Datasets:
ConveyorAD
A multi-view, PTP-synchronised video dataset for visual anomaly detection on a moving conveyor belt.
Each passage is one physical part crossing the belt, filmed at the same instants by three hardware-synchronised cameras (IEEE 1588 / PTP). Passages are recorded under controlled nuisance conditions (reduced lighting, increased belt speed, distractor objects), so that robustness can be measured.
- Code, splits, evaluation harness and reference methods: https://github.com/AlexLeclerc102/ConveyorAD
- Full documentation of the data (ground-truth formats, known issues, benchmark design): the
repository's
README.md.
At a glance
| Object | 1 industrial connector insert (56 Γ 23 Γ 30 mm, ten contacts) |
| Passages | 46 (14 normal, 32 defective) |
| Views (passage Γ camera) | 138 |
| Frames | 4 629 (1 447 normal, 3 182 from defective passages) |
| Cameras | 3 Γ Basler ace U acA2440-20gc, PTP-synchronised, 15 fps |
| Resolution | 2456 Γ 1842, JPEG |
| Defective parts | 7 part_ids over 6 physical objects (7 and 8 are the same connector) |
| Defect classes | broken terminal slot, missing screw, ink mark (7 type ids, 2β8) |
| Ground truth | per-frame object mask, per-frame anomaly mask (binary and typed), COCO polygons |
| Size | ~9.6 GB |
| Condition | Normal passages | Defective passages |
|---|---|---|
nominal |
9 | 23 |
half_closed_shutter |
0 | 2 |
closed_shutter |
2 | 4 |
inc_speed (1.55Γ belt speed) |
1 | 2 |
with_background_objects |
2 | 1 |
There are no normal passages under half_closed_shutter: passage-level AUROC is undefined
for that condition, frame-level AUROC is not.
Layout
connector/
βββ OK/{condition}/{passage_id}/{camera_id}/
βββ NOK/{condition}/{part_id}/{passage_id}/{camera_id}/
βββ {frame}.jpg # RGB image
βββ {frame}.png # anomaly mask, 0 / 100 (defective passages only)
βββ {frame}_type.png # anomaly mask, pixel = type id (defective passages only)
βββ {frame}_bg.png # object mask, 0 / 255 (semi-automatic, SAM 2)
βββ annotations.json # COCO polygons for this view
βββ mask/{frame}.jpg # visualisation overlay, not ground truth
geometry/
βββ calibration.json # fitted three-camera calibration
βββ poses.json # fitted part pose in every frame
βββ README.md # conventions of both files
{frame} is a global frame counter shared by the three cameras: the same index in two
cameras is the same instant. Join views on it, not on position in the sequence.
Two properties matter for any benchmark built on this data:
- A frame from a defective passage is not necessarily an anomalous frame. The defect may
face away from that camera at that instant. Frame labels come from the masks; passage
labels come from the
OK/NOKfolder. - Splits must be grouped by
part_id, never by passage: the same physical defect is recorded several times, under several conditions.
Download
hf download ALeclerc/ConveyorAD --repo-type dataset --local-dir conveyorad_data
export CONVEYORAD_ROOT=$PWD/conveyorad_data
Geometry
No calibration was recorded and the rig no longer exists. geometry/ holds a calibration
and per-frame part poses recovered from the belt and from a CAD model close to the part;
they are fits, not measurements. See geometry/README.md and the paper's appendix.
License
CC-BY-4.0. The code in the GitHub repository is under Apache-2.0.
Citation
@misc{conveyorad2026,
title = {ConveyorAD: Multi-View Video Anomaly Detection on a Moving Conveyor Belt},
author = {Leclerc, Alexandre},
year = {2026},
url = {https://github.com/AlexLeclerc102/ConveyorAD}
}
- Downloads last month
- 42