammonia storage systems. (ii) This standard does not apply to: ( a ) Ammonia manufacturing plants. ( b ) Refrigeration plants where ammonia is used solely as a refrigerant. (2) Definitions. As used in this section. (i) Appurtenances. All devices such as pumps, compressors, safety relief devices, liquid-level gaging devices, valves and pressure gages. (ii) Cylinder. A container of 1,000 pounds of water capacity or less constructed in accordance with Department of Transportation specifications. (iii) Code. The Boiler and Pressure Vessel Code, Section VIII, Unfired Pressure Vessels of the American Society of Mechanical Engineers (ASME)\u20141968. (iv) Container. Includes all vessels, tanks, cylinders, or spheres used for transportation, storage, or application of an","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.111","vehicles":[]},{"i":36,"id":"cfr/1910.119","section_id":"cfr/1910.119","title":"29 CFR 1910.119 Process safety management of highly hazardous chemicals","heading":"Process safety management of highly hazardous chemicals","text":"Purpose. This section contains requirements for preventing or minimizing the consequences of catastrophic releases of toxic, reactive, flammable, or explosive chemicals. These releases may result in toxic, fire or explosion hazards. (a) Application. (1) This section applies to the following: (i) A process which involves a chemical at or above the specified threshold quantities listed in appendix A to this section; (ii) A process which involves a Category 1 flammable gas (as defined in 1910.1200(c)) or a flammable liquid with a flashpoint below 100 \u00b0F (37.8 \u00b0C) on site in one location, in a quantity of 10,000 pounds (4535.9 kg) or more except for: (A) Hydrocarbon fuels used solely for workplace consumption as a fuel (e.g., propane used for comfort heating, gasoline for vehicle refueling), if such fuels are not a part of a process containing another highly hazardous chemical covered by this standard; (B) Flammable liquids with a flashpoin","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.119","vehicles":[]},{"i":37,"id":"cfr/1910.12","section_id":"cfr/1910.12","title":"29 CFR 1910.12 Construction work","heading":"Construction work","text":"(a) Standards. The standards prescribed in part 1926 of this chapter are adopted as occupational safety and health standards under section 6 of the Act and shall apply, according to the provisions thereof, to every employment and place of employment of every employee engaged in construction work. Each employer shall protect the employment and places of employment of each of his employees engaged in construction work by complying with the appropriate standards prescribed in this paragraph. (b) Definition. For purposes of this section, Construction work means work for construction, alteration, and/or repair, including painting and decorating. See discussion of these terms in \u00a7 1926.13 of this title. (c) Construction Safety Act distinguished. This section adopts as occupational safety and health standards under section 6 of the Act the standards which are prescribed in part 1926 of this chapter. Thus, the standards (substantive rules) publ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.12","vehicles":[]},{"i":38,"id":"cfr/1910.120","section_id":"cfr/1910.120","title":"29 CFR 1910.120 Hazardous waste operations and emergency response","heading":"Hazardous waste operations and emergency response","text":"(a) Scope, application, and definitions \u2014(1) Scope. This section covers the following operations, unless the employer can demonstrate that the operation does not involve employee exposure or the reasonable possibility for employee exposure to safety or health hazards: (i) Clean-up operations required by a governmental body, whether Federal, state, local or other involving hazardous substances that are conducted at uncontrolled hazardous waste sites (including, but not limited to, the EPA's National Priority Site List (NPL), state priority site lists, sites recommended for the EPA NPL, and initial investigations of government identified sites which are conducted before the presence or absence of hazardous substances has been ascertained); (ii) Corrective actions involving clean-up operations at sites covered by the Resource Conservation and Recovery Act of 1976 (RCRA) as amended (42 U.S.C. 6901 et seq. ); (iii) Voluntary clean-up operati","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.120","vehicles":[]},{"i":39,"id":"cfr/1910.1200","section_id":"cfr/1910.1200","title":"29 CFR 1910.1200 Hazard communication","heading":"Hazard communication","text":"(a) Purpose. (1) The purpose of this section is to ensure that the hazards of all chemicals produced or imported are classified, and that information concerning the classified hazards is transmitted to employers and employees. The requirements of this section are intended to be consistent with the provisions of the United Nations Globally Harmonized System of Classification and Labelling of Chemicals (GHS), Revision 3. The transmittal of information is to be accomplished by means of comprehensive hazard communication programs, which are to include container labeling and other forms of warning, safety data sheets and employee training. (2) This occupational safety and health standard is intended to address comprehensively the issue of classifying the potential hazards of chemicals, and communicating information concerning hazards and appropriate protective measures to employees, and to preempt any legislative or regulatory enactments of ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1200","vehicles":[]},{"i":40,"id":"cfr/1910.1201","section_id":"cfr/1910.1201","title":"29 CFR 1910.1201 Retention of DOT markings, placards and labels","heading":"Retention of DOT markings, placards and labels","text":"(a) Any employer who receives a package of hazardous material which is required to be marked, labeled or placarded in accordance with the U. S. Department of Transportation's Hazardous Materials Regulations (49 CFR Parts 171 through 180) shall retain those markings, labels and placards on the package until the packaging is sufficiently cleaned of residue and purged of vapors to remove any potential hazards. (b) Any employer who receives a freight container, rail freight car, motor vehicle, or transport vehicle that is required to be marked or placarded in accordance with the Hazardous Materials Regulations shall retain those markings and placards on the freight container, rail freight car, motor vehicle or transport vehicle until the hazardous materials which require the marking or placarding are sufficiently removed to prevent any potential hazards. (c) Markings, placards and labels shall be maintained in a manner that ensures that the","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1201","vehicles":[]},{"i":41,"id":"cfr/1910.122","section_id":"cfr/1910.122","title":"29 CFR 1910.122 Table of contents","heading":"Table of contents","text":"This section lists the paragraph headings contained in \u00a7\u00a7 1910.123 through 1910.126. \u00a7 1910.123 Dipping and coating operations: Coverage and definitions. (a) Does this rule apply to me? (b) What operations are covered? (c) What operations are not covered? (d) How are terms used in \u00a7\u00a7 1910.123 through 1910.126 defined? \u00a7 1910.124 General requirements for dipping and coating operations. (a) What construction requirements apply to dip tanks? (b) What ventilation requirements apply to vapor areas? (c) What requirements must I follow to recirculate exhaust air into the workplace? (d) What must I do when I use an exhaust hood? (e) What requirements must I follow when an employee enters a dip tank? (f) What first-aid procedures must my employees know? (g) What hygiene facilities must I provide? (h) What treatment and first aid must I provide? (i) What must I do before an employee cleans a dip tank? (j) What must I do to inspect and maintain my","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.122","vehicles":[]},{"i":42,"id":"cfr/1910.123","section_id":"cfr/1910.123","title":"29 CFR 1910.123 Dipping and coating operations: Coverage and definitions","heading":"Dipping and coating operations: Coverage and definitions","text":"(a) Does this rule apply to me? (1) This rule (\u00a7\u00a7 1910.123 through 1910.126) applies when you use a dip tank containing a liquid other than water. It applies when you use the liquid in the tank or its vapor to: (i) Clean an object; (ii) Coat an object; (iii) Alter the surface of an object; or (iv) Change the character of an object. (2) This rule also applies to the draining or drying of an object you have dipped or coated. (b) What operations are covered? Examples of covered operations are paint dipping, electroplating, pickling, quenching, tanning, degreasing, stripping, cleaning, roll coating, flow coating, and curtain coating. (c) What operations are not covered? You are not covered by this rule if your dip-tank operation only uses a molten material (a molten metal, alloy, or salt, for example). (d) How are terms used in \u00a7\u00a7 1910.123 through 1910.126 defined? Adjacent area means any area within 20 feet (6.1 m) of a vapor area that is ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.123","vehicles":[]},{"i":43,"id":"cfr/1910.124","section_id":"cfr/1910.124","title":"29 CFR 1910.124 General requirements for dipping and coating operations","heading":"General requirements for dipping and coating operations","text":"(a) What construction requirements apply to dip tanks? Any container that you use as a dip tank must be strong enough to withstand any expected load. (b) What ventilation requirements apply to vapor areas? (1) The ventilation that you provide to a vapor area must keep the airborne concentration of any substance below 25% of its LFL. (2) When a liquid in a dip tank creates an exposure hazard covered by a standard listed in subpart Z of this part, you must control worker exposure as required by that standard. (3) You may use a tank cover or material that floats on the surface of the liquid in a dip tank to replace or supplement ventilation. The method or combination of methods you choose must maintain the airborne concentration of the hazardous material and the worker's exposure within the limits specified in paragraphs (b)(1) and (b)(2) of this section. (4) When you use mechanical ventilation, it must conform to the following standards t","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.124","vehicles":[]},{"i":44,"id":"cfr/1910.125","section_id":"cfr/1910.125","title":"29 CFR 1910.125 Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 \u00b0F (93 \u00b0C)","heading":"Additional requirements for dipping and coating operations that use flammable liquids or liquids with flashpoints greater than 199.4 \u00b0F (93 \u00b0C)","text":"If you use flammable liquids, you must comply with the requirements of this section as well as the requirements of \u00a7\u00a7 1910.123, 1910.124, and 1910.126, as applicable. You must also comply with this section if: And: \u2022 The flashpoint of the liquid is 199.4 \u00b0F (93 \u00b0C) or above \u2022 The liquid is heated as part of the operation; or \u2022 A heated object is placed in the liquid. (a) What type of construction material must be used in making my dip tank? Your dip tank must be made of noncombustible material. (b) When must I provide overflow piping? (1) You must provide properly trapped overflow piping that discharges to a safe location for any dip tank having: (i) A capacity greater than 150 gallons (568 L); or (ii) A liquid surface area greater than 10 feet 2 (0.95 m 2 ). (2) You must also ensure that: (i) Any overflow piping is at least 3 inches (7.6 cm) in diameter and has sufficient capacity to prevent the dip tank from overflowing; (ii) Piping c","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.125","vehicles":[]},{"i":45,"id":"cfr/1910.126","section_id":"cfr/1910.126","title":"29 CFR 1910.126 Additional requirements for special dipping and coating operations","heading":"Additional requirements for special dipping and coating operations","text":"In addition to the requirements in \u00a7\u00a7 1910.123 through 1910.125, you must comply with any requirement in this section that applies to your operation. (a) What additional requirements apply to hardening or tempering tanks? (1) You must ensure that hardening or tempering tanks: (i) Are located as far as practicable from furnaces; (ii) Are on noncombustible flooring; and (iii) Have noncombustible hoods and vents (or equivalent devices) for venting to the outside. For this purpose, vent ducts must be treated as flues and kept away from combustible materials, particularly roofs. (2) You must equip each tank with an alarm that will sound if the temperature of the liquid comes within 50 \u00b0F (10 \u00b0C) of its flashpoint (the alarm set point). (3) When practicable, you must also provide each tank with a limit switch to shut down the conveyor supplying work to the tank. (4) If the temperature of the liquid can exceed the alarm set point, you must equ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.126","vehicles":[]},{"i":46,"id":"cfr/1910.132","section_id":"cfr/1910.132","title":"29 CFR 1910.132 General requirements","heading":"General requirements","text":"(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. (b) Employee-owned equipment. Where employees provide their own protective equipment, the employer shall be responsible to assure its adequacy, including proper maintenance, and sanitation of such equipment. (c) Design. All personal protective equipment shall be of safe design and construction for the work to be performed. (d) Hazard assessment and equipment selection. (1) The e","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.132","vehicles":[]},{"i":47,"id":"cfr/1910.133","section_id":"cfr/1910.133","title":"29 CFR 1910.133 Eye and face protection","heading":"Eye and face protection","text":"(a) General requirements. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. (2) The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable. (3) The employer shall ensure that each affected employee who wears prescription lenses while engaged in operations that involve eye hazards wears eye protection that incorporates the prescription in its design, or wears eye protection that can be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.133","vehicles":[]},{"i":48,"id":"cfr/1910.134","section_id":"cfr/1910.134","title":"29 CFR 1910.134 Respiratory protection","heading":"Respiratory protection","text":"This section applies to General Industry (part 1910), Shipyards (part 1915), Marine Terminals (part 1917), Longshoring (part 1918), and Construction (part 1926). (a) Permissible practice. (1) In the control of those occupational diseases caused by breathing air contaminated with harmful dusts, fogs, fumes, mists, gases, smokes, sprays, or vapors, the primary objective shall be to prevent atmospheric contamination. This shall be accomplished as far as feasible by accepted engineering control measures (for example, enclosure or confinement of the operation, general and local ventilation, and substitution of less toxic materials). When effective engineering controls are not feasible, or while they are being instituted, appropriate respirators shall be used pursuant to this section. (2) A respirator shall be provided to each employee when such equipment is necessary to protect the health of such employee. The employer shall provide the resp","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.134","vehicles":[]},{"i":49,"id":"cfr/1910.135","section_id":"cfr/1910.135","title":"29 CFR 1910.135 Head protection","heading":"Head protection","text":"(a) General requirements. (1) The employer shall ensure that each affected employee wears a protective helmet when working in areas where there is a potential for injury to the head from falling objects. (2) The employer shall ensure that a protective helmet designed to reduce electrical shock hazard is worn by each such affected employee when near exposed electrical conductors which could contact the head. (b) Criteria for head protection. (1) Head protection must comply with any of the following consensus standards: (i) American National Standards Institute (ANSI) Z89.1-2009, \u201cAmerican National Standard for Industrial Head Protection,\u201d incorporated by reference in \u00a7 1910.6; (ii) American National Standards Institute (ANSI) Z89.1-2003, \u201cAmerican National Standard for Industrial Head Protection,\u201d incorporated by reference in \u00a7 1910.6; or (iii) American National Standards Institute (ANSI) Z89.1-1997, \u201cAmerican National Standard for Perso","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.135","vehicles":[]},{"i":50,"id":"cfr/1910.136","section_id":"cfr/1910.136","title":"29 CFR 1910.136 Foot protection","heading":"Foot protection","text":"(a) General requirements. The employer shall ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, or when the use of protective footwear will protect the affected employee from an electrical hazard, such as a static-discharge or electric-shock hazard, that remains after the employer takes other necessary protective measures. (b) Criteria for protective footwear. (1) Protective footwear must comply with any of the following consensus standards: (i) ASTM F-2412-2005, \u201cStandard Test Methods for Foot Protection,\u201d and ASTM F-2413-2005, \u201cStandard Specification for Performance Requirements for Protective Footwear,\u201d which are incorporated by reference in \u00a7 1910.6; (ii) ANSI Z41-1999, \u201cAmerican National Standard for Personal Protection\u2014Protective Footwear,\u201d which is incorporated by reference in \u00a7 1910.6; or (iii)","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.136","vehicles":[]},{"i":51,"id":"cfr/1910.137","section_id":"cfr/1910.137","title":"29 CFR 1910.137 Electrical protective equipment","heading":"Electrical protective equipment","text":"(a) Design requirements for specific types of electrical protective equipment. Rubber insulating blankets, rubber insulating matting, rubber insulating covers, rubber insulating line hose, rubber insulating gloves, and rubber insulating sleeves shall meet the following requirements: (1) Manufacture and marking of rubber insulating equipment. (i) Blankets, gloves, and sleeves shall be produced by a seamless process. (ii) Each item shall be clearly marked as follows: (A) Class 00 equipment shall be marked Class 00. (B) Class 0 equipment shall be marked Class 0. (C) Class 1 equipment shall be marked Class 1. (D) Class 2 equipment shall be marked Class 2. (E) Class 3 equipment shall be marked Class 3. (F) Class 4 equipment shall be marked Class 4. (G) Nonozone-resistant equipment shall be marked Type I. (H) Ozone-resistant equipment shall be marked Type II. (I) Other relevant markings, such as the manufacturer's identification and the size ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.137","vehicles":[]},{"i":52,"id":"cfr/1910.138","section_id":"cfr/1910.138","title":"29 CFR 1910.138 Hand protection","heading":"Hand protection","text":"(a) General requirements. Employers shall select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes. (b) Selection. Employers shall base the selection of the appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) to be performed, conditions present, duration of use, and the hazards and potential hazards identified. [59 FR 16362, Apr. 6, 1994; 59 FR 33911, July 1, 1994]","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.138","vehicles":[]},{"i":53,"id":"cfr/1910.140","section_id":"cfr/1910.140","title":"29 CFR 1910.140 Personal fall protection systems","heading":"Personal fall protection systems","text":"(a) Scope and application. This section establishes performance, care, and use criteria for all personal fall protection systems. The employer must ensure that each personal fall protection system used to comply with this part must meet the requirements of this section. (b) Definitions. The following definitions apply to this section: Anchorage means a secure point of attachment for equipment such as lifelines, lanyards, or deceleration devices. Belt terminal means an end attachment of a window cleaner's positioning system used for securing the belt or harness to a window cleaner's belt anchor. Body belt means a strap with means both for securing about the waist and for attaching to other components such as a lanyard used with positioning systems, travel restraint systems, or ladder safety systems. Body harness means straps that secure about the employee in a manner to distribute the fall arrest forces over at least the thighs, pelvis, ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.140","vehicles":[]},{"i":54,"id":"cfr/1910.141","section_id":"cfr/1910.141","title":"29 CFR 1910.141 Sanitation","heading":"Sanitation","text":"(a) General \u2014(1) Scope. This section applies to permanent places of employment. (2) Definitions applicable to this section. Nonwater carriage toilet facility, means a toilet facility not connected to a sewer. Number of employees means, unless otherwise specified, the maximum number of employees present at any one time on a regular shift. Personal service room, means a room used for activities not directly connected with the production or service function performed by the establishment. Such activities include, but are not limited to, first-aid, medical services, dressing, showering, toilet use, washing, and eating. Potable water means water that meets the standards for drinking purposes of the State or local authority having jurisdiction, or water that meets the quality standards prescribed by the U.S. Environmental Protection Agency's National Primary Drinking Water Regulations (40 CFR 141). Toilet facility, means a fixture maintained ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.141","vehicles":[]},{"i":55,"id":"cfr/1910.142","section_id":"cfr/1910.142","title":"29 CFR 1910.142 Temporary labor camps","heading":"Temporary labor camps","text":"(a) Site. (1) All sites used for camps shall be adequately drained. They shall not be subject to periodic flooding, nor located within 200 feet of swamps, pools, sink holes, or other surface collections of water unless such quiescent water surfaces can be subjected to mosquito control measures. The camp shall be located so the drainage from and through the camp will not endanger any domestic or public water supply. All sites shall be graded, ditched, and rendered free from depressions in which water may become a nuisance. (2) All sites shall be adequate in size to prevent overcrowding of necessary structures. The principal camp area in which food is prepared and served and where sleeping quarters are located shall be at least 500 feet from any area in which livestock is kept. (3) The grounds and open areas surrounding the shelters shall be maintained in a clean and sanitary condition free from rubbish, debris, waste paper, garbage, or o","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.142","vehicles":[]},{"i":56,"id":"cfr/1910.144","section_id":"cfr/1910.144","title":"29 CFR 1910.144 Safety color code for marking physical hazards","heading":"Safety color code for marking physical hazards","text":"(a) Color identification \u2014(1) Red. Red shall be the basic color for the identification of: (i) Fire protection equipment and apparatus. [Reserved] (ii) Danger. Safety cans or other portable containers of flammable liquids having a flash point at or below 80 \u00b0F, table containers of flammable liquids (open cup tester), excluding shipping containers, shall be painted red with some additional clearly visible identification either in the form of a yellow band around the can or the name of the contents conspicuously stenciled or painted on the can in yellow. Red lights shall be provided at barricades and at temporary obstructions. Danger signs shall be painted red. (iii) Stop. Emergency stop bars on hazardous machines such as rubber mills, wire blocks, flat work ironers, etc., shall be red. Stop buttons or electrical switches which letters or other markings appear, used for emergency stopping of machinery shall be red. (2) [Reserved] (3) Yell","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.144","vehicles":[]},{"i":57,"id":"cfr/1910.145","section_id":"cfr/1910.145","title":"29 CFR 1910.145 Specifications for accident prevention signs and tags","heading":"Specifications for accident prevention signs and tags","text":"(a) Scope. (1) These specifications apply to the design, application, and use of signs or symbols (as included in paragraphs (c) through (e) of this section) intended to indicate and, insofar as possible, to define specific hazards of a nature such that failure to designate them may lead to accidental injury to workers or the public, or both, or to property damage. These specifications are intended to cover all safety signs except those designed for streets, highways, and railroads. These specifications do not apply to plant bulletin boards or to safety posters. (2) All new signs and replacements of old signs shall be in accordance with these specifications. (b) Definitions. As used in this section, the word sign refers to a surface on prepared for the warning of, or safety instructions of, industrial workers or members of the public who may be exposed to hazards. Excluded from this definition, however, are news releases, displays commo","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.145","vehicles":[]},{"i":58,"id":"cfr/1910.1450","section_id":"cfr/1910.1450","title":"29 CFR 1910.1450 Occupational exposure to hazardous chemicals in laboratories","heading":"Occupational exposure to hazardous chemicals in laboratories","text":"(a) Scope and application. (1) This section shall apply to all employers engaged in the laboratory use of hazardous chemicals as defined below. (2) Where this section applies, it shall supersede, for laboratories, the requirements of all other OSHA health standards in 29 CFR part 1910, subpart Z, except as follows: (i) For any OSHA health standard, only the requirement to limit employee exposure to the specific permissible exposure limit shall apply for laboratories, unless that particular standard states otherwise or unless the conditions of paragraph (a)(2)(iii) of this section apply. (ii) Prohibition of eye and skin contact where specified by any OSHA health standard shall be observed. (iii) Where the action level (or in the absence of an action level, the permissible exposure limit) is routinely exceeded for an OSHA regulated substance with exposure monitoring and medical surveillance requirements, paragraphs (d) and (g)(1)(ii) of t","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1450","vehicles":[]},{"i":59,"id":"cfr/1910.146","section_id":"cfr/1910.146","title":"29 CFR 1910.146 Permit-required confined spaces","heading":"Permit-required confined spaces","text":"(a) Scope and application. This section contains requirements for practices and procedures to protect employees in general industry from the hazards of entry into permit-required confined spaces. This section does not apply to agriculture, to construction, or to shipyard employment (parts 1928, 1926, and 1915 of this chapter, respectively). (b) Definitions. Acceptable entry conditions means the conditions that must exist in a permit space to allow entry and to ensure that employees involved with a permit-required confined space entry can safely enter into and work within the space. Attendant means an individual stationed outside one or more permit spaces who monitors the authorized entrants and who performs all attendant's duties assigned in the employer's permit space program. Authorized entrant means an employee who is authorized by the employer to enter a permit space. Blanking or blinding means the absolute closure of a pipe, line, ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.146","vehicles":[]},{"i":60,"id":"cfr/1910.147","section_id":"cfr/1910.147","title":"29 CFR 1910.147 The control of hazardous energy (lockout/tagout)","heading":"The control of hazardous energy (lockout/tagout)","text":"(a) Scope, application, and purpose \u2014(1) Scope. (i) This standard covers the servicing and maintenance of machines and equipment in which the unexpected energization or start up of the machines or equipment, or release of stored energy could cause injury to employees. This standard establishes minimum performance requirements for the control of such hazardous energy. (ii) This standard does not cover the following: (A) Construction and agriculture employment; (B) Employment covered by parts 1915, 1917, and 1918 of this title; (C) Installations under the exclusive control of electric utilities for the purpose of power generation, transmission and distribution, including related equipment for communication or metering; (D) Exposure to electrical hazards from work on, near, or with conductors or equipment in electric-utilization installations, which is covered by subpart S of this part; and (E) Oil and gas well drilling and servicing. (2) ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147","vehicles":[]},{"i":61,"id":"cfr/1910.15","section_id":"cfr/1910.15","title":"29 CFR 1910.15 Shipyard employment","heading":"Shipyard employment","text":"(a) Adoption and extension of established safety and health standards for shipyard employment. The standards prescribed by part 1915 (formerly parts 1501-1503) of this title and in effect on April 28, 1971 (as revised), are adopted as occupational safety or health standards under section 6(a) of the Act and shall apply, according to the provisions thereof, to every employment and place of employment of every employee engaged in ship repair, shipbreaking, and shipbuilding, or a related employment. Each employer shall protect the employment and places of employment of each of his employees engaged in ship repair, shipbreaking, and shipbuilding, or a related employment, by complying with the appropriate standards prescribed by this paragraph. (b) Definitions. For purposes of this section: (1) Ship repair means any repair of a vessel, including, but not restricted to, alterations, conversions, installations, cleaning, painting, and maintena","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.15","vehicles":[]},{"i":62,"id":"cfr/1910.151","section_id":"cfr/1910.151","title":"29 CFR 1910.151 Medical services and first aid","heading":"Medical services and first aid","text":"(a) The employer shall ensure the ready availability of medical personnel for advice and consultation on matters of plant health. (b) In the absence of an infirmary, clinic, or hospital in near proximity to the workplace which is used for the treatment of all injured employees, a person or persons shall be adequately trained to render first aid. Adequate first aid supplies shall be readily available. (c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. Appendix A to \u00a7 1910.151\u2014First aid kits (Non-Mandatory) First aid supplies are required to be readily available under paragraph \u00a7 1910.151(b). An example of the minimal contents of a generic first aid kit is described in American National Standard (ANSI) Z308.1-1998 \u201cMinimum Requirements for Workplace First-aid Ki","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.151","vehicles":[]},{"i":63,"id":"cfr/1910.155","section_id":"cfr/1910.155","title":"29 CFR 1910.155 Scope, application and definitions applicable to this subpart","heading":"Scope, application and definitions applicable to this subpart","text":"(a) Scope. This subpart contains requirements for fire brigades, and all portable and fixed fire suppression equipment, fire detection systems, and fire or employee alarm systems installed to meet the fire protection requirements of 29 CFR part 1910. (b) Application. This subpart applies to all employments except for maritime, construction, and agriculture. (c) Definitions applicable to this subpart \u2014(1) After-flame means the time a test specimen continues to flame after the flame source has been removed. (2) Aqueous film forming foam (AFFF) means a fluorinated surfactant with a foam stabilizer which is diluted with water to act as a temporary barrier to exclude air from mixing with the fuel vapor by developing an aqueous film on the fuel surface of some hydrocarbons which is capable of suppressing the generation of fuel vapors. (3) Approved means acceptable to the Assistant Secretary under the following criteria: (i) If it is accepted,","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.155","vehicles":[]},{"i":64,"id":"cfr/1910.156","section_id":"cfr/1910.156","title":"29 CFR 1910.156 Fire brigades","heading":"Fire brigades","text":"(a) Scope and application \u2014(1) Scope. This section contains requirements for the organization, training, and personal protective equipment of fire brigades whenever they are established by an employer. (2) Application. The requirements of this section apply to fire brigades, industrial fire departments and private or contractual type fire departments. Personal protective equipment requirements apply only to members of fire brigades performing interior structural fire fighting. The requirements of this section do not apply to airport crash rescue or forest fire fighting operations. (b) Organization \u2014(1) Organizational statement. The employer shall prepare and maintain a statement or written policy which establishes the existence of a fire brigade; the basic organizational structure; the type, amount, and frequency of training to be provided to fire brigade members; the expected number of members in the fire brigade; and the functions tha","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.156","vehicles":[]},{"i":65,"id":"cfr/1910.157","section_id":"cfr/1910.157","title":"29 CFR 1910.157 Portable fire extinguishers","heading":"Portable fire extinguishers","text":"(a) Scope and application. The requirements of this section apply to the placement, use, maintenance, and testing of portable fire extinguishers provided for the use of employees. Paragraph (d) of this section does not apply to extinguishers provided for employee use on the outside of workplace buildings or structures. Where extinguishers are provided but are not intended for employee use and the employer has an emergency action plan and a fire prevention plan that meet the requirements of 29 CFR 1910.38 and 29 CFR 1910.39 respectively, then only the requirements of paragraphs (e) and (f) of this section apply. (b) Exemptions. (1) Where the employer has established and implemented a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal and which includes an emergency action plan and a fire prevention plan which meet the requirements of 29 CFR","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.157","vehicles":[]},{"i":66,"id":"cfr/1910.158","section_id":"cfr/1910.158","title":"29 CFR 1910.158 Standpipe and hose systems","heading":"Standpipe and hose systems","text":"(a) Scope and application \u2014(1) Scope. This section applies to all small hose, Class II, and Class III standpipe systems installed to meet the requirements of a particular OSHA standard. (2) Exception. This section does not apply to Class I standpipe systems. (b) Protection of standpipes. The employer shall assure that standpipes are located or otherwise protected against mechanical damage. Damaged standpipes shall be repaired promptly. (c) Equipment \u2014(1) Reels and cabinets. Where reels or cabinets are provided to contain fire hose, the employer shall assure that they are designed to facilitate prompt use of the hose valves, the hose, and other equipment at the time of a fire or other emergency. The employer shall assure that the reels and cabinets are conspicuously identified and used only for fire equipment. (2) Hose outlets and connections. (i) The employer shall assure that hose outlets and connections are located high enough above t","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.158","vehicles":[]},{"i":67,"id":"cfr/1910.159","section_id":"cfr/1910.159","title":"29 CFR 1910.159 Automatic sprinkler systems","heading":"Automatic sprinkler systems","text":"(a) Scope and application. (1) The requirements of this section apply to all automatic sprinkler systems installed to meet a particular OSHA standard. (2) For automatic sprinkler systems used to meet OSHA requirements and installed prior to the effective date of this standard, compliance with the National Fire Protection Association (NFPA) or the National Board of Fire Underwriters (NBFU) standard in effect at the time of the system's installation will be acceptable as compliance with this section. (b) Exemptions. Automatic sprinkler systems installed in workplaces, but not required by OSHA, are exempt from the requirements of this section. (c) General requirements \u2014(1) Design. (i) All automatic sprinkler designs used to comply with this standard shall provide the necessary discharge patterns, densities, and water flow characteristics for complete coverage in a particular workplace or zoned subdivision of the workplace. (ii) The employe","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.159","vehicles":[]},{"i":68,"id":"cfr/1910.16","section_id":"cfr/1910.16","title":"29 CFR 1910.16 Longshoring and marine terminals","heading":"Longshoring and marine terminals","text":"(a) Safety and health standards for longshoring. (1) Part 1918 of this chapter shall apply exclusively, according to the provisions thereof, to all employment of every employee engaged in longshoring operations or related employment aboard any vessel. All cargo transfer accomplished with the use of shore-based material handling devices shall be governed by part 1917 of this chapter. (2) Part 1910 does not apply to longshoring operations except for the following provisions: (i) Access to employee exposure and medical records. Subpart Z, \u00a7 1910.1020; (ii) Commercial diving operations. Subpart T; (iii) Electrical. Subpart S when shore-based electrical installations provide power for use aboard vessels; (iv) Hazard communication. Subpart Z, \u00a7 1910.1200; (v) Ionizing radiation. Subpart Z, \u00a7 1910.1096; (vi) Noise. Subpart G, \u00a7 1910.95; (vii) Nonionizing radiation. Subpart G, \u00a7 1910.97; Note to paragraph ( a )(2)( vii ): Exposures to nonionizi","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.16","vehicles":[]},{"i":69,"id":"cfr/1910.160","section_id":"cfr/1910.160","title":"29 CFR 1910.160 Fixed extinguishing systems, general","heading":"Fixed extinguishing systems, general","text":"(a) Scope and application. (1) This section applies to all fixed extinguishing systems installed to meet a particular OSHA standard except for automatic sprinkler systems which are covered by \u00a7 1910.159. (2) This section also applies to fixed systems not installed to meet a particular OSHA standard, but which, by means of their operation, may expose employees to possible injury, death, or adverse health consequences caused by the extinguishing agent. Such systems are only subject to the requirements of paragraphs (b)(4) through (b)(7) and (c) of this section. (3) Systems otherwise covered in paragraph (a)(2) of this section which are installed in areas with no employee exposure are exempted from the requirements of this section. (b) General requirements. (1) Fixed extinguishing system components and agents shall be designed and approved for use on the specific fire hazards they are expected to control or extinguish. (2) If for any reaso","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.160","vehicles":[]},{"i":70,"id":"cfr/1910.161","section_id":"cfr/1910.161","title":"29 CFR 1910.161 Fixed extinguishing systems, dry chemical","heading":"Fixed extinguishing systems, dry chemical","text":"(a) Scope and application. This section applies to all fixed extinguishing systems, using dry chemical as the extinguishing agent, installed to meet a particular OSHA standard. These systems shall also comply with \u00a7 1910.160. (b) Specific requirements. (1) The employer shall assure that dry chemical agents are compatible with any foams or wetting agents with which they are used. (2) The employer may not mix together dry chemical extinguishing agents of different compositions. The employer shall assure that dry chemical systems are refilled with the chemical stated on the approval nameplate or an equivalent compatible material. (3) When dry chemical discharge may obscure vision, the employer shall provide a pre-discharge employee alarm which complies with \u00a7 1910.165 and which will give employees time to safely exit from the discharge area prior to system discharge. (4) The employer shall sample the dry chemical supply of all but stored p","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.161","vehicles":[]},{"i":71,"id":"cfr/1910.162","section_id":"cfr/1910.162","title":"29 CFR 1910.162 Fixed extinguishing systems, gaseous agent","heading":"Fixed extinguishing systems, gaseous agent","text":"(a) Scope and application \u2014(1) Scope. This section applies to all fixed extinguishing systems, using a gas as the extinguishing agent, installed to meet a particular OSHA standard. These systems shall also comply with \u00a7 1910.160. In some cases, the gas may be in a liquid state during storage. (2) Application. The requirements of paragraphs (b)(2) and (b)(4) through (b)(6) shall apply only to total flooding systems. (b) Specific requirements. (1) Agents used for initial supply and replenishment shall be of the type approved for the system's application. Carbon dioxide obtained by dry ice conversion to liquid is not acceptable unless it is processed to remove excess water and oil. (2) Except during overhaul, the employer shall assure that the designed concentration of gaseous agents is maintained until the fire has been extinguished or is under control. (3) The employer shall assure that employees are not exposed to toxic levels of gaseou","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.162","vehicles":[]},{"i":72,"id":"cfr/1910.163","section_id":"cfr/1910.163","title":"29 CFR 1910.163 Fixed extinguishing systems, water spray and foam","heading":"Fixed extinguishing systems, water spray and foam","text":"(a) Scope and application. This section applies to all fixed extinguishing systems, using water or foam solution as the extinguishing agent, installed to meet a particular OSHA standard. These systems shall also comply with \u00a7 1910.160. This section does not apply to automatic sprinkler systems which are covered under \u00a7 1910.159. (b) Specific requirements. (1) The employer shall assure that foam and water spray systems are designed to be effective in at least controlling fire in the protected area or on protected equipment. (2) The employer shall assure that drainage of water spray systems is directed away from areas where employees are working and that no emergency egress is permitted through the drainage path. [45 FR 60712, Sept. 12, 1980]","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.163","vehicles":[]},{"i":73,"id":"cfr/1910.164","section_id":"cfr/1910.164","title":"29 CFR 1910.164 Fire detection systems","heading":"Fire detection systems","text":"(a) Scope and application. This section applies to all automatic fire detection systems installed to meet the requirements of a particular OSHA standard. (b) Installation and restoration. (1) The employer shall assure that all devices and equipment constructed and installed to comply with this standard are approved for the purpose for which they are intended. (2) The employer shall restore all fire detection systems and components to normal operating condition as promptly as possible after each test or alarm. Spare detection devices and components which are normally destroyed in the process of detecting fires shall be available on the premises or from a local supplier in sufficient quantities and locations for prompt restoration of the system. (c) Maintenance and testing. (1) The employer shall maintain all systems in an operable condition except during repairs or maintenance. (2) The employer shall assure that fire detectors and fire d","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.164","vehicles":[]},{"i":74,"id":"cfr/1910.165","section_id":"cfr/1910.165","title":"29 CFR 1910.165 Employee alarm systems","heading":"Employee alarm systems","text":"(a) Scope and application. (1) This section applies to all emergency employee alarms installed to meet a particular OSHA standard. This section does not apply to those discharge or supervisory alarms required on various fixed extinguishing systems or to supervisory alarms on fire suppression, alarm or detection systems unless they are intended to be employee alarm systems. (2) The requirements in this section that pertain to maintenance, testing and inspection shall apply to all local fire alarm signaling systems used for alerting employees regardless of the other functions of the system. (3) All pre-discharge employee alarms installed to meet a particular OSHA standard shall meet the requirements of paragraphs (b)(1) through (4), (c), and (d)(1) of this section. (b) General requirements. (1) The employee alarm system shall provide warning for necessary emergency action as called for in the emergency action plan, or for reaction time fo","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.165","vehicles":[]},{"i":75,"id":"cfr/1910.169","section_id":"cfr/1910.169","title":"29 CFR 1910.169 Air receivers","heading":"Air receivers","text":"(a) General requirements \u2014(1) Application. This section applies to compressed air receivers, and other equipment used in providing and utilizing compressed air for performing operations such as cleaning, drilling, hoisting, and chipping. On the other hand, however, this section does not deal with the special problems created by using compressed air to convey materials nor the problems created when men work in compressed air as in tunnels and caissons. This section is not intended to apply to compressed air machinery and equipment used on transportation vehicles such as steam railroad cars, electric railway cars, and automotive equipment. (2) New and existing equipment. (i) All new air receivers installed after the effective date of these regulations shall be constructed in accordance with the 1968 edition of the A.S.M.E. Boiler and Pressure Vessel Code Section VIII, which is incorporated by reference as specified in \u00a7 1910.6. (ii) All s","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.169","vehicles":[]},{"i":76,"id":"cfr/1910.17","section_id":"cfr/1910.17","title":"29 CFR 1910.17 Effective dates","heading":"Effective dates","text":"(a)-(b) [Reserved] (c) Except whenever any employment or place of employment is, or becomes, subject to any safety and health standard prescribed in part 1915, 1916, 1917, 1918, or 1926 of this title on a date before August 27, 1971, by virtue of the Construction Safety Act or the Longshoremen's and Harbor Workers' Compensation Act, that occupational safety and health standard as incorporated by reference in this subpart shall also become effective under the Williams-Steiger Occupational Safety and Health Act of 1970 on that date. [39 FR 23502, June 27, 1974, as amended at 61 FR 9235, Mar. 7, 1996]","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.17","vehicles":[]},{"i":77,"id":"cfr/1910.176","section_id":"cfr/1910.176","title":"29 CFR 1910.176 Handling materials\u2014general","heading":"Handling materials\u2014general","text":"(a) Use of mechanical equipment. Where mechanical handling equipment is used, sufficient safe clearances shall be allowed for aisles, at loading docks, through doorways and wherever turns or passage must be made. Aisles and passageways shall be kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. Permanent aisles and passageways shall be appropriately marked. (b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse. (c) Housekeeping. Storage areas shall be kept free from accumulation of materials that constitute hazards from tripping, fire, explosion, or pest harborage. Vegetation control will be exercised when necessary. (d) [Reserved] (e) Clearance limits. Clearance signs to warn of clearance limits shall be p","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.176","vehicles":[]},{"i":78,"id":"cfr/1910.177","section_id":"cfr/1910.177","title":"29 CFR 1910.177 Servicing multi-piece and single piece rim wheels","heading":"Servicing multi-piece and single piece rim wheels","text":"(a) Scope. (1) This section applies to the servicing of multi-piece and single piece rim wheels used on large vehicles such as trucks, tractors, trailers, buses and off-road machines. It does not apply to the servicing of rim wheels used on automobiles, or on pickup trucks and vans utilizing automobile tires or truck tires designated \u201cLT\u201d. (2) This section does not apply to employers and places of employment regulated under the Longshoring Standards, 29 CFR part 1918; Construction Safety Standards, 29 CFR part 1926; or Agriculture Standards, 29 CFR part 1928. (3) All provisions of this section apply to the servicing of both single piece rim wheels and multi-piece rim wheels unless designated otherwise. (b) Definitions. Barrier means a fence, wall or other structure or object placed between a single piece rim wheel and an employee during tire inflation, to contain the rim wheel components in the event of the sudden release of the contain","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.177","vehicles":[]},{"i":79,"id":"cfr/1910.178","section_id":"cfr/1910.178","title":"29 CFR 1910.178 Powered industrial trucks","heading":"Powered industrial trucks","text":"(a) General requirements. (1) This section contains safety requirements relating to fire protection, design, maintenance, and use of fork trucks, tractors, platform lift trucks, motorized hand trucks, and other specialized industrial trucks powered by electric motors or internal combustion engines. This section does not apply to compressed air or nonflammable compressed gas-operated industrial trucks, nor to farm vehicles, nor to vehicles intended primarily for earth moving or over-the-road hauling. (2) All new powered industrial trucks acquired and used by an employer shall meet the design and construction requirements for powered industrial trucks established in the \u201cAmerican National Standard for Powered Industrial Trucks, Part II, ANSI B56.1-1969\u201d, which is incorporated by reference as specified in \u00a7 1910.6, except for vehicles intended primarily for earth moving or over-the-road hauling. (3) Approved trucks shall bear a label or so","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.178","vehicles":[]},{"i":80,"id":"cfr/1910.179","section_id":"cfr/1910.179","title":"29 CFR 1910.179 Overhead and gantry cranes","heading":"Overhead and gantry cranes","text":"(a) Definitions applicable to this section. (1) A crane is a machine for lifting and lowering a load and moving it horizontally, with the hoisting mechanism an integral part of the machine. Cranes whether fixed or mobile are driven manually or by power. (2) An automatic crane is a crane which when activated operates through a preset cycle or cycles. (3) A cab-operated crane is a crane controlled by an operator in a cab located on the bridge or trolley. (4) Cantilever gantry crane means a gantry or semigantry crane in which the bridge girders or trusses extend transversely beyond the crane runway on one or both sides. (5) Floor-operated crane means a crane which is pendant or nonconductive rope controlled by an operator on the floor or an independent platform. (6) Gantry crane means a crane similar to an overhead crane except that the bridge for carrying the trolley or trolleys is rigidly supported on two or more legs running on fixed ra","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.179","vehicles":[]},{"i":81,"id":"cfr/1910.18","section_id":"cfr/1910.18","title":"29 CFR 1910.18 Changes in established Federal standards","heading":"Changes in established Federal standards","text":"Whenever an occupational safety and health standard adopted and incorporated by reference in this subpart B is changed pursuant to section 6(b) of the Act and the statute under which the standard was originally promulgated, and in accordance with part 1911 of this chapter, the standard shall be deemed changed for purposes of that statute and this subpart B, and shall apply under this subpart B. For the purposes of this section, a change in a standard includes any amendment, addition, or repeal, in whole or in part, of any standard.","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.18","vehicles":[]},{"i":82,"id":"cfr/1910.180","section_id":"cfr/1910.180","title":"29 CFR 1910.180 Crawler locomotive and truck cranes","heading":"Crawler locomotive and truck cranes","text":"(a) Definitions applicable to this section. (1) A crawler crane consists of a rotating superstructure with power plant, operating machinery, and boom, mounted on a base, equipped with crawler treads for travel. Its function is to hoist and swing loads at various radii. (2) A locomotive crane consists of a rotating superstructure with power-plant, operating machinery and boom, mounted on a base or car equipped for travel on railroad track. It may be self-propelled or propelled by an outside source. Its function is to hoist and swing loads at various radii. (3) A truck crane consists of a rotating superstructure with powerplant, operating machinery and boom, mounted on an automotive truck equipped with a powerplant for travel. Its function is to hoist and swing loads at various radii. (4) A wheel mounted crane (wagon crane) consists of a rotating superstructure with powerplant, operating machinery and boom, mounted on a base or platform e","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.180","vehicles":[]},{"i":83,"id":"cfr/1910.181","section_id":"cfr/1910.181","title":"29 CFR 1910.181 Derricks","heading":"Derricks","text":"(a) Definitions applicable to this section. (1) A derrick is an apparatus consisting of a mast or equivalent member held at the head by guys or braces, with or without a boom, for use with a hoisting mechanism and operating ropes. (2) A-frame derrick means a derrick in which the boom is hinged from a cross member between the bottom ends of two upright members spread apart at the lower ends and joined at the top; the boom point secured to the junction of the side members, and the side members are braced or guyed from this junction point. EC27OC91.037 (3) A basket derrick is a derrick without a boom, similar to a gin pole, with its base supported by ropes attached to corner posts or other parts of the structure. The base is at a lower elevation than its supports. The location of the base of a basket derrick can be changed by varying the length of the rope supports. The top of the pole is secured with multiple reeved guys to position the t","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.181","vehicles":[]},{"i":84,"id":"cfr/1910.183","section_id":"cfr/1910.183","title":"29 CFR 1910.183 Helicopters","heading":"Helicopters","text":"(a) [Reserved] (b) Briefing. Prior to each day's operation a briefing shall be conducted. This briefing shall set forth the plan of operation for the pilot and ground personnel. (c) Slings and tag lines. Loads shall be properly slung. Tag lines shall be of a length that will not permit their being drawn up into the rotors. Pressed sleeve, swedged eyes, or equivalent means shall be used for all freely suspended loads to prevent hand splices from spinning open or cable clamps from loosening. (d) Cargo hooks. All electrically operated cargo hooks shall have the electrical activating device so designed and installed as to prevent inadvertent operation. In addition, these cargo hooks shall be equipped with an emergency mechanical control for releasing the load. The employer shall ensure that the hooks are tested prior to each day's operation by a competent person to determine that the release functions properly, both electrically and mechani","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.183","vehicles":[]},{"i":85,"id":"cfr/1910.184","section_id":"cfr/1910.184","title":"29 CFR 1910.184 Slings","heading":"Slings","text":"(a) Scope. This section applies to slings used in conjunction with other material handling equipment for the movement of material by hoisting, in employments covered by this part. The types of slings covered are those made from alloy steel chain, wire rope, metal mesh, natural or synthetic fiber rope (conventional three strand construction), and synthetic web (nylon, polyester, and polypropylene). (b) Definitions. Angle of loading is the inclination of a leg or branch of a sling measured from the horizontal or vertical plane as shown in Fig. N-184-5; provided that an angle of loading of five degrees or less from the vertical may be considered a vertical angle of loading. Basket hitch is a sling configuration whereby the sling is passed under the load and has both ends, end attachments, eyes or handles on the hook or a single master link. Braided wire rope is a wire rope formed by plaiting component wire ropes. Bridle wire rope sling is ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.184","vehicles":[]},{"i":86,"id":"cfr/1910.19","section_id":"cfr/1910.19","title":"29 CFR 1910.19 Special provisions for air contaminants","heading":"Special provisions for air contaminants","text":"(a) Asbestos, tremolite, anthophyllite, and actinolite dust. Section 1910.1001 shall apply to the exposure of every employee to asbestos, tremolite, anthophyllite, and actinolite dust in every employment and place of employment covered by \u00a7 1910.16, in lieu of any different standard on exposure to asbestos, tremolite, anthophyllite, and actinolite dust which would otherwise be applicable by virtue of any of those sections. (b) Vinyl chloride. Section 1910.1017 shall apply to the exposure of every employee to vinyl chloride in every employment and place of employment covered by \u00a7 1910.12, \u00a7 1910.13, \u00a7 1910.14, \u00a7 1910.15, or \u00a7 1910.16, in lieu of any different standard on exposure to vinyl chloride which would otherwise be applicable by virtue of any of those sections. (c) Acrylonitrile. Section 1910.1045 shall apply to the exposure of every employee to acrylonitrile in every employment and place of employment covered by \u00a7 1910.12, \u00a7 1910","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.19","vehicles":[]},{"i":87,"id":"cfr/1910.21","section_id":"cfr/1910.21","title":"29 CFR 1910.21 Scope and definitions","heading":"Scope and definitions","text":"(a) Scope. This subpart applies to all general industry workplaces. It covers all walking-working surfaces unless specifically excluded by an individual section of this subpart. (b) Definitions. The following definitions apply in this subpart: Alternating tread-type stair means a type of stairway consisting of a series of treads that usually are attached to a center support in an alternating manner such that an employee typically does not have both feet on the same level while using the stairway. Anchorage means a secure point of attachment for equipment such as lifelines, lanyards, deceleration devices, and rope descent systems. Authorized means an employee who the employer assigns to perform a specific type of duty, or allows in a specific location or area. Cage means an enclosure mounted on the side rails of a fixed ladder or fastened to a structure behind the fixed ladder that is designed to surround the climbing space of the ladder","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.21","vehicles":[]},{"i":88,"id":"cfr/1910.212","section_id":"cfr/1910.212","title":"29 CFR 1910.212 General requirements for all machines","heading":"General requirements for all machines","text":"(a) Machine guarding \u2014(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are\u2014barrier guards, two-hand tripping devices, electronic safety devices, etc. (2) General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. (3) Point of operation guarding. (i) Point of operation is the area on a machine where work is actually performed upon the material being processed. (ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.212","vehicles":[]},{"i":89,"id":"cfr/1910.213","section_id":"cfr/1910.213","title":"29 CFR 1910.213 Woodworking machinery requirements","heading":"Woodworking machinery requirements","text":"(a) Machine construction general. (1) Each machine shall be so constructed as to be free from sensible vibration when the largest size tool is mounted and run idle at full speed. (2) Arbors and mandrels shall be constructed so as to have firm and secure bearing and be free from play. (3) [Reserved] (4) Any automatic cutoff saw that strokes continuously without the operator being able to control each stroke shall not be used. (5) Saw frames or tables shall be constructed with lugs cast on the frame or with an equivalent means to limit the size of the saw blade that can be mounted, so as to avoid overspeed caused by mounting a saw larger than intended. (6) Circular saw fences shall be so constructed that they can be firmly secured to the table or table assembly without changing their alignment with the saw. For saws with tilting tables or tilting arbors the fence shall be so constructed that it will remain in a line parallel with the saw,","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.213","vehicles":[]},{"i":90,"id":"cfr/1910.215","section_id":"cfr/1910.215","title":"29 CFR 1910.215 Abrasive wheel machinery","heading":"Abrasive wheel machinery","text":"(a) General requirements \u2014(1) Machine guarding. Abrasive wheels shall be used only on machines provided with safety guards as defined in the following paragraphs of this section, except: (i) Wheels used for internal work while within the work being ground; (ii) Mounted wheels, used in portable operations, 2 inches and smaller in diameter; and (iii) Types 16, 17, 18, 18R, and 19 cones, plugs, and threaded hole pot balls where the work offers protection. (2) Guard design. The safety guard shall cover the spindle end, nut, and flange projections. The safety guard shall be mounted so as to maintain proper alignment with the wheel, and the strength of the fastenings shall exceed the strength of the guard, except: (i) Safety guards on all operations where the work provides a suitable measure of protection to the operator, may be so constructed that the spindle end, nut, and outer flange are exposed; and where the nature of the work is such as","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.215","vehicles":[]},{"i":91,"id":"cfr/1910.216","section_id":"cfr/1910.216","title":"29 CFR 1910.216 Mills and calenders in the rubber and plastics industries","heading":"Mills and calenders in the rubber and plastics industries","text":"(a) General requirements \u2014 (1)-(2) [Reserved] (3) Auxiliary equipment. Mechanical and electrical equipment and auxiliaries shall be installed in accordance with this section and subpart S of this part. (4) Mill roll heights. All new mill installations shall be installed so that the top of the operating rolls is not less than 50 inches above the level on which the operator stands, irrespective of the size of the mill. This distance shall apply to the actual working level, whether it be at the general floor level, in a pit, or on a platform. (b) Mill safety controls \u2014(1) Safety trip control. A safety trip control shall be provided in front and in back of each mill. It shall be accessible and shall operate readily on contact. The safety trip control shall be one of the following types or a combination thereof: (i) Pressure-sensitive body bars. Installed at front and back of each mill having a 46-inch roll height or over. These bars shall o","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.216","vehicles":[]},{"i":92,"id":"cfr/1910.217","section_id":"cfr/1910.217","title":"29 CFR 1910.217 Mechanical power presses","heading":"Mechanical power presses","text":"(a) General requirements. (1)-(3) [Reserved] (4) Reconstruction and modification. It shall be the responsibility of any person reconstructing, or modifying a mechanical power press to do so in accordance with paragraph (b) of this section. (5) Excluded machines. Press brakes, hydraulic and pneumatic power presses, bulldozers, hot bending and hot metal presses, forging presses and hammers, riveting machines and similar types of fastener applicators are excluded from the requirements of this section. (b) Mechanical power press guarding and construction, general \u2014(1) Hazards to personnel associated with broken or falling machine components. Machine components shall be designed, secured, or covered to minimize hazards caused by breakage, or loosening and falling or release of mechanical energy (i.e. broken springs). (2) Brakes. Friction brakes provided for stopping or holding a slide movement shall be inherently self-engaging by requiring p","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.217","vehicles":[]},{"i":93,"id":"cfr/1910.218","section_id":"cfr/1910.218","title":"29 CFR 1910.218 Forging machines","heading":"Forging machines","text":"(a) General requirements \u2014(1) Use of lead. The safety requirements of this subparagraph apply to lead casts or other use of lead in the forge shop or die shop. (i) Thermostatic control of heating elements shall be provided to maintain proper melting temperature and prevent overheating. (ii) Fixed or permanent lead pot installations shall be exhausted. (iii) Portable units shall be used only in areas where good, general room ventilation is provided. (iv) Personal protective equipment (gloves, goggles, aprons, and other items) shall be worn. (v) A covered container shall be provided to store dross skimmings. (vi) Equipment shall be kept clean, particularly from accumulations of yellow lead oxide. (2) Inspection and maintenance. It shall be the responsibility of the employer to maintain all forge shop equipment in a condition which will insure continued safe operation. This responsibility includes: (i) Establishing periodic and regular mai","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.218","vehicles":[]},{"i":94,"id":"cfr/1910.219","section_id":"cfr/1910.219","title":"29 CFR 1910.219 Mechanical power-transmission apparatus","heading":"Mechanical power-transmission apparatus","text":"(a) General requirements. (1) This section covers all types and shapes of power-transmission belts, except the following when operating at two hundred and fifty (250) feet per minute or less: (i) Flat belts one (1) inch or less in width, (ii) flat belts two (2) inches or less in width which are free from metal lacings or fasteners, (iii) round belts one-half ( 1/2 ) inch or less in diameter; and (iv) single strand V-belts, the width of which is thirteen thirty-seconds ( 13/32 ) inch or less. (2) Vertical and inclined belts (paragraphs (e) (3) and (4) of this section) if not more than two and one-half (2 1/2 ) inches wide and running at a speed of less than one thousand (1,000) feet per minute, and if free from metal lacings or fastenings may be guarded with a nip-point belt and pulley guard. (3) For the Textile Industry, because of the presence of excessive deposits of lint, which constitute a serious fire hazard, the sides and face sec","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.219","vehicles":[]},{"i":95,"id":"cfr/1910.22","section_id":"cfr/1910.22","title":"29 CFR 1910.22 General requirements","heading":"General requirements","text":"(a) Surface conditions. The employer must ensure: (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. (2) The floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. When wet processes are used, drainage must be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats must be provided. (3) Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. (b) Loads. The employer must ensure that each walking-working surface can support the maximum intended load for that surface. (c) Access and egress. The employer must provide, and ensure each employee uses, a safe means of access and egress to and from walking-working surfaces. (d) Inspection, maintenance, and repair. The","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.22","vehicles":[]},{"i":96,"id":"cfr/1910.23","section_id":"cfr/1910.23","title":"29 CFR 1910.23 Ladders","heading":"Ladders","text":"(a) Application. The employer must ensure that each ladder used meets the requirements of this section. This section covers all ladders, except when the ladder is: (1) Used in emergency operations such as firefighting, rescue, and tactical law enforcement operations, or training for these operations; or (2) Designed into or is an integral part of machines or equipment. (b) General requirements for all ladders. The employer must ensure: (1) Ladder rungs, steps, and cleats are parallel, level, and uniformly spaced when the ladder is in position for use; (2) Ladder rungs, steps, and cleats are spaced not less than 10 inches (25 cm) and not more than 14 inches (36 cm) apart, as measured between the centerlines of the rungs, cleats, and steps, except that: (i) Ladder rungs and steps in elevator shafts must be spaced not less than 6 inches (15 cm) apart and not more than 16.5 inches (42 cm) apart, as measured along the ladder side rails; and ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.23","vehicles":[]},{"i":97,"id":"cfr/1910.24","section_id":"cfr/1910.24","title":"29 CFR 1910.24 Step bolts and manhole steps","heading":"Step bolts and manhole steps","text":"(a) Step bolts. The employer must ensure: (1) Each step bolt installed on or after January 17, 2017 in an environment where corrosion may occur is constructed of, or coated with, material that protects against corrosion; (2) Each step bolt is designed, constructed, and maintained to prevent the employee's foot from slipping off the end of the step bolt; (3) Step bolts are uniformly spaced at a vertical distance of not less than 12 inches (30 cm) and not more than 18 inches (46 cm) apart, measured center to center (see Figure D-6 of this section). The spacing from the entry and exit surface to the first step bolt may differ from the spacing between the other step bolts; (4) Each step bolt has a minimum clear width of 4.5 inches (11 cm); (5) The minimum perpendicular distance between the centerline of each step bolt to the nearest permanent object in back of the step bolt is 7 inches (18 cm). When the employer demonstrates that an obstruc","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.24","vehicles":[]},{"i":98,"id":"cfr/1910.242","section_id":"cfr/1910.242","title":"29 CFR 1910.242 Hand and portable powered tools and equipment, general","heading":"Hand and portable powered tools and equipment, general","text":"(a) General requirements. Each employer shall be responsible for the safe condition of tools and equipment used by employees, including tools and equipment which may be furnished by employees. (b) Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.242","vehicles":[]},{"i":99,"id":"cfr/1910.243","section_id":"cfr/1910.243","title":"29 CFR 1910.243 Guarding of portable powered tools","heading":"Guarding of portable powered tools","text":"(a) Portable powered tool \u2014(1) Portable circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in. shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to covering position. (ii) Paragraph (a)(1)(i) of this section does not apply to circular saws used in the meat industry for meat cutting purposes. (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater than 2 inches, electric, hydraulic or pneumatic chain saws, and percussion tools without po","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.243","vehicles":[]},{"i":100,"id":"cfr/1910.244","section_id":"cfr/1910.244","title":"29 CFR 1910.244 Other portable tools and equipment","heading":"Other portable tools and equipment","text":"(a) Jacks \u2014(1) Loading and marking. (i) The operator shall make sure that the jack used has a rating sufficient to lift and sustain the load. (ii) The rated load shall be legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means. (2) Operation and maintenance. (i) In the absence of a firm foundation, the base of the jack shall be blocked. If there is a possibility of slippage of the cap, a block shall be placed in between the cap and the load. (ii) The operator shall watch the stop indicator, which shall be kept clean, in order to determine the limit of travel. The indicated limit shall not be overrun. (iii) After the load has been raised, it shall be cribbed, blocked, or otherwise secured at once. (iv) Hydraulic jacks exposed to freezing temperatures shall be supplied with an adequate antifreeze liquid. (v) All jacks shall be properly lubricated at regular intervals. (vi) Each jack","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.244","vehicles":[]},{"i":101,"id":"cfr/1910.25","section_id":"cfr/1910.25","title":"29 CFR 1910.25 Stairways","heading":"Stairways","text":"(a) Application. This section covers all stairways (including standard, spiral, ship, and alternating tread-type stairs), except for articulated stairs (stairs that change pitch due to change in height at the point of attachment) such as those serving floating roof tanks, stairs on scaffolds, stairs designed into machines or equipment, and stairs on self-propelled motorized equipment. (b) General requirements. The employer must ensure: (1) Handrails, stair rail systems, and guardrail systems are provided in accordance with \u00a7 1910.28; (2) Vertical clearance above any stair tread to any overhead obstruction is at least 6 feet, 8 inches (203 cm), as measured from the leading edge of the tread. Spiral stairs must meet the vertical clearance requirements in paragraph (d)(3) of this section. (3) Stairs have uniform riser heights and tread depths between landings; (4) Stairway landings and platforms are at least the width of the stair and at l","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.25","vehicles":[]},{"i":102,"id":"cfr/1910.252","section_id":"cfr/1910.252","title":"29 CFR 1910.252 General requirements","heading":"General requirements","text":"(a) Fire prevention and protection \u2014(1) Basic precautions. For elaboration of these basic precautions and of the special precautions of paragraph (a)(2) of this section as well as a delineation of the fire protection and prevention responsibilities of welders and cutters, their supervisors (including outside contractors) and those in management on whose property cutting and welding is to be performed, see Standard for Fire Prevention in Use of Cutting and Welding Processes, NFPA Standard 51B, 1962, which is incorporated by reference as specified in \u00a7 1910.6. The basic precautions for fire prevention in welding or cutting work are: (i) Fire hazards. If the object to be welded or cut cannot readily be moved, all movable fire hazards in the vicinity shall be taken to a safe place. (ii) Guards. If the object to be welded or cut cannot be moved and if all the fire hazards cannot be removed, then guards shall be used to confine the heat, spar","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.252","vehicles":[]},{"i":103,"id":"cfr/1910.253","section_id":"cfr/1910.253","title":"29 CFR 1910.253 Oxygen-fuel gas welding and cutting","heading":"Oxygen-fuel gas welding and cutting","text":"(a) General requirements \u2014(1) Flammable mixture. Mixtures of fuel gases and air or oxygen may be explosive and shall be guarded against. No device or attachment facilitating or permitting mixtures of air or oxygen with flammable gases prior to consumption, except at the burner or in a standard torch, shall be allowed unless approved for the purpose. (2) Maximum pressure. Under no condition shall acetylene be generated, piped (except in approved cylinder manifolds) or utilized at a pressure in excess of 15 psig (103 kPa gauge pressure) or 30 psia (206 kPa absolute). The 30 psia (206 kPa absolute) limit is intended to prevent unsafe use of acetylene in pressurized chambers such as caissons, underground excavations or tunnel construction.) This requirement is not intended to apply to storage of acetylene dissolved in a suitable solvent in cylinders manufactured and maintained according to U.S. Department of Transportation requirements, or ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.253","vehicles":[]},{"i":104,"id":"cfr/1910.254","section_id":"cfr/1910.254","title":"29 CFR 1910.254 Arc welding and cutting","heading":"Arc welding and cutting","text":"(a) General \u2014(1) Equipment selection. Welding equipment shall be chosen for safe application to the work to be done as specified in paragraph (b) of this section. (2) Installation. Welding equipment shall be installed safely as specified by paragraph (c) of this section. (3) Instruction. Workmen designated to operate arc welding equipment shall have been properly instructed and qualified to operate such equipment as specified in paragraph (d) of this section. (b) Application of arc welding equipment \u2014(1) General. Assurance of consideration of safety in design is obtainable by choosing apparatus complying with the Requirements for Electric Arc-Welding Apparatus, NEMA EW-1-1962, National Electrical Manufacturers Association or the Safety Standard for Transformer-Type Arc-Welding Machines, ANSI C33.2\u20141956, Underwriters' Laboratories, both of which are incorporated by reference as specified in \u00a7 1910.6. (2) Environmental conditions. (i) Sta","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.254","vehicles":[]},{"i":105,"id":"cfr/1910.255","section_id":"cfr/1910.255","title":"29 CFR 1910.255 Resistance welding","heading":"Resistance welding","text":"(a) General \u2014(1) Installation. All equipment shall be installed by a qualified electrician in conformance with subpart S of this part. There shall be a safety-type disconnecting switch or a circuit breaker or circuit interrupter to open each power circuit to the machine, conveniently located at or near the machine, so that the power can be shut off when the machine or its controls are to be serviced. (2) Thermal protection. Ignitron tubes used in resistance welding equipment shall be equipped with a thermal protection switch. (3) Personnel. Workmen designated to operate resistance welding equipment shall have been properly instructed and judged competent to operate such equipment. (4) Guarding. Controls of all automatic or air and hydraulic clamps shall be arranged or guarded to prevent the operator from accidentally activating them. (b) Spot and seam welding machines (nonportable) \u2014(1) Voltage. All external weld initiating control circ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.255","vehicles":[]},{"i":106,"id":"cfr/1910.26","section_id":"cfr/1910.26","title":"29 CFR 1910.26 Dockboards","heading":"Dockboards","text":"The employer must ensure that each dockboard used meets the requirements of this section. The employer must ensure: (a) Dockboards are capable of supporting the maximum intended load in accordance with \u00a7 1910.22(b); (b)(1) Dockboards put into initial service on or after January 17, 2017 are designed, constructed, and maintained to prevent transfer vehicles from running off the dockboard edge; (2) Exception to paragraph (b)(1) of this section. When the employer demonstrates there is no hazard of transfer vehicles running off the dockboard edge, the employer may use dockboards that do not have run-off protection. (c) Portable dockboards are secured by anchoring them in place or using equipment or devices that prevent the dockboard from moving out of a safe position. When the employer demonstrates that securing the dockboard is not feasible, the employer must ensure there is sufficient contact between the dockboard and the surface to preve","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.26","vehicles":[]},{"i":107,"id":"cfr/1910.261","section_id":"cfr/1910.261","title":"29 CFR 1910.261 Pulp, paper, and paperboard mills","heading":"Pulp, paper, and paperboard mills","text":"(a) General requirements \u2014(1) Application. This section applies to establishments where pulp, paper, and paperboard are manufactured and converted. This section does not apply to logging and the transportation of logs to pulp, paper, and paperboard mills. (2) Standards incorporated by reference. Standards covering issues of occupational safety and health which have general application without regard to any specific industry are incorporated by reference in paragraphs (b) through (m) of this section and in subparagraphs (3) and (4) of this paragraph and made applicable under this section. Such standards shall be construed according to the rules set forth in \u00a7 1910.5. (3) General incorporation of standards. Establishments subject to this section shall comply with the following standards of the American National Standards Institute, which are incorporated by reference as specified in \u00a7 1910.6: (i) Practice for Industrial Lighting, A11.1\u201419","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.261","vehicles":[]},{"i":108,"id":"cfr/1910.262","section_id":"cfr/1910.262","title":"29 CFR 1910.262 Textiles","heading":"Textiles","text":"(a) Application requirements \u2014(1) Application. The requirements of this subpart for textile safety apply to the design, installation, processes, operation, and maintenance of textile machinery, equipment, and other plant facilities in all plants engaged in the manufacture and processing of textiles, except those processes used exclusively in the manufacture of synthetic fibers. (2) Standards incorporated by reference. Standards covering issues of occupational safety and health which are of general application without regard to any specific industry are incorporated by reference in paragraphs of this section and made applicable to textiles. All such standards shall be construed according to the rules of construction set out in \u00a7 1910.5. (b) Definitions applicable to this section \u2014(1) Belt shifter. A belt shifter is a device for mechanically shifting a belt from one pulley to another. (2) Belt shifter lock. A belt shifter lock is a device","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.262","vehicles":[]},{"i":109,"id":"cfr/1910.263","section_id":"cfr/1910.263","title":"29 CFR 1910.263 Bakery equipment","heading":"Bakery equipment","text":"(a) General requirements \u2014(1) Application. The requirements of this section shall apply to the design, installation, operation and maintenance of machinery and equipment used within a bakery. (2) [Reserved] (b) [Reserved] (c) General machine guarding. (1) [Reserved] (2) Gears. All gears shall be completely enclosed regardless of location. (3) Sprockets and V-belt drives. Sprockets and V-belt drives located within reach from platforms or pasageways or located within 8 feet 6 inches from the floor shall be completely enclosed. (4) [Reserved] (5) Lubrication. Where machinery must be lubricated while in motion, stationary lubrication fittings inside a machine shall be provided with extension piping to a point of safety so that the employee will not have to reach into any dangerous part of the machine when lubricating. (6)-(7) [Reserved] (8) Hot pipes. Exposed hot water and steam pipes shall be covered with insulating material wherever neces","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.263","vehicles":[]},{"i":110,"id":"cfr/1910.264","section_id":"cfr/1910.264","title":"29 CFR 1910.264 Laundry machinery and operations","heading":"Laundry machinery and operations","text":"(a) [Reserved] (b) General requirements. This section applies to moving parts of equipment used in laundries and to conditions peculiar to this industry, with special reference to the point of operation of laundry machines. This section does not apply to dry-cleaning operations. (c) Point-of-operation guards \u2014(1) Washroom machines. (i) [Reserved] (ii) Washing machine. ( a ) [Reserved] ( b ) Each washing machine shall be provided with means for holding open the doors or covers of inner and outer cylinders or shells while being loaded or unloaded. (2) Starching and drying machines. (i)-(ii) [Reserved] (iii) Drying tumbler. ( a ) [Reserved] ( b ) Each drying tumbler shall be provided with means for holding open the doors or covers of inner and outer cylinders or shells while being loaded or unloaded. (iv) Shaker (clothes tumbler). ( a ) through ( b )( 1 ) [Reserved] ( 2 ) Each shaker or clothes tumbler of the double-cylinder type shall be ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.264","vehicles":[]},{"i":111,"id":"cfr/1910.265","section_id":"cfr/1910.265","title":"29 CFR 1910.265 Sawmills","heading":"Sawmills","text":"(a) General requirements\u2014Application. This section includes safety requirements for sawmill operations including, but not limited to, log and lumber handling, sawing, trimming, and planing; waste disposal; operation of dry kilns; finishing; shipping; storage; yard and yard equipment; and for power tools and affiliated equipment used in connection with such operations, but excluding the manufacture of plywood, cooperage, and veneer. (b) Definitions applicable to this section \u2014(1) A-frame. The term A-frame means a structure made of two independent columns fastened together at the top and separated at the bottom for stability. (2) Annealing. The term annealing means heating then cooling to soften and render less brittle. (3) Binder. The term binder means a chain, cable, rope, or other approved material used for binding loads. (4) Boom. The term boom means logs or timbers fastened together end to end and used to contain floating logs. The t","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.265","vehicles":[]},{"i":112,"id":"cfr/1910.266","section_id":"cfr/1910.266","title":"29 CFR 1910.266 Logging operations","heading":"Logging operations","text":"(a) Table of contents. This paragraph contains the list of paragraphs and appendices contained in this section. a. Table of contents b. Scope and application c. Definitions d. General requirements 1. Personal protective equipment 2. First-aid kits 3. Seat belts 4. Fire extinguishers 5. Environmental conditions 6. Work areas 7. Signaling and signal equipment 8. Overhead electric lines 9. Flammable and combustible liquids 10. Explosives and blasting agents e. Hand and portable powered tools 1. General requirements 2. Chain saws f. Machines 1. General requirements 2. Machine operation 3. Protective structures 4. Overhead guards 5. Machine access 6. Exhaust systems 7. Brakes 8. Guarding g. Vehicles h. Tree harvesting 1. General requirements 2. Manual felling 3. Bucking and limbing 4. Chipping 5. Yarding 6. Loading and unloading 7. Transport 8. Storage i. Training j. Appendices Appendix A\u2014Minimum First-aid Supplies Appendix B\u2014Minimum First-a","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.266","vehicles":[]},{"i":113,"id":"cfr/1910.268","section_id":"cfr/1910.268","title":"29 CFR 1910.268 Telecommunications","heading":"Telecommunications","text":"(a) Application. (1) This section sets forth safety and health standards that apply to the work conditions, practices, means, methods, operations, installations and processes performed at telecommunications centers and at telecommunications field installations, which are located outdoors or in building spaces used for such field installations. Center work includes the installation, operation, maintenance, rearrangement, and removal of communications equipment and other associated equipment in telecommunications switching centers. Field work includes the installation, operation, maintenance, rearrangement, and removal of conductors and other equipment used for signal or communication service, and of their supporting or containing structures, overhead or underground, on public or private rights of way, including buildings or other structures. (2) These standards do not apply: (i) To construction work, as defined in \u00a7 1910.12, nor (ii) to ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.268","vehicles":[]},{"i":114,"id":"cfr/1910.269","section_id":"cfr/1910.269","title":"29 CFR 1910.269 Electric power generation, transmission, and distribution","heading":"Electric power generation, transmission, and distribution","text":"(a) General \u2014(1) Application. (i) This section covers the operation and maintenance of electric power generation, control, transformation, transmission, and distribution lines and equipment. These provisions apply to: (A) Power generation, transmission, and distribution installations, including related equipment for the purpose of communication or metering that are accessible only to qualified employees; Note to paragraph ( a )(1)( i )(A): The types of installations covered by this paragraph include the generation, transmission, and distribution installations of electric utilities, as well as equivalent installations of industrial establishments. Subpart S of this part covers supplementary electric generating equipment that is used to supply a workplace for emergency, standby, or similar purposes only. (See paragraph (a)(1)(i)(B) of this section.) (B) Other installations at an electric power generating station, as follows: ( 1 ) Fuel an","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.269","vehicles":[]},{"i":115,"id":"cfr/1910.27","section_id":"cfr/1910.27","title":"29 CFR 1910.27 Scaffolds and rope descent systems","heading":"Scaffolds and rope descent systems","text":"(a) Scaffolds. Scaffolds used in general industry must meet the requirements in 29 CFR part 1926, subpart L (Scaffolds). (b) Rope descent systems \u2014(1) Anchorages. (i) Before any rope descent system is used, the building owner must inform the employer, in writing that the building owner has identified, tested, certified, and maintained each anchorage so it is capable of supporting at least 5,000 pounds (2,268 kg), in any direction, for each employee attached. The information must be based on an annual inspection by a qualified person and certification of each anchorage by a qualified person, as necessary, and at least every 10 years. (ii) The employer must ensure that no employee uses any anchorage before the employer has obtained written information from the building owner that each anchorage meets the requirements of paragraph (b)(1)(i) of this section. The employer must keep the information for the duration of the job. (iii) The requi","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.27","vehicles":[]},{"i":116,"id":"cfr/1910.272","section_id":"cfr/1910.272","title":"29 CFR 1910.272 Grain handling facilities","heading":"Grain handling facilities","text":"(a) Scope. This section contains requirements for the control of grain dust fires and explosions, and certain other safety hazards associated with grain handling facilities. It applies in addition to all other relevant provisions of part 1910 (or part 1917 at marine terminals). Note to paragraph ( a ): For grain-handling facilities in the marine-terminal industry only, 29 CFR 1910.272 is to be enforced consistent with the interpretations in OSHA Compliance Directive 02-00-066, which is available on OSHA's Web page at www.osha.gov. (b) Application. (1) Paragraphs (a) through (n) of this section apply to grain elevators, feed mills, flour mills, rice mills, dust pelletizing plants, dry corn mills, soybean flaking operations, and the dry grinding operations of soycake. (2) Paragraphs (o), (p), and (q) of this section apply only to grain elevators. (c) Definitions. Choked leg means a condition of material buildup in the bucket elevator that","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.272","vehicles":[]},{"i":117,"id":"cfr/1910.28","section_id":"cfr/1910.28","title":"29 CFR 1910.28 Duty to have fall protection and falling object protection","heading":"Duty to have fall protection and falling object protection","text":"(a) General. (1) This section requires employers to provide protection for each employee exposed to fall and falling object hazards. Unless stated otherwise, the employer must ensure that all fall protection and falling object protection required by this section meet the criteria in \u00a7 1910.29, except that personal fall protection systems required by this section meet the criteria of \u00a7 1910.140. (2) This section does not apply: (i) To portable ladders; (ii) When employers are inspecting, investigating, or assessing workplace conditions or work to be performed prior to the start of work or after all work has been completed. This exemption does not apply when fall protection systems or equipment meeting the requirements of \u00a7 1910.29 have been installed and are available for workers to use for pre-work and post-work inspections, investigations, or assessments; (iii) To fall hazards presented by the exposed perimeters of entertainment stages","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.28","vehicles":[]},{"i":118,"id":"cfr/1910.29","section_id":"cfr/1910.29","title":"29 CFR 1910.29 Fall protection systems and falling object protection\u2014criteria and practices","heading":"Fall protection systems and falling object protection\u2014criteria and practices","text":"(a) General requirements. The employer must: (1) Ensure each fall protection system and falling object protection, other than personal fall protection systems, that this part requires meets the requirements in this section. The employer must ensure each personal fall protection system meets the requirements in subpart I of this part; and (2) Provide and install all fall protection systems and falling object protection this subpart requires, and comply with the other requirements in this subpart before any employee begins work that necessitates fall or falling object protection. (b) Guardrail systems. The employer must ensure guardrail systems meet the following requirements: (1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other c","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.29","vehicles":[]},{"i":119,"id":"cfr/1910.3","section_id":"cfr/1910.3","title":"29 CFR 1910.3 Petitions for the issuance, amendment, or repeal of a standard","heading":"Petitions for the issuance, amendment, or repeal of a standard","text":"(a) Any interested person may petition in writing the Assistant Secretary of Labor to promulgate, modify, or revoke a standard. The petition should set forth the terms or the substance of the rule desired, the effects thereof if promulgated, and the reasons therefor. (b)(1) The relevant legislative history of the Act indicates congressional recognition of the American National Standards Institute and the National Fire Protection Association as the major sources of national consensus standards. National consensus standards adopted on May 29, 1971, pursuant to section 6(a) of the Act are from those two sources. However, any organization which deems itself a producer of national consensus standards, within the meaning of section 3(9) of the Act, is invited to submit in writing to the Assistant Secretary of Labor at any time prior to February 1, 1973, all relevant information which may enable the Assistant Secretary to determine whether any","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.3","vehicles":[]},{"i":120,"id":"cfr/1910.30","section_id":"cfr/1910.30","title":"29 CFR 1910.30 Training requirements","heading":"Training requirements","text":"(a) Fall hazards. (1) Before any employee is exposed to a fall hazard, the employer must provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart. Employers must ensure employees are trained in the requirements of this paragraph on or before May 17, 2017. (2) The employer must ensure that each employee is trained by a qualified person. (3) The employer must train each employee in at least the following topics: (i) The nature of the fall hazards in the work area and how to recognize them; (ii) The procedures to be followed to minimize those hazards; (iii) The correct procedures for installing, inspecting, operating, maintaining, and disassembling the personal fall protection systems that the employee uses; and (iv) The correct use of personal fall protection systems and equipment specified in paragraph (a)(1) of this section, including, but not li","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.30","vehicles":[]},{"i":121,"id":"cfr/1910.301","section_id":"cfr/1910.301","title":"29 CFR 1910.301 Introduction","heading":"Introduction","text":"This subpart addresses electrical safety requirements that are necessary for the practical safeguarding of employees in their workplaces and is divided into four major divisions as follows: (a) Design safety standards for electrical systems. These regulations are contained in \u00a7\u00a7 1910.302 through 1910.330. Sections 1910.302 through 1910.308 contain design safety standards for electric utilization systems. Included in this category are all electric equipment and installations used to provide electric power and light for employee workplaces. Sections 1910.309 through 1910.330 are reserved for possible future design safety standards for other electrical systems. (b) Safety-related work practices. These regulations will be contained in \u00a7\u00a7 1910.331 through 1910.360. (c) Safety-related maintenance requirements. These regulations will be contained in \u00a7\u00a7 1910.361 through 1910.380. (d) Safety requirements for special equipment. These regulations ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.301","vehicles":[]},{"i":122,"id":"cfr/1910.302","section_id":"cfr/1910.302","title":"29 CFR 1910.302 Electric utilization systems","heading":"Electric utilization systems","text":"Sections 1910.302 through 1910.308 contain design safety standards for electric utilization systems. (a) Scope \u2014(1) Covered. The provisions of \u00a7\u00a7 1910.302 through 1910.308 cover electrical installations and utilization equipment installed or used within or on buildings, structures, and other premises, including: (i) Yards; (ii) Carnivals; (iii) Parking and other lots; (iv) Mobile homes; (v) Recreational vehicles; (vi) Industrial substations; (vii) Conductors that connect the installations to a supply of electricity; and (viii) Other outside conductors on the premises. (2) Not covered. The provisions of \u00a7\u00a7 1910.302 through 1910.308 do not cover: (i) Installations in ships, watercraft, railway rolling stock, aircraft, or automotive vehicles other than mobile homes and recreational vehicles; (ii) Installations underground in mines; (iii) Installations of railways for generation, transformation, transmission, or distribution of power used e","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.302","vehicles":[]},{"i":123,"id":"cfr/1910.303","section_id":"cfr/1910.303","title":"29 CFR 1910.303 General","heading":"General","text":"(a) Approval. The conductors and equipment required or permitted by this subpart shall be acceptable only if approved, as defined in \u00a7 1910.399. (b) Examination, installation, and use of equipment \u2014(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations: (i) Suitability for installation and use in conformity with the provisions of this subpart; Note to paragraph ( b )(1)( i ) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose. (ii) Mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided; (iii) Wire-bending and connection space; (iv) Electrical insulation; (v) Heating effects under all conditions of u","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.303","vehicles":[]},{"i":124,"id":"cfr/1910.304","section_id":"cfr/1910.304","title":"29 CFR 1910.304 Wiring design and protection","heading":"Wiring design and protection","text":"(a) Use and identification of grounded and grounding conductors \u2014(1) Identification of conductors. (i) A conductor used as a grounded conductor shall be identifiable and distinguishable from all other conductors. (ii) A conductor used as an equipment grounding conductor shall be identifiable and distinguishable from all other conductors. (2) Polarity of connections. No grounded conductor may be attached to any terminal or lead so as to reverse designated polarity. (3) Use of grounding terminals and devices. A grounding terminal or grounding-type device on a receptacle, cord connector, or attachment plug may not be used for purposes other than grounding. (b) Branch circuits \u2014(1) Identification of multiwire branch circuits. Where more than one nominal voltage system exists in a building containing multiwire branch circuits, each ungrounded conductor of a multiwire branch circuit, where accessible, shall be identified by phase and system. ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.304","vehicles":[]},{"i":125,"id":"cfr/1910.305","section_id":"cfr/1910.305","title":"29 CFR 1910.305 Wiring methods, components, and equipment for general use","heading":"Wiring methods, components, and equipment for general use","text":"(a) Wiring methods. The provisions of this section do not apply to conductors that are an integral part of factory-assembled equipment. (1) General requirements. (i) Metal raceways, cable trays, cable armor, cable sheath, enclosures, frames, fittings, and other metal noncurrent-carrying parts that are to serve as grounding conductors, with or without the use of supplementary equipment grounding conductors, shall be effectively bonded where necessary to ensure electrical continuity and the capacity to conduct safely any fault current likely to be imposed on them. Any nonconductive paint, enamel, or similar coating shall be removed at threads, contact points, and contact surfaces or be connected by means of fittings designed so as to make such removal unnecessary. (ii) Where necessary for the reduction of electrical noise (electromagnetic interference) of the grounding circuit, an equipment enclosure supplied by a branch circuit may be is","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.305","vehicles":[]},{"i":126,"id":"cfr/1910.306","section_id":"cfr/1910.306","title":"29 CFR 1910.306 Specific purpose equipment and installations","heading":"Specific purpose equipment and installations","text":"(a) Electric signs and outline lighting \u2014(1) Disconnecting means. (i) Each sign and outline lighting system, or feeder circuit or branch circuit supplying a sign or outline lighting system, shall be controlled by an externally operable switch or circuit breaker that will open all ungrounded conductors. However, a disconnecting means is not required for an exit directional sign located within a building or for cord-connected signs with an attachment plug. (ii) Signs and outline lighting systems located within fountains shall have the disconnect located at least 1.52 m (5.0 ft) from the inside walls of the fountain. (2) Location. (i) The disconnecting means shall be within sight of the sign or outline lighting system that it controls. Where the disconnecting means is out of the line of sight from any section that may be energized, the disconnecting means shall be capable of being locked in the open position. (ii) Signs or outline lighting","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.306","vehicles":[]},{"i":127,"id":"cfr/1910.307","section_id":"cfr/1910.307","title":"29 CFR 1910.307 Hazardous (classified) locations","heading":"Hazardous (classified) locations","text":"(a) Scope \u2014(1) Applicability. This section covers the requirements for electric equipment and wiring in locations that are classified depending on the properties of the flammable vapors, liquids or gases, or combustible dusts or fibers that may be present therein and the likelihood that a flammable or combustible concentration or quantity is present. Hazardous (classified) locations may be found in occupancies such as, but not limited to, the following: aircraft hangars, gasoline dispensing and service stations, bulk storage plants for gasoline or other volatile flammable liquids, paint-finishing process plants, health care facilities, agricultural or other facilities where excessive combustible dusts may be present, marinas, boat yards, and petroleum and chemical processing plants. Each room, section or area shall be considered individually in determining its classification. (2) Classifications. (i) These hazardous (classified) locatio","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.307","vehicles":[]},{"i":128,"id":"cfr/1910.308","section_id":"cfr/1910.308","title":"29 CFR 1910.308 Special systems","heading":"Special systems","text":"(a) Systems over 600 volts, nominal. This paragraph covers the general requirements for all circuits and equipment operated at over 600 volts. (1) Aboveground wiring methods. (i) Aboveground conductors shall be installed in rigid metal conduit, in intermediate metal conduit, in electrical metallic tubing, in rigid nonmetallic conduit, in cable trays, as busways, as cablebus, in other identified raceways, or as open runs of metal-clad cable suitable for the use and purpose. In locations accessible to qualified persons only, open runs of Type MV cables, bare conductors, and bare busbars are also permitted. Busbars shall be either copper or aluminum. Open runs of insulated wires and cables having a bare lead sheath or a braided outer covering shall be supported in a manner designed to prevent physical damage to the braid or sheath. (ii) Conductors emerging from the ground shall be enclosed in approved raceways. (2) Braid-covered insulated ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.308","vehicles":[]},{"i":129,"id":"cfr/1910.33","section_id":"cfr/1910.33","title":"29 CFR 1910.33 Table of contents","heading":"Table of contents","text":"This section lists the sections and paragraph headings contained in \u00a7\u00a7 1910.34 through 1910.39. \u00a7 1910.34 Coverage and definitions. (a) Every employer is covered. (b) Exit routes are covered. (c) Definitions. \u00a7 1910.35 Compliance with Alternate Exit Route Codes. \u00a7 1910.36 Design and construction requirements for exit routes. (a) Basic requirements. (b) The number of exit routes must be adequate. (c) Exit discharge. (d) An exit door must be unlocked. (e) A side-hinged exit door must be used. (f) The capacity of an exit route must be adequate. (g) An exit route must meet minimum height and width requirements. (h) An outdoor exit route is permitted. \u00a7 1910.37 Maintenance, safeguards, and operational features for exit routes. (a) The danger to employees must be minimized. (b) Lighting and marking must be adequate and appropriate. (c) The fire retardant properties of paints or solutions must be maintained. (d) Exit routes must be maintained ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.33","vehicles":[]},{"i":130,"id":"cfr/1910.332","section_id":"cfr/1910.332","title":"29 CFR 1910.332 Training","heading":"Training","text":"(a) Scope. The training requirements contained in this section apply to employees who face a risk of electric shock that is not reduced to a safe level by the electrical installation requirements of \u00a7\u00a7 1910.303 through 1910.308. Note: Employees in occupations listed in Table S-4 face such a risk and are required to be trained. Other employees who also may reasonably be expected to face a comparable risk of injury due to electric shock or other electrical hazards must also be trained. (b) Content of training \u2014(1) Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by \u00a7\u00a7 1910.331 through 1910.335 that pertain to their respective job assignments. (2) Additional requirements for unqualified persons. Employees who are covered by paragraph (a) of this section but who are not qualified persons shall also be trained in and familiar with any electrically related safety ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.332","vehicles":[]},{"i":131,"id":"cfr/1910.333","section_id":"cfr/1910.333","title":"29 CFR 1910.333 Selection and use of work practices","heading":"Selection and use of work practices","text":"(a) General. Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards. (1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs. Note 1: Examples of increased or additional hazards include interruption of life support eq","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.333","vehicles":[]},{"i":132,"id":"cfr/1910.334","section_id":"cfr/1910.334","title":"29 CFR 1910.334 Use of equipment","heading":"Use of equipment","text":"(a) Portable electric equipment. This paragraph applies to the use of cord- and plug-connected equipment, including flexible cord sets (extension cords). (1) Handling. Portable equipment shall be handled in a manner which will not cause damage. Flexible electric cords connected to equipment may not be used for raising or lowering the equipment. Flexible cords may not be fastened with staples or otherwise hung in such a fashion as could damage the outer jacket or insulation. (2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.334","vehicles":[]},{"i":133,"id":"cfr/1910.335","section_id":"cfr/1910.335","title":"29 CFR 1910.335 Safeguards for personnel protection","heading":"Safeguards for personnel protection","text":"(a) Use of protective equipment \u2014(1) Personal protective equipment. (i) Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. Note: Personal protective equipment requirements are contained in subpart I of this part. (ii) Protective equipment shall be maintained in a safe, reliable condition and shall be periodically inspected or tested, as required by \u00a7 1910.137. (iii) If the insulating capability of protective equipment may be subject to damage during use, the insulating material shall be protected. (For example, an outer covering of leather is sometimes used for the protection of rubber insulating material.) (iv) Employees shall wear nonconductive head protection wherever there is a danger of head injury from electric shock or burns due to cont","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.335","vehicles":[]},{"i":134,"id":"cfr/1910.34","section_id":"cfr/1910.34","title":"29 CFR 1910.34 Coverage and definitions","heading":"Coverage and definitions","text":"(a) Every employer is covered. Sections 1910.34 through 1910.39 apply to workplaces in general industry except mobile workplaces such as vehicles or vessels. (b) Exits routes are covered. The rules in \u00a7\u00a7 1910.34 through 1910.39 cover the minimum requirements for exit routes that employers must provide in their workplace so that employees may evacuate the workplace safely during an emergency. Sections 1910.34 through 1910.39 also cover the minimum requirements for emergency action plans and fire prevention plans. (c) Definitions. Electroluminescent means a light-emitting capacitor. Alternating current excites phosphor atoms when placed between the electrically conductive surfaces to produce light. This light source is typically contained inside the device. Exit means that portion of an exit route that is generally separated from other areas to provide a protected way of travel to the exit discharge. An example of an exit is a two-hour fi","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.34","vehicles":[]},{"i":135,"id":"cfr/1910.35","section_id":"cfr/1910.35","title":"29 CFR 1910.35 Compliance with alternate exit-route codes","heading":"Compliance with alternate exit-route codes","text":"OSHA will deem an employer demonstrating compliance with the exit-route provisions of NFPA 101, Life Safety Code, 2009 edition, or the exit-route provisions of the International Fire Code, 2009 edition, to be in compliance with the corresponding requirements in \u00a7\u00a7 1910.34, 1910.36, and 1910.37 (incorporated by reference, see section \u00a7 1910.6). [76 FR 33606, June 8, 2011]","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.35","vehicles":[]},{"i":136,"id":"cfr/1910.36","section_id":"cfr/1910.36","title":"29 CFR 1910.36 Design and construction requirements for exit routes","heading":"Design and construction requirements for exit routes","text":"(a) Basic requirements. Exit routes must meet the following design and construction requirements: (1) An exit route must be permanent. Each exit route must be a permanent part of the workplace. (2) An exit must be separated by fire resistant materials. Construction materials used to separate an exit from other parts of the workplace must have a one-hour fire resistance-rating if the exit connects three or fewer stories and a two-hour fire resistance-rating if the exit connects four or more stories. (3) Openings into an exit must be limited. An exit is permitted to have only those openings necessary to allow access to the exit from occupied areas of the workplace, or to the exit discharge. An opening into an exit must be protected by a self-closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be list","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.36","vehicles":[]},{"i":137,"id":"cfr/1910.37","section_id":"cfr/1910.37","title":"29 CFR 1910.37 Maintenance, safeguards, and operational features for exit routes","heading":"Maintenance, safeguards, and operational features for exit routes","text":"(a) The danger to employees must be minimized. (1) Exit routes must be kept free of explosive or highly flammable furnishings or other decorations. (2) Exit routes must be arranged so that employees will not have to travel toward a high hazard area, unless the path of travel is effectively shielded from the high hazard area by suitable partitions or other physical barriers. (3) Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. (4) Safeguards designed to protect employees during an emergency ( e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times. (b)","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.37","vehicles":[]},{"i":138,"id":"cfr/1910.38","section_id":"cfr/1910.38","title":"29 CFR 1910.38 Emergency action plans","heading":"Emergency action plans","text":"(a) Application. An employer must have an emergency action plan whenever an OSHA standard in this part requires one. The requirements in this section apply to each such emergency action plan. (b) Written and oral emergency action plans. An emergency action plan must be in writing, kept in the workplace, and available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees. (c) Minimum elements of an emergency action plan. An emergency action plan must include at a minimum: (1) Procedures for reporting a fire or other emergency; (2) Procedures for emergency evacuation, including type of evacuation and exit route assignments; (3) Procedures to be followed by employees who remain to operate critical plant operations before they evacuate; (4) Procedures to account for all employees after evacuation; (5) Procedures to be followed by employees performing rescue or medical duties; a","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.38","vehicles":[]},{"i":139,"id":"cfr/1910.39","section_id":"cfr/1910.39","title":"29 CFR 1910.39 Fire prevention plans","heading":"Fire prevention plans","text":"(a) Application. An employer must have a fire prevention plan when an OSHA standard in this part requires one. The requirements in this section apply to each such fire prevention plan. (b) Written and oral fire prevention plans. A fire prevention plan must be in writing, be kept in the workplace, and be made available to employees for review. However, an employer with 10 or fewer employees may communicate the plan orally to employees. (c) Minimum elements of a fire prevention plan. A fire prevention plan must include: (1) A list of all major fire hazards, proper handling and storage procedures for hazardous materials, potential ignition sources and their control, and the type of fire protection equipment necessary to control each major hazard; (2) Procedures to control accumulations of flammable and combustible waste materials; (3) Procedures for regular maintenance of safeguards installed on heat-producing equipment to prevent the acci","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.39","vehicles":[]},{"i":140,"id":"cfr/1910.399","section_id":"cfr/1910.399","title":"29 CFR 1910.399 Definitions applicable to this subpart","heading":"Definitions applicable to this subpart","text":"Acceptable. An installation or equipment is acceptable to the Assistant Secretary of Labor, and approved within the meaning of this subpart S: (1) If it is accepted, or certified, or listed, or labeled, or otherwise determined to be safe by a nationally recognized testing laboratory recognized pursuant to \u00a7 1910.7; or (2) With respect to an installation or equipment of a kind that no nationally recognized testing laboratory accepts, certifies, lists, labels, or determines to be safe, if it is inspected or tested by another Federal agency, or by a State, municipal, or other local authority responsible for enforcing occupational safety provisions of the National Electrical Code, and found in compliance with the provisions of the National Electrical Code as applied in this subpart; or (3) With respect to custom-made equipment or related installations that are designed, fabricated for, and intended for use by a particular customer, if it is","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.399","vehicles":[]},{"i":141,"id":"cfr/1910.4","section_id":"cfr/1910.4","title":"29 CFR 1910.4 Amendments to this part","heading":"Amendments to this part","text":"(a) The Assistant Secretary of Labor shall have all of the authority of the Secretary of Labor under sections 3(9) and 6(a) of the Act. (b) The Assistant Secretary of Labor may at any time before April 28, 1973, on his own motion or upon the written petition of any person, by rule promulgate as a standard any national consensus standard and any established Federal standard, pursuant to and in accordance with section 6(a) of the Act, and, in addition, may modify or revoke any standard in this part 1910. In the event of conflict among any such standards, the Assistant Secretary of Labor shall take the action necessary to eliminate the conflict, including the revocation or modification of a standard in this part, so as to assure the greatest protection of the safety or health of the affected employees.","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.4","vehicles":[]},{"i":142,"id":"cfr/1910.401","section_id":"cfr/1910.401","title":"29 CFR 1910.401 Scope and application","heading":"Scope and application","text":"(a) Scope. (1) This subpart (standard) applies to every place of employment within the waters of the United States, or within any State, the District of Columbia, the Commonwealth of Puerto Rico, the Virgin Islands, American Samoa, Guam, the Trust Territory of the Pacific Islands, Wake Island, Johnston Island, the Canal Zone, or within the Outer Continental Shelf lands as defined in the Outer Continental Shelf Lands Act (67 Stat. 462, 43 U.S.C. 1331), where diving and related support operations are performed. (2) This standard applies to diving and related support operations conducted in connection with all types of work and employments, including general industry, construction, ship repairing, shipbuilding, shipbreaking and longshoring. However, this standard does not apply to any diving operation: (i) Performed solely for instructional purposes, using open-circuit, compressed-air SCUBA and conducted within the no-decompression limits;","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.401","vehicles":[]},{"i":143,"id":"cfr/1910.410","section_id":"cfr/1910.410","title":"29 CFR 1910.410 Qualifications of dive team","heading":"Qualifications of dive team","text":"(a) General. (1) Each dive team member shall have the experience or training necessary to perform assigned tasks in a safe and healthful manner. (2) Each dive team member shall have experience or training in the following: (i) The use of tools, equipment and systems relevant to assigned tasks; (ii) Techniques of the assigned diving mode: and (iii) Diving operations and emergency procedures. (3) All dive team members shall be trained in cardiopulmonary resuscitation and first aid (American Red Cross standard course or equivalent). (4) Dive team members who are exposed to or control the exposure of others to hyperbaric conditions shall be trained in diving-related physics and physiology. (b) Assignments. (1) Each dive team member shall be assigned tasks in accordance with the employee's experience or training, except that limited additional tasks may be assigned to an employee undergoing training provided that these tasks are performed un","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.410","vehicles":[]},{"i":144,"id":"cfr/1910.420","section_id":"cfr/1910.420","title":"29 CFR 1910.420 Safe practices manual","heading":"Safe practices manual","text":"(a) General. The employer shall develop and maintain a safe practices manual which shall be made available at the dive location to each dive team member. (b) Contents. (1) The safe practices manual shall contain a copy of this standard and the employer's policies for implementing the requirements of this standard. (2) For each diving mode engaged in, the safe practices manual shall include: (i) Safety procedures and checklists for diving operations; (ii) Assignments and responsibilities of the dive team members; (iii) Equipment procedures and checklists; and (iv) Emergency procedures for fire, equipment failure, adverse environmental conditions, and medical illness and injury. [42 FR 37668, July 22, 1977, as amended at 49 FR 18295, Apr. 30, 1984]","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.420","vehicles":[]},{"i":145,"id":"cfr/1910.421","section_id":"cfr/1910.421","title":"29 CFR 1910.421 Pre-dive procedures","heading":"Pre-dive procedures","text":"(a) General. The employer shall comply with the following requirements prior to each diving operation, unless otherwise specified. (b) Emergency aid. A list shall be kept at the dive location of the telephone or call numbers of the following: (1) An operational decompression chamber (if not at the dive location); (2) Accessible hospitals; (3) Available physicians; (4) Available means of transportation; and (5) The nearest U.S. Coast Guard Rescue Coordination Center. (c) First aid supplies. (1) A first aid kit appropriate for the diving operation and approved by a physician shall be available at the dive location. (2) When used in a decompression chamber or bell, the first aid kit shall be suitable for use under hyperbaric conditions. (3) In addition to any other first aid supplies, an American Red Cross standard first aid handbook or equivalent, and a bag-type manual resuscitator with transparent mask and tubing shall be available at th","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.421","vehicles":[]},{"i":146,"id":"cfr/1910.422","section_id":"cfr/1910.422","title":"29 CFR 1910.422 Procedures during dive","heading":"Procedures during dive","text":"(a) General. The employer shall comply with the following requirements which are applicable to each diving operation unless otherwise specified. (b) Water entry and exit. (1) A means capable of supporting the diver shall be provided for entering and exiting the water. (2) The means provided for exiting the water shall extend below the water surface. (3) A means shall be provided to assist an injured diver from the water or into a bell. (c) Communications. (1) An operational two-way voice communication system shall be used between: (i) Each surface-supplied air or mixed-gas diver and a dive team member at the dive location or bell (when provided or required); and (ii) The bell and the dive location. (2) An operational, two-way communication system shall be available at the dive location to obtain emergency assistance. (d) Decompression tables. Decompression, repetitive, and no-decompression tables (as appropriate) shall be at the dive lo","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.422","vehicles":[]},{"i":147,"id":"cfr/1910.423","section_id":"cfr/1910.423","title":"29 CFR 1910.423 Post-dive procedures","heading":"Post-dive procedures","text":"(a) General. The employer shall comply with the following requirements which are applicable after each diving operation, unless otherwise specified. (b) Precautions. (1) After the completion of any dive, the employer shall: (i) Check the physical condition of the diver; (ii) Instruct the diver to report any physical problems or adverse physiological effects including symptoms of decompression sickness; (iii) Advise the diver of the location of a decompression chamber which is ready for use; and (iv) Alert the diver to the potential hazards of flying after diving. (2) For any dive outside the no-decompression limits, deeper than 100 fsw or using mixed gas as a breathing mixture, the employer shall instruct the diver to remain awake and in the vicinity of the decompression chamber which is at the dive location for at least one hour after the dive (including decompression or treatment as appropriate). (c) Recompression capability. (1) A de","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.423","vehicles":[]},{"i":148,"id":"cfr/1910.424","section_id":"cfr/1910.424","title":"29 CFR 1910.424 SCUBA diving","heading":"SCUBA diving","text":"(a) General. Employers engaged in SCUBA diving shall comply with the following requirements, unless otherwise specified. (b) Limits. SCUBA diving shall not be conducted: (1) At depths deeper than 130 fsw; (2) At depths deeper than 100 fsw or outside the no-decompression limits unless a decompression chamber is ready for use; (3) Against currents exceeding one (1) knot unless line-tended; or (4) In enclosed or physically confining spaces unless line-tended. (c) Procedures. (1) A standby diver shall be available while a diver is in the water. (2) A diver shall be line-tended from the surface, or accompanied by another diver in the water in continuous visual contact during the diving operations. (3) A diver shall be stationed at the underwater point of entry when diving is conducted in enclosed or physically confining spaces. (4) A diver-carried reserve breathing gas supply shall be provided for each diver consisting of: (i) A manual reser","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.424","vehicles":[]},{"i":149,"id":"cfr/1910.425","section_id":"cfr/1910.425","title":"29 CFR 1910.425 Surface-supplied air diving","heading":"Surface-supplied air diving","text":"(a) General. Employers engaged in surface-supplied air diving shall comply with the following requirements, unless otherwise specified. (b) Limits. (1) Surface-supplied air diving shall not be conducted at depths deeper than 190 fsw, except that dives with bottom times of 30 minutes or less may be conducted to depths of 220 fsw. (2) A decompression chamber shall be ready for use at the dive location for any dive outside the no-decompression limits or deeper than 100 fsw. (3) A bell shall be used for dives with an inwater decompression time greater than 120 minutes, except when heavy gear is worn or diving is conducted in physically confining spaces. (c) Procedures. (1) Each diver shall be continuously tended while in the water. (2) A diver shall be stationed at the underwater point of entry when diving is conducted in enclosed or physically confining spaces. (3) Each diving operation shall have a primary breathing gas supply sufficient ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.425","vehicles":[]},{"i":150,"id":"cfr/1910.426","section_id":"cfr/1910.426","title":"29 CFR 1910.426 Mixed-gas diving","heading":"Mixed-gas diving","text":"(a) General. Employers engaged in mixed-gas diving shall comply with the following requirements, unless otherwise specified. (b) Limits. Mixed-gas diving shall be conducted only when: (1) A decompression chamber is ready for use at the dive location; and (i) A bell is used at depths greater than 220 fsw or when the dive involves inwater decompression time of greater than 120 minutes, except when heavy gear is worn or when diving in physically confining spaces; or (ii) A closed bell is used at depths greater than 300 fsw, except when diving is conducted in physically confining spaces. (c) Procedures. (1) A separate dive team member shall tend each diver in the water. (2) A standby diver shall be available while a diver is in the water. (3) A diver shall be stationed at the underwater point of entry when diving is conducted in enclosed or physically confining spaces. (4) Each diving operation shall have a primary breathing gas supply suff","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.426","vehicles":[]},{"i":151,"id":"cfr/1910.427","section_id":"cfr/1910.427","title":"29 CFR 1910.427 Liveboating","heading":"Liveboating","text":"(a) General. Employers engaged in diving operations involving liveboating shall comply with the following requirements. (b) Limits. Diving operations involving liveboating shall not be conducted: (1) With an inwater decompression time of greater than 120 minutes; (2) Using surface-supplied air at depths deeper than 190 fsw, except that dives with bottom times of 30 minutes or less may be conducted to depths of 220 fsw; (3) Using mixed gas at depths greater than 220 fsw; (4) In rough seas which significantly inpede diver mobility or work function; or (5) In other than daylight hours. (c) Procedures. (1) The propeller of the vessel shall be stopped before the diver enters or exits the water. (2) A device shall be used which minimizes the possibility of entanglement of the diver's hose in the propeller of the vessel. (3) Two-way voice communication between the designated person-in-charge and the person controlling the vessel shall be avail","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.427","vehicles":[]},{"i":152,"id":"cfr/1910.430","section_id":"cfr/1910.430","title":"29 CFR 1910.430 Equipment","heading":"Equipment","text":"(a) General. (1) All employers shall comply with the following requirements, unless otherwise specified. (2) Each equipment modification, repair, test, calibration or maintenance service shall be recorded by means of a tagging or logging system, and include the date and nature of work performed, and the name or initials of the person performing the work. (b) Air compressor system. (1) Compressors used to supply air to the diver shall be equipped with a volume tank with a check valve on the inlet side, a pressure gauge, a relief valve, and a drain valve. (2) Air compressor intakes shall be located away from areas containing exhaust or other contaminants. (3) Respirable air supplied to a diver shall not contain: (i) A level of carbon monoxide (CO) greater than 20 p/m; (ii) A level of carbon dioxide (CO 2 ) greater than 1,000 p/m; (iii) A level of oil mist greater than 5 milligrams per cubic meter; or (iv) A noxious or pronounced odor. (4)","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.430","vehicles":[]},{"i":153,"id":"cfr/1910.440","section_id":"cfr/1910.440","title":"29 CFR 1910.440 Recordkeeping requirements","heading":"Recordkeeping requirements","text":"(a)(1) [Reserved] (2) The employer shall record the occurrence of any diving-related injury or illness which requires any dive team member to be hospitalized for 24 hours or more, specifying the circumstances of the incident and the extent of any injuries or illnesses. (b) Availability of records. (1) Upon the request of the Assistant Secretary of Labor for Occupational Safety and Health, or the Director, National Institute for Occupational Safety and Health, Department of Health and Human Services of their designees, the employer shall make available for inspection and copying any record or document required by this standard. (2) Records and documents required by this standard shall be provided upon request to employees, designated representatives, and the Assistant Secretary in accordance with 29 CFR 1910.1020 (a)-(e) and (g)-(i). Safe practices manuals (\u00a7 1910.420), depth-time profiles (\u00a7 1910.422), recordings of dives (\u00a7 1910.423), ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.440","vehicles":[]},{"i":154,"id":"cfr/1910.5","section_id":"cfr/1910.5","title":"29 CFR 1910.5 Applicability of standards","heading":"Applicability of standards","text":"(a) Except as provided in paragraph (b) of this section, the standards contained in this Part shall apply with respect to employments performed in a workplace in a State, the District of Columbia, the Commonwealth of Puerto Rico, the Virgin Islands, American Samoa, Guam, the Commonwealth of the Northern Mariana Islands, Wake Island, Outer Continental Shelf lands defined in the Outer Continental Shelf Lands Act, and Johnston Island. (b) None of the standards in this part shall apply to working conditions of employees with respect to which Federal agencies other than the Department of Labor, or State agencies acting under section 274 of the Atomic Energy Act of 1954, as amended (42 U.S.C. 2021), exercise statutory authority to prescribe or enforce standards or regulations affecting occupational safety or health. (c)(1) If a particular standard is specifically applicable to a condition, practice, means, method, operation, or process, it sh","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.5","vehicles":[]},{"i":155,"id":"cfr/1910.502","section_id":"cfr/1910.502","title":"29 CFR 1910.502 Healthcare","heading":"Healthcare","text":"(a) Scope and application. (1) Except as otherwise provided in this paragraph, this section applies to all settings where any employee provides healthcare services or healthcare support services. (2) This section does not apply to the following: (i) The provision of first aid by an employee who is not a licensed healthcare provider; (ii) The dispensing of prescriptions by pharmacists in retail settings; (iii) Non-hospital ambulatory care settings where all non-employees are screened prior to entry and people with suspected or confirmed COVID-19 are not permitted to enter those settings; (iv) Well-defined hospital ambulatory care settings where all employees are fully vaccinated and all non-employees are screened prior to entry and people with suspected or confirmed COVID-19 are not permitted to enter those settings; (v) Home healthcare settings where all employees are fully vaccinated and all non-employees are screened prior to entry an","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.502","vehicles":[]},{"i":156,"id":"cfr/1910.504","section_id":"cfr/1910.504","title":"29 CFR 1910.504 Mini Respiratory Protection Program","heading":"Mini Respiratory Protection Program","text":"(a) Scope and application. This section applies only to respirator use in accordance with \u00a7 1910.502(f)(4). (b) Definitions. The following definitions apply to this section: COVID-19 (Coronavirus Disease 2019) means the respiratory disease caused by SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2). For clarity and ease of reference, this section refers to \u201cCOVID-19\u201d when describing exposures or potential exposures to SARS-CoV-2. Elastomeric respirator means a tight-fitting respirator with a facepiece that is made of synthetic or rubber material that permits it to be disinfected, cleaned, and reused according to manufacturer's instructions. It is equipped with a replaceable cartridge(s), canister(s), or filter(s). Filtering facepiece respirator means a negative-pressure particulate respirator with a non-replaceable filter as an integral part of the facepiece or with the entire facepiece composed of the non-replaceable filteri","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.504","vehicles":[]},{"i":157,"id":"cfr/1910.505","section_id":"cfr/1910.505","title":"29 CFR 1910.505 Severability","heading":"Severability","text":"Each section of this subpart U, and each provision within those sections, is separate and severable from the other sections and provisions. If any provision of this subpart is held to be invalid or unenforceable on its face, or as applied to any person, entity, or circumstance, or is stayed or enjoined, that provision shall be construed so as to continue to give the maximum effect to the provision permitted by law, unless such holding shall be one of utter invalidity or unenforceability, in which event the provision shall be severable from this subpart and shall not affect the remainder of the subpart.","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.505","vehicles":[]},{"i":158,"id":"cfr/1910.509","section_id":"cfr/1910.509","title":"29 CFR 1910.509 Incorporation by reference","heading":"Incorporation by reference","text":"(a)(1) The material listed in this section is incorporated by reference into this subpart with the approval of the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than that specified in this section, OSHA must publish a document in the Federal Register and the material must be available to the public. All approved material is available for inspection at any Regional Office of the Occupational Safety and Health Administration (OSHA), or at the OSHA Docket Office, U.S. Department of Labor, 200 Constitution Avenue NW, Room N-3508, Washington, DC 20210; telephone: 202-693-2350 (TTY number: 877-889-5627). It is also available for inspection at the National Archives and Records Administration (NARA). For information on the availability of these standards at NARA, email fedreg.legal@nara.gov , or go to www.archives.gov/federal-register/cfr/ibr-locations.html . (2) The material","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.509","vehicles":[]},{"i":159,"id":"cfr/1910.6","section_id":"cfr/1910.6","title":"29 CFR 1910.6 Incorporation by reference","heading":"Incorporation by reference","text":"(a)(1) Certain material is incorporated by reference into this part with the approval of the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. To enforce any edition other than that specified in this section, the Occupational Safety and Health Administration (OSHA) must publish a document in the Federal Register and the material must be available to the public. (i) The standards of agencies of the U.S. Government, and organizations which are not agencies of the U.S. Government which are incorporated by reference in this part, have the same force and effect as other standards in this part. Only the mandatory provisions ( i.e., provisions containing the word \u201cshall\u201d or other mandatory language) of standards incorporated by reference are adopted as standards under the Occupational Safety and Health Act. (ii) Any changes in the standards incorporated by reference in this part and an official historic fil","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.6","vehicles":[]},{"i":160,"id":"cfr/1910.66","section_id":"cfr/1910.66","title":"29 CFR 1910.66 Powered platforms for building maintenance","heading":"Powered platforms for building maintenance","text":"(a) Scope. This section covers powered platform installations permanently dedicated to interior or exterior building maintenance of a specific structure or group of structures. This section does not apply to suspended scaffolds (swinging scaffolds) used to service buildings on a temporary basis and covered under subpart D of this part, nor to suspended scaffolds used for construction work and covered under subpart L of 29 CFR part 1926. Building maintenance includes, but is not limited to, such tasks as window cleaning, caulking, metal polishing and reglazing. (b) Application \u2014(1) New installations. This section applies to all permanent installations completed after July 23, 1990. Major modifications to existing installations completed after that date are also considered new installations under this section. (2) Existing installations. (i) Permanent installations in existence and/or completed before July 23, 1990 shall comply with parag","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.66","vehicles":[]},{"i":161,"id":"cfr/1910.67","section_id":"cfr/1910.67","title":"29 CFR 1910.67 Vehicle-mounted elevating and rotating work platforms","heading":"Vehicle-mounted elevating and rotating work platforms","text":"(a) Definitions applicable to this section \u2014(1) Aerial device. Any vehicle\u2014mounted device, telescoping or articulating, or both, which is used to position personnel. (2) Aerial ladder. An aerial device consisting of a single- or multiple-section extensible ladder. (3) Articulating boom platform. An aerial device with two or more hinged boom sections. (4) Extensible boom platform. An aerial device (except ladders) with a telescopic or extensible boom. Telescopic derricks with personnel platform attachments shall be considered to be extensible boom platforms when used with a personnel platform. (5) Insulated aerial device. An aerial device designed for work on energized lines and apparatus. (6) Mobile unit. A combination of an aerial device, its vehicle, and related equipment. (7) Platform. Any personnel-carrying device (basket or bucket) which is a component of an aerial device. (8) Vehicle. Any carrier that is not manually propelled. (9","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.67","vehicles":[]},{"i":162,"id":"cfr/1910.68","section_id":"cfr/1910.68","title":"29 CFR 1910.68 Manlifts","heading":"Manlifts","text":"(a) Definitions applicable to this section \u2014(1) Handhold (Handgrip). A handhold is a device attached to the belt which can be grasped by the passenger to provide a means of maintaining balance. (2) Open type. One which has a handgrip surface fully exposed and capable of being encircled by the passenger's fingers. (3) Closed type. A cup-shaped device, open at the top in the direction of travel of the step for which it is to be used, and closed at the bottom, into which the passenger may place his fingers. (4) Limit switch. A device, the purpose of which is to cut off the power to the motor and apply the brake to stop the carrier in the event that a loaded step passes the terminal landing. (5) Manlift. A device consisting of a power-driven endless belt moving in one direction only, and provided with steps or platforms and handholds attached to it for the transportation of personnel from floor to floor. (6) Rated speed. Rated speed is the ","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.68","vehicles":[]},{"i":163,"id":"cfr/1910.7","section_id":"cfr/1910.7","title":"29 CFR 1910.7 Definition and requirements for a nationally recognized testing laboratory","heading":"Definition and requirements for a nationally recognized testing laboratory","text":"(a) Application. This section shall apply only when the term nationally recognized testing laboratory is used in other sections of this part. (b) Laboratory requirements. The term nationally recognized testing laboratory (NRTL) means an organization which is recognized by OSHA in accordance with appendix A of this section and which tests for safety, and lists or labels or accepts, equipment or materials and which meets all of the following criteria: (1) For each specified item of equipment or material to be listed, labeled or accepted, the NRTL has the capability (including proper testing equipment and facilities, trained staff, written testing procedures, and calibration and quality control programs) to perform: (i) Testing and examining of equipment and materials for workplace safety purposes to determine conformance with appropriate test standards; or (ii) Experimental testing and examining of equipment and materials for workplace sa","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.7","vehicles":[]},{"i":164,"id":"cfr/1910.8","section_id":"cfr/1910.8","title":"29 CFR 1910.8 OMB control numbers under the Paperwork Reduction Act","heading":"OMB control numbers under the Paperwork Reduction Act","text":"The following sections or paragraphs each contain a collection of information requirement which has been approved by the Office of Management and Budget under the control number listed. 29 CFR citation OMB control No. 1910.7 1218-0147 1910.23 1218-0199 1910.27 1218-0199 1910.28 1218-0199 1910.66 1218-0121 1910.67(b) 1218-0230 1910.68 1218-0226 1910.95 1218-0048 1910.111 1218-0208 1910.119 1218-0200 1910.120 1218-0202 1910.132 1218-0205 1910.134 1218-0099 1910.137 1218-0190 1910.142 1218-0096 1910.145 1218-0132 1910.146 1218-0203 1910.147 1218-0150 1910.156 1218-0075 1910.157(e)(3) 1218-0210 1910.157(f)(16) 1218-0218 1910.177(d)(3)(iv) 1218-0219 1910.179(j)(2)(iii) and (iv) 1218-0224 1910.179(m)(1) and (m)(2) 1218-0224 1910.180(d)(6) 1218-0221 1910.180(g)(1) and (g)(2)(ii) 1218-0221 1910.181(g)(1) and (g)(3) 1218-0222 1910.184(e)(4), (f)(4) and (i)(8)(ii) 1218-0223 1910.217(e)(1)(i) and (ii) 1218-0229 1910.217(g) 1218-0070 1910.217(h) 12","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.8","vehicles":[]},{"i":165,"id":"cfr/1910.9","section_id":"cfr/1910.9","title":"29 CFR 1910.9 Compliance duties owed to each employee","heading":"Compliance duties owed to each employee","text":"(a) Personal protective equipment. Standards in this part requiring the employer to provide personal protective equipment (PPE), including respirators and other types of PPE, because of hazards to employees impose a separate compliance duty with respect to each employee covered by the requirement. The employer must provide PPE to each employee required to use the PPE, and each failure to provide PPE to an employee may be considered a separate violation. (b) Training. Standards in this part requiring training on hazards and related matters, such as standards requiring that employees receive training or that the employer train employees, provide training to employees, or institute or implement a training program, impose a separate compliance duty with respect to each employee covered by the requirement. The employer must train each affected employee in the manner required by the standard, and each failure to train an employee may be consi","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.9","vehicles":[]},{"i":166,"id":"cfr/1910.94","section_id":"cfr/1910.94","title":"29 CFR 1910.94 Ventilation","heading":"Ventilation","text":"(a) Abrasive blasting \u2014(1) Definitions applicable to this paragraph \u2014(i) Abrasive. A solid substance used in an abrasive blasting operation. (ii) Abrasive-blasting respirator. A respirator constructed so that it covers the wearer's head, neck, and shoulders to protect the wearer from rebounding abrasive. (iii) Blast cleaning barrel. A complete enclosure which rotates on an axis, or which has an internal moving tread to tumble the parts, in order to expose various surfaces of the parts to the action of an automatic blast spray. (iv) Blast cleaning room. A complete enclosure in which blasting operations are performed and where the operator works inside of the room to operate the blasting nozzle and direct the flow of the abrasive material. (v) Blasting cabinet. An enclosure where the operator stands outside and operates the blasting nozzle through an opening or openings in the enclosure. (vi) Clean air. Air of such purity that it will not","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.94","vehicles":[]},{"i":167,"id":"cfr/1910.95","section_id":"cfr/1910.95","title":"29 CFR 1910.95 Occupational noise exposure","heading":"Occupational noise exposure","text":"(a) Protection against the effects of noise exposure shall be provided when the sound levels exceed those shown in Table G-16 when measured on the A scale of a standard sound level meter at slow response. When noise levels are determined by octave band analysis, the equivalent A-weighted sound level may be determined as follows: EC27OC91.023 Figure G-9 Equivalent sound level contours. Octave band sound pressure levels may be converted to the equivalent A-weighted sound level by plotting them on this graph and noting the A-weighted sound level corresponding to the point of highest penetration into the sound level contours. This equivalent A-weighted sound level, which may differ from the actual A-weighted sound level of the noise, is used to determine exposure limits from Table 1.G-16. (b)(1) When employees are subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls shall be utilized. If s","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.95","vehicles":[]},{"i":168,"id":"cfr/1910.97","section_id":"cfr/1910.97","title":"29 CFR 1910.97 Nonionizing radiation","heading":"Nonionizing radiation","text":"(a) Electromagnetic radiation \u2014(1) Definitions applicable to this paragraph. (i) The term electromagnetic radiation is restricted to that portion of the spectrum commonly defined as the radio frequency region, which for the purpose of this specification shall include the microwave frequency region. (ii) Partial body irradiation. Pertains to the case in which part of the body is exposed to the incident electromagnetic energy. (iii) Radiation protection guide. Radiation level which should not be exceeded without careful consideration of the reasons for doing so. (iv) The word \u201csymbol\u201d as used in this specification refers to the overall design, shape, and coloring of the rf radiation sign shown in figure G-11. (v) Whole body irradiation. Pertains to the case in which the entire body is exposed to the incident electromagnetic energy or in which the cross section of the body is smaller than the cross section of the incident radiation beam. (","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.97","vehicles":[]},{"i":169,"id":"cfr/1910.98","section_id":"cfr/1910.98","title":"29 CFR 1910.98 Effective dates","heading":"Effective dates","text":"(a) The provisions of this subpart G shall become effective on August 27, 1971, except as provided in the remaining paragraphs of this section. (b) The following provisions shall become effective on February 15, 1972: \u00a7 1910.94 (a)(2)(iii), (a)(3), (a)(4), (b), (c)(2), (c)(3), (c)(4), (c)(5), (c)(6)(i), (c)(6)(ii), (d)(1)(ii), (d)(3), (d)(4), (d)(5), and (d)(7). (c) Notwithstanding anything in paragraph (a), (b), or (d) of this section, any provision in any other section of this subpart which contains in itself a specific effective date or time limitation shall become effective on such date or shall apply in accordance with such limitation. (d) Notwithstanding anything in paragraph (a) of this section, if any standard in 41 CFR part 50-204, other than a national consensus standard incorporated by reference in \u00a7 50-204.2(a)(1), is or becomes applicable at any time to any employment and place of employment, by virtue of the Walsh-Healey P","url":"https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.98","vehicles":[]}]