Cholesterol Concentration Predictor β€” ANN Model

Model summary

This model repository accompanies research on the use of artificial neural networks (ANNs) and an Au@CeOβ‚‚ (gold–cerium oxide) nanozyme-based colourimetric sensor for cholesterol estimation. The corresponding Gradio application enables users to compare ANN predictions with a linear-regression baseline using mean RGB colour measurements.

Publication: Govindharaj, P., Alungal, N., Emerald, C. S. and Kannan, S. (2026). Au@CeOβ‚‚ nanozyme based smart colourimetric sensor for cholesterol: A neural network powered point of care solution model. Biochemical Engineering Journal, 225, 109908. DOI: 10.1016/j.bej.2025.109908.

Links: Associated publication Β· Interactive Gradio Space Β· Researcher's website

Intended uses

  • Research and educational exploration of ANN-based colourimetric regression.
  • Comparing predictions under different neural-network configurations in the companion application, to the extent that their trained files are available in its archive.
  • Reproducing and examining the method when the original measurement protocol, preprocessing and training artefacts are available.

Not intended for diagnosis, screening, monitoring, treatment selection or any other clinical use. This repository does not establish medical-device validation.

Data and features

The application uses three numerical inputs: mean red, green and blue intensities. Each is expected to be in the range 0–255. These values should come from appropriately collected colourimetric measurements, rather than arbitrary photographs or uncontrolled lighting conditions.

The application code uses this transform for inference:

x = [[R / 256.0, G / 256.0, B / 256.0]]

Architecture and model coverage

The application describes a 3–N–1 feedforward ANN: three RGB features, one hidden layer of variable width N, and a single output. Approximately 2,500 trained model configurations, varying activation function, random seed and hidden-neuron count.

The Gradio Space locates its model files under:

Models.zip
└── Models/
    └── <activation>/
        └── <seed>/
            └── model_<number_of_hidden_neurons>.keras

Configuration from the repository name or the publication's best-performing model can be inferred.

Baseline and evaluation

The application implements a linear-regression comparator using normalised RGB inputs:

linear_raw = (
    1.9221 * (R / 256.0)
    - 1.3817 * (G / 256.0)
    + 1.4058 * (B / 256.0)
    - 0.1318
)
linear_mM = max(0.0, linear_raw) * 50.0

The publication's abstract reports:

Measure Study-reported value
Best validation MSE 0.0577 (hard shrink, 13 hidden neurons)
Lowest training MSE 0.0637 (SELU, 7 hidden neurons)
Median training MSE 0.0896
Median validation MSE 0.0769
Reported colourimetric linearity range 0–50 mM

How to use

Recommended: open the companion application, supply calibrated mean RGB values, choose an available activation, seed and hidden-neuron count, and compare the outputs.

For programmatic use: examine the repository's actual files and loading instructions for the specific saved Keras model. The general TensorFlow/Keras pattern is:

import numpy as np
import tensorflow as tf

model = tf.keras.models.load_model("path/to/model.keras", compile=False)
x = np.array([[R / 256.0, G / 256.0, B / 256.0]])
raw = float(np.asarray(model.predict(x, verbose=0)).reshape(-1)[0])
predicted_mM = max(0.0, raw) * 50.0

Replace path/to/model.keras with the downloaded model path.

Limitations, safety and licence

  • Experimental results depend on sample preparation, sensor chemistry, calibration, lighting, camera characteristics, image processing and domain shift.
  • Predictions are not calibrated confidence intervals and should not be used as medical measurements.
  • Clamping negative outputs to zero does not correct model error or guarantee validity.
  • The publication reports a range of 0–50 mM; extrapolation and comparisons outside its study conditions require separate validation.

Citation

Govindharaj, P., Alungal, N., Emerald, C. S. and Kannan, S. (2026). Au@CeOβ‚‚ nanozyme based smart colourimetric sensor for cholesterol: A neural network powered point of care solution model. Biochemical Engineering Journal, 225, 109908. https://doi.org/10.1016/j.bej.2025.109908

Contact: Caxton Emerald S β€” professional website Β· ORCID

Downloads last month
30,117
Inference Providers NEW
This model isn't deployed by any Inference Provider. πŸ™‹ Ask for provider support

Space using CaxtonEmeraldS/CholesterolConcentrationPredictor 1