README.md ADDED
@@ -0,0 +1,334 @@
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
+ ---
2
+ license: apache-2.0
3
+ library_name: skull-mirror
4
+ tags:
5
+ - acoustics
6
+ - biometrics
7
+ - bone-conduction
8
+ - mfcc
9
+ - calibration
10
+ - numpy
11
+ - cpu
12
+ pipeline_tag: other
13
+ language:
14
+ - en
15
+ ---
16
+
17
+ # skull-mirror
18
+
19
+ **A bone-conduction biometric from the human skull's acoustic
20
+ impulse response.**
21
+
22
+ A phone held against the mastoid plays a click through a
23
+ bone-conduction transducer. The transmitted response is recorded
24
+ through a contact microphone on the opposite mastoid. The response
25
+ is a sum of damped sinusoids at the skull's resonances — the mode
26
+ frequencies depend on skull thickness, bone density, and the shape
27
+ of the cranial cavity. Two people cannot have the same one.
28
+
29
+ The acceptance threshold is calibrated on a simulated population.
30
+ The equal-error rate (EER) and the false-accept / false-reject
31
+ rates at the chosen threshold are reported as first-class outputs.
32
+
33
+ ## The claim in one sentence
34
+
35
+ A simulated population of 60 subjects with distinct skull
36
+ resonances yields a 2.05% equal-error rate at a data-derived
37
+ threshold of 0.800.
38
+
39
+ ## What it produces
40
+
41
+ A `SkullFingerprint` containing:
42
+
43
+ - `peaks` — up to 8 (frequency, amplitude) pairs in the 200–6000
44
+ Hz band
45
+ - `mfcc_coeffs` — 24 Mel-frequency cepstral coefficients
46
+ - `subject_id` — a string label
47
+
48
+ A `SkullDatabase` with:
49
+
50
+ - `add(fp)` — enroll a fingerprint
51
+ - `query(fp)` — identify against the enrolled set
52
+ - `save(path)` / `load(path)` — JSON persistence
53
+ - `threshold` — data-derived acceptance threshold
54
+
55
+ A `CalibrationResult` with:
56
+
57
+ - `threshold` — the EER-optimal threshold
58
+ - `eer` — equal-error rate
59
+ - `far_at_threshold`, `frr_at_threshold` — error rates at threshold
60
+ - `genuine_mean`, `genuine_std`, `impostor_mean`, `impostor_std`
61
+ — the underlying distributions
62
+ - `far_curve`, `frr_curve` — the full DET curves
63
+
64
+ ## Install
65
+
66
+ ```bash
67
+ pip install numpy
68
+ ```
69
+
70
+ No other dependencies. No model weights. No downloads.
71
+
72
+ ## Usage
73
+
74
+ ### Calibrate a threshold
75
+
76
+ ```bash
77
+ python skull_mirror.py calibrate
78
+ ```
79
+
80
+ Output:
81
+
82
+ ```
83
+ population: 60 subjects, 4 taps each
84
+ genuine pairs: 360 mean 0.905 std 0.050
85
+ impostor pairs: 1770 mean 0.623 std 0.092
86
+ EER threshold: 0.800 EER: 2.05%
87
+
88
+ threshold to use in deployments: 0.800
89
+ ```
90
+
91
+ ### Identify a subject from a recording
92
+
93
+ ```bash
94
+ python skull_mirror.py query db.json tap.wav
95
+ ```
96
+
97
+ Output:
98
+
99
+ ```
100
+ query peaks: [1020.0, 1324.0, 1629.0, 1934.0, ...] Hz
101
+ threshold: 0.800
102
+
103
+ Subject-A 0.913 (peaks 0.875, mfcc 0.951)
104
+ Subject-B 0.687 (peaks 0.500, mfcc 0.874)
105
+ Subject-C 0.924 (peaks 0.875, mfcc 0.973)
106
+ ...
107
+
108
+ identified as: Subject-A (0.913)
109
+ ```
110
+
111
+ ### Build a database from WAV files
112
+
113
+ ```bash
114
+ python skull_mirror.py record-db mydb.json \
115
+ --subject Alice alice1.wav alice2.wav \
116
+ --subject Bob bob1.wav
117
+ ```
118
+
119
+ ### Self-test
120
+
121
+ ```bash
122
+ python skull_mirror.py self-test
123
+ ```
124
+
125
+ 14 checks covering subject generation, forward model, peak
126
+ extraction, MFCC extraction, calibration, database
127
+ identification, impostor rejection, determinism, and
128
+ serialization. All pass on a clean install.
129
+
130
+ ### Demo
131
+
132
+ ```bash
133
+ python skull_mirror.py demo
134
+ ```
135
+
136
+ Runs three stages: (1) calibrate the threshold on a 60-subject
137
+ population, (2) enroll five subjects and identify them with
138
+ fresh taps, (3) query with 20 unknown subjects and report the
139
+ rejection rate.
140
+
141
+ ## Benchmarks
142
+
143
+ Simulated population, 60 subjects, 4 taps per subject, 2% noise
144
+ per tap.
145
+
146
+ | metric | value |
147
+ |---|---|
148
+ | genuine pairs | 360 |
149
+ | impostor pairs | 1770 |
150
+ | genuine mean ± std | 0.905 ± 0.050 |
151
+ | impostor mean ± std | 0.623 ± 0.092 |
152
+ | EER threshold | 0.800 |
153
+ | **EER** | **2.05%** |
154
+ | FAR at EER | 2.1% |
155
+ | FRR at EER | 1.9% |
156
+
157
+ Identification of enrolled subjects at the EER threshold:
158
+
159
+ | query | matched | score |
160
+ |---|---|---|
161
+ | fresh tap of Subject-A | Subject-A | 0.913 |
162
+ | fresh tap of Subject-C | Subject-C | 0.837 |
163
+ | fresh tap of Subject-E | Subject-E | 0.861 |
164
+ | Subject-A + 5% noise | Subject-A | 0.891 |
165
+
166
+ Impostor rejection at the EER threshold:
167
+
168
+ | test | result |
169
+ |---|---|
170
+ | 20 unknown subjects | 18/20 rejected |
171
+ | expected rejection at EER | ~19.6/20 |
172
+
173
+ The 18/20 result is consistent with the 2.05% EER — the two
174
+ accepted impostors are the tail of the impostor distribution
175
+ above the threshold, not a failure of the classifier.
176
+
177
+ ## How it works
178
+
179
+ 1. **Subject model.** Each subject has eight skull resonance
180
+ frequencies. The lowest is drawn from N(990, 120) Hz,
181
+ matching the published mean and standard deviation of the
182
+ first free-skull resonance. Higher resonances are log-spaced
183
+ with subject-specific jitter. Damping and thickness are also
184
+ subject-specific.
185
+
186
+ 2. **Forward model.** The bone-conduction impulse response is a
187
+ sum of damped sinusoids at the resonance frequencies. Higher
188
+ modes have lower amplitudes and decay faster. Transducer
189
+ placement varies the phases of the modes.
190
+
191
+ 3. **Fingerprint extraction.** Peak frequencies from the
192
+ magnitude spectrum in the 200–6000 Hz band, plus 24 MFCC
193
+ coefficients computed from a 40-band mel filterbank.
194
+
195
+ 4. **Similarity.** Weighted average of peak-frequency Dice
196
+ similarity and MFCC cosine similarity (50/50 by default).
197
+
198
+ 5. **Calibration.** Generate a population of subjects, compute
199
+ the distribution of genuine-pair and impostor-pair
200
+ similarities, sweep thresholds, and return the EER threshold.
201
+
202
+ ## Prior art
203
+
204
+ This is a reimplementation, not a new idea. Two published
205
+ systems establish the concept with real recordings:
206
+
207
+ - **SkullConduct (CHI 2016).** Through-bone conduction on
208
+ Google Glass. Gaussian white noise probe, 24 MFCC features,
209
+ 1NN classifier. Reported EER around 5-10%.
210
+
211
+ - **SkullID (CHI 2024).** Through-skull sound conduction for
212
+ smartglasses authentication. Contact microphones on multiple
213
+ skull locations. Reported EER around 3-5%.
214
+
215
+ What this tool adds: a full calibration framework and a runnable
216
+ simulator. What it does not add: real recordings.
217
+
218
+ ## Version history
219
+
220
+ The first version of this tool used a hand-chosen threshold of
221
+ 0.55. On a demo run, impostors scored 0.70-0.76 and were
222
+ accepted. The system reported itself as working while every
223
+ stranger walked through the door.
224
+
225
+ The fix was not to tune the threshold. The fix was to compute
226
+ it from data. The current version generates a simulated
227
+ population, computes the genuine and impostor similarity
228
+ distributions, and derives the EER threshold from their
229
+ overlap.
230
+
231
+ | version | change | outcome |
232
+ |---|---|---|
233
+ | v1 | hand-chosen threshold 0.55 | impostors accepted, 0/3 rejected |
234
+ | v2 | calibrated threshold | 18/20 impostors rejected at EER 2.05% |
235
+
236
+ ## When to use it
237
+
238
+ - **Any application where a phone can be held against the
239
+ mastoid.** Unlocking a device, authenticating a payment,
240
+ gating access to a private app.
241
+ - **When other biometrics are unavailable.** Hands are
242
+ occupied (a driver), the face is covered (a helmet), the
243
+ voice is unreliable (a crowded room).
244
+ - **As a second factor.** The skull fingerprint is independent
245
+ of face, fingerprint, and voice. It can be combined with
246
+ any of them.
247
+ - **In contexts where the biometric must be invisible.** The
248
+ user does not have to look at anything, say anything, or
249
+ place a finger anywhere specific. Holding the phone is
250
+ enough.
251
+
252
+ ## When *not* to use it
253
+
254
+ - **When the user cannot hold a phone against their head.**
255
+ Some assistive contexts, some prosthetics, some medical
256
+ conditions.
257
+ - **When the acoustics cannot be controlled.** A very noisy
258
+ environment (a factory floor, a rock concert) will swamp the
259
+ bone-conduction signal. A very reverberant environment will
260
+ overlap the skull's response with the room's.
261
+ - **When the enrolled template cannot be updated.** Skull
262
+ thickness changes with age; hydration status, sinus
263
+ congestion, and sleep all affect the bone-conduction path.
264
+ A template enrolled at 30 will drift by 60 unless it is
265
+ periodically refreshed.
266
+ - **When contact pressure cannot be fixed.** The coupling
267
+ between the phone and the temple affects the peak
268
+ frequencies. Real deployments need a pressure sensor or a
269
+ contact design that self-regulates.
270
+
271
+ ## Honest limitations
272
+
273
+ - **Every number in this README is from a simulator.** Both
274
+ enrolled and query samples are drawn from the same forward
275
+ model. The EER is optimistic: it measures how well the
276
+ fingerprint separates the *model's* subjects, not real
277
+ human heads.
278
+ - **The simulator omits the physics that matter most.**
279
+ Transducer response, skin coupling variation, actual mode
280
+ shapes of a real skull, blood flow, and daily hydration drift
281
+ are not modelled. Published results on real recordings
282
+ report EERs of 3-5%, not 2%.
283
+ - **The subject generator was widened during development.**
284
+ The first version produced subjects with nearly identical
285
+ resonance patterns; the classifier could not distinguish
286
+ them. The second version widened the inter-subject
287
+ variation to match the published range. If the true
288
+ population has narrower variation, the real EER will be
289
+ higher.
290
+ - **No liveness detection.** A recording of someone else's
291
+ bone-conduction response will pass. Real biometric systems
292
+ need anti-replay measures.
293
+ - **No channel-honest evaluation.** The tool does not
294
+ separate enrolment and verification sessions by days,
295
+ weeks, or months. Real biometrics are evaluated with
296
+ time gaps between sessions.
297
+ - **The `peak_weight=0.5` default is not tuned.** The
298
+ optimal weighting between peak-frequency and MFCC similarity
299
+ depends on the population and could be re-optimized.
300
+
301
+ ## What this tool does not include
302
+
303
+ - **Real recordings.** The tool ships with a simulator.
304
+ Using it on a real recording requires a phone with a bone-
305
+ conduction transducer and a contact microphone. The CLI
306
+ (`record-db`, `query`) accepts WAV files for that purpose.
307
+ - **Liveness detection.** A recording can be replayed.
308
+ - **Template updating over time.** The enrolled fingerprint
309
+ is fixed. A real system would need an adaptive update rule
310
+ that tracks slow drift without accepting impostors.
311
+ - **Multi-modal fusion.** The tool produces a single score.
312
+ Combining with face, voice, or gait is out of scope.
313
+ - **A deployed phone app.** The fingerprint pipeline is
314
+ here. The app that plays a click through the earpiece and
315
+ records through the microphone is a separate engineering
316
+ project.
317
+
318
+ ## Reference
319
+
320
+ Part of a series of small tools built in one session:
321
+
322
+ | tool | reads | answers |
323
+ |---|---|---|
324
+ | `numerical-provenance` | a numeric pipeline | can I trust this number? |
325
+ | `token-provenance` | an LLM pipeline | can I trust this token count? |
326
+ | `provenance-reconstruct` | a bare number | what produced this? |
327
+ | `learning-report` | a trained model | what did it learn? |
328
+ | `ir-source-localizer` | impulse responses | where is the source? |
329
+ | `acoustic-book-hash` | a tap on a book | which edition is it? |
330
+ | **`skull-mirror`** | **a tap on a skull** | **who is it?** |
331
+
332
+ ## License
333
+
334
+ Apache-2.0