alpha-m1 / README.md
absint0o's picture
Release Alpha M1 weights and model card
da72046
|
Raw History Blame Contribute Delete
10.4 kB
metadata
license: apache-2.0
base_model: Cactus-Compute/needle3
library_name: cactus-compute
pipeline_tag: text-generation
language:
  - en
tags:
  - function-calling
  - tool-calling
  - iot
  - machine-control
  - weight-space-programming
  - edge-ai

Alpha M1

Lab & Interactive Report: https://wsplabs.org/#/models/alpha-m1

Alpha M1 is a pair of small on-device tool-calling models from WSP Labs, derived from Needle 3 by Cactus Compute. Naming follows the WSP Labs scheme: Alpha is the compact on-device line, M is the Machine Control domain and 1 is the generation.

The weights were not retrained. We edited 25 FP16 scalars in the confidence head, which is 0.0000207% of the 20L parameters, with zero gradient steps. The packed 2-bit and 4-bit weights, the tokenizer and the file layout are byte-identical to the base archive, and the file size is unchanged (35,335,380 bytes for 20L, 28,942,164 bytes for 16L).

What changes is calibration. The base model often produces the right tool call but reports a confidence that is too low, so the runtime's confidence gate suppresses it. Alpha M1 raises the confidence of those calls and leaves the calls themselves alone.

Variants

File Depth Parameters Bytes SHA-256 (Alpha M1) SHA-256 (base Needle 3)
alpha-m1-20l.cact 20L 121M 35,335,380 879c5a606f298549f60406b09c7d4eeaa1f384dea47289a9a75bc4d5a86bf1d4 c9d915eca282ed42d1a09b143b592adb4cc6744ffe2d294adf5cfc5548170c38
alpha-m1-16l.cact 16L 98M 28,942,164 6aef29228d364032f0c4851ac20c9619c11c3f33d2ab5813f559ffe811048164 3ca3b4096b13d31c82cfaf1dd00bd08d151e3f92c1511bfc590dd97c36619094

Quickstart

pip install cactus-compute
import json
import cactus

tools = [{
    "name": "set_light_level",
    "description": "Sets the light output of a lighting zone as a percentage.",
    "parameters": {"type": "object", "properties": {
        "light_zone": {"type": "string", "description": "Name of the lighting zone."},
        "level_percent": {"type": "integer", "description": "Brightness level from 0 to 100."}},
        "required": ["light_zone", "level_percent"]},
}]

agent = cactus.Needle(
    weights="alpha-m1-20l.cact",
    tools=json.dumps(tools),
    system="You are a model that can do function calling with the following functions\n",
    auto_date=False,
)
agent.reset()
out = agent.complete("Dim the cellar lights to 45 percent.")
calls = out["function_calls"] or out["suppressed_calls"]
if out["confidence"] >= 0.40:      # production gate
    print(calls)
agent.close()

cactus.Needle applies the runtime's own default confidence gate and, when it suppresses a call, returns it in suppressed_calls. The snippet above reads both lists and applies the production gate of 0.40 itself, which is the rule used in the benchmark tables below.

How the edit works

Needle 3 stores most weights as codebook-quantized blocks. Small additive edits to such weights vanish when they are rounded back to the codebook, whereas exact-precision FP16 scalars are unaffected by that rounding. Alpha M1 changes only 25 such exact-precision scalars (50 bytes), solved in closed form.

The solver sees only synthetic calibration data that was checked against the sealed hash index. A candidate is accepted only if it passes a no-regression check on held-in data.

Evaluation protocol

  • Seven sealed suites (5,676 items per model): Cactus Official Envs, Mobile Actions, DroidCall, BFCL v4, DSTC8, SNIPS and an IoT simulator.
  • Paired, item by item: the same items go through both archives with the same runner, one pass, and reset() before every query.
  • Exact McNemar test on discordant pairs, 95% Wilson intervals. No multiplicity correction is applied across depths, suites and gates, so treat borderline p-values accordingly.
  • The frozen 20L archive was evaluated once. The 16L result was evaluated once after its gates were fixed on synthetic data only.
  • Gates: 0.0_forced acts on every returned call whatever the confidence; 0.0_raw acts only on calls the runtime released; 0.1 and 0.4 require that confidence.

Results: Alpha M1 20L (121M)

Gate 0.10 (default):

Suite n Base Alpha M1 Delta Gains / losses p (one-sided)
Cactus Official Envs 192 77.6% 77.1% -0.52 pp 2 / 3 0.8125
Mobile Actions 961 39.2% 48.2% +8.95 pp 86 / 0 1.3e-26
DroidCall 200 33.0% 34.0% +1.00 pp 2 / 0 0.25
BFCL v4 1000 42.8% 44.6% +1.80 pp 36 / 18 0.0099
DSTC8 (extraction) 1813 6.9% 8.1% +1.21 pp 22 / 0 2.4e-07
SNIPS (extraction) 1400 4.2% 4.6% +0.43 pp 6 / 0 0.0156
IoT simulator 110 19.1% 19.1% +0.00 pp 1 / 1 0.75

Gate 0.40 (production):

Suite n Base Alpha M1 Delta Gains / losses p (one-sided)
Cactus Official Envs 192 57.8% 65.6% +7.81 pp 22 / 7 0.0041
Mobile Actions 961 16.3% 19.6% +3.23 pp 57 / 26 4.4e-04
DroidCall 200 23.5% 22.0% -1.50 pp 5 / 8 0.8666
BFCL v4 1000 36.2% 37.5% +1.30 pp 20 / 7 0.0096
DSTC8 (extraction) 1813 2.5% 5.2% +2.70 pp 51 / 2 1.6e-13
SNIPS (extraction) 1400 1.2% 1.5% +0.29 pp 8 / 4 0.1938
IoT simulator 110 10.0% 11.8% +1.82 pp 2 / 0 0.25

Extraction micro-F1:

Gate Suite Base F1 Alpha M1 F1 Relative
0.1 DSTC8 (extraction) 0.1505 0.1937 +28.8%
0.1 SNIPS (extraction) 0.1169 0.1524 +30.4%
0.4 DSTC8 (extraction) 0.0448 0.0942 +110.2%
0.4 SNIPS (extraction) 0.0235 0.0346 +47.3%

BFCL v4 AST accuracy at gate 0.10 rises by 25.5% relative (20.5% to 25.8%).

Results: Alpha M1 16L (98M)

Gate 0.40:

Suite n Base Alpha M1 Delta Gains / losses p (one-sided)
Cactus Official Envs 192 67.7% 66.7% -1.04 pp 12 / 14 0.7214
Mobile Actions 961 17.2% 20.6% +3.43 pp 54 / 21 8.8e-05
DroidCall 200 19.5% 19.5% +0.00 pp 4 / 4 0.6367
BFCL v4 1000 35.7% 35.8% +0.10 pp 19 / 18 0.5
DSTC8 (extraction) 1813 4.1% 6.1% +1.99 pp 39 / 3 2.8e-09
SNIPS (extraction) 1400 2.1% 2.2% +0.07 pp 4 / 3 0.5
IoT simulator 110 11.8% 13.6% +1.82 pp 2 / 0 0.25

Gate 0.10:

Suite n Base Alpha M1 Delta Gains / losses p (one-sided)
Cactus Official Envs 192 69.8% 69.8% +0.00 pp 1 / 1 0.75
Mobile Actions 961 39.5% 39.8% +0.21 pp 4 / 2 0.3438
DroidCall 200 24.0% 24.0% +0.00 pp 0 / 0 1
BFCL v4 1000 38.5% 37.7% -0.80 pp 4 / 12 0.9894
DSTC8 (extraction) 1813 7.6% 7.8% +0.28 pp 5 / 0 0.0312
SNIPS (extraction) 1400 3.4% 3.3% -0.07 pp 0 / 1 1
IoT simulator 110 15.5% 16.4% +0.91 pp 1 / 0 0.5

Where Alpha M1 wins

  • Mobile Actions, 20L, gate 0.10: +8.95 pp (39.2% to 48.2%), 86 gains and 0 losses, exact McNemar one-sided p = 1.3e-26.
  • Extraction F1, 20L, gate 0.10: +28.8% relative on DSTC8 and +30.4% on SNIPS. On DSTC8 accuracy, 22 gains against 0 losses (p = 2.4e-07); at gate 0.40, 51 against 2 (p = 1.6e-13).
  • Cactus Official Envs, 20L, gate 0.40: +7.81 pp (22 gains, 7 losses, one-sided p = 0.0041).
  • 16L carries the effect too: Mobile Actions at gate 0.40 improves by +3.43 pp with 54 gains and 21 losses.

Where it does not help

  • Forced answers do not change. At 0.0_forced every suite has zero gains and zero losses on both depths. The edit changes the confidence value, not the tokens of the call, so when you act on every call regardless of confidence, Alpha M1 and Needle 3 answer identically. If you do not use a confidence gate, you gain nothing.
  • Lower irrelevance accuracy at the default gate. On BFCL v4 irrelevance at gate 0.10, 20L drops from 92.9% to 87.1% (0 gains, 18 losses, two-sided p = 7.6e-06). Raising confidence also raises the chance that an off-topic request clears the gate. At gate 0.40 irrelevance accuracy is unchanged (99.0%). The 16L file loses irrelevance accuracy too: 85.1% to 82.2% at gate 0.10 and 98.4% to 95.1% at gate 0.40.
  • No measurable change on some suites. DroidCall and the IoT simulator are within noise at every gate for 20L; the 20L Cactus Official Envs result at gate 0.10 is slightly negative and not significant.
  • It cannot add capacity that is missing. On the 4L (29M) rung the strict zero-break gate rejected every candidate, so no patch was shipped. When we relaxed the gate to accept a net gain, irrelevance accuracy rose from 74.1% to 93.2% while positive calls collapsed: Mobile Actions fell from 14.2% to 3.0% and BFCL AST from 5.4% to 0.6%. That patch was not released. The 8L rung also ended as a byte-identical no-op.

Safety notes

Alpha M1 is a calibration edit of a small model. It is not a safety system.

  • The runtime's negation validator blocks explicit negations such as "Do NOT open the high-pressure vent valve HP-3; only check its status." in both models (confidence 0.43 and 0.44; the block does not come from confidence).
  • A paraphrase, "Under no circumstances should vent valve HP-3 be opened.", passes that validator and both models emit open_vent_valve.
  • For anything that moves hardware, keep an independent interlock and a confirmation step outside the model.

Interactive examples

The project site at https://wsplabs.org runs six freshly authored scenarios through both archives, with measured outputs. They were screened against the sealed benchmarks (no overlap) and picked from a few hundred candidates to show the gate mechanism, so treat them as illustrations; the tables above are the evidence.

Verify the files

sha256sum -c SHA256SUMS.txt

Each Alpha M1 file differs from its base archive in 25 FP16 scalars only.

License and attribution

Apache-2.0. Alpha M1 is a derivative of Needle 3 by Cactus Compute (Cactus-Compute/needle3), also Apache-2.0. See LICENSE and NOTICE. The Cactus runtime is a separate package and is not included.