content
stringlengths
500
1.99k
filename
stringclasses
5 values
Q
stringlengths
0
342
Overall, the trends presented for the LL09-V2 test condition are representative of the other test configurations where good agreement is observed in the primary, axial response for the CAVEMAN leg with some discrepancies existing in the off-axis loading. For some of the lower rate booted testing (2 mathrmms ), there is...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the discrepancy in off-axis loading affect the overall accuracy of injury prediction in the CAVEMAN leg model, particularly in relation to tibia force measurements during biomechanical testing?
The preliminary analysis of the CAVEMAN lower leg model within the JLTV subsystems is intended for model comparison purposes between the Hybrid III and CAVEMAN systems within a relevant UBB loading environment. The Velodyne simulation was run to 50,mathrmms , as is standard for tactical wheeled vehicle analyses. A depi...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What are the key biomechanical factors that contribute to differences in injury outcomes between the Hybrid III and CAVEMAN lower leg models when subjected to UBB loading environments in tactical wheeled vehicle simulations?
The driver left leg is positioned flat on the floor and sees higher loading than the right leg positioned over the pedal. An investigation into the forces within the driver left leg highlights some differences between the Hybrid III ATD and the CAVEMAN human body model. The loads were obtained through the lower tibia l...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the discrepancies in peak load measurements between the Hybrid III ATD and the CAVEMAN human body model impact the assessment of injury risk for a driver's left leg, and what might these differences suggest about the suitability of each model for evaluating lower limb injuries in automotive crashes?
Stress contours are also presented for the CAVEMAN lower leg skeletal structure. These plots are currently being shown to highlight locations of stress concentrations and the skeletal loading throughout the duration of the event. However, the next step for the CAVEMAN lower leg development process is the detailed inves...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the CAVEMAN system leverage stress and strain data from material failure testing to improve the accuracy of injury predictions for the lower leg skeletal structure?
The effects observed through the material property sensitivity study provide additional insight into the effect of material response to vertically accelerated lower extremity finite element models. As expected, the properties of the muscle-tendon systems do not have a large effect on the transmission of load up the leg...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do variations in ligament material properties influence injury risk and load transmission patterns in vertically accelerated lower extremity finite element models?
Variations in the load transmission through the leg observed in this study may be used to help focus future biological tissue material characterization research for vertical accelerative loading application. The need for improved biological material characterization for human tissues at high strain rates is apparent fo...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What specific material properties of human lower extremity tissues are most critical to focus on for improving the accuracy of biomechanical finite element models, particularly in the context of high strain rate scenarios such as underbody blast events?
The performance evaluation for the CAVEMAN lower leg model utilizes the majority of the data sets generated by the WIAMan lower leg component testing program to date. As with any virtual model, or physical test device, it is important to realize the bounds of this validation effort. The 14 tests employed in this analys...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the limitations in the validation process of the CAVEMAN lower leg model, such as restricted dorsiflexion and plantarflexion angles, impact the accuracy of injury predictions in scenarios outside tested parameters?
Future improvement to the CAVEMAN lower extremity are planned for the remaining bones in the foot which require segmentation into cortical and cancellous regions, evaluation of the knee joint function under accelerative loading and investigation of soft and hard tissue failures. Developments are underway to add orthotr...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the segmentation of foot bones into cortical and cancellous regions influence injury assessment accuracy in the context of accelerative loading biomechanics?
As the WIAMan program begins to move into testing more aggressive loading (higher peak velocities and shorter time to peak) the CAVEMAN model will be continually analyzed via virtual matched pair testing. This will assure that thorough validation documentation exists which can be distributed with the model providing co...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the integration of data from the WIAMan program and previous work at the University of Virginia Center for Applied Biomechanics enhance the validation and reliability of the CAVEMAN model for injury assessment in high-load scenarios?
The demonstration of the CAVEMAN lower leg model within the JLTV subsystem analysis shows some discrepancies between the reported axial forces measurements recorded along the CAVEMAN and Hybrid III lower legs. Although the injury prediction capabilities have not yet been validated for the CAVEMAN leg, and thus have not...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the discrepancies in axial force measurements between the CAVEMAN and Hybrid III lower leg models impact the accuracy of injury predictions in underbody blast scenarios, considering the differences in stiffness response?
CAVEMAN model development was undertaken in an effort to create a virtual human body model to be used for Warfighter injury analysis in a military vehicle subjected to an underbody blast. The complex and chaotic nature of such an event yields an unpredictable environment capable of loading the Warfighter in multiple wa...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the CAVEMAN model be validated against Post-Mortem Human Subject (PMHS) data to ensure its accuracy in predicting Warfighter injuries during underbody blast scenarios in military vehicles?
To date, the CAVEMAN lower extremity model has been compared to the sub-injurious PMHS response to 14 different loading conditions relevant to mounted crew exposure during an underbody blast event. The CAVEMAN lower extremity model performs well in all loading conditions without the need to modify, scale, optimize or t...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the CAVEMAN lower extremity model's current ability to replicate sub-injurious PMHS responses influence its potential to predict skeletal and soft tissue injuries in real-world underbody blast scenarios?
The LL11 test series is a booted, alternate posture lower leg acceleration performed at the Medical College of Wisconsin. The leg is inserted into the test rig with 15circ dorsiflexion. The LL11 test series was conducted early in the WIAMan program before additional load cells were added to the heel and toe; thus, the ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What are the potential implications of using 15-degree dorsiflexion in the LL11 lower leg acceleration test for accurately assessing injury risk in various postures, and how might the lack of heel and toe load cell data affect the interpretation of biomechanical responses?
The LL12 test series is a booted, alternate posture lower leg acceleration performed at the Medical College of Wisconsin. The leg is inserted into the test rig with 20circ plantarflexion. The LL12 test series was conducted early in the WIAMan program before additional load cells were added to the heel and toe; thus, th...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the absence of heel and toe load cell data in the LL12 test series affect the accuracy and reliability of injury assessment in lower leg biomechanics?
The CIS test fixture, Figure 2, was designed in conjunction with the Warrior Injury Assessment Manikin (WIAMan) program to test postmortem human subjects (PMHS) and Hybrid III 50mathrmth percentile male head and neck impact loading. The CIS test fixture established a methodology to perform sub component impact testing ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the use of the CIS test fixture in conjunction with the Warrior Injury Assessment Manikin (WIAMan) program contribute to understanding the biomechanics of head and neck impact injuries in postmortem human subjects (PMHS) compared to the traditional methods involving full-scale blast testing?
Each test asset was fixed to the carriage on the reaction tower, which was placed a designated distance below the simulated roof to the desired helmet to roof clearance. A mass was raised to a designated height on the drop tower to simulate the desired pulse severity and released in free-flight to impact a lever arm th...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What biomechanical injury metrics should be assessed when evaluating the effectiveness of different energy-absorbing materials in reducing head and neck injuries during simulated blast load tests using the described drop tower setup?
The Humanetics model of the Hybrid III 50mathrmth percentile male head and neck was used for this study. The head and neck assembly was instrumented with triaxle accelerometer and ARS at the CG of the head. The upper and lower load cells were also modeled in order to know the forces and moments exerted on the Hybrid II...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the forces and moments recorded by the upper and lower load cells in the Hybrid III head and neck assembly influence the assessment of potential head and neck injuries in scenarios where an advanced combat helmet is worn by the warfighter?
Testing was conducted at the CIS laboratory at SANGB. In order to quantify the injury mechanism due to helmet to roof clearance and neck angle the 3 mathrmms test series was conducted. The compression force data for the upper neck can be seen in Figure 6. For 12.7 mathrmmm of clearance the average compression force was...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does varying helmet-to-roof clearance impact the compressive forces on the upper neck, and what implications does this have for potential neck injuries in vehicular collisions?
Data analysis was conducted on upper neck load cells compression force to analyze how neck angle and helmet to roof clearance impact force and moment in the upper neck. Figure 20 shows the average upper neck compressive force per helmet to roof clearance. The force for all clearances exceed the threshold requirement by...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does varying the helmet to roof clearance impact the compressive force on the upper neck, and what biomechanical implications does this have for injury risk assessment in crash scenarios?
Data analysis was conducted on the upper neck compression force at an impact velocity of 6.6mathrmms .The impact velocity of 6.6;mathrmmmathrms is input velocity found acting on cadaveric cervical spines during UBB events from video tracking of PMHS blast data. Figure 24 illustrates compressive force exerted on the upp...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What implications do compressive forces that exceed the threshold requirement by at least three times have on cervical spine injury risk during UBB events, and how might varying helmet-to-roof clearances affect this risk?
Figure 32 compares the PMHS results from Yoganandan et al. 2016 study to the headneck assembly testing conducted for this study. The helmet to roof clearance are significantly larger than the drop clearance in the study conduct, yet the compressive forces are lower. Test ID 1, 3, 4, 6, and 7 resulted in cervical spine ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do variations in helmet-to-roof clearance versus drop clearance impact the biomechanics of cervical spine fracture occurrences in both PMHS and headneck assembly testing scenarios?
The large compressive injuries witnessed are due to the impact loads of the crown of the head on the roof surface. Bending loads can also be present based upon the initial orientation of the head and neck in addition to the roofs surface friction. The abbreviated injury scores, AIS, for the cervical spine fracture expe...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the initial orientation of the head and neck and the roof’s surface friction contribute to the severity and type of cervical spine injuries observed during the impact, as reflected in the AIS scores?
In lower impact velocity of 3mathrmms , a distinct pattern between helmet to roof clearance and compression force was evident with the smaller helmet to roof clearance experiencing the highest force. The increase of impact velocity is showing that the neck orientation is playing a role in the compressive loading. Exten...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the neck orientation, specifically in terms of extension versus flexion angles, influence the likelihood and severity of compression injuries at different impact velocities?
Neck orientation was not the main parameter to influence the value of HIC, Figure 23. The extension and nominal neck orientation resulted in the same probability of skull fracture and the flexion compressive load was slightly less probable. Although the HIC values greatly exceed the injury criteria, neck angle seems to...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does neck orientation impact the severity of skull fracture risk in comparison to the Head Injury Criterion (HIC) values in various loading conditions?
Figures 33 depict modeling and simulation of the Hybrid III head neck with the same neck angle, -3.6 degrees, and helmet to roof clearance, 12.7 mathrmmm , but different impact velocities, 10,mathrmms and 3,mathrmms . The model shows how the location of head impact and neck angle upon impact differ with the impact velo...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What are the potential biomechanical implications of varying impact velocities on the neck flexion moment during head-neck impacts, and how might this influence injury risk assessment in different scenarios?
The cervical spine compressive forces seen during flexion compression have lower values as compared to the extension compression injuries. The model shows the head being able to escape during the flexion compression loading, this could result in lower comparable compressive forces. The extension neck angle during the v...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the inability of the head to escape during extension compression loading contribute to increased cervical spine compressive forces, and what implications might this have for injury prevention and assessment protocols in biomechanical models?
Common flexion compression injuries that may occur as a result of high vertical loading could be: wedge fracture, facet dislocation, hyperflexion sprain, and teardrop fracture. Yoganandans (Yoganandan et al. 2016) PMHS compressive fractures included spinous process, body, burst, and facet fractures. Fractures were note...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What biomechanical factors could explain the occurrence of cervical vertebrae fractures at impact velocities below established injury criteria, and how might this affect the assessment and prevention of such injuries?
ABSTRACT The objective of this study is to present a quantitative comparison of the biofidelity of the THOR and Hybrid III 50mathrmth percentile male ATDs. Quantitative biofidelity was assessed using NHTSAs Biofidelity Ranking System in a total of 21 test conditions, including impacts to the head, face, neck, upper th...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differences in biofidelity between the THOR and Hybrid III anthropomorphic test devices (ATDs) influence their effectiveness in accurately predicting injury outcomes in various body regions during frontal and frontal oblique restraint loading scenarios?
Biomechanical response requirements have previously been defined and published for the THOR Alpha (GESAC, 2001) and THOR-NT (GESAC, 2005a), and were since updated as part of the Mod Kit design (Ridella and Parent, 2011). These requirements were based, for the most part, on existing post-mortem human surrogate (PMHS) da...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the updated biomechanical response requirement for the THOR compare to the Hybrid III dummy in terms of injury assessment accuracy and biofidelity for frontal impact scenarios?
Throughout several years of use of the THOR Mod Kit and THOR Metric ATDs in component, sled, and vehicle testing, several additional upgrades were implemented to the NHTSA fleet of THORs, which currently consists of 4 Mod Kit and 3 Metric THORs. Two examples are the SD-3 shoulder design, which was added to improve shou...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How have the upgrades to the THOR ATD, specifically the SD-3 shoulder design and the redesigned iliac wing, impacted the accuracy and reliability of biomechanical assessments in vehicle crash tests?
2016a), as much of the testing described herein occurred before the drawing package was published. However, in any test conditions where the differences in design were expected to have an influence on response and the test apparatus was available, the tests were rerun with a THOR-50M matching the August 2016 drawing pa...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do modifications to biomechanical test devices, such as upgrading the iliac wing or using the SD-3 shoulder assembly in the THOR-50M, impact the assessment of biofidelity and the accuracy of injury predictions in crash testing scenarios?
Where possible, ATD test data referred to in this report are available in the NHTSA Biomechanics Test Database (BioDB) available through the NHTSA website (NHTSA, 2017). References to each test include the test reference (TSTREF) and test number (TSTNO) when available, which can be used to download the relevant test da...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the data conditioning process applied to ATD data in order to compare it to PMHS corridors affect the accuracy and reliability of injury assessment in biomechanics studies?
The approach taken in each test condition is described in the relevant sections. If any additional data processing steps such as debiasing, filtering, and phase shifting were applied to the PMHS corridors or individual responses presented in the literature, these steps are noted in the relevant sections; otherwise, dat...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the application of debiasing, filtering, and phase shifting to PMHS corridors or individual responses influence the accuracy and reliability of biomechanical injury assessments?
A total of seven (7) body region groupings were used in this study: head, neck, thorax, abdomen, kneethighhip (KTH), lower extremity (LX), and whole-body. Test conditions grouped into the first six body regions involve component tests which either isolate the body region of interest mechanically, or involve a localized...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the internal and external measurements obtained from the component tests of each body region (head, neck, thorax, abdomen, kneethighhip, and lower extremity) contribute to a comprehensive understanding of injury mechanics and the potential for different injury patterns in sled tests with ATD or PMHS?
To evaluate ATD biofidelity, head drop tests were conducted using both the THOR-50M and H3-50M (Table 2). In each case, the head was dropped from a height of 376 millimeters, resulting in an impact velocity of 2.71 meters per second on a flat plate. The resultant head acceleration was recorded for each ATD. The THOR us...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the BioRank metric help in assessing the biofidelity of THOR-50M and H3-50M anthropomorphic test devices in terms of head impact responses, and what implications does this have for injury prediction and prevention in crash scenarios?
Whole-body Head Impact. The whole-body head impact biomechanical response requirement was derived by Melvin et al. (1988) through an analysis of a combined data set of embalmed and unembalmed PMHS in various impact conditions. This analysis developed the head impact performance requirement for the Advanced Anthropomorp...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the variability in whole-body head impact response, as seen in the differing conditions of embalmed and unembalmed PMHS, affect the reliability and accuracy of the injury assessment using the Advanced Anthropomorphic Test Dummy (AATD) and its successor, the THOR?
To evaluate ATD biofidelity, whole-body head impact tests were conducted using both the THOR-50M and H3-50M (Table 2). In each case, the ATD was impacted with a 23.4 kilogram impactor with a flat disk interface at a velocity of 2.0 meters per second. The impactor acceleration was recorded and multiplied by the impactor...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the single-point BioRank metric provide insight into the relative biofidelity of the THOR-50M and H3-50M anthropomorphic test devices in terms of head impact response compared to the mean peak impact force observed in Post-Mortem Human Subject (PMHS) tests?
To evaluate ATD biofidelity, face rigid bar impact tests were conducted using both the THOR-50M and H3-50M (Table 2). In each case, the ATD was impacted by a 32 kilogram impactor with a 25 millimeter diameter rigid bar interface at a velocity of 3.6 meters per second, the average of the impact velocities in the tests u...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the impact forces measured during the face rigid bar impact tests with the THOR-50M and H3-50M compare, and what implications do these differences have for injury assessment in crash test simulations?
To quantify the biofidelity of the THOR-50M and H3- 50M responses, BioRank was calculated over the time domain of the response corridor. Before BioRank was calculated, the ATD responses were phase-shifted such that the peak force occurred in the temporal center of the defined peak duration (5.9 milliseconds), to be con...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the phase-shifting of ATD responses to align the peak force with the temporal center of the peak duration improve the accuracy of injury assessment in biomechanics experiments?
To evaluate ATD biofidelity, face rigid disk impact tests were conducted using both the THOR-50M and H3-50M (Table 2). In each case, the ATD was impacted by a 13 kilogram impactor with a 152 millimeter diameter flat disk impact surface at a velocity of 6.7 meters per second. The impactor acceleration was recorded and m...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the non-compliance of the THOR-50M SN 9799 with the Face Qualification test procedure impact the accuracy of injury assessments in crash test scenarios involving rigid disk impacts?
Neck Lateral Flexion. The neck lateral flexion biomechanical response requirement was also based on volunteer sled testing conducted by NBDL (Wismans and Spenny, 1983). The data published in this series included 16 tests on 6 volunteers, of which the most severe tests were used to define performance requirements for a ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the kinematic responses of the head, neck, and thoracic spine during neck lateral flexion correlate with potential injury mechanisms and thresholds in sled testing scenarios?
To evaluate ATD biofidelity, the neck lateral flexion test was conducted using the THOR-50M and H3-50M (Table 3). As in the NBDL frontal flexion condition, the sled pulse was applied to the base of the neck. As noted by Wismans and Spenny (1983), the variation in the T1 accelerations did not significantly influence the...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the variability in T1 accelerations influence the accuracy of ATD neck lateral flexion tests in replicating human kinematic responses, and what implications does this have for injury risk assessment in biomechanics?
To compare the THOR-50M and H3-50M responses to the specified response corridors, high-speed video was processed as described in the previous section. However, a discrepancy in timing was identified, as the sled pulse begins at 0 milliseconds (Figure 17) while the T1 pulse does not begin until almost 100 milliseconds (...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differences in timing between the sled and T1 pulses influence the accuracy of injury prediction and biomechanical assessment when using the THOR-50M and H3-50M anthropomorphic test devices?
Parent et al. (2013) evaluated the biofidelity of the H3- 50M and several iterations of the THOR, including the NT, the Mod Kit, and the Metric versions, the latter both with the standard shoulder and with the SD-3 shoulder assembly installed. The configuration described as THOR Metric wSD-3 is functionally equivalent ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the biofidelity characteristics of various THOR dummy configurations, such as the THOR Metric wSD-3, compare to the traditional H3-50M model in simulating thoracic injuries under low-speed impact conditions?
While the Lebarbé corridor was available in the time domain for calculation of BioRank based on force and deflection time-histories, it was necessary to develop force and deflection time-histories representing the Kroell corridor, which existed only as an idealized, linearized response envelop of forces in the deflecti...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the application of a spring-mass-damper system enhance the accuracy and reliability of injury biomechanics assessments when developing force and deflection time-histories for analyzing human body responses in crash scenarios?
Lower Ribcage Oblique Impact. The lower ribcage oblique impact condition is based on PMHS tests carried out by Yoganandan et al. (1997). This condition involves a blunt thoracic impact with a 23.4 kilogram pendulum with a padded 152.4 millimeter diameter disc impacting the approximate level of the eighth rib with the s...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the addition of a foam rubber pad and the oblique impact angle in the lower ribcage oblique impact condition affect the biomechanical response, and what implications might this have for injury assessment and prevention strategies in real-world scenarios?
To recalculate the lower oblique ribcage impact response corridors, the individual force and deflection time-histories were acquired for the first 6 of the 7 subjects described by Yoganandan et al. (1997) (Table 5) and scaled using the mass-scaling approach developed by Eppinger et al. (1984). The force timehistories w...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the construction of force-deflection corridors, with adjusted upper and lower boundaries, impact the accuracy of biomechanical injury assessments in respect to ribcage impacts?
To evaluate ATD biofidelity, upper abdomen impact tests were conducted using both the THOR-50M and H3-50M (Table 6). In each case, the ATD was impacted with an 18mathrmkg pendulum mass with a steering wheel shaped impact interface at a velocity of 8.0mathrmms . The impactor acceleration was recorded and multiplied by t...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the use of time-history and force-deflection corridors in the evaluation of ATD biofidelity enhance the accuracy of injury assessments, particularly in the context of upper abdomen impacts?
To evaluate ATD biofidelity, upper abdomen impact tests were conducted using both the THOR-50M and H3-50M (Table 6). In each case, the ATD was impacted with a 32mathrm-kg pendulum mass with a rigid bar impact interface at a velocity of 6.1mathrmms . The impactor acceleration was recorded and multiplied by the impactor ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the method of calculating impact force through the product of impactor acceleration and mass contribute to assessing the biofidelity of the ATDs in upper abdomen impact tests?
The H3-50M and THOR-NT ATDs were also subjected to this test condition, and found to be excessively stiff compared to the PMHS corridor (Rupp et al., 2003). This was addressed in the Mod Kit update to the THOR with a 57 increase in the length of the compliant element in the femur that allows axial compression (Ridella ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the increase in the length of the compliant element in the femur of the THOR ATD affect its biomechanical similarity to human-like behaviors during axial compression, and what implications might this have for injury assessment accuracy?
The H3-50M knee slider performance requirement is defined in the Hybrid III Users Manual (SAE, 2009), though it is not referenced by NHTSA for either regulation or consumer information testing. This requirement defines an isolated impact test to the knee slider by rigidly supporting the knee assembly and impacting a lo...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the specified reaction force ranges and knee displacements in the H3-50M knee slider performance test contribute to assessing the potential risk of knee injuries in automotive collisions?
More recent biomechanical response data in a similar loading condition presented by Balasubramanian et al. (2004) indicated that the response of the H3-50M at levels of knee displacement below the 10.2 millimeter response requirement was stiffer than the PMHS response. To address this in the THOR-50M, an additional bio...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the modification of the THOR-50M knee displacement measurement to include a 5-millimeter checkpoint with a specified force range influence the accuracy and relevance of biomechanical injury assessments when compared to the prior standard of measuring at 10.2 millimeters?
To develop response corridors suitable for calculation of BioRank, the individual force-displacement responses presented by Balasubramanian et al. (2004) were digitized and a corridor was calculated as described in the reference. This corridor was created using the entire data set (mathrmN14) , as including all subject...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the force-displacement response corridors developed by Balasubramanian et al. (2004) contribute to our understanding of injury mechanisms, particularly in relation to PCL mid-substance ruptures and tibial metaphysis fractures?
To evaluate ATD biofidelity, the knee slider mechanisms of the THOR-50M and H3-50M were subjected to loading from the impact of a 12.0 kilogram pendulum at 2.75 meters per second through a common load distribution bracket. The deflection measured at the knee slider and the reaction force measured at the femur load cell...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the force-deflection characteristic of the knee slider mechanisms in the THOR-50M and H3-50M ATDs compare to the PMHS corridors in terms of biofidelity and injury prediction?
Three test conditions were used to assess biofidelity of the lower leg: heel impact, tibia axial compression, and dorsiflexion. The lower extremity biofidelity assessment is complicated because the foot and shoe of the THOR-50M are integrated, whereas most of the biofidelity response corridors for the human foot were d...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do variations in footwear influence the biofidelity responses of the THOR-50M during heel impact and dorsiflexion testing, and what implications might this have for biomechanical injury assessments?
Tests in an identical test condition were conducted using the H3-50M and presented by Kuppa et al. (1998), though the associated data are not available in the NHTSA Biomechanics Database. Likewise, no THOR-50M data are available in the identical test condition. As an alternative, impact data are available in the qualif...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the absence of identical test condition data for H3-50M and THOR-50M anthropomorphic test devices impact the assessment of lower limb injury biomechanics, and what alternative approaches can be employed to ensure reliable injury assessment?
Since the THOR-50M molded shoe component integrates the foot and shoe into a single response element, correction is necessary before comparing the response to the PMHS corridor. Heel impact tests were conducted according to the THOR-50M Qualification Procedure Manual (NHTSA, 2016b) of the same lower leg with three diff...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the transfer functions developed from the heel impact tests assist in assessing the injury risk and biomechanical fidelity of the THOR-50M molded shoe component compared to traditional shoe and foot configurations?
BioRank was calculated to compare the transferred THOR-50M response and the measured H3-50M response to the four available corridors. As the data associated with the specimens used to calculate the PMHS response corridor were not well-controlled for impact time, the absolute value of the time component of the corridors...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does phase-shifting in aligning ATD responses with PMHS response corridors impact the accuracy of biomechanical injury assessments when using BioRank calculations?
Tests in an identical test condition were not available for the THOR-50M or H3-50M. As an alternative, impact data are available for the THOR-50M in the dynamic dorsiflexion qualification test condition, which consists of a 5.0 kilogram pendulum impact to the ball of the foot in a direction parallel to the long axis of...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the methodology used in the dynamic dorsiflexion qualification test for the THOR-50M dummy help in assessing potential injury mechanisms related to ankle moments during vehicular impacts, and what are the potential limitations of this approach in accurately representing real-world crash scenarios?
Tibia axial compression. Biofidelity of the tibia in axial compression was assessed using the methodology presented by Funk et al. (2000), which represents lower leg loading in an automotive crash environment where the knee is entrapped and the lower leg is compressed due to toepan intrusion. This condition was experim...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the axial compression loading of the tibia, as simulated in the described automotive crash scenario, contribute to the understanding and assessment of potential injury mechanisms in the lower leg during such impacts?
Based on the Funk et al. (2000) data, Lebarbé et al. (2015b) developed response corridors representing tibia axial force as a function of time as well as tibia axial force as a function of footplate displacement. Corridors were developed using 15 of the 20 subjects, excluding 5 which sustained only a tibia fracture. Me...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the exclusion of subjects with only tibia fractures from the development of response corridors impact the assessment of tibial injury biomechanics, and what are the implications for understanding the mechanical thresholds for fracture risk?
Tests in a similar configuration were conducted using two different configurations of the THOR-50M, one with a MIL-spec shoe and one with a prototype molded shoe (Table 11). There were three differences between the tests on the THOR-50M (Kim et al. 2017) and the PMHS tests (Funk et al. 2000): first, the ballistic mass ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differences in footwear configurations, such as MIL-spec shoe versus prototype molded shoe, impact the tibia axial force and injury metrics in the THOR-50M tests compared to PMHS tests?
To evaluate the ATD in its intended application of crash testing in frontal and frontal oblique test modes, biofidelity evaluation in as close to this condition as possible is desired. However, there are many tradeoffs that prevent an exact replication of a motor vehicle crash event in a laboratory environment suitable...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What are the key considerations in balancing the biofidelity of Anthropomorphic Test Devices (ATDs) and the protection of Post-Mortem Human Subjects (PMHS) during frontal and frontal oblique crash testing to ensure reliable and meaningful injury biomechanics data?
Gold Standard 1. The Gold Standard 1 (GS1) sled test condition reported by Shaw et al. (2009) is a simplified representation of a mid-size passenger car crash into a rigid barrier at 40 kilometers per hour. Subjects were positioned on a flat, rigid seat pan and restrained by a shoulder belt and a lap belt with anchor g...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the absence of a load limiter or retractor in the GS1 sled test condition impact the biomechanical assessment of rib cage deformation and potential injury severity in the event of a crash?
The THOR-50M and H3-50M were evaluated in the Gold Standard 1 test condition using the same test apparatus (Table 13). Since 3D motion tracking data was not collected during the evaluation of THOR-50M SN 9207, the data set is supplemented with an earlier data set using a Mod Kit THOR (mathrmSN 016) with the SD-3 should...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the variability in measurement locations between the THOR-50M and H3-50M affect the precision and accuracy of biomechanical injury assessments, particularly regarding chest deflection and spinebox alignment in crash test scenarios?
Far Side Oblique. In most OMDB research crash tests conducted by NHTSA, the far-side occupant was observed to move laterally inboard to the extent that the shoulder belt was no longer in contact with the shoulder at the point of peak forward excursion (Saunders et al., 2015). To gain understanding of the interaction of...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does lateral inboard movement of a far-side occupant during an oblique crash impact the alignment and effectiveness of the shoulder belt, and what implications does this have for the assessment and reduction of thoracic injuries?
The THOR-50M and H3-50M were evaluated in the FSO test condition using the same test apparatus (Table 13). Three different postures and D-ring positions were evaluated for the THOR-50M: Position A, matching the posture and D-ring position in the full-scale vehicle OMDB crash test; Position B, with a posture closest to ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the variations in D-ring positions and postures for the THOR-50M and H3-50M dummies affect the calculated TCBR and overall injury assessment, and what implications might these differences have for the accuracy and relevance of crash test data compared to PMHS testing?
Face Rigid Bar Impact. Qualitatively, the ATD responses were similar in shape to the biofidelity corridor, but higher in magnitude (Figure 6). The BioRank results (Table 14) show that the THOR-50M demonstrates excellent external biofidelity relative to the impact force time-history, but poor external biofidelity consid...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the discrepancy in peak impact force between the THOR-50M and biofidelity corridors affect the accuracy of injury assessment in facial impact scenarios, and what implications does this have for evaluating real-world crash outcomes?
demonstrate excellent external biofidelity for the THOR-50M based on both the impact force timehistory corridor as well as the peak impact force alone. The H3-50M shows good biofidelity in the impact force time-history corridor comparison, but poor biofidelity with respect to the peak impact force alone. The peak impac...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the discrepancy in peak impact force response between the THOR-50M and H3-50M anthropomorphic test devices impact the assessment of injury risk, and what biomechanical factors might contribute to the H3-50M's higher peak force compared to the corridor mean?
The Internal TCBR consists of the deflection timehistory corridor comparison, while the External TCBR consists of the force time-history and force-deflection corridor comparisons. The THOR-50M demonstrates excellent biofidelity based on both the Internal and External TCBR values, while the H3-50M demonstrates marginal ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How might the differences in ribcage deflection measurements between the THOR-50M and H3-50M impact the accuracy of injury risk assessment in frontal crash testing?
Lower Ribcage Oblique Impact. THOR-50M and H3- 50M responses were compared to the deflection timehistory (Figure 26), force time-history (Figure 27), and the two force-deflection corridors developed from the time-history data (Figure 28 and Figure 29). BioRank was calculated for all four comparisons (Table 16). The Bio...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differences in biofidelity scores between the THOR-50M and H3-50M anthropomorphic test devices impact their effectiveness in simulating real-world lower ribcage oblique impacts for injury assessment and prevention?
Upper abdomen steering wheel impact. Both the THOR-50M and H3-50M reach peak deflection earlier in time than the PMHS corridor (Figure 30). The THOR-50M reaches a peak force slightly earlier than the PMHS peak, and this peak exceeds the upper boundary of the PMHS corridor, while the H3-50M peak force occurs slightly la...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
What are the implications of the THOR-50M's and H3-50M's peak force timing and peak deflection behavior in relation to the PMHS corridor for assessing the risk of injury in upper abdomen steering wheel impacts?
Lower abdomen rigid bar impact. Both ATDs exhibit responses that are more stiff than the PMHS corridors, showing higher peak deflections and forces. The THOR-50M response follows the lower boundary of the deflection time-history until it reaches its peak at roughly 120 millimeters of deflection, compared to the peak of...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How might the differences in peak deflections and forces between the ATDs and PMHS corridors influence the assessment of injury risk in lower abdomen impacts?
Femur compression. The deflection of the H3-50M in the femur compression condition is much smaller than that of the THOR-50M (Figure 41), though the peak forces are comparable in magnitude (Figure 42). As a result, the H3-50M femur is much stiffer than the THOR-50M (Figure 43 and Figure 44). Based on the TCBR calculate...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the discrepancy in femur stiffness and biofidelity between the H3-50M and THOR-50M dummies potentially affect the accuracy of injury risk assessment in automotive crash testing?
Knee shear. Comparisons of the THOR-50M and H3- 50M responses to the force-deflection response corridor shows that the response of the THOR-50M is initially less stiff than the corridor, but after about 15 millimeters of compression, the stiffness increases drastically above that of the PMHS corridor (Figure 45). The H...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differing stiffness profiles and external biofidelity of the THOR-50M and H3-50M anthropomorphic test devices affect their ability to accurately predict knee shear injuries in vehicle crash simulations?
While filtering of the response in the foot only configuration is surprisingly effective in predicting the molded shoe response, this approach is unfortunately not uniquely reversible. Instead, a simple scaling approach was implemented to predict the foot only response based on the molded shoe response (Equation 1); wh...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the accuracy of the scaling approach in predicting foot-only responses from molded shoe tests impact the assessment of potential injuries associated with different footwear designs?
The lower tibia force in the foot only configuration demonstrates an earlier initial peak than the foot plus MIL-spec shoe and molded shoe configurations, though this peak is not the overall peak force (Figure 48). The overall peak tibia force occurs at roughly the same time for all three footshoe configurations, and t...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How can the attenuation of impact force by different shoe configurations, such as the foot-only, MIL-spec shoe, and molded shoe, influence the injury risk to the lower tibia during high-impact scenarios?
For the THOR-50M impact response comparisons (Figure 49, Figure 51), the measured force timehistory in the molded shoe condition was corrected based on the transfer functions in Equations 1 and 2, while correction was not necessary for the H3-50M as a shoe was not installed for these tests. The tibia forces The resulti...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the presence of a molded shoe condition in the THOR-50M impact tests influence the internal and external biofidelity in biomechanical injury assessments compared to the H3-50M without a shoe?
Dorsiflexion. Qualitatively, the impact force in the foot only configuration demonstrates an earlier and higher force peak than both shoe configurations (Figure 53), though not as pronounced a difference as in the heel impact condition. When presented with respect to the ankle dorsiflexion angle, the ankle moments of a...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the larger ankle moment and dorsiflexion angle in the foot-only configuration impact the risk of injury compared to wearing either the MIL-spec shoe or molded shoe, and what biomechanical mechanisms contribute to these differences in force and moment distribution?
Using the predicted foot-only response based on the measured response in the molded shoe configuration and the relationship presented in Equations 3, 4, and 5, the THOR-50M shows good agreement with the response corridors for ankle moment time-history (Figure 57) and ankle moment-rotation characteristic (Figure 58). Th...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the internal biofidelity assessment of the THOR-50M's ankle response in dorsiflexion, as indicated by the calculated TCBR, impact its reliability for assessing potential lower extremity injuries in automotive crash scenarios?
Gold Standard 2. Based on the TCBR calculation (Table 20), the THOR-50M internal biofidelity score is slightly better than that of the H3-50M, but the H3- 50M external biofidelity score and classification (good) is better than that of the THOR-50M (marginal). Areas where the H3-50M demonstrates categorically-improved e...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differences in external biofidelity between the THOR-50M and H3-50M anthropomorphic test devices (ATDs), particularly in metrics such as head displacement and shoulder belt forces, influence their use in injury prediction models for automotive safety testing?
There are a few noteworthy findings in the GS3 condition as it relates to injury prediction. First, both ATDs show poor biofidelity with respect to head Zaxis angular velocity. In the PMHS tests, the head naturally rotates about the local Z-axis as it pitches forward about the global Y-axis, perhaps due to the lack of ...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the discrepancy in Z-axis angular velocity between Anthropomorphic Test Devices (ATDs) and Post-Mortem Human Subjects (PMHS) in the GS3 condition impact the accuracy of predicting head and neck injuries in real-world frontal or oblique crash scenarios?
In 7 of the 12 test conditions where internal biofidelity TCBR scores were available for both ATDs, the THOR-50M score was lower than that of the H3-50M. Of the 14 available internal biofidelity scores for the THOR-50M, 4 were classified as excellent and 8 were classified as good. The tibia axial compression response w...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the biofidelity test results and tibia axial compression response of the THOR-50M inform the assessment of lower extremity injury risks compared to when the tibia compressive element in the test bottoms out?
In 11 of the 17 test conditions where external biofidelity TCBR scores were available, the THOR50M score was lower than that of the H3-50M. Of the 17 available external biofidelity scores for the THOR50M, 5 were classified as excellent, 6 good, 5 marginal, and 1 poor. In the lower abdomen rigid bar impact, the THOR-50M...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the variation in stiffness response between the THOR50M and H3-50M in lower abdomen rigid bar impacts affect the accuracy and reliability of injury risk assessments in crash testing simulations?
For each body region, the internal and external TCBR scores were averaged to determine the BRBR (Table 22), which were then averaged to develop overall internal and external BioRank scores for each ATD. Overall, the THOR-50M demonstrates good internal and external biofidelity. The THOR-50M exhibits excellent head and t...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the discrepancies in internal biofidelity scores among different body regions of the THOR-50M and H3-50M impact the accuracy of injury risk predictions in crash test simulations?
Overall, the THOR-50M and H3-50M both demonstrated categorically good internal biofidelity, though the THOR-50M BioRank score was 24 lower (better) than the H3-50M. The intent of the internal biofidelity evaluation is to assess the ability of the ATD itself, not the test apparatus, to collect measurements that are usef...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the capability of the THOR-50M to measure ribcage deformation in multiple directions and locations enhance its predictive accuracy for thoracic and abdominal injuries compared to the H3-50M when used in a vehicle crash test scenario?
Considering external biofidelity, the THOR-50M demonstrated good biofidelity, compared to the poor biofidelity of the H3-50M. Since a majority of the test conditions included involved pure frontal loading, and several involved oblique and lateral loading such as the neck lateral flexion, neck torsion, lower thorax obli...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the superior biofidelity of the THOR-50M anthropomorphic test device contribute to more accurate assessments of injury risk in frontal and frontal oblique crash scenarios compared to the H3-50M, and what implications might this have for developing safety measures in automotive impacts?
Since many of the biomechanical response requirements involve specialized instrumentation or test equipment, these tests are not intended to be carried out as certification or qualification tests conducted between crash tests or sets of crash tests to confirm that specified ATD response requirements are met. Due to the...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differences in response range allowances between qualification specifications and biomechanical response requirements affect the reliability of ATD (Anthropomorphic Test Device) biofidelity in vehicle crash testing?
Where possible, an attempt was made to conduct biofidelity assessment testing of the ATDs in identical test configurations to those used to develop the PMHS response corridors. As this was not always possible due to contractual, financial, and ATD availability limitations, some compromises had to be made. In several te...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the limitations in biofidelity assessment testing of ATDs, such as testing on earlier versions of the THOR, potentially impact the validity and accuracy of injury predictions in crash scenarios?
In other cases, qualification procedures do not exist or are sufficiently different that the performance in the biofidelity test is not directly transferrable. For example, there is no longer an upper abdomen steering wheel impact condition in the THOR-50M qualification procedures (NHTSA, 2016b), thus version equivalen...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the absence of an upper abdomen steering wheel impact condition in the THOR-50M qualification procedures affect the accuracy and reliability of injury biomechanics assessments for that region?
Version equivalence is even more difficult to quantify in the whole-body sled test conditions, where the overall response is a function of the performance of multiple body regions and deformable elements. While some deformable elements of the ATD that may contribute to the response do have performance requirements spec...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the variations in performance requirements for different deformable elements, such as neck flexion versus lumbar spine flex joint, impact the accuracy of injury assessments in whole-body sled tests using ATDs like the THOR-50M?
For the purposes of this analysis, historical PMHS response corridors were not recreated unless doing so was required to create a corridor appropriate for calculation of BioRank which is electronically reproducible and known to represent the mean response plusminus one standard deviation. Where corridors were recreated...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do variations in methods of PMHS response corridor development, such as scaling and subject normalization, affect the accuracy and reliability of biomechanical injury assessments when compared to traditional corridor creation approaches?
One perceived side-effect of not averaging standard deviations is that force-deflection or moment-rotation corridors can have discontinuities where an individual subject has reached peak deflection or rotation, thus the next increment of deflection includes one less observation over which to calculate the standard devi...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the discontinuities observed in force-deflection or moment-rotation corridors, as described in the text, impact the accuracy and reliability of biomechanical models used in injury prediction and assessment?
Throughout this study, THOR-50M and H3-50M were presented in test conditions intended to be the same as the test conditions used in the original PMHS tests used to develop the associated response corridors. There were several limitations preventing the identical test conditions from being recreated, some general and so...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the absence of active musculature and the inability to replicate precise anthropometric positioning when using ATDs like the THOR-50M and H3-50M impact the accuracy and reliability of injury assessment in dynamic loading tests compared to PMHS tests?
To examine this further, simulations were conducted using a finite element model representation of the THOR using either the sled pulse or the T1 pulse input to the base of the neck. While the peak head resultant acceleration was 11 different between the two inputs, the remaining outputs were at most 5.8 different, all...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do the differences in head angle, neck section moment, and X- and Z-axis displacements, when comparing the sled pulse and T1 pulse inputs in finite element models, affect the assessment of potential neck and head injuries in biomechanical studies?
Of the test conditions included in this study, the neck flexion and torsion conditions are the most likely to be influenced by active musculature. In the neck frontal flexion condition, volunteers pre-tensed their muscles (Thunnissen et al., 1995). The response of the THOR50M shows similar x-axis motion (Figure 11) but...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the variation in neck muscle tension states (pre-tensed versus relaxed) in crash test dummies like THOR-50M and H3-50M influence their biomechanical response and accuracy in simulating human neck injuries in frontal, lateral flexion, and torsion conditions during vehicle crash tests?
Abdomen Belt Loading. In the abdomen belt loading tests conducted by Ramachandra et al. (2016), three of the seven subjects were tested twice. For two of these subjects, a previous test was conducted before the Condition A test. This previous test, intended to investigate the influence of pressurization on the force-pe...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the pressurization of abdominal vasculature influence the force-penetration response during abdomen belt loading tests, and what implications does this have for assessing injury biomechanics accurately?
In the PMHS tests, the belt was positioned at the level of the umbilicus. Since neither ATD portrays the anatomical location of the umbilicus, an identical test condition could not be confirmed. Instead, the belt was positioned in a location most likely to result in a successful test execution. For the H3-50M, the belt...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How might the anatomical differences in belt positioning between the PMHS tests and the ATD models affect the accuracy and reliability of biomechanical injury assessments, particularly concerning the abdomen force-deflection response?
Lower Extremity. In two of the lower extremity test modes, heel impact and dorsiflexion, the ATD tests were carried out using a different test configuration than the PMHS tests. Ideally, the exact test procedure would be replicated, but doing so was not possible in this case. Instead, the ATD qualification test data wa...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How do differences in impactor mass and tibia fixation between ATD and PMHS test configurations affect the accuracy and validity of lower extremity injury assessments in biomechanical studies?
In the dorsiflexion condition, the tibia was fixed in both the PMHS tests and the ATD tests. However, the precise input to the PMHS tests is not clear aside from the fact that it was driven by a pneumatic impactor, and that the peak pedal velocity is known for each subject. While an attempt was made to compare THOR-50M...
2017_Stapp Car Crash Journal Vol. 61(1)_content_list_text.csv
How does the variance in input energy between a pendulum impact with an initial velocity of 5.0 m/s and an average pedal velocity of 5.6 m/s affect the biomechanical assessment of tibial injuries in dorsiflexion conditions?