Tauben's picture
Upload 255 files
2c93ae3 verified
|
Raw History Blame Contribute Delete
6.11 kB
# Causal time-domain inference in a driven three-state system
## Background
Attosecond transient-absorption spectra can encode the causal electronic
response of a laser-dressed system. Recovering the corresponding motion in the
time domain would make the spectrum a direct probe of ultrafast dynamics, but
an experimental attosecond probe has a finite duration rather than the ideal
impulsive form often assumed in such an interpretation.
## Research problem
Develop and assess a reproducible procedure, within causal linear-response
theory, for recovering the time-dependent dipole motion of the infrared-dressed
system below from its transient-absorption signal. Determine how faithfully the
relevant motion can be recovered for attosecond-probe durations of 100, 300 and
500 as, why the finite probe matters, and what physical claim is supported by
the calculated evidence.
The derivation, numerical realization, signal processing, diagnostic design,
choice of figures and structure of the scientific argument are yours. Assess
the reconstruction from computed evidence rather than assuming that it works.
## Physical inputs
Use atomic units for the dynamical calculation. The model contains a ground
state $|g\rangle$, a dipole-allowed excited state $|a\rangle$ and an
infrared-coupled state $|f\rangle$. The only nonzero transition dipoles in the
model are
$$
\mu_{ga}=0.34,\qquad \mu_{af}=2.72,
$$
with energy differences
$$
E_a-E_g=21.057\ \mathrm{eV},\qquad E_f-E_a=-0.82\ \mathrm{eV}.
$$
The system is initially in $|g\rangle$ before either field is appreciable.
Use electric-dipole coupling and the following linearly polarized fields. The
attosecond probe is
$$
E_X(t)=E_{X0}e^{-\lambda |t|}\cos(\omega_X t),
\qquad \tau_X=\frac{2\ln 2}{\lambda},
$$
with photon energy $21\ \mathrm{eV}$, peak intensity
$10^{10}\ \mathrm{W\,cm^{-2}}$, and $\tau_X=100$, 300 or 500 as. Define the
probe centre as $t=0$.
The infrared field is
$$
E_{\mathrm{IR}}(t,\tau)=E_0 A(t-\tau)
\cos[\omega_{\mathrm{IR}}(t-\tau)],
$$
where
$$
A(u)=
\begin{cases}
\cos^2\!\left(\dfrac{\omega_{\mathrm{IR}}u}{2N}\right),
& |u|\le N\pi/\omega_{\mathrm{IR}},\\[4pt]
0,&\text{otherwise},
\end{cases}
$$
$N=10$, $\hbar\omega_{\mathrm{IR}}=0.82\ \mathrm{eV}$ and the peak intensity
is $5\ \mathrm{TW\,cm^{-2}}$. Set the infrared-pulse centre five infrared
optical cycles after the probe centre. Obtain field amplitudes from a standard,
consistently reported intensity conversion.
For this task, the source-model decoherence is imposed by the following
author-supplied policy. First solve the driven three-state problem and obtain
its physical real dipole $d_0(t)$. Then define
$$
d_{\mathrm{phys}}(t)=
\begin{cases}
d_0(t),&t\le 0,\\
d_0(t)e^{-t/(50\ \mathrm{fs})},&t>0.
\end{cases}
$$
Apply this operation before constructing the absorption signal. Do not put it
in the Hamiltonian, reinterpret it as population or amplitude damping, or
apply an additional Fourier apodization window.
State the time, frequency, Fourier-sign, dipole-sign and display conventions
used in your work. Absolute arbitrary-unit vertical scale is not a grading
target.
## Method and scope
Use the standard three-level time-dependent Schrödinger equation for the
stated couplings and a causal linear-response or Kramers-Kronig reconstruction
from the positive-frequency transient-absorption signal. You may choose and
cite standard formulations consistent with these method families. Do not add
levels, ionization channels or nonlinear probe response to the graded model.
All numerical choices not fixed above are yours. Check that the reported
signals are sufficiently reliable and reproducible to support your claim; no
particular grid, record length, propagator, transform algorithm, regularizer,
comparison metric or refinement sequence is prescribed.
## Submission
Submit one self-contained scientific report and an offline reproduction
package. The report must answer the research question from your calculated
time-dependent reconstruction and must contain enough quantitative evidence
to audit every probe-duration-dependent claim. The selection and organization
of that evidence are yours.
Include a provenance note listing every offline source or software document actually consulted and the method basis for items supplied from general knowledge.
Include the derivation actually used, source code, an executable command or
script, machine-readable data underlying the reported evidence, plotting or
analysis code, references, and concise run and environment information. No
fixed file tree, filename scheme, complete exploratory history or
examiner-selected intermediate plot is required.
The active examination resources and limits are defined in the companion
`resource_limits.json`. All retained production calculations must run
within that fixed allocation and active wall time. More expensive modelling
does not receive additional credit.
## Reference and integrity policy
This examination is conducted without network access or live literature
retrieval. You may rely on your existing general scientific knowledge and, if any are
explicitly supplied with the examination, on those offline materials or
software documentation. Record every such source actually consulted. For formulas,
methods, constants, or conventions used from general knowledge rather than a
consulted source, state enough of the method basis, definition, value, units,
and convention to make the calculation auditable; do not invent a citation.
You are not required to identify or prove a publication date or to retrieve
literature during the examination.
The hidden target article and its identifying metadata, figures or captions,
supplementary material, author code or data, target-specific reproduction
code, solution or scoring material, online solutions, and worked
reproductions of this case must not be used. All submitted scientific figures
and numerical data must be generated by your own implementation of the stated
problem.
See [submission requirements](../../submission_requirements.md) for the common submission entry points.