|
Download cases/case01/task.md from Tauben/PhysClosureBench: direct link, hf CLI and curl.
- Browser
- Download file 5.86 kB
-
https://huggingface.co/datasets/Tauben/PhysClosureBench/resolve/main/cases/case01/task.md
- Command line
-
hf download hf://datasets/Tauben/PhysClosureBench/cases/case01/task.md
-
curl -L -o task.md https://huggingface.co/datasets/Tauben/PhysClosureBench/resolve/main/cases/case01/task.md
5.86 kB
| # Phase characterization in a weak-pulse/strong-field ionization model | |
| ## Background | |
| Directly characterizing the carrier-envelope phase (CEP) of a weak circularly | |
| polarized isolated attosecond pulse (IAP) is difficult because the pulse does | |
| not by itself provide the strongly nonlinear response used in established | |
| infrared CEP measurements. Consider ground-state hydrogen exposed to the weak | |
| IAP together with a much stronger, phase-stable circularly polarized infrared | |
| (IR) field, with the emitted photoelectrons observed in the laser-polarization | |
| plane. | |
| ## Research problem | |
| Develop and assess a reproducible angular-streaking strategy for characterizing | |
| the absolute IAP CEP, within the stated laboratory phase convention, from the | |
| final photoelectron momentum or angular distribution in this two-pulse | |
| configuration. Treat the known IR phase as the phase reference. | |
| Demonstrate, by varying the IAP CEP, whether a usable phase-to-observable | |
| relation can be established and whether the same diagnostic remains applicable | |
| at both specified IAP wavelengths. Determine the level of CEP characterization | |
| supported by the stated model and your calculated evidence. | |
| How the strategy is constructed and substantiated is for you to decide. Assess | |
| its success from the calculated evidence rather than assuming it in advance. | |
| ## Physical inputs | |
| Use atomic units in the field and strong-field calculations. For each | |
| individual pulse $i\in\{\mathrm{IAP},\mathrm{IR}\}$, use the source-stated | |
| finite-support field | |
| $$ | |
| \mathbf E_i(t)=E_{0,i} | |
| \left[ | |
| \cos(\omega_i t+\theta_i)\,\hat{\mathbf x} | |
| -\sin(\omega_i t+\theta_i)\,\hat{\mathbf y} | |
| \right] | |
| \cos^2\!\left(\frac{\pi t}{\tau_i}\right), | |
| \qquad |t|<\frac{\tau_i}{2}, | |
| $$ | |
| and $\mathbf E_i(t)=0$ outside this support. The two pulse envelopes share the | |
| same time origin. The fields rotate clockwise in the $x$-$y$ plane under this | |
| convention. | |
| | Quantity | Value or condition | | |
| |---|---| | |
| | Target | Ground-state hydrogen ($1s$) | | |
| | Ionization potential | $I_p=0.5$ a.u. | | |
| | IAP wavelengths | 67 nm and 100 nm | | |
| | IR wavelength | 800 nm | | |
| | Peak intensities | $I_{\mathrm{IAP}}=2\times10^{11}\,\mathrm{W/cm^2}$ and $I_{\mathrm{IR}}=2\times10^{14}\,\mathrm{W/cm^2}$ | | |
| | Field amplitudes | $E_{0,i}=\sqrt{I_i/(3.51\times10^{16})}$ a.u. | | |
| | Pulse durations | Four optical cycles, $\tau_i=4(2\pi/\omega_i)$ | | |
| | Carrier frequencies | $\omega_i=2\pi c/\lambda_i$, converted consistently to atomic units | | |
| | Phase reference | $\theta_{\mathrm{IR}}=0$; $\theta_{\mathrm{IAP}}$ is the characterization variable | | |
| | Momentum domain of interest | Laser-polarization plane, $p_z=0$ | | |
| State any conversion constants and phase, vector-potential, momentum-axis, and | |
| angular conventions used in your work. | |
| ## Model scope | |
| Use a standard ground-state-hydrogen ($1s$) ADK treatment as the simplified | |
| tunnelling baseline and a standard strong-field approximation (SFA) for the | |
| coherent final photoelectron calculation. Select and cite the precise standard | |
| formulations you use. In the ADK-level model, neglect ground-state depletion | |
| and post-release Coulomb action. Do not add a full TDSE calculation to the | |
| required task. | |
| All numerical and diagnostic choices not fixed above are yours. The same | |
| physical and phase conventions must be used consistently, and the same | |
| diagnostic strategy must be tested at both IAP wavelengths. Any normalization | |
| or display scaling must be declared and kept common wherever relative | |
| magnitudes are used as scientific evidence. Absolute photoelectron yield is | |
| not a grading target unless it is fixed by the formulation you adopt. | |
| You are responsible for checking that your numerical results are sufficiently | |
| reliable and reproducible to support the conclusions you report. No particular | |
| grid, solver, convergence sequence, error metric, or validation procedure is | |
| prescribed. | |
| ## Submission | |
| Submit a self-contained scientific report and an offline reproduction package | |
| containing the code, the numerical data underlying the reported evidence, the | |
| a provenance note listing every offline source or software document actually consulted and the method basis for items supplied from general knowledge, and concise run and environment information. The | |
| scientific organization of the report and supporting evidence, as well as | |
| filenames below the common top-level collection entry points, are yours. No | |
| full exploratory history or examiner-selected numerical method is required. | |
| The active examination resources and limits are defined in the companion | |
| `resource_limits.json`. All retained production calculations must run | |
| within that fixed allocation and active wall time. More expensive modelling | |
| does not receive additional credit. | |
| ## Reference and integrity policy | |
| This examination is conducted without network access or live literature | |
| retrieval. You may rely on your existing general scientific knowledge and, if any are | |
| explicitly supplied with the examination, on those offline materials or | |
| software documentation. Record every such source actually consulted. For formulas, | |
| methods, constants, or conventions used from general knowledge rather than a | |
| consulted source, state enough of the method basis, definition, value, units, | |
| and convention to make the calculation auditable; do not invent a citation. | |
| You are not required to identify or prove a publication date or to retrieve | |
| literature during the examination. | |
| The hidden target article and its identifying metadata, figures or captions, | |
| supplementary material, author code or data, target-specific reproduction | |
| code, solution or scoring material, online solutions, and worked | |
| reproductions of this case must not be used. All submitted scientific figures | |
| and numerical data must be generated by your own implementation of the stated | |
| problem. | |
| See [submission requirements](../../submission_requirements.md) for the common submission entry points. | |