BUSI — Breast Ultrasound Images Dataset
Re-hosted mirror of the Breast Ultrasound Images Dataset (Al-Dhabyani et al., 2020), collected at Baheya Hospital, Cairo, Egypt and originally distributed via the Cairo University Scholar page of co-author Aly Fahmy.
This mirror is intended for use with EasyMedSeg and provides:
- A single canonical source (the original Cairo Univ. URL has unstable TLS).
- Parquet schema with one row per image and a single binary mask.
- For images with multifocal lesions, the multiple
_mask_N.pngfiles in the original release are merged into one binary mask via per-pixel logical OR (the convention adopted by the paper and by BUS-Set / Thomas et al. 2023).
Composition
| Class | Images | Multifocal cases |
|---|---|---|
| benign | 437 | 16 |
| malignant | 210 | 1 |
| normal | 133 | 0 |
| Total | 780 | 17 |
Image dimensions are variable (~190–719 px, average ~500×500 px). Source release is from 2018; 600 female patients, ages 25–75; GE LOGIQ E9 / E9 Agile B-mode.
Splits
BUSI has no official train/val/test split. This release ships a single
train split. Downstream code is expected to define its own splits
(BUS-Set provides reproducible ones).
Schema
| Column | Type | Description |
|---|---|---|
image |
Image |
Source PNG (RGB) |
mask |
Image |
Binary mask (L mode, 0/255) — OR-merged across all mask files |
class_label |
string |
"benign" / "malignant" / "normal" |
image_id |
string |
e.g., "benign (100)" |
has_multifocal_lesion |
bool |
True if the source had >1 mask file |
Known data-quality caveats
Per Pawłowska et al. (2023, Data in Brief, PMC10293973):
235 duplicated images (19%); 8 lesions appear in both benign and malignant folders (label leakage).- ~70 axilla (non-breast) images mis-categorized as breast.
- 295 images with overlaid annotations (calipers, doppler markers, text) intersecting the lesion ROI.
- ≥7 images contain a visible biopsy needle.
This mirror does not modify the source files (other than mask merging) — the above issues are inherited as-is. Cite Pawłowska et al. when reporting cleanups.
Citation
@article{Aldhabyani2020BUSI,
title = {Dataset of breast ultrasound images},
author = {Al-Dhabyani, Walid and Gomaa, Mohammed and Khaled, Hussein and Fahmy, Aly},
journal = {Data in Brief},
volume = {28},
pages = {104863},
year = {2020},
doi = {10.1016/j.dib.2019.104863}
}
License
CC BY 4.0
Redistribution and commercial use are permitted under the terms below.
Source of the terms: https://pmc.ncbi.nlm.nih.gov/articles/PMC6906728/
Audit note (verbatim from the MedOtter dataset card):
Primary source (Data in Brief 2020, Al-Dhabyani et al.) states "open access article under the CC BY license (creativecommons.org/licenses/by/4.0/)". CC BY permits free redistribution + commercial use with attribution. HF tag "other" should be cc-by-4.0; only gap is the tag/attribution notice.
Please cite:
Al-Dhabyani W, Gomaa M, Khaled H, Fahmy A. Dataset of breast ultrasound images. *Data in Brief*. 2019;28:104863. doi:10.1016/j.dib.2019.104863