| Interactive camera calibration application {#tutorial_interactive_calibration} | |
| ============================== | |
| @tableofcontents | |
| @prev_tutorial{tutorial_real_time_pose} | |
| @next_tutorial{tutorial_usac} | |
| | | | | |
| | -: | :- | | |
| | Original author | Vladislav Sovrasov | | |
| | Compatibility | OpenCV >= 3.1 | | |
| According to classical calibration technique user must collect all data first and when run @ref cv::calibrateCamera function | |
| to obtain camera parameters. If average re-projection error is huge or if estimated parameters seems to be wrong, process of | |
| selection or collecting data and starting of @ref cv::calibrateCamera repeats. | |
| Interactive calibration process assumes that after each new data portion user can see results and errors estimation, also | |
| he can delete last data portion and finally, when dataset for calibration is big enough starts process of auto data selection. | |
| Main application features | |
| ------ | |
| The sample application will: | |
| - Determine the distortion matrix and confidence interval for each element | |
| - Determine the camera matrix and confidence interval for each element | |
| - Take input from camera or video file | |
| - Read configuration from XML file | |
| - Save the results into XML file | |
| - Calculate re-projection error | |
| - Reject patterns views on sharp angles to prevent appear of ill-conditioned jacobian blocks | |
| - Auto switch calibration flags (fix aspect ratio and elements of distortion matrix if needed) | |
| - Auto detect when calibration is done by using several criteria | |
| - Auto capture of static patterns (user doesn't need press any keys to capture frame, just don't move pattern for a second) | |
| Supported patterns: | |
| - Black-white chessboard | |
| - Asymmetrical circle pattern | |
| - Dual asymmetrical circle pattern | |
| - chAruco (chessboard with Aruco markers) | |
| - Symmetrical circle pattern | |
| Description of parameters | |
| ------ | |
| Application has two groups of parameters: primary (passed through command line) and advances (passed through XML file). | |
| ### Primary parameters: | |
| All of this parameters are passed to application through a command line. | |
| -[parameter]=[default value]: description | |
| - -v=[filename]: get video from filename, default input -- camera with id=0 | |
| - -ci=[0]: get video from camera with specified id | |
| - -flip=[false]: vertical flip of input frames | |
| - -t=[circles]: pattern for calibration (circles, chessboard, dualCircles, chAruco, symcircles) | |
| - -sz=[16.3]: distance between two nearest centers of circles or squares on calibration board | |
| - -dst=[295] distance between white and black parts of dualCircles pattern | |
| - -w=[width]: width of pattern (in corners or circles) | |
| - -h=[height]: height of pattern (in corners or circles) | |
| - -of=[camParams.xml]: output file name | |
| - -ft=[true]: auto tuning of calibration flags | |
| - -vis=[grid]: captured boards visualization (grid, window) | |
| - -d=[0.8]: delay between captures in seconds | |
| - -pf=[defaultConfig.xml]: advanced application parameters file | |
| - -force_reopen=[false]: Forcefully reopen camera in case of errors. Can be helpful for ip cameras with unstable connection. | |
| - -save_frames=[false]: Save frames that contribute to final calibration | |
| - -zoom=[1]: Zoom factor applied to the preview image | |
| ### Advanced parameters: | |
| By default values of advanced parameters are stored in defaultConfig.xml | |
| @code{.xml} | |
| <?xml version="1.0"?> | |
| <opencv_storage> | |
| <charuco_dict>0</charuco_dict> | |
| <charuco_square_length>200</charuco_square_length> | |
| <charuco_marker_size>100</charuco_marker_size> | |
| <calibration_step>1</calibration_step> | |
| <max_frames_num>30</max_frames_num> | |
| <min_frames_num>10</min_frames_num> | |
| <solver_eps>1e-7</solver_eps> | |
| <solver_max_iters>30</solver_max_iters> | |
| <fast_solver>0</fast_solver> | |
| <frame_filter_conv_param>0.1</frame_filter_conv_param> | |
| <camera_resolution>1280 720</camera_resolution> | |
| </opencv_storage> | |
| @endcode | |
| - *charuco_dict*: name of special dictionary, which has been used for generation of chAruco pattern | |
| - *charuco_square_length*: size of square on chAruco board (in pixels) | |
| - *charuco_marker_size*: size of Aruco markers on chAruco board (in pixels) | |
| - *calibration_step*: interval in frames between launches of @ref cv::calibrateCamera | |
| - *max_frames_num*: if number of frames for calibration is greater then this value frames filter starts working. | |
| After filtration size of calibration dataset is equals to *max_frames_num* | |
| - *min_frames_num*: if number of frames is greater then this value turns on auto flags tuning, undistorted view and quality evaluation | |
| - *solver_eps*: precision of Levenberg-Marquardt solver in @ref cv::calibrateCamera | |
| - *solver_max_iters*: iterations limit of solver | |
| - *fast_solver*: if this value is nonzero and Lapack is found QR decomposition is used instead of SVD in solver. | |
| QR faster than SVD, but potentially less precise | |
| - *frame_filter_conv_param*: parameter which used in linear convolution of bicriterial frames filter | |
| - *camera_resolution*: resolution of camera which is used for calibration | |
| **Note:** *charuco_dict*, *charuco_square_length* and *charuco_marker_size* are used for chAruco pattern generation | |
| (see Aruco module description for details: [Aruco tutorials](https://github.com/opencv/opencv_contrib/tree/4.x/modules/aruco/tutorials)) | |
| Default chAruco pattern: | |
|  | |
| Dual circles pattern | |
| ------ | |
| To make this pattern you need standard OpenCV circles pattern and binary inverted one. | |
| Place two patterns on one plane in order when all horizontal lines of circles in one pattern are | |
| continuations of similar lines in another. | |
| Measure distance between patterns as shown at picture below pass it as **dst** command line parameter. Also measure distance between centers of nearest circles and pass | |
| this value as **sz** command line parameter. | |
|  | |
| This pattern is very sensitive to quality of production and measurements. | |
| Data filtration | |
| ------ | |
| When size of calibration dataset is greater then *max_frames_num* starts working | |
| data filter. It tries to remove "bad" frames from dataset. Filter removes the frame | |
| on which \f$loss\_function\f$ takes maximum. | |
| \f[loss\_function(i)=\alpha RMS(i)+(1-\alpha)reducedGridQuality(i)\f] | |
| **RMS** is an average re-projection error calculated for frame *i*, **reducedGridQuality** | |
| is scene coverage quality evaluation without frame *i*. \f$\alpha\f$ is equals to | |
| **frame_filter_conv_param**. | |
| Calibration process | |
| ------ | |
| To start calibration just run application. Place pattern ahead the camera and fixate pattern in some pose. | |
| After that wait for capturing (will be shown message like "Frame #i captured"). | |
| Current focal distance and re-projection error will be shown at the main screen. Move pattern to the next position and repeat procedure. Try to cover image plane | |
| uniformly and don't show pattern on sharp angles to the image plane. | |
|  | |
| If calibration seems to be successful (confidence intervals and average re-projection | |
| error are small, frame coverage quality and number of pattern views are big enough) | |
| application will show a message like on screen below. | |
|  | |
| Hot keys: | |
| - Esc -- exit application | |
| - s -- save current data to XML file | |
| - r -- delete last frame | |
| - d -- delete all frames | |
| - u -- enable/disable applying of undistortion | |
| - v -- switch visualization mode | |
| Results | |
| ------ | |
| As result you will get camera parameters and confidence intervals for them. | |
| Example of output XML file: | |
| @code{.xml} | |
| <?xml version="1.0"?> | |
| <opencv_storage> | |
| <calibrationDate>"Thu 07 Apr 2016 04:23:03 PM MSK"</calibrationDate> | |
| <framesCount>21</framesCount> | |
| <cameraResolution> | |
| 1280 720</cameraResolution> | |
| <cameraMatrix type_id="opencv-matrix"> | |
| <rows>3</rows> | |
| <cols>3</cols> | |
| <dt>d</dt> | |
| <data> | |
| 1.2519588293098975e+03 0. 6.6684948780852471e+02 0. | |
| 1.2519588293098975e+03 3.6298123112613683e+02 0. 0. 1.</data></cameraMatrix> | |
| <cameraMatrix_std_dev type_id="opencv-matrix"> | |
| <rows>4</rows> | |
| <cols>1</cols> | |
| <dt>d</dt> | |
| <data> | |
| 0. 1.2887048808572649e+01 2.8536856683866230e+00 | |
| 2.8341737483430314e+00</data></cameraMatrix_std_dev> | |
| <dist_coeffs type_id="opencv-matrix"> | |
| <rows>1</rows> | |
| <cols>5</cols> | |
| <dt>d</dt> | |
| <data> | |
| 1.3569117181595716e-01 -8.2513063822554633e-01 0. 0. | |
| 1.6412101575010554e+00</data></dist_coeffs> | |
| <dist_coeffs_std_dev type_id="opencv-matrix"> | |
| <rows>5</rows> | |
| <cols>1</cols> | |
| <dt>d</dt> | |
| <data> | |
| 1.5570675523402111e-02 8.7229075437543435e-02 0. 0. | |
| 1.8382427901856876e-01</data></dist_coeffs_std_dev> | |
| <avg_reprojection_error>4.2691743074130178e-01</avg_reprojection_error> | |
| </opencv_storage> | |