content stringlengths 500 1.99k | filename stringclasses 5
values | Q stringlengths 0 342 |
|---|---|---|
Comparisons of the various thoracic IARVs and corresponding regulation limits are given in Table D6. For sternal deflections, the FMVSS 208 limits are quite similar to the IARVs for airbag only restraint. The small differences are due to inconsistencies in rounding of the scale factors. CMVSS 208 specifies limits of 45... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the inconsistencies in scale factor rounding between FMVSS 208 and IARV affect the accuracy and reliability of sternal deflection limits in injury assessment for airbag-only restraint systems? |
For side impact, the injury criteria are the lateral deflection of ribs that protect the liverspleen relative to the lumbar spine, the lateral deflection rate of those ribs, and the internal force between the liverspleen and the lumbar spine. For frontal testing, the injury criteria are the abdominal compression and ra... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the differences in anthropometry and tissue properties among various occupant sizes influence the scaling of IARVs (Injury Assessment Reference Values) for abdominal and thoracic injuries in side and frontal impacts? |
There are four injury criteria that have been used in side impact testing for the pelvis: the pubic symphysis force, the iliac crest force, the sacrum force and the lateral component of the pelvis acceleration. The anthropometry, tissue properties and scale factors for the pelvis are given in Table C6. Table C8 gives t... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in anthropometry, tissue properties, and scale factors for different occupant sizes influence the injury assessment reference values (IARVs) during side impact testing for the pelvis? |
The shoulder has two injury criteria specified for side impact loading: the laterally applied load, and the lateral shoulder deflection relative to the thoracic spine. The anthropometry, tissue properties and scale factors for the shoulder are given in Table C6. IARVs for the midsize male have been proposed (Mertz, 200... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the scaling factors derived from midsize male impact response values (IARVs) improve the accuracy of predicting shoulder injury thresholds for occupants of different sizes during side impact collisions? |
To determine the cause(s) of these fractures, Nyquist and Denton (1978) strain-gauged the tibias of a Hybrid III midsize male dummy to measure loads. Tests were conducted on the 1973 to 1976 GM passenger ACRS using the Hybrid III with the instrumented legs. A moderate collision pulse (18 mph, 10G) was used and only the... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the different leg positioning scenarios in the experiment affect the biomechanical load distribution on the tibia and femur during a moderate collision pulse, and what implications could these findings have for injury assessment and prevention strategies in automotive safety design? |
Mertz (1984) proposed a time-dependent compressive force criterion shown in Figure A3 of Appendix A. This criterion was based on analysis of cadaver data (Patrick et al., 1966, 1967; Powell et al., 1975; Melvin et al., 1975; Yamada, 1970). A value of 7560;mathrmN was chosen as the long duration, constant force level of... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the time-dependent compressive force criterion proposed by Mertz account for the viscoelastic properties of bone, and what implications does this have for assessing injury thresholds in biomechanical studies? |
Note that much of the published cadaver data (Powell et al., 1975; Melvin et al., 1975, 1980; Leung et al., 1983; Cheng et al., 1984; Donnelly et al., 1987; Roberts et al., 1987; Morgan et al., 1989) is for impacts that are distributed across the patella and both femoral condyles; that is, square impacts. In contrast, ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the difference in load distribution between square impacts and impacts involving only the patella and medial femoral condyle, as described in cadaver studies, affect the threshold for fracture forces in knee injuries during automotive collisions? |
Hirsch and Sullivan (1965) have conducted tests on cadaver knee joints where they biased the internal loading of the femoral condyles to either the medial or lateral aspect of the tibial plateau. The IARV of 4000;mathrmN for the internal compressive load on either the medial or lateral aspect of the tibial plateau for ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How might the Internal Axial Resultant Value (IARV) of 4000 N, derived from cadaver studies of the knee joint, influence the design and assessment of knee restraints in automotive safety systems, particularly in preventing fractures during a collision? |
M - The resultant bending moment of mathbfM_mathrmx and My. mathbfM_mathrmx - The bending moment about the neutral axis in the bf X -direction. mathbfM_y The bending moment about the neutral axis in the y-direction. FThe axial compressive force. CThe distance from neutral axis to outermost point of cross-sectional area... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the combination of the bending moments in the X and Y directions (Mx and My) and the axial compressive force (F) influence the likelihood of a bending or compression failure in the tibial shaft, considering the role of the neutral axis and the area moment of inertia? |
The failure bending moments, mathbfM_mathrmc, , and failure axial compressive forces, mathrmF_c , used in the Tibia Index calculations for various size people are given in Table C11. The midsize male failure values proposed by Mertz (1984) were used to calculate the corresponding failure values for the other size peopl... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do variations in the failure bending moments and axial compressive forces, as outlined in Table C11, influence the risk assessment of tibia fractures across different body sizes, using the Tibia Index as a metric? |
The IARV placed on the tibia compressive load (Table C11) will limit the internal compressive load between the tibia and foot at the ankle joint. A second concern is injury due to rotation of the foot relative to the tibia. There are two ways to address the rotation injury concern: 1) place limits on the rotations, or ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | What are the specific biomechanical challenges and methods for assessing the risk of rotational injuries at the ankle joint in the context of tibia-foot interactions, and how do these impact injury risk assessments? |
An alternative to calculating the moment about the ankle joint is to calculate the Tibia Index for the lower tibia load transducer. Since the moment about the ankle joint rises rapidly when the joint stop is contacted, the bending moments mathbfM_y and mathbfM_mathrmx measured at the lower load transducer location also... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the sensitivity of the Tibia Index to rapid changes in bending moments, independent of axial compressive forces, influence the accuracy and reliability of assessing potential ankle joint injuries in biomechanical studies? |
Comparisons between the IARVs and corresponding regulatory limits for the lower extremities are given in Table D8. For femur compression, the Canadian (CMVSS 208) and United States (FMVSS 208) regulations specify the same limits. Both regulate peak femur compressive force of the midsize male and small female. These lim... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the discrepancies between the IARVs and regulatory limits for femur compression in different regions influence the assessment of impact-related lower extremity injuries in car crash scenarios? |
At the meeting, AAMA commented that their IARVs were selected so that if an IARV is not exceeded, the risk of the associated injury would be unlikely for that size person for the simulated accident condition evaluated. To illustrate that point for the Tibia Index, the fracture risk curve for male tibias (ISODTR 7861, 2... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the alteration of the Tibia Index limit to 1.3, instead of adjusting the fracture moment value, impact the accuracy and reliability of injury risk assessment in biomechanical evaluations for midsize males? |
Injury Assessment Reference Values (IARVs) are used by vehicle manufacturers to assess the efficacy of their occupant restraint system designs. These values are selected such that if a given value is not exceeded, then the likelihood of the corresponding injury to that size person in the simulated vehicle collision is ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the selected Injury Assessment Reference Values (IARVs) for neck tension and extension moments contribute to understanding potential injury mechanisms in different sized individuals during simulated vehicle collisions? |
The manufacturers performance goal for a given restraint system design is for the average of the test results to be at or below the IARVs. This connotation is different than the requirement placed on the performance of a restraint system design to meet a regulatory compliance limit. For a FMVSS compliance limit, the ve... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the compliance margin in FMVSS impact the design and biomechanical testing of restraint systems to ensure that occupant injury measures remain below IARVs, and what factors influence the determination of an adequate compliance margin? |
For OOP testing, the compliance limits were set at the IARV levels, Tables D3 and D5. However, in this case, the vehicle manufacturers (AAMA, 1998; Alliance, 1999) requested that the compliance limits for neck tension, extension moment and Nu_mathrmTE be set at low injury risk levels which corresponded to the IARVs to ... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the compliance limits set at Injury Assessment Reference Values (IARVs) for neck tension, extension moment, and Nu_mathrmTE affect the design and effectiveness of airbags in reducing out-of-position (OOP) injury risks? |
A word of caution is needed when using the Tibia Index. The mathbfM_y bending moment must be calculated about the y-axis which is coincident with the ycentroidal axis of the prescribed tibia cross-section. Because of the triangular shapes of the tibial shaft cross-sections, the locus of their centroids in the midsagitt... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do inaccuracies in determining the y-axis moments relative to the centroidal axis of the tibia cross-section impact the reliability of the Tibia Index in assessing lower leg injuries? |
Note that Zuby et al. (2001) have proposed to use the mathbfM_y bending moment calculated about the y-axis that passes through the line connecting the joint centers. They provide the transformation equation for making this calculation using the mathbfM_y moment and the axial force measured by the upper tibia load trans... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the sensitivity of the mathbfM_y moment to axial loading affect the biomechanical accuracy of injury assessments using the Tibia Index in crash testing scenarios? |
Appendix A provides tables that summarize the IARVs for measurements made with the Hybrid III and CRABI families of frontal impact dummies, and for biofidelic child and adult, side impact dummies. In most cases, the injury risk is not known for the IARV, but it is known that all the IARVs are lower bounds of their corr... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How do the scale factors and scaling relationships described in the appendices contribute to the determination of Injury Assessment Reference Values (IARVs) for different dummy sizes and how do these factors ensure accurate injury risk assessment across different anthropometric profiles? |
Papers must be written in an objective, scholarly, and scientific manner, and must be free of commercialism, advertisement, and product identification. All papers must be written according to conventional English usage. Authors whose first language is not English should have their manuscript edited before submission an... | 2016_Stapp Car Crash Journal Volume 60(1)_content_list_text.csv | How does the use of SI units in injury biomechanics research papers influence the precision and consistency of biomechanical data interpretation and injury assessment outcomes? |
The scope of material contained in this journal includes new data on the biomechanics of injury and human tolerance, new methods and tools to study the biomechanics of injury, new developments in occupant protection systems, and new concepts on the biomechanics of injury based on experimental and analytical studies. Pa... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do new methods and tools developed for studying the biomechanics of injury enhance our understanding of human tolerance and improve occupant protection systems? |
ABSTRACT The U.S. has experienced declining crash fatality rates over much of the past three decades. From the early 1990s until the mid-2000s, vehicle design improvements to occupant protection accounted for much of that decline. Now, automakers are poised to contribute even more, utilizing new technology that promis... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical factors should be considered when evaluating the effectiveness of new automated emergency systems in mitigating occupant injuries in remaining crashes? |
There is a paucity of level-wise dynamic stiffness characterization (force vs displacement) data to accurately model the lumbar spine in FEHBM. Moreover, as the field data suggests, lumbar spine fails frequently in compressive loading mode. Therefore, the objective of the present study is to perform dynamic compression... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What are the biomechanical implications of accurately characterizing the dynamic stiffness of lumbar spine motion segments at different loading rates for improving injury prediction and assessment in Finite Element Human Body Models (FEHBM)? |
Muscles and fat tissue were removed from the specimens without damaging the ligaments and intervertebral discs. The lateral and posterior elements were left intact because previous studies have shown them to have a limited effect on axial compressive stiffness under small compressive displacements (Nachemson 1960, Lin,... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the use of acoustic sensors on the vertebral bodies enhance the accuracy and reliability of identifying the temporal onset of injury in biomechanical testing? |
All the compression tests were performed using a hydraulic testing device equipped with a uni-axial piston. The piston was attached to a flat impactingplate (piston plate) on which an accelerometer was mounted. A piston plate 12,textrmm m thick, 120,mathrmmm in length and 90mathrmmm in breadth was constructed of alumin... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the addition of a 90A durometer silicone rubber pad beneath the piston plate influence the accuracy and reliability of biomechanical injury assessment during compression tests, particularly in minimizing the impact of vibrations on data integrity? |
Two simulations were performed using LS-Dyna MPP version 7.0 using 64 cores in the cluster. The First simulation was performed using default lumbar spine stiffness of the GHBMC model, whereas, the second simulation was performed using the mean force versus displacement data obtained from the current study. For each sim... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do variations in lumbar spine stiffness, as modeled in the GHBMC using LS-Dyna, affect the level-wise compressive forces in the simulation and what implications might these variations have for assessing injury risk in real-world scenarios? |
Bi-linearity in the force-displacement curves was observed in both the 0.5 and 1.0;mathrmms tests. The curves followed a similar trend: toe region, linear-region, softening, and failure (Figure 7). Specimens did not soften in non-injurious tests likely due to low impact velocity (0.5mathrmms) and minimal compression (1... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do variations in impact velocity and compression levels influence the stiffness and failure characteristics of biological specimens in force-displacement tests, and what implications might these findings have for understanding injury mechanisms in biomechanical assessments? |
Ash, Lessley et al. (2012) proposed a method in which standard deviations were calculated for both forces and displacements. In this method, for each point on the average curve, plus and minus one standard deviation was calculated for both force and displacement. These four extreme points were used as the end points of... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the method proposed by Ash, Lessley et al. (2012), which involves using standard deviations and force-displacement corridors, improve the accuracy and reliability of biomechanical injury assessments during loading scenarios? |
As indicated in the introductory texts, the objective of the present study is to characterize lumbar spine segments under dynamic compression. Forty six tests were performed using 25 functional spinal units. Different lower spinal levels from T12 to S1 have been tested under compression using a hydraulic testing machin... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical insights can be derived from analyzing the force versus displacement data trends, particularly the transition from the linear region to softening and failure, in lumbar spine segments subjected to dynamic compression? |
In order to validate and test the reliability of the bilinear slope computation, the average force vs displacement response was calculated using the bilinear slope computation algorithm. This bi-linear average force vs displacement data was compared with the average curve calculated from the actual responses (continuou... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the bilinear slope computation method enhance the accuracy of stiffness assessment in both the toe and linear regions, and what implications does this have for understanding injury mechanisms in soft tissue biomechanics? |
The force versus displacement curves showed hysteresis effect upon compressive loading. Intervertebral discs are viscoelastic structures (Virgin 1951, Twomey and Taylor 1982) and majority of the viscoelastic structures exhibited hysteresis phenomenon - a phenomenon in which energy is lost due to internal sliding fricti... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the observed increase in the area of the hysteresis loop during failure loading of intervertebral discs inform us about the extent of structural damage and the potential for long-term injury in human biomechanics? |
The outcome of these tests can be used to both characterize and validate computational models. Typically, lower spines in finite element models are constructed using two methods. In the first method, the vertebral bodies are constructed as deformable structures and adjacent bodies are connected with deformable ligament... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the accuracy of stress versus strain data influence the assessment and prediction of lower spine injuries in osteo-ligamentous computational models, and what are the implications for model validation? |
One of the limitations of the current study is the low number of samples tested at different spinal levels. Future studies, however, should focus on performing more testing to increase the sample size and statistical power of the data at each spinal level. Notwithstanding the relatively limited sample, this work offers... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do variations in padding compression and loading speeds affect the biomechanical response and potential injury outcomes of the lumbar spinal units during impact testing, and what methodologies can be employed to accurately assess these influences? |
ABSTRACT The armies of the North Atlantic Treaty Organization need a shoulder injury criterion for the EuroSID-2re dummy that must be reliable over a large range of loading conditions, from high velocity, short duration impacts (28;mathrmmmathrms-3;mathrmmmathrms) to low velocity long, duration impacts (4mathrmmsmathr... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How can the maximum compression between the acromion and sternum (Cmax) be quantitatively assessed to determine its efficacy as an injury criterion for clavicle fractures in lateral impacts at low velocities within the EuroSID-2re dummy testing framework? |
Though the shoulder force responses were closer to those induced by the high velocity, short duration impacts, the injury patterns resembled those observed for low velocity, long duration loading conditions. Furthermore, the estimated acromion-to-sternum deflection values were not inconsistent with the prediction of th... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical factors might contribute to the similar injury patterns observed in both high velocity, short duration impacts and low velocity, long duration loading conditions on the shoulder? |
The context of this study is the protection of soldiers in armored vehicles subjected to exploding mines or Improvised Explosive Devices (IED). Since the rise of asymmetric conflict, this kind of threat has become a major concern for the armies of the North Atlantic Treaty Organization (NATO). Therefore, since 2001, NA... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the injury criteria derived from automotive crash test dummies need to be adapted or modified to accurately assess the biomechanical impacts and injury mechanisms experienced by soldiers in armored vehicles subjected to explosions from mines and IEDs? |
Indeed, an explosion that occurs in the vicinity of an armored vehicle can induce severe impacts to the occupants in two phases. During the first phase, local deformation of the armored vehicle occurs, causing the lateral panel to bulge inward, toward the occupant. The second phase involves global motion as the whole v... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the distinct kinetic characteristics of the local and global effects during an explosion near an armored vehicle influence the assessment and potential severity of injuries sustained by the occupants? |
The test set-up principle is illustrated in Figure 3. It consisted of a 16mathrm-kg impactor propelled at a 14.3-mathrmmmathrms velocity using bungees. It was in free flight state at the time of shoulder contact. At some point during the impact, the impactor was decelerated by its tail crushing 100-mathrmmm thick block... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the deceleration of a 16 kg impactor, achieved through the crushing of 100 mm thick aluminum honeycomb blocks, affect shoulder injury outcomes in terms of biomechanical response and energy absorption during impact scenarios? |
The PMHS were seated upright on a flat, rigid surface. Their arms were down, alongside the torso, and their hands rested on their laps. The PMHS were placed sideways in front of the impactor and orientated so that the shoulder sustained an impact perpendicular to the bodys sagittal plane 90circ lateral impact). The bod... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the use of a head strap, which maintains the position during a 90-degree lateral impact, potentially affect the kinematic response and subsequent injury patterns observed in the PMHS shoulder and surrounding tissues? |
The position of the subjects along the laboratory Yaxis was adjusted to vary the penetration of the impactor into the shoulder from one test to another. In order to better understand the latter, the impact sequence is further illustrated in Figure 4. For all the tests, the impactor first contacted the shoulder. After a... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does varying the penetration of the impactor into the shoulder affect the biomechanical responses and potential injury outcomes in subjects during controlled laboratory impact tests? |
The PMHS were instrumented similar to Compigne et al. (2004): eight tri-axial accelerometers, series EGAS 500mathrmg , ENTRAN (Les Clayes-sous-Bois, France), on the sternum, both clavicles at proximal and distal sites, both acromions, and T1 vertebra (see Figure 5). Each tri-axial accelerometer was attached to the bone... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How might the placement of accelerometers on different skeletal sites, such as the sternum, clavicles, acromions, and T1 vertebra, impact the accuracy and reliability of biomechanical data collected during crash testing scenarios, particularly in terms of assessing bone stress and potential fracture points? |
The signals were expressed in their local coordinate system with polarities according to the SAE-J211 convention: X forward, Y toward the right, and Z downward. The load sensor signal was positive when compressed and negative when extended and can be regarded as the force applied by the sensor onto the impactors head i... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the utilization of a local coordinate system, as defined by the SAE-J211 convention, enhance the precision in measuring and interpreting biomechanical forces during an impact, and what implications does this have for injury assessment in terms of identifying specific injury mechanisms? |
To get a picture of the impact conditions, the impactor deceleration and velocity time histories are shown for one test (MS01) in Figure 6 and Figure 7 respectively. One can observe a marked change in the slopes of the deceleration and velocity signals at honeycomb contact. For all the tests, the impactor deceleration ... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the absence of pre-crushing in the honeycomb blocks affect the biomechanical accuracy of predicting injury risk based on the peak deceleration observed in the impactor tests? |
The Figure 7 shows the impactor displacement trace for the test MS01 and Table 3 shows the final penetration (or maximum displacement) of the impactor into the shoulder for each test. As expected, two penetration ranges can be seen: 69-72 mathrmmm for the large stand-off values and 56-57ensuremath,mathrmmm for the smal... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What are the potential implications of the observed elastic deformation of the static fixture and impactor shaft on accurate injury assessment and biomechanics modeling in shoulder impact tests? |
As a consequence of DAS malfunctions, some acceleration signals were lost for the tests MS03, MS04, and MS05: all the acromion accelerations are missing and the clavicle accelerations are missing for the tests MS04 and MS05. In addition, because of the sensor detachment during the impact, the acromion acceleration at t... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How might the absence of acromion and clavicle acceleration data in tests MS03, MS04, and MS05 affect the accuracy and reliability of biomechanical injury assessments, particularly in understanding shoulder complex injuries during impacts? |
From Table 6, it can be observed that the highest accelerations were recorded on the impacted side. For the tests MS02 and MS06, the only two for which all accelerations were recorded, the highest peak was recorded at the acromion. At T1 vertebra and at the opposite side, the amount of acceleration dramatically diminis... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the variation in peak acceleration values at different anatomical sites, such as the acromion and T1 vertebra, contribute to understanding the potential risk and severity of shoulder girdle injuries in lateral impact scenarios? |
Figure 13 showed an important difference between the peak accelerations of the impacted side and those of the non-impacted side. It was shown that the peak resultant accelerations of the shoulder girdle dramatically diminished at the non-impacted side after the sternum (Table 6). For the tests MS01, MS03, MS05, which w... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the significant reduction in peak resultant acceleration on the non-impacted side influence the likelihood and severity of injury to the shoulder girdle in collision scenarios? |
The peak sternum accelerations were the same order of magnitude as the clavicle, but the peak T1 accelerations were not. This suggests that the clavicle was the dominant path for the load transmission. Then, we could have expected that a significant amount of acceleration would have been transmitted to the opposite cla... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the mass distribution attached to the sternum influence the biomechanical response and potential injury risk in the shoulder girdle during high-impact events? |
Koh et al. (2005) proposed large acromion-tosternum deflection, causing forward motion of the sternum and rearward motion of the scapula, to explain the resulting clavicle fractures and acromioclavicular ligament tears. It was difficult to establish from the available measurements in the present study if the injuries o... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What improvements in the setup and instrumentation, such as the addition of 3-D motion analysis systems and accelerometers on the scapula, could be made to more accurately correlate observed clavicle fractures and acromioclavicular ligament tears with the specific injury mechanisms described by Koh et al. (2005)? |
The choice of a 16-kg mass of the impactor was a compromise to comply with antagonistic constraints. On the one hand, in order to predict the final penetration into the shoulder, the impactor mass had to be sufficiently high to mitigate the influence of the shoulder on the impactor course; on the other hand, this mass ... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the choice of a 16-kg mass for the impactor affect the biomechanical assessment of shoulder injuries in terms of accurately predicting tissue penetration and deformation, while balancing the resultant deceleration forces on the testing setup? |
Compigne et al. (2004) positioned the subjects so that the load was concentrated on the gleno-humeral joint, i.e. in order to avoid a direct blow onto the acromion. Figures in Compigne et al. (2004) show that the upper edge of the impactor was 15 to 37mathrmmm below the acromioclavicular joint. The acromion peak result... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What implications do the findings from Compigne et al. (2004) have on the understanding of injury mechanisms at the gleno-humeral joint and how can this influence the design of protective equipment to minimize shoulder injuries? |
For the test MS01, which targeted an alignment with the gleno-humeral joint, both impacting cases could have occured. The positioning error when targeting the humerus head or the gleno-humeral joint is greater than when using the acromion as target landmark. In the previous experience of the authors on such shoulder te... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the positioning error when targeting the gleno-humeral joint compared to the acromion influence the accuracy and reliability of biomechanical injury assessments during shoulder impact tests? |
Head halter The strap that maintained the body in an upright position was not released during the impact but the images of the films revealed a very limited lateral motion of the whole body. Indeed, when the course of the impactor ended, the maximum sternum displacement out of the six tests was below 25 mathrmmm (see ... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the tension in the head halter, both before and during impact, influence the biomechanics of sternum displacement and potential injury outcomes in lateral impact scenarios? |
Test protocol The PMHS were impacted twice, once on each shoulder. Despite a precise injury assessment could not be performed after the first test, it was assumed that the injuries found on the firstlyimpacted shoulder was not the result of the second impact performed on the contralateral shoulder. The great differenc... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How might the biomechanical properties of the shoulder complex influence the likelihood of acromioclavicular dislocations and clavicle fractures during initial impact in PMHS tests? |
One could question the influence of these injuries on the response of the secondly-impacted shoulder. Again, as the acceleration pattern of the shoulder girdle suggested that the opposite side barely participated to the body reaction, the presence of injury may not have significantly influenced the shoulder response. T... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the presence or absence of an injury on the firstly impacted shoulder affect the biomechanical response and acceleration patterns of the opposite shoulder in subsequent impacts? |
PMHS, Sample size The findings of this study were limited by the advanced age of the PMHS and their lack of muscle tone. But they were comparable to the studies that also used PMHS. However, no relevant data assessing the bone conditions of the PMHS was available in the present study. It limited the analysis of the in... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the lack of data on the bone conditions of PMHS affect the accuracy and comparability of injury assessment results, and what methods can be employed to overcome this limitation in future studies? |
Six pure lateral impacts were performed on PMHS shoulders at an intermediate loading condition in terms of impact velocity and duration (14mathrmms-9mathrmms) between those of the local effect (28mathrmms-3mathrmms) , and the global effect (4mathrmmmathrmsmathrmmathrm-50mathrmmmathrms) . As far as the shoulder force re... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical factors might contribute to the similarity in injury patterns between high-velocity, short-duration impacts and low-velocity, long-duration impacts on the shoulder, despite differing acceleration profiles and shoulder force reaction responses? |
The Figure 28 shows the shoulder reaction force between -0.8mathrmms and 0.4mathrmms , shifted to the new time 0 (T0) as defined in the Methods section. The former time 0 defined by the contact switch (Tc ) is also shown in Figure 28 and the corresponding shoulder force values are reported in Table 8. Figure 28 and Tab... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical implications could arise from the variability in shoulder force measurements, particularly for tests MS02 and MS05, in accurately assessing injury risk during impact scenarios? |
The impactor set-up was equipped with a device measuring the velocity before impact but this data was lost. The initial velocity could not be acquired via movie tracking because of the low sampling rate (1 frame per millisecond) that induced blurred impactor targets at the beginning of the impact. Consequently, the int... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What potential limitations might arise in accurately assessing injury risk due to the reliance on accelerometer integration for initial velocity determination in the context of the described impactor setup, and how could these affect injury biomechanics analysis? |
However, the tracking of the sternum displacement was used and a procedure was set-up to synchronize the time histories from the measurement and the movie tracking. Not only because the time 0 was redefined for the signals from the sensors (see Appendix 2) but also because the low sampling rate of the movies did not al... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How might inaccuracies in time synchronization between movie tracking and sensor data impact the assessment of sternum displacement and subsequent injury risk in biomechanical studies like the MS04 test? |
The authors know from experience (Lebarbé et al. 2013) that the stand-off computed dynamically from the sensors at the head of the impactor always differs from the stand-off measured prior to the impact. The reasons are numerous but the major one is the high impact speed that induced a significant unphasing between the... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do variations in the material properties and dimensions of an impactor device influence the accuracy of injury assessment data, particularly the deceleration measurements at the impactor's head, and what implications might this have for biomechanical testing and injury thresholds? |
identified using the signal of the impactor load sensor, filtered at CFC 1000. Indeed, the load sensor, which was in compression from the beginning of the impact was suddenly pulled out when the impactor tail contacted the stiff honeycomb. Thus, the first sharp drop on the load sensor signal indicated the action of the... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the timing of honeycomb contact (Th) as determined by the impactor load sensor correlate with the injury risk to the PMHS, and what implications might this have for optimizing impact testing protocols? |
The introduction follows immediately after the abstract. It should provide background on the problem being addressed by the study, including references to relevant literature and the reasons for doing the research. It should also indicate the overall scope of the material covered in the paper, and should briefly indica... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How can biomechanical models be utilized to assess the risk and severity of diffuse axonal injury (DAI) in individuals involved in traffic accidents, assaults, and falls? |
In recent years, finite element (FE) models of the human head including detailed brain structure have been developed as biomechanical approaches, and they are considered to be the most powerful tools for investigating the response of the human head to various impact conditions (Sahoo et al., 2016; Giordano and Kleiven,... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How can finite element models of the human head be utilized to enhance our understanding and assessment of axonal injuries resulting from different impact conditions? |
Until now, numerous in vitro models have been developed, which vary from using dissociated cells (Galbraith et al., 1993; Cullen et al., 2007) to organotypic tissue slices (Cater et al., 2006) and from applying uniaxial (Pfister et al., 2003; Nakadate et al., 2014) to biaxial strains (Nakadate et al., 2012; Sahay et al... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the different in vitro mechanical strain models (uniaxial vs. biaxial) affect the assessment of specific cellular responses and injury cascades, such as changes in calcium levels or electrophysiological responses, in the study of traumatic brain injuries? |
Even though the above-mentioned in vitro models have provided insights toward understanding the cellular mechanism of neuronal injury and suggested that the degree of electrophysiological impairment, morphological damage, and cell death of neurons is directly related to the magnitude and rate of axonal stretch, the exa... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How can the quantification of axonal deformation contribute to predicting secondary degeneration in diffuse axonal injury, and what biomechanical parameters need to be considered for accurate assessment? |
The schematic illustration of the device-loading mechanism is shown in Figure 1(B). A stainless plate connected to the PDMS chamber is pulled by the servo actuator through a wire in the direction of the arrow. The plate is pulled and moved until it hits a stopper. The plate remains at its original position during the a... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | In the context of biomechanics and injury assessment, how might the abrupt stopping of the PDMS chamber at the end of its stretching process, as described in the device-loading mechanism, be used to simulate and analyze soft tissue injury mechanisms in a controlled laboratory setting? |
To orient axons in the direction of stretching, celladhesive line patterns were fabricated on a culture substrate of the PDMS chamber through a microcontact printing method (Kumar et al 1994) for cell adhesion proteins using the procedure shown in Figure 4. Firstly, a microgroove structure for stamping cell adhesion pr... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How might the orientation and alignment of axons, achieved through microcontact-printed cell-adhesive line patterns, influence the mechanical strength and vulnerability to injury under stretching conditions in neurobiomechanical models? |
We subjected cultures with randomly elongated axons to 12 types of stretching, which involved a strain of 0.10 with strain rates of 10, 30, 50, and 70;mathrms-1 , a strain of 0.15 with strain rates of 10, 30, 50, and 70;mathrms-1 , and a strain of 0.20 with strain rates of 10, 30, 50, and 70 mathrms-1 , to investigate ... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the variation in strain and strain rate influence the severity and mechanism of axonal injury in elongated axons, and what implications might these findings have for understanding traumatic brain injury in humans? |
The neurons that matched in age to those subjected to stretching were cultured in the PDMS chamber as sham control, after which they were set in and removed from the uniaxial stretching device without receiving mechanical load. The medium in the PDMS chamber was not removed during the experiment, which was completed wi... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical parameters and methodologies could be employed to accurately assess potential injury or damage to neurons subjected to uniaxial stretching, in contrast to those maintained as sham controls in a PDMS chamber? |
To better understand the effect of axonal strain on axonal injury, we subjected cultures with elongated axons to a strain of 0.22 with a strain rate of 37mathrms-1 and manually counted the number of swellings at each orientation angle relative to the stretching direction. Moreover, to establish an experimental model th... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the orientation angle of axonal swellings relative to the stretching direction influence the severity and pattern of axonal injury under different strain rates? |
A primary effect of the dynamic deformation of axons following stretching is the disruption of axonal transport, resulting in the accumulation of transported materials in the axonal swellings within just a few hours (Smith et al., 1999). The swellings appear at periodic intervals along the connected axons, like beads o... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the accumulation of Tau protein in axonal swellings serve as a biomarker for assessing the severity of axonal injury following dynamic deformation? |
The cultured neurons were stretched with a strain of 0.22 at a strain rate of 37mathrms-1 , and the number of swellings per mm of the axon was calculated manually for each orientation angle of the axon relative to the stretching direction. There was no difference in the number of swellings for each orientation angle be... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the orientation angle of axons relative to the stretching direction influence the extent of axonal swelling observed post-stretching, and what implications might this have for understanding the mechanisms of axonal injury in dynamic loading conditions? |
The orientation angles of 454 neurites cultured by using the directional control technique of axonal elongation, were 9.2circpm3.5 (mean pm mathrmSD ) from the stretching direction, and 56 neurites were oriented at less than 5circ from the stretching direction. The strain in the neurons that have neurites oriented at l... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What implications do the differential strain responses observed in the neurites and cell body, as detailed in the study, have for our understanding of the biomechanics behind neuronal injury mechanisms? |
This study performed stretching experiments on cultured neurons to clarify the relation between axonal deformation and onset of axonal injury. We showed that the strain-rate dependency of axonal tolerance is induced by a higher magnitude of loading strain and the strain along an axon contributes to axonal injury. In ad... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the strain-rate dependency observed in axonal deformation experiments inform the development of improved injury criteria and assessment techniques for axonal injuries in traumatic brain injury (TBI) research? |
The safety design of vehicle rear seat occupants is challenging because of the wide range of occupant sizes and ages that must be considered and protected. Unlike the front seat, which is occupied almost entirely by adults, the rear seat environment must accommodate younger children in child restraint systems with a 5-... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How can advanced restraint systems in vehicle rear seats be designed to dynamically adjust for different occupant sizes and ages, particularly to mitigate head injuries in children and chest injuries in older adults during frontal crashes? |
More recently, Hu et al. (2015) conducted a more comprehensive study using frontal and oblique sled tests to quantify the effects of crash pulse, impact angle, occupant size, front seat location, and restraint system on rear seat occupant impact responses. The results demonstrated the importance of considering the effe... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do occupant size variations and crash pulse characteristics influence the effectiveness of advanced restraint systems in mitigating injury risks for rear seat passengers during frontal and oblique crash scenarios? |
As shown in Figure 1, this study included three series of sled tests and two series of computational simulations focusing on model validation and design optimization. It started with a set of baseline tests to establish the baseline performance of a typical, nonadvanced restraint system in a variety of frontal crash sc... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the baseline and advanced restraint systems differ in terms of their biomechanical impact on occupants of different sizes during frontal crash scenarios, and what injury assessment metrics were used to evaluate these differences? |
A sled buck was built to represent a current compact vehicle. Four ATDs, including THOR-NT 50mathrmth male with the SD3 shoulder, Hybrid-III (HIII) 5mathrmth female, HIII 95mathrmth male and HIII 6 YO were used. In all the sled tests, the lap belt anchorage locations and the Dring location were based on those in the se... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the deformation of vehicle components, such as the sheet metal replacement in the sled buck tests, influence injury risk assessment for different anthropomorphic test devices (ATDs) representing varying occupant sizes? |
Booster seats were not used for the 6 YO ATD in the baseline tests, but were used in all the sled tests with advanced restraint systems. Additional baseline conditions with the 6 YO ATD using booster seats were also conducted in the final sled series to quantify the effects from booster seat on the occupant injury meas... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do booster seats influence injury metrics in a 6-year-old ATD as compared to scenarios where they are not used, and what biomechanical principles can account for these differences in sled tests with advanced restraint systems? |
For the front seat position, the drivers seat was positioned in the mid-track location for all the tests, except for those with the 95mathrmth ATD because 95mathrmth ATD needed larger space to be accommodated. For the 95mathrmth ATD, the drivers seat was positioned such that a 20- mm space was set between the knee and ... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How might the adjustment of the driver's seat position when using a 95th percentile Anthropomorphic Test Device (ATD) impact the assessment of potential knee injuries in frontal crash scenarios? |
Two crash pulses (soft vs. severe) used in this study are shown in Figure 2. The soft pulse was the fleet soft and the severe pulse was the fleet severe based on US NCAP frontal barrier tests. These two pulses were selected by comparing the 2011-2012 BSegment NCAP crash pulses from 25 small cars. The pulse severity ran... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the Occupant Load Criterion (OLC) metric aid in evaluating potential injury outcomes during soft and severe crash pulses in US NCAP frontal barrier tests? |
The restraint components investigated for this study were intended to engage the occupant early in the event and allow the restraint systems to help absorb the energy with a lower load without allowing contact to the front seat. Pre-tensioners were used to engage the occupant early by moving the onset of belt force ear... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do different configurations of pre-tensioners in restraint systems, such as retractor, anchor, and buckle pre-tensioners, affect the biomechanical outcomes and injury risk for occupants in frontal collision scenarios? |
In general once a pre-tensioner fires, the load limiter in the retractor manages belt force to reduce loads on the occupant, potentially allowing the occupant to travel further while absorbing energy. A CLL provides a constant belt force as the webbing is pulled out of the retractor regardless of the occupant size or c... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the variation in belt force application by a Constant Load Limiter (CLL) versus a Progressive Load Limiter (PLL) impact the risk and severity of thoracic injuries in occupants of different sizes during a crash event? |
The DLT is a design consisting of a seat belt tongue (the plate which fastens into the buckle) with a rotating cam and a concealed spring. The DLT allows webbing to pass freely through the tongue when buckling. However, in the event of hard braking or a crash resulting in greater than about 45 mathrmN of force on the b... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the Dynamic Locking Tongue (DLT) mechanism alter the distribution of forces across the chest and pelvis in a crash scenario, and what implications does this have for injury outcomes in vehicle occupants? |
There are limitations in the belt system when trying to balance low belt loads and excursion. One option to mitigate the excursion and allow low belt loads is to incorporate an airbag. Two airbag concepts were investigated in the study. The BiR deploys from the roof of the vehicle between the rear seat occupant and fro... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the differences in inflator output and bag volume between the BiR and SCaRAB airbag systems potentially impact the biomechanics of injury mitigation for rear seat occupants during a collision? |
The test matrices for the second series and the final series with advanced restraint technologies are shown in Tables 3 and 4. The second series focused on testing various combinations of advanced restraints for computer models to validate against, while the final series focused on the optimal restraints with and witho... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the use of advanced restraint technologies, as tested in the second and final series, impact the biomechanical assessment of injury risk in a 6-year-old ATD under both soft and severe crash pulses? |
MADYMO ATD models representing THOR 50mathrmth , HIII 5mathrmth ,95mathrmth and 6 YO ATDs were used in this study. Two THOR 50mathrmth models, a THOR-alpha 50mathrmth and a THOR-NT 50mathrmth model, were used in this study, because the THOR-NT 50mathrmth model developed by TASS became available toward the end of this s... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the differences in geometry and impact characteristics between the THOR-alpha 50th and THOR-NT 50th dummy models affect injury assessment outcomes in sled tests with advanced restraint systems? |
Four sets of environment models were developed along with the ATD models as shown in Figure 4. Simulations were set up to match the baseline test configurations with these 4 sets of models and 2 crash pulses (softsevere). Besides the ATD models, the major components of the crash environment developed in MADYMO were the... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do variations in seat belt anchorage locations and stiffness values of seat components influence the injury outcomes in crash simulations involving Anthropomorphic Test Devices (ATDs)? |
Model parameters optimized in the model validation process against the baseline tests included rear seat parameters (cushion stiffness, damping, and friction), front seat parameters (back stiffness and damping), seat belt parameters (shoulder and lap belt slacks), and ATD parameters (chest and abdomen contact character... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the adjustments in cushion stiffness, damping, and friction of the rear seat parameters influence the injury risk assessment for rear passengers during a collision? |
A total of nine impact responses for each ATD in each test were used for model validation, including the accelerations in X- , and Z-directions at the ATD head center of gravity (CG), chest, and pelvis, as well as chest deflection and shoulder and lap belt loads. In each optimization, the sum of normalized errors of th... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How can the use of equal weights on different types of signals and body regions in the optimization process impact the accuracy of injury prediction models in ATDs? |
Optimization was conducted for each ATD in each of the tests. In each optimization, a total of 200 simulations with different combinations of model parameters sampled by the Uniform Latin Hypercube method were performed first. Response surface models (RSMs) based on radial basis functions were generated to quantify the... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the optimization methods, particularly the use of genetic algorithms like NSGA-II, improve the accuracy and reliability of injury assessment models when applied to Anthropomorphic Test Devices (ATDs) in biomechanical studies? |
Since the ATD model, seat belt model, and the vehicle seat models have been validated at the component level as well as against baseline sled tests, the models with advanced restraints were further validated against the sled tests with advanced restraints. These models included 3-point seat belt with pre-tensioner(s), ... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the integration of advanced restraint systems such as pre-tensioners, load limiters, and dynamic locking tongues into biomechanical models influence the injury assessment outcomes for occupants in different crash scenarios? |
The results of the baseline sled tests have been reported previously (Hu et al. 2015). However, for completeness, the main findings are presented here. Results in the baseline sled series showed that crash pulse and occupant size were the two dominating factors affecting the ATD kinematics and injury measurements, whil... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How does the variation in crash pulse severity influence the kinematic response and injury risk for different sizes of ATDs, and what implications does this have for injury prevention strategies? |
Figure 5 summarizes the CORA evaluation results for each impact response on each ATD, and a summary of the CORA evaluation results are shown in Appendix C. In general, all the models provided good correlations to the test results, although H-III 5mathrmth and 95mathrmth ATD models produced better correlations to the te... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical factors could contribute to the poorer correlation of chest Z accelerations in the ATD models, and how might these factors impact the injury assessment results for different percentile groups, such as the H-III 5th and 95th versus the THOR 50th and H-III 6 YO models? |
The injury measures and ATD kinematics with the 5mathrmth ATD using different restraint systems are shown in Figure 6. Compared to the baseline 3-pt belt system, advanced restraint systems generally reduced the injury measures. However, the 3-point belt with pretensioner and load limiter and the inflatable belt did not... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do the advanced restraint systems, specifically the BiR and SCaRAB, influence the kinematics and injury outcomes of the 5<sup>th</sup> percentile ATD in comparison to traditional 3-point belt systems in crash scenarios? |
H-III 6 YO ATD Test Results The injury measures and ATD kinematics with the 6 YO ATD using different restraint systems are shown in Figure 7. Compared to the baseline 3-pt belt system, advanced restraint systems generally reduced the injury measures. However, none of the advanced restraints reduced all the injury measu... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | How do different restraint systems, such as the 3-point belt with pre-tensioner and load limiter, the inflatable belt, and the 4-point belt, impact neck tension and chest deflection in terms of injury assessment criteria, and why might they fail to meet Injury Assessment Reference Values (IARVs)? |
The injury measures and ATD kinematics with the THOR 50mathrmth using different restraint systems are shown in Figure 8. Compared to the baseline 3-pt belt system, advanced restraint systems generally reduced the injury measures. However, none of the advanced restraints reduced all of the injury measures below the IARV... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical factors could contribute to the THOR 50th chest deflection remaining high despite the use of advanced restraint systems like the 4-point belt and SCaRAB, and how can these systems be optimized to reduce chest injuries effectively? |
The results for the parametric study with 3-point beltonly designs showed that the constraint violations limited the number of designs that can be considered. In particular, only 5 designs were able to meet all the constraints under the soft crash pulse, while no designs could meet all the constraints under the severe ... | 2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv | What biomechanical factors might explain why certain 3-point belt-only designs with a 9.0 or 9.5 mm torsion bar and a buckle pre-tensioner can meet all design constraints under a soft crash pulse but fail under a severe crash pulse? |
Subsets and Splits