CaptureData commited on
Commit
0bd23de
·
verified ·
1 Parent(s): c2d37f3

Update README.md

Browse files
Files changed (1) hide show
  1. README.md +101 -34
README.md CHANGED
@@ -1,6 +1,5 @@
1
-
2
  ---
3
- pretty_name: "CAPTURE Dataset: GPDAS Prototype Data Acquisition"
4
  viewer: false
5
  tags:
6
  - video
@@ -12,65 +11,133 @@ tags:
12
 
13
  # CAPTURE Dataset: GPDAS Prototype Data Acquisition
14
 
 
 
 
 
15
  ## Overview
16
 
17
- This dataset contains five recording sessions collected on November 13, 2026, using an instrumented colonoscopy prototype and a benchtop training model.
18
 
19
- The recordings combine internal endoscope video, external camera views, sensor measurements, and timing information. Together, these data provide an initial foundation for studying operator interactions, evaluating data synchronization, and developing methods for vision-based analysis and machine learning.
20
 
21
- This is an early prototype dataset intended primarily for research and development rather than clinical evaluation.
22
 
23
  [Browse All Dataset Files](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/tree/main)
24
 
25
- ## Dataset Contents
26
-
27
- The collection includes:
28
 
29
- - **Internal endoscope video:** Intraluminal recordings captured through the Ambu aBox system.
30
- - **External high-resolution video:** Basler camera recordings documenting external instrument and operator activity.
31
- - **Additional camera views:** Two Logitech webcams providing supplementary perspectives.
32
- - **Sensor measurements:** Recorded instrument signals and demonstration sensor channels.
33
- - **Timing and synchronization data:** Frame timestamps, sensor logs, and optical synchronization events used to relate the recordings across devices.
 
34
 
35
- The dataset preserves original recordings where available, alongside converted video files intended to simplify viewing and preliminary analysis.
36
 
37
- ## Recommended Starting Point
38
 
39
- **Session 3 is the recommended starting point.**
 
 
 
 
 
 
40
 
41
- It contains a completed 24-minute recording with both optical synchronization markers, allowing the internal endoscope video to be paired with the external recordings.
42
-
43
- Session 2 is a short setup and synchronization test. Sessions 1, 4, and 5 are partial recordings with recovered webcam footage.
44
 
45
  - [Browse Session 3 Files](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/tree/main/Session3_11_13_26)
46
  - [View Session 3 Basler MP4](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/blob/main/Encoding_Examples_Session3/Session3_Basler_H264.mp4)
47
 
48
- ## Working With the Data
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
49
 
50
- **Basler camera:** Original recordings are stored as raw image data (`basler0.raw`), with frame timing provided in `basler0_frames.csv`. The accompanying recording metadata describes the image format and dimensions. A converted MP4 is provided as a convenient viewing example.
51
 
52
- **Logitech cameras:** Corrected MP4 recordings are provided for easier playback. The accompanying frame timing files support approximate alignment with other recordings. Sessions 2 and 3 use `camera*_frames.csv`, while Sessions 1, 4, and 5 use `camera*_frame_map.csv`.
53
 
54
- **Endoscope video and sensor data:** The internal aBox video can be compared with external camera recordings and logged sensor measurements. Session 3 has a verified video pairing using two optical synchronization markers. Pairings for the remaining sessions are provisional.
55
 
56
- ## Current Limitations
57
 
58
- This collection represents an early stage of prototype development and includes several limitations relevant to downstream analysis:
59
 
60
- - Cross-camera synchronization is approximate, and frame timestamps do not necessarily represent exact exposure times.
61
- - Some sessions are incomplete, and recovered recordings may contain interruptions.
62
- - Partial Basler recordings may end with an incomplete image frame.
63
- - Sensor data include demonstration channels and should not be interpreted as fully calibrated instrument measurements.
 
64
  - Calibrated insertion depth and clinical annotations are not included.
65
 
66
- Researchers should review the timing metadata and recording status before using individual sessions for synchronized or frame-level analysis.
67
 
68
- ## Intended Research Applications
69
 
70
- The dataset may support preliminary investigation of multimodal data acquisition, endoscope motion analysis, video synchronization, sensor-video alignment, and the development of computer vision and machine learning workflows.
71
 
72
- It is not intended as a clinically validated dataset or as a source of ground-truth operator actions.
73
 
74
  ## License and Usage
75
 
76
- License information is pending. No public reuse license has been assigned.
 
 
1
  ---
2
+ pretty_name: "CAPTURE Dataset: GPDAS Prototype Data Acquisition - November 13, 2026"
3
  viewer: false
4
  tags:
5
  - video
 
11
 
12
  # CAPTURE Dataset: GPDAS Prototype Data Acquisition
13
 
14
+ **Collection Date:** November 13, 2026
15
+ **Environment:** Benchtop colonoscopy model
16
+ **System:** GPDAS Instrumented Data Acquisition Prototype
17
+
18
  ## Overview
19
 
20
+ This dataset contains five recording sessions collected using the GPDAS prototype, an instrumented colonoscopy testbed developed to capture synchronized video and operator actions.
21
 
22
+ The recordings combine intraluminal video, external camera views, sensor measurements, and timing information to support research in computer vision, sensor integration, and machine learning.
23
 
24
+ This collection represents an early stage of prototype development and is intended for research and development rather than clinical evaluation.
25
 
26
  [Browse All Dataset Files](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/tree/main)
27
 
28
+ ## Recorded Data
 
 
29
 
30
+ | Source | Description |
31
+ |---|---|
32
+ | **Ambu aBox** | Internal endoscope video showing the simulated intraluminal environment |
33
+ | **Basler0** | High-resolution external camera recording supporting observation of instrument activity |
34
+ | **Logitech Cameras (2)** | Supplementary external views of the instrument and procedure |
35
+ | **Sensor and Timing Logs** | Recorded sensor channels, frame timestamps, and synchronization information |
36
 
37
+ Sensor channels include demonstration measurements and should not be interpreted as fully calibrated operator-action data.
38
 
39
+ ## Recording Sessions
40
 
41
+ | Session | Description |
42
+ |---|---|
43
+ | **Session 1** | Partial recording with recovered webcam footage |
44
+ | **Session 2** | Short setup and synchronization test |
45
+ | **Session 3** | Completed 24-minute recording with two verified optical synchronization markers |
46
+ | **Session 4** | Partial recording with recovered webcam footage |
47
+ | **Session 5** | Partial recording with recovered webcam footage |
48
 
49
+ **Session 3 is the recommended starting point** for researchers evaluating the available recordings and synchronization data. Its aBox video pairing was verified using both optical markers. Pairings for the remaining sessions are provisional.
 
 
50
 
51
  - [Browse Session 3 Files](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/tree/main/Session3_11_13_26)
52
  - [View Session 3 Basler MP4](https://huggingface.co/datasets/CaptureData/capture_11_13_26_dataset/blob/main/Encoding_Examples_Session3/Session3_Basler_H264.mp4)
53
 
54
+ ## Accessing the Recordings
55
+
56
+ Original camera recordings and associated metadata are preserved where available. Encoded MP4 examples are provided for easier inspection without requiring specialized raw-video processing tools.
57
+
58
+ ### Encoding Examples
59
+
60
+ - **Basler MP4:** Converted from the original raw Bayer image stream for conventional video playback.
61
+ - **Logitech MP4:** Recovered and corrected webcam recordings, with available frame timing information preserved separately.
62
+ - **Ambu aBox:** Internal endoscope recordings provided for comparison with external views.
63
+
64
+ Encoded video is intended for viewing and preliminary analysis. Researchers performing synchronization or frame-level processing should use the original recordings and associated timing metadata.
65
+
66
+ ### Working with Raw Video
67
+
68
+ **Basler Camera**
69
+
70
+ The Basler camera records uncompressed image frames in a raw Bayer format. Unlike an MP4, the raw file does not contain a conventional video header or playback timing information.
71
+
72
+ | File | Purpose |
73
+ |---|---|
74
+ | `basler0.raw` | Original raw image frames |
75
+ | `basler0_frames.csv` | Frame timing information |
76
+ | Recording metadata (`.json`) | Image dimensions, pixel format, and acquisition parameters |
77
+
78
+ The raw recording can be previewed or converted using FFmpeg, provided the correct image dimensions and pixel format are specified.
79
+
80
+ **Example: Preview BayerRG8 video**
81
+
82
+ ```bash
83
+ ffplay -f rawvideo \
84
+ -pixel_format bayer_rggb8 \
85
+ -video_size WIDTHxHEIGHT \
86
+ -framerate FPS \
87
+ basler0.raw
88
+ ```
89
+
90
+ **Example: Convert to H.264 MP4**
91
+
92
+ ```bash
93
+ ffmpeg -f rawvideo \
94
+ -pixel_format bayer_rggb8 \
95
+ -video_size WIDTHxHEIGHT \
96
+ -framerate FPS \
97
+ -i basler0.raw \
98
+ -vf format=yuv420p \
99
+ -c:v libx264 -crf 18 \
100
+ basler0_converted.mp4
101
+ ```
102
+
103
+ Replace `WIDTH`, `HEIGHT`, and `FPS` with the recording parameters. These examples assume tightly packed BayerRG8 frames without row padding; consult the recording metadata before processing.
104
+
105
+ The frame rate supplied during conversion determines playback speed. **For synchronization and temporal analysis, use `basler0_frames.csv` rather than the timestamps generated by the converted MP4.**
106
+
107
+ **Logitech Cameras**
108
+
109
+ Webcam recordings are provided as corrected MP4 files. Each reconstructed clip begins at its own first available frame.
110
+
111
+ - Sessions 2 and 3 use `camera*_frames.csv`.
112
+ - Sessions 1, 4, and 5 use `camera*_frame_map.csv`.
113
+
114
+ The timing files support approximate alignment between camera streams. Cross-camera exposure timing is not guaranteed to be frame-accurate.
115
 
116
+ **Endoscope Video and Sensor Data**
117
 
118
+ The internal aBox recordings can be examined alongside external camera views and the logged sensor measurements.
119
 
120
+ Session 3 has a verified aBox video pairing using two optical synchronization markers. Other pairings remain provisional.
121
 
122
+ ## Data Quality and Limitations
123
 
124
+ This collection includes preliminary and partially recovered recordings. The following limitations apply:
125
 
126
+ - Sessions 1, 4, and 5 are incomplete and include recovered webcam footage.
127
+ - Partial Basler recordings may terminate with an incomplete image frame.
128
+ - Cross-camera synchronization is approximate.
129
+ - Frame timestamps do not necessarily represent exact exposure times.
130
+ - Sensor channels include demonstration measurements and are not fully calibrated.
131
  - Calibrated insertion depth and clinical annotations are not included.
132
 
133
+ Researchers should review individual session metadata before performing synchronized or frame-level analysis.
134
 
135
+ ## Research Applications
136
 
137
+ The dataset supports preliminary investigation of multimodal data acquisition, video synchronization, optical motion tracking, sensor-video alignment, and machine learning workflows.
138
 
139
+ The recordings represent prototype research data and do not constitute a clinically validated or fully calibrated ground-truth dataset.
140
 
141
  ## License and Usage
142
 
143
+ License information is pending. No public reuse license has been assigned.