content stringlengths 500 1.99k | filename stringclasses 5
values | Q stringlengths 0 342 |
|---|---|---|
The typical abdominal loading duration, i.e. less than 100 milliseconds, is not compatible with standard imaging modalities such as MRI. As an alternative, Howes et al. (2012, 2015) used high-speed biplane xray imaging (1000 images per second) to follow radio opaque targets implanted in abdominal soft tissues (e.g. liv... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the limitations of high-speed biplane x-ray imaging, such as the need for inferring organ responses from target trajectories and the invasiveness of implanting radio opaque targets, impact the accuracy and reliability of biomechanics injury assessments in abdominal impacts? |
More recently, a new experimental method based on ultrafast ultrasound imaging (Bercoff et al. 2004) was proposed to study the deformation of soft tissues during an impact without the need to implant targets (Helfenstein-Didier et al. 2015, 2016). The approach is complementary to Howes et al (2012, 2015) as tissues can... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might ultrafast ultrasound imaging contribute to the development of more accurate human body models for predicting internal organ responses during blunt impacts, and what implications could this have for improving injury assessment strategies in biomechanics? |
Four unembalmed PMHS obtained from the Department of Anatomy of Lyon 1 through the voluntary body donation to science program were tested using a protocol similar to the one described in detail in Helfenstein-Didier et al. (2016). All tests and procedures were in line with the French ethical rules and the law that allo... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the combined results from both the current study and Helfenstein-Didier et al. (2016) enhance our understanding of biomechanical responses in PMHS, and what implications does this have for improving injury assessment protocols? |
Abdominal Preparation. Before the preparation, the PMHS were thawed at room temperature for 48 hours. To access the abdominal organs, a vertical incision (approximately 10;mathrmcm long) was made on the linea alba in the umbilical region. The largest gas pockets visible in the small intestines were first emptied using ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the preparation and manipulation of the gastrointestinal tract in PMHS contribute to understanding the biomechanical response of abdominal organs to dynamic loading scenarios, such as those experienced during vehicle collisions or other traumatic events? |
Lung Inflation. Helfenstein-Didier et al. (2016) reported a possible case of air migration to the abdominal cavity when pressurizing the lungs. Such migration would be critical as it would prevent ultrasound imaging. For the PMHS 2013-S118, Helfenstein-Didier et al. (2016) inserted two bicycle tire inner tubes in the t... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the application of sealant materials like liquid latex and bituminous spray between the parietal pleura and the diaphragm influence the biomechanics of lung inflation and prevent injury through air migration in post-mortem human subjects (PMHS)? |
For the PMHS 2014-S152 and 2014-S194, the lungs were inflated using a manual air pump and the diaphragm position was held up to the test time using the ultrasound image for visual feedback. The inflation resulted in a small caudal motion of the diaphragm that improved the liver visibility on the ultrasound image. For t... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the method of lung inflation and diaphragm stabilization using ultrasound imaging influence the biomechanical analysis and injury assessment of abdominal organs during testing? |
Overview. The PMHS were seated and fixed onto a metal frame using screws inserted in the spine and ratchet straps around the pelvis and the shoulders. All tests were conducted in a fixed-back configuration with the PMHS in an inverted position as in Howes et al. (2012, 2015). Besides reasons provided by Howes et al. (2... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the inverted positioning of the PMHS, as employed in the study, influence the biomechanical response and injury assessment outcomes during impact testing? |
Each PMMHS was subjjected to up to 25 abdomminal impacts. TThe test seriess was organizeed as presentedd in the Tablee 2. The firsst region of interest was the descendinng colon, folloowed by the liver. The strroke was limiited to less than 30 off the abdomminal thickness in an attemptt to avoid majoor internal injuury... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the increase in abdominal compression from less than 30% to over 40% impact the likelihood and severity of internal injuries in the descending colon and liver, and what biomechanical parameters are most critical in assessing these changes? |
FFor the currentt study, the annalysis was foccused on the liiver tests withh limited stroke. For these teests, impacts wwere deliveredd to the right oof the lumbar spine in the sagittal plane ((approximatelyy at mid distannce between thhe mid sagitttal plane andd the right sside of the aabdomen) ussing a riggid impact... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the location of impact in the sagittal plane, specifically to the right of the lumbar spine, influence the biomechanical response and potential injury to the liver during an impact test with a rigid impactor? |
Ultrasound Probe Positioning. An illustration of the probe placement is provided in Figure 2a. Just prior to the liver tests, the two right floating ribs were surgically removed in order to facilitate the imaging. Then, an ultrasound probe was positioned in the back of the surrogate at the rib removal site. In order to... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the removal of the two right floating ribs impact the biomechanical assessment of liver and diaphragm positioning and function during ultrasound imaging in terms of both accuracy and potential risk of injury? |
Video cameras ( 1024mathrmx1024 pixels, FASTCAM SA3, Photron, Tokyo, Japan) equipped with zoom lenses (SIGMA 24-70ensuremath,mathrmmm , 1:1:8, EXDG, Tokyo, Japan) filmed the tests at 2000 frames per second. Two cameras provided side and oblique views of trunk and impactor. A pair of cameras filmed the back of the surro... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the integration and calibration of high-speed video cameras from multiple angles enhance the accuracy and reliability of biomechanical analyses in assessing the dynamic interaction between seatbelt systems and human surrogates during high-impact scenarios? |
The piston force was measured using a 22mathsfk N load cell (Humanetics, 10485FL). For impactor loading, two accelerometers (ENTRAN, GV512 and GV2510) were used for the inertial compensation with different ranges ( 50mathrmg and 250mathrmg . The 50mathrmg accelerometer was only used for tests with the PMHS 2014-S152 bu... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the differences in accelerometer ranges (50g versus 250g) impact the accuracy and reliability of inertial compensation during impactor loading tests, particularly in assessing injury thresholds in biomechanical studies? |
The time of contact between the impactor and the PMHS was determined based on video data. The penetration was derived from the piston displacement except for the PMHS tested by Helfenstein-Didier et al. (2016) for which video tracking was used. For seatbelt loading, markers placed on the seatbelt were tracked in 3D (Vi... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of different filtering techniques for impactor forces and displacements affect the accuracy and reliability of injury assessment in biomechanical testing? |
The 50mathrmth male GHBMMC model verrsion 4.4 (Gloobal Human BBody Models CConsortium, wwww.ghbmc.coom, mathrmM50mathrmv4.4) was used for the study. Inn order to redduce the possiible effects oof PMHS sizee (Table 1), the model waas scaled to mmatch the heighht and abdomminal thickness (measured att the umbilicuus) of ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the scaling of the 50th percentile male GHBMC model to match the anthropometric dimensions of PMHS contribute to more accurate injury assessment in biomechanical studies? |
Trajectoriies of nodes correspondinng to the featture points wwere used tto compare simulation and experimenntal results. TThe nodes werre selected baased on the disstance of the ffeature point tto the diaphraggm, the anterrior skin andd the lateral skin. Trajecttory parameterrs were calcuulated as in the experimeents.... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in impact position affect the distribution of strain energy density within the liver, and what implications might this have for predicting liver injury risk in scaled biomechanical models? |
All PMHS were subjected to impactor loading and some to belt loading with a limited stroke and without perfusion. These tests were followed by the perfusion of the PMHS and tests with an increased stroke. However, based on pre-test ultrasound images, the perfusion seemed to have little or no effect on the liver despi... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the methodology of perfusion affect the integrity and mechanical response of soft organs, such as the liver, during impactor and belt loading tests in PMHS experiments? |
Impactor Loading. An illustration of an upper abdomen impactor test including both external and internal views, and pre- and post-test B-mode images is provided in Figure 5. The liver is highlighted in the figure. Its motion is clearly visible as the impactor compresses the upper abdomen. However, the impactor was typi... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the visibility of the liver and diaphragm during the upper abdomen impactor test contribute to understanding the biomechanical response and potential injury mechanisms of these organs under impact conditions? |
Sagittal target trajectories derived from the ultrafast ultrasound images are summarized in Figure 6 for all PMHS. Response time histories for each surrogate and for each test are provided in Appendix B. Overall, the trajectories appeared like loops that are more or less rounded depending on the PMHS. After a first par... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the variations in the sagittal target trajectories, as depicted in Figure 6, influence the assessment of injury risk and the development of biomechanical models in post-mortem human subjects (PMHS) during impact tests? |
Motion amplitudes along X ranged from approximately 5 to 25mathrmmm (Figure 7a), and for each PMHS, they were higher when the impactor was aligned with the liver and then decreased when the impactor was moved away caudally. The impactor position around 100;mathrmmm caudal to the diaphragm was associated with the highes... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the variability in displacement amplitudes along the X and Z axes, as well as the time delay to peak excursion, affect the assessment and prediction of liver injuries in post-mortem human surrogates (PMHS) when exposed to impactor forces aligned at various distances from the diaphragm? |
For the impactor force (available for four PMHS), an example of response is provided in Figure 8a, and all time histories are provided in Appendix B. Peak impact forces ranged from less than 100N to approximately 800N (Figure 8b). The peak force had a tendency to decrease as the distance between the impactor and the di... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical factors could explain the observed decrease in peak impactor force as the distance from the impactor to the diaphragm increases, and how might these factors influence injury assessment in similar impact scenarios? |
Seatbelt Loading. An example of belt penetration and belt force time histories is provided in Figure 9a. All time histories are provided in Appendix B. The peak impactor forces were higher than in the rigid impactor tests (Figure 9b) although the peak belt penetrations (Table 8) were smaller than the impactor penetrati... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do differences in belt penetration and impactor force influence the biomechanical injury response, specifically in terms of internal organ displacement and potential for injury, as observed in the trajectories of liver feature points? |
Not all impactor tests could be simulated with the human model. In some cases the anatomical position of the PMHSs liver (e.g. 2016-S111, high in the ribcage, see Figure 1) allowed performing tests up to distances between the diaphragm and the impactor which could not be reproduced with the human model as the impactor ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in anatomical positioning of organs, such as the liver, affect the accuracy and reliability of impactor tests in human biomechanical models compared to PMHS (Post-Mortem Human Subjects) assessments? |
An example of force time history is provided in Figure 15 along with the summary of the peak forces. Forces were generally higher in the simulations than in the experiments. The smallest difference was obtained for the PMHS 2016-S118 (male PMHS, slightly larger than an average male), with a difference between simulated... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the discrepancy in force measurements between simulations and experiments, particularly the significant variance observed in small female PMHS, impact the reliability of predicting injury outcomes in biomechanical assessments? |
Experimental Results. Four PMHS were tested using ultrafast ultrasound imaging to observe the internal kinematics of the liver during abdominal loading. The results were analyzed together with a fifth PMHS tested in a previous study. Trajectories of feature points of the liver could successfully be followed semi-automa... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the semi-automatic tracking of liver feature points during abdominal loading impact the reliability of injury assessment in post-mortem human subjects (PMHS), and what improvements could be achieved by utilizing specialized methods for ultrafast ultrasound images? |
The trajectories were mostly like rounded loops, similar to the results of Howes et al. (2012) but the motion amplitude was smaller in the current study. The analyses of the trajectory suggest that the initial direction of the liver motion (angle) and the amplitude of X displacement are very sensitive to the distance b... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the sensitivity of liver motion trajectory parameters to the position of the impactor, as observed in this study, influence the assessment and modeling of abdominal injuries in biomechanical research? |
A free-back test configuration could be more representative of the loading experienced by vehicle occupants. However, tests were conducted in a fixedback configuration for multiple reasons. A fixed-back configuration prevents large motion of the ultrasound probe during the impact which would make the analysis much more... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the fixed-back configuration in impact testing influence the assessment of injury risk and biomechanics compared to a free-back configuration, especially when analyzing the abdominal region during vehicle collisions? |
The studyy of the effecct of the loadding location aalso required performing nnumerous tessts on the saame PMHS. CConsidering thhe duration neeeded for the teests, these tests were performmed without pperfusion to avvoid excessivee diffusion of ffluid in the tisssues (Helfenstein et al. 20012). This is likely to haave ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the lack of perfusion during the initial tests on PMHS (Post-Mortem Human Subjects) impact the injury biomechanics of the organs, specifically in terms of tissue response and potential damage, especially when considering the cumulative effects of repeated testing? |
Two PMMHS were noot inflated. Thhe lack of lung inflation ccould have afffected the diaaphragm and liiver position, and perhaps the initial sttrain state of the diaphragmm and the resiistance to liveer cranial motiion. While the position off the liver waas measured, the effects off the other facctors are largelly unkno... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the absence of lung inflation influence the biomechanical stress distribution and potential injury mechanisms in the diaphragm and liver during impact scenarios? |
The strokke was limiteed to avoid mmajor soft tisssue damage in repetitive testing. Thiss seemed to be effective as despite thee more strenuoous final loadiing, soft tissuue injuries w were relativeely limited. Rib fractures could not be avoided howeever, and the fact that fractuures cannot bee associated too specific ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does bone quality influence the propensity for rib fractures in PMHS subjects with different body masses during biomechanical impact testing, and what implications does this have for accurately assessing injury risk across diverse physical profiles? |
WWhile the effeects of stroke aand velocity ccould not be qquantified in the current study as it wwould have required a largge increase off the number of tests, the results suggestt the current pprotocol couldd be used to study such parrameters. In thhe meantime, tthe few tests pperformed at different speeeds on the PM... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the current testing protocol be adapted to more effectively assess the impact of different stroke velocities on injury biomechanics and what considerations should be made for adequate perfusion in these studies? |
Simulation Results. In the simulations of the impactor tests performed with the GHBMC M50 model, some of the overall trends observed in the experiments could be reproduced. These include in particular the sensitivity (i.e. slope) to the position of the trajectory angle, peak X displacement response and corresponding Z ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the implementation of improved contact modeling techniques, or reducing sliding contact gaps, potentially enhance the accuracy of displacement amplitude predictions in biomechanical simulations like those with the GHBMC M50 model, thereby influencing injury assessment outcomes? |
the caudal motion of the diaphragm pulled by the ribs or abdominal wall during the compression; the elastic return of structures such as the diaphragm or the liver (constrained by the diaphragm); the contribution of the hollow organs: these are initially applying their weight onto the liver due to the inverted position... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the caudal motion of the diaphragm, influenced by the ribs or abdominal wall during compression, impact the biomechanical assessment of liver injury in scenarios involving an inverted position? |
Also, the model was globally scaled using anthropometric dimensions derived from the height, weight and abdominal thickness based on the ANSUR database. This does not take into account the geometrical and anatomical specificities of each PMHS. More specifically, the model was scaled to match the abdominal thickness of ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the discrepancies in scaling of soft tissues and anatomical positioning in biomechanical models affect the accuracy of injury assessment and predictions in the thoracic and abdominal regions? |
All simulations were performed as if the ribs were not fractured. When analyzing the impact force and kinematic results, it is important to remember that the strokes were close but not exactly the same for a given PMHS, and that the same stroke may correspond to different compression levels depending on the impact loca... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might variations in thorax and abdomen thickness, as observed in the PMHS, influence the accuracy of biomechanical simulations in assessing the risk of rib fractures and other thoracic injuries during impact events? |
Finally, the liver strain energy densities predicted by the model were also found to be widely affected by the distance between the diaphragm and the impactor, and by the PMHS simulated. Differences between simulated PMHS may be attributable to differences of compression levels and the relative size of the scaled liver... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the relative positioning of the impactor and the organ affect the predictive accuracy of strain energy density as an indicator for liver injury in biomechanics models, and what implications does this have for selecting tolerance levels in simulations based on historical PMHS tests? |
A protocol based on ultrafast ultrasound imaging was applied to study the in situ motion of the liver while the abdomen was subjected to loading by a hemispherical impactor or a belt positioned in various locations along the cranial caudal axis. Trends were found between initial impactor location and liver trajectory p... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can ultrafast ultrasound imaging be utilized to accurately assess liver motion and potential injury risk during abdominal impacts, and what role does the initial impactor location play in these assessments? |
ABSTRACT Past studies have found that a pressure based injury risk function was the best predictor of liver injuries due to blunt impacts. In an effort to expand upon these findings, this study investigated the biomechanical responses of the abdomen of post mortem human surrogates (PMHS) to high-speed seatbelt loading... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What advancements in pressure-based injury risk functions for abdominal injuries can be derived from the data on peak forces, penetrations, and vascular pressures observed in PMHS during high-speed seatbelt loading? |
Several studies have used post mortem human surrogate (PMHS) testing to investigate the biomechanical response of the abdomen to belt loading. Hardy et al. (2001) performed a series of PMHS tests to study the biomechanical response of the abdomen. The findings from this study were used to develop force-penetration corr... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the initial lateral contact of a seatbelt affect the biomechanical response and stiffness of the abdomen in post mortem human surrogate testing, and what implications does this have for improving safety belt design and injury prevention in real-world scenarios? |
Several studies have investigated various metrics for their association with abdominal injuries. In 2010, Rouhana et al. reviewed and analyzed various studies of abdominal seatbelt loading which featured pretensioners. They used the Ford Human Body Finite Element Model and data from published PMHS tests to develop AIS ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the Abdominal Injury Criterion (AIC) developed by Rouhana et al. effectively predict abdominal injury risk in scenarios involving seatbelt pretensioners, and what implications might this have for improving current injury assessment methods using biomechanical models? |
While several studies to date have shown AIC to be a very good predictor of injury, other studies have focused on other metrics such as pressure. Sparks et al. (2007) conducted bench-top tests on ex-vivo human livers which revealed a correlation between vasculature pressure changes and injury. Kremer et al. (2011) cond... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the peak rate of pressure change in abdominal vasculature be effectively used to predict liver injury risk in seatbelt loading conditions, and what biomechanical factors need to be considered in this scenario compared to blunt impacts? |
A seatbelt loading device similar to the one developed by Hardy et al. (2001) was used to simulate the behavior of a belted occupant in a frontal crash. The device used a pneumatic piston to pull a seatbelt into the abdomen of a PMHS in a controlled, dynamic scenario. The test fixture utilized pressurized nitrogen to p... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the mechanical setup used in this experiment, particularly the dynamics of the pneumatic piston and T-bar seatbelt mechanism, impact the accuracy of assessing abdominal injuries in PMHS during simulated frontal crashes? |
Internal instrumentation included pressure transducers (Millar instruments, TX, Model SP-524) attached to angiographic catheters routed through Foley catheters. The pressure transducer assemblies were inserted into the abdominal aorta and IVC. To re-pressurize the abdominal region of each PMHS, Foley balloons in the ve... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the placement of Foley balloons in the abdominal aorta and inferior vena cava influence the assessment of vascular injury and pressure distribution in post-mortem human subjects (PMHS)? |
The pressure transducers were then inserted into the vasculature to record pressure during the event. The pressure transducer locations included the superior IVC, inferior IVC (intersection of left and right common iliac veins), superior abdominal aorta (celiac trunk) and inferior abdominal aorta (intersection of left ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the dislodgement of pressure transducers during impact events affect the accuracy and reliability of injury assessments in biomechanical studies? |
In order to track skeletal motion, 3a motion blocks consisting of three linear accelerometers (Endevco, CA, Model 7264c) and three angular rate sensors (DTS, CA, Model ARS 8mathrmk ARS-PRO 18k) were attached to vertebrae T8, L2, and L4 using a bridge mount that rested on the pedicles with one screw drilled though the ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the angular rate sensors and linear accelerometers attached to vertebrae T8, L2, and L4 contribute to understanding the biomechanical response of the spine during impact, particularly in identifying potential injury mechanisms? |
Once the instrumentation was complete, a FARO Arm (FARO Technologies Inc., Florida) was used to document subject position in all three dimensions and locate the initial position of the 3a motion blocks. Points taken on the motion blocks along with other reference points on both the T-bar mechanism and the specimen were... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of a FARO Arm and the process of transforming local coordinate data to a global lab coordinate system enhance the accuracy of biomechanical injury assessments, particularly in terms of tracking the kinematics of specimens during experimental procedures? |
Following instrumentation, a pre-test CT scan was done. The CT scan was used to document the locations of the internal instrumentation in addition to identify any pre-existing injuries or post-test damage to the skeleton. Pre-test positioning of the specimen in the seatbelt test apparatus is shown in Figure 4, and a sc... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the pre-test CT scanning process contribute to the accuracy of injury assessment and documentation in biomechanical testing involving post-mortem human subjects (PMHS)? |
The seatbelt was positioned to wrap around the anterior and lateral aspects of the PMHS abdomen at the level of the umbilicus with the belt webbing placed above the iliac crests of the pelvis. The initial belt tension was adjusted so that each belt load cell measured 15substack-20mathrmN , which applied a pre-stiffenin... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the pre-stiffening load of the seatbelt and the re-pressurization of arterial and venous systems affect the biomechanical response of the abdomen during a simulated impact event? |
Data were acquired at a sampling frequency of 20,000 Hz. Each channel of the data acquisition system was anti-alias filtered using a 4th-order Butterworth low-pass filter with a frequency of 2900 Hz at -3dB. After removing bias, all data signals were filtered according to standard SAE-J211 using channel filter classes ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the utilization of a 4th-order Butterworth low-pass filter with a frequency cut-off of 2900 Hz and compliance with SAE-J211 standards influence the accuracy of measuring spinal displacement in biomechanics studies? |
Abdomen penetration was defined as the deflection of the abdomen versus time, where the deflection is measured at the point anterior to the abdomen at the sagittal midline using a string potentiometer attached to the belt. Compression of the abdomen was defined as the percentage of penetration, calculated by dividing t... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the variability in seated abdomen depth due to perfusion of organs and vasculature impact the accuracy of injury assessments in the context of abdominal penetration during biomechanical testing? |
Belt force was calculated as the sum of forces obtained from the two seatbelt load cells. Abdomen penetration speed was found by differentiating abdomen penetration. An equal-stressequal-velocity (ESEV) scaling technique by Eppinger et al. (1976) was used to generate normalized force-penetration responses using a 78mat... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of Eppinger et al.'s equal-stress-equal-velocity (ESEV) scaling technique influence the accuracy of normalized force-penetration responses in predicting abdominal injury risk in a standard midsized male during a vehicle collision? |
Arterial and venous pressure readings in the abdomen were recorded during each PMHS test. None of the pressure values recorded in the aorta have been used in the calculation of the injury risk functions (IRF) in order to be consistent with Kremer et al. (2011) who used only pressure values from IVC locations for IRF co... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the exclusion of aortic pressure measurements in favor of IVC pressure values impact the accuracy and reliability of injury risk functions (IRF) for predicting abdominal injuries, and are there potential biomechanical consequences or limitations associated with this methodological choice? |
An anatomical dissection was performed following the last test of each PMHS to identify skeletal and abdominal damage. The dissection results are tabulated in Table 2 and the organ damages observed are shown in Appendix B. Abdominal damage of AIS ge3 was sustained in three specimens. PMHS01 sustained a splenic fracture... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the location and mechanism of the abdominal soft tissue injuries observed in the specimens, particularly in relation to the belt path, inform adjustments in safety device design to mitigate such injuries in crash scenarios? |
Figure 6 compares the effect of perfusion on PMHS04 and PMHS05. The belt force was higher in the perfused test of PMHS04, whereas, it was higher in the non-perfused test of PMHS05. The tests in which the vasculature was not perfused resulted in smaller peak penetrations. Additionally, a comparison of force and penetrat... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the presence or absence of perfusion in human surrogate models impact the evaluation of injury mechanisms, specifically regarding force and penetration metrics during belt restraint tests? |
Figure 8 shows the force and penetration responses normalized using the ESEV method. The peak forces using the ESEV approach ranged from 3.7 to 5.2;mathrmkN and the peak abdomen penetrations ranged from 124 to 183mathrmmm . The initial stiffness responses were similar between all tests with a tight grouping for test co... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of the ESEV method for normalizing force and penetration data improve the accuracy of injury assessment in biomechanical testing, particularly in developing corridors for Anthropomorphic Test Devices (ATDs)? |
Figure 9 shows the mean force-penetration along with a newly generated corridor based on plus one and minus one standard deviations. The original output from MATLAB is presented in Figure C2. Finally, the corresponding mean penetration vs. penetration speed is presented in Figure 10. Stiffness of the abdomen for each t... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What role does abdominal stiffness, as quantified by the mean force-penetration and penetration speed, play in assessing injury risk during biomechanical testing of post-mortem human specimens (PMHS) under condition A? |
The damage sustained by the seven PMHS in the current study are summarized in Table 2. The majority of damage identified was to the smallintestine. Test PMHS01 resulted in a splenic fracture found medially on the border of the renal and gastric surfaces. It is theorized that the fracture was due to the enlarged spleen ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical factors could contribute to the susceptibility of the spleen to fractures during lateral seatbelt compression in PMHS, and how might these factors complicate injury assessment in the presence of splenomegaly? |
The jejunum damage sustained by PMHS07 was a full thickness, circumferential tear with a length of 0.7 mathrmcm on the non-mesenteric side. The damage was identified in the path of belt loading at the 3rd lumbar vertebral level, surrounded by other intestinal tissue and not in contact with bony structures. Since the bo... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the presence of intestinal contents influence the likelihood and severity of jejunum injury during belt loading scenarios in biomechanical studies, and how can this be accounted for in injury assessments? |
The study by Howes et al. (2012) investigated effects of inverting a cadaver on the thoraco-abdominal contents using biplanar x-ray. The authors found that an inversion of the cadaver can place the thoracoabdominal contents closer to the in-vivo condition and suggested that the mechanical response and injury patterns w... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the inversion of a cadaver alter the biomechanical stress distribution on thoraco-abdominal organs, and what implications could this have for accurately assessing injury risk in both solid and hollow organs? |
PMHS02, 03, and 05 presented transverse processes fracture of the L4, L5 and L3 vertebrae, respectively. During dynamic loading of the abdomen, the PMHS was driven backwards resulting in the posterior aspect of the PMHS colliding against the foam padding attached to the edge of the T-bar. Mounts used to secure the 3aω ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might bone density and body composition influence the risk of vertebral and skeletal fractures during dynamic loading scenarios similar to those described, and what biomechanical factors should be considered to improve injury prediction models in such cases? |
Force-penetration responses were first normalized using the ESEV technique with a reference mass of 78mathrmkg (Figure 8). This method assumed geometric similitude between PMHS and rather than reducing variation in the data, this normalization technique resulted in little change from the original data. It may be argued... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might variations in seated posture and body mass distribution influence the validity of using the ESEV normalization technique for assessing force-penetration responses in injury biomechanics studies? |
While the measurement apparatuses tracking the posterior motion of the specimen were different between the Hardy et al. (2001) and current setups, 3a motion blocks on L2 and L4 in addition to the string potentiometer on L3 provided accurate measurement of spinal movement. This array of instrumentation could be used to ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the integration of multiple motion tracking devices, such as motion blocks and string potentiometers, enhance the accuracy of assessing spinal injuries during dynamic events? |
PMHS04 and 05 were impacted twice to better understand the role of pressurization in the forcepenetration responses. Due to the differences in the calculated stiffness of this work compared to Hardy et al. (2001), it was thought that perhaps a difference in pressurization technique might explain the dissimilarity in st... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does vascular perfusion influence the biomechanical response and injury outcomes in abdominal impacts, and what are the implications for improving injury prediction models in automotive safety testing? |
Comparison to Hardy and Miller data. Figure 13 compares the new mean force-penetration response with plus one and minus one standard deviation to the Hardy belt corridor and plus one and minus one standard deviation adapted from Miller data. One of the primary differences between the Hardy et al. test setup and the cur... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the omission of an outlet solenoid valve in the current study's setup impact the accuracy and reliability of biomechanical injury assessments compared to the Hardy et al. study, specifically in terms of abdominal compression and stiffness measurements? |
The abdomen penetration in the current study shows no direct correlation to penetration speed. Similarly, no discernable correlation exists between abdomen peak penetration and seatbelt peak force. Additional tests with a fixed back setup under various loading rates may provide information of viscous and damping charac... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical factors could explain the absence of a direct correlation between abdomen penetration and penetration speed in the context of injury assessment? |
Foley catheter balloons were inflated at the level of the diaphragm and at the level of L3, just above the bifurcation of the iliac vessels for both arterial and venous systems in an effort to create a closed subsystem for the abdomen. The closed subsystem for the abdominal vasculature in the current study included the... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might variations in pressure readings from different sensors within the simulated abdominal vasculature subsystem affect the accuracy of biomechanical injury assessment during impact tests? |
While the previous studies had set threshold values for predicting liver injuries, adding data from the current study shows that lower rates of pressure change compared to previous findings did not cause serious injuries to abdominal organs. The 50 risk value for the IVC dotmathrmP_mathrmmax reduced to 9.3 mathrmkPams ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the findings from combining data from multiple studies, such as those by Kremer (2011), Sparks (2007), and the current study, refine our understanding of pressure thresholds for abdominal organ injury, particularly in terms of predicting liver injuries in biomechanical research? |
The inclusion of data from Kremer and Sparks with the current study represents a variety of boundary conditions such as direct impact loading to the exvivo liver, rigid impact to the liver via rib-cage and distributed belt loading to the abdomen. Despite such disparate loading mechanisms and speeds, the pressure-relate... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the different boundary conditions, such as direct impact loading, rigid impact via the rib-cage, and distributed belt loading, influence the biomechanical response and risk of abdominal injury in the liver? |
There were tests with skeletal damage but no abdominal damage. While some factors contributing to skeletal damage include bone mineral density (BMD) and subcutaneous tissue thickness, the same factors may not affect soft tissue such as abdominal organs. Table 2 shows discrepancies in skeletal and organ damage to the sa... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical factors could explain the discrepancy between skeletal and abdominal injury outcomes in crash tests, and how might this inform the development of more accurate injury prediction metrics for anthropomorphic test devices (ATDs)? |
The pressure data from the current study by itself does not allow for a standalone metric. The data-sets from ex-vivo and PMHS tests were combined to see if pressure related variables could predict mathrmAIS3 abdominal injury despite the different boundary conditions. Combining the data-sets from ex-vivo and PMHS tests... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanics-based methodologies could be employed to further refine pressure-related variables in predicting AIS3 abdominal injuries, given the significant increase in GKG values when combining ex-vivo and PMHS datasets? |
Although the primary focus areas of this study included mechanical response and damage risk using pressure, some specimens in this study were tested twice. The lack of soft tissue damage in the first three tests provided sufficient confidence to test the remaining specimens more than once. In order to verify if additio... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical mechanisms or factors could explain the increased severity of damage observed in specimens tested twice, despite the lack of observable soft tissue damage in initial tests? |
One challenge of working with PMHS is selecting surrogates that represent real-world occupants while also controlling them to reduce variation due to differences in size and shape. The current study accepted specimens in both normal and overweight BMI categories. It is worth noting that BMI may not be a reliable factor... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of seated abdomen circumference as a selection criterion for PMHS enhance the accuracy of biomechanical injury assessments compared to relying solely on BMI? |
The abdomen is a difficult region of the body to categorize injury risk, largely due to the heterogeneity of the abdominal structure. The organs in the abdominal region may experience injury through different mechanisms depending on the organ. Since pressure was found to be strongly correlated with liver damage in ex-v... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can biomechanical modeling be utilized to better understand the pressure-induced injury mechanisms specific to different abdominal organs, given the heterogeneous nature of the abdominal region? |
Another limitation of this study was the variation in the magnitude of pressure within and between subjects. The inferior pressure sensors in the PMHS07 tests were found during anatomical dissection to be in the path of seatbelt loading, which may have generated a contact induced anomaly. Hence the sensors from these t... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the exclusion of pressure sensor data, due to contact-induced anomalies and variation in vasculature branching, affect the reliability and validity of biomechanical injury assessment in studies using Post-Mortem Human Subjects (PMHS)? |
For all PMHS tests, the inferior Foley catheter balloons were inflated at the level of L3. This location was selected to include all abdominal vessels in the closed subsystem. However, this location was directly in the proximity of loading (belt path) which may have confounded the pressure readings, especially in the P... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the proximity of the inflated Foley catheter balloons to the belt path influence the accuracy of pressure readings in injury biomechanics assessments involving abdominal vessels, and what alternative methods could be employed to mitigate potential confounding effects? |
In test PMHS01, one of the two seatbelt load cells failed, which led to the use of compensated force calculation using the load cell attached to the ram. However, the results from the inertially compensated load cell have been verified to be consistent with the total force from seatbelt load cells. In test PMHS05_2, th... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can redundancy in biomechanics testing measurements, such as force and penetration, improve the accuracy of injury assessment in experimental studies? |
The primary objective of this study was to create a test condition by which to evaluate and improve the biofidelity of the abdomen in ATDs. This objective was achieved as a new biofidelity response corridor was presented. A total of ten tests were conducted on seven PMHS with and without re-pressurized abdominal vascul... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the re-pressurization of abdominal vasculature in PMHS influence the biofidelity response of ATDs during seatbelt loading tests? |
The strongest predictor of abdominal injury was the AIC proposed by Rouhana et al. in 1985, when multiple datasets were combined with data from the current study. The value of mathrmDeltaV_maxC_m a x 3.80;mathrmms (p-value 0.002 and Goodman-Kruskal mathrmGamma0.80) corresponded to a 50 risk of mathrmAIS underline 3 abd... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What specific factors contribute to the predictive power of the Abdominal Injury Criterion (AIC) in assessing the risk of AIS 3 abdominal injuries across different datasets? |
ABSTRACT The aim of this study was to investigate the sacroiliac joint injury mechanism. Two test configurations were selected from full scale car crashes conducted with the WorldSID 50mathrmth dummy resulting in high sacroiliac joint loads and low pubic symphysis force, i.e. severe conditions for the sacroiliac joint... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical factors could contribute to the observed sequence of pubic fractures occurring before sacroiliac joint fractures in the majority of cases during high-load impact scenarios, and how might these factors inform injury prevention strategies? |
The injury severity of the bony pelvis is assessed on two anatomic structures: the pelvic ring and the acetabulum (AAAM 2005). The acetabulum is the part of the pelvis receiving the femur heads. The pelvic ring is formed by the different pelvic bones and associated ligaments and is divided in two arches: the anterior a... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical factors contribute to a higher AIS score for pelvic injuries involving the posterior arch compared to isolated anterior arch fractures? |
In 2012, Petitjean et al. developed a pelvic injury risk curve based on the pubic force using paired PMHSWorldSID dummy matching tests. The injury risk curve was founded on pure lateral impacts only: sled tests on the one hand, and impactor tests on the other hand. The impactor tests used a small radius impactor (diame... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in impact location, such as concentrated loads on the posterior arch versus the anterior arch of the pelvis, influence the stress distribution and injury risk in pelvic biomechanics? |
For that purpose, Petit et al. (2015) conducted a series of nine PMHS impactor tests in three oblique impact conditions resulting in high loading of the posterior arch of the pelvis ring. The test conditions were chosen among full-scale vehicle tests that used the 50mathrmth percentile WorldSID dummy and for which the ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do different orientations and offset configurations of impactor tests influence the risk of injury to the posterior arch of the pelvic ring in comparison to full-scale vehicle tests using the WorldSID dummy? |
On the contrary, the test configurations 1 and 3 induced pelvic rings fracture threatening the pelvis stability. Considering these two test configurations altogether, the main observations of Petit et al. (2015) were: 1) the strain gauges signals glued on the pelvic bone showed that the fractures at the pubic area occu... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the initial occurrence of pubic area fractures compared to Sacroiliac joint fractures impact the biomechanical assessment of pelvic ring stability in different test configurations? |
Each PMHS was seated on a low friction horizontal plane, and was impacted laterally using an impactor. The pelvis was primarily loaded, then the upper body. The lower legs of the PMHS were amputated and the upper legs placed onto the horizontal rigid seat, approximately perpendicular with the direction of impact. The a... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical implications and injury risks are associated with the lateral impact loading of the pelvis and upper body in PMHS when the lower legs are amputated and the body is supported on a low friction horizontal plane? |
The impactor was equipped with three impacting rigid flat plates: one for the pelvis, one covering the thorax and the abdomen, and one for the shoulder. The 3D coordinates of the plates corners in the laboratory coordinate system are given in Appendix B. Only the pelvis plate features varied according to test configura... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the varying orientations and configurations of the pelvis impactor plate affect the potential biomechanical injury outcomes to the pelvic region during impact testing? |
To limit the variability in the pelvis response, a positioning constraint was defined on the Nyquist plane (Nyquist and Murton 1975) for each test configuration. These constraints were derived from the position of the WorldSID pelvis in the FEsimulations and presented in Table 2. The ideal position in front of the pelv... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do positioning constraints on the Nyquist plane affect the biomechanical response of the pelvis in crash test simulations, and what implications might this have for assessing potential injury outcomes in real-world scenarios? |
The impactor was equipped with a three-axis load sensor placed behind the main pelvis plate. The load sensor was attached at the center of the main pelvis plate using eight screws, which can be seen at the front of the main plate in Figure 3. It had the same location for both configurations. For configuration 3, the lo... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of a three-axis load sensor combined with a three-axis accelerometer and a one-axis accelerometer enhance the accuracy and reliability of biomechanical data collection during an impact, and what implications does this have for injury assessment in crash testing scenarios? |
Eleven strain gauges were glued on the pelvic bone as shown in Figure 6. Compared to Petit et al. (2015), two additional strain gauges were glued on the left and right ischio-pubic rami, on the anterior side close to the pubic symphysis. Also, for the tests from MS 695 through MS 706, the upper gauges of the iliopubic ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical implications might arise from repositioning the strain gauges on the iliopubic rami to the outer side of the rami during injury assessment, and how could these changes affect the interpretation of pelvic stress distribution and fracture risk analysis? |
Then, an injury sequence of the pelvic bone was derived from the time of fracture identified on the strain signals. The pelvic bone was divided in four main areas: the sacrum area, the right and left iliac wing area, and the pubic area. The sacrum area included the sacroiliac joints. The time of fracture attributed to ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can strain gauge data be utilized to accurately assess the sequence of fractures in the pelvic bone during an injury event, and what are the implications for understanding the biomechanics of pelvic injuries? |
Test configuration 1 According to Table 7, the PMHS pelvis angles were in general close to the target with an average angle of -45circ and a standard deviation of 1.7circ . The ASIS-PS angle of the PMHS MS-663 presented the furthest deviation (-50circ) . This may due to a displacement of the PMHS between the time when... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might deviations in pelvis angle, such as the one observed in PMHS MS-663, impact the accuracy of injury biomechanics assessments in test configurations, and what measures can be taken to ensure that initial positioning discrepancies do not affect the results? |
Test configuration textit3- According to Table 8, the PMHS pelvis angles were in general slightly off from the target with an average angle of -49circ and a standard deviation of 2.5circ but the coefficient of variation was only 5.1 . However, one PMHS, the MS-693, presented an important difference between the position... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How can the misalignment in ASIS angles observed in PMHS MS-693 affect the accuracy of injury biomechanics assessments, and what strategies can be implemented to improve positioning standardization during testing procedures? |
In the configuration 3, the position of the AnteroSuperior Iliac Spine (ASIS) had an additional constraint in addition to the X and Z targets: it had to remain in front of the offset plate. It means that an adjustment along the Z axis may also induce an adjustments along the X axis, as the offset plate had an oblique i... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the oblique implantation of the offset plate in configuration 3 potentially influence the risk of biomechanical injury to the pelvis, particularly concerning the stability and alignment of the AnteroSuperior Iliac Spine (ASIS)? |
The observation of the films confirmed that the pelvis were always impacted first by the impactor. It defined the time 0 of the impact using the butterfly switch glued on the pelvis plate. The thorax and shoulder impacting plates were not instrumented using butterfly switch. The times of contact of the thorax and the s... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the lack of precise instrumentation for thorax and shoulder impact times affect the accuracy of biomechanical injury assessments in crash scenarios? |
Overview Nine PMHS out of eighteen sustained mathrmAIS2 pelvic injuries. The detailed description of the injuries are given in Table A 5 through Table A 13 in Appendix C. The AIS scores of all the PMHS are gathered in Table 12. In configuration 1, five PMHS sustained mathrmAIS2 injury. In configuration 3, four PMHS su... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the variations in configurations influence the pelvis biomechanical response and MAIS scores, and what insights can be drawn about the specific conditions that lead to AIS2 pelvic injuries? |
AIS coding The stability of the pelvis, which is a criterion in the AIS 2005 score was assessed before removing the surrounding tissues. The details of the pelvic injuries and the rationale for the related AIS score are reported in in Table A 5 through Table A 13 in Appendix C but some particular aspects of the AIS co... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the presence of partial fractures, such as those observed in the left pubic rami and sacral ala, influence the stability assessment of the pelvic structure in the context of AIS 2005 coding? |
The injuries shown in Figure 8 and in Appendix C are summarized in Table 13, with the pelvic bone divided in four areas. It can be observed a higher occurrence of injury at the posterior arch of the pelvic ring for the test configuration 1. We also observe that more iliac wing injuries occurred in the test configuratio... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What biomechanical factors might contribute to the increased likelihood of pelvic injuries observed at the posterior arch of the pelvic ring in test configuration 1, and how could this information influence the design of protective gear or automotive safety features? |
In the Table 17, the time of fracture, peak strain and drop rate are given for each fractured area of the pelvis as defined in the Method section. The right iliac wing area, which never broke, does not appear in the table. For the areas where two gauges were glued (ilio-pubic rami and iliac wings), only the outputs of ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the method of selecting the outputs of the strongest signal from strain gauges affect the accuracy and reliability of fracture time and peak strain measurements in the ilio-pubic rami and iliac wings for injury biomechanics assessment? |
If we set aside the iliac wing fracture, the PMHS could be gathered in three different groups according to the injury occurrence of the pubic and left sacroiliac areas. Group 1: for two PMHS (MS 685 and MS 695), the pubic area only broke. Group 2: for five PMHS (MS 663, MS 664, MS 691, MS 696 and MS 706), the pubic are... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the sequence of fracture events in the pubic and sacroiliac regions affect the overall stability and mechanical integrity of the pelvis, particularly in the context of differing injury patterns observed in PMHS groups? |
Particular efforts were undertook to optimize the repeatability of the pelvis positioning. The lead sphere helped in that matter. First, it allowed to reduce relatively large bone territories, i.e. the pubic symphysis and the antero-superior iliac spines, to a 3 mm diameter sphere. Always the same operator implanted th... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of lead spheres enhance the precision and accuracy of biomechanical assessments in pelvis injury studies, particularly when dealing with PMHS (Post-Mortem Human Subjects) testing setups? |
Even so, an uncertainty of approximately pmnobreakspace8nobreakspace may exist on the pelvis angles. This uncertainty was estimated by considering the worst case deviation in the positioning. First we assumed that there was possibly a pm5,mathrmmm variation in the location of the spheres within the landmarks. Second, w... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the uncertainty in pelvis angle measurements, compounded by factors such as sphere positioning and segment length deviation, impact the assessment of injury mechanisms and outcomes in biomechanical studies? |
As mentioned in the Result section, less PMHS were injured and with less severity in configuration 3 than in configuration 1. The Table 19 and Table 20 show that the two PMHS samples have equal average BMI and similar average weight and age. The mathrmcmathrmV measured on the ribs was taken as an estimator of the miner... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the measured mineral content of bone, such as the mathrmcV values in PMHS samples, influence the severity and likelihood of injuries in different test configurations? |
Subsets and Splits