Pushkarrrr15151/PolyVL-tep-report-lora
Text Generation • Updated
kind string | intent string | fault_id int64 | fault_name string | severity string | question string | answer string | system string | evidence dict | reference dict |
|---|---|---|---|---|---|---|---|---|---|
report | report | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | {"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 1.23. The dominant deviations are in A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -26.2% (trend decr... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Why do you think the feed system is the most likely cause? | The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system disturbance. The key point is the temporal ordering: the initiating variable changed first and the downst... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | How serious is this anomaly? | The severity is assessed as medium. This is based on the magnitude of the sensor deviations and the confidence of the evidence; monitor the affected variables and follow the recommended action. | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Which sensors should I inspect? | Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6. | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Could the cause be something else? | Yes. The evidence supports the candidate cause but does not prove it. The uncertainty is that correlation and temporal order are supporting evidence, not proof. On-site inspection is needed to confirm the root cause. | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
grounded_qa | metrics | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | Overall anomaly score 1.234 for ANOM-T0001. LSTM autoencoder reconstruction error = 0.4975 (threshold = 0.6874, ratio = 0.72x, Normal (below limit)). CVA dynamics Q-statistic = 474.7 (threshold = 239.8, ratio = 1.98x, ALARMED). Dominant lag 4, slow drift ratio 0.37. | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | evidence_why | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | Threshold exceedance: LSTM 0.4975 vs 0.6874 (Normal (below limit)); CVA Q 474.7 vs 239.8 (ALARMED). Telemetry excursions: A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, n... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | sensor_values | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | For ANOM-T0001: A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, normal=92.830, z=+2.56, trend decreasing); Reactor_Feed_Rate -12.4% (val=104.960, normal=63.980, z=+4.06, t... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | sensors_inspect | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6. Details: A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, n... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | overview_cause | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | ANOM-T0001 is a medium anomaly in subsystem feed_system. Likely root cause: A/C feed ratio step change. The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system d... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | severity | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | Severity is medium. This is based on the sensor deviation magnitudes (A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, normal=92.830, z=+2.56, trend decreasing); Reactor_Fe... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | action | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0001
Overall anomaly score: 1.234
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68... | Direct action: Inspect the A/C feed ratio controller setpoint and the feed control valves. Target subsystem: feed_system. Safety precaution: correlation does not prove causation; verify on site. Severity: medium. | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
severity | severity | 1 | A/C feed ratio step change | medium | An anomaly was detected in the TEP. The strongest deviations are: A_C_Feed_Flow -26.2% (trend decreasing); Reactor_Pressure -11.8% (trend decreasing); Component_A_Stream6 -10.2% (trend decreasing). The anomaly score is 1.23. Use the severity rubric. What severity should this anomaly be assigned, and why? Respond with O... | {"severity": "medium", "reasoning": "The largest deviation magnitude is 10% and the temporal sequence and affected subsystem (feed_system) indicate a medium event."} | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
discrimination | discrimination | 1 | A/C feed ratio step change | medium | An anomaly was detected in the TEP. Top deviations: A_C_Feed_Flow -26.2% (trend: decreasing); Reactor_Pressure -11.8% (trend: decreasing); Component_A_Stream6 -10.2% (trend: decreasing); Reactor_Feed_Rate -12.4% (trend: decreasing). Temporal order: A_C_Feed_Flow, then Reactor_Pressure, then Component_A_Stream6. Two can... | {"root_cause": "A/C feed ratio step change", "reasoning": "A/C feed ratio step change: the initiating variable A_C_Feed_Flow decreased first, consistent with The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pres... | {
"event_id": "ANOM-T0001",
"anomaly_score": 1.234,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.7,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.8929409166199482... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
report | report | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | {"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 1.21. The dominant deviations are in A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -38.3% (trend decr... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Why do you think the feed system is the most likely cause? | The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system disturbance. The key point is the temporal ordering: the initiating variable changed first and the downst... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | How serious is this anomaly? | The severity is assessed as medium. This is based on the magnitude of the sensor deviations and the confidence of the evidence; monitor the affected variables and follow the recommended action. | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Which sensors should I inspect? | Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6. | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Could the cause be something else? | Yes. The evidence supports the candidate cause but does not prove it. The uncertainty is that correlation and temporal order are supporting evidence, not proof. On-site inspection is needed to confirm the root cause. | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
grounded_qa | metrics | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | Overall anomaly score 1.214 for ANOM-T0002. LSTM autoencoder reconstruction error = 0.5566 (threshold = 0.6874, ratio = 0.81x, Normal (below limit)). CVA dynamics Q-statistic = 711.2 (threshold = 239.8, ratio = 2.97x, ALARMED). Dominant lag 0, slow drift ratio 0.22. | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | evidence_why | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | Threshold exceedance: LSTM 0.5566 vs 0.6874 (Normal (below limit)); CVA Q 711.2 vs 239.8 (ALARMED). Telemetry excursions: A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, ... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | sensor_values | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | For ANOM-T0002: A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, normal=72.770, z=+3.55, trend decreasing); Reactor_Feed_Rate -17.9% (val=69.670, normal=87.990, z=+2.56, t... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | sensors_inspect | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6. Details: A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, ... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | overview_cause | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | ANOM-T0002 is a medium anomaly in subsystem feed_system. Likely root cause: A/C feed ratio step change. The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system d... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | severity | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | Severity is medium. This is based on the sensor deviation magnitudes (A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, normal=72.770, z=+3.55, trend decreasing); Reactor_F... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | action | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0002
Overall anomaly score: 1.214
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: dynamic mode (dynamics dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68... | Direct action: Inspect the A/C feed ratio controller setpoint and the feed control valves. Target subsystem: feed_system. Safety precaution: correlation does not prove causation; verify on site. Severity: medium. | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
severity | severity | 1 | A/C feed ratio step change | medium | An anomaly was detected in the TEP. The strongest deviations are: A_C_Feed_Flow -38.3% (trend decreasing); Reactor_Pressure -11.8% (trend decreasing); Component_A_Stream6 -5.9% (trend decreasing). The anomaly score is 1.21. Use the severity rubric. What severity should this anomaly be assigned, and why? Respond with ON... | {"severity": "medium", "reasoning": "The largest deviation magnitude is 6% and the temporal sequence and affected subsystem (feed_system) indicate a medium event."} | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
discrimination | discrimination | 1 | A/C feed ratio step change | medium | An anomaly was detected in the TEP. Top deviations: A_C_Feed_Flow -38.3% (trend: decreasing); Reactor_Pressure -11.8% (trend: decreasing); Component_A_Stream6 -5.9% (trend: decreasing); Reactor_Feed_Rate -17.9% (trend: decreasing). Temporal order: A_C_Feed_Flow, then Reactor_Pressure, then Component_A_Stream6. Two cand... | {"root_cause": "A/C feed ratio step change", "reasoning": "A/C feed ratio step change: the initiating variable A_C_Feed_Flow decreased first, consistent with The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pres... | {
"event_id": "ANOM-T0002",
"anomaly_score": 1.214,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 7.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.4493688608715288... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
report | report | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | {"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 3.49. The dominant deviations are in A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -31.5% (trend decr... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Why do you think the feed system is the most likely cause? | The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system disturbance. The key point is the temporal ordering: the initiating variable changed first and the downst... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | How serious is this anomaly? | The severity is assessed as medium. This is based on the magnitude of the sensor deviations and the confidence of the evidence; monitor the affected variables and follow the recommended action. | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Which sensors should I inspect? | Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure. | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
followup | followup_generic | 1 | A/C feed ratio step change | medium | Could the cause be something else? | Yes. The evidence supports the candidate cause but does not prove it. The uncertainty is that correlation and temporal order are supporting evidence, not proof. On-site inspection is needed to confirm the root cause. | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
grounded_qa | metrics | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | Overall anomaly score 3.489 for ANOM-T0003. LSTM autoencoder reconstruction error = 0.8805 (threshold = 0.6874, ratio = 1.28x, ALARMED). CVA dynamics Q-statistic = 143.9 (threshold = 239.8, ratio = 0.60x, Normal (below limit)). Dominant lag 2, slow drift ratio 0.52. | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | evidence_why | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | Threshold exceedance: LSTM 0.8805 vs 0.6874 (ALARMED); CVA Q 143.9 vs 239.8 (Normal (below limit)). Telemetry excursions: A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, n... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | sensor_values | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | For ANOM-T0003: A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, normal=57.550, z=+2.13, trend decreasing); Reactor_Feed_Rate -11.8% (val=113.530, normal=67.450, z=+3.64, t... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | sensors_inspect | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure. Details: A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, n... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | overview_cause | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | ANOM-T0003 is a medium anomaly in subsystem feed_system. Likely root cause: A/C feed ratio step change. The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system d... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | severity | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | Severity is medium. This is based on the sensor deviation magnitudes (A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, normal=57.550, z=+2.13, trend decreasing); Reactor_Fe... | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
grounded_qa | action | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0003
Overall anomaly score: 3.489
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: lstm_ae mode (level dynamic pattern)
- LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,... | Direct action: Inspect the A/C feed ratio controller setpoint and the feed control valves. Target subsystem: feed_system. Safety precaution: correlation does not prove causation; verify on site. Severity: medium. | You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
severity | severity | 1 | A/C feed ratio step change | medium | An anomaly was detected in the TEP. The strongest deviations are: A_C_Feed_Flow -31.5% (trend decreasing); Component_A_Stream6 -6.2% (trend decreasing); Reactor_Pressure -8.2% (trend decreasing). The anomaly score is 3.49. Use the severity rubric. What severity should this anomaly be assigned, and why? Respond with ONL... | {"severity": "medium", "reasoning": "The largest deviation magnitude is 6% and the temporal sequence and affected subsystem (feed_system) indicate a medium event."} | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
discrimination | discrimination | 1 | A/C feed ratio step change | medium | An anomaly was detected in the TEP. Top deviations: A_C_Feed_Flow -31.5% (trend: decreasing); Component_A_Stream6 -6.2% (trend: decreasing); Reactor_Pressure -8.2% (trend: decreasing); Reactor_Feed_Rate -11.8% (trend: decreasing). Temporal order: A_C_Feed_Flow, then Component_A_Stream6, then Reactor_Pressure. Two candi... | {"root_cause": "A/C feed ratio step change", "reasoning": "A/C feed ratio step change: the initiating variable A_C_Feed_Flow decreased first, consistent with The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pres... | {
"event_id": "ANOM-T0003",
"anomaly_score": 3.489,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.1,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.7836849426704513... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} | |
report | report | 1 | A/C feed ratio step change | medium | A new anomaly has been detected in the Tennessee Eastman Process.
Event ID: ANOM-T0004
Overall anomaly score: 2.849
Assessed severity level: medium (evaluated against TEP process safety limits)
Detector trigger: both mode (mixed dynamic pattern)
- LSTM Autoencoder: reconstruction error = 1.6801 (threshold = 0.6874, ra... | {"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 2.85. The dominant deviations are in A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -27.2% (trend decr... | {
"event_id": "ANOM-T0004",
"anomaly_score": 2.849,
"severity": "medium",
"pre_anomaly_context": {
"duration_minutes": 6.4,
"status": "normal"
},
"top_anomalous_sensors": [
{
"index": 0,
"name": "A_C_Feed_Flow",
"display_name": "A_C_Feed_Flow",
"error": 0.3823481300335534... | {
"name": "A/C feed ratio step change",
"subsystem": "feed_system",
"severity": "medium"
} |
Distilled root-cause analysis reports and operator diagnostic dialogues for industrial anomaly response on the Tennessee Eastman Process (TEP).
qwen2.5:32b (Apache-2.0)qwen2.5:32b using prompt grounding contracts.qwen2.5:32b)@data{rieth2017tep,
author = {Rieth, C. A. and Amsel, B. D. and Tran, R. and Maia, M. B.},
publisher = {Harvard Dataverse},
title = {{Tennessee Eastman Process Simulation Data for Anomaly Detection}},
year = {2017},
doi = {10.7910/DVN/6C3JR1}
}
@article{polyvalent2026,
title={Polyvalent: Single-Base Multi-Specialist Architecture with Dynamic Adapter Residency},
author={Polyvalent Research Team},
year={2026}
}