CTS-PADC_Dataset / Readme_for_code.md
OCEAN-Lab's picture
Update Readme_for_code.md
fccfb5a verified
|
Raw History Blame Contribute Delete
2.99 kB
metadata
language:
  - en
license: cc-by-sa-4.0
task_categories:
  - time-series-forecasting
  - tabular-regression
tags:
  - photonics
  - time-stretch-adc
  - signal-processing
  - nonlinear-equalization
  - optical-communications
size_categories:
  - 100K<n<1M

Continuous-Time Photonic Time-Stretch ADC (CTS-PADC) Dataset

An open-access experimental dataset capturing real-world optoelectronic non-idealities for machine-learning-based nonlinear equalization and denoising in continuous-time photonic time-stretch ADCs.

  • Repository: OCEAN-Lab/CTS-PADC_Dataset
  • Paper: An Open Experimental Dataset for Machine Learning-Based Nonlinear Equalization and Denoising in Continuous-Time Photonic ADCs (OFC 2027)

1. Dataset Description

Photonic Time-Stretch Analog-to-Digital Converters (PTS-ADCs) overcome electronic clock-jitter limits by stretching wideband RF signals across dispersive fiber before electronic digitization ($S \approx 3$).

However, practical physical frontends suffer from:

  1. Modulator Non-linearity: Mach--Zehnder Modulator (MZM) harmonic distortions.
  2. Clock Mixing: Intermodulation spurs with the 50-MHz Mode-Locked Laser (MLL) repetition rate.
  3. Channel Skew: Filter mismatch across the 4-channel wavelength demultiplexing network.
  4. Polarization Fluctuation: Time-varying amplitude variations in standard fiber.

This dataset provides paired distorted experimental captures and ideal ground-truth waveforms to allow researchers to benchmark their own digital signal restoration algorithms (e.g., Transformers, CNNs, State-Space Models, or Volterra filters).


2. Dataset Composition

Each record contains a paired vector of 400 temporal samples digitized at an effective stretched rate of 1 GSa/s.

Partition Frequency Grid Power Levels Replications Vector Count
In-Distribution (Train/Val) 0.6–1.4 GHz (5.1 MHz step, 143 points) -20 to +14 dBm (2 dB step, 18 levels) 300 per point 772,200
Out-of-Distribution (OOD Test) 3 Unseen Frequencies (0.8, 0.9, 1.3 GHz) All 18 power levels 300 per point 16,200
Total 788,400

3. Data Schema

Field Name Type Description
S.Numbers int64 Capture index identifier
Frequencies float32 Analog input RF frequency (GHz)
Power float32 RF input power (dBm)
arcsin_results list[float] Model Input ($x$): 400 temporal samples from differential arcsine recovery
test_data list[float] Target ($y$): 400 temporal samples of the ideal stretched continuous wave
expected_recovered_freq float32 Expected fundamental frequency after stretching ($f_{\text{RF}}/S$ in GHz)

4. How to Access and Inspect the Data

Step 1: Install Dependencies

pip install datasets pandas numpy matplotlib