HyPLM_step2 / DATA_CARD.md
ittsleep's picture
Add the L1 structure-label dataset
c0c0325 verified
|
Raw History Blame Contribute Delete
4.1 kB
# Structure dataset for HyPLM stage 2 (v1.0)
Created: 2026-11-17
## What this is
Per-residue structure labels for protein chains, derived from AlphaFold structures and aligned to the chain sequences used in stage 1.
## Columns
| column | type | meaning |
|---|---|---|
| `accession` | string | the UniProt accession the structure came from |
| `sequence` | string | the AFDB label sequence (the AFDB `sequence` field) |
| `length` | int32 | the true chain length; the per-residue columns are padded to the shard size |
| `mask` | bool[L] | keep-mask; False where pLDDT < 70.0 or where the row is padding |
| `ss` | int8[L] | secondary structure: 0 coil, 1 helix, 2 strand; -1 masked |
| `tdi` | int8[L] | 3Di state 0..19; -1 masked |
| `plddt` | float16[L] | per-residue AlphaFold pLDDT |
| `cb_dist` | int8[L*L] | C-beta distance bucket indices, flattened row-major; -1 masked |
## Labels
### Secondary structure
Three states, assigned with biotite's P-SEA implementation (`annotate_sse`), which uses CA coordinates only: `0` coil, `1` helix, `2` strand.
### 3Di
20 states, produced by `foldseek structureto3didescriptor --db-extraction-mode 0` (chain mode, matching the HyPLM paper). The alphabet is `ACDEFGHIKLMNPQRSTVWY`.
### C-beta distance
The pairwise C-beta distance matrix, stored as bucket indices. Glycine has no C-beta, so its C-alpha is used instead. The bucket edges are in Angstrom:
```
0.0, 2.0, 3.0, 4.0, 5.0, 6.0, 6.5, 7.0, 7.5, 8.0, 9.0, 10.0, 12.0, 14.0, 16.0, 20.0, 24.0, 30.0, 40.0, 64.0
```
A bucket index `b` means the distance lies in `[0.0, 2.0)`, `2.0, 3.0)`, and so on. There are 19 buckets, and one edge sits exactly at 8.0 A so that the contact threshold is exactly representable.
**Contact rule**: a residue pair is a contact iff its bucket index is at or below 8 (that is, the distance is below 8.0 A). This is the paper's own definition: contacts are residue pairs whose C-beta atoms are closer than 8.0 A.
## Masking
Masking is at the residue level. A residue whose pLDDT is below 70.0 is masked: its `ss` and `tdi` are -1, and its whole row and column of `cb_dist` are -1. Padding uses the same -1 value, and the `mask` column tells the two apart together with `length`.
## Source and provenance
- Structures: AlphaFold Protein Structure Database (AFDB), model v6
- Sequences: UniRef90 2023 shards (uniref23/shards_out)
- CIF template: `https://alphafold.ebi.ac.uk/files/AF-{accession}-F1-model_v6.cif`
## Leakage removal
Chains matching a test-set sequence with an MMseqs2 E-value at or below 0.001 and a sequence identity at or above 30% are removed whole-chain.
- chains before removal: 38,353
- chains removed: 3,807 (9.93%)
- chains after removal: 34,546
### Test sets
| dataset | version | sequences | fetched | url |
|---|---|---|---|---|
| ProteinGym substitutions reference | 1.3 | 217 | 2026-11-16 | https://zenodo.org/records/15293562/files/DMS_substitutions.csv?download=1 |
| ProteinGym clinical reference | 1.3 | 2525 | 2026-11-16 | https://zenodo.org/records/15293562/files/clinical_substitutions.csv?download=1 |
## Statistics
| metric | value |
|---|---|
| chains | 34,546 |
| shards | 146 |
| size | 1.16 GB |
| length min / median / max | 50 / 273 / 1024 |
| total residues | 10,720,895 |
| kept residues | 9,258,121 (86.4%) |
| pLDDT mean / median | 85.6 / 92.9 |
## Known limitations
- The structures are AlphaFold predictions, not experiments. The pLDDT mask is the only confidence signal; there is no experimental structure channel.
- The label sequence comes from the AFDB `sequence` field, which was built from a 2022 UniProt snapshot, while the sequences themselves come from UniRef90 2023. The two differ for roughly 0.5% of accessions, and those are dropped by the sequence consistency check rather than shipped.
- The secondary structure comes from P-SEA, which differs slightly from the original P-SEA software in some cases.
- The test sets used for leakage removal were collected independently because the paper does not name them, so the leakage filter may be narrower or broader than the paper's own.