Datasets:
Download data/README.md from Emulated-Inc/ecgdig: direct link, hf CLI and curl.
- Browser
- Download file 2.59 kB
-
https://huggingface.co/datasets/Emulated-Inc/ecgdig/resolve/main/data/README.md
- Command line
-
hf download hf://datasets/Emulated-Inc/ecgdig/data/README.md
-
curl -L -o README.md https://huggingface.co/datasets/Emulated-Inc/ecgdig/resolve/main/data/README.md
ecgdig dataset
Recover 12-lead ECG voltage time series from images of printed ECG pages.
Layout
train.csv one row per training record: id, fs, sig_len
train/<id>/<id>.csv ground-truth signal table for that record
train/<id>/<id>-v*.{png,jpg} nine images of the same printed record
test.csv one row per test record and lead:
id, lead, fs, number_of_rows
test/<id>.jpg ONE image per test record (condition varies)
sample_submission.csv valid all-zeros submission (the format contract)
Records
A record is one 12-lead ECG acquisition, 10 seconds long, sampled at fs
Hz (fs is one of 250, 256, 500, 512, 1000, 1025; sig_len = fs * 10).
Each printed page uses the standard 3x4 layout plus a lead II rhythm
strip at 25 mm/s and 10 mm/mV: lead II is visible for the full 10 s;
every other lead is visible for one 2.5 s column (I, II, III during
0 to 2.5 s, aVR, aVL, aVF during 2.5 to 5 s, V1, V2, V3 during 5 to
7.5 s, V4, V5, V6 during 7.5 to 10 s).
Signal tables (train//.csv)
sig_len rows, twelve columns I, II, III, aVR, aVL, aVF, V1..V6, values
in millivolts. Each lead holds numbers only inside its visible window and
NaN outside it; lead II is fully populated. The visible windows are what a
submission must reconstruct for test records.
Image conditions
Every training record carries nine images of the same printed page:
v1clean digital render of the page (PNG)v2color print, scanned in color (JPEG)v3color print, scanned in black and white (PNG)v4phone photo of the printed page (JPEG)v5phone photo of the page shown on a laptop screen (JPEG)v6phone photo of a stained and soaked printout (JPEG)v7phone photo of a heavily damaged printout (JPEG)v8color scan of a mold-degraded printout (JPEG)v9black and white scan of a mold-degraded printout (JPEG)
Each test record provides exactly ONE image (JPEG), drawn from these same conditions; the condition is not labeled. The pages carry printed header furniture (an id string, age, sex, a date, sometimes a QR code); it is page decoration, and the rules forbid using it to try to identify source recordings.
Submission format
CSV with header id,value; id = {record}_{row}_{lead} covering, for
every test record, fs * 10 rows for lead II and floor(fs * 2.5) rows
for each other lead (number_of_rows in test.csv is authoritative).
value is the predicted voltage in mV at that sample. Every expected id
exactly once; finite values only.