| from datetime import datetime | |
| from sqlalchemy import Column, Integer, String, Float, Boolean, DateTime, JSON, Text, Index | |
| from database.base import Base | |
| # ============================================================================== | |
| # VARIABLE SPEED BASED OPTIMIZATIONS TABLES (VFD FANS, PUMPS, TOWERS) | |
| # ============================================================================== | |
| # 1. Variable Speed Equipment Registry | |
| class VariableSpeedEquipmentDB(Base): | |
| __tablename__ = "variable_speed_equipment" | |
| id = Column(String, primary_key=True) # e.g. "AHU-FAN-01", "CHW-PUMP-01", "CT-FAN-01" | |
| equipment_type = Column(String, nullable=False) # "AHU_FAN", "SUPPLY_FAN", "RETURN_FAN", "CHW_PUMP", "HHW_PUMP", "CW_PUMP", "COOLING_TOWER_FAN" | |
| building_id = Column(String, default="BLD-01") | |
| name = Column(String, nullable=False) | |
| manufacturer = Column(String, default="Schneider / ABB") | |
| rated_power_kw = Column(Float, nullable=False) # e.g. 18.4 kW, 22.0 kW, 30.0 kW | |
| rated_speed_rpm = Column(Float, default=1750.0) | |
| minimum_speed_pct = Column(Float, default=30.0) # VFD minimum safe speed clamp | |
| maximum_speed_pct = Column(Float, default=100.0) | |
| minimum_frequency_hz = Column(Float, default=20.0) # Motor cooling limit | |
| maximum_frequency_hz = Column(Float, default=60.0) | |
| design_flow = Column(Float, nullable=False) # CFM for fans, GPM for pumps | |
| flow_unit = Column(String, default="GPM") # "CFM" or "GPM" | |
| design_pressure = Column(Float, nullable=False) # in.w.c. for fans, PSI / ft head for pumps | |
| pressure_unit = Column(String, default="PSI") # "in.w.c.", "PSI", "ft_hd" | |
| efficiency = Column(Float, default=0.92) | |
| vfd_enabled = Column(Boolean, default=True) | |
| control_mode = Column(String, default="AUTO_CLOSED_LOOP") # "ADVISORY", "AUTO", "AUTO_CLOSED_LOOP", "MANUAL" | |
| status = Column(String, default="RUNNING") # "RUNNING", "STANDBY", "OPTIMAL", "FAULT" | |
| # 2. Variable Speed Telemetry | |
| class VariableSpeedTelemetryDB(Base): | |
| __tablename__ = "variable_speed_telemetry" | |
| id = Column(Integer, primary_key=True, autoincrement=True) | |
| timestamp = Column(DateTime, default=datetime.utcnow, index=True) | |
| building_id = Column(String, default="BLD-01") | |
| equipment_id = Column(String, nullable=False) | |
| point_id = Column(String, nullable=False) | |
| point_name = Column(String, nullable=False) | |
| value = Column(Float, nullable=False) | |
| unit = Column(String, nullable=False) | |
| quality = Column(String, default="GOOD") # GOOD | BAD | UNCERTAIN | STALE | MISSING | |
| source = Column(String, default="BACnet_IP") | |
| received_at = Column(DateTime, default=datetime.utcnow) | |
| opportunity_id = Column(String, nullable=True) | |
| __table_args__ = ( | |
| Index("ix_vs_tel_eq_ts", "equipment_id", "timestamp"), | |
| Index("ix_vs_tel_point_ts", "point_id", "timestamp"), | |
| ) | |
| # 3. VFD Fan Measurements | |
| class VFDFanMeasurementDB(Base): | |
| __tablename__ = "vfd_fan_measurements" | |
| id = Column(Integer, primary_key=True, autoincrement=True) | |
| timestamp = Column(DateTime, default=datetime.utcnow, index=True) | |
| equipment_id = Column(String, nullable=False) | |
| fan_speed_pct = Column(Float, nullable=False) | |
| fan_frequency_hz = Column(Float, nullable=False) | |
| fan_power_kw = Column(Float, nullable=False) | |
| fan_airflow_cfm = Column(Float, nullable=False) | |
| duct_static_pressure_inwc = Column(Float, nullable=False) | |
| static_pressure_setpoint_inwc = Column(Float, default=1.20) | |
| vav_airflow_demand_cfm = Column(Float, default=6500.0) | |
| avg_vav_damper_pct = Column(Float, default=65.0) | |
| max_vav_damper_pct = Column(Float, default=82.0) | |
| critical_zones_count = Column(Integer, default=1) | |
| specific_fan_power = Column(Float, default=1.65) # kW/(m3/s) | |
| # 4. VFD Pump Measurements | |
| class VFDPumpMeasurementDB(Base): | |
| __tablename__ = "vfd_pump_measurements" | |
| id = Column(Integer, primary_key=True, autoincrement=True) | |
| timestamp = Column(DateTime, default=datetime.utcnow, index=True) | |
| equipment_id = Column(String, nullable=False) | |
| pump_type = Column(String, nullable=False) # "CHW_PUMP", "HHW_PUMP", "CW_PUMP", "SECONDARY_PUMP" | |
| pump_speed_pct = Column(Float, nullable=False) | |
| pump_frequency_hz = Column(Float, nullable=False) | |
| pump_power_kw = Column(Float, nullable=False) | |
| flow_gpm = Column(Float, nullable=False) | |
| differential_pressure_psi = Column(Float, nullable=False) | |
| dp_setpoint_psi = Column(Float, default=14.0) | |
| supply_temp_c = Column(Float, default=6.7) | |
| return_temp_c = Column(Float, default=12.2) | |
| delta_t_c = Column(Float, default=5.5) | |
| chiller_load_pct = Column(Float, default=68.0) | |
| valve_positions_avg_pct = Column(Float, default=72.0) | |
| # 5. VFD Inverter Measurements | |
| class VfdMeasurementDB(Base): | |
| __tablename__ = "vfd_measurements" | |
| id = Column(Integer, primary_key=True, autoincrement=True) | |
| timestamp = Column(DateTime, default=datetime.utcnow, index=True) | |
| equipment_id = Column(String, nullable=False) | |
| frequency_hz = Column(Float, nullable=False) | |
| output_voltage_v = Column(Float, default=460.0) | |
| output_current_a = Column(Float, default=26.5) | |
| motor_rpm = Column(Float, default=1450.0) | |
| dc_bus_voltage_v = Column(Float, default=650.0) | |
| inverter_temp_c = Column(Float, default=42.5) | |
| vfd_fault_code = Column(String, default="NORMAL_00") | |
| power_factor = Column(Float, default=0.94) | |
| # 6. Optimization Predictions (ML Output) | |
| class VariableSpeedPredictionDB(Base): | |
| __tablename__ = "variable_speed_predictions" | |
| id = Column(String, primary_key=True) | |
| timestamp = Column(DateTime, default=datetime.utcnow, index=True) | |
| equipment_id = Column(String, nullable=False) | |
| agent_id = Column(String, nullable=False) | |
| model_version = Column(String, default="v2.5.0-xgb-affinity") | |
| current_speed = Column(Float, nullable=False) | |
| recommended_speed = Column(Float, nullable=False) | |
| current_power_kw = Column(Float, nullable=False) | |
| predicted_power_kw = Column(Float, nullable=False) | |
| power_savings_kw = Column(Float, default=0.0) | |
| predicted_flow = Column(Float, nullable=False) | |
| predicted_pressure = Column(Float, nullable=False) | |
| confidence = Column(Float, default=0.96) | |
| safety_status = Column(String, default="PASS") | |
| status = Column(String, default="OPTIMAL") | |
| reason = Column(Text, nullable=False) | |
| # 7. Optimization Recommendations | |
| class VariableSpeedRecommendationDB(Base): | |
| __tablename__ = "variable_speed_recommendations" | |
| recommendation_id = Column(String, primary_key=True) | |
| opportunity_id = Column(String, nullable=False) # "VS-FAN", "VS-PUMP", "VS-CHW", "VS-CW", "VS-CT" | |
| equipment_id = Column(String, nullable=False) | |
| current_speed = Column(Float, nullable=False) | |
| recommended_speed = Column(Float, nullable=False) | |
| current_power_kw = Column(Float, nullable=False) | |
| predicted_power_kw = Column(Float, nullable=False) | |
| expected_savings_kw = Column(Float, default=0.0) | |
| expected_savings_kwh_day = Column(Float, default=0.0) | |
| confidence = Column(Float, default=0.96) | |
| reason = Column(Text, nullable=False) | |
| safety_status = Column(String, default="PASS") | |
| dispatch_status = Column(String, default="READY") | |
| timestamp = Column(DateTime, default=datetime.utcnow) | |
| # 8. Optimization Actions (BMS Dispatches) | |
| class VariableSpeedActionDB(Base): | |
| __tablename__ = "variable_speed_actions" | |
| id = Column(String, primary_key=True) | |
| recommendation_id = Column(String, nullable=True) | |
| equipment_id = Column(String, nullable=False) | |
| opportunity_id = Column(String, nullable=False) | |
| target_point = Column(String, nullable=False) # e.g. "AHU-FAN-01.SpeedSetpoint" | |
| dispatched_value = Column(Float, nullable=False) | |
| previous_value = Column(Float, nullable=False) | |
| unit = Column(String, default="%") | |
| priority_level = Column(Integer, default=10) | |
| dispatched_by = Column(String, default="VARIABLE_SPEED_AI") | |
| timestamp = Column(DateTime, default=datetime.utcnow) | |
| bms_status = Column(String, default="ACKNOWLEDGED") | |
| # 9. Optimization Results (15-min M&V) | |
| class VariableSpeedResultDB(Base): | |
| __tablename__ = "variable_speed_results" | |
| id = Column(Integer, primary_key=True, autoincrement=True) | |
| action_id = Column(String, nullable=False) | |
| equipment_id = Column(String, nullable=False) | |
| timestamp = Column(DateTime, default=datetime.utcnow) | |
| baseline_power_kw = Column(Float, default=0.0) | |
| optimized_power_kw = Column(Float, default=0.0) | |
| measured_power_savings_kw = Column(Float, default=0.0) | |
| verified_energy_savings_kwh = Column(Float, default=0.0) | |
| airflow_comfort_preserved = Column(Boolean, default=True) | |
| pressure_preserved = Column(Boolean, default=True) | |
| verification_outcome = Column(String, default="VERIFIED_KEPT") # "VERIFIED_KEPT", "ROLLED_BACK" | |
| # 10. Safety Constraints & Guardrails | |
| class VariableSpeedSafetyConstraintDB(Base): | |
| __tablename__ = "variable_speed_safety_constraints" | |
| id = Column(String, primary_key=True) | |
| equipment_id = Column(String, nullable=False) | |
| rule_name = Column(String, nullable=False) | |
| min_speed_pct = Column(Float, nullable=False) | |
| max_speed_pct = Column(Float, nullable=False) | |
| min_flow = Column(Float, nullable=False) | |
| max_flow = Column(Float, nullable=False) | |
| min_pressure = Column(Float, nullable=False) | |
| max_pressure = Column(Float, nullable=False) | |
| min_frequency_hz = Column(Float, default=20.0) | |
| max_frequency_hz = Column(Float, default=60.0) | |
| ramp_rate_limit_pct_per_min = Column(Float, default=10.0) | |
| is_active = Column(Boolean, default=True) | |
| # 11. Model Versions | |
| class VariableSpeedModelVersionDB(Base): | |
| __tablename__ = "variable_speed_model_versions" | |
| id = Column(String, primary_key=True) | |
| agent_id = Column(String, nullable=False) | |
| version = Column(String, nullable=False) | |
| algorithm = Column(String, default="XGBoost_Affinity_Hybrid") | |
| trained_timestamp = Column(DateTime, default=datetime.utcnow) | |
| mae_power_kw = Column(Float, default=0.28) | |
| rmse_power_kw = Column(Float, default=0.45) | |
| r2_score = Column(Float, default=0.975) | |
| status = Column(String, default="PRODUCTION") # "PRODUCTION", "STAGING", "MODEL_DEGRADED" | |
| # 12. Energy Savings Measurement | |
| class VariableSpeedEnergySavingsDB(Base): | |
| __tablename__ = "variable_speed_energy_savings" | |
| id = Column(Integer, primary_key=True, autoincrement=True) | |
| timestamp = Column(DateTime, default=datetime.utcnow, index=True) | |
| equipment_id = Column(String, nullable=False) | |
| category = Column(String, nullable=False) # "FAN", "PUMP", "CHW", "CW", "TOWER" | |
| predicted_savings_kw = Column(Float, default=0.0) | |
| measured_savings_kw = Column(Float, default=0.0) | |
| verified_savings_kwh = Column(Float, default=0.0) | |
| calculation_method = Column(String, default="IPMVP_Option_B") | |
| # 13. Audit Logs | |
| class VariableSpeedAuditLogDB(Base): | |
| __tablename__ = "variable_speed_audit_logs" | |
| id = Column(Integer, primary_key=True, autoincrement=True) | |
| timestamp = Column(DateTime, default=datetime.utcnow, index=True) | |
| agent = Column(String, nullable=False) | |
| equipment_id = Column(String, nullable=False) | |
| current_value = Column(Float, nullable=False) | |
| recommended_value = Column(Float, nullable=False) | |
| final_value = Column(Float, nullable=False) | |
| reason = Column(Text, nullable=False) | |
| model_version = Column(String, default="v2.5.0") | |
| confidence = Column(Float, default=0.96) | |
| safety_result = Column(String, default="PASS") | |
| operator_mode = Column(String, default="AUTO_CLOSED_LOOP") | |
| dispatch_result = Column(String, default="SUCCESS") | |
| verification_result = Column(String, default="VERIFIED_KEPT") | |
| rollback_result = Column(String, nullable=True) | |
| details = Column(JSON, nullable=True) | |