Dataset Viewer
Auto-converted to Parquet Duplicate
kind
string
intent
string
fault_id
int64
fault_name
string
severity
string
question
string
answer
string
system
string
evidence
dict
reference
dict
report
report
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
{"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 1.23. The dominant deviations are in A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -26.2% (trend decr...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Why do you think the feed system is the most likely cause?
The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system disturbance. The key point is the temporal ordering: the initiating variable changed first and the downst...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
How serious is this anomaly?
The severity is assessed as medium. This is based on the magnitude of the sensor deviations and the confidence of the evidence; monitor the affected variables and follow the recommended action.
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Which sensors should I inspect?
Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6.
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Could the cause be something else?
Yes. The evidence supports the candidate cause but does not prove it. The uncertainty is that correlation and temporal order are supporting evidence, not proof. On-site inspection is needed to confirm the root cause.
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
metrics
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
Overall anomaly score 1.234 for ANOM-T0001. LSTM autoencoder reconstruction error = 0.4975 (threshold = 0.6874, ratio = 0.72x, Normal (below limit)). CVA dynamics Q-statistic = 474.7 (threshold = 239.8, ratio = 1.98x, ALARMED). Dominant lag 4, slow drift ratio 0.37.
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
evidence_why
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
Threshold exceedance: LSTM 0.4975 vs 0.6874 (Normal (below limit)); CVA Q 474.7 vs 239.8 (ALARMED). Telemetry excursions: A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, n...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
sensor_values
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
For ANOM-T0001: A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, normal=92.830, z=+2.56, trend decreasing); Reactor_Feed_Rate -12.4% (val=104.960, normal=63.980, z=+4.06, t...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
sensors_inspect
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6. Details: A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, n...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
overview_cause
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
ANOM-T0001 is a medium anomaly in subsystem feed_system. Likely root cause: A/C feed ratio step change. The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system d...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
severity
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
Severity is medium. This is based on the sensor deviation magnitudes (A_C_Feed_Flow -26.2% (val=92.080, normal=99.570, z=+2.08, trend decreasing); Reactor_Pressure -11.8% (val=64.860, normal=62.730, z=+2.73, trend decreasing); Component_A_Stream6 -10.2% (val=70.390, normal=92.830, z=+2.56, trend decreasing); Reactor_Fe...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
action
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0001 Overall anomaly score: 1.234 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.4975 (threshold = 0.68...
Direct action: Inspect the A/C feed ratio controller setpoint and the feed control valves. Target subsystem: feed_system. Safety precaution: correlation does not prove causation; verify on site. Severity: medium.
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
severity
severity
1
A/C feed ratio step change
medium
An anomaly was detected in the TEP. The strongest deviations are: A_C_Feed_Flow -26.2% (trend decreasing); Reactor_Pressure -11.8% (trend decreasing); Component_A_Stream6 -10.2% (trend decreasing). The anomaly score is 1.23. Use the severity rubric. What severity should this anomaly be assigned, and why? Respond with O...
{"severity": "medium", "reasoning": "The largest deviation magnitude is 10% and the temporal sequence and affected subsystem (feed_system) indicate a medium event."}
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
discrimination
discrimination
1
A/C feed ratio step change
medium
An anomaly was detected in the TEP. Top deviations: A_C_Feed_Flow -26.2% (trend: decreasing); Reactor_Pressure -11.8% (trend: decreasing); Component_A_Stream6 -10.2% (trend: decreasing); Reactor_Feed_Rate -12.4% (trend: decreasing). Temporal order: A_C_Feed_Flow, then Reactor_Pressure, then Component_A_Stream6. Two can...
{"root_cause": "A/C feed ratio step change", "reasoning": "A/C feed ratio step change: the initiating variable A_C_Feed_Flow decreased first, consistent with The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pres...
{ "event_id": "ANOM-T0001", "anomaly_score": 1.234, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.7, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.8929409166199482...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
report
report
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
{"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 1.21. The dominant deviations are in A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -38.3% (trend decr...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Why do you think the feed system is the most likely cause?
The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system disturbance. The key point is the temporal ordering: the initiating variable changed first and the downst...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
How serious is this anomaly?
The severity is assessed as medium. This is based on the magnitude of the sensor deviations and the confidence of the evidence; monitor the affected variables and follow the recommended action.
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Which sensors should I inspect?
Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6.
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Could the cause be something else?
Yes. The evidence supports the candidate cause but does not prove it. The uncertainty is that correlation and temporal order are supporting evidence, not proof. On-site inspection is needed to confirm the root cause.
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
metrics
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
Overall anomaly score 1.214 for ANOM-T0002. LSTM autoencoder reconstruction error = 0.5566 (threshold = 0.6874, ratio = 0.81x, Normal (below limit)). CVA dynamics Q-statistic = 711.2 (threshold = 239.8, ratio = 2.97x, ALARMED). Dominant lag 0, slow drift ratio 0.22.
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
evidence_why
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
Threshold exceedance: LSTM 0.5566 vs 0.6874 (Normal (below limit)); CVA Q 711.2 vs 239.8 (ALARMED). Telemetry excursions: A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, ...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
sensor_values
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
For ANOM-T0002: A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, normal=72.770, z=+3.55, trend decreasing); Reactor_Feed_Rate -17.9% (val=69.670, normal=87.990, z=+2.56, t...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
sensors_inspect
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Reactor_Pressure, Component_A_Stream6. Details: A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, ...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
overview_cause
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
ANOM-T0002 is a medium anomaly in subsystem feed_system. Likely root cause: A/C feed ratio step change. The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system d...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
severity
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
Severity is medium. This is based on the sensor deviation magnitudes (A_C_Feed_Flow -38.3% (val=86.400, normal=88.270, z=+2.74, trend decreasing); Reactor_Pressure -11.8% (val=115.760, normal=112.640, z=+4.39, trend decreasing); Component_A_Stream6 -5.9% (val=53.170, normal=72.770, z=+3.55, trend decreasing); Reactor_F...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
action
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0002 Overall anomaly score: 1.214 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: dynamic mode (dynamics dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.5566 (threshold = 0.68...
Direct action: Inspect the A/C feed ratio controller setpoint and the feed control valves. Target subsystem: feed_system. Safety precaution: correlation does not prove causation; verify on site. Severity: medium.
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
severity
severity
1
A/C feed ratio step change
medium
An anomaly was detected in the TEP. The strongest deviations are: A_C_Feed_Flow -38.3% (trend decreasing); Reactor_Pressure -11.8% (trend decreasing); Component_A_Stream6 -5.9% (trend decreasing). The anomaly score is 1.21. Use the severity rubric. What severity should this anomaly be assigned, and why? Respond with ON...
{"severity": "medium", "reasoning": "The largest deviation magnitude is 6% and the temporal sequence and affected subsystem (feed_system) indicate a medium event."}
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
discrimination
discrimination
1
A/C feed ratio step change
medium
An anomaly was detected in the TEP. Top deviations: A_C_Feed_Flow -38.3% (trend: decreasing); Reactor_Pressure -11.8% (trend: decreasing); Component_A_Stream6 -5.9% (trend: decreasing); Reactor_Feed_Rate -17.9% (trend: decreasing). Temporal order: A_C_Feed_Flow, then Reactor_Pressure, then Component_A_Stream6. Two cand...
{"root_cause": "A/C feed ratio step change", "reasoning": "A/C feed ratio step change: the initiating variable A_C_Feed_Flow decreased first, consistent with The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pres...
{ "event_id": "ANOM-T0002", "anomaly_score": 1.214, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 7.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.4493688608715288...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
report
report
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
{"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 3.49. The dominant deviations are in A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -31.5% (trend decr...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Why do you think the feed system is the most likely cause?
The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system disturbance. The key point is the temporal ordering: the initiating variable changed first and the downst...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
How serious is this anomaly?
The severity is assessed as medium. This is based on the magnitude of the sensor deviations and the confidence of the evidence; monitor the affected variables and follow the recommended action.
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Which sensors should I inspect?
Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure.
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
followup
followup_generic
1
A/C feed ratio step change
medium
Could the cause be something else?
Yes. The evidence supports the candidate cause but does not prove it. The uncertainty is that correlation and temporal order are supporting evidence, not proof. On-site inspection is needed to confirm the root cause.
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
metrics
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
Overall anomaly score 3.489 for ANOM-T0003. LSTM autoencoder reconstruction error = 0.8805 (threshold = 0.6874, ratio = 1.28x, ALARMED). CVA dynamics Q-statistic = 143.9 (threshold = 239.8, ratio = 0.60x, Normal (below limit)). Dominant lag 2, slow drift ratio 0.52.
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
evidence_why
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
Threshold exceedance: LSTM 0.8805 vs 0.6874 (ALARMED); CVA Q 143.9 vs 239.8 (Normal (below limit)). Telemetry excursions: A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, n...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
sensor_values
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
For ANOM-T0003: A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, normal=57.550, z=+2.13, trend decreasing); Reactor_Feed_Rate -11.8% (val=113.530, normal=67.450, z=+3.64, t...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
sensors_inspect
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
Inspect the sensors that deviated first and most strongly: A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure. Details: A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, n...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
overview_cause
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
ANOM-T0003 is a medium anomaly in subsystem feed_system. Likely root cause: A/C feed ratio step change. The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pressure. This ordering is consistent with a feed-system d...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
severity
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
Severity is medium. This is based on the sensor deviation magnitudes (A_C_Feed_Flow -31.5% (val=94.630, normal=112.100, z=+3.89, trend decreasing); Component_A_Stream6 -6.2% (val=103.250, normal=89.290, z=+5.08, trend decreasing); Reactor_Pressure -8.2% (val=51.780, normal=57.550, z=+2.13, trend decreasing); Reactor_Fe...
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
grounded_qa
action
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0003 Overall anomaly score: 3.489 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: lstm_ae mode (level dynamic pattern) - LSTM Autoencoder: reconstruction error = 0.8805 (threshold = 0.6874,...
Direct action: Inspect the A/C feed ratio controller setpoint and the feed control valves. Target subsystem: feed_system. Safety precaution: correlation does not prove causation; verify on site. Severity: medium.
You are an industrial process assistant and control room diagnostic expert for the Tennessee Eastman Process (TEP). An operator is asking about a specific detected anomaly event. The user message contains the full incident telemetry (detector scores vs thresholds, sensor observed vs normal values with deviation %, temp...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
severity
severity
1
A/C feed ratio step change
medium
An anomaly was detected in the TEP. The strongest deviations are: A_C_Feed_Flow -31.5% (trend decreasing); Component_A_Stream6 -6.2% (trend decreasing); Reactor_Pressure -8.2% (trend decreasing). The anomaly score is 3.49. Use the severity rubric. What severity should this anomaly be assigned, and why? Respond with ONL...
{"severity": "medium", "reasoning": "The largest deviation magnitude is 6% and the temporal sequence and affected subsystem (feed_system) indicate a medium event."}
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
discrimination
discrimination
1
A/C feed ratio step change
medium
An anomaly was detected in the TEP. Top deviations: A_C_Feed_Flow -31.5% (trend: decreasing); Component_A_Stream6 -6.2% (trend: decreasing); Reactor_Pressure -8.2% (trend: decreasing); Reactor_Feed_Rate -11.8% (trend: decreasing). Temporal order: A_C_Feed_Flow, then Component_A_Stream6, then Reactor_Pressure. Two candi...
{"root_cause": "A/C feed ratio step change", "reasoning": "A/C feed ratio step change: the initiating variable A_C_Feed_Flow decreased first, consistent with The A/C feed ratio step changes the composition delivered to the reactor. The A/C feed flow changed first, followed by the reactor feed rate and then reactor pres...
{ "event_id": "ANOM-T0003", "anomaly_score": 3.489, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.1, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.7836849426704513...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
report
report
1
A/C feed ratio step change
medium
A new anomaly has been detected in the Tennessee Eastman Process. Event ID: ANOM-T0004 Overall anomaly score: 2.849 Assessed severity level: medium (evaluated against TEP process safety limits) Detector trigger: both mode (mixed dynamic pattern) - LSTM Autoencoder: reconstruction error = 1.6801 (threshold = 0.6874, ra...
{"summary": "An anomaly was detected in the Tennessee Eastman Process with anomaly score 2.85. The dominant deviations are in A_C_Feed_Flow, Component_A_Stream6, Reactor_Pressure.", "root_cause": "A/C feed ratio step change", "affected_subsystem": "feed_system", "evidence": ["A_C_Feed_Flow changed by -27.2% (trend decr...
{ "event_id": "ANOM-T0004", "anomaly_score": 2.849, "severity": "medium", "pre_anomaly_context": { "duration_minutes": 6.4, "status": "normal" }, "top_anomalous_sensors": [ { "index": 0, "name": "A_C_Feed_Flow", "display_name": "A_C_Feed_Flow", "error": 0.3823481300335534...
{ "name": "A/C feed ratio step change", "subsystem": "feed_system", "severity": "medium" }
End of preview. Expand in Data Studio

Polyvalent TEP Report Distillation Dataset

Distilled root-cause analysis reports and operator diagnostic dialogues for industrial anomaly response on the Tennessee Eastman Process (TEP).

Dataset Summary

  • Teacher Model: qwen2.5:32b (Apache-2.0)
  • Source Telemetry: Rieth et al. (2017) Tennessee Eastman Process simulation dataset, Harvard Dataverse (CC0 1.0).
  • Target Full Splits: 3,168 rows (2,376 train, 396 validation, 396 test across all 22 process fault IDs).
  • In-Repo Included Split Slice: 2,016 train, 96 validation, 96 test rows in both Apache Arrow and JSONL formats.

Generation Procedure

  1. Simulated multi-hour sensor trajectories for 22 TEP fault scenarios (reactor feed composition, cooling water temperature loss, valve sticking, condenser fouling).
  2. Distilled expert engineering diagnostics from qwen2.5:32b using prompt grounding contracts.
  3. Automated filter rules enforced 100% grounding to authentic sensor IDs (XMEAS 1-41, XMV 1-12) and discarded ungrounded causal claims.

Licence and Source Attributions

  • Dataset: CC BY 4.0
  • Underlying physical process simulation data: CC0 1.0 (Rieth et al. 2017)
  • Teacher LLM: Apache-2.0 (qwen2.5:32b)

Citation

@data{rieth2017tep,
  author = {Rieth, C. A. and Amsel, B. D. and Tran, R. and Maia, M. B.},
  publisher = {Harvard Dataverse},
  title = {{Tennessee Eastman Process Simulation Data for Anomaly Detection}},
  year = {2017},
  doi = {10.7910/DVN/6C3JR1}
}

@article{polyvalent2026,
  title={Polyvalent: Single-Base Multi-Specialist Architecture with Dynamic Adapter Residency},
  author={Polyvalent Research Team},
  year={2026}
}
Downloads last month
-

Models trained or fine-tuned on Pushkarrrr15151/PolyVL-tep-report-distill