Feature Extraction
Transformers
Safetensors
PyTorch
English
manas2
eeg
neuroscience
foundation-model
masked-autoencoder
representation-learning
custom_code
Instructions to use MannasAI/pratibha-2 with libraries, inference providers, notebooks, and local apps. Follow these links to get started.
- Libraries
- Transformers
How to use MannasAI/pratibha-2 with Transformers:
# Use a pipeline as a high-level helper from transformers import pipeline pipe = pipeline("feature-extraction", model="MannasAI/pratibha-2", trust_remote_code=True)# pip install -U transformers accelerate # Load model directly from transformers import AutoModel model = AutoModel.from_pretrained("MannasAI/pratibha-2", trust_remote_code=True, device_map="auto") - Notebooks
- Google Colab
- Kaggle
|
Download README.md from MannasAI/pratibha-2: direct link, hf CLI and curl.
- Browser
- Download file 5.7 kB
-
https://huggingface.co/MannasAI/pratibha-2/resolve/main/README.md
- Command line
-
hf download hf://MannasAI/pratibha-2/README.md
-
curl -L -o README.md https://huggingface.co/MannasAI/pratibha-2/resolve/main/README.md
5.7 kB
| library_name: transformers | |
| pipeline_tag: feature-extraction | |
| license: apache-2.0 | |
| language: | |
| - en | |
| tags: | |
| - eeg | |
| - neuroscience | |
| - foundation-model | |
| - masked-autoencoder | |
| - representation-learning | |
| - pytorch | |
| - custom_code | |
| # PRATIBHA-2, formerly known as "MANAS-2" | |
| PRATIBHA-2 (also called MANAS-2) is a transformer-based foundation model for EEG representation learning, developed by [MannasAI](https://huggingface.co/MannasAI). It combines **Raw-Band Hybrid (RBH)** masked autoencoding with **Constrained Reconstruction (ConRec)** to learn temporal and spectral features from EEG. | |
| ## Model Details | |
| PRATIBHA-2 has **92.8M parameters**, 22 transformer layers, and 512-dimensional embeddings. It processes EEG sampled at **200 Hz** using one-second patches with a 0.1-second overlap and spatiotemporal positional encoding. Channel count and signal length can vary. | |
| During pretraining, RBH uses waveform and spectral reconstruction, while ConRec regularizes local RMS-energy continuity in reconstructed waveforms. Pretraining uses unlabeled clinical EEG from internal sources, TUH EEG, and I-CARE. This release contains the encoder for feature extraction and fine-tuning. | |
| **Paper:** [MANAS-2: Constrained Reconstruction for EEG Foundation Models](https://arxiv.org/abs/2609.13717) | |
| ## Uses | |
| Install the dependencies: | |
| ```bash | |
| pip install "torch>=2.2" "transformers>=4.57,<5" "safetensors>=0.4" | |
| ``` | |
| Extract embeddings using the included electrode-position lookup: | |
| ```python | |
| import torch | |
| from transformers import AutoModel | |
| model = AutoModel.from_pretrained( | |
| "MannasAI/MANAS-2", trust_remote_code=True, | |
| ).eval() | |
| # Example: 10 seconds of EEG at 200 Hz. | |
| electrode_names = ["Fz", "Cz", "Pz"] | |
| eeg = torch.randn(1, 3, 2000) # [batch, channels, samples] | |
| eeg = (eeg - eeg.mean(-1, keepdim=True)) / ( | |
| eeg.std(-1, keepdim=True, correction=1) + 1e-6 | |
| ) | |
| positions = model.get_channel_positions(electrode_names) | |
| positions = positions.unsqueeze(0).expand(eeg.size(0), -1, -1) | |
| with torch.inference_mode(): | |
| features = model(eeg, positions) # [1, 11, 3, 512] | |
| embedding = features.mean(dim=(1, 2)) # [1, 512] | |
| ``` | |
| For real EEG, filter and resample to 200 Hz, then normalize each channel within each window as above. Electrode names must match the signal's channel order; the lookup returns coordinates in centimeters. The model expects preprocessed inputs and returns **[batch, patches, channels, 512]** features. | |
| ## Metrics | |
| PRATIBHA-2 has been evaluated using [NeuralBench](https://github.com/facebookresearch/neuroai/tree/main/neuralbench-repo). It outperforms all open source FMs currently included in the benchmark (as of 15/11/26), with an average rank across 34 tasks (NeuralBench's "core" tasks set) of 3.94. | |
| **Average Ranks** (lower is better) | |
| | Foundation model | Average rank ↓ | | |
| |---|---:| | |
| | **Pratibha-2** | **3.94** | | |
| | LaBraM | 4.94 | | |
| | REVE | 5.00 | | |
| | LUNA | 6.47 | | |
| | CBraMod | 6.76 | | |
| | BENDR | 10.71 | | |
| | BIOT | 12.32 | | |
| **Per-task performance** | |
| | Category | Task | Metric | Pratibha-2 | | |
| |---|---|---|---:| | |
| | Cognitive | Image | Top-5 accuracy (%) | 86.12 ± 1.64 | | |
| | Cognitive | Sentence | Top-5 accuracy (%) | 12.69 ± 0.60 | | |
| | Cognitive | Typing | Balanced accuracy (%) | 4.66 ± 0.27 | | |
| | Cognitive | Word | Top-5 accuracy (%) | 16.59 ± 0.83 | | |
| | BCI | c-VEP | Balanced accuracy (%) | 87.06 ± 0.73 | | |
| | BCI | Mental imagery | Balanced accuracy (%) | 27.54 ± 1.27 | | |
| | BCI | Motor execution | Balanced accuracy (%) | 55.12 ± 2.40 | | |
| | BCI | Motor imagery | Balanced accuracy (%) | 66.81 ± 0.20 | | |
| | BCI | P300 | Balanced accuracy (%) | 66.00 ± 0.38 | | |
| | BCI | SSVEP | Balanced accuracy (%) | 92.96 ± 0.71 | | |
| | Evoked Responses | Audiovisual | Balanced accuracy (%) | 43.69 ± 6.19 | | |
| | Evoked Responses | ERN | Balanced accuracy (%) | 78.14 ± 3.26 | | |
| | Evoked Responses | LRP | Balanced accuracy (%) | 78.69 ± 1.13 | | |
| | Evoked Responses | MMN | Balanced accuracy (%) | 58.05 ± 0.55 | | |
| | Evoked Responses | N170 | Balanced accuracy (%) | 71.35 ± 2.82 | | |
| | Evoked Responses | N2pc | Balanced accuracy (%) | 63.96 ± 0.67 | | |
| | Evoked Responses | N400 | Balanced accuracy (%) | 64.83 ± 1.52 | | |
| | Clinical | Clinical event | Macro F1 | 0.562 ± 0.024 | | |
| | Clinical | Dementia | Balanced accuracy (%) | 42.34 ± 6.03 | | |
| | Clinical | Depression | Balanced accuracy (%) | 88.37 ± 1.18 | | |
| | Clinical | Parkinson’s | Balanced accuracy (%) | 69.96 ± 0.49 | | |
| | Clinical | Pathology | Balanced accuracy (%) | 79.43 ± 0.79 | | |
| | Clinical | Schizophrenia | Balanced accuracy (%) | 67.27 ± 4.51 | | |
| | Clinical | Seizure | Balanced accuracy (%) | 70.89 ± 0.39 | | |
| | Internal State | **Emotion** | **Balanced accuracy (%)** | **30.21 ± 0.18** | | |
| | Internal State | Mental arithmetic | Balanced accuracy (%) | 73.54 ± 2.63 | | |
| | Internal State | Workload | Balanced accuracy (%) | 70.09 ± 1.80 | | |
| | Sleep | Sleep arousal | Balanced accuracy (%) | 58.02 ± 0.72 | | |
| | Sleep | Sleep stage | Balanced accuracy (%) | 74.23 ± 0.12 | | |
| | Phenotyping | Age | Pearson R | 0.706 ± 0.012 | | |
| | Phenotyping | Psychopathology | Pearson R | 0.089 ± 0.015 | | |
| | Phenotyping | Sex | Balanced accuracy (%) | 91.91 ± 0.38 | | |
| | Misc | Artifact | Macro F1 | 0.550 ± 0.006 | | |
| | Misc | Reaction time | Pearson R | 0.562 ± 0.004 | | |
| ## License | |
| Model weights and code are released under [Apache-2.0](LICENSE). | |
| ## Citation | |
| ```bibtex | |
| @misc{kulkarni2026PRATIBHA2, | |
| title={MANAS-2: Constrained Reconstruction for EEG Foundation Models}, | |
| author={Arvasu Kulkarni and Aditya Ray Mishra and Mahir Jain and Parshva Runwal and Lakshya Saini and Siddharth Panwar and Sandeep Singh}, | |
| year={2026}, | |
| eprint={2609.13717}, | |
| archivePrefix={arXiv}, | |
| primaryClass={cs.AI}, | |
| url={https://arxiv.org/abs/2609.13717} | |
| } | |
| ``` | |