Instructions to use CaxtonEmeraldS/CholesterolConcentrationPredictor with libraries, inference providers, notebooks, and local apps. Follow these links to get started.
- Libraries
- Keras
How to use CaxtonEmeraldS/CholesterolConcentrationPredictor with Keras:
# !pip install -U keras tensorflow huggingface_hub # Keras needs TensorFlow installed to read "hf://" paths, so the tensorflow backend is selected here; # "jax" and "torch" also work for computation once TensorFlow is installed. import os os.environ["KERAS_BACKEND"] = "tensorflow" import keras model = keras.saving.load_model("hf://CaxtonEmeraldS/CholesterolConcentrationPredictor") - Notebooks
- Google Colab
- Kaggle
File size: 5,136 Bytes
029d259 | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 | ---
license: cc-by-nc-sa-4.0
language:
- en
library_name: keras
tags:
- regression
- tensorflow
- keras
- colourimetric-sensing
- biosensing
- cholesterol
- research-demo
---
# Cholesterol Concentration Predictor — ANN Model
## Model summary
This model repository accompanies research on the use of artificial neural networks (ANNs) and an Au@CeO₂ (gold–cerium oxide) nanozyme-based colourimetric sensor for cholesterol estimation. The corresponding **Gradio application** enables users to compare ANN predictions with a linear-regression baseline using mean RGB colour measurements.
**Publication:** Govindharaj, P., Alungal, N., Emerald, C. S. and Kannan, S. (2026). *Au@CeO₂ nanozyme based smart colourimetric sensor for cholesterol: A neural network powered point of care solution model.* **Biochemical Engineering Journal**, **225**, 109908. DOI: [10.1016/j.bej.2025.109908](https://doi.org/10.1016/j.bej.2025.109908).
**Links:** [Associated publication](https://doi.org/10.1016/j.bej.2025.109908) · [Interactive Gradio Space](https://huggingface.co/spaces/CaxtonEmeraldS/CholesterolConcentrationPredictor) · [Researcher's website](https://caxtonemerald-s.github.io)
## Intended uses
- Research and educational exploration of ANN-based colourimetric regression.
- Comparing predictions under different neural-network configurations **in the companion application**, to the extent that their trained files are available in its archive.
- Reproducing and examining the method when the original measurement protocol, preprocessing and training artefacts are available.
**Not intended for diagnosis, screening, monitoring, treatment selection or any other clinical use.** This repository does not establish medical-device validation.
## Data and features
The application uses **three numerical inputs**: mean red, green and blue intensities. Each is expected to be in the range **0–255**. These values should come from appropriately collected colourimetric measurements, rather than arbitrary photographs or uncontrolled lighting conditions.
The application code uses this transform for inference:
```python
x = [[R / 256.0, G / 256.0, B / 256.0]]
```
## Architecture and model coverage
The application describes a **3–N–1** feedforward ANN: three RGB features, one hidden layer of variable width `N`, and a single output. Approximately **2,500 trained model configurations**, varying activation function, random seed and hidden-neuron count.
The Gradio Space locates its model files under:
```text
Models.zip
└── Models/
└── <activation>/
└── <seed>/
└── model_<number_of_hidden_neurons>.keras
```
Configuration from the repository name or the publication's best-performing model can be inferred.
## Baseline and evaluation
The application implements a linear-regression comparator using normalised RGB inputs:
```python
linear_raw = (
1.9221 * (R / 256.0)
- 1.3817 * (G / 256.0)
+ 1.4058 * (B / 256.0)
- 0.1318
)
linear_mM = max(0.0, linear_raw) * 50.0
```
The publication's abstract reports:
| Measure | Study-reported value |
|---|---:|
| Best validation MSE | 0.0577 (hard shrink, 13 hidden neurons) |
| Lowest training MSE | 0.0637 (SELU, 7 hidden neurons) |
| Median training MSE | 0.0896 |
| Median validation MSE | 0.0769 |
| Reported colourimetric linearity range | 0–50 mM |
## How to use
**Recommended:** open the [companion application](https://huggingface.co/spaces/CaxtonEmeraldS/CholesterolConcentrationPredictor), supply calibrated mean RGB values, choose an available activation, seed and hidden-neuron count, and compare the outputs.
**For programmatic use:** examine the repository's actual files and loading instructions for the specific saved Keras model. The general TensorFlow/Keras pattern is:
```python
import numpy as np
import tensorflow as tf
model = tf.keras.models.load_model("path/to/model.keras", compile=False)
x = np.array([[R / 256.0, G / 256.0, B / 256.0]])
raw = float(np.asarray(model.predict(x, verbose=0)).reshape(-1)[0])
predicted_mM = max(0.0, raw) * 50.0
```
Replace `path/to/model.keras` with the downloaded model path.
## Limitations, safety and licence
- Experimental results depend on sample preparation, sensor chemistry, calibration, lighting, camera characteristics, image processing and domain shift.
- Predictions are **not** calibrated confidence intervals and should not be used as medical measurements.
- Clamping negative outputs to zero does not correct model error or guarantee validity.
- The publication reports a range of 0–50 mM; extrapolation and comparisons outside its study conditions require separate validation.
## Citation
Govindharaj, P., Alungal, N., Emerald, C. S. and Kannan, S. (2026). Au@CeO₂ nanozyme based smart colourimetric sensor for cholesterol: A neural network powered point of care solution model. *Biochemical Engineering Journal*, 225, 109908. https://doi.org/10.1016/j.bej.2025.109908
**Contact:** [Caxton Emerald S — professional website](https://caxtonemerald-s.github.io) · [ORCID](https://orcid.org/0000-0002-7763-3987) |