ecgdig / data /README.md
RyanIRL's picture
ecgdig: data
a6bc474 verified
|
Raw History Blame Contribute Delete
2.59 kB

ecgdig dataset

Recover 12-lead ECG voltage time series from images of printed ECG pages.

Layout

train.csv                 one row per training record: id, fs, sig_len
train/<id>/<id>.csv       ground-truth signal table for that record
train/<id>/<id>-v*.{png,jpg}   nine images of the same printed record
test.csv                  one row per test record and lead:
                          id, lead, fs, number_of_rows
test/<id>.jpg             ONE image per test record (condition varies)
sample_submission.csv     valid all-zeros submission (the format contract)

Records

A record is one 12-lead ECG acquisition, 10 seconds long, sampled at fs Hz (fs is one of 250, 256, 500, 512, 1000, 1025; sig_len = fs * 10). Each printed page uses the standard 3x4 layout plus a lead II rhythm strip at 25 mm/s and 10 mm/mV: lead II is visible for the full 10 s; every other lead is visible for one 2.5 s column (I, II, III during 0 to 2.5 s, aVR, aVL, aVF during 2.5 to 5 s, V1, V2, V3 during 5 to 7.5 s, V4, V5, V6 during 7.5 to 10 s).

Signal tables (train//.csv)

sig_len rows, twelve columns I, II, III, aVR, aVL, aVF, V1..V6, values in millivolts. Each lead holds numbers only inside its visible window and NaN outside it; lead II is fully populated. The visible windows are what a submission must reconstruct for test records.

Image conditions

Every training record carries nine images of the same printed page:

  • v1 clean digital render of the page (PNG)
  • v2 color print, scanned in color (JPEG)
  • v3 color print, scanned in black and white (PNG)
  • v4 phone photo of the printed page (JPEG)
  • v5 phone photo of the page shown on a laptop screen (JPEG)
  • v6 phone photo of a stained and soaked printout (JPEG)
  • v7 phone photo of a heavily damaged printout (JPEG)
  • v8 color scan of a mold-degraded printout (JPEG)
  • v9 black and white scan of a mold-degraded printout (JPEG)

Each test record provides exactly ONE image (JPEG), drawn from these same conditions; the condition is not labeled. The pages carry printed header furniture (an id string, age, sex, a date, sometimes a QR code); it is page decoration, and the rules forbid using it to try to identify source recordings.

Submission format

CSV with header id,value; id = {record}_{row}_{lead} covering, for every test record, fs * 10 rows for lead II and floor(fs * 2.5) rows for each other lead (number_of_rows in test.csv is authoritative). value is the predicted voltage in mV at that sample. Every expected id exactly once; finite values only.