SSX360 Evidence Tools
Collection
Free evidence tools for CRA, AI-agent/MCP, C-UAS, post-quantum, OT and bank-exam obligations. MCP-ready; every result carries a verifiable receipt. • 9 items • Updated
event_type stringclasses 2
values | report stringclasses 3
values | deadline stringclasses 4
values | clock_start stringclasses 3
values | hours int64 24 336 ⌀ | article stringclasses 6
values | required_content listlengths 2 5 |
|---|---|---|---|---|---|---|
actively_exploited_vulnerability | early_warning | 24h after awareness | awareness | 24 | Art. 14(2)(a) | [
"Product(s) with digital elements affected (name, version)",
"Member States where the manufacturer knows the product is made available"
] |
actively_exploited_vulnerability | notification | 72h after awareness | awareness | 72 | Art. 14(2)(b) | [
"General information on the product concerned",
"General nature of the exploit and the vulnerability",
"Corrective or mitigating measures taken",
"Measures users can take",
"How sensitive the manufacturer considers the notified information to be"
] |
actively_exploited_vulnerability | final_report | 14 days after a corrective or mitigating measure is available | corrective_measure_available | 336 | Art. 14(2)(c) | [
"Description of the vulnerability, including severity and impact",
"Information on any malicious actor that exploited it, where available",
"Details of the security update or other corrective measures made available"
] |
severe_incident | early_warning | 24h after awareness | awareness | 24 | Art. 14(4)(a) | [
"Whether the incident is suspected of being caused by unlawful or malicious acts",
"Member States where the manufacturer knows the product is made available"
] |
severe_incident | notification | 72h after awareness | awareness | 72 | Art. 14(4)(b) | [
"Nature of the incident",
"Initial assessment of the incident",
"Corrective or mitigating measures taken",
"Measures users can take",
"How sensitive the manufacturer considers the notified information to be"
] |
severe_incident | final_report | one month after the incident notification | notification_submitted | null | Art. 14(4)(c) | [
"Detailed description, including severity and impact",
"Type of threat or root cause likely to have triggered the incident",
"Applied and ongoing mitigation measures"
] |
Machine-readable reporting clocks and required content for EU Cyber Resilience Act (Regulation (EU) 2024/2847) Article 14. Obligations apply from 11 September 2026. Each row covers one report: event type, deadline, what starts the clock, and the content the report must carry.
This is SSX360's structured summary of the regulation. It is not the legal text. Check the Official Journal and your counsel before filing.
Notes: the ENISA Single Reporting Platform does not timestamp your internal awareness, and drafts on the platform don't count as submission. Keep your own tamper-evident awareness record.