content
stringlengths
500
1.99k
filename
stringclasses
5 values
Q
stringlengths
0
342
Part 2 also contained more general considerations of head injury. Specifically, BrIC-based risk curves were used to estimate brain-related injury probabilities, and HIC15-based risk curves from NHTSA were used to estimate boneother injury probabilities. (Those HIC15-based risk curves were shown to yield AvgPctDiff !85 ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the application of BrIC-based risk curves compare to HIC15-based risk curves in estimating brain-related versus bone-related injury probabilities, and what might explain the differences in AvgPctDiff values between these assessment methods?
Part 3 pertained to the consideration of various other candidate brain-injury metrics. Specifically, Parts 1 and 2 were revisited for HIC15, translation acceleration (TA), rotational acceleration (RA), rotational velocity (RV), and a different rotational brain injury criterion from NHTSA (BRIC). The rank-ordered result...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the effectiveness of rotational acceleration (RA) as a brain injury metric compare to other metrics like HIC15 and BRIC in the context of injury assessment and prevention?
The elements of the Pooled Dataset are summarized in Tables A1-A6. For brevity, (a) only unscaled values from the referenced papers are reported in these tables; therein, the cited height and weight were ultimately used to normalize responses via bioscaling equations, when needed; those equations are found at the end o...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the bioscaling equations, detailed at the end of the appendix, assist in normalizing injury responses in relation to height and weight, and why is this normalization important in the assessment of injury biomechanics?
Laituri et al. (2015a) did not report the resultant values for rotational velocity (RV). We approximated them via a regression-based relationship developed from the aforementioned CART simulations. Specifically, linear regression was used to relate RV (true resultant) and an approximated resultant based on the peaks re...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the approximation of rotational velocity using linear regression from peak directional data, as conducted in the Laituri et al. study, impact the accuracy of injury biomechanics assessment, and what might be the implications for evaluating rotational forces in real-world injury scenarios?
Figure A2 depicts the simplified occupantinteriorrestraint model used in the present study. The HIII50, airbag, steering wheel, knee-bolster surface, and seat belt were modeled as fully-deformable parts, and the belt-attachment points and the steering column were modeled with one-dimensional elements. The floor pan was...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the specific modeling choices for fully-deformable and one-dimensional elements in occupant-interior-restraint simulations impact the accuracy and reliability of injury assessments in crash scenarios?
Zou did not report resultant values for translational acceleration (TA) and rotational acceleration (RA). We approximated them via regression-based relationships developed from the aforementioned CART simulations. Specifically, linear regression was used to relate TA (true resultant) and an approximated resultant based...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the approximated values for translational and rotational acceleration, derived from regression-based relationships in CART simulations, influence the assessment of potential injury severity in biomechanical research?
In recent decades high rates of morbidity and deficit have been associated with TBI. In the United States, year 2010, approximately 1.7 million people suffered a TBI and sought medical help. Emergency departments reported 1.4 million TBI treatments including 275,000 hospitalizations and 52,000 deaths. The total estimat...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the primary biomechanical factors that contribute to the high incidence and severity of traumatic brain injuries (TBI) in motor vehicle crashes, and how can these be mitigated through advancements in vehicle safety design?
Biomechanical understanding of TBI is, unfortunately, still at an initial stage. To investigate the relationship between mechanical forces during an impact and the resulting brain injury, finite element (FE) models of the human head have been increasingly used over the past few decades. These mathematical models, which...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can finite element models be further developed to improve the accuracy of predicting specific tissue deformations and pressures associated with traumatic brain injury?
Considering that head injury can be complex with multiple symptoms on intracranial structures, it is necessary to develop a FE model that is able to reproduce the local response of a complete set of experimental settings for the intended use (TBI prediction in the specific case). The benchmark tests should accurately r...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can finite element models be validated to ensure accurate predictions of skull-brain relative displacement, brain deformation, and intracranial pressure across different impact scenarios, such as lateral, frontal, and occipital impacts, when assessing traumatic brain injury (TBI) risk?
The mechanical response of the human brain is better understood as a result of a variety of experimental investigations. In 1977, Nahum et al. (1977) reported the intracranial pressure time recordings from experiments conducted on cadavers where the heads were impacted on the frontal bone by a cylindrical load cell wit...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the variations in linear and angular acceleration measured in cadaver studies contribute to our understanding of brain injury mechanisms, particularly in relation to intracranial pressure changes?
Although experiments on cadavers cannot directly provide injury response data (no injury actually occurs during the experiments), they still importantly contribute to forming knowledge of the human mechanical response of the brain. Work in this area is crucial to support the development of finite element models, which ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the biomechanical research community establish a standardized protocol for selecting cadaveric experiments to ensure unbiased representation of diverse populations in the validation and development of finite element (FE) head models for injury prediction?
In the current study, a reliable head FE model is defined as a model able to reproduce the local response of a representative set of experimental tests for the intended use. For models that aim to predict traumatic brain injury, representative tests include evaluation of intracranial pressure, skull-brain relative disp...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the fidelity of a head finite element (FE) model in replicating experimental intracranial pressure distributions, skull-brain relative displacement, and brain deformation contribute to its effectiveness in predicting and assessing traumatic brain injuries?
The Normalized Integral Square Error (NISE) and the Correlation and Analysis (CORA) were selected to quantitatively compare the predicted time history response to the measured data. A comparison between the two different scoring methods was realized as part of the protocol development. Among other methods, NISE (Donnel...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the adaptations of the Normalized Integral Square Error (NISE) and Correlation and Analysis (CORA) scoring methods enhance the precision of biomechanical injury assessments by better aligning predicted responses with experimental data?
CORA Correlation Rating. CORA was developed by Gehre et al. 2009 and is an objective rating method that combines two independent sub-methods: a corridor rating and a cross-correlation rating. The corridor method calculates the deviation between two curves by means of corridor fitting. Based on experimental results, inn...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the CORA Correlation Rating system contribute to the accuracy and reliability of biomechanical injury assessment models, and what implications does this have for improving safety design standards?
with i representing the i-th experimental test and j representing the mathrmj -th target measurement for a specific experimental test. As first approach, being no corridors available for the collected experimental data (each experimental test was unique), the contribution of the corridor-based method was set to zero (C...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the potential limitations or challenges in using cross-correlation scores with equal weights for amplitude, shape, and phase errors when assessing injury biomechanics in unique experimental tests involving crash test dummies?
The quantitative curve comparison methods NISE and CORA were evaluated on a subset of nine tests including intracranial pressure, relative skull-brain motion and brain deformation data: C241-T5, C241- T6, C288-T3, C064-T4, C380-T4, C380-T5, C380- T6, C393-T3, C393-T4 (Hardy et al. 2007). Four FE head models were select...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the differences in mesh resolution and material properties in the FE head models impact the accuracy of predicting intracranial pressure, skull-brain motion, and brain deformation in quantitative curve comparison methods like NISE and CORA?
1) Royal Institute of Technology (KTH) isotropic model (Figure 2a). This model was developed at the Royal Institute of Technology (KTH) by Kleiven (Kleiven 2007). It consists of 16906 nodes, 11158 hexahedral elements, 10165 shell elements and 22 truss elements. The KTH isotropic model include the scalp, the skull, the ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How might the inclusion of elements such as the scalp, skull, brain, meninges, cerebrospinal fluid, bridging veins, and neck extension in the KTH isotropic model enhance our understanding and assessment of brain injuries resulting from various mechanical impacts?
3) Total Human Model for Safety (THUMS) head model version 4.02 (Figure 2c). The THUMS head model was developed by Toyota Motor Corporation and Toyota Central RD Labs and is an anatomically detailed and highly discretized model of the human head consisting of 24,096 solid, 25,119 shell and 364 seatbelt elements. It inc...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What biomechanical factors and injury criteria can be assessed using the THUMS head model version 4.02 to evaluate head trauma resulting from automotive accidents?
In all thee simulations, translational aaccelerations and rotationall speeds weree applied to a specific noode, which was located att the center oof the head and constraineed to the skulll. In order to iidentify the tarrget positions and extracct characterisstic curves, the dimensionns of the headd models weree scaled ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the scaling of head model dimensions to match experimental post-mortem subjects (PMSHs) impact the accuracy of assessing translational accelerations and rotational speeds applied during head injury simulations?
TTo the best knnowledge of tthe authors, thhree studies hhave reportedd investigatioon of the intracranial ppressure in hhuman specimmens during an impact: NNahum et al. 11977, Trosseillle et al. 19922 and Hardy eet al. 2007. Exxperimental daata from these studies was ccollected and aanalyzed baseed on the a-prriori cr...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the implications of varying impact orientations (sagittal, horizontal, and coronal) on intracranial pressure in human specimens, and how might these influence injury assessment and prediction in biomechanical models?
DDuring the passt decades, thee motion betwween human skull and brainn in an impactt has been investigated by aa research teamm at the Waynne State Univeersity. Three studies reporteed this kind oof data: Al-Bssharat et al. 11999, Hardy et al. 2001 and Hardy eet al. 2007. EExperimental data from theese studies was coll...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the identified measurement errors in horizontal impact kinematics and skull-brain displacement affect the accuracy and reliability of biomechanical models in predicting brain injuries?
OOnly one studdy have reported investigaation of the bbrain deformattion in human specimens duuring a highseverity impacct: Hardy et aal. 2007. Baseed on the appriori criteria reported in ssection 2.1, eexperimental ddata from this study was collected and analyzed. TTable 4 summaarizes the deciision of includding speci...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the implications of including only one horizontal impact in the benchmark set for accurately assessing brain deformation during high-severity impacts, given the noted errors in kinematics and skull-brain displacement tracking?
TThe validationn protocol usees a weightedd averaging pprocedure in oorder to considder different contributions ffrrom the vaarious test conditions and target mmeasurements based on expperimental errror. For the 440 selected exxperimental ccases (Table 2 - 4rangle ) the wweighting facctors for thee test condiitions we...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the weighting factors determined in the validation protocol account for experimental errors in assessing biomechanics-related injury data?
As part of the protocol development, the quantitative curve comparison methods NISE and CORA were evaluated on a subset of nine tests including intracranial pressure, relative skull-brain motion and brain deformation data (C241-T5, C241-T6, C288- T3, C064-T4, C380-T4, C380-T5, C380-T6, C393- T3, C393-T4). The THUMS, GH...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the differences in quantitative curve comparison methods such as NISE and CORA affect the accuracy and reliability of injury predictions in simulations of intracranial pressure, skull-brain motion, and brain deformation, particularly when using varying head finite element models like THUMS, GHBMC, KTH ISO, and K...
To briefly exemplify the responses of the FE head models, Figure 3 illustrates the comparison between the experimental and the simulated intracranial pressure at coup and countercoup locations for the experiments C064-T4, C380-T5, C393-T3 and C393- T4. Figure 4-6 show the comparison between the experimental and the sim...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the comparison of intracranial pressure at coup and countercoup locations in the FE head models contribute to our understanding of brain injury mechanisms and potential thresholds for injury?
Typicallyy, cross correlaation-based sccores were higgher when thee NISE analyysis was impplemented in the validationn protocol thaan the CORAA analysis (Taable 6). A simmilar trend wass found indeppendent of the FE model inn use, the direction of impact or the mechaniccal parameterr in analysiis. The oveerall biofidel...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the variability in biofidelity ratings between the NISE and CORA analysis methods impact the reliability of finite element (FE) models, such as the THUMS and GHBMC head models, in accurately assessing head injury biomechanics?
Analysis by the COORA method mostly showwed inadequaccy in the ddeterminationn of the shhape correlatioon scores of tthe curve. Figgure 9 illustraates exampless of curve comparisonss where shhape correlatioon scores cloose to zero were calculaated between ffairly similar ccurves. CORAA did not idenntify the phasee, amp...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What implications do the inadequacies of the COORA method in accurately determining shape correlation scores have for biomechanical injury assessment and modeling?
Tuning oof the CORA global settinggs was performmed with thee objective to identifyy recommennded parameterrs for usage wwith FE head models. As ffirst the suitabble time intervval of definitiion of the currves was estaablished. Seccondly the shape transittion bbetween ratinggs was calibrrated to matcch the ISO cclassi...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the tuning of CORA global settings, such as the definition of time intervals and calibration of shape transitions, enhance the accuracy of assessing head injury risk in finite element (FE) head models?
Investigations of Intracranial Pressure. Available experimental data by Nahum et al. (1977) have been extensively used for FE model validation. In Nahums experiment a cadaver head was frontally impacted by a cylindrical load cell traveling at a constant velocity. The blow was delivered in the midsagittal plane in an an...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How might the exclusion of rotational kinematics measurements from Nahum's experiment impact the reliability of finite element (FE) models in predicting traumatic brain injuries (TBI) resulting from rotational forces?
Data fromm Trosseille eet al. (1992) inncluded measuures of intracrranial pressuree in the frontall, ventricular, and occipital brain region for heads suubjected to loongduration impacts with high-angularr components. In this seriees of experiiments, post mortem humman subjects ((PMHS) weree hung up in a sitting positt...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How might the accumulation of gases in the intracranial space affect the accuracy of intracranial pressure measurements during the biomechanical assessment of head injuries in PMHS experiments?
HHardy and cowworkers (Harddy et al. 20077) monitored inntracranial ppressure in controlled iimpacts of repressurized inverted humman cadaver head. The specimens werre repressurizeed using artificcial cerebral spinal fluid whhile various levels of linear and angular aacceleration wwere applied too them in diffferent pl...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the implications of measuring intracranial pressure at predicted coup and countercoup locations for understanding brain injury mechanisms in controlled impact experiments?
No air was visible on the test x-rays and the perfusion device was left in operation throughout testing. Given the general accuracy and reproducibility of the data, the occipital impacts C241-T5, C241-T6, C288-T3 and C064-T4, the parietal impact C380-T5 and the temporal impacts C393-T3, C393-T4, C380-T4 and C380-T6 wer...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the accuracy and reproducibility of pressure data acquisition in biomechanical experiments with occipital, parietal, and temporal impacts influence the assessment and understanding of head injury mechanisms?
Investigations of Skull-Brain Relative Motion. The study by Al-Bsharat et al. (1999) is an important pioneer investigation of skull-brain relative motion in humans. In these experiments an impactor delivered controlled blows to the PMHS positioned in an inverted configuration while the displacement between the brain an...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the limited capacity of early high-speed x-ray technology affect the accuracy and comprehensiveness of data regarding skull-brain relative motion during impact in historical biomechanical studies?
The first substantial collection of skull-brain displacement data was published by Hardy et al. in 2001. The experimental setting consisted of controlled impacts onto repressurized inverted human cadaver head. High-speed biplane mathbfX -ray and neutral density targets in columns were used to measure brain displacement...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the implications of utilizing high-resolution X-ray imaging and accelerometer-based kinematic analysis on the accuracy of predicting brain injuries in controlled cadaveric impact experiments?
Some years later, Hardy et al. (2007) extended the investigation by reporting displacement of the brain for new PMHS specimens where NDTs were implanted in clusters instead of columns. The preparation of the specimens was the same as in Hardy et al. (2001) and included repressurization of the head and control mathbfX -...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the biomechanical implications of using clustered NDT (Neutral Density Target) implantation in PMHS (Post Mortem Human Subject) specimens for assessing brain displacement during impact, and how might this method improve our understanding of injury mechanisms?
Investigations of Brain Deformation. Although particularly relevant, available experimental data on brain deformation by Hardy et al. (2007) rarely have been used for FE model validation. In this study brain deformation was calculated from measures of relative skull-brain displacement in controlled impacts of repressur...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do experimental data on brain deformation, such as those provided by Hardy et al. (2007), enhance the validity of finite element (FE) models in assessing traumatic brain injuries resulting from specific types of head impacts?
Data on human brain response in-vivo was collected by Bayly et al. (2005) and Feng et al. (2010) who characterized brain motion using tagged MRI. In these studies volunteer human subjects underwent deceleration of the head on the order of 2-3mathrmg in a MR scan. Although of interest for understanding the in-vivo human...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the limitations in the relevance of mild impact data for understanding traumatic brain injury, as identified in the studies by Bayly et al. (2005) and Feng et al. (2010), inform the development of more effective biomechanical models for predicting injury thresholds in high-impact scenarios?
The intracranial pressure, local brain motion and deformation of brain tissue of the selected PMHS tests described in Hardy et al. (2007) was simulated using the KTH ISO, KTH ANISO, THUMS and GHBMC FE head models. The results of this effort showed the feasibility of assessing the biofidelity of FE head models by using ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the biofidelity of finite element head models, as evaluated through CORA analysis, impact the accuracy of intracranial pressure, brain motion, and tissue deformation assessments in injury biomechanics?
Following the procedure described in Figure 1, NISE was disregarded from the validation protocol. As a matter of fact, the integral method tended to underestimate the amplitude differences between the experimental and model responses and, consequently, over-score in biofidelity. Only very large differences in amplitude...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the limitations observed in the NISE method, such as underestimation of amplitude differences and inadequate time shift identification, impact the accuracy of biomechanical injury assessments, and what improvements could be made to enhance model validation protocols?
1) Perform curve comparison on a fixed time interval The user has to manually ensure that the same time interval is defined for all the curves. The automatic calculation of the time intervals provided by the CORA algorithm (CORA 3.6.1) indeed depends on the shape of the first signal of a load case (or subload case) and...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the manual standardization of time intervals during curve comparison in CORA analysis impact the accuracy and reliability of injury biomechanics assessment when evaluating different finite element head models?
Moreover, it is recommended to cut properly the response curves prior to CORA evaluation, in order to avoid non-relevant parts of a signal to improve or worsen the CORA rating. In Hardys PMHS tests the recording time of experimental signals is much longer than the acceleration pulses (acceleration pulses of 10-15 ms vs...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the appropriate selection of time intervals for response curve analysis, such as 30 ms for intracranial pressure and 40 ms for brain motion and deformation, affect the accuracy and reliability of injury biomechanics assessments in blunt impact scenarios?
A reasonable size of the maximum phase shift has to be identified depending of the shape of the curves. For Hardys data set, the original parameter setting was adequate to identify time shift for pressure responses. However, it was noted that periodic or semi-periodic curves, such as experimental relative displacements...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in the maximum time shift (D_MAX value) influence the accuracy of curve similarity assessments in different biomechanical datasets, particularly when evaluating brain motion and deformation for injury assessment?
For Hardys dataset it was noted that extremely poor shape rating was assigned to fairly similar-shaped curves. This inadequacy of the CORA algorithm was reduced by tuning the shape transition factor and identifying the value leading to the minimization of cases where poor rating was assigned to similar curves. A cubic ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the adjustment of the shape transition factor in the CORA algorithm improve the accuracy and reliability of injury assessment in biomechanical studies?
Finally, the classification of the biofidelity rating in excellent, good, fair, marginal and unacceptable was directly taken from the ISOTR-9770 procedure, where the overall biofidelity rating had a value between 0 and 10. For this standard, the scientific community stipulated that the overall biofidelity value B of a ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the biofidelity rating requirement of at least "fair" for a finite element (FE) head model influence the accuracy and reliability of predicting traumatic brain injuries in side impact scenarios?
A-priori criteria were established to select experimental data for benchmarking to minimize the risk of selection bias (randomization process). A major limitation of this study was the impossibility to reach a complete randomization process due to the paucity of PMHS data. Although a comparable number of horizontal, sa...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the selection bias and age limitation of PMHS (Post Mortem Human Subject) data affect the accuracy and generalizability of biomechanical injury assessment models across different age groups and genders?
Shortcomings in the determination of the model responses resulted from the impossibility to identify with precision the locations of the pressure sensors for the selected tests. Coup and countercoup locations were not described with detail in Hardy et al. 2007, which forced the authors to approximate regions of interes...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How might the precise geometrical identification of pressure sensor locations using CT imaging improve the accuracy and reliability of injury assessment in finite element head models?
Finally, this study describes a method to identify laboratory test procedures and impact response requirements suitable for assessing the biofidelity of FE head models used in prediction of traumatic brain injury. The selection of the experimental data and the response requirements were result of a critical evaluation ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the involvement of the broader scientific community help in establishing a standardized validation protocol for assessing the biofidelity of finite element head models in predicting traumatic brain injury?
This study describes a method to identify laboratory test procedures and impact response requirements suitable for assessing the biofidelity of FE head models used in prediction of traumatic brain injury. The criteria used to select experimental data for benchmarking were accuracy of the experimental protocol, reproduc...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What considerations should be taken into account when determining the weighting factors for different test conditions and target measurements in order to enhance the accuracy of biofidelity assessment in finite element head models predicting traumatic brain injury?
Although finite element (FE) human body models (HBMs) are among the most widely used injury assessment tools, they typically have been constructed to simulate the same body sizes currently represented by physical anthropomorphic test devices (ATDs), in particular the midsize male, small female, and large male. Advances...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can finite element human body models (HBMs) be optimized to better account for the wide range of human variability in terms of anthropometry and injury response beyond the traditional sizes represented by current anthropomorphic test devices (ATDs)?
One of the primary motivations that previous HBM development efforts have used the same body sizes as ATDs is that most crash injury biomechanics data have been generated and analyzed for application to these occupant sizes (and particularly for the midsize male). Thus, the traditional methods to validate HBMs generall...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the integration of rapid mesh morphing methods in the development of subject-specific HBMs improve the accuracy of injury predictions for diverse occupant sizes compared to traditional methods focusing on midsize male ATDs?
The method for developing the P-THUMS has been reported by Hwang et al. (2016) as shown in Figure 1. First, with a given age, sex, stature and BMI, the skeleton (including ribcage, femur, pelvis, and tibia) and external body shape geometries were predicted by the statistical geometry models developed previously (Klein ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the process of morphing the midsize-male THUMS model into target geometries using the RBF morphing method contribute to a more accurate assessment of injury risks across a diverse population with varying anatomical characteristics?
The PMHS test setup is shown in Figure 3. The custom-designed, dual-sled impact facility (Miller et al. 2013) consists of a impact sled 725mathrmkg) and an occupant sled (360mathrmkg) . The impact sled had multiple segmented and padded impact walls with known force-deflection characteristics. A pneumatic accelerator ge...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the force-deflection characteristics of the segmented and padded impact walls in the dual-sled impact facility influence the biomechanical response and potential injury outcomes for occupants during a collision event?
As shown in Table 1, the overweight and normalBMI PMHSs underwent two different crash In the thick-padding condition (overweight PMHS), impact speeds of 3mathrmms and 8;mathrmms were used. Separate impact wall segments were positioned to impact the thorax, abdomen, pelvis-iliac wing, pelvis-greater trocanter, and mid-f...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in impact speeds and wall padding thickness affect the biomechanical response and injury outcomes across different anatomical regions, such as the thorax, abdomen, pelvis, and femur, in overweight versus normal BMI post mortem human subjects (PMHS) during crash tests?
In the thin-padding condition (normal-BMI PMHS), impact speeds of 3,textrmmmathrms and 6mathrmms were used. The impact wall segments were located correponding to the arm, shoulder, thorax, abdomen, pelvis-illiac wing, pelivis-greater trocanter, and mid-femur. The impact walls were positioned such that the contacts betw...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the variation in impact speed (3 m/s vs. 6 m/s) influence the biomechanical injury risks to different body regions such as the thorax and pelvis in normal-BMI post-mortem human subjects (PMHS) under the specified thin-padding condition?
Before the PMHS tests were simulated by the HBMs, an FE model for the dual-sled system, including two sleds, Hexcel between the sleds, impact wall segments, padding on the impact wall, and the seat, was first developed based on the CAD drawings. The model was validated against impact tests with ATDs. The ATD tests were...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the validation of a finite element (FE) model for a dual-sled system with anthropomorphic test devices (ATDs) influence the accuracy of injury biomechanics assessment during post-mortem human surrogate (PMHS) tests in side impact scenarios?
In the thick-padding test condition a SID-HIII dummy (US DOT SID with the head and neck of the HIII- 50mathrmth percentile male test dummy) was tested at 3 mathbfmmathbfs and 8mathrmms , while in the thin-padding test condition a SID-IIs was tested at 3mathrmms and 6mathrmms . A US DOT SID model from LSTC was used to s...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the variation in padding thickness affect the biomechanical response of the SID-HIII and SID-IIs dummies in terms of impact forces and potential injury outcomes at different speeds?
For each of the four PMHS tests (2 padding conditions textbfx2 speeds), three HBMs were simulated for comparison to the test results. These three models are the original THUMS v4 midsize male model (OTHUMS), the parametric THUMS (P-THUMS), and the subject-specific THUMS (S-THUMS). The PTHUMS and S-THUMS were two types ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in the lateral flesh-adipose tissue thickness between the P-THUMS and S-THUMS models impact the accuracy of injury prediction and assessment in post-mortem human surrogate (PMHS) tests under different padding conditions and speeds?
Figure 5 shows the test setups for the two PMHSs along with the corresponding HBM. Because each of the four test conditions (combination of speed and padding) was simulated by three HBMs (O-THUMS, P-THUMS, and S-THUMS), 12 simulations (2 padding conditions textbfX,2 speeds X 3 HBMs) were conducted to compare to the tes...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the differences in weight and stature between the Occupant Total Human Model for Safety (O-THUMS) and the Post-Mortem Human Subjects (PMHSs) impact the accuracy of injury assessment in simulations, and what methods can be used to normalize these variables to improve biomechanical fidelity?
Deformation of the subjects thorax and abdomen was calculated from chest band contours using methods described by Miller et al. (2013) and Wood et al. (2014). Non-deformed (pre-impact) chest contours were obtained for the upper thorax and lower thoraxabdomen using their respective chest band. As illustrated in Figure 6...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What are the implications of normalizing chest-abdomen deflections against initial half-thorax width for accurately assessing thoracic injury risk in biomechanical studies?
Because four parameters were varied, and each parameter has three levels, a full factorial design would result in a total of 81 (mathfrakn34) runs for each PTHUMS. To save the computational time, 27 conditions were selected by Uniform Latin Hypercube Sampling (Table 3). These 27 combinations of material parameters were...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What insights can the comparison of impact force time histories between the modified P-THUMS simulations and PMHS tests provide about the effectiveness of material parameter variations in predicting human injury under high-speed impact conditions?
In the second sensitivity analysis, the occupant posture and boundary conditions were varied with the overweight P-THUMS in the thick-padding crash condition. Table 4 shows the four parameters varied and their levels in the analysis. The occupant posture was adjusted by pm5circ rotations in either the forwardbackward o...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in occupant posture and boundary conditions, such as padding stiffness and abdominal impact wall offsets, influence the biomechanical response and potential injury outcomes in overweight individuals during crash simulations using the P-THUMS model?
Figure 7 shows the comparison between the tests and simulations on the impact sled velocity profile and the forces on four body regions. The US DOT SID model slightly over-estimated the thorax forces in both 3 mathrmms and 8mathrmms tests, while the SID-IIs model slightly over-estimated the pelvis forces and underestim...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What implications do the discrepancies in force estimation by the US DOT SID and SID-IIs models have for assessing injury risk in the thorax and pelvis regions in sled impact scenarios?
Table 6 shows the weights and the mesh quality of the O-THUMS, two morphed P-THUMS and two morphed S-THUMS. Note that the model-predicted weights shown in Table 6 were without any weight adjustment after mesh morphing. Therefore, they are slightly different from the PMHS. For simulation, the weights of the P-THUMS and ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the variability in mesh quality between the P-THUMS and S-THUMS simulations potentially influence the accuracy of biomechanical injury assessment in relation to the O-THUMS standard?
The test and model-predicted impact force time histories in 3mathrm-ms thick-padding condition with overweight PMHS are shown in Figure 11. The test and simulation results in all four testing conditions are provided in Appendix C. The peak values of the impact forces from the tests and simulations are shown in Figure 1...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in BMI affect the accuracy of Human Body Models (HBMs) in predicting impact forces on different body regions during biomechanical testing, and what implications does this have for injury assessment?
The acceleration time histories for each simulation were compared to the PMHS test data as well. Accelerations at T1, T7, L3, S1 vertebrae were measured in the thick-padding condition and were measured at T1, T7, T10, and pelvis in the thinpadding condition. Because multiple peaks were observed in the acceleration time...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can qualitative evaluations of acceleration time histories in different padding conditions improve our understanding of spinal injury mechanisms and potentially inform safety enhancements in simulation models?
The chestabdomen deflections from the tests and simulations using three types of HBMs in the four testing conditions are shown in Figure 13. Compared to the original THUMS, the chestabdomen deflections predicted by the P-THUMS and STHUMS were closer to the test data. While the STHUMS provided the best match to the defl...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the differences in chestabdomen deflection predictions between the O-THUMS, P-THUMS, and STHUMS impact the accuracy of injury risk assessments in crash simulations?
Figures 14 and 15 show the material parameter effects on the peak impact forces based on overweight P-THUMS and normal-BMI P-THUMS, respectively. The mean and standard deviation were expressed as columns and error bars. Generally speaking, the material property effects on peak impact forces were small. For both P-THUMS...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the variation in torso flesh density impact the overall injury risk assessment in overweight versus normal-BMI P-THUMS models, given that it significantly affects peak forces on specific body regions?
Figures 16 and 17 show the material parameter effects on the CORA scores based on overweight PTHUMS and normal-BMI P-THUMS, respectively. Flesh density had more effects on all the peak forces for the overweight P-THUMS than the normal-BMI P-THUMS. The thin flesh layer on the normal-BMI P-THUMS may have reduced the impo...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in flesh density affect the accuracy and predictive capabilities of injury models for different BMI categories, and what implications does this have for developing safety measures for overweight individuals?
Figure 18 shows the peak impact forces in the baseline simulation and 8 conditions specified in Table 5 for the second sensitivity analysis. Leaning closer to the impact wall increased the thorax and abdomen forces, and smaller abdomen offset reduced the abdomen forces substantially, but increased the forces in all the...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do changes in occupant posture, specifically leaning forward, influence the thorax and abdomen impact forces, and what implications does this have for injury assessment and mitigation strategies in automotive crashes?
CORA scores between the responses from the PTHUMS and the O-THUMS, and between the PTHUMS and S-THUMS in the same impact conditions were also calculated. By doing this, the effects from HBM geometry, material property, occupant posture, and impact boundary conditions could be compared directly. All the CORA scores betw...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in geometry, material properties, occupant posture, and impact boundary conditions, as evaluated through CORA scores, influence the accuracy and reliability of injury assessment using different THUMS models in crash simulations?
One of the major contributions of this study is that we compared the impact responses from parametric and subject-specific FE models to those from the PMHS tests. In the past, without mesh morphing methods, such comparison was impractical because a full subject-specific FE model would be required. In that case, the eva...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the integration of parametric and subject-specific finite element (FE) models enhance the accuracy of injury risk assessment for different demographic groups in motor vehicle crashes compared to traditional full subject-specific FE models?
Based on the peak forces on different body regions, the CORA scores for the force time histories, and the maximum thoraxabdomen deflections, the STHUMS generally produced the best correlation to the test results, followed by the P-THUMS. The OTHUMS generally did not correlate as well as the STHUMS and P-THUMS models, e...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the accuracy of anatomical geometry in biomechanical models like P-THUMS and S-THUMS influence the assessment of injury mechanisms and prediction of thorax-abdomen deflection during high-speed impact scenarios?
Two sensitivity analyses were conducted, with the first focused on the HBM material property effects and the second focused on the occupant posture and boundary condition effects on HBM impact responses, especially the impact forces at different body regions. Model-predicted peak values of the impact forces and the COR...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do changes in the material properties of a Human Body Model (HBM) influence the predicted peak impact forces and injury risk in various body regions during side impact conditions?
In Table 8, the lowest average CORA scores for each of the four parameter categories (geometry, material properties, posture, and impact boundary conditions) were highlighted in redbold. Based on the average CORA scores, HBM geometry had the most significant effects on impact forces in side impact conditions, followed ...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in HBM geometry influence side impact injury outcomes compared to changes in occupant posture and impact boundary conditions within the context of injury biomechanics assessment?
However, these results indicated that HBM geometry and pre-impact posture have important effects on occupant impact responses in side impact conditions. A similar finding was also reported by Poulard et al. (2015), in which the effects from pre-impact posture were found to be more important than rib material failure st...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How might the incorporation of detailed three-dimensional pre-impact posture data influence the accuracy of Human Body Model (HBM) simulations in predicting rib fractures during side impacts?
The statistical geometry models used in P-THUMS generate the average size and shape of the whole body and individual anatomical components based on the input variables (in this case sex, age, stature, and BMI). All individuals who match these criteria will differ on all other dimensions, but these deviations will gener...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the use of statistical geometry models like P-THUMS, which account for variables such as sex, age, stature, and BMI, influence the precision of injury assessment when compared to traditional models such as O-THUMS, particularly for individual anatomical components like the ribcage, pelvis, and femur?
Second, in this study, detailed seated posture and body shape data were not available for the PMHS tests used for model evaluation. As a result, the body shape predicted by the statistical body shape model with minor edits in the torso region was used for building the S-THUMS, which was not very different from the P-TH...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do variations in pre-test postures and boundary conditions in PMHS tests influence the accuracy of injury predictions in biomechanical models like S-THUMS compared to P-THUMS?
Third, the accuracy of the parametric HBM relies largely on the quality and posture of the baseline model. The THUMS v4 midsize male model has not been validated previously in the side impact conditions used in this study, thus some assumptions may be inevitably translated to the P-THUMS. For example, the normal-BMI P-...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can improvements in biofidelity of the baseline THUMS v4 model enhance the accuracy of parametric Human Body Models (HBMs) in replicating injury outcomes across different BMI categories during side impact conditions?
Lastly, the padding used in the PMHS tests may complicate the interaction between the PMHS and the impactor. Ideally, the material properties of the padding material should be calibrated using material testing under multiple loading velocities. However, because we cannot find the same padding material for more tests, t...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can variations in the material properties of padding affect the accuracy of simulating human body responses in biomechanical impact tests, specifically regarding the correlation between experimental and computational results for different BMI categories?
In this research study, we evaluated the accuracy of parametric HBMs considering subject-specific anthropometry and skeletal geometry information, and we applied the parametric HBMs in a sensitivity analysis for identifying the most significant parameters on occupant responses in side impact conditions. By comparing to...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the integration of subject-specific anthropometric and skeletal geometry information into parametric Human Body Models (HBMs) improve the accuracy of biomechanical injury assessment in side impact conditions compared to the use of a baseline midsize male HBM?
ABSTRACT To mitigate the societal impact of vehicle crash, researchers are using a variety of tools, including finite element models (FEMs). As part of the Global Human Body Models Consortium (GHBMC) project, comprehensive medical image and anthropometrical data of the 5th percentile female (F05) were acquired for the...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the morphing techniques used in FEMs, such as geometric morphing versus post-hoc scaling, impact the accuracy of injury prediction differences observed in pelvic and rib fractures when simulating vehicle crash scenarios for different body habitus models?
Historically, HBMs are developed to represent an average male (50th percentile in terms of height and weight). There are several reasons for this design paradigm for model development. First, the average male has been used as an indicator for average human response. Therefore, the majority of biomechanics datasets avai...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can injury biomechanics models be adapted to more accurately assess injury risk and outcomes for diverse populations, including variations in gender, age, and body size, given the disproportionate impact of airbag-related injuries on females of below-average height?
Field data has shown that females have a higher risk of sustaining injury during motor vehicle crashes compared to males. For example, Evans et al. found that, for ages 20 to 35, female risk exceeds male risk of suffering a fatal crash in similar severity impacts by 28 (Evans 2001). Similarly, a study of singleoccupanc...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What biomechanical factors might contribute to the observed gender differences in injury severity and fatality risk during motor vehicle crashes, especially for females aged 20 to 35?
However, due to limitations inherent to scaling data from a female body habitus to that of a male, we hypothesize that the most effective technique for validation will be geometrically morphing the F05-O model to the M50 body habitus, rather than applying post-hoc scaling methods to the output data. To date, the data s...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How might the geometric morphing of a finite element model from a female (F05-O) to a male (M50) body habitus improve the accuracy of injury prediction assessments compared to traditional post-hoc scaling methods?
For development of the average male model, the GHBMC established body region model (BRM) centers of expertise (COE) for the development and validation of regional finite element models using CAD geometries developed by the full body model (FBM) COE. These regions were then integrated by the FBM COE for full body valida...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the integration and validation processes of regional finite element models contribute to the accuracy and reliability of injury predictions in the full body model (FBM)?
The thoracoabdominal impact used the same impactor as the chest impact with a nominal velocity of 6.7mathrmms . Following the experimental description, the center of the impactor was aligned 7.5mathrmcm below the xiphoid process at 60circ from the anterior aspect of the body. Model data were filtered using SAE CFC600 (...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What biomechanical factors should be considered when assessing the risk of thoracoabdominal injury during impacts, given the differences in effective mass calculations and stiffness ratio development in comparison to chest impacts?
The lateral shoulder impact, as per Koh et al., was simulated with an impact velocity of 4.5mathrmms using the same impactor applied for the chest and thoracoabdominal impacts. This was a 90circ lateral impact occurring through the head of the humerus. For this study, deflection was normalized by the half bi-acromial w...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the normalization of shoulder deflection by half bi-acromial width improve the accuracy or relevance of biomechanical models in assessing injury risk during lateral shoulder impacts?
A second lateral shoulder impact was performed to simulate the experimental study by Kemper et al (Kemper et al. 2008). In this case, the simulation was conducted to represent the destructive thoracic side impact tests with the arm at 45 degrees. This impact consisted of a 23.4mathrmkg impacting plate .41.5,textrmx,25....
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the model's scaled force and time data, aligned with the impulse momentum analysis and ISO standards, contribute to accurately assessing the risk and severity of thoracic injuries in lateral shoulder impacts?
The lateral pelvis impact used a square-faced impactor weighing 16mathrmkg impacting with 800textbfJ of energy. This required giving the impactor a 10 mathrmms velocity in the lateral direction. The impactor contacted the trochanter and iliac crest at 90 degrees lateral, according to the literature (Bouquet 1998). Pelv...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the use of a 16 kg square-faced impactor with 800 J of energy in lateral pelvis impacts enhance our understanding of injury mechanisms and potential fracture thresholds for different pelvic structures such as the trochanter and iliac crest?
The lateral sled test was modeled as a 6.7mathrmms lateral impact using a Heidelberg-type sled into fixed steel plates (Cavanaugh et al. 1990; Cavanaugh et al. 1993). The impact environment included a flat rigid wall as a backrest, a Teflon seat, and five rigid impacting plates located at the shoulder, thorax, abdomen,...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
What biomechanical parameters are critical to assess when analyzing forces on the torso during a lateral sled test, and how do these parameters inform injury risk and mitigation strategies?
The lateral drop test was simulated to specify a 1 meter free fall onto an instrumented rigid surface (Stalnaker 1979). For this study, contacts were developed to measure the force response of isolated body regions. In this case, the contact force of the torso region was used to assess model response. Model data were f...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the scaling of model force and time signals through the impulse momentum technique, as described by Mertz et al., contribute to the accuracy and applicability of injury assessment in biomechanical simulations like the lateral drop test?
The model was also simulated as a rear seat occupant in a frontal crash pulse as per Michaelson et al. (Michaelson et al. 2008) and Forman et al. (Forman et al. 2009). This simulation represented a 48mathrmkmh frontal impact, which the experimentalists chose to represent the vehicle deceleration experienced by a mid-si...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the use of a force-limiting retractor with pretensioning seat belt mechanism compare to a standard seat belt in terms of biomechanical outcomes and potential injury risks for rear seat occupants during a 48 km/h frontal impact?
Lastly, the frontal sled test was modeled as per data from Shaw et al. (Shaw et al. 2009). This simulation represented a frontal impact pulse with an overall change in velocity of 40mathrmkmh . The boundary condition consisted of a simplified buck modeled as a rigid body with belt properties developed to match experime...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the inclusion or exclusion of pretensioners and load-limiters within the frontal sled test simulation affect the biomechanical response and potential injury outcomes compared to the experimental results using PMHS data from Shaw et al. (2009)?
Following simulation, the ISOTS 18571 standard was used to quantitatively compare the model outputs to experimental time history curves. The standard uses a weighted average of four metrics, corridor, phase, magnitude and slope, to derive a total score describing the fit of data to a reference curve. Based on the algor...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the use of ISOTS 18571 standard metrics, such as corridor and magnitude, contribute to the precision and reliability of injury assessment in biomechanical simulations?
When reporting final quantitative evaluations for validation, researchers commonly report the average of each component rating metric to give a global view of the model response. However, it may be necessary to discriminate between signals of varying magnitude to provide a clearer picture of model behavior. This is par...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the Test Magnitude Factor (TMF) enhance the accuracy of biomechanical model evaluations in injury assessment, particularly when assessing signals of varying magnitudes across different anatomical locations?
In total, 66 scan series were collected across all modalities for a total of 14,170 images. Using this data, 3D CAD geometries were developed for all skeletal structures and each organ that was explicitly modeled. The skeleton consists of 182 individual bones. Explicit representations of 32 organs were developed, encom...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How can the 3D CAD geometries of the 182 skeletal structures and 32 organs be used to improve the accuracy of injury assessment models in predicting injury outcomes for different traumatic scenarios?
The GHBMC F05-O finite element model was developed from the CAD dataset described above. Overall, the F05-O mathrmv2.3 met each of the pre-defined element quality criteria targets and all elements have an initial time step greater than 0.1upmumathrms . Additionally, the percent added mass upon initialization is less th...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the element quality criteria, such as tetra collapse and the Jacobian adherence, influence the accuracy and reliability of the GHBMC F05-O finite element model for predicting injury outcomes in various body regions during a biomechanical assessment?
The use of node-to-node connections and element assignment techniques, where appropriate, significantly reduced the number of required contacts as compared to the GHBMC M50-O model. For example, the femur, quadriceps, hamstrings, and thigh flesh were all developed using a continuous mesh, removing the need for a contac...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the reduction in the number of contacts using node-to-node connections and continuous mesh development in models like F05-O impact the accuracy and reliability of biomechanical injury assessments compared to traditional models like the GHBMC M50-O?
Also, because the morphing process only affects the nodal coordinates of the model, all other model aspects remained identical to the baseline F05-O model. Therefore, the F05-O morphed model contained the same number of nodes, elements, and parts with the same material formulations and contact definitions as the F05-O....
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How does the preservation of mesh quality and element size in the morphed F05-O model influence the accuracy of injury prediction and assessment compared to the original baseline F05-O model?
The model response for each of the localized, rigid impacts can be seen in Figure 8. For each simulation, these figures contain the baseline F05-O model response, the F05-O post-hoc data scaled response, and the F05-O Morphed response. As described above, the baseline F05-O model response was scaled for each of the rig...
2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv
How do the differences between the baseline, post-hoc data scaled, and morphed F05-O model responses, as illustrated in Figure 8, impact the accuracy of injury assessment and the prediction of biomechanical outcomes in various rigid impact scenarios?