content stringlengths 500 1.99k | filename stringclasses 5
values | Q stringlengths 0 342 |
|---|---|---|
For the lower extremities, the speed boundaries are easier to interpret in terms of what is happening during a given test, but for many instances the acceleration responses are likely more informative. For example, lower extremity injury is probably related to higher acceleration of the floor, and therefore higher acce... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do variations in acceleration rates, such as jerk, and directional velocities contribute to the risk and assessment of lower extremity injuries during biomechanical testing? |
For the pelvis, injury might be associated with higher magnitude but shorter duration acceleration. However, pelvis damage still occurred for a few cases exhibiting relatively lower accelerations, but the durations were relatively longer. This is in keeping with the general notion that larger inputs can be tolerated by... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can variations in acceleration duration and speed influence the likelihood and severity of pelvic injuries in biomechanical assessments? |
PPE is associated with increased injury incidence, lower pelvis speed responses, and lower lumbar spine speed. However, the primary effect of the PPE was support for the trunk of the PMHS throughout a test. The PPE reduced the slumping of the torso and rotation of the shoulders of the PMHS. The PPE resulted in greater ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the use of PPE influence the biomechanical response and injury outcome in post-mortem human surrogate (PMHS) testing, particularly concerning the dynamics of torso slumping, shoulder rotation, and soft tissue compression in the pelvic and thigh regions? |
MS11 and MS14 were conducted using approximately 1!_2 the threat size employed for the Enhanced tests. This was done to obtain biofidelity data in the absence of pelvis and spine damage. Reduction of the threat served to decrease both vertical and horizontal inputs to the PMHS. The horizontal input stemmed from flexure... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can biomechanical testing methodologies be refined to differentiate and measure the distinct effects of horizontal versus vertical loading on the lumbar spine, pelvis, and lower extremities in order to better assess potential injuries in impact scenarios? |
Scatter plots were used to show comparisons between occupant types, and to elucidate possible trends in the peak and time-to-peak responses. To determine if the events were similar, rig sensors used for the ATD and PMHS tests were compared. In general, the acceleration magnitudes and times-to-peak for both the floor an... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the similarities in peak acceleration magnitudes and time-to-peak responses between ATD and PMHS tests impact the reliability of biomechanical injury assessments for different occupant types? |
The ATD and PMHS response were compared in terms of peaks and times-to-peak also. In the pelvis, the ATD had lower peak acceleration with shorter time-to-peak compared to the PMHS. In contrast, the velocity results indicated higher peak velocities and longer time-to-peak in the ATD. The interaction between the seat and... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | What biomechanical factors could explain the differences in peak acceleration and velocity between the ATD and PMHS responses in the pelvis during under-body blast simulations, and how might these differences affect the accuracy of injury assessment? |
For the tibia, the ATD had similar peak values and times-to-peak compared to the PMHS. This similarity is likely due to the interaction of the foot with rapidly accelerating floor. Differences in material properties and geometry between the subjects (contactinterface phenomena) are secondary to the inertial effects tha... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the differences in material properties and geometry between the ATD and PMHS models affect the overall assessment of injury biomechanics in a rapidly accelerating environment? |
These tests were conducted using a rigid seatback and bottom. The PMHS torso was essentially flat against the seatback. The ATD was incapable of achieving this posture due to its rigid and angulated thoracic spine. Further, since the ATD was designed to mimic the posture of a seated automotive driver, erect seating pos... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the difference in posture between the PMHS and the ATD influence the biomechanical assessment of injury risk in testing scenarios using rigid seatbacks? |
All PMHS damage produced in this test series are present in the list of theater reported injuries. Although the ALF system produced damage to the lumbar spine, pelvis, ankle, and foot that reflect battlefield injuries, there is no capability to assess the potential for these results using an ATD in LFTE. There are subs... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the biomechanical differences between PMHS and Hybrid III ATDs impact the assessment of lumbar spine, pelvis, ankle, and foot injuries in high-rate, vertical loading environments, and what improvements can be made to current ATD models to better simulate battlefield injury mechanisms? |
Initial Seat Response (2.2 m s) . The seat is rigidly attached to side frame (cage) of the blast buck. The first seat motion is horizontal to platform due to bowing of the side frame, and some bowing of the floor frame. This is largely related to the inertia of the cage and overhead mass, as well as the inertia of the ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the relative motion between the seatback and the backs of the surrogates influence the potential for spinal or soft tissue injuries in the context of the described blast scenario? |
By this time, all boot and foot compliance has been exhausted. The total compliance was estimated to be 1.25 (right) and 2;mathrmcm (left) for this test. This is shown in Figure 35. It is difficult to differentiate between the boot and foot deformations. It is likely that the tibia has experienced little load (inertial... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do variations in compliance between different boots, due to manufacturing tolerances, impact the biomechanical assessment of lower limb injuries in LFTE testing? |
Ankle Fracture (boldsymbol9,mboldsymbols) . The right calcaneus of PMHS 6517 fractured 7.6mathrmms after the onset of foot motion as indicated by strain gage response 9mathrmms after Tzero). All compliance in the boot and foot is exhausted just prior to this time. This indicates that foot injuries happen very early in ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the timing and nature of loading affect the likelihood and severity of calcaneus fractures during rapid foot acceleration events, and what biomechanical factors might contribute to unilateral injury predominance in PMHS subjects? |
Ankle and Foot Kinematics after Floor Contact is Lost. Just prior to the PMHS and ATD heels losing contact with the floor, the initial response about the ankles is dorsiflexion. As the heels begin to separate from the floor, the PMHS ankles assume moderate dorsiflexion, while the ATD demonstrates extreme dorsiflexion. ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the differences in ankle dorsiflexion and plantarflexion behavior between PMHS and ATD during loss of floor contact impact the accuracy of injury prediction models for real-world scenarios? |
Onset of Pelvis Fracture (l2.7m s) . The pelvis first begins to fracture 11.6,mathrmms after the onset of foot motion as indicated by response from the strain gage adhered to the right acetabulum (12.7 ms after Tzero). Figure 37 shows the interaction of the back and buttock of the PMHS at this time. Substantial compres... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the time delay between foot motion onset and the initiation of pelvic fractures, particularly in the ischial tuberosities, influence the assessment of pelvic injury severity in biomechanical studies? |
All observed pelvis damage occurred within 15mathrmms of the onset of foot motion in these tests. The foreaft seat motion and non-padded seat likely contributed to much of the pelvis damage other than to the coccyx, tuberosities, and rami. Acetabulum damage likely resulted from a combination of both vertical and horizo... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might variations in pelvis angle influence the risk of injury in different seating conditions, and what methods could be used to accurately assess the contribution of both vertical and horizontal load components to acetabulum damage in biomechanical testing environments? |
Trunk Response (36 ms). During MS2, the PMHS torso height reduced approximately 8.4mathrmcm by 36mathrmms ,as shown in Figure 38. The original torso height was estimated to be 49.8;;mathrmcm at the start of the event. While this is a known phenomenon associated with pilot ejection from aircraft, it was not considered p... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the rigidity of the ATD's thoracic spine impact the accuracy of injury assessments during pilot ejection scenarios, and what modifications could be made to improve biofidelity in high loading rate tests? |
The ATD achieves full neck flexion near 70mathrmms after Tzero. At this time the PMHS neck undergoes axial elongation. The initial position and neck stiffness of the ATD facilitates early flexion. The peak ATD neck flexion is approximately 44circ from horizontal, and the peak rate of flexion is approximately 2200circma... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do differences in neck stiffness between the ATD and PMHS models affect the timing and extent of neck flexion, and what implications might these differences have for assessing potential neck injuries in crash scenarios? |
Previous research has been conducted on occupant response to vertical loading in space capsule returnto-earth loading scenarios, helicopter crash, and ejection seats. While these types of events are more similar to UBB than a frontal motor vehicle crash, they do not involve loading rates that allow for a direct compari... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the impact duration and peak acceleration in vertical loading scenarios, such as space capsule landings and ejection seat tests, influence the biomechanical assessment of injury risk, and what considerations are necessary when comparing these events to under-body blast loading conditions? |
The primary limitation of this study is that few repeat conditions were tested. This resulted in part due to the need to vary several parameters within a relatively small cohort of specimens. The intent was to attempt to loosely bound the PMHS kinematics responses for a variety of scenarios, to investigate damage patte... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do variations in the Anthropomorphic Load Fixture (ALF) configuration influence the observed patterns of injury and damage in Post-Mortem Human Subject (PMHS) testing, and what implications does this have for the consistency and reliability of biomechanical kinematics assessments? |
Another substantive limitation is related to negative aspects of the ALF performance. Deformation of the buck cage during some events caused the seatbacks to impact the surrogates from behind for enhanced charge levels. This deformation was related to flexure of the bottom frame of the buck and the large overhead mass ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the deformation of the buck cage and its impact on the posterior of the PMHS specifically contribute to the characterization and severity of pelvic injuries in biomechanical assessments? |
Although direct comparisons were limited to pairs of curves, CORA was used to assess response similarity. CORA creates an artificial corridor based upon an average signal. In this study, signals could not be averaged. However, CORA still provided the ability to determine signal correspondence based upon shape, magnitud... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the tightening of outer corridor boundaries from -50 to -25 influence the reliability of injury assessment using PMHS signals in biomechanics studies, and what implications does this have for evaluating the biomechanical response to impact? |
For the planar motion analyses, there were two limitations. First, for some of the ATD tests, markers were not always placed where needed. Therefore, physical landmarks on the dummies, or approximations thereof, were tracked to generate the motion response envelops. However, the errors introduced by this process are as... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can inaccuracies in marker placement and planar limitation influence the biomechanical analysis and injury assessment outcomes in Anthropomorphic Test Device (ATD) tests? |
The Hybrid III was designed for use in the automotive environment. Use of the ATD for UBB test conditions is outside of the loading environment used for its development and its intended purpose. Currently, there is no better countermeasure assessment tool available to the military. The use of the Hybrid III outside of ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | What are the biomechanical limitations and potential inaccuracies when using the Hybrid III ATD for under body blast (UBB) test conditions, and how might these impact the assessment of military-related injuries? |
Specialized PMHS preparation techniques were developed as part of this study. Fourteen tests (Matrix Shots) were conducted using fourteen PMHS and the Hybrid III ATD. For each shot, the ALF carried either two PMHS or two ATDs or one of each. Two crew postures were examined, having either a 90 or 120-degree angle at the... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the different knee angles (90 degrees vs. 120 degrees) affect the kinematic and injury responses of PMHS and ATDs in blast scenarios, and what implications might these differences have for developing more effective personal protective equipment? |
For this test series, custom designed bone cells were developed to measure the load in the lower extremities without compromising the bone response. The current concept used multiple strain gages or strain gage rosettes in Wheatstone bridge configurations. One benefit to this configuration is that only one data channel... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the placement of axial and shear bone cells on the femur and tibia contribute to the assessment of load-bearing capacity and potential injury mechanisms in these regions? |
Following specimen preparation, the bone cells underwent a pre-test calibration procedure in the event the bone was damaged during the test. The gage arrays and a Denton model 1516 uniaxial load cell were connected to the data acquisition system. There were three body positions used to load the tibia and femur load cel... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the different loading positions (straight leg through the heel, bent knee through the knee, and braced hip through the knee) influence the potential for injury to the tibia and femur, and what biomechanical factors should be considered in evaluating the risk of damage to these bones under each condition? |
Some sources of error in the bone cells could be related to the bone cell implementation with variations in strain gage placement. Also, most of the axial bone cells show higher sensitivity in shear (cross-axis measurement) than in axial (calibrated measurement) load. Future work could address this discrepancy through ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can the observed variations in shear sensitivity relative to axial load in femur bone cells impact the assessment of injury mechanisms during activities involving knee loading? |
The pre-test calibration values resulted in peak load values that are within reason and that would be expected for these tests for the tibia axial loads (mathrmTz) and femur X-direction shear left(operatornameFxright) loads. The tibia axial (mathrmFmathbfz) bone cell needs further evaluation. There is cross-axis sensit... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the cross-axis sensitivity of the tibia axial load cell (Fz) impact the accuracy of injury assessment in scenarios where bending contamination is present? |
Figure E1 shows the left lower extremity mathrmFx and mathrmTz responses for Crew 1 of MS7. The operatornameFx response is inverted for the sake of this comparison. This crew was placed in the nominal posture. In the nominal posture, the operatornameFx and Tz values should be closer in magnitude than for the obtuse con... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the delayed operatornameFx load response in both nominal and obtuse postures influence the risk of injury to the lower extremity, considering the comparative magnitudes of Fx and Tz forces? |
The axial femur (mathrmFz) bone cells are not needed in the absence of knee impact and are not recommended for future testing. Conversely, the femur shear (operatornameFx) bone cell output is largely independent of point of application of load, and comparatively this cell design is not very sensitive to off-axis loadin... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can the optimization of the Tz bone cell design be approached to improve its sensitivity and accuracy in assessing tibial injuries under blast loading conditions? |
The motion blocks consisted of two primary components: a Delrin textsuperscripttextregistered interface mount, and an aluminum transducer block. The Delrin textsuperscripttextregistered mounts were shaped to match the contour of the bony structure to which it was to be attached. Therefore, separate interface blocks wer... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can the integration of Delrin® interface mounts and aluminum transducer blocks in motion analysis systems enhance the precision of biomechanical injury assessments in different body regions such as the head, neck, and lower extremities? |
In addition to being contoured to fit specific anatomical structures, the interface mounts were serrated on the surface that mated with the bones. This resulted in multiple contact points between each mount and bone. Prior to installation of a mountblock combination, sandpaper was glued to the denuded bone surfaces. Th... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the use of serrated interface mounts and high-tension cable ties impact the risk of bone fractures during biomechanical assessments, particularly in the pelvic region? |
To apply the gages, the bones were denuded of all tissue in the mounting location. The cortex of the bone was then sanded lightly. The sanded area was defatted using acetone. The area was then cleaned and dried using isopropyl alcohol. The prepared area was coated with two layers of cyanoacrylate. Each gage had 30 AWG ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the preparation and installation of strain gages on bone surfaces, as described in the text, contribute to the accuracy and reliability of biomechanical data used in the assessment of bone injuries? |
In order to prepare the bones to accept strain gages or motion blocks, the head, ribs, vertebrae, pelvis and bones of the lower extremities had to be accessed. For the head, access was gained by removing the posterior walls of the orbits. For the neck lateral incisions were made at the level of C6. For the ribs, small ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the surgical access points and preparation techniques described influence the biomechanical behavior of the skeletal and soft tissue structures during strain gage testing, and what considerations could mitigate potential alterations to injury assessment results? |
After installation of the gages and motion blocks, the strain gage wires and the shielded instrumentation cables were strain relieved using a combination of acrylic coating, suture, and small cable ties. The motion blocks were covered with latex sheets secured around the blocks using elastic bands. All instrumentation ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the method of routing instrumentation cables through subcutaneous tunnels, as described in the text, potentially impact the accuracy and reliability of data collected in biomechanical assessments and injury studies involving PMHS (Post-Mortem Human Subjects)? |
ABSTRACT Anthropometric test devices (ATDs), such as the Hybrid III crash-test dummy, have been used to simulate lowerextremity responses to military personnel subjected to loading conditions from anti-vehicular (AV) landmine blasts. Numerical simulations e.g., finite element (FE) analysis of such high-speed vertical ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the calibrated rate-dependent material properties of the heel-pad foam, foot skin, and lower-leg flesh in the Hybrid III crash-test dummy affect the accuracy of injury risk predictions in numerical simulations of anti-vehicular landmine blasts? |
High accelerations due to energy from AV landmines are detrimental to military personnel. When an AV landmine is detonated under a vehicle, a blast wave of energy is transmitted to the vehicular floor in microseconds, causing an extremely high acceleration and deflection of the floor plate (Wang et al. 2001). This tran... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | What biomechanical models or experimental approaches could be utilized to better understand the mechanisms and thresholds of lower extremity injuries caused by high accelerations from AV landmines detonating under vehicles? |
Current studies in which ATDs are used in blastloading scenarios are mainly focused on computational simulations (Nilakantan and Tabiei 2009; Tabiei and Nilakantan 2009). Material models used in the simulations, especially those for soft materials of the lower extremities (i.e., foams and rubbers), do not include effec... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the limitations of current computational simulations in accounting for strain-rate dependencies in soft material models affect the accuracy of injury assessments for the lower extremities in high-velocity blast scenarios? |
The goal of this study was to perform reliable, highspeed loading analyses using finite element modeling. To attain this goal, a combined experimental and computational approach was used to calibrate the properties of three soft materials used in the Hybrid III lower extremities, namely heel-pad foam, foot skin, and lo... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the calibration and optimization of material properties for heel-pad foam, foot skin, and lower-leg flesh in finite element models contribute to more accurate assessments of forces and injury risk during high-speed vertical impulsive loading events? |
Figure 1 shows the three components, from a lower extremity of the Hybrid III dummy (50th Male, Humanetics Innovative Solutions, Plymouth, MI), tested in this study. Since our focus was on tibial responses, only a limited number of parts were involved in simulations of load bearing. No permanent plastic deformations to... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | What role does the exclusion of strain-rate effects in metallic parts play in the accuracy of simulating the axial responses of the tibia during biomechanical evaluations of lower extremity injuries in blast experiments? |
The materials considered were heel-pad foam, foot skin, and lower-leg flesh. Heel-pad foam has a regular shape and uniform thickness, and can be tested using standard compression-testing techniques. Foot skin and lower-leg flesh are made with rubber materials. It would be impossible to dissect a flat sample from an ent... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How could the non-uniform thickness of foot skin and lower-leg flesh impact the accuracy of biomechanical models used for assessing injuries, and what alternative methods could be employed to address this challenge in compression-testing scenarios? |
Quasi-static and dynamic uniaxial compression tests were conducted on the foam samples at six different strain rates (0.01, 0.1, 1, 10, 140 and 600mathrms-1mathrm, with a servo hydraulic Instron machine (Model 1321 frame with a Model 8500 controller, Canton, MA). The loading ram had a flat end with an area of 100,times... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the differences in foam material behavior under various strain rates, as observed in quasi-static and dynamic uniaxial compression tests, inform the assessment and prediction of injury mechanisms in high-impact events? |
Vertical-impact tests on the Hybrid III foot were conducted using the same Instron as shown in Figure 4, at the constant speeds of 1, 5, and 10,mathrmms . The speeds were kept constant by a feedback linear displacement control. The ankle was fully affixed to a 12-inch diameter steel rod, which was connected to a load c... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do variations in the speed of vertical impact tests on the Hybrid III foot influence the biomechanical response and potential injury patterns observed in the ankle-foot complex? |
Bending tests of the Hybrid III lower leg were conducted using a weight drop system in which the weight was guided by two wires (see Figure 6). Use of this test system conforms to specifications from the National Operating Committee on Standards for Athletic Equipment (NOCSAE) for football helmet testing. The leg was f... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the bending test setup for the Hybrid III lower leg, specifically the use of wire-guided drop weight and affixed steel rods, replicate the biomechanical conditions experienced during a typical football tackle or impact, and how might these conditions inform assessments of potential tibial injuries? |
The plots of the representative force-deflection curves are shown in Figure 7, where it can be observed that there is no evidence that the rate affects the results. At the contact location between the impactor and the thin rubber layer (flesh), rebound took place almost instantaneously, after a small indentation occurr... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How could the minimal energy absorption by the thin rubber layer, as indicated by the similar force-deflection curves across different impact velocities, influence the risk of injury in biological tissues during high-velocity impacts? |
High-speed vertical loading tests on a full-body ATD were conducted to evaluate the overall responses of a lower extremity and to validate calibrations of the material models (see MATERIALS CALIBRATION for a full description). For each test, the Hybrid III dummy was placed horizontally on a system, which was used to ge... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do variations in impact velocity during high-speed vertical loading tests influence the biomechanical response and potential injury risk to the lower extremity in a Hybrid III ATD model? |
Mechanical responses were measured using two types of sensors, a bending moment transducer integrated in the upper tibia to measure M_y , and an axial force transducer on the lower tibia to measure F_z . No inertial compensation accelerometer was installed, because the purpose of the study was to compare computational ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | What biomechanical implications might the failure of the bending moment transducer during the first high-speed test have on the assessment of tibial injuries, and how could this impact the accuracy of computational model predictions? |
Material laws representing behaviors of the aforementioned three materials were calibrated using the test data presented in EXPERIMENTS. Material parameters for heel-pad foam were determined directly, based on compressive tests, and those for foot skin and lower-leg flesh were characterized based on an optimization app... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the calibrated material models of heel-pad foam, foot skin, and lower-leg flesh influence the accuracy of injury prediction and assessment in simulations utilizing the FEM of an ATD Hybrid III 50th percentile male? |
All of the simulations were conducted using the commercial finite element analysis (FEA) package, LS-DYNA 971_R4.2 (LSTC Livermore, CA). For comparison purposes, the predictions based on the original material models used by LSTC are also included. The material laws in LS-DYNA used by LSTC (denoted as the LSTC model) an... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the inclusion or exclusion of strain-rate effects in material models, such as those used in LS-DYNA simulations, impact the accuracy of injury biomechanical assessments in dynamic loading scenarios? |
The material parameters required by mathrmMAT_-83 were directly obtained from the compressive tests, and their values are shown in Appendix A. To evaluate the results of the material calibrations, these material parameters were input into the FEM to simulate the compressive tests on the heel-pad foam. The numerical mod... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the discrepancy between the LSTC model's predicted stress levels and the experimental results at higher displacements impact the biomechanical assessment of heel-pad injury risk during high-force compressive events? |
In this section, the FEM of the footimpactor system, shown in Figure 11b (to simulate the setup shown in Figure 4), in conjunction with a set of optimization procedures, was used to determine the material parameters of foot skin. The approach was based on reverse engineering (RE), in which material parameters were syst... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the use of reverse engineering and finite element modeling in determining the material parameters of foot skin contribute to a more accurate assessment of biomechanical responses during an impact event? |
The mechanical behavior of foot skin was described using the MAT_77_O (MAT_OGDEN_RUBBER) material card in LS-DYNA (LS-DYNA Keyword Users Manual 2007). The reason for using this material law was because it could describe the strain rate effect, which is disregarded in MAT 7. The optimization was implemented using commer... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the use of the MAT_77_O (MAT_OGDEN_RUBBER) material card in LS-DYNA aid in optimizing injury assessment models concerning strain rate effects on foot skin biomechanics? |
A previous study revealed that the two-term Ogden model was sufficient to represent the mechanical properties of the skin of an ATD head (Wood et al. 2010). Thus, in the present study, the model was assumed to have two termsthat is, n was set to 2 in Eq. (1). In the visco-elastic term, G and beta were timedependent, un... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the selection of parameters in the two-term Ogden model affect the accuracy of simulating the mechanical response and potential injury mechanisms of an ATD head during varying impact speeds? |
Step 2: A sampling algorithm, known as the Sobol algorithm (modeFRONTIER User manual 2008), was used to select the sampling points for the design-ofcomputer-experiments (DOCE) analysis within the range defined in Step 1. This method generated a uniform distribution pattern in the probability space. Input parameters, ta... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the variability in material properties, as examined through the 100 low-speed and high-speed impact simulations, influence the accuracy and reliability of injury prediction models in biomechanics? |
Based on the distributions of the index values, a response surface was built to obtain the optimum design. The response-surface method was a more efficient method to explicitly reflect an approximate functional relationship between the calculated and measured responses without simulating all possible combinations of de... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can the integration of response surface methodologies and genetic algorithms enhance the accuracy of predicting injury outcomes in biomechanical simulations? |
The results of the parametric optimization for foot skin are listed in Appendix A. Comparisons of the experimental data and the predictions from the models based on LSTC- and optimized WSUmaterial parameters are shown in Figure 14. Again, the simulation results with the original material laws provided by LSTC were also... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the accuracy of WSU material parameter predictions in foot skin simulations impact the assessment of injury risk compared to the original LSTC material laws? |
The optimized material models for heel-pad foam, foot skin, and lower-leg flesh were integrated into an FEM of the full-body Hybrid III dummy to simulate overall responses under high-speed vertical impacts, as described in EXPERIMENTS. The predictions of M_mathrmy and F_z, based on the WSU- and LSTC-material models, ar... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the failure of the sensor measuring the bending moment (M_mathrmy) during high-speed vertical impact tests affect the accuracy and reliability of injury predictions in the FEM simulations of the Hybrid III dummy? |
Quantitative comparisons of the measured peak responses and the responses predicted by the models are shown in Table 4. Both the predictions of LSTCand the WSU-material models over predicted the peak bending moments and the axial forces. For the peak bending moment, the LSTC model over predicted the test data by 55 for... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How can the overestimation of peak bending moments and axial forces by biomechanical models, such as the LSTC and WSU-material models, impact the accuracy of injury risk assessments in crash simulations? |
Importantly, the prominent double peaks seen in the experimentally measured axial forces were not captured by either the LSTC or the WSU model. The second peak observed in the high-speed whole-body testing is believed to have been caused by a second contact between the foot and the footplate. The first peak was produce... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the stiffness of knee and hip joints in finite element models (FEM) compared to physical dummies impact the accuracy of predicting injury mechanisms, particularly with regard to multi-peak force events during high-speed impacts? |
The object of the current study was to develop a new calibration method for material properties, characterize the rate dependencies of ATD materials under high-speed loading conditions, and evaluate results. The LSTC Hybrid III whole-body FEM, which has never been validated against experimental test data under high-spe... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | What are the implications of the observed discrepancies between experimental data and the enhanced LSTC Hybrid III whole-body FEM predictions for improving injury risk assessments under high-speed vertical loading conditions? |
Efforts were made to ensure that boundary conditions in tests for both component and whole-body levels were kept well controlled and consistent. In all tests, steel rods were used for solidly affixing ATD parts to the test fixture. In the foot impact tests, the ankle was fully affixed to a steel rod, and the centers of... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the alignment of the impactor with the tibia center in leg impact tests affect the accuracy and reliability of tibial injury assessment in biomechanical evaluations? |
Discrepancies between FEM results and experimental data were much larger for whole-body testing than for component-level testing. Joint rotation is believed to have been the major cause of these discrepancies. Unfortunately, high-speed video was not used to capture the events, which would have allowed a depiction of th... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might variations in joint kinematics during high-speed impacts influence the accuracy of injury prediction models in whole-body versus component-level testing? |
No compensations for effects of inertia were made for experimental testing or simulations. The load cells used in the component-level experimental tests (heel-pad foam, foot, and lower leg) were all mounted on the fixed side. Therefore, no inertia compensation was needed. In the whole-body tests, no in-line acceleromet... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the limitations in accounting for inertial effects in both experimental testing and simulations potentially impact the accuracy of biomechanical injury assessments, particularly in the context of high strain rate scenarios such as mine-blast conditions? |
An optimum solution is a set of values to the variables of interest that, together, are as good as or better than any other set of values. Selection of initial values for these variables may lead to a solution that is optimum in a local area, but not globally optimum. If the design space is sufficiently large, results ... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the choice of initial values in biomechanical modeling influence the accuracy of injury assessments, and what strategies can ensure that the optimization leads to globally accurate predictions of tissue responses under impact? |
In future studies, structural parameters such as joint stiffness, will be analyzed. For other future work, it would be interesting to apply high-speed vertical loading to more complex, instrumented ATD legs, such as Thor-Lx (Choi et al. 2005) and Mil-Lx (Pandelani et al. 2010). Further investigation of these legs for A... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How might the optimization method proposed in the study be used to characterize the material properties of more complex instrumented ATD legs, such as Thor-Lx and Mil-Lx, under high-speed vertical loading, and what implications could this have for understanding injury mechanisms in AV-mine detonation scenarios? |
In the current study, three materials (heel-pad foam, foot skin, and lower-leg flesh) taken from the lower extremity of the Hybrid III crash dummy were tested and calibrated. Specifically, the heel-pad foam was tested through a standard uniaxial compressivetesting protocol at the strain rates of 0.01, 0.1, 1, 10, 140 a... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How do the calibrated material models for heel-pad foam, foot skin, and lower-leg flesh in the Hybrid III crash dummy contribute to more accurate injury assessments during full-body vertical loading scenarios? |
Papers must be written in an objective, scholarly, and scientific manner, and must be free of commercialism, advertisement, and product identification. All papers must be written according to conventional English usage. Authors whose first language is not English should have their manuscript edited before submission an... | 2015_Stapp Car Crash Journal Vol. 59(1)_content_list_text.csv | How does the requirement for objective, scholarly, and scientifically written papers, free from commercialism and advertisement, impact the integrity and reliability of injury biomechanics research findings? |
The scope of material contained in this journal includes new data on the biomechanics of injury and human tolerance, new methods and tools to study the biomechanics of injury, new developments in occupant protection systems, and new concepts on the biomechanics of injury based on experimental and analytical studies. Pa... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do new developments in occupant protection systems leverage advancements in the biomechanics of injury to enhance human safety during vehicular collisions? |
where Z_a is the value 1.23 taken from Normal Distribution Table A-1 of Lipson and Sheth (1973) for the median rank value (0.1091) of delta25_mathrmL . Note that the value of Z_a will not change when scaling the sternal deflections of the 25 year-old Mid-Size Male to other sizes or other ages since the median rank valu... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the constancy of the median rank value for sternal deflection (Z_a) influence the accuracy and applicability of scaled risk curves in predicting thoracic injuries (mathrmAISgeq3) across different age and size demographics in biomechanical models? |
NASS files contain thoracic injury risk data of unbelted drivers of various ages involved in frontal collisions in cars equipped with two types of steering wheelcolumn restraint systems, 1) padded steering wheel hubenergy absorbing (EA) column systems and 2) steering wheel airbagEA column systems. The first systems wer... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What are the biomechanical differences in injury outcomes for unbelted drivers in frontal collisions when comparing padded steering wheel hub-energy absorbing column systems with steering wheel airbag-energy absorbing column systems? |
A previously published six-parameter shape model of the central axis of human ribs was used. It has been shown to accurately model the overall rib path using intrinsic geometric properties such as size, aspect ratio, and skewness, through shapes based on logarithmic spirals with high curvature continuity. In this study... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of a six-parameter shape model based on intrinsic geometric properties influence the accuracy of predicting rib fracture risk under different mechanical loading scenarios? |
Regression models of rib stiffness found that all shape model parameters added information when predicting stiffness under each loading condition, with their linear combination able to account for 95 of the population stiffness variation due to shape in midlevel ribs for free axial loading, and 92-98 in other condition... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can understanding the variation in rib stiffness due to shape parameters improve the accuracy of injury prediction models in various loading conditions? |
The thoracic skeleton plays a vital role in protecting occupants in motor vehicle crashes (MVCs), and it is also one of the most frequently injured segments of the body. Within the thorax rib fractures are the most common skeletal injuries in MVCs (Kent 2008, Abdulrahman 2013), and are found in multiple crash configura... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can biomechanical models be improved to better predict rib fracture patterns and their associated physiological complications in various motor vehicle crash configurations? |
Thoracic injury criteria are typically related to measures of chest compression. In most cases this deflection is measured at the sternum and thus is most sensitive to body-anterior loading similar to that experienced by occupants in frontal impacts (for summary see Kent and Patrie, 2005). In lateral impact scenarios, ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in impact conditions, such as arm position and the size and shape of the impacting surface, influence the assessment of thoracic injuries in lateral versus frontal impact scenarios? |
The biomechanical response of the chest and ribs to loading has been investigated at multiple scales ranging from full body or thorax testing to individual component or material tests. At each scale, some degree of variability in response comes from the individual variation between subjects or components being tested. ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the variability in localized geometric properties and bone material composition of ribs affect the accuracy of biomechanical models in predicting injury outcomes during chest loading scenarios? |
A parametric model of in-plane human rib geometry has been developed that accurately quantifies overall rib shape (Holcombe 2016). Its six parameters act both as measures of overall size and shape, while also providing a mechanism to fully create a ribs shape from the parameters alone. It uses intrinsic geometric prope... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the parametric model of in-plane human rib geometry, with its six parameters that define size and shape, be utilized to improve the accuracy and reliability of injury risk assessment in biomechanics? |
(2016) to include the relative influence of each of its parameters (or combinations thereof) on the structural stiffness of rib shapes. Doing so enables researchers to better stratify ribs that are used in physical tests by accounting for variation in stiffness outcomes that come as a result of different rib sizes and ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in rib size and shape influence the structural stiffness under different loading conditions, and what implications might these variations have for predicting rib fracture risk in biomechanical injury assessments? |
All overall rib geometry in this study was represented using a six-parameter shape model that characterizes the central axis of human ribs with a pair of logarithmic spirals (Holcombe 2016). In this study the terms distal and proximal (to the spine) will be used to refer to directions along ribs. A depiction of the mod... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the logarithmic spiral-based six-parameter shape model of rib geometry contribute to improving the accuracy of biomechanical simulations for injury assessment, particularly in terms of predicting fracture patterns or locations on the ribs relative to proximal and distal regions? |
A finite element (FE) modeling system was set up in LS-Dyna (LSTC, Livermore, CA) for any given ribs in-plane shape defined by values from the sixparameter shape model. The goal of the system was to retain sensitivity to overall rib shape which was modeled directly by approximating all other aspects of geometry and m... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of a simplified finite element model of rib geometry and material properties impact the accuracy of injury prediction in biomechanical assessments, and what are the potential limitations of this approach in capturing the variability of real-life rib fracture patterns under different impact conditions? |
In axial loading conditions rib ends were constrained against out-of-plane rotations (but free to rotate inplane). Only translation of the distal end along the ribs local x-axis was permitted and nodal displacement was applied in this direction. For the constrained axial loading condition, a rigid and frictionless fixe... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the constraint against out-of-plane rotations in axial loading conditions impact the mechanical behavior of ribs and their susceptibility to fractures under different loading scenarios? |
Rib stiffness was defined by the initial slope of the force vs. displacement relationship during loading. In axial loading, the reaction force (mathrmF_x) and displacement (Delta_mathrmx) in the mathbfX -direction at the distal rib end up to Delta_mathrmx5 mm were used. For lateral loading, the rigid wall reaction forc... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might variations in rib stiffness, as defined by the initial slope of the force vs. displacement relationship, impact the assessment of injury severity in different loading scenarios such as axial and lateral impacts? |
As validation that the model adequately combined these influencing parameters to produce realistic stiffness magnitudes, a comparison was made between magnitudes found from experimental tests on a population performed by Agnew et. al (2015) and computational tests using our methodology (Holcombe 2016). For consistency ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the comparison of rib stiffness across different studies and methodologies contribute to improving the accuracy of biomechanical injury models, particularly in predicting rib fractures in various populations? |
Overall stiffness results by rib in general followed a log-normal distribution, with the stiffness of shorter 1mathrmst and 12mathrmth ribs in axial loading, for example, being considerably higher than other levels. Overall trends by rib level in each condition are given in Figure 6 using log transformed stiffness valu... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the variations in rib stiffness across different rib levels and loading conditions, as described in the text, influence injury mechanisms and potential risk factors in automotive crash scenarios? |
Using pooled data from mid-level ribs 48, the ability of the rib shape parameters to predict resulting stiffness variation was tested. This mid-level subset of ribs was used in order to correspond to previous testing selection criteria (Agnew 2015). These rib levels also exhibit an overall similar topology and size ( 8... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the variation in mid-level rib shape parameters influence the stiffness of the ribs under different loading conditions, and what implications could this have for injury assessment in biomechanical contexts? |
Ribs from all subjects were stratified by their stiffness under each individual loading condition, and separated into groups from least to most stiff. Averages for each of the six rib shape parameters were calculated from within groups, and are provided in Tables A1 through A4. These data are passed directly to the rib... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might variations in rib stiffness, as stratified by the rib shape model, impact the assessment of rib fracture risk under different loading conditions? |
In free axial loading (Figure 7, top), stiffer ribs tend to have shorter end-to-end spans (lower boldsymbolmathrmS_x parameter), and greater aspect ratio (lower mathrmY_Pk, ). These trends are reflected by the coefficients for boldsymbolmathrmS_x and mathrmY_mathrmPk from Table 1 both being negative in sign. Under cons... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do differences in rib stiffness and geometry, such as aspect ratio and peak skewness, impact the assessment of rib fracture risk and injury severity under both free and constrained axial loading conditions? |
Exemplar von Mises stress distributions at 5mathrmmm or 2 mm displacement in each of the loading conditions are shown for typical 6mathrmth ribs in Figure 9. Maximum stress location was determined for each simulated rib at discrete element locations arranged from the proximal or vertebral end mathrm0 along the rib arc ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the exclusion of local stress concentrations at the contact site in rigid wall loading configurations affect the accuracy of injury assessment in ribs, and what implications might this have for understanding fracture risk? |
Across the full population, the maximum stress location under free axial loading was invariably within a short distance 2 of overall rib length) from the apex of the rib. Due to the differing shapes for each rib level, this was between 40-55 of the arc length for ribs 2 and 3, and occurred progressively earlier for suc... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the stress distribution patterns observed under different loading conditions influence the likelihood of rib fractures at various rib levels, and what implications might this have for designing protective equipment or interventions to prevent thoracic injuries in high-impact scenarios? |
Simulated mechanical loading was performed for a large population of rib shapes from live adults extracted from CT image data. The subject group was chosen so as to adequately represent the breadth of demographics seen throughout the population. An efficient parametric model produced a simplified representation of the ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the parametric model used in this study to represent rib shapes enhance the accuracy of predicting injury risk in diverse populations during biomechanical assessments? |
The free axial loading condition used in this study was chosen to match the framework set forth in Charpail et al. (2005) which has since been adopted in multiple experimental studies (Kindig 2011, Li 2010, Agnew 2015). While not duplicating boundary conditions from an intact human thorax, this framework aims to model ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the use of potting cups and rigid node fixation in the experimental setup impact the biomechanical response of ribs during frontal impact loading, and what implications could this have for accurately assessing rib injury mechanisms in real-world scenarios? |
The constrained lateral loading condition represents a primarily lateral load to the body, but with a sufficient anterior component to prevent anterior rib displacement. The free lateral loading setup is less likely to be experienced in vivo due to the presence of costal cartilage and the sternum, but it tests a rib th... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the presence of the costal cartilage and sternum in a free lateral loading setup influence the biomechanics of rib fractures compared to real-life scenarios, and what implications does this have for injury assessment models? |
Each loading scenario measured stiffness to a differing set of loading conditions, however there were similarities between conditions and they were not fully independent. Log-transformed stiffness results from free axial displacement of rib 6 could explain 57.5 of the stiffness variation under constrained axial displac... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the correlation between stiffness under constrained axial and lateral displacement conditions impact the assessment of rib injuries, and what does this suggest about the predictive value of biomechanical models in these scenarios? |
Results from this study suggest that overall shape does influence the position of maximum stress as a function of overall arc length, however this position varies across the population by around 10-15 of the ribs length, and primarily tracks key locations such as the rib peak. In free axial loading, stress is distribut... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the variation in cortical thickness or other regional material properties of ribs influence the likelihood and location of fractures under different loading conditions, as compared to the influence of overall rib shape? |
An important factor to consider when generating new rib geometry from statistical operations on parameter values is whether the resultant rib shapes are indeed representative of the underlying group. One benefit of the shape model used here is its reliance on intrinsic geometric properties (size, aspect ratio, etc.). T... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in rib geometry, as derived from statistical shape models, influence the biomechanics of ribs under axial loading and potentially impact their injury risk in real-world scenarios? |
Each of the four regression models presented in Table 1 contain all six rib shape parameters as predictors. To assess the information content provided by different parameters both backwards selection and forwards selection models were calculated (using Akaike Information Criterion), and each resulted in this full inclu... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the understanding of rib shape parameters and their contribution to the prediction of stiffness influence injury risk assessment and prevention strategies in individuals exposed to high-impact forces? |
Within any given set of physical experiments whereby ribs are tested for their structural stiffness there will always be some degree of variability. Researchers are most often interested in identifying trends within this variation. Agnew et. al (2015), for example, assessed age as a predictor of mechanical response in ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might integrating rib shape model parameters into biomechanical assessments improve the accuracy of predicting injury risk in the elderly population, considering the variability in structural stiffness with age? |
This study is designed specifically to isolate changes in mechanics that are driven purely by overall rib shape, and this limitation should be taken into account when interpreting its results. For example, the authors do not intend this work to provide a reference for absolute stiffness or indeed the precise location o... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the exclusion of factors other than rib shape, such as bone density or muscle attachment, affect the study's ability to accurately predict injury risk in real-world scenarios? |
In terms of overall shape, it should also be noted that the shape model used describes only the in-plane geometry of ribs. Ribs are known to also deviate from a fitted plane by up to 8 of a ribs end-to-end span (Kindig 2013). It would be expected that greater outof-plane deviation would serve to reduce stiffness to a s... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does incorporating out-of-plane deviations in rib centroidal path models influence the biomechanical assessment of rib stiffness and fracture risk during various loading conditions? |
Future efforts can also be directed at understanding the role that age and other demographic factors play in determining mechanical response of ribs to loading. Mechanical responses such as stiffness to loading are a physical aggregation of multiple different geometric and material factors. Age is known, for example, t... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might demographic factors such as age and rib geometry influence the assessment of rib fracture risk in different populations? |
Ribs from a large population of live adults were characterized using a rib shape model fitted to geometry extracted from CT scans. The subject group was chosen so as to adequately represent the breadth of demographics seen throughout the population. Simulated loading under simplified conditions was applied in one loadi... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the variability in rib shape, as characterized by a rib shape model from CT scans, influence the mechanical properties and subsequent injury risk assessment of ribs under different loading scenarios? |
Subsets and Splits
No community queries yet
The top public SQL queries from the community will appear here once available.