Download reports/reference_dataset.md from MstJeon410/cooling_project: direct link, hf CLI and curl.
- Browser
- Download file 5.13 kB
-
https://huggingface.co/datasets/MstJeon410/cooling_project/resolve/main/reports/reference_dataset.md
- Command line
-
hf download hf://datasets/MstJeon410/cooling_project/reports/reference_dataset.md
-
curl -L -o reference_dataset.md https://huggingface.co/datasets/MstJeon410/cooling_project/resolve/main/reports/reference_dataset.md
Stage 4: reference data
Status: no new reference data. The official solver is not available on this box.
- Carbon's reference is OpenFOAM v2512
chtMultiRegionSimpleFoam, imageopencfd/openfoam-default@sha256:33fb575a…. - Docker cannot start containers on this machine, and OpenFOAM is not installed natively.
- Following cooling.md ("If the official solver is unavailable, document the limitation and do not claim reference accuracy"):
- no reference cases were generated;
- no analytical prediction is used anywhere as a label;
- every accuracy figure in Stages 1–7 is measured against Carbon's own published solver outputs (below) and nothing else.
- The choice of how to get a solver is open with the owner:
- (A) install ESI OpenFOAM v2512 natively and prove it reproduces TRAIN and verify rows;
- (B) solve on the Docker machine.
Reference data that exists (Carbon's official solver outputs)
| Set | Rows | Mesh | Use so far |
|---|---|---|---|
TRAIN 1.8 rows 0–399 (cooling-dev-train-1p8-v1, sha 326cb301; batches cold-plate-train-v1 92 + -remaining-v1 308) |
400 | counted r = 2, 72,000 cells, 2,000 iterations | fitting, always scored out-of-fold (2-fold thermal, 10-fold hydraulic) |
| TRAIN 1.8 rows 400–457 | 58 | graded-hotspot-v1 r = 2√2 (the exam's mesh) | as above |
Verify set (kits/cooling/verify_set.json, Carbon's pinned truths, same image) |
6 | [A] the exam's mesh (the file does not state the mesh) | never fitted; read after each candidate was built (see "Independence") |
- Solver records on the counted rows: wall time 146–1,496 s per case (median 292 s) on Carbon's machine.
- Convergence checks per record: energy balance ≤ 1e-6 relative, mass imbalance ≤ 1e-9, last iteration change ≤ 1e-6 K. All 458 rows have status OK.
- The 58 graded rows carry inputs, outputs and options only: no checks, no peak position.
Coverage of the experiment groups in cooling.md by the existing data
| Group | Existing rows | Comment |
|---|---|---|
| Normal conditions | 458 TRAIN | spread over the box; rows 400–457 lean toward narrow, intense hotspots (mean σ 1.89 vs 2.50 mm, ratio 2.27 vs 1.95) |
| Hydraulic boundary conditions (flow near its bounds, entrance-heavy) | 153 rows with entrance share > 0.129; 46 within 5 % of a flow bound (21 low, 25 high) | no paired flow sweeps |
| Narrow hotspots (σ ≤ 2 mm) | 142 | σ ≥ 1.5 mm in TRAIN; none below |
| Extreme hotspot intensity (ratio ≥ 2.5) | 115 | ratio ≤ 3.0 |
| Combined extremes (narrow and intense) | 46 | |
| Unseen geometry combinations | verify-01 (aspect 0.56) and verify-05 (x⁺ 1.13) | 2 cases |
| Out of the training range | 6 verify designs, 0.01–0.08 of a span outside the box | too few for statistics |
| Controlled one-factor sweeps (paired cases) | none | flow, load and hotspot derivatives of the reference cannot be measured from random draws |
Independence: what is and is not clean
- TRAIN: every number in Stages 1–7 is out-of-fold. Constants come from the other fold(s), and no candidate was chosen on in-sample error.
- Model structure was still chosen while looking at TRAIN CV results, so TRAIN CV is slightly optimistic, as Carbon notes for its own default model.
- Verify: never used to fit a constant, but its six errors were read for every candidate. It is therefore not a pristine hold-out. With only 6 cases it cannot detect a 0.1 K bias anyway.
- "Reserve independent validation cases before selecting formulas or fitting coefficients" is not met. No reserved set exists, because no new cases could be solved. This is the main open item for the claims in Stages 5–7.
Planned reference experiments (not run; need the solver)
All on graded-hotspot-v1 r = 2√2, the exam's truth mesh. I estimate ≈2–4 core-h per case there [A]: about 3.5× the counted mesh's cells, and the counted mesh takes 0.5–1 core-h per case.
Reproduction check, before anything else. Re-solve 6 TRAIN graded rows, 4 counted rows and the 6 verify designs. Pass condition: the solver reproduces Carbon's outputs. Bit-identical is expected with the same image. With a native install, show the differences are ≤ 0.01 K and ≤ 0.1 % Δp.
Sealed hold-out, drawn and hashed before any further fitting. About 100 cases in the groups above, seeded draw:
- normal 30;
- narrow 15;
- extreme 15;
- combined 10;
- entrance-heavy 10;
- out-of-box (+10–20 % beyond the bounds) 20.
Only read once, at Stage 9.
Controlled sweeps for the derivatives the regimes depend on, to measure the reference's S_Q, k_Q and n_Q directly:
- 4 anchor designs (hotspot-peak, outlet-peak, contested-peak, entrance-heavy);
- for each anchor, 5 levels of flow, load, hotspot ratio, width and centre: about 100 cases.
Mesh-family pairs: about 20 TRAIN counted rows re-solved on the exam's mesh. They measure the counted→graded thermal offset (+0.057 ± 0.014 K estimated in Stage 7) and the Δp offset directly, instead of inferring them from 58 non-paired rows.
None of the numbers in this plan are results.